14-15482D 2A 2B,2J C WP EE 2A,2G,2H 2A,2G,2H v 2D ` 2D f H 2B,2J D 2G,2H 2D H 2G,2 TO FACP 2G,2H r« 2G,2H Ly 2G,2H C C SCOPE OF WORK ' CONVERT DUCT DETECTOR HARDWIRE IDC ZONES TO IDNET SLC's. REMOVE EOL RESISTOR FROM DUCT DETECTOR IDC's. REPLACE ALL EXISTING (15) DUCT > DETECTORS WITH ADDRESSABLE TWO -WIRE DUCT DETECTORS. REMOVE EXISTING FACP. REPLACE WITH NEW 4010ES. EXISTING IDC's AND NAC's > TO REMAIN. ZONE 3 2D ZONE 2 ZONE 4 ZONE 1 D -MM S -MM A,G,H D 2A, B,J B,J R, D IA,G,H 2A, L S FI A,G,H D > 2A ` 2D D 2A ' INSTALL NEW 4003EC VOICE CONTROL PANEL. CONNECT TO EXISTING SPEAKERS. 2A JF S L TO FACP L S F 2A,2G,2H �- 2A,2G,2H TO FACP 2A,2G,2H 5 .2D R s 2D$ C L S 2D,1 2A,213 2H 2A � s ME HR I, 4'� FS -1 2D F 1. Y 2D 2B,2J -� 0 SIMPLEX FIRE ALARM, NURSE CALL. SECURITY SYSTEMS, CCN. ELECTRONIC ACCESS CONTROL, \ INTEGRATED COMMUNICATION SYSTEMS, �\ HR TIME CONTROL SYSTEMS, INSTALLATION, AND MONITORING �\ E,F CONFIDENTIAL SIMPLEX INFORMATION \ 1992 SIMPLEX TIME RECORDER CO. F GARDNER. MA. 01441 S F- 75 W m CD H 2D -/ S 2D 2G,2 2D 2D,1 2D,1 I HR l HR H 2D 2D H L WP 213 2D L S F D B,J 2A,2G,2H TO FACP 2A,2G,2H A,G,H TO FACP TO FACP TO FACP SYSTEM ❑PERATI❑N GENERAL ALARM W/ AHU SHUTDOWN AND OVERHEAD DOOR RELEASE, DUCT DETECTOR LOCATIONS (PER INSPECTION REPORT): 1. GYM ZN2 2. GYM ZN2 3. GYM ZN2 4. GYM ZN2 5. LADIES ROOM 6. STORAGE ROOM ZN2 7. MENS ROOM ZN2 8. NORTH MEETING ROOM 9. SOUTH MEETING ROOM � 10. ANNEX BLDG. ZN6 11. MAIN ENTRANCE S 12. NORTH GAME ROOM ZN6 � 13. SOUTH GAME ROOM ZN2 14. WEIGHT ROOM t 15. COMPUTER ROOM � SYMBOL LEGEND ® PULL STATION Q SMOKE DETECTOR FH1 HEAT DETECTOR D: DUCT SMOKE DETECTOR EN HORN OO HORN / STROBE (N SPEAKER @Q0 SPEAKER / STROBE Sub Total STROBE aF FIREMAN'S PHONE 19 DOOR HOLDER " R1 RELAY (BY OTHERS) In REMOTE TEST SWITCH ® WATERFLOW SWITCH ® TAMPER SWITCH ® FIRE ALARM TERMINAL CABINET F TAAPI FIRE ALARM ANNUNCIATOR PANEL FACP FIRE ALARM CONTROL PANEL WP WEATHERPROOF E ELEVATOR -'Wlr END -OF -LINE RESISTOR * B® BEAM DETECTOR (BY OTHERS) ZONE SCHEDULE ZONE 1 MANUAL PULL STATION ZONE 2 DUCT DETECTORS ZONE 3 BEAM DETECTORS ZONE 4 SMOKE/HEAT DETECTORS ZONE 5 PHASE II MANUAL ZONE 6 PHASE II DUCT DETECTORS ZONE 7 WATERFLOW ZONE 8 SPRINKLER SUPERVISORY F* NOTE: REMOTE RELAYS ® AND BEAM DETECTORS g� BY OTHERS. FIRE ALARM - EZELL HESTER COMMUNITY CENTER, BOYTON BEACH i M ti O N co N 't 0 W z a DEVICE PLACEMENT PLAN SCALE: NTS N_ co M X N TO EXISTING STROBES TO EXISTING SPEAKERS 4010ES FACP 120 VOLT AC SS 4003EC VCC 120 VOLT AC �M R M1-1 0 VCC ACTIVATE M R M1-2 AIM VCC IN ALARM M R M1-3 AIM VCC IN TROUBLE B - TO NEW IDNET DUCT DETECTORS 2A,C,D,E,F TO EXISTING HARDWIRE DEVICES J TO AHU SHUTDOWN ec-P3 INwmvows REOOD. u11y0i TEMPORARY l TOw toy REVIEWED BYA TE 0 al 'al anical !ester Other. u� I Fr0cesc.