Loading...
Arches (The) DEVELOPMENT ORDER OF THE CITY COMMISSION OF THE CITY OF BOYNTON BEACH, FLORIDA PROJECT NAME · The Arches APPLICANT'S AGENT: Nancy Graham - Urban Principles, LLC APPLICANT'S ADDRESS: 319 Clematis Street Suite 512 West Palm Beach, FL 33401 DATE OF HEARING RATIFICATION BEFORE CITY COMMISSION: May 20, 2003 TYPE OF RELIEF SOUGHT: Request new site plan approval for the construction of a large scale mixed-use development LOCATION OF PROPERTY: Southwest corner of Ocean Avenue and Federal Highway DRAWING(S): SEE EXHIBIT "B" ATTACHED HERETO. X THIS MATTER came before the City Commission of the City of Boynton Beach, Florida appearing on the Consent Agenda on the date above. The City Commission hereby adopts the findings and recommendation of the Planning and Development Board, which Board found as follows: OR THIS MATTER came on to be heard before the City Commission of the City of Boynton Beach, Florida on the date of hearing stated above. The City Commission having considered the relief sought by the applicant and heard testimony from the applicant, members of city administrative staff and the public finds as follows: 1. Application for the relief sought was made by the Applicant in a manner consistent with the requirements of the City's Land Development Regulations. 2. The Appli.cant ~ HAS ~ HAS NOT established by substantial competent evidence a basis for the relief requested. 3. The conditions for development requested by the Applicant, administrative staff, or suggested by the public and supported by substantial competent evidence are as set forth on Exhibit "C" with notation "Included". 4. The Applicant's application for relief is hereby ~ GRANTED subject to the conditions referenced in paragraph 3 hereof. ~ DENIED 5. This Order shall take effect immediately upon issuance by the City Clerk. 6. All further development on the property shall be made in accordance with the terms and conditions of this order. 7. Other DA T E D: -_~_2_~_~_~.~_ S:~Pfar~ninO~HARED~WP~PROJECTS~ARCHES ~ 8B~AI~AN~DO.doc Clerk Location Map EXHIBIT "A" The Arches at Boynton Beach EXHIBIT 'B' " '~ · : · ~ ,~' ..... ~-' .-. ............ ~ ......... ..... '1-'~ I ~ ~ ..... ~.~' - · . t"'"",'"','.',m_~:,'"/ ;'-','-'-/ =~:~'~13~;~ ~ '" ' ~ i .,~:' '/ .' ', ,' '.o-' ,' ;// ' .' , /.' 8 ' ,* ~ ~ ,. , .% ~ ..,...:, ....'..'..:.;.;' .~,'..'...'.. ,,//'/'../ /, ............ ~, I , ~ ,~ -_~!':.,.../,.%}~,,~,,-x..,:..2,,,.,.,.,./, ll~[[~.Lq ....... , ~ --..,,' ...... ".',, , -' .... ; %~'~i~ ~-* "- ,~ ~ , I I--'"-'."."/*~/~'.~'-'...r..'..x.'.'/~ I~ ~ ~ zIJ~l ~ ,. · -~: ~,'~ K.'.$.'.././/'.v/~//..'.z,/'/)'.C/://3~' si o~'~ .~,-' -- ~ '.., .c_ ' · , ,~,..~_ ~.,~_,~ .,~ , ,~. , z' x_.,, ,' ,, .,r z~Ez' /., , /'~. I .. - { ! "'"~'./;2'-' ~,. , . ~, : : ~- 8r.,.,.,:,.,z,.,.~.....,/,..:.,.,~ ~ ~ " ~II' "? ~ .-~: L [ .... -:, '*.1..'.'.'.;. :~. /...'/ , ~.,,,. ,.... ~. ~ . , ~,~Z,~';:~',,',-~' i , r~ ~. THE ARCHES AT BOYNTON BEACH [ i J ~j,.j..~j~ Sj..[~[.[ Jo,,~*-~,~ J ..... ""~'/' ...... 1 -JBOUNO^RY AND TOPOGRAPMI¢ SURVEY J ' ~J ORIGINAL TOWN OF' E]OYNTON EXHIBIT 'B' -,, I OC~ EXHIBIT 'B' II ! (~o' [ · ] '.~ :b ~l' ~,~ EXHIBIT 'B' - ~ ~" ~ ~EARCHESAT~TON B~CH ~a S~ ~ DROTOS EXHIBIT 'B' THE ARCHES AT BOYNTON WATER AND SEWER EXHIBIT 'B' EXHIBIT 'B' EXHIBIT 'B' EXHIBIT 'B' EXHIBIT 'B' The ~ches 0 BoSton Beach Boston Beach, FL Boynton Ventures 1, ~C EXHIBIT 'B' " EXHIBIT 'B' -' ~.