Loading...
Southern Dance Theater NWSP ( , DEVELOPMENT., (DER OF THE CITY COMMISSIO. )F THE CITY OF BOYNTON BEACH, FLORIDA Development P&Z Building Engineering Occ. License Deputy City Clerk PROJECT NAME: Southern Dance Theatre APPLICANT'S AGENT: Mr, Bradley Miller, Miller Land Planning Consultants, Inc. APPLICANT'S ADDRESS: 420 W, Boynton Beach Blvd., Suite 201, Boynton Beach, FL 33435 DATE OF HEARING RATIFICATION BEFORE CITY COMMISSION: March 21, 2006 TYPE OF RELIEF SOUGHT: New Site Plan (NWSP 06-001) LOCATION OF PROPERTY: DRAWING(S): SEE EXHIBIT "B" ATTACHED HERETO, X THIS MATTER came on to be heard before the City Commission of the City of Boynton Beach, Florida on the date of hearing stated above, The City Commission having considered the relief sought by the applicant and heard testimony from the applicant, members of city administrative staff and the public finds as follows: 1. Application for the relief sought was made by the Applicant in a manner consistent with the requirements of the City's Land Development Regulations. 2. The Applicajlt ~HAS HAS NOT established by substantial competent evidence a basis for the relief requested. 3. The conditions for development requested by the Applicant, administrative staff, or suggested by the public and supported by substantial competent evidence are as set forth on Exhibit "C" with notation "Included". 4. The Applicant's application for relief is hereby ~GRANTED subject to the conditions referenced in paragraph 3 hereof. DENIED 5, This Order shall take effect immediately upon issuance by the City Clerk. 6. All further development on the property shall be made in accordance with the terms and conditions of this order. 7. Other DATED: 0:3-a4-ob J:\SHRDA T AIPlanning\SHARED\WP\PROJECTS\Southern Dance Theatre\NWSP 06-001\DO.doc I I. I rn \ ~/ / T I .1 In. :: 292,0 feet ! I I I r O. .... ." ~ --- IDn "In -- ~ ~ ~ ,,~ ~ ~ NIGV~' ., ... \In ........~ . . ;::SITE ~ 0-..~~ ~~ ... -~ 7 ~ ~ o - anVlITnN t [] . j I I ~ II L:- =11n '11= "-0 f-- ~ J ~ ~ ,.-- . . !~~ 'hi rrY1 ? ~D: II r~Y Exhibit "A" - 1203 Knuth Rd Location Map --"".-=-1. ~_.. December 21, 2005 Ed Breese CIlY OF BOYNTON BEACH PLANNING &. ZONING DEPARTMENT 100 E. Boynton Beach Boulevard Boynton Beach, FL 33425-0310 RE: Southern Dance studio peN 00.43.45.19.05.048.0020 Dear Mr. Breese: This letter is to acknowledge and accept that, I the property owner, will voluntary restrict use of property limited to C-2 Zoning District and any use that has a higher parking requirement. Penni Greenly, Managing Member Southern Dance Theatre, Inc. z .~ .. ~If ~ .m~~~!ll . . . ~......n..U eh hi (Ix i ~ Jjjl,1~ J 1~1!i1 iHIJ~ I ,I II il , ! J Uh 1ft i !Eli J ~ f I I I ,.j · hu , I'lf'''' J ~~ J Iliff IIqlJ !~~~ ; ~ . .! fl. h~ll ~"." !:: ~ i. rl!ifl II "~'U ." - f U!:H!1!t ~~ j HI ! J hJiJ J nHi mu flflll .. ,..,~~--~~~~ t L I fiJ a _~~_____ Cl'I'O" "nH)( --......., . ~.. -=- 11 '4:>099 UOjUA09 10 Atl) ~ olpnlS e:)UDO UJeLunOS f ~ /)/ III I n r I .. , . a " ;,:: i ., I if ! II i I j I' Ii i I' · l I I I ii IIf 31 I , Ii ~ ~lil ! ~ Q & ~ -- ".... . ..... .... 1~~ili;l;ii N~ I I . . Q!l~lj I. ~.'IIII. :! J 41 is 'il I J - , liln ~ II' .. f <I( I ~ ~ ~ !. I '11111 i.' ~I w I II.' i t..1 ; il il ~H ~!! ':ili~ ~ I": 'I, II'! '.,I! a I I I 'II .'t · , I~,) ,. , b" !IIII J if if liII! ill' ~ ~ . c( o t :I... @ I: "~i! i fIlII I I;i~! ; . , I f~! ~~ i ; :. i II 'II i!i.i ,. .1 .< 'I. H 1F-lrU di I Iii ,hll 'I! !~;1~ I~ III 1" filII :U 19!1~ !~ ,,, . . .. .. C! .8 !:/ Ii~ J I . l! ri ~ " . r ~ t r I: I ~Ii: I ii ~I i ... . - z II.! II, I. ~ ;; . '1 I ~ I Iln i: fJ) I, !ft ~ I... : i' 1111 ,8 11. ,1111 " Ir ~ II; I 0 ~ I!!!! , 9 I.. IL. 0 . . w (f) &~ lE~ - ----..------------- -- . .- ---------+------ OVOH H!IlN>f 5 Il.. ~ I · I I I II! ~ i i ,!! ~~~ I ~~Ju gO~41 g~~U J I i .f I I'll, III n !/II/ :lnt ! IiI ~ "III'H IlU .. ] r . I. f. ;f II . J ~ If 'l 8 ~I ~ I I . ~ : ~ ~lj Ii ~i :1 ~ Si I. ~Ir V.. I: Ilc~ 3= >~ -=".., . lI:IIt.. .... I, II; ;::~ ,3111 i ~ h I~ " I ~ i I I ~ It i i i f ~ I J i ~ ~i Ii! ~ ; rf~ i; <!! i!,' ~ ~ ,fa. t ~ II ~ ~ Ii ; ~i~~ I ',. ~B ~ ~ f f ~ :i R ft: ~ t !~ : !Iff '". ,. ! k 1 I. ~! Jl fB ~ j~ h I' dl II! If ~i:t ~ ~t ni~ ~: l fi' %, II g~ ~~ i ~t aIG'. 