Loading...
90-GGGGRESOLUTION NO. 90-d~d~ A RESOLUTION OF THE CITY COMMISSION OF THE CITY OF BOYNTON BEACH, FLORIDA, AUTHORIZING AND DIRECTING THE MAYOR AND CITY CLERK TO EXECUTE A CERTAIN INTERLOCAL AGREEMENT BETWEEN PALM BEACH COUNTY AND THE CITY OF BOYNTON BEACH FOR THE PURPOSE OF REIMBURSING THE CITY $51,250.00 FOR KITCHEN EQUPMENT INSTALLED IN THE BOYNTON BEACH CHILD CARE CENTER, A COPY OF SAID INTERLOCAL AGREEMENT BEING ATTACHED HERETO AS EXHIBIT "1"; PROVIDING AN EFFECTIVE DATE; AND FOR OTHER PURPOSES. NOW, THEREFORE, BE IT RESOLVED by the City Commission the City of Boynton Beach, Florida, that: Section 1. The Mayor and City Clerk are hereby ized and directed to execute that certain Interlocal reement, a copy of which is attached hereto as Exhibit Section 2. This immediately upon passage. Resolution shall take effect PASSED AND ADOPTED this day of June, 1990. CITY yor °mmissi°~ , DA Clerk Commissioner (Corporate Seal) RESOLUTION NO. 90-dg~ A RESOLUTION OF THE CITY COMMISSION OF THE CITY OF BOYNTON BEACH, FLORIDA, AUTHORIZING AND DIRECTING THE MAYOR AND CITY CLERK TO EXECUTE A CERTAIN INTERLOCAL AGREEMENT BETWEEN PALM BEACH COUNTY AND THE CITY OF BOYNTON BEACH FOR THE PURPOSE OF REIMBURSING THE CITY $51,250.00 FOR KITCHEN EQUPMENT INSTALLED IN THE BOYNTON BEACH CHILD CARE CENTER, A COPY OF SAID INTERLOCAL AGREEMENT BEING ATTACHED HERETO AS EXHIBIT "1"; PROVIDING AN EFFECTIVE DATE; AND FOR OTHER PURPOSES. NOW, THEREFORE, BE IT RESOLVED by the City Commission of the City of Boynton Beach, Florida, that: Section 1. The Mayor and City Clerk are hereby authorized and directed to execute that certain Interlocal Agreement, a copy of which is attached hereto as Exhibit Section 2. This Resolution immediately upon passage. PASSED AND ADOPTED this ATTEST: shall take effect ..~'~ day of June, 1990. / /~ayor Commissioner ~ , Commissioner · i~y Clerk (Corporate Seal) I AGREEMENT BETWE1 ATE P , BEACH COUNTY AND THE CITY OF BOYNTON 113'3 B 113'3 107 day and entered into this AI, AGR EEMEN T , made COUNTY OF PALM BEACH, THIS INTERLOC 1990 by and bet ween t he JUL 1 a 1 99 � � ners, the ( "COUNTY ) and the CITY OF BOYNTON of o f Commissi• the ( "CITY " by its Board ality, BEACH, an incorporated municip W I T N E S S E T H amended, authorizes t use of Chapter 163, Florida Statutes, as s WHEREAS. e such that ental units to make the mos basis o ffmutuaI advantagt,lE;s power local governor cooperate on a Agreement; by enabling them to coop the CITY and the COUNTY are authorized to enter into this g and WHEREAS, Chapter 125, Florida Statutes, ,unitswfor the COUNTY to enter into agreements with other governmental er agreements by one unit in behalf of the other joint performance or P and empowers a the COUNTY to establish their authorized programs d functions, and projects with other governmental entities; and administer ster p g and WHEREAS, the COUNTY has operated a joint Federally / Ccunty funded Child Care Center as part of the Head Start Program, in a building owned by the CITY at 909 Northeast Third Street, Boynton Beach, Florida; and WHEREAS, as part of the reconstruction and refurbishing of the building by the CITY, the COUNTY budgeted $51,250 of the joint Federal /County funds to assist in paying for certain kitched equipment and kitchen renovations; and WHEREAS, the CITY authorized installation of the kitchen equipment and has made payment to the Contractor and has now requested repayment from the COUNTY; NOW THEREFORE, in consideration of these premises and the mutual promises contained herein, the parties agree as follows: 1. All the food service equipment identified in the CITY's change order No. 1, dated January 6, 1988, to the Lear Group, Inc. has beer installed to the satisfaction of the CITY and the CITY has mad( full payment therefore. The specific items are listed on Exhibii A attached hereto and hereby incorporated by referenced. 2. Upon execution of this Agreement and verification by the COUNT that each item listed on Exhibit A has been installed, the COUNT will reimburse the CITY in the amount of fifty -one thousand tw hundred and fifty dollars ($51,250), less any discounts or adjustment taken by the CITY. 3. The CITY hereby transfers all rights, title and interest in tr items listed on Exhibit A to the COUNTY and the United State Government, as their interests may appear and shall permit the COUNT to property tag or otherwise identify such items as COUNTY property. 