16-49534' CHAIN LINK '' '" FENCE 130 tt_ PROPERTY LINE SUNSET RD POOLDESIGN. NET DESIGN PER FLORIDA BUILDING CODE 454.2 W 454.2.6.6 /R4101.6.1 ENTRAPMENT PROTECTION FOR Z 454.2.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS Q LU .J z J Lu w >; Iii Lij CL i'- Qf NSPI 3, ANSI/NSPI 5, 0 w a THE FOLLOWING IS DETERMINED BY RATIONAL ANALYSIS. SOIL CONDITIONS 3) IN THIS AREA HAVE BEEN BY PAST EXPERIENCE CAPABLE OF SUPPORTING A Z sra CL 4) ALL CONCRETE SHALL CONFORM TO A.C.I 318-11. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI FOR PNEUMATICALLY PLACED DESIGN PER FLORIDA BUILDING CODE 454.2 INCLUDING BUT NOT LIMITED TO 454.2.6.6 /R4101.6.1 ENTRAPMENT PROTECTION FOR SUCTION INLETS 454.2.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS REVISIONS GENERAL NOTES: 1) PLANS DESIGNED PER 2014 5th EDITION F.B.C. RESIDENTIAL CHAPTERS 42 & 45 and ANSI/ NSPI 3, ANSI/NSPI 5, ANSI/APSP 7,ANSI/APSP/ICC 15 2) THE SITE HAS UNDISTURBED SAND, ROCK, SAND AND ROCK, WITH A MINIMUM BEARING VALUE OF 1500 PSF. THE FOLLOWING IS DETERMINED BY RATIONAL ANALYSIS. SOIL CONDITIONS 3) IN THIS AREA HAVE BEEN BY PAST EXPERIENCE CAPABLE OF SUPPORTING A POOL AND DECK OF SIMILAR SIZE AND DEPTH. IF CONDITIONS DIFFER FROM CONDITIONS SPECIFIED ABOVE, THIS ENGINEER SHALL BE NOTIFIED PRIOR TO FURTHER CONSTRUCTION OF THIS PROJECT. 4) ALL CONCRETE SHALL CONFORM TO A.C.I 318-11. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI FOR PNEUMATICALLY PLACED CONCRETE (GUNITE/SHOTCRETE) ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BARS OR NEW 5) BILLET STEEL CONFORMING TO A.T.S.M: 15. STEEL SHALL BE BENT, LAPPED, AND PLACED IN ACCORDANCE WITH A.C.I. STANDARDS AND SPECIFICATIONS. PIPING; ALL POOL PIPING SHALL BEAR THE N.S.F: PW SEAL OF APPROVAL AND 6) SHALL BE SCHEDULE 40 P.V.C. MIN. POOL PIPING TO COMPLY WITH F.B.C. POOL EQUIPMENT TO APPLY TO F.B.C. I WATER SUPPLY AND DISPOSAL SHALL BE SO ARRANGED THAT THERE IS NO CROSS 7) CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM AND SHALL MEET ALL REQUIREMENTS iN F.B.C. EQUIPOTENTIAL BONDING GRID SHALL BE INSTALLED PER"2011 NEC SECTION 8 680.26(C) PAUL CHARETTE ARCHITECT 2528 N 38 th Ave Holl ywood.FL�33 nA 561.756 6094^ A ra1ii�) PAUL CHA�,E`(Ef , AR - 0016 '9 ° POOL AREA PLAN TITLE TREMBLAY RESIDENCE DESCRIPTION 3010 PINE TREE LN, BOYNTON BEACH FL 33435 Scale: lin = 10ft. Oin. DATE 11/22/2016 PAGE 1 OF 4 m 7 ft. 8 in. 0" 11 ft. 11 in. 20" -10" R 4'-2" POOL MAY CAUSE UNDERMINING OF EXISTING