Ed Carey DesignDEVELOPMENT ORDER OF THE CITY COMMISSION OF THE
CITY OF BOYNTON BEACH, FLORIDA
PROJECT NAME:
APPLICANT'S AGENT:
Ed Carey Design
Mr. Edward Carey
APPLICANT'S ADDRESS: 2600 High Ridge Road Boynton Beach, FL 33426
DATE OF HEARING RATIFICATION BEFORE CITY COMMISSION: July 15, 2003
TYPE OF RELIEF SOUGHT: Request major site plan modification for the construction of a 1,940
square foot showroom addition to an existing 5,605 square foot
manufacturing business on a 1.77-acre lot in the PID zoning district.
LOCATION OF PROPERTY: 2600 High Ridge Road
DRAWING(S): SEE EXHIBIT "B" ATTACHED HERETO.
X THIS MATTER came before the City Commission of the City of Boynton Beach, Florida
appearing on the Consent Agenda on the date above. The City Commission hereby adopts the
findings and recommendation of the Planning and Development Board, which Board found as follows:
OR
THIS MATTER came on to be heard before the City Commission of the City of Boynton
Beach, Florida on the date of hearing stated above. The City Commission having considered the
relief sought by the applicant and heard testimony from the applicant, members of city administrative
staff and the public finds as follows:
Application for the relief sought was made by the Applicant in a manner consistent with
the requirements of the City's Land Development Regulations.
The Applicant
~" HAS
HAS NOT
established by substantial competent evidence a basis for the relief requested.
The conditions for development requested by the Applicant, administrative staff, or
suggested by the public and supported by substantial competent evidence are as set
forth on Exhibit "C" with notation "Included".
The Applicant's application for relief is hereby
K' GRANTED subject to the conditions referenced in paragraph 3 hereof.
DENIED
5. This Order shall take effect immediately upon issuance by the City Clerk.
All further development on the
and conditions of this order.
be made in accordance with the terms
7. Other
DATED: .~ "7-- I~ -O.~
S:\Planning\Sl-C~RED\WP\PROJECTS\Quantum Park Ed Carey ~)\MSPM 03-002 Bldg Addition\DO2.doc
Location Map
ED CAREY DESIGN
EXHIBIT "A"
NIC
R1AAA
IJJ
: ,'~ ~ 00
i,B.
i
Addition to:
Ed Carey
Design
~(3vnton Beach. Florida
EXHIBIT "B"
Addition to:
Ed Carey
· Design
Boynton Beach, Florida
Addition to:
Ed Carey
Design
Boynton Beach, Florida
Addition to:
Ed Carey'
-- ''l il i~ I r- r"~*- ' I : i-I [ ~' FII ~ .ri
I mi! ,",!~hi:; tiJfhlx Jtd, ,id I [ jill :
1 .',q;f- ii:il Jill;ii il,ii Ili
J JJl · r ! I , !
, ,,,f~ lr'.t -h ~, .dh .1 ~ !
~ 111Il rtJ~! ! 'il' .11. IlI j
i.
Addition to:
Ed Carey
I
'Desian
EXHIBIT "B"
Addition to:
Ed C.arey
EXHIBIT "C"
Conditions of Approval
Project name: Ed Carey Design
File number: MSPM 03-002
Reference: 3ndreview plans identified as a Major Site Plan Modification with a June 10, 2003 Planning and
Zoning Department date stamp marking.
DEPARTMENTS INCLUDE REJECT
PUBLIC WORKS - General
Comments: None X
PUBLIC WORKS - Traffic
Comments: None X
UTILITIES
Comments: None X
ENGINEERING DIVISION
Comments:
1. At the time of permitting, show the zoning and land use on the site X
characteristics map (Survey and Site Plan / Chapter 4, Section 7.A.).
2. Full drainage plans in accordance with the LDR, Chapter 6, Article IV, X
Section 5 will be required at the time of permitting.
3. Provide details for the proposed detention/retention areas and new riprap X
endwall.
FIRE
Comments:
4. In addition to domestic requirements at a residual pressure of not less than 20 X
psi, a fire flow of at least 1500 gpm is required.
POLICE
Comments: None X
BUILDING DIVISION
Comments:
COA
06/19/03
2
DEPARTMENTS INCLUDE REJECT
5. Buildings, structures and parts thereof shall be designed to withstand the X
minimum wind loads of 140 mph. Wind forces on every building or structure
shall be determined by the provisions of Chapter 6 of ASCE 7, and the
provisions of Section 1606 (Wind Loads) of the 2001 edition of the Florida
Building Code. Calculations that are signed and sealed by a design
professional registered in the state of Florida shall be submitted for review at
the time of permit application.
6. Identify within the site data the finish floor elevation (lowest floor elevation) X
that is proposed for the/each building. Verify that the proposed elevation is in
compliance with regulations of the code by adding specifications to the site
data that address the following issues [Section 3107.1.2, Chapter 31 of the
2001 Florida Building Code]:
a) From the FIRM map, identify in the site data the title of the flood zone
that the building is located within. Where applicable, specify the base
flood elevation. If there is no base flood elevation, indicate that on the
plans.
b) Identify the floor elevation that the design professional has established
for the building within the footprint of the building that is shown on
the drawings titled site plan, floor plan and paving/ drainage (civil
plans).
7. At time of permit review, submit signed and sealed working drawings of the X
proposed construction.
8. Accessible ramps shall comply with the 2001 Florida Building Code 11-4.8 X
through 11-4.8.8.
9. The second floor area shall comply with the requirements for vertical X
accessibility or meet the exceptions noted in the 2001 Florida Building Code
Section 11-4.1.2.
10. The new toilet room shall comply with the 2001 Florida Building Code X
Section 11-4.1.3(11), 11-4.2.3 and Figure 28.
11. Indicate the use of the second floor area and the minimum design load per the X
2001 Florida Building Code Section 1601.2 and Table 1604.1.
PARKS AND RECREATION
Comments: None X
FORESTER/ENVIRONMENTALIST
COA
06/19/03
DEPARTMENTS INCLUDE REJECT
Comments:
12. The landscape design does not include the City signature trees at the project X
ingress/egress location (Chapter. 7.5, Article II Sec. 5.C.3, N.
PLANNING AND ZONING
Comments:
13. At the time of permitting, the drainage plan shall be reviewed and approved X
by the Engineering Division (Chapter 4, Section 7.F.).
14. Prior to the issuance of a building permit, the elevation pages (sheet A-2 and X
sheet A-3) must indicate the proposed dimensions (including building height
and the overall height.
15. All elevations must indicate the proposed colors, including the paint X
manufacturer's name and color code (Chapter 4, Section 7.D.).
16. The existing building area (5,606 square feet) on the tabular data on sheet A- X
1 does not match the existing building area (5,605 square feet) on the tabular
data on sheet A-lA. This discrepancy between the two must be corrected
prior to the issuance of a building permit.
17. Staff recommends that the faqade enhancements proposed within Phase II X
begin no later than two (2) years (24 months) after the completion (certificate
of occupancy) of Phase I.
18. Applicant will be required to obtain a wholesale occupational license. X
ADDITIONAL PLANNING & DEVELOPMENT BOARD COMEMENTS:
Comments:
19. None X
ADDITIONAL CITY COMMISSION COMMENTS:
Comments:
20. To be determined. ~ ~
ELJ
S:\Planning\Shared\Wp\Projects\Ed Carey Design\MSPM 03-002 Bldg Addition\COA.doc