4. It is the intention of the parties to enter into a separate lea: agreement either directly or through Boynton Beach Child Care Cente Inc. ( a not - for - profit corporation) for use by the COUNTY of facility as a child care center for the Head Start Program. 5. The COUNTY may in its sole discretion at any time remove the identified in Exhibit A from the premises for use at cther locat consistent with its obligations to the Federal government Federal funds. 6. Any use of the equipment by other than authorized COUNTY e must be specifically approved in writing by the COUNTY's d' representative. 7. Unless otherwise specified herein, all notices given under this Agreement shall be made and transmitted in writing to: COUNTY - Palm Beach County Director of Community Services 301 Evernia Street West Palm Beach, Florida 33401 CITY - City of Boynton Beach City Manager 120 East Boynton Beach Blvd. Boynton Beach, Florida 33435 IN WITNESS WHEREOF, the parties have caused this Agreement to be authorized and executed by their respective governing bodies as of the year and day first written above. / 7 // ATTEST : CITY Off' "4 '✓ B;e: - _ ., ,iii , ice/ 11G . �_, By i P wED • r R^•�: / Gene Moore „R, i '�" Typed Name EY / ' Mayor v I;- ATTEST PALM BEACH COUNTY BOARD OF COUNTY JOHN B. DUNKLE, Clerk COMMISSIONERS C, 1 BY r' ._ 1�(1- - BY E / .�,'- � �' V Chai JUL Z 0 MC AP•ROVED FOR LEGAL SUFFICIENCY i .unty Attorney EXHIBIT "A" Page 1 of 3 KITCHEN EQUIPMENT LIST BOYNTON BEACH CHILD CARE CENTER ITEM MAKE SERIAL NUMBER 1. Range Furnished by others Not found (existed, contractor re- installed and converted to natural gas) 2. Oven, convection, Furnished by others Not found natural gas fired South Bend Magic Air (existed, contractor re- installed and converted to natural gas) 3. Hood Custom Built by contractor Not found (Designed to cover open flame equipment, extending over sides and front a minimum of 6" in compliance with NFPA standard 96. Filters, removable grease trap, residue trap with cleanout at base of riser) - 4. Dishwasher, Hobart C -44 33290 -J electric (Purchased and installed by Contractor) 5. Soiled Dish Table Custom Built by Contractor Not found (Major area 96" by 24" with continuous 6" integral backsplash, welded closed and diagonal backsplash and return to Dishwasher. All service lines, operating components, mechanical and electric devices shall be enclosed. Openings shall be provided for waste disposal and pre -rinse unit and both installed. Sound deaden underside of work surfaces. conform to NSP standards) 6. Pre -rinse and garbage Waste King Universal 881200305 disposal Model 1000 -3 (Purchased and installed by Contractor w / #9 spray rinse, siphon breaker, vol -temp assembly, globe valve, all tubing and piping; 12" bowl and accessories, group APS) 7. Clean Dish Table Custom Built by Contractor Not found (Major area 96" by 24" with continuous 6" integral backsplash, welded closed and diagonal backsplash and return to dishwasher. All service lines, operating components, mechanical and electric devices shall be enclosed. Sound deaden underside of work surfaces. Conform to NSP standards. Provide continuous undershelf to be fastened to support members) 8. Shelves Custom Built by Contractor Not found (To be built above clean dish table: stainless steel, 18 gauge, same construction as for tables. Design shelves and install to support 40 lbs. per sq. ft. loading plus 100% impact loading) 9. Walk -in Cooler - Freezer American Panel 16237 Model WF- 3X -78 -1 (Custom designed to dimensions supplied to Contractor. Door frame shall contain a flush- mounted switch and pilot light on the outside of the frame and vaporproof lights on the interior of the frame.Freezer frame shall have a thermo -disc control, UL approved heater wire around the perimeter of the door frame to prevent door from freezing shut. A temperature alarm shall be provided. Door shall be same thickness as walls. Door hardware shall be chrome plated. Cooler- freezer shall be a nominal 8 feet high. Purchased and installed by Contractor) Page 2 of 3 KITCHEN EQUIPMENT LIST BOYNTON BEACH CHILD CABS CRITER ITEM MAKE SUTAL NUMER 10. Reach -in Freezer, Furnished by others Not found electric (existed, electric hook -up by Contractor) 11. Milk Cabinets, Furnished by others Not found electric (existed, electric hook -up by Contractor) Not found 12. Pick up table Custom Built by Contractor Not found (same construction as clean and soiled dish table, except no backsplash. 