2t 50 ~!~ ~ ~ I If ~ 'i Ii f fj~!i:. ~ !~ ~~ I II III ~I ! !Ifll 1!1!:ln! kk~~ I ~ !f!f! Iff i I"fti, fif, ~g I ~ ~ ~ ~ ~ ~ = ~ II ;fal f' ~. Ii ~. fa la ~g tr II l!h /IIi /llnl il Ii " I rPil II I I l! IJ~ f Iff I I I f I II U flf Ii 1IIIIIIIIildlllll 1111 If!.f!)11 il ifl I I I.! I f II f i I I 1f1rn f ~~ Ip' fl' I ~ ~<< · I I HIll)' It j,! (f"li I Ill, I I I III II I 1'1 Jilin ,"t:1J d d II .111 . I i {I'fl! 'Jlfi I I I i".lj I .K a l z 4: ~ ~ ~ ~ i ~ ..., -,. II ',1 I i ----- ..-.. .. I I . .. II I ~ I I ~ G!J III . g I' I I J J " I I I o ~ f i ~ ! I: I II i i i I ,I I I .' I I I I. . I . Bll!lEll!lElEll!lml!lI!J ! I I I I I . If " II I E1~~ en I~ : ~ Ilf ~ ~ ',1 r I ~!;!Ifl.fll ~1'1.lllfll ~ I I b r I I I I I ~019E101!J1!J~I!IEl~ I t I I I If IIII I I ' f f . I ~ , u I ! ! ! f I If' I ~ 8888888888 ~ E ~ CI ~ iil ~ ('4' . ; .... II ! I i ~ i -rllil ~ !i I '- ifj P II .1 ~ (!JIll " 3. ~'I' J.... II ., EXHIBIT "C" CONDITIONS OF APPROVAL Project name: File number: Reference: Southern Dance Theatre NWSP 06-00 I 2nd Review Plans identified as a New Site Plan with a December 27,2005 Planning & Zoning d k' ate stamp mar mg. DEPARTMENTS INCLUDE REJECT PUBLIC WORKS- General Comments: None X PUBLIC WORKS- Traffic Comments: 1. Pennits from Palm Beach County will be required for work within the Knuth X Rd, right-of-way. ENGINEERING DIVISION Comments: 2. All comments requiring changes and/or corrections to the plans shall be X reflected on all appropriate sheets. 3. Please note that changes or revisions to these plans may generate additional X comments. Acceptance of these plans during the Technical Advisory Review Team (TART) process does not ensure that additional comments may not be generated by the Commission and at permit review. 4. The provided survey does not depict an existing power line from the west X side of Knuth road into the property for electric service. Please show all features, including utilities, on the survey. 5. Indicate power line relocation/demolition on the site and civil plans. X 6, Show proposed site lighting on the site plan (LDR, Chapter 4, Section 7.BA.). X 7. Provide an Engineer's certification on the Drainage Plan as specified in LDR, X Chapter 4. Section 7,F.2. 8. Full drainage plans, including drainage calculations, in accordance with the X LDR, Chapter 6, Article IV, Section 5 will be required at the time of permitting. Conditions of Approval 2 DEPARTMENTS INCLUDE REffiCT 9, Paving, Drainage and site details will not be reviewed for construction X acceptability at this time. All engineering construction details shall be in accordance with the applicable City of Boynton Beach Standard Drawings and the "Engineering Design Handbook and Construction Standards" and will be reviewed at the time of construction permit application. UTILITIES Comments: 10. All utility easements (as applicable) and utility lines shall be shown on the X site plan and landscape plans (as well as the Water and Sewer Plans) so that we may determine which appurtenances, trees or shrubbery may interfere with utilities. In general, palm trees will be the only tree species allowed within utility easements. Canopy trees may be planted outside of the easement so that roots and branches will not impact those utilities within the easement in the foreseeable future. The LDR, Chapter 7.5, Article I, Section 18,1 gives public utilities the authority to remove any trees that interfere with utility services, either in utility easements or public rights-of-wav. 11. Palm Beach County Health Department permits will be required for the water X and sewer systems serving this project (CODE, Section 26-12), 12. Fire flow calculations will be required demonstrating the City Code X requirement of 1,500 g.p.m. (500 g.p,m. some residential developments) with 20 p.s.i. residual pressure as stated in the LDR, Chapter 6, Article N, Section 16, or the requirement imposed by insurance underwriters, whichever is greater (CODE, Section 26-16(b)), Unless the building is to be sprinklered, one fire hydrant may not meet this reQuirement. 