Loading...
Agenda 02-25-14 CITY OF BOYNTON BEACH PLANNING & DEVELOPMENT BOARD MEETING AGENDA DATE: Tuesday, February 25, 2014 TIME: 6:30 P.M. PLACE:Commission Chambers, 100 E. Boynton Beach Boulevard, Boynton Beach, Florida ___________________________________________ __________________________ ___________ 1. Pledge of Allegiance 2. Introduction of the Board 3. Agenda Approval 4. Approval of Minutes from January 28, 2014 meeting 5. Communications and Announcements: Report from Staff 6. New Business: iStorage Center (NWSP 14-001) A.– Approve request for new site plan approval to construct a one-story, 6,200 square foot retail/office building and related site improvements, located at 3008 South Congress Avenue, and zoned M1 (Light Industrial). Applicant: Bradley Miller, Miller Land Planning, Inc. B.Boynton Old School Commercial Center (LUAR 14-001) – Approve the Boynton Old School Commercial Center (LUAR 14-001) reverting the land use classification on the subject property from Mixed Use (MX) to Public and Private Governmental/Institutional (PPGI) through the rescission of Ordinance 13-014 to return the Future Land Use classification to that which coincides with the current zoning of the property, Public Usage (PU). Applicant: City-initiated. 7. Other 8. Comments by members 9. Adjournment The Board (Committee) may only conduct public business after a quorum has been established. If no quorum is established within twenty minutes of the noticed start time of the meeting the City Clerk or her designee will so note the failure to establish a quorum and the meeting shall be concluded. Board members may not participate further even when purportedly acting in an informal capacity. NOTICE ANY PERSON WHO DECIDES TO APPEAL ANY DECISION OF THE PLANNING AND DEVELOPMENT BOARD WITH RESPECT TO ANY MATTER CONSIDERED AT THIS MEETING WILL NEED A RECORD OF THE PROCEEDINGS AND FOR SUCH PURPOSE MAY NEED TO ENSURE THAT A VERBATIM RECORD OF THE PROCEEDING IS MADE, WHICH RECORD INCLUDES THE TESTIMONY AND EVIDENCE UPON WHICH THE APPEAL IS TO BE BASED. (F.S. 286.0105) THE CITY SHALL FURNISH APPROPRIATE AUXILIARY AIDS AND SERVICES WHERE NECESSARY TO AFFORD AN INDIVIDUAL WITH A DISABILITY AN EQUAL OPPORTUNITY TO PARTICIPATE IN AND ENJOY THE BENEFITS OF A SERVICE, PROGRAM, OR ACTIVITY CONDUCTED BY THE CITY. PLEASE CONTACT THE CITY CLERK’S OFFICE, (561) 742-6060 AT LEAST TWENTY (24) HOURS PRIOR TO THE PROGRAM OR ACTIVITY IN ORDER FOR THE CITY TO REASONABLY ACCOMMODATE YOUR REQUEST. (SGYQIRX NEW BUSINESS 6.A iStorage Center (NWSP 14-001) New Site Plan Staff Report – iStorage Center (NWSP 14-001) Memorandum No PZ 14-004 Page 2 East: Developed property consisting of a self-storage facility, with an Industrial (I) future land use classification, and zoned Light Industrial (M1); and West: Right-of-way for Congress Avenue, and farther west is a developed property consisting of a physical therapy rehabilitation facility (Manor Care), with a Local Retail Commercial (LRC) future land use classification, and zoned Community Commercial (C-3). Site Details: The subject site is vacant and is located on the east side of Congress Avenue, th approximately 500 feet north of SW 30 Avenue. The property is owned by the same company that owns the storage facility directly east of the parcel, and they desire to connect the two properties through an ingress/egress point from Congress Avenue for purposes of improved access and greater visibility. As part of the project, the property owner proposes to move their business office into the new building for greater exposure and ease of access. BACKGROUND Proposal: Bradley Miller, of Miller Land Planning, Inc., representing Storage Quest Boynton Beach LLLP, is requesting site plan approval to construct a one-story, 6,200 square foot retail/office building and related site improvements. Certain retail and office uses are permitted by right on parcels zoned M1 (Industrial), provided they are 1) located in a multi-tenant building situated on a parcel fronting an arterial or collector roadway (such as Congress Avenue); 2) individual tenant space does not exceed 5,000 square feet in size; 3) the use excludes a drive-through component; and lastly, the use must be able to comply with the off-street parking requirements. These regulations were adopted as a result of the M1 Corridor Study, in an effort to create a more attractive streetscape along our larger thoroughfares, as opposed to industrial operations with outside storage and open overhead bay doors. Additionally, the revised regulations make provisions for convenience type office and retail uses on the fringe of employment and residential areas to reduce the amount of traffic and length of vehicular trips. th This parcel is the last of the vacant land between SW 30 Avenue and the L.W.D.D. L-28 canal to be developed. The parcels immediately south of this site were developed