Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
CERT OF OCCU
CO CHECKLIST Permit: 2019-2946 Address: 102 NE 7T" AVE BLDG 1 Date: 10/29/2020 PCN: 08434521100010010 Build Elect Plumbing Mechanical Site Lighting Irrigation 10/28/2020 10/19/2020 10/07/2020 10/19/2020 Fire Low Voltage Gas Hood Paving Landscaping 10/28/2020 10/19/2020 Roof Fire Alarm Fire Sprinkler Fire Supp Drainage ENGN Final 06/10/2020 10/27/2020 10/27/2020 Req Sat NOTES Outstanding X Revisions Outstanding X Permits • Tie-in/ Form X Board Survey �( Final Survey X x Soil Treatment X Certificate K Soil Density Rep X / Piling Cert • Insulation X Certificate Elevation Certificate X Approved By:•9w O\�k, U� Threshold/ X Reference Statues 553.791(11) & 533.79(7)(a) Spec Insp Cert Blower Door X Required if application date is after 7/1/2017 Test Interim Fire X Rescue Fees Public Art Fee Zoning Final Approved By: CO Approved By: C:\Users\RemyS\Desktop\Intake Helpful Information\CO Checklist(New)\CO Checklist(NEW).doc(10/05, 1/06,3/06,8/08, 12/08) 9/18/2020 Ocean Breese Apartments CO Request-Alex Vega Ocean Breese Apartments CO Request Remy, Svon <RemyS@bbfl.us> :::::;:::::centennialmgt.co ; 9 1 attachment(44 KB) CO Checklist(NEW).doc; • / 91 Hey Alex, 94- 4. This is what I want to talk to you about... Since you are almost done with the job I know you guys are going to request some Certificate of Occupancy. I am going to send our checklist for a CO. Which is what my Building Official is looking for. Now here where the issue is going to start happening. All the inspections Documents we are going to need them for each building. • Tie-in/form Board- urvey'I • Final Survey— • Soil Treatment Certificate --(Zr • Soil Density Report--Me • Insulation Certificate— • Elevation Certificate( Before and After Const ction. With picture and in color) -21 • Threshold/SpecialIns✓pector Certificate — • Blower Door Test—E Now I know a lot of these documents was on site and CAP may have picked them up. But we do not have anything. Call me if your confused or need some help. G`t Y o Svon Remy Application Technician � � Development, Development Services Mailing Address: P.O. Box 310 I Boynton Beach, Florida 33425 i Physical Address: 100 E. Ocean Ave. I Boynton Beach, Florida 33435 o' , 4 ` 561-742-6283 Tp 0 RemyS@bbfl.us I ® boynton-beach.org/ ft100YearsintheMaking Follow us on in Please be advised that Florida has a broad public records law and all correspondence to me via email may be subject to disclosure.Under Florida records law, email addresses are public records. Therefore, your e-mail communication and your e- mail address may be subject to public disclosure. haps://mail.centennialmgt.com/owa/#viewmodel=ReadMessagellem8ItemID=AAMkADIIYjM3NzJkLW01 YmYW DU5Yy04NZI0LTO1 OWMzNzEIYjIxYg... 1/2 er,/..?" C ‘-‘ icnn • • . ttle D/L/ 1 -boo-DILIGENT TERM/TESERI/ICES • ♦ MyDiligent.com CALL DILIGENT FOR State License JB228623 Building together, Growing Together • CONCRETE WASHOUT! Notice of Preventative Treatment for Termites (as required by Florida Building Code 2326.5 and Broward County Chapter FBC 105.2.2) / 1 n e ,/ SERVICE ORDER NUMBER 1 S2)Oct 3 SERVICE DATE 2•22..1.1 ' 1v TIME• , 00 c NI WEATHER CONDITIONS C L 1 DEVELOPMENT NAME(PROJECT) CO RACTOS NAME CONTACT PERSON bC.et.h brat26 CI 54- R' -' Ylb ''Cy S ?JAi �6,e,r.S - 06 Scot r STRUCTURE16 bADDRES�(LOT/ itte Ave ( beyin'ivn ITY,STATE,c,ci-,, FL { 3P CODE 3 3 5 COUNTY CONTACT PHONE NUMBER /l''11 NOTES C.• -7%0- iso-3G/5 (DED -LL. 1 • TREATMENT TYPE/AREA 0 FLOATING ®MONOLITHIC 0 PATIO 0 GARAGE 0 DRIVEWAY 0 STEM WALL 0 ADDITION 0 CUTOUTS 0 FOOTERS U FRONT ENTRY 0 EXTERIOR PERIMETER FOR RENEWAL 0 OTHER TREATMENT� TYPE `TR� MP 8 TREAT 0 TREAT ONLY 0 FINAL . 0 RETREAT 0 BORA CARE TREATMENT 0 TERMITE BAIT STATION PRODUCT OMINION 0 ADONIS 2F 0 PREMISE O DEMON TC ❑TERMIDOR 0 BORACARE 0 OTHER ACTIVE INGREDIENT Z,N`Z� CONCENTRATION ... 0.05% 0.06% Ayt% 0.12% 0.25% 0OTHER GALLONS APPLIED SLSL ••tAITESFj�; N • • ` / .•4' •• •N p•0 A),..%., 1•0�• SQUARE FOOTAGE 1211 )-0 LINEAR FOOTAGE - ;V,� •0 9 a�• ��,:' • �:/ 41.t. 1 5S�QUARE FOOTAGE VERIFIED reA �`t' " I ISOES 0 NO U MEASURED OR VERIFIED PER PLANS ` OP ( V \ .•._O R ' •.' , JOB READY CONDITIONS MET _ `• ,, • . ' S .NO . DETAILS '' ] � III SAFETY CONDITIONS 61,0-0 Cly As per 2326.5 FBC-If soil chemical barrier method for termite prevention is used.Final exterior treatment shall be completed prior to final building approval. Certificate of Compliance:The building has received a complete treatment for the prevention of subterranean termites.Treatment is in accordance with rules and laws established by the Florida Department of Agriculture and Consumer Services.(Per the Florida Building Code.) If this notice is for the final exterior treatment,initial and date this line (TERMITE MONITOR INSTALLED 0 YES 0 NO) FINAL STICKER 0 ELECTRICAL PANEL 0 WATER HEATER . OTHER Payment Terms: Customer's payment in full is due at time of initial service.Customer agrees that a finance charge in the amount of 18%per annum will be assessed on all unpaid balances that are not satisf:d by the due date. In the event a collection process becomes necessary to recover an unpaid balance the following fees will be assessed inclu.• .ut not limited to collection service fee,attorney's fee,finance charges and non-sufficient funds payment fe-el. Cul / stomer will be responsible M.p. g all cost,asso ',ted with a. collection process. L. Date Applicator(Di gej'rvIces J . 2_7 2.6 ,i Date Customer''`'/ *" Owner or Agent) Corporate 3500 NW Boca Raton Blvd. I Suite 714 I Boca Raton, Florida 33431 I 1-800-DILIGENT I mydiligent.com Professional Insulators of South Florida FTC Insulation Installation Certificate To: Palm Beach County Date: July 22,2020 Re: Building 1 Address: 701 N Seacrest Blvd Project: Ocean Breeze East The undersigned hereby certifies that insulation has been installed in the above described property as follows: 1. Exterior CBS walls have been insulated with: Spray-on Cellulose Thickness in inches: Fiberglass Blankets Manufacturer: Fi-Foil VR Plus Shield • Rock Wool Blankets Density: X Aluminum Foil R-Value: R-7 Rigid Board Polystyrene Other 2. Underside of Roof Deck have been insulated with: Spray-on Cellulose Thickness in inches: 13.8 X Fiberglass Blown Manufacturer: Johns Manville Climate Pro Rock Wool Blankets Density: Aluminum Foil R-Value: R-38 Polyurethane Open Cell SPF Applied Directly to Open Cell SPF insulated with: Spray-on Cellulose Thickness in inches: • Fiberglass Blankets Manufacturer: Ignition Barrier Density: Fiberglass Blown R-Value: • Cellulose Loose Fill Open Cell SPF 3. Perimeter kneewalls have been insulated with: Fiberglass Blankets Thickness in inches: Fiberglass Loose Fill Manufacturer: Rock Wool Density: Fiberglass Blown R-Value: Cellulose Loose Fill Open Cell SPF 4. Garage/House and Garage under living area walls have been insulated with: Fiberglass Blankets been insulated with: Rock Wool Thickness in inches: Polyurethane Manufacturer: Spray-on Cellulose Density: Open Cell SPF R-Value: 5. The following have been insulated: • RS CONSTRUCTION OF DADE,INC PORAre•Om General Contract/Builder :,: see tea • • SEAL •= t' 2009 :$ CGC1527092 Lop. : O Competency# it, rim Professional Insulators of South Florida, Inc. ''r aiC At,,v� Insulation Contractor By: By: 1: 11 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING March 2, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 N. Project: Ocean Breeze Ct 100 NE T" Avenue, Boynton Beach, FL w N CO Permit #: 19-00002946 (DID m Reference: Buiillding 1 SOG, foundation, and fill cells 1020 0 Dear Builtl" ing Official: 1030 E This is to certify that this office!saobseQ1d_t11e-a-b!7eference reinforcement and it is in accord ancence t approved drawings by ARA Engineering, INC. Ma No exceptions.taken.cn ■ c't 1111 ©1.