Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
CER OF OCCU
CO CHECKLIST Permit: 2019-2949 Address: 108 NE 7TH Ave Date: 10/21/2020 PCN:08434521100010010 Build Elect Plumbing Mechanical Site Lighting Irrigation 10/20/2020 10/09/2020 09/30/2020 10/09/2020 Fire Low Voltage Gas Hood Paving Landscaping 10/19/2020 10/08/2020 Roof Fire Alarm Fire Sprinkler Fire Supp Drainage ENGN Final 10/16/2020 10/12/2020 10/15/2020 Req Sat NOTES Outstanding X Revisions Outstanding 19-2948,19-2947,19-2946(Remaining Buildings), 19- Permits 2692(Clubhouse) Tie-in /Form Board Survey Final Survey X Soil Treatment Certificate X Soil Density Rep X / Piling Cert Insulation X Certificate ✓ Elevation Certificate X Approved By:.-r" 1o(2z/Z°Zd Threshold / X J Reference Statues 553.791(11) & 533.79(7)(a) Spec Insp Cert Blower Door Test X Required if application date is after 7/1/2017 Interim Fire X \ Rescue Fees ( l Public Art Fee Zoning Final Approved By: CO Approved By of K /v(flj' oto C:\Users\RemyS\Desktop\Intake Helpful Information\CO Checklist(New)\C0 Checklist(NEW).doc(10/05. 1/06,3/06,8/08, 12/08) • 9/18/2020 Ocean Breese Apartments CO Request-Alex Vega Ocean Breese Apartments CO Request Remy, Svon <RemyS@bbfl.us> Thu 8/13/2020 12:05 PM15 I O G Lei To:Alex Vega <avega@centennialmgt.com>; 1 attachment(44 KB) CO Checklist(NEW).doc; Hey Alex, This is what I want to talk to you about... Since you are almost done with the job I know you guys are going to request some Certificate of Occupancy. I am going to send our checklist for a CO. Which is what my Building Official is looking for. Now here where the issue is going to start happening. All the inspections Documents we are going to need them for each building. • Tie-in/form Boarrd/Surveyl� • • Final Survey,—W • Soil Treatment Certificgte — • Soil Density Report — I/ • Insulation Certificate—l4� • Elevation Certificate( Before and After Construction. With picture and in color) — e • Threshold/Special Inspector Certificate — • Blower Door Test Now I know a lot of these documents was on site and CAP may have picked them up. But we do not have anything. Call me if your confused or need some help. Svo4- Application Y o\ Remy `'—� ApplTechnician �/} Development, Development Services I Mailing Address: P.O. Box 310 I Boynton Beach, Florida 33425 0 Physical Address: 100 E. Ocean Ave. I Boynton Beach, Florida 33435 y1 To N rvP ` 561-742-6283 1.7 RemyS@bbf.us I ® boynton-beach.org/ #100YearsintheMaking Follow us on © gri 0 0 Please be advised that Florida has a broad public records law and all correspondence to me via email may be subject to disclosure.Under Florida records law, email addresses are public records.Therefore, your e-mail communication and your e- mail address may be subject to public disclosure. httpsl/mail.cenlennialmgt.com/owa/tFviewmodel=ReadMessagellemBllemID=AAMkADIIYjM3NzJkLWQ1 YmY W DUSYy04NzI0LTQ1 Q WMzNzE1 YjlxYg... 1/2 Professional Insulators of South Florida FTC Insulation Installation Certificate To: Palm Beach County Date: June 29,2020 Re: Building 4 Address: 701 N Seacrest Blvd Project: Ocean Breeze East The undersigned hereby certifies that insulation has been installed in the above described property as follows: 1. Exterior CBS walls have been insulated with: Spray-on Cellulose Thickness in inches: Fiberglass Blankets Manufacturer: Fi-Foil VR Plus Shield Rock Wool Blankets Density: X Aluminum Foil R-Value: R-7 Rigid Board Polystyrene Other 2. Underside of Roof Deck have been insulated with: Spray-on Cellulose Thickness in inches: 13.8 X Fiberglass Blown Manufacturer: Johns Manville Climate Pro Rock Wool Blankets Density: Aluminum Foil R-Value: R-38 Polyurethane Open Cell SPF Applied Directly to Open Cell SPF insulated with: Spray-on Cellulose Thickness in inches: Fiberglass Blankets Manufacturer: Ignition Barrier Density: Fiberglass Blown R-Value: Cellulose Loose Fill Open Cell SPF 3. Perimeter kneewalls have been insulated with: Fiberglass Blankets Thickness in inches: Fiberglass Loose Fill Manufacturer: Rock Wool Density: Fiberglass Blown R-Value: Cellulose Loose Fill Open