^d oiecd on this p �It s T3 0 Coy ivy po �n h S e ,z--- EZELL NESTER 4010es FACP WIRE LEGEND 4010es A - 2 #14 PULL STATION Standby Current __: 13 _ 2 - #14 T DUCE DETECTOR E Sub Total C - 2 #14 / 2 #12 BEAM DETECTOR _ 4010-9402 1 D - 2 #14 SMOKE DETECTOR 0.4300 0.4300 E - 2 #14 WATERFLOW 0.0300 0.0300 F - 2 #14 TAMPER 8 ZONE INtT1ATING DEVICE CIRCUIT - CLASS B + G - 2 #14 HORN/STROBE 0.1950 ZDNet Addressable Devices H - 18 TSP SPEAKER 0.6650 I - 2 #14 CONTROL DOOR RELEASE 0.0000 0.0000 J - 2 #14 AHU SHUTDOWN IDNET RELAY IAM * M - 18 TSP IDNET 0.0000 R - 2 #18 RELAY (DRY CONTACT) 0.0000 1 0.0000 ZONE SCHEDULE ZONE 1 MANUAL PULL STATION ZONE 2 DUCT DETECTORS ZONE 3 BEAM DETECTORS ZONE 4 SMOKE/HEAT DETECTORS ZONE 5 PHASE II MANUAL ZONE 6 PHASE II DUCT DETECTORS ZONE 7 WATERFLOW ZONE 8 SPRINKLER SUPERVISORY F* NOTE: REMOTE RELAYS ® AND BEAM DETECTORS g� BY OTHERS. FIRE ALARM - EZELL HESTER COMMUNITY CENTER, BOYTON BEACH i M ti O N co N 't 0 W z a DEVICE PLACEMENT PLAN SCALE: NTS N_ co M X N TO EXISTING STROBES TO EXISTING SPEAKERS 4010ES FACP 120 VOLT AC SS 4003EC VCC 120 VOLT AC �M R M1-1 0 VCC ACTIVATE M R M1-2 AIM VCC IN ALARM M R M1-3 AIM VCC IN TROUBLE B - TO NEW IDNET DUCT DETECTORS 2A,C,D,E,F TO EXISTING HARDWIRE DEVICES J TO AHU SHUTDOWN ec-P3 INwmvows REOOD. u11y0i TEMPORARY l TOw toy REVIEWED BYA TE 0 al 'al anical !ester Other. u� I Fr0cesc.^d oiecd on this p �It s T3 0 Coy ivy po �n h S e ,z--- EZELL NESTER 4010es FACP 4010es Module Qty Description Sub Total Standby Current Tota ' Standby `Alarm_ Current --Total Alarm Panel Equipment = 0.0180 Sub Total 0.4354 6.6830 Spare addressable point capacity 0% 0 x 0.0008 4010-9402 1 FACP, 248PT IDNET, 1 BAY, 120V, PLATINUM * 0.3160 0.3160 0.4300 0.4300 4010-9912 1 SERIAL DACT 0.25 x 6.683 0.0300 0.0300 0.0400 0.0400 4010-9920 1 8 ZONE INtT1ATING DEVICE CIRCUIT - CLASS B + 0.0750 0.0750 0.1950 0.1950 ZDNet Addressable Devices SLC Panel Totals + 0.4210 0.6650 4090-9001 2 IDNET SUPERVISED IAM * 0.0000 0.0000 0.0000 0.0000 4090-9002 1 IDNET RELAY IAM * 0.0000 0.0000 0.0000 0.0000 4098-9755 15 TRUEALARM DUCT SMOKE SENSOR W/O RELAY OUTPUT * 0.0000 0.0000 1 0.0000 0.0000 Notification Appliances Alarm Current 2.0000 Circuit NAC EXIST -DEV 1 3 1EXISTING SG NOTIFICATION APPLIANCES Power 0.0000 0.0000 2.0000 6.0000 Wire Res. Total V. Drop Peripheral Totals % Volt 0.0000 