STRUCTURES, PROVIDE SHORING BETWEEN POOL AND EXISTING STRUCTURES ---- W (7 U Z Z H W 1"x1/8" METAL STRAP U) U) ATTACHED TO EXISTING X to W W FOOTER WITH 2 SHOTS INTO CONCRETE AT 4 EACH 2x4 m VIRGIN SOIL 4'-0" WIDE by 8'-0" LONG by 1/2" THICK PLYWOOD SHEET ATTACHED WITH NAILS / @12" C/C IN EACH 2x4 2"x4"s @ 12" C/C ANGLE OF REPOSE DETAIL NTS Dnnr r))7QT(:7%I NFT R T-6" S ,�, 4' DEEP R 6-6" OD �• i R 8'-10' in. � r, ft DESIGN PER FLORIDA BUILDING CODE 454.2 INCLUDING BUT NOT LIMITED TO 454.2.6.6 /R4101.6.1 ENTRAPMENT PROTECTION FOR SUCTION INLETS 454.2.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS REVISIONS GENERAL NOTES: 1) PLANS DESIGNED PER 2014 5th EDITION F.B.C. RESIDENTIAL CHAPTERS 42 & 45 and ANSI/NSPI 3, ANSI/NSPI 5, ANSI/APSP 7,ANSI/APSP/ICC 15 y 2) THE SITE HAS UNDISTURBED SAND, ROCK, SAND AND ROCK, WITH A MINIMUM / BEARING VALUE OF 1500 PSF. r R 3'-3" THE FOLLOWING IS DETERMINED BY RATIONAL ANALYSIS. SOIL CONDITIONS IN THIS AREA HAVE BEEN BY PAST EXPERIENCE CAPABLE OF 3) SUPPORTING A POOL AND DECK OF SIMILAR SIZE AND DEPTH. IF 1 36 ft. 4 in. , CONDITIONS DIFFER FROM CONDITIONS SPECIFIED ABOVE, THIS 5' DEEP ENGINEER SHALL BE NOTIFIED PRIOR TO FURTHER CONSTRUCTION OF THIS PROJECT. a 4) ALL CONCRETE SHALL CONFORM TO A.C.I 318-11. CONCRETE SHALL HAVE A 3' CHEEP MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI FOR PNEUMATICALLY PLACED CONCRETE (GUNITESHOTCRETE) _C r �_ _...---- —a2 ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BARS OR 5) NEW BILLET STEEL CONFORMING TO A.T.S.M.-15. STEEL SHALL BE BENT, LAPPED, AND PLACED IN ACCORDANCE WITH A.C.I. STANDARDS AND SPECIFICATIONS. 29 5 i� �� N % -42" PIPING: ALL POOL PIPING SHALL BEAR THE N.S.F.-PW SEAL OF APPROVAL AND -30118) SHALL BE SCHEDULE 40 P.V.C. MIN. POOL PIPING TO COMPLY WITH F.B.0 . POOL EQUIPMENT TO APPLY TO F.B.C. m , R 6-0" -20n t3 t- - WATER SUPPLY AND DISPOSAL SHALL BE SO ARRANGED THAT THERE IS NO f 1 r CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL t DEEP SYSTEM AND SHALL MEET ALL REQUIREMENTS IN F.B.C. .R 6-6" /-EQUIPOTENTIAL BONDING GRID SHALL BE INSTALLED PER 2011 NEC SECTION 8) 680.26(0 Flo PAUL CHARETTE ARCHITE c Co 2528 N 38 th Ave Hollywood �3�3 re)561 756 60,,9y N t e ey PAULA %SRI `fTE/ 0 AR 1627 LAYOUT PLAN TITLE TREMBLAY RESIDENCE DESCRIPTION 3010 PINE TREE LN, BOYNTON BEACH FL 33435 Scale: 1/4" = 1'-0" DATE 11/22/2016 PAGE 2OF4 POOj PIPING NOTES ALL PIPING TO BE PVC SCHEDULE 40 MINIMUM AND ALL PRESSURE PIPING