84" X 30" X 30" h.) 13. Refrigerator, Furnished by others Not found electric (existed, electric hook -up by Contractor) 14. Kettle, 20 gal, Groen 40873 -5 self contained AFL 1 -20 steam source, LP gas • (purchased and installed by Contractor) 15. Mixer, Hobart 11- 416 -527 floor mounted 600T electric (purchased and installed by Contractor) 16. Slicer, electric Furnished by others A8920071 Model 412 (existed, electric hook -up by Contractor) 17. Mixer, electric Furnished by others 1868966 Hobart A -200 (existed, electric hook-up by Coptractor) 18. Misc. Shelving Custom Built by Contractor Not found for dry storage and cooler /freezer (Designed as heavy duty shelves press - formed from a single sheet of 16 gauge stainless steel in cooler freezer. Aluminum in dry storage. Set screw shall be provided to lock shelves at desired height on posts. Entire assembly shall be stationary) 19. Two preparation tables, Custom Built by Contractor Not found stainless steel (Custom designed to dimensions supplied to Contractor) 20. Fire Suppression Ansul 116260 System R -102 (Purchased and installed by Contractor. Restaurant fire suppressant system with ansulex liquid fire suppressant agent. Must be provided with stainless steel tank, three gal cap to meet required pressure test. Tank shall include an adaptor /tube assembly, provide discharge nozzles, regulated release mechanism, link detection system, remote manual pull station, mechanical gas line shut -off valve, electric gas line shut -off valve, electric snap- action switch, and pressure switch, pneumatically operated to shut off of electric power to appliances) EXHIBIT "A" Page 3 of 3 KITCHEN EQUIPMENT LIST BOYNTON BEACH CHILD CARE CENTER ITEM MARE SERIAL NUMBER 21. Carts (3) Furnished by others Not found 22. Tray Rack Furnished by others Not found 23. Misc vessels, Furnished by others Not found pots & pans In essence, all of the items in the kitchen area of the Boynton Beach Child Care Center is the property of Palm Beach County and should be labeled as such. • i C 1 I • O T • B O Y N O N BEACH «- : -_.._: - -' 120 E. Boynton Beach Blvd. —�- ! -c.• P. 0. Box 310 't '��`� Boynton Beach, Florida 33425 -0310 _ °• rte'= Y! (305) 734 -8111 RECEIVED SEP .2 71489 September 18, 1989 HEAD START AND CHILDREN SERVICES Mr. Eugene Nanselle Palm Beach County Community Services 810 Datura Street West Palm Beach, Florida 33402 Dear Mr. Manselle, Attached are copies of Change Order #1 for the kitchen equipment at the Boynton Beach Child Care Center. Also included are copies of the equipment specifications. The Change Order is for the supplying and installation of the equipment only. All the costs of the utility hookups were included in the base contract. For your use in reimbursing the City the $51,250.00 as approved and discussed. ill DeBeck Project Manager Everald Badchkam to make payment 7.r it cc: George Hunt SEP 2 6 iqR9 • ........ nn /1• • CHANGE ORDER " " "`� ❑ ARt =1111 f C1 ❑ /1111 VOCUMINT C701 CONTRA( 1OR ❑ IRO) ❑ ()1IIUR [� r('( )1E0 Boynton Beach Chi Id Care Center CIIANC,E ORDER NUMBER One in.-me addrescl 909 Northeast Third Street Boynton Beach, FL _ INITIATION DAZE• January 6. 1989 1() 'Contractor) ARCHITECT'S PROTECT NO 8713 Lear Group, Inc. CONTRACT FOR: Construction 3930 RCA Boulevard Palm Beach Gardens, Ft. 33410 • CONTRACT DATE- 09/26/88 You are directed to make the following changes in this Contract: Furnish And install Kitchen Equipment as reouested by the Owner in correspondence dated November, 1988. • J y t .. \..t •.,Ill nnl.l ..4 tl In h„Ih the 1 rat nrr .uat An hetet 1 hurt• n1 11.1• ( .n :It.0 lur u»Ii .,t• • hI% slIgrr.•nn h• Ithtttlt. ,n. .un a,Ilu•1•n. nl '^ ,h ('.nl.lcl C .r ( .ytr• I ht• r•••I;1n.11 (( un11.1c I Sum) •(Y XKX'kl(A'f:Itk'Xxtr.>tI<Xk!<K wlc $ 652,558.00 !