13. The CODE, Section 26-34(E) requires that a capacity reservation fee be paid X for this project either upon the request for the Department's signature on the Health Department application fonns or within seven (7) days of site plan approval, whichever occurs first This fee will be detennined based upon fmal meter size, or expected demand. 14. Water and sewer lines to be owned and operated by the City shall be included X within utility easements, Please show all proposed easements on the engineering drawings, using a minimum width of 12-ft. The easements shall be dedicated via separate instrument to the City as stated in CODE Sec. 26- 33(a), 15. This office will not require surety for installation of the water and sewer X utilities, on condition that the systems be fully completed, and given to the City Utilities Department before the first permanent meter is set. Note that setting of a permanent water meter is a prerequisite to obtaining the Certificate of Occupancy, Indicate meter(s) size on the plans so that reservation fees may be calculated. DEPARTMENTS INCLUDE REJECT 16. A building permit for this project shall not be issued until this Department X has approved the plans for the water and/or sewer improvements required to service this project, in accordance with the CODE, Section 26-15. 17. Utility construction details will not be reviewed for construction acceptability X at this time. All utility construction details shall be in accordance with the Utilities Department's "Utilities Engineering Design Handbook and Construction Standards" manual (including any updates) and will be reviewed at the time of construction permit application. FIRE Comments: 18. Because this will be a place of assembly greater than 1,000 square feet, and X with more than 300 occupant load, an approved NFPA 13 Fire Sprinkler system will be required. This system shall be monitored by an approved central station and receive a Letter of Certification from U.L. or a placard from Factory Mutual. 19. Show the locations of all fire hydrants, move to front of property (200' rule). X POLICE Comments; -None X BUILDING DIVISION Comments: 20. Please note that changes or revisions to these plans may generate additional X comments. Acceptance of these plans during the TART (Technical Advisory Review Team) process does not ensure that additional comments may not be generated by the conunission and at pennit review, 21. Buildings, structures and parts thereof shall be designed to withstand the X minimum wind loads of 140 mph. Wind forces on every building or structure shall be determined by the provisions of ASCE 7, Chapter 6, and the provisions of 2004 FBC, Section 1609 (Wind Loads). Calculations that are signed and sealed by a design professional registered in the state of Florida shall be submitted for review at the time of permit application. 22. Add to all plan view drawings of the site a labeled symbol that represents the X location and perimeter of the limits of construction proposed with the subject request. 23. At time of permit review, submit signed and sealed working drawings of the X proposed construction. Conditions of Approval 4 DEPARTMENTS INCLUDE REJECT 24, Add to the building that is depicted on the drawing titled site plan and floor X plan a labeled symbol that identifies the location of the handicap-accessible entrance door/s to the building. 2004 FBC, Sections 11-4.1.2, 11-4.1.3, and 11-4.3. 25. Identify within the site data the finish floor elevation (lowest floor elevation) X that is proposed for the building. Verify that the proposed elevation is in compliance with regulations of the code by adding specifications to the site data that address the following issues: A. The design professional-of-record for the project shall add the following text to the site data. "The proposed finish floor elevation _' _ NGVD is above the highest 100-year base flood elevation applicable to the building site, as determined by the SFWMD's surface water management construction development regulations," B. From the FIRM map, identify in the site data the title of the flood zone that the building is located within. Where applicable, specify the base flood elevation. If there is no base flood elevation, indicate that on the plans. C, Identify the floor elevation that the design professional has established for the building within the footprint of the building that is shown on the drawings titled site plan, floor plan and pavinwdrainage (civil plans). 