-1 Best Regards, 111111 , 00011'1111110f/ ```\,IC1SII Milt j'' i,QJP'''‘,tENSF' �l, c/ Ei C"‘cr..- C. N ••A/4:c :;P:..41-H421 17;11... .7.- .....\ v E * n /ST ��0 o _ ca �0,�'. STATE OF •.' Q7�: �CCss/O....• !\ �� L ��Li ��/0'9,/ONAL,ENG`. Eduardo Roman PE.,SI. PRESIDENT PE 71118 II- ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING March 19, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL CV N Permit#: 19-00002946 en N. Reference: Building 1 2 d FloortSlab Steel Reinforcemenli O-3D vi m Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in o accordance'of4he'approved'drawings by the City of BoyntomBeach. o PI sNo exceptions•taken. me . ._. , In d Best Regards, ■MUM ,t, 00eAriirldy pR, . N %4. Qr \--‘.. :Rpif % ` 0111111 03 " 1G • .� O ce CD :: * .? ,i; _.e , 1118 NO. p11J� _ . ' -.W /_ 0 ec -AQo STATE OF .[Lei 2 Vs. F OR 4. W �'"�'itiONAL IS.'oS '/,`,SSIONAL v-\`\ Eduardo Roman PE., SI. PRESIDENT PE 71118 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 10, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze N. 100 NE 7th Avenue, Boynton Beach, FL Co(N Permit#: 19-00002946 taftimi�e. Reference: Building 1 3rd FloordSla'b�Steel Reinforcement' -r,090 N Dear Building Official: E This is to certify that this office has observed'the above reference reinforcement and it is in o accordance,of•the•approved"drawings by the City of Boyntons each. ch d No excep'tionsitaken. ■ ■� • Best Regards, ■� 0 \ullll,, A ?DO A. , JpfiO...•..Rp . ,,y p A. ''o. O • 0C, N •'� :r.p,FL�z::.:R9.y7.:4, * % • . C 4QEEittrutivio. o 1:73 _ y ' .71118 ' .�.. = Q -• STATE OF !V . • 741 y/ a(2' t Cu UJ '''''lllllt\\\\ Eduardo Roman PE., SI. PRESIDENT PE 71118 , INSPECTION LOG ARA Engineering,INC Lic. No 71118 Eduardo Roman Inspector: PE.,SI Building City of Boynton Beach Building Department-3301 Official Quantum Blvd-Boynton Beach, FL,33426 General RS Construction Contractor: • Ocean Breeze-100 NE 7th Ave, Boynton Beach, - Project Florida Permit ft 19-00002946 PCN 08-43-45-21-10-001-0010 Reference: Building ft 1 Inspection log detail Inspection Date Inspection IS Type of Inspection Comments PASSED Approving Signature 3/2/2020 1010 Footer 3/2/2020 1020 Foundation 3/2/2020 1030 506 steal reinforcement 3/17/2020 1100 First Floor=Vertical Steel Column Reinforcemnt J CI( rf 3/17/2020 1110 First Floor=fill cell Inspection 73/19/2020 1030 Second Floor: Slab steal reinforcement 3/24/2020 1100 Second Floor=Vertical Steel Column Reinforcemnt Filled Cell 3/24/2020 1110 Second Floor=fill cell Inspection 4/10/2020 1030 Thrid Floor: Slab steal reinforcement 9 .s 4/14/2020 1100 Thrid Floor=Vertical Steel Column 7 -6. Reinforcemnt Filled Cell 4/14/2020 1110 Thrid Floor=fill cell Inspection 1I i I 4/14/2020 Bond Beam 4/30/2020 1400 Roof Truss erection . ft 5/12/2020 1450 Roof Sheathing , 5/l3/2020 1460 Roof Engineering Bracing 7 a r 7/anda 1475 Window Buck and letter / 1 A ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING March 2, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze a 100 NE 7'" Avenue, Boynton Beach, FL 0 N Permit #: 19-00002946 4 ib to Lo m Reference: Building 1 SOG, foundation, and fill cells j# 10 2a Dear Building Official: k.)2 E This is to certify that this office has observed the above reference reinforcement and it is in accordance to the approved drawings by ARA Engineering, INC. 0 m No exceptions taken. 0 Best Regards, •0 \ ,Ill � -a �` O �i, 0\0101111i/oil :OJ?R.�.N•Roq��'; \' %tRO '% * :' / Imo'(y,�I jNO. 1 'cc O� STATE OF AC. Pi �� TAN iS C�C7 : A\ ''• .ELORIDP.' �C ' C 'f .,� NAL IE c'� .////73/0 \\\\ Eduardo Roman PE.,SI. PRESIDENT PE 71118 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING March 19, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7" Avenue, Boynton Beach, FL N N Permit#: 19-00002946 co Reference: Building 1 2nd Floor Slab Steel Reinforcement'/030 Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in accordance of the approved drawings by the City of Boynton Beach. S No exceptions taken. N cn Best Regards, �1�11111111.r r \ P \11111u \. ONR0,l9 \ \` to,r �� �pO A. R0� \`\ . 2 CoGENS a) * •. No. / No 111 * _ o in STATE OF 13 ';�er,.'•.F4ORIO�.'• `��F o � �rhrlAL r-,0‘ ONA1 \ Eduardo Roman PE., SI. PRESIDENT PE 71118 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 10, 2020 Building Official ' City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N Q Permit#: 19-00002946 4j 10 30 co Reference: Building 1 3'd Floor Slab Steel Reinforcement 4 in co Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in • accordance of the approved drawings by the City of Boynton Beach. c No exceptions taken. d C 0) • Best Regards, (173 ``�Itllllttiiri. \``tt II IIII _no A �O •.•' A1C N '•.-`92% C.%‘ �0 .• �10ENSF•.% * . .1. twyolio. 1 - 0 o ��Q�•. STATE OF '..off.. ' /..f TE 1(/�� - -.• .t ORM a..'. \C\� [ •S �G , cflrc0� �/IS/ONAL E%\‘ /.,‘91°N. °NAL °\`\ W ''III1111 {1\ I//IIIA W Eduardo Roman PE., SI. PRESIDENT PE 71118 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING March 17, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N N Permit#: 19-00002946 Reference: Building 1 HSS Column 151 Floor "# X100 N Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in accordance of the approved drawings by the City of Boynton Beach. No exceptions taken. • d C cp 0) Best Regards, clo \\�111iulrf , ctp0 a• RQjk ''•, Q..• 9: \,1C N :94, '`�V: a * 71118 //�/7 / l / /,/li _ CC Z r ; �' STATE OF \� cc o 'O'� STATE OOR1D� (V "ice //jS/10 � sron A� \\ -a LONAL 'coo Eduardo Roman PE., SI. PRESIDENT PE 71118 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING March 24, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N CO Permit#: 19-00002946 In Reference: Building 1 HSS Column 2nd Floor # )100 Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in accordance of the approved drawings by the City of Boynton Beach. ch No exceptions taken. a)C Best Regards, \ ��tlrrrrrr " n Illy, 10, I.,. Rp -0 412..•' LIC N ''.►, � Q L\CENSE * : NoE .* � _ / 0. 7111 cc STATE OF : (V � T ' .v •AtOR10�' \ � NirrtigIn2 .44/ '. ORIDP•. ' \co G �SSiONAL /USN,. \ w '�rlrl n llt� ` /'rrllllll��� Eduardo Roman PE., SI. PRESIDENT PE 71118 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 14, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze • 100 NE 7th Avenue, Boynton Beach, FL N N Permit#: 19-00002946 Reference: Building 1 HSS Column rd Floor JI(oo L0 N Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in accordance of the approved drawings by the City of Boynton Beach. No exceptions taken. d C, p Best Regards, ca 'o \```111111111,,�,A Ws, N: R,-, '.,� X000 A.to No. I • - ado. 7111/C Eitysti E o // / o2".�I5f � % O STATE OF •' (V` j i 1 y � o i�(C` .F(ORIOP. '• \ : -. �^ S A E OF% i\ i0 E ;ass " / Nc ; w ',�111NAL ` 1 //, ;ONAL E \\\ Eduardo Roman PE, SI. PRESIDENT PE 71118 • ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS.FORENSIC ENGINEERING April 14, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N (0 V Permit #: 19-00002946 Reference: Building 1 Bond Beam a-}I'UO In Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in accordance of the approved drawings by the City of Boynton Beach. No exceptions taken. Best Regards, kotilifolfi go0AR , m . Q yif_. �tt� llll, , kr/ 41C N/ . --'.