•1t•t t Ii.rngc Its InICt ■Iv authiu.zed Change Orckr% .. .... $ 0.00 the +t un(tat I Sun (g.y,tyNlayttnxxxxotx)1x40 prior Io this Change Orcler ccac ...... $ 652,558.00 the (( sun1t Ot kiXK•XXX)A) X'itkXXEKNN) will he (increased) 04Ku XXx$XK X!'L)::0111 by lhtc Change Order S 51,250.00 The nett (Contract Sum) rf(xx :,cykomxxxYri-gltk 1nr hiding this Change Order will be S 703,808.00 the Contract lime t,,II he (1:X1 :xx.xKXII&XK%XII) (unchanged) by The Date of Substantial Complchun as of the dale of this Change Order therefore is Aulhort,ed• Smith Obst Associates. AIA Lear Group, Inc. City of Boynton Bcach A ?Vt t( ? . Congress Ave Ste. 2 -C Boulevard — (1ibtrEast 9o Ech. nadirs, . Aritl,eac W. Palm Bch., FL 33406 Palm Bch. Gdns, FL 33 Boynton Bch. FL -- — — It` — - -- - -- ny f . n� - - -- - -- - - f) 1t DATE • • , / / DM( - 7- 9 A1, rim Vc'1•4T (,'1I • ( • r •At)Il: • A11:I1 )•r•• Ili. • ". • NI N" 1 r•f. r-t-1t __ to- rev. 4/7/88 11401/01 SECTION 11401 - FOOD SERVICE EQUIPMENT PART 1 - GENERAL 1.01 RELATED DOCUMENTS , The general provisions of the contract, including General Conditions (AIA Doc. A201), Special Conditions, General Requirements, and Supplementary Conditions of the Contract apply to the work specified in this section. 1.02 DESCRIPTION Supply and install all food service equipment specified and /or shown on the drawings. All electrical, plumbing and HVAC, including range hood and duct work, shall be the general contractor's responsibility. Included are delivery, uncrating, installation, setting equipment in place, coordination with other trades, start up, service, and one year guaranty /warranty, except as stated otherwise herein. • 1.03 QUALITY ASSURANCE Comply with 1 the following standards as applicable to manufacture, fabrication and installation of the work of this section: NSF Standards: Comply with National Sanitation Foundation standards and criteria. Provide NSF "Seal of Approval" on each item. UL Standards: For electrical items provide either UL label products or, where no labeling service is available, "recognized markings" to indicate listing in the UL "Recognized Component Index ". ANSI Standards: For gas burning equipment, comply with ANSI Z21- Series standards and provide labels indicating name of testing agency. Comply with ANSI 857.1 for compressed gas cylinder connections, and with applicable standards of the Compressed Gas Association for . compressed gas piping. Comply with ANSI 40.4 and A40.6 for water connection air gaps and vacuum breakers. . American Gas Association Standards . Certifications: All motorized and electrically operated equipment shall be approved by the Board of Fire Underwriters. If required to do so, this Contractor shall submit suitable documents to A/E for submission and review to Agencies having jurisdiction. Other Standards: Comply with NFPA No. 96 including Appendix A, for exhaust system; ASME Boiler Code and ASME inspection stamp and National Board Registration: National Electric Code; Vol.3, as related. 1, Supplier of this Equipment shall be established in this type of work in Southeast Florida for a minimum of five years. • • 11401/02 _ Equipment, material and work shall conform to all state and federal laws, municipal ordinances and regulations, etc. having jurisdiction, including HRS, NFBU, State Accident Commissions Safety Orders, and City of Boynton Beach Building Department. 1.04 SANITATION Unless otherwise shown or specified, fabricate equipment abutting wall and columns and position with a clearance of 3 inches minimum between finished walls and equipment, with the exception of cabinets which shall be closely fastened to the walls with resulting crevices sealed with suitable mental bands or moldings, and cooking equipment, which shall have clearances according to code. 1.05 SUBMITTALS . Shop Drawings: Submit shop drawings in quadruplicate, showing layouts, elevations, sections and details of custom fabricated work, metal gauge, connections. PART 2 - EQUIPMENT . 1. Range Re-use and re- install existing range. Convert to natural gas. 2. Oven Re -use and re- install existing convection oven. Convert to nat. gas. 3. Hood ; cover open flame equipment, extending over sides and front a minimum of: 6 ". Comply with NFPA Std. 96. Hood and exposed exhaust ductwork shall be constructed from stainless steel sheets with liquid -tight continuou3 external welds for all seams and joints. Seams shall be ground smooth. Electrical conduit shall be run concealed in area beyond the filters. Light fixtures shall be explosion -roof. Ductwork shall be constructed of 60 ga. metal or heavier. Install filters at an angle not less than 45 degrees, quantity as recommended by the manufacturer. Hood shall have a removable grease tray installed just under the filters. Tray shall be removable in sections, for ease of cleaning. Provide residue trap with cleanout at base of riser. - Shop drawings must be complete, detailed, and accurately described for submission to the Bldg. Official and other authorities having jurisdiction, in full compliance with all codes. Shop drawings shall be accurate and of quality to be approved on first submission. 