Loading...
16-1735'EXISTING PASSIVE LOUVER VENT 4'X 4' LLii��i���ii��.�i��,�:�siir�ii���►r� LEUAL DESCRIPTION LOT 6, BLOCK 2, CEDAR RIDGE, A P.U.D. & HIGH RIDGE COMMERCE PARK, A P.I.D., ACCORDING TO THE PLAT THEREOF ON FILE IN THE OFFICE OF THE CLERK OF THE COURT IN AND FOR PALM BEACH COUNTY, FLORIDA, RECORDED IN PLAT BOOK 46, PAGES 58 THROUGH 61, CONTAINING 1.099 ACRES MORE OR LESS. EXIS I IIVG t'A551 V t LOUVER VENT 4'X 4' LOUVER VENT 4'X 4' EAST SIDE EXISTING FA5slVt LOUVER VENT 4'X 4 CA10 1 114- 1---- LOUVER VENT 4'X 4' P&M x EXISTING PASSIVE LOUVER VENT 4'X 4' . _t EXISTING PASSIVE LOUVER VENT 4'X 4' EXISTING WALL EXHAUST FAN cd to EXISTING WALL EXHAUST FAN EXISTING INTERIOR IMPROVEMENT NOTES: PREVIOUSLY APPROVED INTERIOR OFFICE, WALLS AND MEZZANINE NOT SHOWN. ELECTRIC NOTES: ELECTRICAL SERVICE PANELS A AND BAND CORRESPONDING CIRCUITS ARE ALL ISOLATED TO SOUTH SIDE OF PROPOSED WALL. NO A AND B SERVICE PANEL CIRCUITS ARE LOCATED ON NORTH SIDE OF PROPOSED WALL. ELECTRICAL SERVICE PANELS C AND D AND CORRESPONDING CIRCUITS ARE ALL ISOLATED TO NORTH SIDE OF PROPOSED WALL. NO C AND D SERVICE PANEL CIRCUITS ARE LOCATED ON SOUTH SIDE OF PROPOSED WALL. FIRE SPRINKLER NOTES: ENTIRE BUILDING INCLUDING NORTH AND SOUTH SPACE IS PROTECTED BY EXISTING PREVIOUSLY APPROVED FIRE SPRINKLER SYSTEM 141 COMMERCE RD - NORTH SIDE 141 COMMERCE RCS - SOUTH SIDE PRIMARY NATURAL VENTILATION — CALCULATIONS PRIMARY NATURAL VENTILATION — CALCULATIONS REQUIREMENTS: REQUIREMENTS: MINIMUM OPERABLE AREA TO TH ILATION IS ALLOWED AS LONG AS THE MINIMUM OPERABLE AREA TO THE PER FBG MECHANICAL CODE SECTION 402.2, NATURAL VENTILATION IS ALLOWED AS LONG AS THE PER FBC MECHANICAL CODE SECTION 402.2, NATURAL VENT OUTDOORS IS 4% OF THE FLOOR AREA BEING VENTILATED. OUTDOORS IS 4% OF THE FLOOR AREA BEING VENTILATED. PROVIDED:PROVIDED: — OVERHEAD DOORS. THERE ARE TWO 42)12'-0" WIDE x 16'-0" HIGH MINIMUM OPERABLE AREA ACHIEVED THROUGH THE EXISTING OVERHEAD DOORS . THERE ARE TWO (2)12'-0" WIDE x 16'-0" HIGH MINIMUM OPERABLE AREAACHIEVED THROUGH THE EXISTINGDOORS AND TWO (2) 10'-0" WIDE x 12'-0" HIGH DOOR. TOTAL OVERHEAD DOOR OPENING AREA — 624 SQUARE FEET. DOORS AND TWO (2) 10'-0" WIDE x 12'-0" HIGH DOOR. TOTAL OVERHEAD DOOR OPENING AREA = 624 SQUARE FEET