Vermeer Southeast Sales DEVELOPMENT ORDER OF THE CITY COMMISSION OF THE
CITY OF BOYNTON BEACH, FLORIDA
PROJECT NAME & ADDRESS: Vermeer Southeast Sales 1060 West Industrial Avenue
APPLICANT'S AGENT: Kenneth Kruger, P.E.
APPLICANT'S ADDRESS: 6792 Red Reef Street Lake Worth, FL. 33467
DATE OF HEARING RATIFICATION BEFORE CITY COMMISSION: August 20, 2002
TYPE OF RELIEF SOUGHT: Request for site plan approval for a 14,222 square foot light
industrial facility in an M-1 zoning district on a 4.32 acre parcel.
LOCATION OF PROPERTY: 1060 West Industrial Avenue
DRAWING(S): SEE EXHIBIT "B" ATTACHED HERETO.
X THIS MATTER came before the City Commission of the City of Boynton Beach, Florida
appearing on the Consent Agenda on the date above. The City Commission hereby adopts the
findings and recommendation of the Planning and Development Board, which Board found as follows:
OR
THIS MATTER came on to be heard before the City Commission of the City of Boynton
Beach, Florida on the date of hearing stated above. The City Commission having considered the
relief sought by the applicant and heard testimony from the applicant, members of city administrative
staff and the public finds as follows:
Application for the relief sought was made by the Applicant in a manner consistent with
the requirements of the City's Land Development Regulations.
The Applicant
~' HAS
HAS NOT
established by substantial competent evidence a basis for the relief requested.
The conditions for development requested by the Applicant, administrative staff, or
suggested by the public and supported by substantial competent evidence are as set
forth on Exhibit "C" with notation "Included".
The Applicant's application for relief is hereby
,,~ GRANTED subject to the conditions referenced in paragraph 3 hereof.
DENIED
5. This Order shall take effect immediately upon issuance by the City Clerk.
6. Ail further development on the prope,,,~,~,,~,~?O~!~//,,///~e made in accordance with the terms
and conditions of this order.
/. utner ______ ~/_._~,' "~-_.'.,_, '~_
DATED:
S:~Planning~S~RED~WP~PROJECTS~Ve~eer South~st SaI~NWSP 02~13~ r~~~er~
Location Map
Vermeer Southeast Sales
EXHIBIT "A"
~-PID
500
o 500
1000 Feet
~o ~J LOTS 6. 7 ~ 8 WEST INDUSTRIAL AVE. ~OYTON BEACH, FLORIDA
HARTER - ADAMS P.A.
ARCHITECTS AND PL~M~INERS
EXHIBIT "B"
LAUREL HILLS - THIRD ADDITION LAUREL HILLS ;- FOURTH ADDITION
SEABOARD COAST LINE (NOW C.S.X.'/ RAILROAD R/W
SEABOARD COAST UNE (NOW C.$.X.) RAILROADR/W
('AS PER R/W &: TRACT MAP
~NIP, IT "B"
WEST INDUSTRIAL AVE.
· [
L_~_~.~~__LJ
(AS PER R/W 8c TRACT MAP
EXHIBIT
; I.m c" .{ _{ ~R - Jkl),d~Nd$ P.A.
EXHIBIT "C"
Conditions of Approval
Project name: Vermeer Southeast Sales
File number: NWSP 02-013
Reference: 2na review plans with a July 23, 2002 Planning & Zoning date stamp marking.
DEPARTMENTS INCLUDE REJECT
PUBLIC WORKS- General
Comments: None X
PUBLIC WORKS- Traffic
Comments:
1. The shared driveway between the noted lots shall be declared in permanent X
agreement(s) for both properties. The agreement(s), at a minimum, shall
define the ownership and maintenance responsibilities of the driveway(s).
Copy(s) of the "Shared Driveway" agreement(s) shall be provided at the time
of permitting.
UTILITIES
Comments:
2. Fire flow calculations will be required demonstrating the City Code X
requirement of 1,500 g.p.m, as stated in the LDR, Chapter 6, Article IV,
Section 16, or the requirement imposed by insurance underwriters, whichever
is greater (see CODE, Section 26-16(a)). In addition, the LDR Chapter 6,
Article IV, Section 16 requires that all points on each building be within 200
feet of an existing or proposed fire hydrant. Please demonstrate that the plan
meets this condition, by showing all hydrants.
FIRE
Comments: None X
POLICE
Comments: None X
ENGINEERING DIVISION
Comments:
3. Explain "South Line Lot 4..." and '2qorth Line Lot 5..." notes shown in X
the interior of Lot 7.
4. Provide all information on the drainage plan in accordance with the LDR, X
Chapter 4, Section 7.F. Inadequate grade information has been provided to
Conditions of Approval
2
DEPARTMENTS INCLUDE REJECT
evaluate flow patterns in the parking lot. At the time of permitting, existing
and proposed grades need to be shown around the site and details provided of
the typical section(s) for the aisles and proposed swales.
5. At time of permitting it may be necessary to replace or relocate large canopy X
trees adjacent to light fixtures to eliminate future shadowing on the parking
surface (LDR, Chapter 23, Article II, Section A.l.b).
6. Landscaped areas shall be protected from vehicular encroachment by a X
continuous, raised curb (LDR, Chapter 7.5, Article II, Section 5.A. and
Chapter 22, Article II, Section E.) At time of permitting.
7. At time of permitting add a note to the landscape plan that within the sight X
triangles there shall be an unobstructed cross-visibility at a level between 2.5
feet and 6 feet above the pavement (LDR, Chapter 7.5, Article II, Section
5.H.).