4. Dishwasher Hobart C -44 27 "x44" electric 5. Soiled dish table: st.steel, custom built, 14- ga, work surfaces formed and welded with N seamless construction, using welding rods matching sheet metal, grinding and polishing to a satin finish. Reinforce work surfaces 30" o.c. both ways with galv.or stainless concealed structural members. Reinforce edges. Major area shall be 96 "x 24 ", with continuous 6" integral backsplash, welded closed, and diagonal back splash and return to dishwasher. • • 11401/03 Sound . deaden underside of work surfaces,holding coating back 3" from sanitary edges whih are open for cleaning. Structural framing shall be 1" pipe size, with mitered and welded joints and gusset plates, ground smooth. Conform to NSP standards. Provide enclosure of service lines, operating components, mechanical and electrical devices. Provide opening for waste disposal and pre -rinse unit, and install same. 6. Pre -rinse and garbage disposals Waste King Universal HDG -1 or HDG -3, with 19 spray rinse, syphon breaker, vol -temp assembly, globe valve, all tubing and piping; 12" bowl and accessories, group APS. 7. Clean dish table: custom built, stainless steel, 16 ga, work surfaces formed and welded with seamless construction, using welding rods matching sheet metal, grinding ;and polishing to a satin finish. Reinforce work surfaces 30" o.c. both ways with galvanized or st. concealed structural members. Reinforce edges. Major area shall --' - -be 96 "x 24 ", with continuous 6" integral backsplash, welded closed, and diagonal bade splash and return to dishwasher. • Provide continuous undershelf to be fastened to suport members. Sound deaden underside of work surfaces,holding coating back 3" from sanitary edges which are open for cleaning. Structural framing shall be 1" pipe size, with mitered and welded joints and gusset plates, ground smooth. Conform to NSP standards. • Provide enclosure of service lines, operating components, mechanical and electrical devices. 8. Shelves above clean dish table: stainless steel, 18 gauge, same construction as for tables. Design shelves and install to support 40 lbs. per sq. ft. loading plus 100% impact loading. 9 . 3 compartment sink & drainboards: not specified in this section; included in Division 15. 10. Walk -in cooler - freezer: built to dimensions shown on the drawings. Insulation for- copitr -- shall be rigid expanded polystyrene, ensite 1 -1 1/2 lbs. /sq.ft. with K factor of .22 at 40 degrees and vapor transmission rate of less than 1.7 perms. Panels shall be of thickness to meet these requirements, with a minimum thickness of 4 ". Freezer sections shall be rigid urethane, density 1.8 lbs. /sq.ft. with a K factor of .15 at 40 degrees and a vapor transmission rate of less than .2 perms. Panels shall be of thicknss to meet the above requirements, but in no cases Tess than 4" thick. Facings shall be aluminum mill finish, 24 gauge, stucco embossed for exterior, with • an interior (cooler /freezer sides) of stainless steel, 24 gaue, type 304, no.3 finish, t paper protected. Floors shall be quarry tile finish and shall be flush with kitchen floor. ( 1 e 1 Connectors shall be plastic encased, eccentric, panel connecting speed locks shall be able to stand 1,400 Ib. tension load and shall draw panels toether with sufficient pressure t9 establsh an airtight seal. i • 11401/04 • Door frame shall contain a flush- mounted switch and pilot light on the outside of - the frame and vaporproof lights on the interior of the frames. Freezer frame shall have a thermo -disc control, UL approved heater wire around the perimeter of the door frame to prevent door from freezing shut. Provide a temperature alarm system. • Doors shall have gaskets of replaceable closed cell rubber not less than 1 1/2" wide. door shall be same thickness as walls. Door hardware shall be chrome plated. Cooler /freezer shall be a nominal 8 feet high. 11. Reach -in Freezers Re-use existing unit. 12. Milk cabinet: furnished by others. • 14. Pidc up table: same construction as clean and soiled dish tables, except no backsplash. 