~ ~ ~ EXHIBIT 'B' EXHIBIT 'B' EXHIBIT 'B' " EXHIBIT 'B' EXHIBIT 'B' EXHIBIT "C" Conditions o£ Approval Project name: The Arches File number: NWSP 03-002 Reference: 2~a review plans identified as a New Site Plan with an April 22, 2003 Planning & Zoning Division date stamp marking. DEPARTMENTS INCLUDE REJECT PUBLIC WORKS- General Comments: 1. Prior to permit application contact the Public Works Department (561-742- X 6200) regarding the storage and handling of refuse. The dumpster will be supplied by Public Works. PUBLIC WORKS- Traffic Comments: 2. Provide "2 Hr Parking - 8:30 A.M. to 5:30 P.M." signs along Ocean Avenue, X SE 1st Avenue, SE 2nd Avenue, and SE 4th Street, at approximate 100 feet spacing. 3. Add "No Parking" signs along Federal Highway. X UTILITIES Comments: 4. All utility easements shall be shown on the site plan, landscape plan, and X water and sewer plans. In general, palm trees will be the only tree species allowed within utility easements. Canopy trees may be planted outside the easement to ensure that the roots and branches will not impact those utilities within the easement in the foreseeable future. According to Chapter 7.5, Article I, Section 18.1, the public utilities has the authority to remove any trees that interfere with utility services, either in utility easements or public fights-of-way. 5. Fire flow calculations will be required demonstrating the City Code X requirement of 1,500 g.p.m, as stated in the LDR, Chapter 6, Article IV, Section 16, or the requirement imposed by insurance underwriters, whichever is ~eater (see CODE, Section 26-16(b)). 6. The CODE, Section 26-34(E) requires that a capacity reservation fee be paid X for this project either upon the request for the Department's signature on the Health Department application forms or within 30 days of site plan approval, whichever occurs first. This fee will be determined based upon final meter size, or expected demand. Conditions of Approval 2 DEPARTMENTS INCLUDE REJECT 7. The LDR, Chapter 3, Article IV, Section 3.P requires a statement be included X that (all other) utilities are available and will be provided by the appropriate agencies. This statement is lacking on the submitted plans. FIRE Comments: 8. Design documents shall demonstrate compliance with LDR Chapter 6, X Section 16, which provides requirements for hydrants. In addition to domestic requirements at a residual pressure of not less than 20 psi, a fire flow of at least 1500 gpm is required. 9. Design documents where underground water mains and hydrants are to be X provided, must demonstrate that they will be installed, completed, and in service prior to construction work per the Florida Fire Prevention Code, (2000) Section 29-2.3.2. 10. High-rise buildings shall be protected throughout by a Class I standpipe X system in accordance with Section 9.7. Florida Fire Prevention Code, (2000) Section 11.8.2.2. 11. Class 1, Type 60, standby power in accordance with NFPA 70, National X Electrical Code, and NFPA 110, Standard for Emergency and Standby Power Systems, shall be provided. Florida Fire Prevention Code, (2000) Section 11.8.4..2. POLICE Comments: None X ENGINEERING DIVISION Comments: 12. It may be necessary to replace or relocate large canopy trees adjacent to light X fixtures to eliminate future shadowing on the parking surface (LDR, Chapter 23, Article II, Section A. 1.b). 13. A new SFWMD permit or a modification to the existing permit will be X required for the proposed tie-in to the storm sewer system in SE 1 st Ave 14. Stormwater connection fees (Fee-In-Lieu-of Capital Improvements) will be X calculated and assessed after the SFWMD permit and stormwater connection issues are reconciled. 