AND MAIN DRAIN PIPING MUST BE PRESSURE TESTED PRIOR TO GUNITE (CONCRETE) PROVIDE 5 PIPE DIAMETERS CLEAR LENGTH BEFORE PUMPS ON SUCTION SIDE PIPING TO BE INSTALLED 18" MIN BELOW GRADE AND TRENCHES TO BE BACKFILLED W/ CLEAN SAND �� MI WELL WATER: IF POOL IS TO BE FILLED WITH WELL WATER PROVIDE PREFILTER WHEN FILLING POOL 122 ft. 6 in. PROPERTY LINE PIPING IS SHOWN SPACED FOR rnnln1GrT qPA AIR I INF Tn DESIGN PER FLORIDA BUILDING CODE 454.2 INCLUDING BUT NOT LIMITED TO 454.2.6.6 /R4101.6.1 ENTRAPMENT PROTECTION FOR SUCTION INLETS 454.2.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS REVISIONS GENERAL NOTES: 1) PLANS DESIGNED PER 2014 5th EDITION F.B.C. RESIDENTIAL CHAPTERS 42 & 45 and ANSI/NSPI 3, ANSI/NSPI 5, ANSI/APSP 7,ANSI/APSP/ICC 15 2) THE SITE HAS UNDISTURBED SAND, ROCK, SAND AND ROCK, WITH A MINIMUM BEARING VALUE OF 1500 PSF. THE FOLLOWING IS DETERMINED BY RATIONAL 3) ANALYSIS. SOIL CONDITIONS IN THIS AREA HAVE BEEN BY PAST EXPERIENCE CAPABLE OF SUPPORTING A POOL AND DECK OF SIMILAR SIZE AND DEPTH. IF CONDITIONS DIFFER FROM CONDITIONS SPECIFIED ABOVE, THIS ENGINEER SHALL BE NOTIFIED PRIOR TO FURTHER CONSTRUCTION OF THIS PROJECT. 4) ALL CONCRETE SHALL CONFORM TO A.C.1 318-11. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI FOR PNEUMATICALLY PLACED CONCRETE (GUNITE/SHOTCRETE) ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BARS 5) OR NEW BILLET STEEL CONFORMING TO A.T.S.M.-15. STEEL SHALL BE BENT, LAPPED, AND PLACED IN ACCORDANCE WITH A.C.I. STANDARDS AND SPECIFICATIONS. PIPING: ALL POOL PIPING SHALL BEAR THE N.S.F.-PW SEAL -OF APPROVAL 6) AND SHALL BE SCHEDULE 40 P.V.C. MIN. POOL PIPING TO COMPLY WITH F.B.C. POOL EQUIPMENT TO APPLY TO F.B.C. 7 WATER SUPPLY AND DISPOSAL SHALL BE SO ARRANGED THAT THERE IS NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM AND SHALL MEET ALL REQUIREMENTS iN F.B.C. EQUIPOTENTIAL BONDING GRID SHALL BE INSTALLED PER 2011 NEC 8) SECTION 680.26(C) PAUL CRARETTE ARQI -- 2528 N 38 th Ave H,614 igd IFL 3, 561.7"56 ,60,,94 fir, y0 `Y S PAUL CHS „ETT a. AR - 0016{3�n G PIPING PLAN TITLE TREMBLAY RESIDENCE DESCRIPTION 3010 PINE TREE LN, BOYNTON BEACH FL 33435 Scale: 1/4" = 1'-0" DATE 11/22/2016 PAGE 30F4 G.F.I. "J" BOX 5' MIN. ' (NOTE BELOW) n DECK DETAIL WOOD DECK ELECTRIC 3 #12 IN 1/2" BY OTHERS 11 CONDUIT I, PANEL POOL --- � --------------------------------- I PANEL ---, COMPAC ED,FILL II� CONTROLLEq HEATER - #8 AWG BARE SOLID HLORINATOR - �� COPPER BONDING I I