16-3319Design No. U419
Nonbearing Wall Ratings -1, 2, 3 or 4 Hr (See Items 3 &4)
1. Floor And Ceiling Runners - (Not shown) - Channel shaped, fabri-
cated from min 25 MSG (min 20 MSG when Item 4A is used) corrosion -
protected steel, min width to accommodate stud size, with min 1 in.
long legs, attached to floor and ceiling with fasteners 24 in. OC max.
2. Steel Studs - Channel shaped, fabricated from min 25 MSG (min 20
MSG when Item 4A is used) corrosion -protected steel, min width as
indicated under Item 4, min 1-1/4 in. flanges and 1/4 in. return, spaced
a max of 24 in. OC. Studs to be cut 3/8 to 3/4 in. less than assembly
height.
3. Batts and Blankets* - (Required as indicated under Item 4) - Min-
eral wool batts, friction fitted between studs and runners. Min nam
thickness as indicated under Item 4. See Batts and Blankets (BKNV or
BZJZ) Categories for names of Classified companies.
3A. Batts and Blankets* - (Optional) - Placed in stud cavities, any glass
fiber or mineral wool insulation bearing the ITL Classification Marking
as to Surface Burning Characteristics and/or Fire Resistance. See Batts
and Blankets (BKNV or BZJZ) Categories for names of Classified com-
panies.
4. Gypsum Board* - Gypsum panels with beveled, square or tapered
edges, applied vertically or horizontally. Vertical joints centered over
studs and staggered one stud cavity on opposite sides of studs. Vertical
joints in adjacent layers (multilayer systems) staggered one stud cavity.
Horizontal edge joints and horizontal butt joints on opposite sides of
studs need not be staggered. Horizontal edge joints and horizontal butt
joints in adjacent layers (multilayer systems) staggered a min of 12 in.
The thickness and number of layers for the 1 hr, 2 hr, 3 hr and 4 hr rat-
ings are as follows:
Wallboard Protection on Each Side of Wall
Rating Min Stud No. of Layers Min. Thkns
Depth & Thkns of Insulation
of Panel (Item 3)
1 3-1/2 1 layer, 5/8 in. thick Optional
1 2-1/2 llayer, 1/2 in. thick 1-1/2 in -
1 1-5/8 1 layer, 3/4 in. thick Optional
2 1-5/8 2 layers, 1/2 in. thick Optional
Use 6" Studs - 2 1-5/8 2 layers, Sl8 in. thick Optional
Wall Legend 2 3-1/2 1 layer, 3/4 in. thick 3
3 1-5/8 3 layers, 1/2 in. thick Optional
3 1-5/8 2 layers, 3/4 in. thick Optional
3 1-5/8 3 layers, 5/8 in. thick Optional
4 1-5/8 4 layers, 5/8 in. thick Optional
4 1-5/8 4 layers, 1/2 in. thick Optional
4 2_1/2 2 layers, 3/4 in. thick —
CANADIAN GYPSUM COMPANY -1/2 in. thick Type C,
IP -X2 or IPC -AR; 5/8 in. thick Type AR, C IP -AR, IP -XI,
IP -X2, IPC -AR, SCX, SHX, WRX or WRC; 3/4 in thick Type
IP -X3, ULTRACODE, ULTRACODE SHX or ULTRACODE WRX
UNITED STATES GYPSUM CO - 1/2 in. thick Type C, IP -X2,
IPC -AR or WRC; 5/8 in. thick TYPe SCX, SHX, WRX, IP-Xl,
AR, C WRC, FRX-G, INAR, IP -X2, IPC -AR; 3/4 in. thick Type
IP -X#, ULTRACODE, ULTRACODE SHX or ULTRACODE WRX
4A. Gypsum Board* - (As an alternate to Item 4) - 5/8 in. thick gypsum
panels, installed as described in Item 4 with Type S-12 steel screws. The
length and spacing of the screws as specified under Item 5.
CANADIAN GYPSUM COMPANY - Type FRX
UNITED STATES GYPSUM CO - Type FRX
4B. Gypsum Board* - (As an alternate to Item 4 and 4A) - 5/8 in.
thick, 2 ft. wide, tongue and groove edge, applied horizontally as the
outer layer to one side of the assembly. Secured as described in Item 5.
Joint covering (Item 7) not required.
