Loading...
Verizon Stealth Cellular TowerDEVELOPMENT ORDER OF THE CITY COMMISSION OF THE CITY OF BOYNTON BEACH, FLORIDA PROJECT NAME: APPLICANT'S AGENT: APPLICANT'S ADDRESS: Verizon Stealth Cellular Tower (Boynton Space Plus Storage) Jason Laskey SBA Network Services 5900 Broken Sound Parkway NW Boca Raton, FL 33487 DATE OF HEARING RATIFICATION BEFORE CITY COMMISSION: March 1,2005 TYPE OF RELIEF SOUGHT: Request for Conditional Use/New Site Plan approval for a 135 foot high cellular tower in an M-1 zoning district. LOCATION OF PROPERTY: 2951 SW 14th Place DRAWING(S): SEE EXHIBIT "B" ATTACHED HERETO. X THIS MATTER came before the City Commission of the City of Boynton Beach, Florida appearing on the Consent Agenda on the date above. The City Commission hereby adopts the findings and recommendation of the Planning and Development Board, which Board found as follows: OR THIS MATTER came on to be heard before the City Commission of the City of Boynton Beach, Florida on the date of hearing stated above. The City Commission having considered the relief sought by the applicant and heard testimony from the applicant, members of city administrative staff and the public finds as follows: Application for the relief sought was made by the Applicant in a manner consistent with the requirements of the City's Land Development Regulations. The App~HAS HAS NOT established by substantial competent evidence a basis for the relief requested. The conditions for development requested by the Applicant, administrative staff, or suggested by the public and supported by substantial competent evidence are as set forth on Exhibit "C" with notation "Included". The Applica~l~t's application for relief is hereby ~ GRANTED subject to the conditions referenced in paragraph 3 hereof. DENIED 5. This Order shall take effect immediately upon issuance by the City Clerk. All further development on the property shall be made in accordance with the terms and conditions of this order. 7. Other ~lre --- ~;,ty Clerk S:\Planning\SHARED\WP\PROJECTS~Veriz less Mega Mini 2951 SW 14th PI msnssn g Ii ]:DV-Id H.LB;- ~ S'c3=IklE)NO0 ~XHI BIT A 1 1 in. = 166.2 feet Mega Mini/Storage Plus outdoor storage EXHIBIT B AERIAL OF PARENT TRACT EXHIBIT C PROPOSED SITE PLAN I;l!![il Iill!;ll Iiililil EXHIBIT'C ~OPOSED SITE PLAN EXHIBIT C PROPOSED SITE PLAN. .oo s.0w, iI::Xl-llldI I L} i(JWER DETAILS ~ 21 4750 I SHAFT ."II --" -I .... I ^TT^CHIdENlmJP/IdOUNTS, 'F;.o. BOX 8597 FORT W~II~T'H, TX 76124-0597 ~ ] PLATFORIdS, HANDHOI. ES, PHONE: (800) 433-1816 FAX: (817) 255-8656 I IZrC. I I W~GHTS PRIOR TO &opROX~U~; mtn, I ~ 5~Oq I urnN~. · Page J 0 B 0 A T A 1 of 1 Job No, J0411220011 By TWL ~Design No. MO4--og2g-A Date 10/11/2004. 3:25:2,~ PM Chk~d By ...~v,,,/ Rev. No. Rev: Dote '"Pole 13!5-FT MONOPOLE Site SPACE PLUS STORAGE, ip68650, FL Owner VERIZON WIRElESS Ref. No. Oesign I~E.[T 140 MPH 3-SECOND GUST SPEED PER FBC 2003 /AN ACCORDING TO TIA//ElA-222-F 1996 NOTE: FLAG TO BE OMITTED 135'-0' 135'-0' 125'-0' I 15'-0' 98'-8" ~'~:,A~TH CEM..-3C-125-~0 112'LX12'~tX6'D) 26.625 ACROSS FLAIS o.~9 lan = ~.~ ~= ~.~ RNAL DESIGN - NOT FOR FABRICATION LOAD CASES CASE 11120 MPH wrrH NO ICE DESIGN . OPERATIONAL ICASE 2t50 MPH WITH NO lee WINDJ WIND LE SPECIFICATIONS - I Pole Shape TyPpe? 18--SIDED POLYGON Toper: 0.135714 IN/FT Shaft Steel: ASTM A572 GRADE 65 Base PL Steel: ASTM A633 GR. E (60 KSI) Anchor Bolts: 2 1/4.e x 7'-0 LONG ~18J ASTM A615 GRADE 75 PY I 3TCt, I 11:5~: 15 FT.LBS e -20'F A NTI~ N N A LIST No. Elev. Description - 136.00 (1) ~ B~LL & 11~kCKING PULLEr ~ ~N 129.~ (1) m (12' X 18') - - ~-12-02 (~12~) 120 MPH WIND 50 MPH WIND Lateral Rotation Lateral Rotation Elevation Deflection . (sway) Deflection . (sway) (Inches) (degrees) (Inches) (degrees) 105' 62.2 5.0~.2 10.8 0.875 MIN - 47,70 DE~N= 53,00 I~X = 58.00 x6Jw~ 53.0~ (r~.