The Paving Lady DEVELOPMENT ORDER OF THE CITY COMMISSION OF THE
CITY OF BOYNTON BEACH, FLORIDA
PROJECT NAME: The Paving Lady
APPLICANT'S AGENT: Thomas Potter
APPLICANT'S ADDRESS: 1820 Tom-A-Toe Road Boynton Beach, FL 33426
DATE OF HEARING RATIFICATION BEFORE CITY COMMISSION: August 19, 2003
0~
TYPE OF RELIEF SOUGHT: Site Plan Approval for a 4,175 square foot office/warehouse in an
M-1 zoning district.
LOCATION OF PROPERTY: 1000 W. Industrial Avenue
DRAWING(S): SEE EXHIBIT "B" ATTACHED HERETO.
X THIS MATTER came before the City Commission of the City of Boynton Beach, Florida
appearing on the Consent Agenda on the date above. The City Commission hereby adopts the
findings and recommendation of the Planning and Development Board, which Board found as follows:
OR
THIS MATTER came on to be heard before the City Commission of the City of Boynton
Beach, Florida on the date of hearing stated above. The City Commission having considered the
relief sought by the applicant and heard testimony from the applicant, members of city administrative
staff and the public finds as follows:
Application for the relief sought was made by the Applicant in a manner consistent with
the requirements of the City's Land Development Regulations.
The Applicant
~. HAS
HAS NOT
established by substantial competent evidence a basis for the relief requested.
The conditions for development requested by the Applicant, administrative staff, or
suggested by the public and supported by substantial competent evidence are as set
forth on Exhibit "C" with notation "Included".
The APl~li.cant's application for relief is hereby
~( GRANTED subject to the conditions referenced in paragraph 3 hereof.
DENIED
5. This Order shall take effect immediately upon issuance by the City Clerk.
All further development on the property shall be made in accordance with the terms
and conditions of this order.
Other ~,o'f" ~'o4~
DATED:
S:\Planning\E
Clerk
Location Map
PAVING LADY NWSP 03-008
EXHIBIT "A"
I
Nw 10TH
i ;
PU
N
EXHIBIT "B'i
LAUREL HILLS -- THIRD ADDITION
(PLAT BOOK 2.3, PAGE 126) RESIDENTIAL
SEABOARD COASTLINE
EXHIBIT "B"
.t
PAVING LADY
90YNI'ON B~ACH. FLOR3DA
EXHIBIT "B"
!i
'h
L.
R£NOVA)'ION$ FOR:
PAVING LADY
BOYNTON BEACH, FLORIIDA
Jamoe~ ~ P.~..
VV I:.. b I I1",1 L2 U~ I I'~IAL
'A~'P~AL.T PAV[M£N"F
AVEI ~
]NCRETE PARKING
~ -H
/
m
RENOVATIONS FOR:
PAVING LADY
BOYN'TON O~CH. FLORIDA
I!
l
EXHIBIT "C"
Conditions of Approval
Project name: The Paving Lady
File number: NWSP 03-008
Reference: 2~d review plans identified as a New Site Plan with a June 17, 2003 Planning & Zoning Department
date stamp marking.
DEPARTMENTS INCLUDE REJECT
PUBLIC WORKS- General
Comments: None X
PUBLIC WORKS- Traffic
Comments: None X
UTILITIES
Comments:
1. Fire flow calculations will be required demonstrating the City Code X
requirement of 1,500 g.p.m, as stated in the LDR, Chapter 6, Article IV,
Section 16, or the requirement imposed by insurance underwriters,
whichever is ~eater (see CODE, Section 26-16(b)).
Comments: None X
POLICE
Comments: None X
ENGINEERING DIVISION
Comments:
2. Please note that changes or revisions to these plans may generate additional X
comments. Acceptance of these plans during the TRC process does not
ensure that additional comments may not be generated by the Commission
and at permit review.
3. Provide written and graphic scales on all sheets. X
4. Indicate to what standard the project is to be constructed; if the FDOT X
Standard Specifications for Road & Bridge Construction and Standard
Index are to be used - the 2000 Specifications are recommended since they
contain both English and Metric units.