6.0000 Output Branch Circuit/ RUI Totals 0 0.0000 Cld. 0.0000 Gauge Ft. R Alarm A Address Totals 18 Addresses 0.0144 Voltage 0.0180 0.4354 l 6.6830 Select ALL Power Supplies on this battery set: 4010es 0.4210 6.6650 Sub Total 0.4210 6.6650 Additional Current Draws: MAPNET/ZDNet Device Addresses ordered / used 18 x 0.000800 = 0.0144 x 0.001000 = 0.0180 Sub Total 0.4354 6.6830 Spare addressable point capacity 0% 0 x 0.0008 = 0.0000 x 0.001 = 0.0000 Total 0.4354 6.6830 Standby Time = 24 Hrs x 0.4354 = 10.4496 Standby Ah Alarm Time = 15 Min 0.25 x 6.683 1.6708 Alarm Ah WIRE RESISTANCE BASED ON TABLE 8 FROM NATIONAL ELECTRICAL CODE (UNCOATED STRANDED COPPER WIRE) ® 12.1204 Additional Spare Battery Capacity = 0% + 0.0000 • Device Type 12.1204 Minimum Battery Discharge Factor = 20% + 2.4241 Minimum Battery Required 2081-9275 18AH (2x) 14.5444 Battery Supplied 2081-9275 18AH 2x EZELL NESTER 4010es FACP VOLTAGE DROPS PID EXIST -DEV Candela WIRE RESISTANCE BASED ON TABLE 8 FROM NATIONAL ELECTRICAL CODE (UNCOATED STRANDED COPPER WIRE) ® 75 Celsius • Device Type Minimum 2 Device as Supv. Current 0.0000 Voltage ® Spare Quantity Alarm Current 2.0000 Circuit NAC Circuit / Per Power Panel Plan Dist. (D) Wire Wire Res. Total V. Drop Volt % Volt Min Device Max Crpacity Output Branch Circuit/ NOTIFICATION CIRCUIT DESCRIPTION Supply Circuit Cld. Feet Gauge Ft. R Alarm A A*2D*R 0 End Drop Voltage Distance Ams) Terminals Capacity Branch SIGt 4010es SIG1 V1 250 1490 0.0031 2.000 3.140 16.360 16.10% 16vdc 279 Ft. 1 3A 19.5 10.3% 1 SIG2 4010es SIG2 V2 250 1490 0.0031 2.000 3.140 16.360 16.10% 16vdc 279 R. 1 3.A 19.5 10.3% 1 SIG3 4010es SIM V3 250 1490 0.0031 2.000 3.140 16.360 16.10%1 16vdc 279 Ft. 1 3A 19.5 10.3% 1 SPARE 4010es SIG4 V4 1490 0.0031 0.000 0.000 19.500 0.00%1 16vdc 0 Ft. 3A 19.5 100.0% 0 a� vo h N ti rr v .� O za N W�tit �J � Y a a1JUr- y.. P! OCe 0-r of � �-ILt 4 £9 a" G' Timothy C. Trewyn, PE P.E. No. 61580 ENGINEER SEAL Fort Pierce Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design C.A. No. 28173 315 South 7th Street Fort Pierce, FL. 34950 Phone: 772 672-4636 Fax: 772 672-4637 O L Es Cf)W 0 Y S U Uj O 1 LU O J W N REV -0 DRAWN BY: ES CHECKED BY: ISSUE DATE: 2014-04-23 JOB #: 977412001 PROJECT #: i 977412001 SIMPLEXGRINNELL © 2014 SYSTEM: FIRE ALARM SHEET: FIRE ALARM PANEL REPLACEMENT FA -01 a • 2 as O L Es Cf)W 0 Y S U Uj O 1 LU O J W N REV -0 DRAWN BY: ES CHECKED BY: ISSUE DATE: 2014-04-23 JOB #: 977412001 PROJECT #: i 977412001 SIMPLEXGRINNELL © 2014 SYSTEM: FIRE ALARM SHEET: FIRE ALARM PANEL REPLACEMENT FA -01