as part of a phased project, beginning with the approval of a three (3) story limited-access self-storage building at the south end of the parcel in 2003. Phase II, a carwash facility situated between the storage facility and the applicant’s parcel, was approved in 2006. The carwash was approved as a Conditional Use, after preparing a sound study and providing additional landscape buffering to ensure compliance with the City’s noise ordinance. Finally, in 2008, the third phase, a contractors office with storage (not fronting on Congress Avenue) was approved immediately west of the carwash parcel. ANALYSIS Concurrency: Traffic: A traffic statement for the proposed project was sent to the Palm Beach County Traffic Division for concurrency review in order to ensure an adequate level of Staff Report – iStorage Center (NWSP 14-001) Memorandum No PZ 14-004 Page 3 service. A traffic concurrency approval letter was received from Palm Beach County indicating that two (2) AM peak hour trips and 32 PM peak hour trips would be generated as a result of this project and that no permits are to be issued after the build-out date of 2016. School: School concurrency is not required for this type of project. Utilities: The City’s water capacity, as increased through the purchase of up to 5 million gallons of potable water per day from Palm Beach County Utilities, would meet the projected potable water for this project. Sufficient sanitary sewer and wastewater treatment capacity is also currently available to serve the project, subject to the applicant making a firm reservation of capacity, following site plan approval. Police / Fire: Staff reviewed the site plan and determined that current staffing levels would be sufficient to meet the expected demand for services. Drainage: Conceptual drainage information was provided for the City’s review. The Engineering Division has found the conceptual information to be adequate and is recommending that the review of specific drainage solutions be deferred until time of permit review. Lake Worth Drainage District (L.W.D.D.) has also reviewed the plans and requested the applicant provide a five (5) foot easement immediately abutting their canal right-of-way. The applicant has depicted the proposed five (5) foot easement on the site plan per L.W.D.D. request. Prior to issuance of a L.W.D.D. permit, the applicant will be required to record the easement in County records. Vehicular Access: The site plan (Sheet SP-1) shows that two (2) primary points of ingress/egress are proposed for the new building. The first, a right-in/right-out driveway opening from Congress Avenue, would occur at the southwest corner of the parcel within a 25 foot wide ingress/egress easement located between this parcel and the carwash to the south. This easement was required at the time of approval of the carwash project. A second point of ingress/egress is an existing full driveway opening along th SW 30 Avenue, south of the parcel. This access was required during the approval of the three (3) story limited-access self-storage building to the south and extended to this site during approval of the carwash property. A point of inter-parcel access is proposed between the existing single story self-storage facility to the east and the subject site, both under same ownership, as part of a Minor Site Plan Modification subsequent to approval of this proposed site plan. Prior to the construction of the proposed bridge and culvert within the drainage easement, the property owner will be required to record a hold harmless agreement in the County records, once approved by the City Attorney (see Exhibit “C” – Conditions of Approval). The requirements for a dumpster and truck loading zone have been reviewed and approved by the Engineering Division with the submittal of truck turning radius diagrams by the applicant. Circulation: Vehicular circulation from each driveway would include two-way circulation that continues throughout the parking lot. Pedestrian connectivity would be provided on site via a walkway that would extend from the east and south sides of the building, where tenant entries would be, and connect with the sidewalk along South Congress Avenue. A covered bike rack is proposed on the south side of the building, between tenant entrances. Staff Report – iStorage Center (NWSP 14-001) Memorandum No PZ 14-004 Page 4 Parking: The site plan (Sheet SP-1) proposes a 6,200 square foot office/retail building, which would require 31 parking spaces maximum if the entire 6,200 square feet was devoted to retail. The required number of parking spaces is based upon the standard of one (1) parking space per 200 square feet of building, as opposed to one (1) space per 300 square feet for office use. The site plan depicts 31 parking spaces, including two (2) designated for handicap use. All proposed parking stalls, including the size and