�7.9 � . •\ �`\ QQ A. RQ �'•/ii * _ ;�F� �C NSF '^� • . ..711 7111 E • O . STATE OF ((/ .\ //7M 20.�F(OR �..' G\_$‘ E.TATE OF EN\`� ' Mill I • \\ Eduardo Roman PE., SI. PRESIDENT PE 71118 • ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING March 17, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7'" Avenue, Boynton Beach, FL N V Permit#: 19-00002946 Reference: Building 1 Fill Cells 15' Floor * 1110 Dear Building-Official: E This is to certify that this office has observed the above reference reinforcement and it is in accordance of the approved drawings by the City of Boynton Beach. No exceptions taken. a, 0) CD, Best Regards, CD \11111lu/o p0 A. E ,,\.000W/oft 00 A ��11 O PR ......:Rn '' JP ' CENs•E '• ?y 0 Eicytte 04 0.7111 Na. 1 ' E o , 0 STATE OF -o , • <ORIO ..•• \�s` '' w ',to.' ENG` '///p./ONAL 111111111\\ 11111111111\\\ Eduardo Roman PE., SI. PRESIDENT PE 71118 • ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING March 24, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N V N Permit#: 19-00002946 Reference: Building 1 Fill Cells 2nd Floor 0.11(0 Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in accordance of the approved drawings by the City of Boynton Beach. C No exceptions taken. a) - Best Regards, ``\1111111111/// \\`IIIIII !„r noA. R ' ,, 0 A JP .......0 \\ FlO• .....RU y7 tvirdio. y ato." 711 E STATE OFI� FcoRIOr.• ? �l RI JP.• o w /, NAL11 ` ` CONAL r �'�IIIIIII\1\ Eduardo Roman PE., SI. PRESIDENT PE 71118 • 1111 CC mon • • ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 14, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7'" Avenue, Boynton Beach, FL Permit#: 19-00002946 Reference: Building 1 Fill Cells 3rd Floor WD ° Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in accordance of the approved drawings by the City of Boynton Beach. m No exceptions taken. Best Regards, r op../ Rp ''%, ,,c�00 A. ,-, ' oc. N '.!L/9 � �., •‘,GENSF'.: *• No. .71118/; co r — Q STATE OF •' (( � , •// STAT .. z S,ONAL S', w / `'ONAL • 'VIII I ,II`\ Eduardo Roman PE., SI. PRESIDENT PE 71118 • IA ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 30, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 71h Avenue, Boynton Beach, FL N V CO Permit#: 19-00002946 Reference: Building 1 Roof Truss Erection 4/- INbb Dear Building Official: E This is to certify that this office has observed the truss erection and it is in accordance of the g approved drawings by the City of Boynton Beach. •C No exceptions taken. a) Best Regards, X111111111!/ ,1 X1111111)11 RDO 'o (<7.. %SG N • - •. � LICENS • Q * ' No. 7 _ No. ?i o - Off . STATE OF •' C(7�� v, • � • ♦�' 111111111\` �111111111�� V . S '' S1ONAL ?``♦ ONNG� `/'' AE � w Eduardo Roman PE., SI. PRESIDENT . PE 71118 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 23, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N N Permit#: 19-00002946 Reference: Building 1 Roof Engineering 3 I goo m Dear Building Official: E This is to certify that this office has observed the roof engineering and it is in accordance of the approved drawings by the City of Boynton Beach. No exceptions taken. a C Best Regards, • o) 000%111;0i,, N \\\\,\r•�?..A:Ro 'O.f `,,, II I I I I;I11 . kr. J7 kr. �c N q2 JI^R�� A:ROAI'% Na. 1 Qi c * ah4o. 71 •• T� E �� ', �- o Qom•. STATE OF ((/` Y-51770 D '^.'�•k� � cA\S••. .4ORM a.•' G\?.ca .• OF kc- w /' IS%ONAL1�?\• \\ > ��C . LORIOP..•'• \��\ /„'ONAL ENG\ IIII11�ti` Eduardo Roman PE., SI. PRESIDENT PE 71118 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING May 12, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL Permit#: 19-00002946 Reference: Building 1 Roof Sheathing ' 1450 N Dear Building Official: e This is to certify that this office has observed the roof sheathing and it is in accordance of the approved drawings by the City of Boynton Beach. No exceptions taken. a Best Regards, \�\1111111 II/! • pR�....: Rp ,, \\,,,111111,,, O • 'IC N •••. f 0)0 A. R '%, * ' •J ./\CENSE• Ai - 7111 cc O ' STATE OF •• (U(l/` - /C�/ �.0 . f o i (t 0. !�<OR1D•• •JO\,• ^ .• /STATE OF .' �/ � 1 r/1 111111\ //iS/ONAL C, 'rrrll 11111\\\ Eduardo Roman PE., SI. PRESIDENT PE 71118 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING May 20, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL Permit#: 19-00002946 �� Reference: Building 1 Window and door bucks 1� °' Dear Building Official: This is to certify that this office has observed the installation of the window and door bucks and • it is in accordance of the approved drawings by the City of Boynton Beach. No exceptions taken. • Best Regards, - `��Iltullii ` ` Jc&pO A. R� �. d �;(VO '•.`•,C N/ i - c *` oo : Q • om•, STATE OF • IQ co ', S'1ONAL t'\''• W '1111111111 I • Eduardo Roman PE., SI. PRESIDENT PE 71118 . . AMERICAN TESTING MATERIALS ENGINEERING, LLC. "testing Laboratories-Engineering Inspection Services-Chemist-Drilling-Environmental Services 1950 West 84th Street,Hialeah,Flonda 33014-Phone:305-648-1888 Fax.3 1187 0 i Field Density Test of Compacted Soils ASTM D-5195 Client : ddress: r irojea:ectone No: . ?man Breeze,LLC Order It 20-0228 7735 NW 146th Street Suite I 306,Miami Lakes, FL 33018 Date: 2/28/2020 Ocean Breeze East Apartments-Building 1 703 N Seaaest Blvd.,Boynton Beach,FL 33435 Alex 305 216 1490 - , Gauge SIN: 23082 . 1 ....... , Test Number Location(s) 1 Final Lift Buikfing Pad(See Plan Attached) 2 Final Lift Building Pad(See Plan Affached) 3 Final Lift,Building Pad(See Plan Attached) 4 ?mai Lift Building Pad(See Plan Attached) 5 Final L.M.Building Pad(See Plan Attached) of Metals* Brown sand with some stones -. - . rescriPnwi FS I _ Backfin I I Subgrade I x I Elam Rock _ I _ ,, Tested By: IJM . _ . _ _ . 4 Test Number . _ - --1 2 3 5 Depth(In) 12° ir 1? 1? 12- Reid Density LB/Cu Ft Wry Density) 106.3 105.9 106.8 107.3 107.1 AfOiStUra Contents . ' ' 8.0 7.5 ., - 6.9' 6.4 -- 6.0 Maximum Density in the Reid(%) 99.1 98.7 99.5 100.0 99.8 Connection Requirement by Specs(%) 93.0 95.0 95.0 95.0 95.0 100%Maximum Density(Iat12)-AASIITO TIEN 107.3 107.3 107.3 107.3 _ 107.3 Optimum Moisten(%) 11.4 11.4 11.4 11.4 11.4 Status - PASS PASS PASS PASS PASS Remarks: . . . Typed By alt Respectfully ,subrittnid by, ..„•;:'-'t'ES 11 if. :'... .... • ..S•'-'1.•••"••••.. OA . --:: - \Nk 11.1111V' '"--- , #9-P1ri cil ci i - ...-- i J-). 514f.1•1 .. F: Watteem Quadri,P.E.0 51481 :II • .,. .4.I• • t4. -:. AMERICAN TESTING MATERIALS ... • ,. • r. ENGINEERING, LLC. I MATI'of :" - 1: , . •:, ,,,,,....... .31110'...,-,,ie letotculdiansrty same cordtions In the tealaeb Wye Mideetire 0, ,," tors Saari encountered on the tested treettotreportaa on our Denelly Tut Teton Itatteida Enalneerles'US It rota to hett ' 12- "..4.0" Asa muftisi prateceon tact**the pubic end aureaa at mordere tarnittect in the=Partial property of dents end eultorthelian fat putfleation of atetementa cenCitelone or Wet tan=cola ie ream& • AMERICAN TESTING MATERIALS ENGINEERING, LLC. (41!