VENTILATED AREA =158' x 98' =15,484 SQUARE FEET VENTILATED AREA= 78' x 98'+ 48'x 59' =10,476 SQUARE FEET WHICH IS EQUAL TO 4 /o MINIMUM REQUIREMENT A 624 SF / VENTILATED AREA (10,476 SF) = 5.9%, WHICH IS GREATER THAN 4% MINIMUM REQUIREMENT. TOTAL OPENING AREA (624 SF) / VENTILATED AREA (15,484 SF) = 4%, ° TOTAL OPENING ARE 4 ) REDUNDENT MECHANICAL VENTILATION - CALCULATION: REDUNDENT MECHANICAL VENTILATION - CALCULATION: REQUIREMENTS: REQUIRED OUTDOOR VENTILATION — 1.50 CFM PER SQUARE FOOT PER FBC MECHANICAL CODE TABLE 403.3, REQUIRED OUTDOOR VENTILATION =1.50 CFM PER SQUARE FOOT. REQUIREMENTS: PER FBC MECHANICAL CODE TABLE 403.3, — EXISTING: EXISTING: VENTILATED AREA =15,484 SQUARE FEET, VENTILATED AREA= 10,476 SQUARE FEET 15,484 SQUARE FEET X 1.5 CFM PER SQUARE FOOT = 23,226 CFM TOTAL MINIMUM REQUIREMENT. 10,476 SQUARE FEET X 1.5 CFM PER SQUARE FOOT =15,714 CFM TOTAL MINIMUM REQUIREMENT. ONE (1) EXISTING FAN YIELDS 19,656 CFM. ONE (1) EXISTING FAN YIELDS 19,656 CFM, WHICH IS GREATER THAN 15,714, MINIMUM REQUIREMENT. THE FAN HALL BE USED AT ANY GIVEN TIME. RE ARE FIDE (5) EXISTING EXHAUST FANS, BUT ONLY TWO (2) FAN SHALL BE USED AT ANY GIVEN TIME. 2 x 19,656 = 39,312 CF - THERE ARE TWO (2) EXISTING FANS, BUT ONLY ONE (1) S M,.WHICH IS GREATER THAN 23,226 CFM, MINIMUM REQUIREMENT. ' THERE ARE THREE (3) 4'X 4' INTAKE LOUVERS IN THIS VENTILATED AREA. THERE ARE FOUR 44} 4' X 4' INTAKE LOUVERS IN THIS VENTILATED AREA. THESE LOUVERS YIELD .55 FREE AREA, WHICH EQUALS 8.8 SF PER LOUVER x3 = 26.4 TOTAL FREE AREA. AREA. 26.4 SF FREE AREA X 1,200 FPM = 31,680 CFM THESE LOUVERS YIELD .55 FREE AREA, WHICH EQUALS 8.8 SF PER LOUVER x4 = 35.2 TOTAL FREE AREA. LOUVERS YIELD 1,200 FPM IN FREE LOUVERS YIELD 1,200 FPM IN FREE AREA. 35.2 SF FREE AREA X 1,200 FPM = 42,240 CFM 31,680 CFM IS GREATER THAN 19,656 CFM (ONE FAN CAPACITY). 42,240 CFM IS GREATER THAN 39,312 CFM (TWOFAN CAPACITY). HIGH RIDGE HOLDINGS LLC. 141 COMMERCE RD. BOYNTON BEACH, FL 33426 09 m U ENGINEERING .j LLj 2213 22nd LANE C- PALM BEACH GARDENS, Z FL 33418-3568 Z OFC: (561) 625-6455 J FAX: (888) 788-2515 W EMAIL terry@telunnpe.com � FL REG #26119 SEAL STATIE 0 Apr 1,52016 8.36:14 OS:, I� ELME IIn D BY DATE.. I Structural bini @ 'ek4�u' DmeY Rev. 4-12-16 DATE PG. 1 OF 1