CANADIAN GYPSUM COMPANY - Type FRX
UNITED STATES GYPSUM CO - Type FRX
5. Fasteners - (Not Shown) - Type S or S-12 steel screws used to attach
panels to studs (Item 2) or furring channels (Item 6). Single Layer sys-
tems: 1 in. long for 1/2 and 5/8 in thick panels or 1 1/4 in. long for
3/4 in. thick pnaels, spaced 8 in. OC when panels are applied horizon -
ally, or 12 in. OC when panels are applied vertically. Two layer sys-
tems: First layer - 1 in. long for 1/2 and 5/8 in. thick panels or 1 1/4 in.
long for 3/4 in. thick panels, spaced 16 in. OC. Second layer - 15/8 in.
long for 1/2 in., 5/8 in. thick panels or 2-1/4 in long for 3/4 in. thick
panels, speed 16 in. OC with screws offset 8 in from first layer. Three -
layer systems: First layer - 1 in. long for 1/2 in., 5/8 in. thick
spaced 24 in. OC. Second layer - 1-5/8 in. long for 1/2 in., 5/8 in. thick
panels, spaced 24 in. OC. Third layer - 2-1/4 in. long for 1/2 in., 5/8 in.
thick panels or 2-5/8 in. long for 5/8 in. thick panels, spaced 12 in. OC.
Screws offset min 6 in. from layer below. Four -layer systems: First
layer - 1 in. long for 1/2 in., 5/8 in. thick panels, spaced 24 in. OC. Sec-
ond layer - 1-5/8 in. long for 1/2 in., 5/8 in. thick panels,spaced 24 in.
OC. Third layer - 2-1/4 in. long for 1/2 in. thick panels or 2-5/8 in. long
for 5/8 in. thick panels, spaced 24 in. OC. Fourth layer - 2-5/8 in. long
for 1/2 in. thick panels or 3 in. long for 5/8 in. thick panels, spaced 12
in. OC. Screws offset min 6 in from layer below.
6. Furring Channels - (Optional, not shown, for single or double layer
systems) - Resilient furring channels fabricated from min 25 MSG
corrosion -protected steel, spaced vertically a max of 24 in. OC. Flange
portion attached to each intersecting stud with 1/2 in. long Type S-12
steel screws. Not for use with Item 45A.
7. Joint Tape and Compound - Vinyl or casein, dry or premixed joint
compound applied in two coats to joints and screw heads of outer lay-
ers. Paper tape, nom 2 in. wide, embedded in first layer of coumpound
over all joints of outer panels.
8. Siding, Brick or Stucco - (Optional, not shown) - Aluminum, vinyl
or steel siding, brick veneer or stucco, meeting the requirements of
local code agencies, installed over gypsum panels. Brick veneer
attached to studs with corrugated metal wall ties attached to each stud
with steel screws, not more than each sixth course of brick.
9. Caulking and Sealants* - (Optional, not shown) - A bead of acous-
tical sealant applied around the partition perimeter for sound control.
UNITED STATES GYPSUM CO - Type AS
*Bearing the UL Classification Mark
9 0
1 r17A 11
BOYN ON ][3 ACI[4 FLOR11D
TENANTo P02 PRODUCTS BY 02
y
AREA SUMMARY: (SUITE 300)
Gi
CODE INFORMATION:
EXISTING AREA SUMMARY
2014 FLORIDA BUILDING CODE — 5TH EDITION
FIRST FLOOR
(D
LEVEL OF ALTERATION: LEVEL 2
(EXISTING) HEATED (OFFICE) AREA
= 2,108 SF
BOYNTON BEACH ZONING
HEATED (LABS/WORKAREA) AREA
= 2,075 SF
SECTION 8. M-1 INDUSTRIAL DISTRICT REGULATIONS AND USE PROVISIONS
UNHEATED (STORAGE) AREA
= 2,248 SF
A. M-1 INDUSTRIAL DISTRICT PARAGRAPH 1, SUBSECTION B, ITEM 11
UPPER FLOOR
C'7
M
— RESEARCH AND DEVELOPMENT LABORATORIES
UNHEATED (STORAGE) AREA =
2,108 SF
FLORIDA BUILDING CODE
GROUP B,
m
JE
�
SECTION 305, BUSINESS OCCUPANCY —
TOTAL AREA
-+--►
LABORATORIES; TESTING AND RESEARCH (NONHAZARDOUS)
(HEATED AND UNHEATED) =
8,539 SF
EXISTING BUILDING CONSTRUCTION: TYPE II—B — SPRINKLERED
Q
U)
TABLE 500 — ALLOWABLE HEIGHTS/BUILDING AREAS
O
(F— FACTORY/INDUSTRIAL OCCUPANCY)
��
o
MAX. HEIGHT IN FEET = 55 FT.