� Testing IBDOretones•Engineering Inspection Services-Chemist-Drilling-Environmental Services �l 1550 West 84th Street,Hialeah,Florida 33014-Phone:305-648-1888 Fer305-646-1887 36, Field Density Test of Compacted Soils ASTM D-5195 Client Otwan&sena,LLC Order 0: 20-0228 Address: 7735 NW 148th Street Suite 0 306,Miami Lakes, FL 33016 Date: 22812020 Pigott Ocean Breeze East Apartments-Building 1 Gauge SIN: 23082 Address: 703 N Seaaest Blvd.,Boynton Beach,FL 33435 1 Phone No: Alex 305 2181490 Ares: - -- - - --- - - -- - - - ! I Teat Number Location(s) 6 Final Lift,Building Pad(See Plan Attached) 7 Final Lift Building Pad(See Plan Attached) 8 Anal Lift,Budding Pad(See Plan Attached) 9 Anal Lilt Building Pad(See Plan Attached) 10 Final Lift,Building Pad(See Plan Attached) of Matariat Brown sand with some stones rescr:17" I BaehftY I I Subgrade I _ I Base Rork I Tested By: !JM Test Number 6 7 8 9 10 Depth(In) 12' 12' 12" 12' 12' Feld Density L&Cu Ft(Dry Density) 108.0 1055 106.9 1061 107.5 Moisture Contents &3 7.5 7.1 ' 6.9 8.0 Maximum Density in the Reid(7q 100.7 98.3 99.6 98.9 100.2 Compaction Requirement by Specs 04 95.0 95.0 95.0 95.0 95.0 100%Maximum Density(Lab)-AASNTO T180 107.3 107.3 107.3 _ 107.3 107.3 Optimum erre(76) 11.4 11.4 11.4 11.4 11.4 Status _ - - PASS PASS PASS PASS PASS Remarks: Typed By el -S.' -,•:Vic,'- •r: Respectfully submitted by. 4 :N - Ld f. _ aseem Quadri.P.E.A 51481 'h'• .TAT, r _ &.MERICAN TESTING MATERIALS ENGINEERING, LLG frsp •....... •;..'.. �`(�t�r�l \•: •-. s: es �Y eubsdi Ca s in em SIMS lsdhm>tl es found arnbm+lemrtloaa erw,ursaea on the tested loceeW yeporeeC on eat Dentist rest. I testing Warts Engineering,LLC m nm to be hen responsible. Ssafaunal ire&tlenesdant.eewhile and ours*esseworts ars orb as the rarlf1Snbalown ofdents.and ethorinfanfar publication of at once,mnclualons or Si.font our reports Is raeevam F- - • r ' ' ! -pal 1 1 ht '-1 V.i ` 1 H 1 1 16l 1 '� � A __.^11:.1 yr 9 -4_4- �1 � R1� o I . I , 9• ' I,i_SI'r -, - • .-. L a . I1.. il- - ---:ii_._,. _ \ ., , __., .0.-, 1 allril - n:.:: yi i 3 o 41 i- all . - _ _ i : ,it; _r9i i _- - _, . I llE �r``� - �:1 Lail 1 I^,n I i - - „:„....j•- ___.. ..�+.: ten � �r•_ . ,t_► , l� j m,:,,_ p 3 _ • k p ; is a • ; Vii- i . n -- 'Ill , f(-1� • fF It) r. 11 n 1- 1. ' n Y. `' - _ , `+ `_ 1 r - - 1 7Y » 3 I III f -\ , ` -�. ' E - R ( lilt f •- ' 7`- 's ie •� ,� 1. I -.mitissd'•._ --t� e I : 4I I I.-� I p,' '1 t i ii 7. _.� , • � i. vIll i ! :Iiii 'i 1L; ItuM; iiiiiiiiiilri 6 i, 1 ,,'.64 ,:1 , SERVICES Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2946 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 102 NE 7th Avenue Bldg: 1 Unit: 103 SOFT: 709 City: Boynton Beach State: FL Zip: 33435 Alr Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. 0 PERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form 11405-2017-Energy Calc(Performance)or 8406.2017(ERO: ] 3 5-6 x 60 + 6,310 = 2, 38 MrrhodfOLialndatingbuilding volumP' CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans [PASS ❑FAIL 0 Code software calculated When ACH(50)is less than 3,Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either IndMduals as defined in Section 553.993(5)or(7),Florida Statues,or Individuals licensed as set forth in Section 489.105(3)(f),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterlor windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the Intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust.intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.intenor doors,if installed at the time of the test,shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. S.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: 10/12/2020 r Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute aaside, Envelope Leakage Test Report (Blower Door Test) F' `+ iCE Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2946 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments .Lot: Blk: Address: 102 NE 7th Avenue Bldg: 1 Unit: 104 SQ/FT: 709 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. . ACH(50)specified on Form R405-2017-EnergyCalc(Performance)or R406-2017(ERI): , .3 6'9 x 60 + 6,310 = .3.69 Method for calculating building volume CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS F1FAIL O Code software calculated ❑When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted In accordance with ANSURE$NET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth In Section 489.105(3j(f),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall he performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the Intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond Intended infiltration control measures. 3.Interior doors,if Installed at the time of the test,shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,If Installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. • Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: �,�/w,.Zg Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority:BPI - Building Performance Institute ;seaside Envelope Leakage Test Report (Blower Door Test) SERvirEs Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2946 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 102 NE 7th Avenue BIdg: 1 Unit: 105 SQ/FT: 709 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. / ACH(50)specified on Form R405-2017-Energy Calc �(Performance)or R406-2017(ERI):I 7 Z x 60 + 6x310 = 7, &3 Method for ialculatinrbuildinvyoWme CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS ❑FAIL O Code software calculated 0 When ACH(50)is less than 3,Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted In accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers Including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond Intended infiltration control measures. 3.Interlor doors,If Installed at the time of the test shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,If Installed at the time of the test shall be turned off. 65upply and return registers,If Installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: -74 \ Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute 4easide Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2946 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 102 NE 7th Avenue Bldg: 1 Unit: 106 SQ/FT: 709 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405.2017-Energy Caic(Performance)or R406-2017(ERp:I 1 3 Z 4 x 60 + 6,310 = 3. 0 Q Method for telydaringb ildin vohimr• CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS ❑FAIL O Code software calculated When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other Infiltration control measures. 2.Dampers Including exhaust intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test shall be turned off. 6.Supply and retum registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: 6foi/ Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority:BPI - Building Performance Institute Nosside Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2946 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 102 NE 7th Avenue Bldg: 1 Unit: 107 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form 11405-2017-Energy Calc(Performance)or 12406.2017(ERO:I I 51z E x 60 + 8,152 = 3. j.c Merhndfor cafudating building volumP• CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans IXIPASS [1FAIL 0 Code software calculated 0 When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined in Section 553.993(5)or(7),Florida Statues,or Individuals licensed as set forth in Section 489.105(3)(f),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the Intended weatherstripping or other Infiltration control measures. 