Wendy's @ Riverwalk Plaza DEVELOPMENT ORDER OF THE CITY COMMISSION OF THE
CITY OF BOYNTON BEACH, FLORIDA
PROJECT NAME: Wendy's @ Riverwalk Plaza
APPLICANT'S AGENT: Land Design South
APPLICANT'S ADDRESS: 1280 North Congress Avenue, Suite 215
West Palm Beach, FL 33409
DATE OF HEARING RATIFICATION BEFORE CITY COMMISSION: April 16, 2002
TYPE OF RELIEF SOUGHT: Conditional Use / Major Site Plan Modification
LOCATION OF PROPERTY: Northwest corner of the Riverwalk Shopping Center located on the south
side of Woolbright Road, east of U.S. 1 and west of the Intracoastal
Waterway.
SEE EXHIBIT "B" ATTACHED HERETO.
DRAWING(S):
THIS MATTER came before the City Commission of the City of Boynton Beach, Florida
appearing on the Consent Agenda on the date above. The City Commission hereby adopts the findings
and recommendation of the Planning and Development Board, which Board found as follows:
OR
X THIS MATTER came on to be heard before the City Commission of the City of Boynton
Beach, Florida on the date of hearing stated above. The City Commission having considered the relief
sought by the applicant and heard testimony from the applicant, members of city administrative staff and
the public finds as follows:
Application for the relief sought was made by the Applicant in a manner consistent with the
requirements of the City's Land Development Regulations.
The Applic.ant
~ HAS
HAS NOT
established by substantial competent evidence a basis for the relief requested.
The conditions for development requested by the Applicant, administrative staff, or
suggested by the public and supported by substantial competent evidence are as set forth
on Exhibit "C" with notation "Included".
The A.pp!ic.,,ant s application for relief is hereby
_Z~,_ GRANTED subject to the conditions referenced in paragraph 3 hereof.
DENIED
5. This Order shall take effect immediately upon issuance by the City Clerk.
All further development on the property shall be made in accordance with [he terms and
conditions of this order.
7. Other
DATED:
\\CH\MAIN\SH RDATA\Planning\SHARED\WP\PROJ ECTS\Wendy's @'
LOCATION MAP
Wendy's at Riverwalk Plaza
EXHIBIT "A"
PU
PU
EXHIBIT "B"
t
-4~_ _ _ _ _./ i/
I
it
i /I/
i / 1
/
RIVERWALK SHOPPING PLAZA
WENDY'S OUTPARCEL
PRePAReD FOR PJV~=IWAI,J~ P~AZA ~IOINT V~TMRE
CiTY OF BOYN'rON BE, ROt-I, FLORIDA
DESIGN
SOUTH
EXHI. BIT "B"
~. iI
~. I
ltl
/
/
/
/~ /
/ !
! /
\\Serveri\pro)ects\WenOys\Boyn~on - Riverwa]k\A2.dwg Fri Mar 22 I~:05:57 2002
EXHIBIT "B"
Ill
:' ilill
II ]:i ?:
ll[~i~ Ii I I~[
Il
Ill Ill Ill"
I:tJFUll~ l_ i , · I l
i ...... I1 !
~ t
r rrr~
/,
/ /
E~HIBI'
'/
11 B II
J-J~Jl I H IJUUJJ[ILLU~ItNATION PLAN
'i
!t B !I
EXHIBIT "C"
Conditions of Approval
Project name: Wendy's ~ Riverwalk Plaza
File number: COUS 02-001
Reference: gna review plans identified as Conditional Use/Site Plan with a March 26, 2002 Planning & Zoning
date stamp marking.
DEPARTMENTS INCLUDE REJECT
PUBLIC WORKS- General
Comments: None X
PUBLIC WORKS- Traffic
Comments: None X
UTILITIES
Comments:
1. All utility easements shall be shown on the rectified site plan and X
landscaping drawings so that we may determine which trees may interfere
with utilities. In general, palm trees wilt be the only tree species allowed
within utility easements. Canopy trees may be planted outside of the
easement so that roots and branches will not impact those utilities within the
easement in the foreseeable future. The LDR, Chapter 7.5, Article I,
Section 18.1 gives public utilities the authority to remove any trees that
interfere with utility services, either in utility easements or public rights-of-
way.
2. Palm Beach County Health Department permits will be required for tee X
water and Sewer systems serving this project (CODE, Section 26-12).
3. Fire flow calculations will be required demonstrating the City Code X
requirement of 1,500 g.p.m. (LDR, Chapter 6, Article IV, Section 16), or
the requirement imposed by insurance underwriters, whichever is greater
(CODE, Section 26-16(a)).
FIRE
Comments:
4. Design documents where underground water mains.and hydrants are to be X
provided, must demonstrate that they will be installed, completed, and in
service prior to construction work per the Florida Fire Prevention Code,
(2000) Section 29-2.3.2.
POLICE
Conditions of Approval
2
DEPARTMENTS INCLUDE t REJECT
Comments: None X
ENGINEERING DIVISION
Comments:
5. Sho~v all existing utilities on site characteristics map (survey) and site X
development plan (LDR, Chapter 4, Section A.3). Master Site Plan and
survey do not agree.