�
MAX. NO. OF STORIES = 4
ONO-
AREA: MUTLISTORY = 42,000 S.F. PER FLOOR
(
ONE STORY ONLY = 63,000 S.F.
VCf)
WC
TABLE 500 — ALLOWABLE HEIGHTS/BUILDING AREAS
=mo
(B— BUSINESS OCCUPANCY)
MAX. HEIGHT IN FEET = 55 FT.
-
J
Q
MAX. NO. OF STORIES = 5
C
Z
AREA: MULTISTORY = 34,000 S.F. PER FLOOR
L�
0
ONE STORY ONLY = 51,000 S.F.
GMr
TABLE 600 REQUIREMENTS:
•—,
INTERIOR BEARING WALLS — NC
co
cY)
COLUMNS — NC
BEAMS, GIRDERS, TRUSSES — NC
W
FLOORS/FLOOR CEILING ASSEMBLIES — NC
CU
ROOF/ROOF CEILING ASSEMBLIES — NC
TENANT SEPARATION — 2 HOURS
OCCUPANCY SEPARATION (OFFICES/STORAGE) — 2 HOURS
Q
TENANT UPFIT OCCUPANCY GROUP: BUSINESS (GROUP B)
�
MINIMUM OCCUPANCY LOAD — GROUP B = 100 S.F. GROSS
MAX. DISTANCE TO EXIT (SPRK.) — GROUP B = 300 FT.
MAX. DEAD END CORRIDOR — GROUP B = 20 FT., CAN BE 50 FT.
(see note: 20)
EGRESS WIDTH — GROUP B
LEVEL = 0.2
STAIRS = 0.3
MIN. CORRIDOR/AISLE — GROUP B = 44 IN., 36 IN., IF SERVES
LESS THAN 50 PEOPLE
MIN. CLEAR OPENING EXIT DOORS — GROUP B = 32 IN.
MIN. STAIR WIDTH — GROUP B = 44 IN.
MINIMUM OCCUPANT LOAD — SUITE 300
OCCUPANCY — BUSINESS
REQUIRED:100 SF/PERSON
FIRST FLOOR: 4,183 SF/100 = 41.83 (USE 42) OCCUPANTS
ACTUAL: 16 OCCUPANTS
OCCUPANCY — STORAGE (S-2)
REQUIRED: 300 SF/PERSON
FIRST FLOOR: 2,248 SF/300 = 7.49 (USE 8) OCCUPANTS
ACTUAL: 2 OCCUPANTS
Issue Date:
Gi
C�
M
(D
■
W
co
N
C
O
C'7
M
=
O
M
M
m
JE
�
ry
(,�
-+--►
O
40
Gi
C�
M
(D
W
co
N
C
O
C'7
M
=
O
M
M
m
JE
�
ry
(,�
-+--►
O
Q
U)
•L
O
��
o
O
�
�
ONO-
U
(
•CD
VCf)
WC
=mo
o
-
J
Q
O
Np
C
Z
cu
L�
0
C:
GMr
•—,
co
cY)
v
W
CU
0
co
Q
�
40
Gi
M
H
N
N
O
C'7
M
0
m
ry
CU
Cl)
•o
Z
O
i.L,
o
�
�
U
N
•CD
t0
=mo
-
J
Q
O
Np
C
C:
M
O
C:
C:
QO
m
Z
W
Date:
5.18.2016
Project Number:
Designed By:
Drawn By:
Checked By:
Sheet Title:
Sheet Number:
CVR
O
LO
N
co
I
N
N
/EXSTG. ROOF
f� CONSTRUCTION
LA-) 28" BAR JOIST
EXSTG. FLR. SLAB
A1.4 VERTICAL HEIGHT -
STORAGEMAREHOUSE
SCALE: 3/8" = V-0"
LEGEND/SPECIFICATION:
F.E. = FIRE EXTINGUISHER
"Larsen" MP Series, Multi—Purpose Dry Chemical
Model MP5, Standard Bracket, UL Rating 2A -10B: C
This Is A Minimum Specification And Shall Be Verified
With Fire Marshall.
