Verizon Stealth Cellular TowerDEVELOPMENT ORDER OF THE CITY COMMISSION OF THE
CITY OF BOYNTON BEACH, FLORIDA
PROJECT NAME:
APPLICANT'S AGENT:
APPLICANT'S ADDRESS:
Verizon Stealth Cellular Tower (Boynton Space Plus Storage)
Jason Laskey SBA Network Services
5900 Broken Sound Parkway NW Boca Raton, FL 33487
DATE OF HEARING RATIFICATION BEFORE CITY COMMISSION: March 1,2005
TYPE OF RELIEF SOUGHT: Request for Conditional Use/New Site Plan approval for a 135 foot high
cellular tower in an M-1 zoning district.
LOCATION OF PROPERTY: 2951 SW 14th Place
DRAWING(S): SEE EXHIBIT "B" ATTACHED HERETO.
X THIS MATTER came before the City Commission of the City of Boynton Beach, Florida
appearing on the Consent Agenda on the date above. The City Commission hereby adopts the
findings and recommendation of the Planning and Development Board, which Board found as follows:
OR
THIS MATTER came on to be heard before the City Commission of the City of Boynton
Beach, Florida on the date of hearing stated above. The City Commission having considered the
relief sought by the applicant and heard testimony from the applicant, members of city administrative
staff and the public finds as follows:
Application for the relief sought was made by the Applicant in a manner consistent with
the requirements of the City's Land Development Regulations.
The App~HAS
HAS NOT
established by substantial competent evidence a basis for the relief requested.
The conditions for development requested by the Applicant, administrative staff, or
suggested by the public and supported by substantial competent evidence are as set
forth on Exhibit "C" with notation "Included".
The Applica~l~t's application for relief is hereby
~ GRANTED subject to the conditions referenced in paragraph 3 hereof.
DENIED
5. This Order shall take effect immediately upon issuance by the City Clerk.
All further development on the property shall be made in accordance with the terms
and conditions of this order.
7. Other
~lre --- ~;,ty Clerk
S:\Planning\SHARED\WP\PROJECTS~Veriz less Mega Mini 2951 SW 14th PI
msnssn g
Ii
]:DV-Id H.LB;-
~ S'c3=IklE)NO0
~XHI BIT A
1
1 in. = 166.2 feet
Mega Mini/Storage Plus outdoor storage
EXHIBIT B
AERIAL OF PARENT TRACT
EXHIBIT C
PROPOSED SITE PLAN
I;l!![il
Iill!;ll
Iiililil
EXHIBIT'C
~OPOSED SITE PLAN
EXHIBIT C
PROPOSED SITE PLAN.
.oo s.0w, iI::Xl-llldI I L} i(JWER DETAILS
~ 21 4750 I
SHAFT ."II
--" -I .... I ^TT^CHIdENlmJP/IdOUNTS, 'F;.o. BOX 8597 FORT W~II~T'H, TX 76124-0597
~ ] PLATFORIdS, HANDHOI. ES, PHONE: (800) 433-1816 FAX: (817) 255-8656
I IZrC.
I I W~GHTS PRIOR TO
&opROX~U~; mtn, I ~ 5~Oq I urnN~. ·
Page J 0 B 0 A T A
1 of 1 Job No, J0411220011
By TWL ~Design No.
MO4--og2g-A
Date 10/11/2004. 3:25:2,~ PM
Chk~d By ...~v,,,/ Rev. No. Rev:
Dote
'"Pole 13!5-FT MONOPOLE
Site SPACE PLUS STORAGE, ip68650, FL
Owner VERIZON WIRElESS
Ref. No.