~) - 6.4,58 KIPS) SHAFT SECTION OATA Shaft Section Plate Lap Diameter Across Flats .Long .fl1 Thickness Splice (inches) Section (fset) , (in.) (in.} 0 Top 0 Bottom 1 10.00 O. 1875 26.625 27.982 2 50.08 0.2500 44.00 3 53.00 0.3125 53.00 27.110 33.907 32,807 40.000 40TE: DIMENSIONS SHOWN IX) NOT INCLUDE GALVANIZING TOLI~_._FS · :1 X 48.750 SQUARE - 1.550 KIPS) m m ~ ~c. m ua. ~'-o MOMENT = 1639 ff-~ps SHEAR = 20.5 kips AXIAL = 19.0 kips EST. SHAFT + BASE [ WT. -- 12.6 kips EXHIBIT E 1 in. = 179.9 feet Hester Center Tower Site (150 foot tower @ 453 foot radius) EXHIBIT "F" Conditions of Approval Project name: Verizon Wireless Tower at Boynton Space Plus Storage File number: COUS 05-003 Reference: 2nd Review plans identified as a Conditional Use Site Plan with a January 25, 2005 Planning & Zoning date stamp marking. DEPARTMENTS INCLUDE REJECT PUBLIC WORKS- General Comments: 1. Provide a dumpster enclosure per the LDR, Chapter 2, Section 11.J.2.b. X 2. Indicate by note that the site dumpster enclosure shall be constructed in X accordance with City Standard Drawing G-4. 3. A minimum dumpster pad is required measuring 10 feet x 10 feet (inside X dimension including gates). (LDR, Chapter 7.5, Article II, Section 5.J. and Article III, section 9.A.9.a.) 4. The required gates for the dumpster shall contain long steel rods to drop into X thc pavement in order to secure the gates in the open and closed positions. Drilled holes (for concrete) or metal sleeves (for asphalt) shall be provided for the locking rods. 5. Walls for thc enclosure shall be provided on three sides and are to be a X minimum of 6 feet high and shall be CBS construction with a finish matching that of the adjacent buildings(s). Accent shrubs shall be provided along the screen wall(s) (LDR, Chapter 7.5, Article II, Section 5.J., and Article III, Section 9.A.9.a, and Chapter 9, Section 10.C.3.) 6. Provide a minimum turning radius of 60 feet to approach the dumpster. X Provide a minimum backing clearance of 60 feet. (measured from the front edge of the dumpster pad.) (LDR, Chapter 2, Section 11.J.2.b.) PUBLIC WORKS- Traffic Comments: None X UTILITIES Comments: None X FIRE Comments: None X POLICE Comments: None X Conditions of Approval 2 DEPARTMENTS INCLUDE REJECT ENGINEERING DIVISION Comments: 7. All comments requiring changes and~or corrections to the plans shall be X reflected on all appropriate sheets. 8. Please note that changes or revisions to these plans may generate additional X comments. Acceptance of these plans during the TRC process does not ensure that additional comments may not be generated by the Commission and at permit review. 9. Full drainage plans, including drainage calculations, in accordance with the X LDR, Chapter 6, Article IV, Section 5 will be required at the time of permitting. 10. Paving, Drainage and Site details will not be reviewed for construction X acceptability at this time. All engineering construction details shall be in accordance with the applicable City of Boynton Beach Standard Drawings and the "Engineering Design Handbook and Construction Standards" and will be reviewed at the time of construction permit application. BUILDING DIVISION Comments: 11. Plans for the LP tank and generator shall be submitted at the time of permit X submittal for the tower. 