Location Of Fire Extinguishers Shall Be Verified With
Fire Marshall.
MINIMUM OCCUPANT LOAD — SUITE 300
OCCUPANCY — BUSINESS
REQUIRED:100 SF/PERSON
FIRST FLOOR: 4,183 SF/100 = 41.83 (USE 42) OCCUPANTS
ACTUAL: 16 OCCUPANTS
OCCUPANCY — STORAGE (S-2)
REQUIRED: 300 SF/PERSON
FIRST FLOOR: 2,248 SF/300 = 7.49 (USE 8) OCCUPANTS
ACTUAL: 2 OCCUPANTS
DOOR SCHEDULE
DOOR
DETAILS
FRAME
HARDWARE
REMARKS
NO
DESCRIP11ON
WIDTH
HEIGHT
THICKNESS
TYPE
I MATERIAL
FINISH
ELEV
HEAD
JAMB
SILL
MATL.
FIN
LABEL
C�
1
EXISTING DOOR
S-0"
7'-0"
1 3/4"
SWING
WD.
-
-
-
-
-
WD.
PAINT
(EXSTG.)
EXISTING
RELOCATED - SEE NEW FLOOR LAYOUT FOR LOCATION.
2
EXISTING DOOR
S -O"
1 7'-0"
1 3/4"
SWING
MTL
-
-
-
-
-
MTL.
PAINT
(EXSTG.)
EXISTING
REMOVE AND REVERSE SWING AS SHOWN ON NEW
FLOOR LAYOUT.
•—,
W
o
'CU
Q
m
a)
A1.3 PART. FIRST FLOOR PLAN - SUITE 300 (LIFE SAFETY)
SCALE: 1/8" = V-0"
A1.2 PART. FIRST FLOOR PLAN - SUITE 300 (NEW LAYOUT)
SCALE: 1/8" = V-0"
WALL LEGEND
o EXSTG. WALL CONSTRUCTION
® EXSTG. RATED GYP. BD. WALL
UP TO BOTTOM OF ROOF DECKING
® EXSTG. 2 HR. RATED GYP. BD. WALL
(TENANT SEPARATION) UP TO BOTTOM
OF ROOF DECKING
EXSTG. 2 HR. RATED WALL UP TO BOTTOM OF ROOF DECKING —
6" (20 GA.) STL. STUDS AT 16" O.C. WITH (2) LAYERS
5/8" FIRECODE GYP. BD. EACH SIDE. FIRE SEAL AROUND
ROOF JOIST PENETRATIONS AND ROOF DECK VOIDS.
SEE U.L. DESIGN NUMBERS. LABEL WALL — "2 HR FIRE WALL —
PROTECT ALL PENETRATIONS"
NEW WALL IN—FILL: 2 HR. RATED WALL —
6" (20 GA.) STL. STUDS AT 16" O.C. WITH (2) LAYERS
5/8" FIRECODE GYP. BD. EACH SIDE.
SEE U.L. DESIGN NUMBERS. LABEL WALL — "2 HR FIRE WALL —
PROTECT ALL PENETRATIONS"
A1.1 PART. FIRST FLOOR PLAN - SUITE 300 (EXISTING / DEMOLITION PLAN)
SCALE: 1/8" = V-0"
Issue Date:
Revisions
Wc3
C:
■
00
C�
�U)70C
Q
_C
N N
M o
M m
CU CO
•L U
O
u- O
L
A
U N
N0
m 0-
C -�j
O CU
C C
A O
m ~
Date:
5.18.2016
Project Number:
Designed By:
Drawn By:
Checked By:
Sheet Title:
PART. FLOOR PLANS,
WALL LEGEND,
DOOR SCHEDULE,
VERTICAL HEIGHT
Sheet Number:
lhft�Al
Wc3
C:
M
00
C�
�U)70C
Q
_C
O04
(0U�
t'W
oc,
O
CY)
Z
�
c0
�-
C'r3
LO
Q
Cl)
coCQ
•—,
W
o
'CU
Q
m
a)
N N
M o
M m
CU CO
•L U
O
u- O
L
A
U N
N0
m 0-
C -�j
O CU
C C
A O
m ~
Date:
5.18.2016
Project Number:
Designed By:
Drawn By:
Checked By:
Sheet Title:
PART. FLOOR PLANS,
WALL LEGEND,
DOOR SCHEDULE,
VERTICAL HEIGHT
Sheet Number:
lhft�Al