2.Dampers Including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond Intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company • Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: ii d Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute Qj;aside Envelope Leakage Test Report (Blower Door Test) IC Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach I Permit#: 19-2946 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: • Address: 102 NE 7th Avenue Bldg: 1 Unit: 108 SOFT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing result must meet either the Performance,Prescriptive,or ERI Method PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form 8405-2017-Energy Calc(Performance)or R406-2017(ERI): 4112Z x 60 + 8,152 = 3. /0 Method fntcalculatingbuildincvolume• CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans ISIPASS FAIL O Code software calculated C When ACH(50)is less than 3, Mechanical Ventilation 0 Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues,or Individuals licensed as set forth in Section 489.105(3)(f),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterlor windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.interior doors,If installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,If installed at the time of the test,shall be turned off. 6.Supply and return registers,if Installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. • Signature of Tester: c--77//‘(75/0-- -eDate of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute :/easide Envelope Leakage Test Report (Blower Door Test) Na E R V I C E S Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2946 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 102 NE 7th Avenue Bldg: 1 Unit: 109 SO/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0,2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. .p ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI): 54 3 x 60 + 8,152 = '54 2 9 Method for cal Matin bulldtngvoliImr' CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans n PASS (FAIL O Code software calculated Ej When ACH(50)is less than 3,Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted In accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3Hf),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers Including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond Intended infiltration control measures. 3.Interlor doors,if installed at the time of the test,shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,If installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according gttootthe compliance method selected above. Signature of Tester: �� / - Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto • �J License/Certification #: 5010864 Issuing Authority:BPI - Building Performance Institute aside Envelope Leakage Test Report (Blower Door Test) SERVICES Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2946 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 102 NE 7th Avenue Bldg: 1 Unit: 110 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI): 1 Lc?2— 9 x 60 + 8,152 = 3, / i Methodfncsalculating_huildingvolumr' CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS F1FAIL O Code software calculated ['When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other Infiltration control measures. 2.Dampers Including exhaust,Intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interlor doors,If installed at the time of the test,shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company • Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: r-a( +.� Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto111ll1 License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute ;/'aside Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2946 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 102 NE 7th Avenue Bldg: 1 Unit: 111 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. /ACH(SO)specked on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI):I 1 SIMx 60 + 8,152 (L= / Method for LdlcidatinghuilrlingvnhIMP' CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS FAIL O Code software calculated ❑When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterlor windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according toot the compliance �method }selected above. Signature of Tester: —7s / �_ Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority:BPI - Building Performance Institute Qieaside Envelope Leakage Test Report (Blower Door Test) vicEs Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2946 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 102 NE 7th Avenue Bldg: 1 Unit: 112 SO/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. 7ACH(50)specified on Form R405.2017-Energy Calc(Performance)or R406-2017(ERI):1 ] V9 x 60 + 8,152 = .3. b J MPrhnd calculatin ,b ui vobimP' CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS ❑FAIL O Code software.calculated ❑When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 4E19.105(3)(t),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the Intended weatherstripping or other Infiltration control measures. 2.Dampers including exhaust.intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond Intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if Installed at the time of the test shall be turned off. 6Supply and return registers,if installed at the time of the test shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: _off Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute aside Envelope Leakage Test Report (Blower Door Test) R v I c E ss Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2946 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 102 NE 7th Avenue Bldg: 1 Unit: 201 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an alr leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI):I ] 5.-- / x 60 + 8,152 = 3. -72 2 Method for calculatin buiidinvolume• CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS l 1FAIL O Code software calculated ['When ACH(50)is less than 3,Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted In accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the Intended weatherstripping or other infiltration control measures. 2.Dampers Including exhaust,Intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.interior doors,if installed at the time of the test,shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,If installed at the time of the test,shall be turned off. 6Supply and return registers,if Installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification it: 5010864 Issuing Authority: BPI - Building Performance Institute ;/easide Envelope Leakage Test Report (Blower Door Test) icEs Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2946 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 102 NE 7th Avenue Bldg: 1 Unit: 202 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy ta'lc/(Perfforrmance)or R406-1017(ERI):( x 60 + $r152 = y/ J 4( Method for falculatingbuildingvolumr. CFM(50) Building Volume AC/H(50) ® Retrieved from architectural plans I'PASS ❑FAIL O Code software calculated ❑When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated Installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers Including exhaust intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test shall be turned off. 6Supply and return registers,if installed at the time of the test shell be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: a• wiir Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority:BPI - Building Performance Institute Qjc'aside Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2946 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 102 NE 7th Avenue Bldg: 1 Unit: 203 SQ/FT: 709 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescrlptwe,or ER!Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI):I ] Y (O/ x 60 + 6,310 = yr 14 Method faacdlculati buildingvoklmr CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans I/VPASS ElFAIL O code software calculated ❑When ACH(50)is less than 3,Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth In Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other Infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Intedor doors,if installed at the time of the test,shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and seated. 5.Heating and cooling systems,If installed at the time of the test,shall be turned off. 6Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: `—i Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute easide Envelope Leakage Test Report (Blower Door Test) SER , c E S Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2946 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 102 NE 7th Avenue Bldg: 1 Unit: 204 SQ/FT: 709 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. u 7ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI): 7 '/ x 60 + 6,310 .4' Z,5 MethodfotsalcularingbuildingvolumP. CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans 71PASS 7FAIL 0 Code software calculated ❑When ACH(50)is less than 3,Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth In Section 489.105(3Xf),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interlor doors,if Installed at the time of the test,shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,If installed at the time of the test shall be turned off. 6Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance m�ethoddsselected above. Signature of Tester: ✓ Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute a\asideEnvelope Leakage Test Report (Blower Door Test) ICES Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2946 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 102 NE 7th Avenue Bldg: 1 Unit: 205 SQ/FT: 709 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI):1 ] 9 3 2 x 60 + 6,310 = I� /Z Method tQtcalculat ilg hnil ling yob imp. CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans FIPASS ❑FAIL O Code software calculated ❑When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers Including exhaust intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interlor doors,if Installed at the time of the test,shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if Installed at the time of the test,shall be turned off. 6.Supply and return registers,if Installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: \.-Zil Date of Test: 10/12/2020 • Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority:BPI - Building Performance Institute :/easide Envelope Leakage Test Report (Blower Door Test) vicFs Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2946 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Bik: Address: 102 NE 7th Avenue Bldg: 1 Unit: 206 SOFT: 709 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Caic(Performance)or R406.2017(ER!: 3 y I x 60 + 6,310 = 3, 2 Method faccalrndating buildingvolume• CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS FAIL O Code software calculated ['When ACI-I(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted In accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined In section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3X().(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers Including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. S.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,If installed at the time of the test shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: L� = / - : _ Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 IssuingAuthority:BPI - Building Performance Institute SERCES Envelope Leakage Test Report (Blower Door Test) VI Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2946 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 102 NE 7th Avenue Bldg: 1 Unit: 207 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form 12405-2017-Energy Calc(Performance)or R406-2017(ERQ: 519 7 x 60 + 8,152 = 3, 4's Method forcalculatingbuilding volume' CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS FAIL O code software calculated ❑When ACH(50)is less than 3, Mechanical Ventilation Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted In accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according tothecompliance method selected above. ��7i/ Signature of Tester: - - Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute :.easide Envelope Leakage Test Report (Blower Door Test) SERVICES Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2946 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 102 NE 7th Avenue Bldg: 1 Unit: 208 SO/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form 12405-2017-Energy Calc(Performance)or R406-2017(ERO: ,S''Z 8 x 60 + 8,152 = ,3, g e Method faisalrulating.buildinvvolume• CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS FAIL O Code software calculated C When ACH(50)is less than 3, Mechanical Ventilation ' ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined in Settlon 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond Intended Infiltration control measures. 3.Interior doors,If installed at the time of the test,shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shallbe turned off. 6.Supply and return registers,If installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: '7l/�. � c. Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute :/-aside Envelope Leakage Test Report (Blower Door Test) SEG`: ic ES Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2946 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 102 NE 7th Avenue Bldg: 1 Unit: 209 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R40S-2017-Energy Calc(Performance)or 8406-20l7(ERI): 5:4. x 60 + 8,152 = c/, /Z— Method for calculatlnehliildinpvolumr• CFM(50) Building Volume ACH(50) Retrieved from architectural plans [PASS ❑FAIL O Code software calculated when ACH(50)is less than 3, Mechanical Ventilation Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined In section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in section 489.105(3)(f),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterlor windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the Intended weatherstripping or other infiltration control measures. 2.Dampers Including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. S.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute aaside Envelope Leakage Test Report (Blower Door Test) SRVICE a Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit #: 19-2946 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 102 NE 7th Avenue Bldg: 1 Unit: 210 SO/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. � j /ACH(50)specified on Form 12405-2017-Energy Caicc(Performance)or R406-2017(ERI):I 1 J / (O x 60 + 8,152 = 3 , 7 / MerhndfQLcalf'dating building volume. CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans INPASS F1FAIL O Code software calculated When ACH(50)is less than 3,Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted In accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond Intended infiltration control measures. 