15. Provide an engineer's certification on the Drainage Plan as specified in LDR, X Chapter 4, Section 7.F.2. DEPARTMENTS INCLUDE R_EJECT 16. Full drainage plans in accordance with the LDR, Chapter 6, Article IV, X Section 5 will be required at the time of permitting. Additional comments and corrections to this plan may be generated at that time. BUILDING DIVISION Comments: 17. Identify within the site data the finish floor elevation (lowest floor elevation) X that is proposed for each building. Verify that the proposed elevation is in compliance with regulations of the code by adding specifications to the site data that address the following issues [Section 3107.1.2, Chapter 31 of the 2001 Florida Building Code]: a) The design professional-of-record for the project shall add the following text to the site data. "The proposed finish floor elevation NGVD is above the highest 100-year base flood elevation applicable to the building site, as determined by the South Florida Water Management District's surface water management construction development regulations." b) From the FIRM map, identify in the site data the title of the flood zone that the building is located within. Where applicable, specify the base flood elevation. If there is no base flood elevation, indicate that on the plans. c) Identify the floor elevation that the design professional has established for the building within the footprint of the building that is shown on the drawings titled site plan, floor plan and paving/ drainage (civil plans). 18. On the drawing titled site plan, identify and label the symbol that represents X the property line. 19. At time of permit review, provide a completed and executed City of Boynton X Beach Unity of Title form. The form shall describe all lots, parcels or tracts combined as one lot. A copy of the recorded deed with legal descriptions, of each property that is being unified, is required to be submitted to process the form. The property owner that is identified on each deed shall match. 20. At time of permit review, submit signed and sealed working drawings of the X proposed construction. 21. Add to each building that is depicted on the site plan drawing a labeled X symbol that identifies the location of the proposed handicap accessible units. Add to the drawing the calculations that were used to identify the minimum number of required units. Also, state the code section that is applicable to the computations. Show and label the same units on the applicable floor plan drawings. Compliance with regulations specified in the Fair Housing Act is required (Federal Fair Housing Act Design and Construction Requirements, 24 CFR 100.205). Conditions of Approval 4 DEPARTMENTS INCLUDE REJECT 22. Add to all plan view drawings of the site a labeled symbol that represents the X location and perimeter of the limits of construction proposed with the subject request. 23. At the time of permit review, submit details of reinforcement of walls for the X future installation of grab bars as required by the Federal Fair Housing Act 24 CFR 100.205, Section 3, Requirement #6. All bathrooms within the covered dwelling unit shall comply 24. All bathrooms in the covered dwelling unit shall comply with the provisions X of the Federal Fair Housing Act 24 CFR 100.205 (C)(3)(IV), Requirement #7 (2), Paragraph (A) or 03). Clear floor space shall be provided at fixtures to allow a person in a wheelchair or other mobility aid the use of the fixtures. Clear floor space shall be shown on the plans and designate which design option of requirement #7 (A or B) is being used. PARKS AND RECREATION Comments: None X FORESTER/ENVIRONMENTALIST Comments: None X PLANNING AND ZONING 25. Approval of this project is contingent upon the approval of the corresponding X request to rezone from CBD to MU-H (LUAR 03-003). 26. Approval of this project is contingent upon the approval of the corresponding X request to abandon the Southeast 1st Street alley (ABAN 03-002). If the abandonment is unsuccessful, modify site plan accordingly. 