84" x 36" x.30" h. 15. Hand lavatory: see plumbing, division 15. • 16. Fire Suppression System: Ansul R -102 Restaurant Fire suppressant System, with Ansulex Liquid Fire Suppressant agent, (potassium carbonate, potassium acetate -based formula designed for lame knockdown and securement of grease - related fires). Proxide stainless steel storage tank, three gal. capacity to meet required pressure testi. Tank shall include an adaptor /tube assembly. Provide a welded steel bracket • for mounting. proide discharge nozzles, regulated release mechanism, and a fusible • link detection system, remote manual pull station, mechanical gas line shut -off valve, electric gasline shut off valve, electric snap- action switch, and pressure switch, pneumatically operated to shut of electrical power to appliances. 1 17. 2 compartment sink & drainboards: not specified in this section; included in Division 15. 18. Refrigerator: re-use existing refrigerator. 19. Kettle: Groen AH/1 20 gal. capacity, self contained steam source, for LPG, 2/3 20. Mixer: Hobart H -600, floor mounted. 21.& 22. prep tables, stainless steel. 23. Misc. shelving for dry storage and cooler /freezer: heavy -duty with shelves press- formed from a single sheet of 16 gauge stainless steel in cooler /freezer, aluminum in dry storage. shelving shall be slotted, with slots 1 3/4" o.c., drawn down along entire perimeter at 45 degrees from surface. Each shelf corner shall be fitted with a bradcet to accommodate the post. Shelf shall be formed down and flanges up, into • the bracket to completely encase and conceal the bracket within the shelf. No II crevice, joint or opening shall exit between bracket and shelf top surface and flanges. A set screw shall be provided in the bracket to lock the shelf at the desired height on the post. Uprights: 1 5/16" o.d. 16 gauge stainless steel tuing. Provide top cap and flange for each post. Height of assembly shall be nominally 57 -3 ". Assembly shall be stationary. • 1 #• 24 Work table • no backsplash 11401/05 25 Work table 26 Dishwasher exhaust hood PART 3 - EXECUTION 3.01 INSPECTION AND PREPARATION • Rough -In Work: Installed shall examine the rough -in mechanical and electrical services by others, and floors, walls, and ceilings by others; and conditions under which the work is to be done. Verify dimensions of the services and substrates before fabricating. Notify contractor in writing of unsatisfactory locations and dimensions of other work, and of unsatisfactory conditions for the proper installation of food service equipment. Do not proceed with the fabrication and installation until• unsatisfactory dimensions and conditions have been corrected in a manner acceptable to the Installer. ' Installer of walk -in refrigerated storage units must examine the ,surfaces of the substrate to receiv the work, and the conditions under which the work is to be performed. Notify the Contractor In writing of unsatisfactory conditions. Do not proceed with the work until unsatisfactory conditions have been corrected in a manner acceptable to the Installer. Verify that depressed slab is satisfactory. - I 3.02 INSTALLATION General Comply with manufacturer's instructions. I Seal points and openings, including penetrations for piping or electrical .wiring, in the outside and inside faces of walk -in refrigerated storage construction. At line of support on other floor construction (outside and inside) seal with a formed cove of sealant or other coved trim member, to comply with NSF standards. • I Install closure panels and strips where indicated and where installed unit of work results in a residual space which is not of sufficient size to be cleaned or maintained in accordance with I NSF standards. Seal joints and provide formed cove of sealant or other coved trim member, to comply with NSF standards. 1 Evaporator installation: Comply with NSF standards for the positioning of evaporator units in walk -in refrigerated storage units (access for cleaning). - Adtust and clean: Do not use any abrasives. Take care not to displace existing wiring or 1 piping. • Ill END OF SECTION II ' 1 II •