5. Show proposed site lighting on the landscape plans (LDR, Chapter 4, X
Section 7.B.4.) The lighting design shall provide a minimum average light
level of one foot-candle. On the lighting plan, specify that the light poles
shall withstand a 140 MPH wind load (LDR, Chapter 23, Article Il, Section
A. 1 .a and Florida Building Code). Provide a note that the fixtures shall be
Conditions of Approval
2
DEPARTMENTS INCLUDE REJECT
operated by photoelectrical control and are to remain on until 2:00 a.m.
(LDR, Chapter 23, Article II, Section A. 1 .a.) Include pole wind loading,
and pole details in conformance with the LDR, Chapter 6, Article W,
Section 11, Chapter 23, Article I, Section 5.B.7 and Chapter 23, Article II,
Section A on the Lighting Plan. Glare which is readily perceptible at any
point at or beyond the property on which the use is located is prohibited
(LDR, Chapter 2, Section 4.N.7). Lighting shall be directed away from any
residential uses (LDR, Chapter 2, Section 4.N.7). Lighting shall not be used
as a form of advertising in a manner that draws more attention to the
building or grounds at night than in the day (LDR, Chapter 9, Section
10.F.5). If possible please provide photometrics as part of your TRC plan
submittals.
6. Show sight triangles on the landscape plans (LDR, Chapter 7.5, Article II, X
Section 5.H).
7. Full drainage plans in accordance with the LDR, Chapter 6, Article IV, X
Section 5 will be required at the time of permitting.
8. A complete review of details as shown on C-2, C-3 and C-5 will not be X
reviewed for construction acceptability at this time. All engineering
construction details shall be in accordance with the applicable City of
Boynton Beach Standard Drawings and will be reviewed for constmctability
at the time of construction permit application.
BUILDING DMSION
Comments:
9. Indicate within the site data the occupancy type of each building as defined X
in Chapter 3 of the 2001 Florida Building Code.
10. Buildings, structures and parts thereof shall be designed to withstand the X
minimum wind loads of 140 mph. Wind forces on every building or
structure shall be determined by the provisions of Chapter 6 of ASCE 7, and
the provisions of Section 1606 (Wind Loads) of the 2001 edition of the
Florida Building Code. Calculations that are signed and sealed by a design
professional registered in the state of Florida shall be submitted for review
at the time of permit application.
11. At time of permit review, submit signed and sealed working drawings of the X
proposed construction.
12. A water-use permit for the irrigation system is required from the South X
Florida Water Management District. A copy of the permit shall be submitted
at the time of permit application. Florida Statute 373.216.
13. Clearly show the door on the toilet room marked "ADA". The swing of the X
door on both accessible toilet rooms shall comply with the 2001 Florida
Building Code, Section 11-4.22.2.
PARKS AND RECREATION
Comments: None X
DEPARTMENTS INCLUDE REJECT
FORESTER/ENVIRONMENTALIST
Comments:
14. All trees on the Plant List must be listed in the specifications as a minimum X
of 12 feet-14feet height, 3-inch caliper at DBH (4.5 feet offthe ground), and
Florida # 1 (Florida Grades and Standards manual) [Environmental
Regulations, Chapter 7.5, Article II Sec. 5.C. 2.]
15. Trees listed in the Palm Beach County "invasive plant species" and" X
invasive non-native plant" listing should not be included in the landscape
design. [Environmental Regulations, Chapter 7.5, Article I Sec. 19A.5.]
16. The applicant should indicate a minimum of 50% native species calculation X
on all landscape materials throughout the site. [Environmental Regulations,
Chapter 7.5, Article II Sec. 5.C. 3.N.]
17. The West Industrial Avenue road right-of-way must receive sod and X
irrigation coverage. [Environmental Regulations, Chapter 7.5, Article II Sec.
5.C. 2.1
PLANNING AND ZONING
Comments:
18. An environmental review permit is required. Apply for an environmental X
review permit.
19. The landscape plan should show the location of all outdoor freestanding X
lighting structures.
20. The freestanding monument sign is proposed to be located within the 50- X
foot drainage easement. Provide an express written consent of all legal
entities occupying said easement at time of permitting.
ADDITIONAL COMMUNITY REDEVELOPMENT AGENCY BOARD
CONDITIONS
Comments:
21. Provide a consistent 6-inch banding around all windows on the proposed X
buildings.
22. On the plans correct the notations regarding the future building to X
"proposed buildings".
23. The gates on the dumpster enclosure be replaced with wood gates with steel X
frames.
ADDITIONAL CITY COMMISSION CONDITIONS
Comments:
24. To be determined. ~3"/~ ~ ~