6. On the lighting plan, specify that the light poles shall withstand a 110 MPH X
wind load.
BUILDING DIVISION
Comments:
7. Verify that the proposed elevation is in compliance with regulations of'the X
code by adding specifications to the site data that address the following issues
[Section3107.1.2, Chapter 31 of the Boynton Beach amendments to the 1997
edition of the Standard Building Code]:
a) The design professional-of-record for the project shall add the following
text to the site data. "The proposed finished floor elevation
NGVD is above the highest 100-year base flood elevation applicable to
the building site, as determined by the South Florida Water Management
District's surface water management construction development
regulations.,,
b) From the FIRM map, identify in the site data the title of the flood zone
that the building is located within. Where applicable, specify the base
flood elevation. If there is no base flood elevation, indicate that on the
plans.
c) Identify the floor elevation that the design professional has established for
the building within the footpr/nt of the building that is shown on the
drawings titled site plan, floor plan and paving/drainage (civil plans).
8. Place a note on the elevation vie~v dra~vings indicating that the wall openings X
and wall construction comply with Table 600 of the 2001 edition of the
Federal Building Code.
9. At time. of perrrdt review, submit signed and sealed working drawings of the X
proposed construction.
10. At the time of permit review, submit for review an addressing plan for the X
Project.
Conditions of Approval
3
DEPARTMENTS
PARKS AND RECREATION
Comments:
11. Submit detailed irrigation plans for right-of-way landscape and irrigation
improvements during the construction document permitting stage, for review
and approval by Parks Department and Public Works Department staff.
Include on the plan location of any existing irrigation in the right-of-way.
FORESTER/ENVIRONMENTALIST
iNCLUDE
X
Comments: None X
PLANNiNG AND ZONING
Comments:
12. Provide a detail of the outdoor lighting structure, including the dimensions,
color, and material. Site lighting to be consistent with shopping center.
13.
14.
15.
16.
Site lighting shall not be of an intensity that produces glare on adjacent
properties (Chapter 9, Section 10.C). Staffrecommends that the proposed
freestanding outdoor lighting fixtures and illumination levels shall be
compatible with the existing shopping center.
On the site plan, add to the note regarding deliveries the hours of operation
for the restaurant.
Include a color rendering of all elevations prior to the Community
Redevelopment Board meeting (Chapter 4, Section 7.D.2.).
On the landscape plan plant schedule, indicate the specifications for the
double-trunk Solitaire Palm (PE) trees.
All parking tot areas shall be screened with landscaping from public rights-of
way. If the construction of the restaurant causes a ground elevation change,
rendering the existing landscape material along Woolbri ght Road to become
inadequate as it relates to the intent of the code, then said landscape material
shall be enhanced subject to the satisfaction of the City landscape inspector.
All above ground mechanical equipment such as exterior utility boxes,
meters, and transformers, shall be visually screened (Chapter 9, Section
10.C.4.). Equipment placed on the walls of the building shall be painted to
match the building color.
17.
18.
X
X
X
X
X
X
X
REJECT
Conditions of Approval
4
DEPARTMENTS INCLUDE REJECT
19. Re-label the elevation drawing to show that 67.5 feet is the maximum allowed X ·
for all wall signs. .,:.
20. Should the building size or frontage slightly change during the permitting X
process, alt wall signs on the building (north and west elevation) must comply
with Chapter 21, Article IV, Section 3.C.
21. On the elevations, correctly label each faCade as north, south, east or west. X
22. The current site plan.does not show proposed awnings to be placed over the X
drive-through windows. Please show these on the plans submitted for
building permit review. Awnings must comply with all applicable code
requirements.
23. Staff recommends that the audio component and menu board for the drive X
through facility project its sound to the interior of the site and be of a level as
to not create a disturbance to the residential neighborhood to the north.
24. Pursuant to Chapter 2-Z0ning, Section 11.2 Conditional Uses, a time limit is X
to be set within which the proposed project is to be developed. Staff
recommends that a period of one (1) year be allowed to initiate this project.
25. The project must receive approval for traffic concurrency from Palm Beach X
County Traffic Engineering prior to building permit issuance.
ADDITIONAL COMMUNITY REDEVELOPMENT BOARD CONDITIONS
Comments:
26. All free standing outdoor lighting fixtures/poles shall meet current wind load I. X
standards.
27. Rooftop equipment screening to be no lower than the highest piece of roof X
top equipment, including all mechanical and ventilation items.
28. Perimeter or parking lot hedges shall be maintained no less than 30 inches. X
29. The City Forester/Environmentalist shall examine the four (4) trees to be X
preserved along the north property line. If found to be in proof condition,
they shall be replaced with live Oak trees.
Conditions of Approval
$
DEPARTMENTS INCLUDE REJECT
30. Add 2 trees along west side of"leased parcel", each evenly spaced on both sides of X
proposed trees.
ADDITIONAL CITY COMMISSION CONDITIONS
Comments:
31. To be determined.
S:\Planning\SHARED\WP\PROJECTS\Wendy's @ Riverwalk\COUS\Condition of Approval 2 page revised 2002 form.doc