3.Interior doors,if installed at the time of the test shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. S.Heating and cooling systems,If Installed at the time of the test shall be turned off. 6.Supply and return registers,if Installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: I/ . =s Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute Qaside Envelope Leakage Test Report (Blower Door Test) RVICES Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2946 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 102 NE 7th Avenue Bldg: 1 Unit: 211 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. �7 ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI): Sr/ 8 x 60 + 8,152 = e 75— Method for calcnlatinghuildingvnhimP• CFM(50) Building Volume A H(50) ® Retrieved from architectural plans PASS ❑FAIL O Code software calculated D When ACH(50)is less than 3,Mechanical Ventilation Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)((),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterlor windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other Infiltration control measures. 2.Dampers including exhaust intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interlor doors,if Installed at the time of the test shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems.If installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto • License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute ;/easide Envelope Leakage Test Report (Blower Door Test) SERv .CES Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2946 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 102 NE 7th Avenue Bldg: 1 Unit: 212 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI): 9_133 x 60 + 8,152 = 3 , 61- Method for Ealndaringbuilding,volumr• CFM(50) Building Volume ACH(50) la Retrieved from architectural plans IIPASS I (FAIL O Code software calculated ['When ACFI(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted In accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the Intended weatherstripping or other Infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond Intended infiltration control measures. 3.Intenor doors,if installed at the time of the test,shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if Installed at the time of the test,shall be turned off. 6.Supply and return registers,if Installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. • Signature of Tester: Date of Test: 10/12/2020 lor Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute �/easidVIC e Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2946 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 102 NE 7th Avenue Bldg: 1 Unit: 301 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calc(Performance)maor 8406.2017(ERI):I 1 S6 3 x 60 + 8,518 = 3 , 9(O Methn tfa[caklUating building volumr CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans [SPASS ❑FAIL O Code software calculated C When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth In Section 489.105(3)(f),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the Intended weatherstripping or other Infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond Intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. S.Heating and cooling systems,if installed at the time of the test shall be turned off. 6Supply and return registers,If Installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements accordingd/tttothe �compliance method// selected above. Signature of Tester: / otl/✓ Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute :/easide Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition • Jurisdiction: Boynton Beach Permit#: 19-2946 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 102 NE 7th Avenue Bldg: 1 Unit: 302 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 Inch w.g.(50 pascals)In Climate Zones 1 and 2. • OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form 8405-2017-Energy Calc(Performance)or R406-2017(ERI): Sid x 60 + 8,518 =_11.0 Methodfpccalrulatiag.building.volumP• CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans IIPASS FAIL O Code software calculated ❑When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted In accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the Intended weatherstripping or other Infiltration control measures. i 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. - 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if Installed at the time of the test,shall be turned off. 65upply and retum registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: ----0/ ..34. .-4� Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute :/;aside Envelope Leakage Test Report (Blower Door Test) S E R V I C E S Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2946 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 102 NE 7th Avenue Bldg: 1 Unit: 303 SQ/FT: 709 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specked on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI):( I T7 3 x 60 + 6,594 = , 30 Mrthodfaica(rularinghuildingvnhtmP. CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans (PASS riFAIL O code software calculated ❑When ACH(50)is less than 3,Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth In Section 489.105(3)(f),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers Including exhaust,Intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond Intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,If Installed at the time of the test,shall be turned off. 6.Supply and return registers,If Installed at the time of the test shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: `— tit Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute ;/easide Envelope Leakage Test Report (Blower Door Test) SERVICES Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach I Permit#: 19-2946 Job Information Builder: RS Construction Community: Ocean,Breeze East Apartments Lot: Blk: Address: 102 NE 7th Avenue Bldg: 1 Unit: 304 SQ/FT: 709 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(SO)specified on Form R405-2017-Energy Calc or(Performance)or R406-2017(ER!: 1 5-3 a y, O x 60 + 6,594 = y Mcthnd for calfulatingbuildingvolumr• CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans 1 IPASS ❑FAIL O Code software calculated ❑When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either indMduals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other Infiltration control measures. 2.Dampers including exhaust,Intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,If Installed at the time of the test,shall be turned off. 6.Supply and return registers,if Installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: 77/i Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute :/Coside Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit #: 19-2946 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 102 NE 7th Avenue Bldg: 1 Unit: 305 SQ/FT: 709 City: Boynton Beach ' ' State: FL Zip: 33435 • Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ER!Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 02 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)speed on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI): SZ 3 x 60 + 6,594 = 76e- Method fgLcalculatinPbuildingvolllmP• CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS ❑FAIL O Code software calculated ❑When ACH(50)is less than 3,Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the Intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond Intended infiltration control measures. 