26. On the drawing titled site plan identify the property line. X 27. CBBCPP 3.C.3.4 requires the conservation of potable water. City water may X not, therefore, be used for landscape irrigation where other sources are readily available, 28, A water-use permit from SFWMD is required for an irrigation system that X utilizes water from a well or body of water as its source. A copy of the permit shall be submitted at the time of permit application, F,S, 373.216, 29, If capital facility fees (water and sewer) are paid in advance to the City of X Boynton Beach Utilities Department, the following information shall be provided at the time of building permit application: A, The full name of the project as it appears on the Development Order and the Commission-approved site plan. B. The total amount paid and itemized into how much is for water and how much is for sewer, (CBBCO, Chapter 26, Article II, Sections 26-34) 30. At time of permit review, submit separate surveys of each lot, parcel, or tract. X For purposes of setting up property and ownership in the City computer, provide a copy of the recorded deed for each lot, parcel, or tract. The recorded deed shall be submitted at time of permit review. DEPARTMENTS INCLUDE REJECT 31. Pursuant to approval by the City Commission and all other outside agencies, X the plans for this project must be submitted to the Building Division for revi ew at the time of permit application submittal. The plans must incorporate all the conditions of approval as listed in the development order and approved by the City Commission. 32. The full address of the project shall be submitted with the construction X documents at the time of permit application submittal. If the project is multi- family, then all addresses for the particular building type shall be submitted. The name of the project as it appears on the Development Order must be noted on the building permit application at the time of application submittal. 33. This structure meets the definition of a threshold building per F,S. 553.71 (7) X and shall comply with the requirements of F.S. 553.79 and the CBBA to the 2004 FBC, Sections 109.3.6.1 through 109.3,6.6. The following information must be submitted at the time of permit application: A. The structural inspection plan must be submitted to the enforcing agency prior to the issuance of a building permit for the construction of a threshold building. B. All shoring and re-shoring procedures, plans and details shall be submitted. C. All plans for the building that are required to be signed and sealed by the architect or engineers of record shall contain a statement that, to the best of the architect's or engineer's knowledge, the plans and specifications comply with the applicable fire safety standards as determined by the local authority in accordance with this section and F.S. Section 633. 34. Clearly show the setback for the building on the north side. X PARKS AND RECREATION Comments: None X FORESTERlENVIRONMENTALIST . Comments: 35. The Landscape Architect should tabulate the total caliper inches of trees to be X preserved, relocated or removed / replaced on the site. The replacement trees should be shown by a separate symbol on the landscape plan sheet L-I. fEnvironmental Regulations, Chapter 7.5, Article I See, 7.D.p. 2,] 36. The applicant should show the calculated 50% native species of trees, and X shrubs, PLANNING AND ZONING 37. Provide a notice of concurrency (Traffic Performance Standards Review) X from Palm Beach County Traffic Engineering. The traffic impact analysis must be approved by the Palm Beach County Traffic Division for concurrency purposes prior to the issuance of any buildin2 Permits, Conditions of Approval 6 DEPARTMENTS INCLUDE REJECT ADDITIONAL PLANNING & DEVELOPMENT BOARD CONDITIONS Conunents: 1. None X ADDITIONAL CITY COMMISSION CONDITIONS Conunents: 1. To be detennined. ~ S:\PlanningISHAREDI WPIPROJEcrSlSouthem Dance TheatreINWSP 06-00 IICOA.doc