Oesign I~E.[T 140 MPH 3-SECOND GUST SPEED PER FBC 2003 /AN
ACCORDING TO TIA//ElA-222-F 1996
NOTE: FLAG TO
BE OMITTED
135'-0'
135'-0'
125'-0'
I 15'-0'
98'-8"
~'~:,A~TH CEM..-3C-125-~0
112'LX12'~tX6'D)
26.625 ACROSS FLAIS
o.~9
lan = ~.~
~= ~.~
RNAL DESIGN - NOT FOR FABRICATION
LOAD CASES
CASE 11120 MPH wrrH NO ICE DESIGN
. OPERATIONAL
ICASE 2t50 MPH WITH NO lee WINDJ
WIND
LE SPECIFICATIONS -
I Pole Shape TyPpe? 18--SIDED POLYGON
Toper: 0.135714 IN/FT
Shaft Steel: ASTM A572 GRADE 65
Base PL Steel: ASTM A633 GR. E (60 KSI)
Anchor Bolts: 2 1/4.e x 7'-0 LONG
~18J ASTM A615 GRADE 75
PY I 3TCt, I 11:5~: 15 FT.LBS e -20'F
A NTI~ N N A LIST
No. Elev. Description
- 136.00 (1) ~ B~LL & 11~kCKING PULLEr ~ ~N
129.~ (1) m (12' X 18')
- - ~-12-02 (~12~)
120 MPH WIND 50 MPH WIND
Lateral Rotation Lateral Rotation
Elevation Deflection . (sway) Deflection . (sway)
(Inches) (degrees) (Inches) (degrees)
105' 62.2 5.0~.2 10.8 0.875
MIN - 47,70
DE~N= 53,00
I~X = 58.00
x6Jw~ 53.0~ (r~.~)
- 6.4,58 KIPS)
SHAFT SECTION OATA
Shaft Section Plate Lap Diameter Across Flats
.Long .fl1 Thickness Splice (inches)
Section (fset) , (in.) (in.} 0 Top 0 Bottom
1 10.00 O. 1875 26.625 27.982
2 50.08 0.2500 44.00
3 53.00 0.3125 53.00 27.110 33.907
32,807 40.000
40TE: DIMENSIONS SHOWN IX) NOT INCLUDE GALVANIZING TOLI~_._FS
· :1 X 48.750 SQUARE - 1.550 KIPS)
m m ~ ~c. m ua. ~'-o
MOMENT = 1639 ff-~ps
SHEAR = 20.5 kips
AXIAL = 19.0 kips
EST. SHAFT + BASE [ WT. -- 12.6 kips
EXHIBIT E
1 in. = 179.9 feet
Hester Center Tower Site (150 foot tower @ 453 foot radius)
EXHIBIT "F"
Conditions of Approval
Project name: Verizon Wireless Tower at Boynton Space Plus Storage
File number: COUS 05-003
Reference: 2nd Review plans identified as a Conditional Use Site Plan with a January 25, 2005 Planning &
Zoning date stamp marking.
DEPARTMENTS INCLUDE REJECT
PUBLIC WORKS- General
Comments:
1. Provide a dumpster enclosure per the LDR, Chapter 2, Section 11.J.2.b. X
2. Indicate by note that the site dumpster enclosure shall be constructed in X
accordance with City Standard Drawing G-4.
3. A minimum dumpster pad is required measuring 10 feet x 10 feet (inside X
dimension including gates). (LDR, Chapter 7.5, Article II, Section 5.J. and
Article III, section 9.A.9.a.)
4. The required gates for the dumpster shall contain long steel rods to drop into X
thc pavement in order to secure the gates in the open and closed positions.
Drilled holes (for concrete) or metal sleeves (for asphalt) shall be provided
for the locking rods.
5. Walls for thc enclosure shall be provided on three sides and are to be a X
minimum of 6 feet high and shall be CBS construction with a finish
matching that of the adjacent buildings(s). Accent shrubs shall be provided
along the screen wall(s) (LDR, Chapter 7.5, Article II, Section 5.J., and
Article III, Section 9.A.9.a, and Chapter 9, Section 10.C.3.)
6. Provide a minimum turning radius of 60 feet to approach the dumpster. X
Provide a minimum backing clearance of 60 feet. (measured from the front
edge of the dumpster pad.) (LDR, Chapter 2, Section 11.J.2.b.)
PUBLIC WORKS- Traffic
Comments: None X
UTILITIES
Comments: None X
FIRE
Comments: None X
POLICE
Comments: None X
Conditions of Approval
2
DEPARTMENTS INCLUDE REJECT
ENGINEERING DIVISION
Comments:
7. All comments requiring changes and~or corrections to the plans shall be X
reflected on all appropriate sheets.
8. Please note that changes or revisions to these plans may generate additional X
comments. Acceptance of these plans during the TRC process does not
ensure that additional comments may not be generated by the Commission
and at permit review.