27. All proposed uses must be consistent w/th the MU-H zoning district identified X in Table 6F-1 in Chapter 2, Section 5.F.4 of the Land Development Regulations. 28. The proposed building areas must match between the traffic study and the site X plan. Prior to the issuance of the first building permit, the Palm Beach County Traffic Division must approve the traffic study. 29. A unity of title will be required prior to the issuance of a building permit. X 30. The drainage statement is required prior to the issuance of a building permit X (Chapter 4, Section 7.F.2.). 31. The average area of all residential units must not be below 1000 square feet X (Chapter 2, Section 6.F.5). On the site plan (sheet 3 of 6), indicate the average size of all the units to ensure compliance with the Land Development DEPARTMENTS INCLUDE REJECT Regulations. 32. On the site plan (sheet 3 of 6 prepared by Shah Drotos), correct the note for X Building "E" to indicate that the parking garage will be nine (9) stories tall (ground floor through 8~ floor will be for parking, the 9m floor will be for the recreation area). 33. The site plan (sheet 3 of 6 prepared by Shah Drotos) indicates that all of X Building "D" will be eight (8)-stories tall. However, the elevations and floor plans show the eastern portion of Building "D" will be only four (4)-stories tall. Revise the site plan (sheet 3 of 6) so that it accurately corresponds to the floor plans and elevations. 34. On the site plan (sheet 3 of 6 prepared by Shah Drotos), correct the required X number of parking spaces from 749 spaces to 750 spaces. Also, correct the number of provided parking spaces: (718 spaces in garage plus 35 surface parking spaces equals 753 parking spaces). 35. On the site plan (sheet 3 of 6 prepared by Shah Drotos), eliminate the X handicap parking spaces shown within the valet area on the north side of Southeast 1st Avenue. No parking may occur in this valet area. 36. Correct the number of provided parking spaces in the "garage summary" on X the First Floor Plan (prepared by Looney Ricks Kiss). Ensure that the parking summary on the plans prepared by Looney Ricks Kiss is consistent with the site plan (sheet 3 of 6 prepared b7 Shah Drotos). 37. Show the 88t~ parking space on the "Eighth Floor Plan" of the parking garage X (prepared by Loone7 Ricks Kiss). 38. On the west elevation of the parking garage (prepared by Looney Ricks Kiss), X indicate by note that the 9th floor will be the "Pool Deck / Garage Roof". 39. On the site plan (sheet 3 of 6 prepared by Shah Drotos) tabular data, revise X the note that currently reads, "OFFSITE PARKING PROVIDED (NOT COUNTED IN REQUIRED SPACES) to read the following: OFF-SITE PARKING (NOT INCLUDED IN PROVIDED SPACES) 40. Place a note on the site plan (sheet 3 of 6 prepared by Shah Drotos), that X based on the parking methodology used, the total number of seats for all restaurants shall not exceed 50 seats. Any additional seats will affect the required number of parking spaces and may cause the project to fall below the development standard. 41. As presented, the project will be limited to 20,652 square feet of gross X leasable (net) retail area and 15,444 square feet of gross leasable (net) office area (Chapter 2, Section 11.H.d.(2)). Any increase in leasable area will affect the required number of parking spaces and may cause the project to fall below the development standard. 42. The number of dwelling units / unit tvpe mix should match between the floor X Conditions of Approval 6 DEPARTMENTS INCLUDE REJECT plans (prepared by Looney Ricks Kiss) and the site plan tabular data (sheet 3 of 6 prepared by Shah Drotos). 43. The removal / relocation of trees is subject to review and approval by the City X Forester / Environmentalist. 