8. The LDtL Chapter 4, Section 7.C.1 requires the site plan and landscape plan X
to be at the same scale. The preferred scale is 1" = 30'.
9. The note stating that 100% irrigation coverage will be provided conflicts with X
the proposed use of the back of the lot as Open Equipment Storage. Please
resolve conflict at time of permitting.
10. On the site and civil plans, show and identify all necessary traffic control X
devices such as stop bars, stop signs, double yellow lane separators striping,
directional arrows and "Do Not Enter" signage, etc. Delineate and stripe the
"Loading Area" (where applicable - LDR, Chapter 2, Section 11 .J); include a
pavement message in yellow indicating "No Parking - Loading Zone". See
City Standard Drawings B-98001 and B-90013 for striping details. At time of
permitting.
11. At time of permitting provide written and graphic scales on all sheets. X '
12. Placement of fill will require an excavation & fill permit. The excavation & X
fill permit may be obtained prior to final site plan approval through the
Building Department. A surety may be required as a condition of the permit
approval. At time of permitting.
13. A copy of the consumptive use permit (through the SFWMD) will be required X
to be provided during the site permitting process.
BUILDING DIVISION
Comments:
14. Identify the floor elevation that the design professional has established for the X
building within the footprint of the building that is shown on the drawings
titled site plan, floor plan and paving/drainage (civil plans).
I
DEPARTMENTS INCLUDE REJECT
15. At time of permit review, provide a completed and executed City of Boynton
Beach Unity of Title form. The form shall describe all lots, parcels or tracts
combined as one lot. A copy of the recorded deed with legal descriptions, of
each property that is being unified, is required to be submitted to process the
form. The property owner that is identified on each deed shall match.
16. At time of permit review, submit signed and sealed working drawings of the X
proposed construction.
17. At time of permit review, submit for review an addressing plan for the X
project.
18. A recorded copy of the Shared Access Agreement for lots 9 and 6-8, and lots
5 and 6-8 shall be submitted to the Building Division at the time of permit X
application.
PARKS AND RECREATION
Comments: None X
FORE STERfENVIRONMENTALIST
Comments:
19. The applicant must show on the landscape plan the replacement trees for the X
existing 32-inch Ficus tree that will be removed from the site. These
additional native trees should be shown with an appropriate symbol on the
landscape plan.
20. There may exist native scrub habitat along the Eastern property perimeter that X
must be preserved as part of an existing gopher tortoise permit for the site.
The Bahia sod or seed shown on the landscape plan may not be permitted in
conjunction with the gopher tortoise permit. The applicant should address
this with a statement on the landscape plan in consultation with the City
Forester and an environmental consultant for the owner.
PLANNING AND ZONING
Comments:
21. The tabular data on the site plan shall include the maximum height allowed in X
the M1 zoning district.
22. The landscape plan should show the location of all outdoor freestanding X
lighting structures. Provide a detail o£ the proposed outdoor lighting
structure(s), including the dimensions, color, and material. Provide the same
type of information if wall packs are to be used.
23. Landscaping at project entrances shall contain a minimum of one (1) X
"signature tree" on both sides o£the entrances (Chapter 7.5, Article II,
Section 5.N.). Note that signature trees do not contribute toward the total
Conditions of Approval
4
DEPARTMENTS INCLUDE REJECT
number of required perimeter trees or parking area interior landscaping.
Provide one (1) additional signature tree, such as Yellow Elder, Tibouchina
granulose, or Bougainvillea at each side of the project entrance. These
signature trees shall have a minimum of six (6) feet of clear trunk to preserve
the sight area.
24. The landscape buffer adjacent to West Industrial Avenue shall contain X
another layer of plant material. This layer of plant material shall be a
combination of colorful groundcover plants and a minimum of two colorful
shrub species planted in a continuous row.
25. All above ground mechanical equipment such as exterior utility boxes, X
meters, and transformers proposed in front of the building shall be visually
screened (Chapter 9, Section 10.C.4). Equipment placed on the walls of the
building shall be painted to match the building color.
26. Add location of sign to landscape plan and show at base of the monument X
sign enhanced with colorful groundcover plants and a minimum of two (2)
colorful shrub species (Chapter 7.5, Article II, Section 5.0.).
27. Correct inconsistency between pages 1 (Concept Site Plan) and LP-1 X
(Landscape Plan) regarding the footprint/square footage of the proposed
building. Page LP-1 shows a building footprint of 10,000 square feet while
page 1 shows 10,222 square feet.
28. Provide an improved representation of the proposed monument sign with the X
company logo, including the height dimension above grade as well as above
road grade, total signage area and materials / colors which accurately show
the appearance in order to confirm architectural compatibility with the
building. The maximum allowable signage area is 64 square feet on each
side. In addition, clearly identify the site address at the top of the monument
sign.
29. Provide an improved representation of the proposed wall sign along the west X
elevation with calculation methodology, including total signage area and
materials / colors. If more than one logo exist for the company, provide the
details for each logo.
ADDITIONAL COMMUNITY REDEVELOPMENT AGENCY BOARD
CONDITIONS
Comments:
30. Increase that portion of the facade to be covered by block from 2' 8" up X
from grade to 8 feet up from grade
DEPARTMENTS INCLUDE REJECT
ADDITIONAL CITY COMMISSION CONDITIONS
Comments:
1. Omit #30, allowing brick material to be placed along base of facade as X
proposed by applicant.
S:\Planning\SHARED\WP\PROJECTS\Vermeer Southeast Sales\NV~SP 02-013\Condition of Approval 2 page revised 2002 form,doc