Dr Ka Hock Go DaycareDEVELOPMEr ORDER OF THE CITY COMMISS'
CITY OF BOYNTON BEACH, FLORIDA
PROJECT NAME: Dr. Ka Hock Go Daycare
APPLICANT'S AGENT: David Beasley
APPLICANT'S ADDRESS: 3570 Kitely Avenue, Boynton Beach, FL 33436
~1 OF THE
Development
P&Z
Building.
Engineering
0cc. License
Deputy City Clerk
DATE OF HEARING RATIFICATION BEFORE CITY COMMISSION: February 1, 2005
TYPE OF RELIEF SOUGHT: Request for Conditional Use/New Site Plan approval for the conversion
of 7,098 square feet of an existing 13,170 square foot professional office
building to daycare use
LOCATION OF PROPERTY: 3452 West Boynton Beach Boulevard / SE corner of Knuth Road and
Boynton Beach Boulevard
DRAWING(S): SEE EXHIBIT "B" ATTACHED HERETO.
THIS MATTER came before the City Commission of the City of Boynton Beach, Florida
appearing on the Consent Agenda on the date above. The City Commission hereby adopts the
findings and recommendation of the Planning and Development Board, which Board found as follows:
OR
X THIS MATTER came on to be heard before the City Commission of the City of Boynton
Beach, Florida on the date of hearing stated above. The City Commission having considered the
relief sought by the applicant and heard testimony from the applicant, members of city administrative
staff and the public finds as follows:
Application for the relief sought was made by the Applicant in a manner consistent with
the requirements of the City's Land Development Regulations.
The Applicant
~/HAS
HAS NOT
established by substantial competent evidence a basis for the relief requested.
The conditions for development requested by the Applicant, administrative staff, or
suggested by the public and supported by substantial competent evidence are as set
forth on Exhibit "C" with notation "Included".
The Applicant's application for relief is hereby
,/GRANTED subject to the conditions referenced in paragraph 3 hereof.
DENIED
5. This Order shall take effect immediately upon issuance by the City Clerk.
7. Other
DATED: ~.~ - ~-(.J5
S:\Planning\SHARED\WP\PROJECTS\Dr.
All further development on the property shall be made in accordance with the terms
and conditions of this order.
IS 05-001\DO forP&D.doc
~l],l~
~,1~,~
~'1~
~13,~
'.
EXHIBIT B
EXHIBIT "C"
Conditions of Approval
Project name: Dr. Go's Daycare
File number: COUS 05-002
Reference: 2n~ review plans identified as a Conditional Use with a December 14, 2004 Planning & Zoning date
stamp marking.
DEPARTMENTS 1NCLUDE REJECT
PUBLIC WORKS- General
Comments: None X
PUBLIC WORKS- Traffic
Comments:
1. Provide a traffic analysis and notice of concurrency (Traffic X
Performance Standards Review) from Palm Beach County Traffic
Engineering.
2. On the Site and Civil plans, show and idc~ntify all necessary traffic control X
devices such as stop bars, stop signs, double yellow lane separators striping,
directional arrows and "Do Not Enter" signage, etc. Delineate and stripe the
"Loading Area" (where applicable - LDR, Chapter 2, Section 11 .J); include
a pavement message in yellow indicating "No Parking - Loading Zone".
See City Standard Drawings "K" Series for striping details. Indicate by note
re-striping.
3. Widen egress driveway to a minimum width of 15 feet and round off the X
Type "D" curb to eliminate the notch on the southeast side of the driveway,
UTILITIES
Comments: None X
FIRE
Comments: None X
POLICE
Comments: None X
ENGINEERING DIVISION
Comments:
4. Add a general note to the Site Plan that all plans submitted for specific X
permits shall meet the City's Code requirements at time of application.
These l~ermits include, but are not limited to, the following: pavin~,
Conditions of Approval
2
DEPARTMENTS INCLUDE REJECT
drainage, curbing, site lighting, landscaping and irrigation. Permits
required from other permitting agencies such as Florida Department of
Transportation (FDOT), South Florida Water Management District
(SFWMD), Lake Worth Drainage District (LWDD), Florida Department
of Environmental Protection (FDEP), Palm Beach County Health
Department (PBCHD), Palm Beach County Engineering Department
(PBCED), Palm Beach County Department of Environmental Resource
Management (PBCDERM) and any others, shall be included with the
permit request.
5. All comments requir/ng changes and/or corrections to the plans shall be X
reflected on all appropriate sheets.