12. Buildings, structures and parts thereof shall be designed to withstand the X minimum wind loads of 140 mph. Wind forces on every building or structure shall be determined by the provisions of ASCE 7, Chapter 6, and the provisions of the 2001 FBC, Section 1606 (Wind Loads). Calculations that are signed and sealed by a design professional registered in the State of Florida shall be submitted for review at the time of permit application. PARKS AND RECREATION Comments: None X FORESTER/ENVIRONMENTALIST Comments: Landscape Plan-Plant List Sheet L-3 of 4 X 12. All shade trees on the Plant List must be listed in the specifications as a minimum of 12'-14' height, Y' diameter at DBH (4.5' off the ground), and Florida #1 (Florida Grades and Standards manual) The height of the trees may be larger than 12'-14' to meet the Y' diameter requirement. [Environmental Regulations, Chapter 7.5, Article II Sec. 5.C. 2.] 13. The Tree Planting Detail should include a line indicating where the X diameter at breast height (DBH) of the shade tree will be measured at time DEPARTMENTS INCLUDE REJECT of planting and inspection. 14. Cypress mulch cannot be used on the site and reference to this product X should be removed from the notes. 15. There is no irrigation system design included with the site plans. The X irrigation design should be micro-irrigation for water conservation. [Environmental Regulations, Chapter 7.5, Article II Sec. 5A.] 16. Turf areas should be limited in size. Landscape (bedding plants) areas X should be designed on separate zones with proper time duration for water conservation. Environmental Regulations, Chapter 7.5, Article II Sec. 5. C.2.] 17. All trees on the site should receive irrigation from a separate bubbler. X [Environmental Regulations, Chapter 7.5, Article II Sec. 5. C.2.] PLANNING AND ZONING Comments: 18. Clarify through proper labeling of data for required parking to only regard X storage use on parent tract. 19. Map document in application excludes dimension to nearest tower, possibly X shown as a red dot and numbered 8650, or clarify accordingly. Locate correctly search ring number 8650. 20. Provide amended site plan, at time of permit filing, showing compliance I X] with all applicable comments/conditions. 21. Provide access easement agreement with request for permits. [ X I 22. Provide Radio Frequency data from project engineer to document void in I X I coverage and therefore necessity for proposed tower. 23. Provide structural/engineering data to confirm design is capable of X collocation and number of carriers and corresponding heights. Include this information in certification letter from project engineer. 24. Existing fence on south side of proposed lease area and slats are in need X repair. Straighten fence and replace slats behind lease area and behind and around dumpster station (if to remain). 25. Relocation of dumpster(s) may require proper siting and screening in I XI accordance with Land Development Regulations. 26. Existing perimeter hedge is in poor condition and provides limited X screening contrary to approved plan and original intent. Indicate where landscape material will be enhanced to provide required screening. Large voids in the entire perimeter landscaping shall be improved as a condition of approval, with new plantings. 27. Revise certification letter to affirm compliance with all requirements as X stated in Sec. 3.C.2 of Chapter 10., including with height requirements as to be measured from crown of nearest road (or provide survey documentation verifying same). Conditions of Approval 4 DEPARTMENTS INCLUDE REJECT 28. Specifically indicate paint/material color on elevation graphic; include any I XI available material samples and/or swatches. ADDITIONAL PLANNING & DEVELOPMENT BOARD CONDITIONS Comments: 1. None X ADDITIONAL CITY COMMISSION CONDITIONS Comments: 1. To be determined. S:\Planning\SHARED\WP~PROJECTSWerizon Wireless Mega Mini 2951 SW 14th Pl\COA.doc