44. On the landscape plan, ensure that the landscape species and quantities match X between the landscape plan and graphic illustration. 45. Revise the Shared Parking Table on the "Site / Project Data" sheet prepared X by Looney Ricks Kiss. Based upon the proposed uses and their respective intensities, the Shared Parking Table should read as follows: Weekday Weekend Daytime Evening Daytime Evening Nighttime Office i78 8 8 4 4 ~ Retail ~78 78 104 73 6 i Lodging - ' i Restaurant 63 126 126 126 13 Entertainment - - - Residential 308 512 ~ 512 512 512 Total 527 724 I 750 715 535 The number of required parking spaces shown in the above Shared Parking Table may be subject to change due to unforeseen revisions made to the plans during the permitting process. Also, the Table is subject to change without Board or City Commission action if the project demands less required parking due to decreased intensities (i.e. reduced office area, reduced number of dwelling units). However, if the intensities further increase and cause the project to become deficient in parking, any request to pay a "fee in lieu" of (providing additional parking spaces) shall be subject to the Community Redevelopment Agency and City Commission review and approval. 46. The elevations must indicate the proposed paint manufacturer's name and X color code prior to the issuance of a building permit. Staff recommends consistency between the colored drawing and the elevations. 47. All project signage is subject to review and approval of the Community X Redevelopment Agency and City Commission. Staff recommends submitting a sign program. 48. Staff recommends that the applicant should coordinate with Palm Tran for an X upgraded bus-stop facility. Please contact Mr. Gerry Gawaldo, a planner with the Palm Tran Department's Development Review Committee at (561) 841- 4246. DEPARTMENTS INCLUDE REJECT ADDITIONAL COMMUNITY REDEVELOPMENT AGENCY BOARD' CONDITIONS Comments: 49. The applicant and staff will work together to ensure that the proposed X awnings and landscaping do not conflict with each. 50. Ensure that any awnings proposed in rights-of-way are properly X permitted and approved by appropriate agencies. 51. The planter boxes (west of proposed garage) shall contain Bougainvillea and X shall be imgated. 52. The method of refuse collection (handling and storage) shall be re-evaluated X to confirm sufficiency and effectiveness. 53. Prior to the issuance of a building permit, the elevations shall indicate the X proposed colors and remm to the CRA for a courtesy review. ADDITIONAL CITY COMMISSION CONDITIONS Comments: 54. To be determined, x~,lko~' S:kPlanning\SHARED\WP\PROJECTSXARCHES ~ BB\NWSP 03-002\COA.doc i / OPENINING , EXHIBIT "D" .. RECEPTACL.~ AND /~. ~ LIGHT]N(; CIRCUITS. 1TING DIMENSIONS 0RILLING HOLES R"~ -~ ~/'"-I ~/2"PVC Il I ~ /(SOUND SYSTEM) _ 15" DiA. m:::o ~,NCHOR PLA TE:~ '--- *B.C: 12 1/~" DIA. *CAST ALUMINUM NOTE: THIS ANCHOR PLATE ACCEPTS 28"X60" A BOLT CIRCLE FROM 11 3/~" BANNER L SINGLE BANNER ARM @ 1,3" DIA. (BY OTHERS) - LUMEC ~AS28 (~,) ~.:-~5o, POLE BASE - CAST ,,LU,~,~,U. BALL PLAN VIEW - COLOR: COLTX SCALE: NONE' -- SINGLE BREAK AWAY BANNER ARM - LUMEC #BADS28 (560 - CAST ALUMINUM BALL - COLOR: COLTX 4.' DIA. FLUTED POLE .125 WALL THICKNESS 6061-1'6 STRUCTURAL. GRADE ALUMINUM. 5 (POLE: WELDED FOR' SINGLE UNIT CONSTRUCTION) ACCESS DOORS ~TH 3 STAINLESS STEEL 4 ANCHOR BOLTS ALLEN HEAD SCREWS. .3/4' X 32" WITH HOOK (GALVANIZED) STAT]ON AND OFFSET PT. FINISHED SEE SHEETS C14, & C15 GRADE DR!V~N CURB 2'-( COPPERWELD VERT]CAL 7'-0" CROUND ROD. BASE TYPICAL 5/4." X I0'-0" FOR ~,LL COPPER CLAD GROUND ROD ~ ~ TO POLE -- ~ TYPE "SA" LIGHT POLE ]ETAIL ~ TYPE "SD' SCALE: NONE ,.36' LPI I OUTL , l'. PROF SOU~ POWF