Bethesda Physician Parking DEVELOPMF"~T ORDER OF THE CITY COMMIS,~ION OF THE
L., Y OF BOYNTON BEACH, FLORI£
PROJECT NAME: Bethesda Physician Parking
APPLICANT'S AGENT: Jaime Gentile - Kilday & Associates, Inc.
APPLICANT'S ADDRESS: 1551Forum Place Suite 106A West Palm Beach, FL 33401
DATE OF HEARING RATIFICATION BEFORE CITY COMMISSION: February 4, 2003
TYPE OF RELIEF SOUGHT: Request new site plan approval for a 32,058 square foot parking
garage in a PU zoning district on a 1.43 acre parcel.
LOCATION OF PROPERTY: 2700 block of SW 4(h Street Boynton Beach, FL
DRAWING(S): SEE EXHIBIT "B" ATTACHED HERETO.
X THIS MATTER came before the City Commission of the City of Boynton Beach, Florida
appearing on the Consent Agenda on the date above. The City Commission hereby adopts the
findings and recommendation of the Planning and Development Board, which Board found as follows:
OR
THIS MATTER came on to be heard before the City Commission of the City of Boynton
Beach, Florida on the date of hearing stated above. The City Commission having considered the
relief sought by the applicant and heard testimony from the applicant, members of city administrative
staff and the public finds as follows:
Application for the relief sought was made by the Applicant in a manner consistent with
the requirements of the City's Land Development Regulations.
The Applicant
~/HAS
HAS NOT
established by substantial competent evidence a basis for the relief requested.
The conditions for development requested by the Applicant, administrative staff, or
suggested by the public and supported by substantial competent evidence are as set
forth on Exhibit "C" with notation "Included".
The Applicant's application for relief is hereby
&/'GRANTED subject to the conditions referenced in paragraph 3 hereof.
DENIED
5. This Order shall take effect immediately upon issuance by the City Clerk.
All further development on the property shall be made in accordance with the terms
and conditions of this order.
7. Other
~oYNTo~
DATED:
City Clerk
02-011\DO 2003.doc
Location Map
Bethesda Hospital Physician Parking NWSP 02-011
EXHIBIT "A"
PUD
PU
S
C
3OO
600 Feet
SE o"z'rw CT .--
N
Jhl, i I
op
IBIT
o~
City of Boynu~ Be~:h, Flor/da
Bethesda Hospital
Physician Parking
[l!!!.~li ]
EXHIBIT "B'--:-
EXHIBIT '~"
Ii! "'''
Physician Parking
!)
PLAN (NOR T~ BLOG)
EXHIBIT
I
/KCA Design Group, Inc.
K~th D. Clmmbe~, R.A.
~ ~-~'~~'(~I)~15
PLAN (SOUTH BLDG)
BETHESDA HOSPITAL
EXHIBIT!
PHOTO, METRICS
EXHIBIT
l! I' l"J flit'
lID I!iIi: i~.lli !IIi!..ti I
Flit ql. ~?ii l~III
BETHESDA HOSPITAL
Design Group, Inc.
l~~~c~
/:K. zit~D. Chambe~ R.~
BT_,B VA TION$
BETHESDA HOSPITAL
EXHIBIT
EXHIBIT "C"
REVISED Conditions of Approval
Project name: Bethesda Physician Parking
File number: NWSP 02-011
Reference: 3rd Review plans identified as a New Site Plan with a January 17, 2003 Planning & Zoning date
stamp marking.
DEPARTMENTS INCLUDE REJECT
PUBLIC WORKS- General
Comments: None X
PUBLIC WORKS- Traffic
Comments: None X
UTILITIES
Comments: None X
FIRE
Comments:
1. Design documents shall demonstrate compliance with LDR Chapter 6, X
Section 16, which provides requirements for hydrants. Hydrants in
commercial applications shall be no more than 300 feet apart and the remotest
part of any structure shall be no more than 200 feet from a hydrant.
Connections shall be to mains no less than six (6) inches in diameter. In
addition to domestic requirements at a residual pressure of not less than 20
psi, a fire flow of at least 1500 gpm is required.
2. Design documents where underground water mains and hydrants are to be X
provided, must demonstrate that they will be installed, completed, and in
service prior to construction work per the Florida Fire Prevention Code,
(2000) Section 29-2.3.2.
3. City Ordinance Section 9-6, 3./7-11 requires approved automatic fire X
sprinkler systems throughout all buildings or structures regardless of the type
of construction that are in excess of 12,000 square feet per floor.
POLICE
Comments: None X
ENGINEERING DIVISION
Comments: X
Conditions of Approval
2
DEPARTMENTS INCLUDE REJECT
4. Indicate to what standard the project is to be constructed; if the FDOT X
Standard Specifications for Road & Bridge Construction and Standard
Index are to be used - the 2000 Specifications are recommended since they
contain both English and Metric units. Indicate by note at time of
permitting.
5. Add supplemental 4" Solid Yellow Striping (diagonal) at the egress X
driveways from the parking structures into the existing parking lot. The
intent is to provide a visual barrier between the driveway aisle and adjacent
parking spaces in the existing lot.
BUILDING DIVISION
Comments:
6. At time of permit review, provide a completed and executed City of X
Boynton Beach Unity of Title form. The form shall describe all lots, parcels
or tracts combined as one lot. A copy of the recorded deed with legal
descriptions, of each property that is being unified, is required to be
submitted to process the form. The property owner that is identified on each
deed shall match.
7. At time of permit review, submit signed and sealed working drawings of the X
proposed construction.
PARKS AND RECREATION
Comments: None X
FORESTER/ENVIRONMENTALIST
Comments:
8. The applicant must show on the landscape plans all existing trees. Show X
which trees will be preserved, relocated throughout the site or removed and
replaced on the site. These trees should be shown with an appropriate
symbol on the landscape plan.
PLANNING AND ZONING
Comments:
DEPARTMENTS INCLUDE REJECT
9. Provide a unity of title at time of building permit submittal. X
10. Provide building colors by name and manufacturer's number on the X
elevation drawings.
11. Provide a parking space detail drawing on the site plan. X
12. Provide a survey, current within six (6) months at time of building permit X
submittal.
ADDITIONAL PLANNING & DEVELOPMENT BOARD CONDITIONS
Comments:
13. Provide a six-foot masonry wall between the two buildings, set back at least X
10 feet from the west building line (this will replace the vinyl clad chain
link fence as shown on the proposed site plan).
14. No mechanical exhaust equipment may be located on the roofs of the garage X
buildings.
15. Provide the photometric plan to the adjacent residents for their review and X
consent prior to submittal for a building permit.
16. Provide some type of vertical slating on the garage window openings facing X
the "park" area between the two buildings only if they meet Building Code
and Fire Code requirements.
17. Provide more tree variety along the west landscape buffer. X
18. Provide a six foot high masonry wall with a gated access point X
beginning at the southeast corner of the proposed southerly structure
and terminating at the southern property line of Bethesda Memorial
Hospital.
19. Provide a second six foot high masonry wall with a gated access point X
at the northeast corner of the proposed northerly structure and connect
to an existing wall to the north of the subject site.
Conditions of Approval
4
DEPARTMENTS INCLUDE REJECT
ADDITIONAL CITY COMMISSION CONDITIONS
Comments:
1. No mechanical exhaust equipment will be permitted on the project. X
S:\Planning\SHARED\WP\PROJECTS\Bethesda\Physician Parking NWSP 02-01 l\COA.doc