I, I ; ; I JUMPER I ------------j '----------' ------------ --------- LIGHT CORD (IN CONDUIT) GFI PUMP 'I 12v TRANSFORMER :_____ BREAKERS C built into light) #8 AWG INSULATED COPPER 3 #12 IN 1/2" CONTROLLER WIRE EPDXY COATED (IN CONDUIT) CONDUIT 11 — — -— --— •-— -- —-- —-- #8 AWG INSULATED I COPPER WIRE EPDXY COATED (9(9 POOL PUMP COMPLIES WITH BLOWER 3hp PENTAIR 403.9 FBC 1-1/2 H.P. VS 8 AMP 16A POOL STEEL OVERLAP @ 48 TIMES DIAMETER ALL ELECTRICAL PER N.E.C. ALL METALLIC ITEMS WITHIN 5'-0" OF WATER'S EDGE OF POOL TO BE ALL EQUIPMENT TO BE INSTALLED BONDED WITH #8 SOLID INSULATED WIRE (UL listed) FROM POOL PER MANUFACTURER STEEL. ALL GROUND WIRES CONNECTED TO STEEL WITH BRASS SPECIFICATIONS GROUND LUGS...... G.F.I. OUTLET 10' MIN. AND 20' MAX. FROM POOL 3- #4 CONT. IN 10"X10"BEAM PILING POOL SEE PILING PLAN COAT BOND CONNECTION W/ APPROVED POTTING COMPOUND 12V UNDERWATER UL APPROVED LIGHT 6" WALLS WITH #3s @ 12" O/C HORIZONTAL & VERTICAL PLASTER. FINISH 6" FLOOR WITH #3s @ 12" O/C BOTH WAYS CD PROVIDE 3" MIN COVER TO BOTTOM REINFORCEMENT & 1.5" MIN. TO TOP REINFORCEMENT STRUCTURAL DETAIL ANTI -ENTRAPMENT Z AQUASTAR MAIN DRAIN 32CDFL101 - 316 o GPM @ 3.9 FPS Z FLOOR INSTALLATION 32' No POOL/ SPA MAIN DRAIN DETAIL �- — 1. TIME SWITCH MUST BE INSTALLED TO 3hp PENTAIR ALLOW POOL OWNERS TO RUN THE POOL VARIABLE FILTRATION PUMP ONLY DURING PEAK ij SPEED PUMP HOURS FILTER m 2. POOL FILTRATION PIPING MUST BE 3 -way valve = Provide min. SIZED SO THAT THE VELOCITY DOES NOT a 4 times pipe EXCEED 8FPS IN THE RETURN LINE AND MIN. 18" CLEAR diam. clear 6FPS IN THE SUCTION LINE. FOR FUTURE straight length 3. FILTER AREA BASED ON 6 HOUR TURN o SOLAR OVER FLOW RATE CONTROLLER 0� IC -40 CELL 0 4. FILTER PUMPS - A MIN. OF 4 PIPE DIAMETERS SHALL BE INSTALLED BEFORE PUMP. J O 2-1t2` POOL RETURN FILTER PAD DETAIL 3 WAY VALVE ACTUATOR(typ) LEGEND: O - RETURN LINE 3" 130 5.9 - ELEVATION 2-1/2" 130 8.5 - 2 -WAY VALVE 2-1/2" 130 8.5 - 3 -WAY VALVE 5. INLET FITTINGS SHALL BE - CHECK VALVE RETURN LINE - BUTTERFLY VALVE 51 SKIMMER M. - VALVE ACTUATOR NTS - NOT TO SCALE EQUIPOTENTIAL BONDING GRID / O POOL 1 �--0 PER 2011 NEC (680.26C "EQUIPOTENTIAL BONDING GRID"): #8 AWG WIRE BURIED IN SAND 6" DOWN AND 24" HORIZONTALLY BEYOND THE INSIDE WALLS OF POOL. #8 AWG BARE SOLID COPPER BONDING JUMPER SHALL BE INSTALLED IN AT LEAST FOUR (4) LOCATIONS AROUND PERIMETER OF THE POOL OR SPA. 1/4" TAP CON BOLTS 3" LONG @ (4) LOCATIONS 1/4" TAP CON BOLTS 1/4" TAP