9. Full drainage plans, including drainage calculations, in accordance with the X
LDR, Chapter 6, Article IV, Section 5 will be required at the time of
permitting.
10. Paving, Drainage and Site details will not be reviewed for construction X
acceptability at this time. All engineering construction details shall be in
accordance with the applicable City of Boynton Beach Standard Drawings
and the "Engineering Design Handbook and Construction Standards"
and will be reviewed at the time of construction permit application.
BUILDING DIVISION
Comments:
11. Plans for the LP tank and generator shall be submitted at the time of permit X
submittal for the tower.
12. Buildings, structures and parts thereof shall be designed to withstand the X
minimum wind loads of 140 mph. Wind forces on every building or
structure shall be determined by the provisions of ASCE 7, Chapter 6, and
the provisions of the 2001 FBC, Section 1606 (Wind Loads). Calculations
that are signed and sealed by a design professional registered in the State of
Florida shall be submitted for review at the time of permit application.
PARKS AND RECREATION
Comments: None X
FORESTER/ENVIRONMENTALIST
Comments:
Landscape Plan-Plant List Sheet L-3 of 4 X
12. All shade trees on the Plant List must be listed in the specifications as a
minimum of 12'-14' height, Y' diameter at DBH (4.5' off the ground), and
Florida #1 (Florida Grades and Standards manual) The height of the trees
may be larger than 12'-14' to meet the Y' diameter requirement.
[Environmental Regulations, Chapter 7.5, Article II Sec. 5.C. 2.]
13. The Tree Planting Detail should include a line indicating where the X
diameter at breast height (DBH) of the shade tree will be measured at time
DEPARTMENTS INCLUDE REJECT
of planting and inspection.
14. Cypress mulch cannot be used on the site and reference to this product X
should be removed from the notes.
15. There is no irrigation system design included with the site plans. The X
irrigation design should be micro-irrigation for water conservation.
[Environmental Regulations, Chapter 7.5, Article II Sec. 5A.]
16. Turf areas should be limited in size. Landscape (bedding plants) areas X
should be designed on separate zones with proper time duration for water
conservation. Environmental Regulations, Chapter 7.5, Article II Sec. 5.
C.2.]
17. All trees on the site should receive irrigation from a separate bubbler. X
[Environmental Regulations, Chapter 7.5, Article II Sec. 5. C.2.]
PLANNING AND ZONING
Comments:
18. Clarify through proper labeling of data for required parking to only regard X
storage use on parent tract.
19. Map document in application excludes dimension to nearest tower, possibly X
shown as a red dot and numbered 8650, or clarify accordingly. Locate
correctly search ring number 8650.
20. Provide amended site plan, at time of permit filing, showing compliance I X]
with all applicable comments/conditions.
21. Provide access easement agreement with request for permits. [ X I
22. Provide Radio Frequency data from project engineer to document void in I X I
coverage and therefore necessity for proposed tower.
23. Provide structural/engineering data to confirm design is capable of X
collocation and number of carriers and corresponding heights. Include this
information in certification letter from project engineer.
24. Existing fence on south side of proposed lease area and slats are in need X
repair. Straighten fence and replace slats behind lease area and behind and
around dumpster station (if to remain).
25. Relocation of dumpster(s) may require proper siting and screening in I XI
accordance with Land Development Regulations.
26. Existing perimeter hedge is in poor condition and provides limited X
screening contrary to approved plan and original intent. Indicate where
landscape material will be enhanced to provide required screening. Large
voids in the entire perimeter landscaping shall be improved as a condition of
approval, with new plantings.
27. Revise certification letter to affirm compliance with all requirements as X
stated in Sec. 3.C.2 of Chapter 10., including with height requirements as to
be measured from crown of nearest road (or provide survey documentation
verifying same).
Conditions of Approval
4
DEPARTMENTS INCLUDE REJECT
28. Specifically indicate paint/material color on elevation graphic; include any I XI
available material samples and/or swatches.
ADDITIONAL PLANNING & DEVELOPMENT BOARD CONDITIONS
Comments:
1. None X
ADDITIONAL CITY COMMISSION CONDITIONS
Comments:
1. To be determined.
S:\Planning\SHARED\WP~PROJECTSWerizon Wireless Mega Mini 2951 SW 14th Pl\COA.doc