12-34221
2
3
4
5
6
Uy:
2-2 x 12
30'_0„
FLORIDA PLUMBING CODE 2010
Circuit protection is required to comply with NEC 240.4.
15'-0"
F
EXIST SCREEN PORCH
EXIST SGD
EXISTING kA
C.M.U.WALL
EXIST RAFTERS THIS 4 FT.PORTION OF FLAT
DAMAGED BY WATER DECK PLYWOOD TO BE
INTRUSION REPLACED DUE TO WATER
a SEE ENG. LETTER I AS NEEDED PLACE INSUL.
ATTACHED FOR FIX.
X
CDW - --- ------ -- -
I I
KITCHEN
BRKST NO CHANGE FROM ORIGINAL LAYOUT AREA OF WATER DAMAGE TO CEILING
NEW CABINETS AND APPLIANCES
�~ O0 REF
0 0 EXIST DINING ROOM
-"`-""" " - - NO WORK THIS AREA
AHU ABOVE
EWH BELOW
U
AREA OF WATER DAMAGE TO CEILING
GARAGE
NEW CONC.-----------------------,
SLAB FOR
AC COMP.
I I
I I
I 1
I I
0/H DOOR EXISTING
I l
I I
I I
I I
I I
I I
I I
I I
I I
12'-0"
All Electrical work shall comply with the current
adopted edition of the National Electical Code
EXIST LIVING ROOM
NO WORK THIS AREA
. Ab
/SSG%-
r E-VIEWJ`L; GY
I EI cal I97, 1)._ 1 1/11- 16 - > z I
licai (%'
EXISTING FLOOR PLAN_
1/4'v=1 '-0"
EXIST MASTER BEDROOM
NO WORK THIS AREA
7
1 0 �- AREA OF WATER DAMAGE TO CEILING
SO
-- ,�
SID B
I , I
I
I I
I I
I I
I I
II
I
I .
40/y,
EXIST BEDROOM 2
NO WORK THIS AREA
DESIGN CRITERIA:
FLORIDA BUILDING CODE 2010 RESIDENTIAL
E STING BLDG LEVEL I
All electrical equipment shall be installed according to the
I Other
FLORIDA BUILDING CODE 2010 Al
manufacture specifications and the NEC.
Uy:
2-2 x 12
HEADERS
FLORIDA PLUMBING CODE 2010
Circuit protection is required to comply with NEC 240.4.
a SseC
FLORIDA MECHANICAL CODE 2010
Equipment shall be listed and labeled.I
Conductor sizes shall comply with NEC 310.15.
��� ,; „ �, �,�;
with all
NEC 2008
The contractor shall verify the service and panel
have the capacity to serve the new load per NEC 220.
The total load shall not exceed the rating of the branch
°tin�U�FK
circuit per NEC 220.18.
AIn:r F.= I;;~TPi�:Alw SHALL CO=v9Fl_V �tl�s
THE 200S1NATOiNAL
ELECTRICAL CODE
1 2
3
41 _
5. 6
9 I 10 I 11 I 12
LEGE: N DN O
A -EXISTING OPENING TO BE INFILLED. SEE DETAIL "A" THIS SHEET
B -EXISTING KITCHEN CABINETS REMOVED AND REPLACE WITH NEW
C -WATER HEATER BELOW AHU TO BE REPLACED
D -EXISTING BATH VANITY AND FIXTURES REPLACED WITH NEW EXCEPT TUB. EXACT LOCATION
REMOVE EXIST HEAT LAMP FIXTURE AND REPLACE WITH CEILNG LIGHT FIXTURE
E -EXISTING BATH VANITY AND FIXTUES REPLACED WITH NEW. EXACT LOCATION
F -ALL SCREENING TO BE REPLACED
G -REMOVE ALL COVE LIGHTING AND REPLACE WITH CEILING FIXTURE
EXISTING 8" FRAME PARTITION
V1�IIIIIIr/ 11�Ill11UL1111JI111�111�1 NEW 8" FRAME INFIL WALL
C-- EXIST 4'FRAME WALLS
GENERAL NOT
NO CHANGE IN LIVING AREA
ALL DOORS AND WINDOWS EXISTING
GENERAL REPAIRS TO WATER DAMAGED WALLS AND CEILING AS NOTED ON PLAN
*EXISTING ROOF HAS BEEN SEAL COATED TO PREVENT LEAKS
RE -INSULATE ALL CEILING AREAS WHICH CONTAINED WATER DAMAGE WITH MIN R19 INSUL..
ELECTRICAL:
ADD ONE ADDITIONAL GENAECEPT. EACH SIDE OF INFILL WALL AS NOTED
TIE INTO EXIST GEN.LIGHTING CKT. W-#14 WIRE
REPAIR -REPLACE ANY BROKEN -DEFECTIVE OUTLETS
REPLACE DEFECTIVE SMOKE DETECTORS
NO OTHER CHANGES TO EXISTING ELECTRICAL
PLUMBING:
ALL LAVATORIES, TOILETS, FAUCETS, KITCHEN SINK REPLACED WITH NEW. EXACT LOCATION
ELECTRIC WATER HEATER TO BE REPLACED WITH NEW
MECHANICAL:
EXIST A/C COMPRESSOR TO BE RAISED AND PLACED ON NEW CONCRETE SLAB
14'-6"
I I
EXIST BRNG.PARTITION-------------NEW INFILL WALL -—EXIST BRNG.PARTITION—►
OF FLO '
NOTE: COVER BOTH SIDES WITH 1/2" GWB
ALL ORIGINAL STRAPPING IN PLACE
A N.T.S.
!I'-. A 521 0e� A. RR
,
DETAIL �4
'QA's G CORF[�
€ Eqg
b ��1
Walter Antin 3 Architect LLC Title
FL# AR95210 2106 CAMPANELI— Q.L.V .
1500 Pennsylvania Ave, Unit #8 Drawing Number Drawn By Date
Miami Beach Fl. 33139 261012 J.A. P. 10-26-12
Tel: 305-877-3264 CAD File Name Page No.
FLOOR PLAN WTH REPAIRS A-1
7 8 9 1 10 1 11 1 12
SIMPSO
1
EXIST
2-2 x 12
HEADERS
STUD
_
16"
oo
TYP
- ------ -
2X6
STUD
TYP
2X6
FIRESTOP
MIDWAY
TYP
°
SIMPSON
3/16"X 3"
SP -6 TYP
TAPCON
EA.STUD
2X6 PT
TYP
I I
EXIST BRNG.PARTITION-------------NEW INFILL WALL -—EXIST BRNG.PARTITION—►
OF FLO '
NOTE: COVER BOTH SIDES WITH 1/2" GWB
ALL ORIGINAL STRAPPING IN PLACE
A N.T.S.
!I'-. A 521 0e� A. RR
,
DETAIL �4
'QA's G CORF[�
€ Eqg
b ��1
Walter Antin 3 Architect LLC Title
FL# AR95210 2106 CAMPANELI— Q.L.V .
1500 Pennsylvania Ave, Unit #8 Drawing Number Drawn By Date
Miami Beach Fl. 33139 261012 J.A. P. 10-26-12
Tel: 305-877-3264 CAD File Name Page No.
FLOOR PLAN WTH REPAIRS A-1
7 8 9 1 10 1 11 1 12