6. Please note that changes or revisions to these plans may generate X
additional comments. Acceptance of these plans during the TRC
process does not ensure that additional comments may not be generated
by the Commission and at pm'mit review.
7. Show site lighting on the Site plan (LDR, Chapter 4, Section 7.B.4.) X
The lighting design shall provide a minimum average light level of one
foot-candle.
8. Ail engineering construction details shall be in accordance with the X
applicable City of Boynton Beach Standard Drawings and the
"Engineering Design Handbook and Construction Standards" and
will be reviewed at the time of construction permit application.
BUILDING DIVISION
Comments:
9. Please note that changes or revisions to these plans may generate additional X
comments. Acceptance of these plans during the TRC process does not
ensure that additional comments may not be generated by the commission
and at permit review.
10. Indicate within the site data the type of construction of the building as X
defined in 2001 FBC, Chapter 6.
1 I. At time of permit review, submit signed and sealed working drawings of the X
proposed construction.
12. Add a labeled symbol to the site plan drawing that identifies the location of X
the handicap accessible parking spaces. The quantity of the spaces shall be
consistent with the regulations specified in the 2001 FBC. The accessible
parking spaces that serve a use shall be located on the shortest safety
accessible route of travel from adjacent parking to an accessible entrance.
The 2001 FBC states that buildings with multil~le accessible entrances shall
DEPARTMENTS 1NCLUDE REJECT
have accessible parking spaces dispersed and located closest to the
accessible entrance. 2001 FBC, Sections 11-4.1.2(5), 4.3, and 4.6.
13. Add a labeled symbol to the site plan drawing that represents and delineate~ X
the path of travel for the accessible route that is required between the
accessible parking spaces and the accessible entrance doors to the building.
The installed symbol, required along the path, shall start at the accessible
parking spaces and terminate at the accessible entrance doors to the
building. The symbol shall represent the location of the path of travel, not
the location of the detectable warning or other pavement markings. The
location of the accessible path shall not compel the user to travel in a
drive/lane area that is located behind parked vehicles. Identify on the plan
the width of the accessible route. (Note: The minimum clear width of an
accessible route shall be 36 inches, except at curb ramps that are part of a
required means of egress shall not be less than 44 inches). Add text to the
drawing that would indicate that the symbol represents the accessible route
and the route is designed in compliance with 2001 FBC, Section 11-4.3
(Accessible Route) and 11-4.6 (Parking and Passenger Loading Zones).
Please note that at time of permit review, the applicant shall provide detailed
documentation on the plans that will verify that the accessible route is in
compliance with the regulations specified in the 2001 FBC. This
documentation shall include, but not be limited to, providing finish grade
elevations along the path of travel.
14. Add to the drawing the calculations that were used to identify the minimum X
number of required handicap accessible parking spaces. Also, state the
code section that is applicable to the computations.
15. Indicate on the floor plan drawing within the footprint of the building the X
primary use of the building. If the building is an expansion of an existing
building, indicate with the footprint of the new and existing building the
primary use of the building.
16. Pursuant to approval by the City CornnUssion and all other outside agencies, X
the plans for this project must be submitted to the Building Division for
review at the time of permit application submittal. The plans must
incorporate all the conditions of approval as listed in the development order
and approved by the City Commission.
17. The number of handicap accessible parking spaces shall comply with the X
2001 FBC, section 11-4.1.2(5)(a).
18. Sheet A-2 - The doors to the accessible toilet rooms shall not swing into the X
clear floor space of fixtures per the 2001 FBC, Section 11-4.22.2(1).
19. Indicate on the plan the number of occupants based on 2001 FBC, Table X
1003.
20. A smoke detection system is required per the 2001 FBC, Section X
418.7.2.
PARKS AND RECREATION
Conditions of Approval
DEPARTMENTS INCLUDE REJECT
Comments: None X
FORESTER/ENVIRONMENTALIST
Comments:
21. The comment under "General Notes" pertaining to the existing site X
landscaping is no~t all existing. There are many site trees and additional
landscaping that have been damaged or destroyed by the two past hurricane
events. A new landscape plan should be submitted in conjunction with the
site plan.
PLANNING AND ZONING
Comments:
22. Number each parking space on the site plan.
23. Provide an affidavit regarding the applicant's responsibility for public X
noticing, consistent with Ordinance No. 04-007.
24. The facilities shall comply with Health Department and all other Regulatory X
Agency requirements.
ADDITIONAL PLANNING & DEVELOPMENT BOARD CONDITIONS
Comments:
1. None X
ADDITIONAL CITY COMMISSION CONDITIONS
Comments:
1. To be determined.