CON BOLTS 4" THICK CONCRETE SLAB EQUIPMEN- ANCHORAGE DETAII Ali Electrical work comply with the 20 11 National c is Code 40" 36" ,12" POOL SECTION Scale: nts POOLDESIGN.NET FLOOR SLOPE 1 ft. IN 14.5 ft 29' 47'-6" VGB APPROVED MAIN DRAIN GRATE SECURED IN PLACE SO TOOLS ARE REQUIRED FOR REMOVAL GRAVEL SUMP • ao CAP TILE EDGE IN CONTRASTING COLOR #3s @ 12" O/C BOTH WAYS BENCH DETAIL FLOOR SLOPE 1 ft. IN 10 ft HYDROSTATIC VALVE WITH WELLPOINT "J" BOX 12" MIN. ABOVE TRANSFORMER WAT LINE 5NMIN. ON 4' MIN. 0 ,NSI/APSP-7 INE TYPE SIZE FLOW (GPM) IFPS AIN DRAIN LINE 3" 130 5.9 RETURN LINE 2-1/2" 130 8.5 THERAPYJETS 2-1/2" 130 8.5 O 5. INLET FITTINGS SHALL BE 659 s.f RETURN LINE a. 51 3.33 INLETS (3) 1-1/2" DIRECTIONAL INLETS o_ (2) 12 V 5G LED - PENTAIR a DIRECTIONAL. FILTER CHECK z POOL (1) 32CDFL CHANNEL -AQUASTAR CONTROLLER PENTAIR EASYTOUCH SKIMMERS LU CHLORINE GENERATOR INTELLICHLOR IC -40 - PENTAIR SPA SPECIFICATIONS EXPERIENCE CAPABLE OF SUPPORTING A POOL AND DECK VALVE 7 ft. 0 in. WIDTH 7 ft. 0 in. THERAPY JETS 8 MAIN DRAINS (1) AQUASTAR CHANNEL 32CDFL101 Q o 6. PROVIDE A MIN. 18" OF HORIZONTAL OR HEATER (1) 400,000 BTU MASTER TEMP - PENTAIR zA (1) 1-1/2 HP PUMP (1) INTELLIFLO VARIABLE SPEED SHARED WITH POOL PAUL CHARETTE ARCHTTE E 2528 N 38 th Ave Hollywood FL 33 1 561.756 6094 w U AR - 0016279 z VERTICAL PIPE BETWEEN FILTER AND TREMBLAY RESIDENCE 2-1/2" SPA ¢ BOYNTON BEACH FL 33435 rr 11/22/2016 A 4OF4 Zv Q HEATER OR DEDICATED SUCTION AND :,'JETS--- ;= _ RETURN LINES SMALL BE INSTALLED TO ALLOW FOR FUTURE ADDIITIOtst OF SOLAR HEATING EQUIPMENT.`" " CV CV 40" 36" ,12" POOL SECTION Scale: nts POOLDESIGN.NET FLOOR SLOPE 1 ft. IN 14.5 ft 29' 47'-6" VGB APPROVED MAIN DRAIN GRATE SECURED IN PLACE SO TOOLS ARE REQUIRED FOR REMOVAL GRAVEL SUMP • ao CAP TILE EDGE IN CONTRASTING COLOR #3s @ 12" O/C BOTH WAYS BENCH DETAIL FLOOR SLOPE 1 ft. IN 10 ft HYDROSTATIC VALVE WITH WELLPOINT "J" BOX 12" MIN. ABOVE TRANSFORMER WAT LINE 5NMIN. ON 4' MIN. 0 ,NSI/APSP-7 INE TYPE SIZE FLOW (GPM) IFPS AIN DRAIN LINE 3" 130 5.9 RETURN LINE 2-1/2" 130 8.5 THERAPYJETS 2-1/2" 130 8.5 ANSI/APSP-15 LINE TYPE SIZE FLOW (GPM) FPS 19,70 AIN DRAIN LINE POOL 3" 51 2.31 659 s.f RETURN LINE 2-1/2" 51 3.33 PUMP PENTAIR INTELLIFLO 01101 URVE A 1725 51 GPM ALL N 19,70 URN OVER 6.43 HOUR -ILTER .375 GAL PER ST POOL SPECIFICATIONS LENGTH 47 ft. 6 in. WIDTH 22 ft. 0 in. MIN. DEPTH 3 ft. 0 in. MAX. DEPTH 5 ft. 0 in. AREA 659 s.f PERIMETER 126 ft GALLONS 19,700 