R96-156RESOLUTION NO. R96o/-4~
A RESOLUTION OF THE CITY COMMISSION OF THE
CITY OF BOYNTON BEACH, FLORIDA CONFIRMING
AND RATIFYING THE APPROPRIATE EXHIBITS
HERETOFORE REFERENCED IN ORDINANCE 096-40;
AND PROVIDING AN EFFECTIVE DATE.
and
WHEREAS, the City adopted Ordinance 096-40, on the 4th day of September, 1996;
WHEREAS, Ordinance NO 096-40, contained a reference to certain Exhibits, which
were attached to said Ordinance; and
WHEREAS, the City Commission wishes to ratify its action and confirm that the
proper Exhibits are attached to the official records of the City of Boynton Beach.
NOW THEREFORE, BE IT RESOLVED BY THE CITY COMMISSION OF THE
CITY OF BOYNTON BEACH, FLORIDA, THAT:
Section 1. The attached '~Exhibit B" to this resolution is the Exhibit B heretofore
referenced in Ordinance No. 096-40 and the City Clerk is hereby directed to attach said
Exhibit B to Ordinance No. 096-40.
Section 2. The attached "Exhibit C" to this resolution is the Exhibit C heretofore
referenced in Ordinance No. 096-40, and the City Clerk is hereby directed to attach said
Exhibit C to Ordinance No. 096-40.
Section 3. The attached "Chapter 4" to this resolution is the Exhibit entitled
"Chapter 4" heretofore referenced in Ordinance No. 096-40, and the City Clerk is hereby
directed to attached said "Chapter 4" to Ordinance No. 096-40.
Section4. That this Resolution shall become effective immediately upon
passage.
PASSED this/~-,-,~ day of October, 1996.
CITY OF BOYNTON BEACH, FLORIDA
Mayor
Vice Mayor
/
Commissioner
Co~ssioner
ATTEST:
City Clerk
EXHIBIT "B"
CHAPTER 1
ADMINISTRATION
100 INCORPORATION OF STANDARD. The Boynton Beach Administrative Code is
adopted in Exhibit "A" and is incorporated as if herein to provide for the administrative
aspects of this Exhibit as follows:
Part 1
Part 2
Part 3
Part 4
Part 5
Amendments to the Standard Building Code, 1994 Edition
Amendments to the Standard Gas Code, 1994 Edition
Amendments to the Standard Plumbing Code, 1994 Edition
Amendments to the Standard Mechanical Code, 1994 Edition
Amendments to the NatiOnal Electrical Code, 1996 Edition
PART I - AMENDMENTS TO THE STANDARD BUILDING CODE, 1994 EDITION
CHAPTER 2
DEFINITIONS
202 DEFINITIONS
AGENCY - means same as applicable governing body.
FLOOR ELEVATION - minimum ground floor elevation for all buildings to be six inches
above sidewalk and crown of road unless satisfactory drainage, natural or mechanical,
is provided. Mandatory flood plain, Coastal Zone Protection Act of 1958, South Florida
Water Management District elevation, and septic tank requirements, must all be
adhered to.
GOVERNING BODY - means same as Applicable Governing Body.
MANUFACTURERS RECOMMENDATION - as used in Chapter 15 shall mean a
published or written document by the product manufacturer.
CHAPTER 3
OCCUPANCY CLASSIFICATION
306 EDUCATIONAL OCCUPANCY-GROUP E
306.1.5 CHILD AND FAMILY CARE FACILITIES. The following sources also contain
rules and regulations concerning the construction of child and family care facilities, and are
enforced by the local Fire Official and Health Department.
Laws of FlOrida - Chapter 59-1698
Laws of Florida - Chapter 77-620
EXHIBIT "C"
PART 5 - AMENDMENTS TO THE NATIONAL ELECTRICAL CODE, 1996 EDITION
ARTICLE 90 - INTRODUCTION
90-10 - INCORPORATION OF STANDARD
The Boynton Beach Administrative Code is adopted in Exhibit "A" and is incorporated as if herein to
provide for the administrative aspects of the National Electrical Code, 1996 Edition.
CHAPTER 1. General
ARTICLE 100 - DEFINITIONS
Scope. This article contains only those definitions essential to the proper application of this Code. It is
not intended to include commonly defined general terms or commonly defined technical terms from
related codes and standards. In general, only those terms used in two or more articles are defmed in
Article 100. Other definitions are included in the article in which they are used but may be referenced in
Article 100.
Part A of this article contains definitions intended to apply wherever the terms are used throughout this
Code. Part B contains definitions applicable only to the parts of articles specifically covering
installations and equipment operating at over 600 volts, nominal. All the definitions as listed in the
latest edition of the Standard Building Code shall be a part of this Code.
A. General
And/Or: in a choice of two code provisions, signifies that use of both provisions will satisfy the code
requirement and use of either provision is acceptable also.
CHAPTER 2. WIRING DESIGN AND PROTECTION
ARTICLE 210 - BRANCH CIRCUITS
A. General Provisions
210-1 Scope. The provisions of this article apply to branch circuits supplying lighting or appliance
loads or combinations of both. Where motors or motor-operated appliances are connected to any branch
circuit that also supplies lighting or other appliance loads, the provision of both this article and article
430 shall apply. Article 430 applies where a branch circuit supplies motor loads only. Branch circuits
shall be plainly marked at the overcurrent protective device so that they can be quickly and positively
identified.
Exception: Branch circuits for electrolytic cells as covered in Section 668-3(c). Exceptions No.
1 and 4.
CHAPTER 4
PLUMBING FIXTURES
409.8 SHOWER COMPARTMENTS
409.8.2 CONSTRUCTION Floors under shower compartments shall be laid on a smooth and
structurally sound base and shall be lined and made watertight with sheet lead, copper or other
acceptable materials. Shower compartments located in basements, cellars, or in other rooms in
which the floor has been laid directly on the ground surface need not be lined.
Pan liners for built-in-place tubs shall also be made of lead, copper or other approved material
and shall extend to a point 2 inches above the tub overflow. All lead and copper pans where in
contact with masonry materials shall be protected against deterioration by completely coating
with an asphalt base material, type 30 felt paper or other approved material.
Under the following conditions, shower compartments and built-in- place tubs are not required to
have pans; on the first floor only where the floor construction consists of concrete, the pan may
be formed by recessing the shower floor at least 4 inches -¢ below the rough floor line in the case
of a shower enclosure; or by recessing the floor for a built-in-place tub so that the tub overflow is
2 :inches below the rough floor line. For shower compartment not over 6 inches 4- deep, floor
recess shall be poured monolithically with the floor slab. The floor recess must be totally
contained within the concrete floor slab. Block walls are not allowed to be part of any floor
recess, less than -¢ 6 ", unless a pan liner is installed.
CHAPTER 5
WATER HEATERS
503 STANDARDS
503.4 WATER HEATER TEMPERATURE CONTROL SETTING - Water heater
temperature shall conform to State of Florida Model Energy Code, as amended.
507 SAFETY DEVICES
507.6 RELIEF OUTLET WASTE The outlet of a pressure, temperature, or other relief valve
shall not be directly connected to the drainage system. The pressure and temperature relief valve
drain lines shall not be connected into condensate waste lines from air conditioning equipment.
The drain piping from pressure, temperature or other relief valves may be discharged as follows:
Solar hot water storage tanks or solar collectors placed above the roof may
discharge upon the roof surface, as stated in 2 and 3.
In cases where a building covers an entire lot, or has a mechanical equipment
room, the discharge shall be to any suitable plumbing fixture (except a water
closet) or floor drain terminating above the floor level.
3