location of the handicap space, were reviewed and approved by both the Engineering Division and Building Division. In addition, all necessary traffic control signage and pavement markings will be provided to clearly delineate areas on site and direction of circulation. Landscaping: The landscape plan (Sheet L-1) indicates compliance with the required minimum buffers around the perimeter of the site. A seven (7)-foot wide buffer is proposed adjacent to South Congress Avenue and a five (5)-foot wide buffer along the south and east property lines. Along the north property line, adjacent to the L.W.D.D. canal and residential development farther north, the landscape plan indicates a 12- foot wide buffer that includes a six (6)-foot high buffer wall. The wall will have decorative columns, cap, and offsets to comply with the monotony restrictions, as well as a Marlberry hedge at 36” in height and Jamaican Caper shrubs 48” in height planted in the offsets along the exterior of the wall. On the interior of the wall, the north buffer will consist of Live Oak, Green Buttonwood, and Sabal Palm trees. These canopy trees would be planted at 16 feet in height and the Sabal palms would be 20 feet in height, in an effort to provide a substantial screen as part of the required Type II Buffer. The landscaping scheme provides the aforementioned canopy and palm trees, as well as Silver Buttonwood, East Palatka Holly and Alexander Palm trees. Typical shrubs would include Horizontal and Red Tip Cocoplum, Copperleaf, Florida Privet, Podocarpus, and Firebush. The pervious area would total 44% of the entire site and consists of landscaped and open space areas. The landscape code requires that 50% or more of the plant material be native species or low to medium water demand varieties. The plant list (Sheet L-1) indicates that 75% of the trees would be native species. Also, the landscape plan indicates that a total of 99% of shrubs would be categorized as low to medium water demand. The code also limits the use of sod to larger open spaces for passive or active recreation purposes, as well as swales, water detention and retention areas, in an effort to reduce water consumption. The applicant has reduced the amount of sodded areas from the original submittal, limiting placement to the canal banks and the sloped area between the building and the Congress Avenue sidewalk. As the landscape area between the building and the sidewalk along Congress Avenue does not fit one of these categories, staff is recommending a condition of approval to replace the proposed sod with a hearty groundcover or variety of shrub material (see Exhibit “C” – Conditions of Approval). Building and Site: The proposed building is designed as a one (1)-story structure with parapet walls at two (2) varying heights to provide architectural character to the structure. The proposed building placement complies with the minimum setbacks of the M1 zoning district, which are 15 feet for the front and sides and 20 feet for the rear yard setback. The proposed building would be setback 37 feet from the north property line, with the additional 80 foot wide L.W.D.D. canal right-of-way further separating it from residentially zoned property. There is also a six (6) foot tall wall Staff Report – iStorage Center (NWSP 14-001) Memorandum No PZ 14-004 Page 5 with landscaping on both sides providing further buffering. As noted previously, the applicant proposes to bridge the drainage easement to the east and provide a driveway connection to their existing storage property. The floor plan (Sheet A2.01) indicates the proposed building is designed to be utilized by up to five (5) tenants, with tenant spaces proposed between approximately 1,000 and 1,400 square feet. One of the tenants proposed for the space includes the business office for the single story self-storage facility to the east (iStorage), since a connection is proposed between the two (2) properties. The floor plan, as designed, would allow for the combination of proposed tenant spaces, thereby reducing the total number of tenants. Building Height: The building elevations (Sheet A3.01) indicate the highest point of the structure would be 24 feet – 8 inches in height, with the typical parapet wall at 20 feet – 8 inches, and the roof deck at a height of 16 feet – 8 inches, well below the maximum of 45 feet allowed in the M1 zoning district, and below the maximum 45 feet allowable height of the residential district to the north, across the canal. Design: The proposed building utilizes many similar design features as other area retail/office buildings, including neutral colors. According to the “Materials Schedule” shown on Sheet A3.01, the main body paint colors of the building would be a light cream and light tan “Modest White” – SW 6084 and “Sand Dollar” – SW 6099 respectively. The base color for the building is proposed as a medium