INLETS (3) 1-1/2" DIRECTIONAL INLETS LIGHT(S) (2) 12 V 5G LED - PENTAIR PUMP (1) INTELLIFLO VS 011018 - PENTAIR FILTER PENTAIR CARTRIDGE CCP420 S.F. MAIN DRAINS POOL (1) 32CDFL CHANNEL -AQUASTAR CONTROLLER PENTAIR EASYTOUCH SKIMMERS (1) BERMUDA- PENTAIR CHLORINE GENERATOR INTELLICHLOR IC -40 - PENTAIR SPA SPECIFICATIONS EXPERIENCE CAPABLE OF SUPPORTING A POOL AND DECK LENGTH 7 ft. 0 in. WIDTH 7 ft. 0 in. THERAPY JETS 8 MAIN DRAINS (1) AQUASTAR CHANNEL 32CDFL101 LIGHT(S) (1) 12 V 5G LED - PENTAIR HEATER (1) 400,000 BTU MASTER TEMP - PENTAIR BLOWER (1) 1-1/2 HP PUMP (1) INTELLIFLO VARIABLE SPEED SHARED WITH POOL DESIGN PER FLORIDA BUILDING CODE 454.2 INCLUDING BUT NOT LIMITED TO 454.2.6.6 /R4101.6.1 ENTRAPMENT PROTECTION FOR SUCTION INLETS 454.2.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS DESIGN PER ANSI/ APSP - 7 2006 INCLUDING BUT NOT LIMITED TO SUCTION ENTRAPMENT AVOIDANCE REVISIONS GENERAL NOTES: 1) PLANS DESIGNED PER 2014 5th EDITION F.B.C. RESIDENTIAL CHAPTERS 42 & 45 and ANSI/NSPI 3, ANSI/NSPI 5, ANSI/APSP 7,ANSI/APSP/ICC 15 2) THE SITE HAS UNDISTURBED SAND, ROCK, SAND AND ROCK, WITH A MINIMUM BEARING VALUE OF 1500 PSF. THE FOLLOWING IS DETERMINED BY RATIONAL ANALYSIS, 3) SOIL CONDITIONS IN THIS AREA HAVE BEEN BY PAST EXPERIENCE CAPABLE OF SUPPORTING A POOL AND DECK OF SIMILAR SIZE AND DEPTH. IF CONDITIONS DIFFER FROM CONDITIONS SPECIFIED ABOVE, THIS ENGINEER SHALL BE NOTIFIED PRIOR TO FURTHER CONSTRUCTION OF THIS PROJECT. 4) ALL CONCRETE SHALL CONFORM TO A.C.1318-11. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI FOR PNEUMATICALLY PLACED CONCRETE (GUNITE/SHOTCRETE) ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BARS OR 5) NEW BILLET STEEL CONFORMING TO A.T.S.M.-15. STEEL SHALL BE BENT, LAPPED, AND PLACED IN ACCORDANCE WITH A.C.I. STANDARDS AND SPECIFICATIONS. PIPING: ALL POOL PIPING SHALL BEAR THE N.S.F.-PW SEAL OF APPROVAL 6) AND SHALL BE SCHEDULE 40 P.V.C. MIN. POOL PIPING TO COMPLY WITH F.B.0 . POOL EQUIPMENT TO APPLY TO F.B.C. i I 7) WATER SUPPLY AND DISPOSAL SHALL BE SO ARRANGED THAT THERE IS NO i CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM AND SHALL MEET ALL REQUIREMENTS 1N F.B.C. EQUIPOTENTIAL BONDING GRID SHALL BE INSTALLED PER 2011 NEC SECTION 8) 680.26(C) PAUL CHARETTE ARCHTTE E 2528 N 38 th Ave Hollywood FL 33 1 561.756 6094 PAUL CHARETTE AR - 0016279 DETAILS TITLE TREMBLAY RESIDENCE DESCRIPTION 3010 PINE TREE LN, BOYNTON BEACH FL 33435 DATE 11/22/2016 PAGE 4OF4