3.Interior doors,if installed at the time of the test shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and retum registers,if installed at the time of the test shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: r71 Date of Test: 10/12/2020 -- Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute :/easide Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance • 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2946 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 102 NE 7th Avenue Bldg: 1 Unit: 306 SQ/FT: 709 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form 8405-2017-Energy Calc(Performance)or 8406-2017(ERI): x 60 + 6,594 = V, 2 Z Method for Selculatingbuildinvvolume. CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS FAIL O Code software calculated ❑When ACI-f(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted In accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined In Seaton 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance� method selected above. Signature of Tester: ------ .71' /J. Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute • :seaside Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2946 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 102 NE 7th Avenue Bldg: 1 Unit: 307 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. L/ ACH(50)specified on Form 8405-2017-EnergyCalc(Performance)� or 8406-2017(ERQ: ( -CZ x 60 + 8,518 = .�i /I Method for calculating buildingvobtmr CFM(50) Building Volume ACH(50) Retrieved from architectural plans n PASS i (FAIL O Code software calculated ❑When ACH(50)is less than 3,Mechanical Ventilation Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other Infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if Installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: I/. / - Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute aSaside Envelope Leakage Test Report (Blower Door Test) RViCE.S Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach I Permit#: 19-2946 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 102 NE 7th Avenue Bldg: 1 Unit: 308 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing resuhs must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. '// ACH(50)specified on Form R405-2077-Energy Calc(Performance)or R406-2017(ERI): 7 b 7 x 60 + 8,518 = 3, 26' Method for calculating hyildipglnblmr CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS [1FAIL O Code software calculated ❑When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted In accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined In Section 553.993(5)or(7),Florida Statues,or Individuals licensed as set forth In Section 489.105(3Hf),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers Including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond Intended infiltration control measures. 3.Interior doors,if installed at the time of the test.shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,If installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: 5 Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute :✓easide Envelope Leakage Test Report (Blower Door Test) ER VICES Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2946 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 102 NE 7th Avenue Bldg: 1 Unit: 309 SO/FT: 916 City: Boynton Beach State: FL Zip: 33435 Mr Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. Q ACH(50)specified on Form R405-2017-EnergyCalkc/(Perrfoormance)or R406-2017(ERI): l�J J 7 x 60 + 8,518 = 7, 7e' Method for calculating building volume. CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans 1>IPASs FIFAIL O Code software calculated ❑When ACH(50)is less than 3,Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Sect:on 489.105(3)(f),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended Infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if Installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy , Conservation requirements according to the compliance method selected above. Signature of Tester: ti Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute :j aside Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2946 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 102 NE 7th Avenue Bldg: 1 Unit: 310 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI):1-1 6 8 I x 60 + 8,518 = '{, '2 7 Method for calculatingbuildingyoliimP CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans [ICPASS ❑FAIL O Code software calculated ❑When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted In accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth In Section 489.105(3Rf),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers Including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,If installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: 2/ • as Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lo_to License/Certification #: 5010864 Issuing Authority:BPI - Building Performance Institute aEnide Envelope Leakage Test Report (Blower Door Test) V I C E 9 Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach I Permit #: 19-2946 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 102 NE 7th Avenue Bldg: 1 Unit: 311 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 • Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ER!Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form 8405.2017-Energy Calc(Performance)or 8406-2017(ERI):I 1 S6-4- x 60 + 8,518 = 3 , °3p' Method for calrulatingbuildinavolume CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans ®PASS ❑FAIL O Code software calculated C When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth In Section 489.105(3)(f),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the Intended weatherstripping or other infiltration control measures. 2.Dampers Including exhaust,Intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond Intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. _ 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,If installed at the time of the test,shall be fully open. Testing Company • Company Name: Seaside Services Org., LLC Phone: 954-778-7358 . I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: r4f Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: _ 5010864 Issuing Authority:BPI - Building Performance Institute ;seaside Envelope Leakage Test Report (Blower Door Test) SERV:C ES Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2946 Job Information • Builder: RS Construction • Community: Ocean Breeze East Apartments Lot: Blk: Address: 102 NE 7th Avenue Bldg: 1 Unit: 312 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy[Lala(Performance)or R406-2017(ERI):1-I 8-9 7 x 60 + 8,518 = /. 20 Method isalculatingbuildincvobimP• CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans NPASS ❑FAIL 0 Code software calculated ❑When ACH(50)is less than 3,Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted In accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended Infiltration control measures. 3.Interlor doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if Installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: �I at-4 Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: _5010864 _ Issuing Authority: BPI - Building Performance Institute