tan “Dapper Tan” – SW 6144. The accent color of the cornice and trim above would be white “Extra White” – SW 7006. The elevations show that the parapet roof would vary in height to give architectural character to the building and help define tenant spaces. Storefront glass is proposed on the east, south and north sides of the building, with glass doors and sidelights on most of the west building façade. All facades depict red standing seam metal canopies over the windows and doors. Public Art: The applicant has indicated they have not selected the proposed artwork or artist at this time. The proposed development of the site is anticipated to cost $700,000, which places the value of any artwork for the site at approximately $4,900. Ultimate review and approval of the artist and artwork would be under the purview of the Arts Commission. Site Lighting: The photometric plan (Sheet PP-1) proposes a total of six (6) freestanding lights in the parking lot. The freestanding lights would be fiberglass pole light fixtures painted black and 15 feet in height. Additional exterior lighting would be building mounted at a height not to exceed 15 feet. Per Chapter 4, Article VII., Section 3.C. of the Land Development Regulations, all proposed lighting shall be shielded to direct light down and away from adjacent properties and rights-of-way. The height of the pole and wall fixtures was chosen to mitigate any light trespass onto the residential properties over 100 feet away, and in conjunction with the landscape buffer on the north property line, there should be no adverse impacts. Signage: Wall signage would consist of non-internally illuminated aluminum sign faces with 3M vinyl graphics. iStorage signage would be red and black background with white letters. All other tenants would have the same type and material sign, with red background and white letters, each utilizing the Arial font. The signs will be externally illuminated by a light bar installed beneath the sign panel. Staff Staff Report – iStorage Center (NWSP 14-001) Memorandum No PZ 14-004 Page 6 recommends the light bar proposed to be placed underneath the tenant signs for external illumination be designed in such a manner as to obscure the light source from view from off the premises (see Exhibit “C” – Conditions of Approval). Tenant sign square footage will be calculated based upon one (1) square foot of sign per one (1) lineal foot of tenant frontage. There is no monument sign planned for the site at this time. RECOMMENDATION The Development Application Review Team (DART) has reviewed this request for new site plan approval and recommends approval contingent upon satisfying all comments indicated in Exhibit “C” – Conditions of Approval. Any additional conditions recommended by the Board or City Commission shall be documented accordingly in the Conditions of Approval. S:\Planning\SHARED\WP\PROJECTS\iStorage Center\NWSP 14-001\Staff Report.doc EXHIBIT "A" - SITE LOCATION MAP iStorage Center (NWSP 14-001) PUD R-1AA R-3 PU SITE C-3 R-3 M-1 REC 5 27002705408101,080135 Feet %6',-8)'896)-2'%66% ,%630(89880))08898(036%, %(-630*,'%)&2382=3&):%77)6+23' %%  6)82)'0-%8)6)+%6387- &3=2832&)%',*036-(% 7398,*)()6%0,;=79-8) NEW BUSINESS 6.B Boynton Old School Commercial Center (LUAR 14-001) Land Use and Rezoning Page 2 The Boynton Old School Commerical Center LUAR 14-001 East: Schoolhouse Children’s Museum and Learning Center, and Kids Kingdom park, classified Public and Private Governmental/ Institutional (PPGI) and zoned Public Usage (PU); West: Right-of-way for Seacrest Boulevard; and farther west First United Methodist Church, classified Low Density Residential (LDR) and High Density Residential (HDR) and zoned R-3 (Multi-Family Residential) and R-1A (Single-Family Residential). BACKGROUND AND RECOMMENDATION On June 18, 2013 the City Commission adopted Ordinance No. 13-014, which reclassified the land use of the property from Public and Private Governmental/Institutional (PPGI) to Mixed Use (MX). However, the City Commission did not approve the city-initiated request for rezoning of the property from Public Usage (PU) to Mixed Use Low Intensity 1 zoning district or the applicant’s request for a Major Site Plan Modification. The adoption of subject ordinance contemplated a public/private partnership and transfer of real property that did not occur. Therefore, staff supports rescinding of Ordinance No. 13-014 to revert the site to the original Public and Private Governmental/Institutional future land use classification. S:\Planning\SHARED\WP\PROJECTS\Boynton Old School Commercial Center\LUAR 14-002\Staff Report.doc 2 EXHIBIT "A" - SITE LOCATION MAP (LUAR 13-002) BOYNTON OLD SCHOOL COMMERCIAL CENTER R-1A NE 3RD AVE R-2 R-2 C-2 C-3 E BOYNTON BEACH BLVD C-2C-3 CITY HALL PU NE 1ST AVE R-1A SITE R-3 PU W OCEAN AVEE OCEAN AVE REC R-3 R-2 SE 1ST AVE PU R-1A  7507515022530037.5 Feet