Cell SPF 4. Garage/House and Garage under living area walls have been insulated with: Fiberglass Blankets been insulated with: Rock Wool Thickness in inches: Polyurethane Manufacturer: Spray-on Cellulose Density: Open Cell SPF R-Value: 5. The following have been insulated: RS CONSTRUCTION OF DADE, INC ae '0 POMAvj O General Contract/Builder :J: epee Eo SEAL iQ • 2005 :�; CGC1527092 A. : Oi Competency# '•,� ' it? 66 •�4 Professional Insulators of South Florida,Inc. %'rMrOIOflt11�vote nnn..s Insulation Contractor By: By: r I INSPECTION LOG ARA Engineering,INC Lic.No 71118 Eduardo Roman Inspector: PE.,SI Building City of Boynton Beach Building Department-3301 Official Quantum Blvd-Boynton Beach,FL,33426 General RS Construction Contractor: Ocean Breeze-100 NE 7th Ave,Boynton Beach, Project Florida Permit# 19-00002949 PCN 08-43-45-21-10-001-0010 Reference: Building 4 Inspection log detail Inspection Date Inspection 0 Type of Inspection Comments PASSED Approving Signature 2/14/2020 1010 Footer 2/14/2020 1020 Foundation , 2/14/2020 1030 SOG steal reinforcement i 2/26/2020 1100 First Floor=Vertical Steel Column Reinforcemnt f Y2/26/2020 1110 First Floor=Rll cell Inspection qtr" 2/28/2020 1030 Second Floor: Slab steal reinforcement y y 3/12/2020 1100 Second Floor=Vertical Steel Column V N Reinforcemnt 3/12/2020 1110 Second Floor=fill cell Inspection Ple" � 3/13/2020 1030 Thrid Floor: Slab steal reinforcement -s;f/ 3/28/2020 1100 Thrid Floor=Vertical Steel Column Reinforcemnt 3/28/2020 1110 Thrld Floor=fill cell Inspection 3/28/2020 Bond Beam 4/12/2020 1400 Roof Truss erection 4/20/2020 1450 Roof Sheathing fir 4/22/2020 1460 Roof Engineering Bracing - 1475 Window Buck and Letter I D/L/GEN I -800-D!L!GENT MyDiligent.com TERMITE SERVICES CALL DILIGENT FOR State License JB228623 Building together, Growing Together CONCRETE WASHOUT! Notice of Preventative Treatment for Termites ..2_735 �(aass requiredeqby Florida Building Code2./2- 2--c; 2326.5 aand�Broward Counttyy Chapter FBC 105.2.2) // �/ SERVICE ORDER NUMBER I U 2 35 SERVICE DATE 2 / U TIME /C .'c/Qarn WEATHER CONDITIONS ` Ieck r DEVELOPMENT NAME(PROJECT) CON CTOR'S NAME CONTACT PERSON 9190111erceueserf- 807#177.-vvVlufC\/5 oull&y-s O5CC ( STRUCTURE ADDRESS(LOT/BLOCK) CITY.STATE,ZIP CODE COUNTY /00 Ne 7"' Ave. , ;t. fl 6cacA ,CCL 15V 5S- CONTACT fCONTACT PHONE NUMBER NOTES )tb' N7 -366 Biel v TREATMENT TYPE/AREA 0 FLOATING yl MONOLITHIC 0 PATIO 0 GARAGE 0 DRIVEWAY 0 STEM WALL 0 ADDITION 0 CUTOUTS 0 FOOTERS 0 FRONT ENTRY 0 EXTERIOR PERIMETER FOR RENEWAL 0 OTHER TREATMENT TYPE • AMP 8 TREAT 0 TREAT ONLY 0 FINAL 0 RETREAT 0 BORA CARE TREATMENT U TERMITE BAR STATION ._ ��`�PRODUCTPP_��_��� OMINION 0 ADONIS 2F 0 PREMISE 0 DEMON TC 0 TERMIDOR 0 BORACARE 0 OTHER —_ ACTIVE INGREDIENTYf14-7:-v -- - - CONCENTRATION .. �RN1ITE SFR 0.05% 0.06% ��t% 0.12% 0.25% BOTHER— GALLONS APPLIED �� •• ` SQUARE FOOTAGE `l I Uq It +C• P P•o R ,••C ,t LINEAR FOOTAGE �•0 s 0 9 ci'? A 1 Et t QUARE FOOTAGE VERIFIED �A ���if , VES 0 NO 0 MEASURED OR VERIFIED PER PLANS ` Q f ,•..o \o ; • .R. • JOB READY CONDITIONS MET * ' • yry YES 0 NO DETAILS // I �--� SAFETY CONDITIONS C-.{cod. As per 2326.5 FBC-If soil chemical barrier method for termite prevention is used.Final exterior treatment shall be completed prior to final building approval. Certificate of Compliance:The building has received a complete treatment for the prevention of subterranean termites.Treatment is in accordance with rules and laws established by the Florida Department of Agriculture and Consumer Services.(Per the Florida Building Code.) If this notice is for the final exterior treatment.initial and date this line (TERMITE MONITOR INSTALLED 0 YES 0 NO) FINAL STICKER 0 ELECTRICAL PANEL 0 WATER HEATER OTHER Payment Terms: Customer's payment in full is due at time of initial service.Customer agrees that a finance charge in the amount of 18%per annum will be assessed on all unpaid balances that are not satisfied by the due date. In the event a collection process becomes necessary to recover an unpaid balance the following fees will be assessed including but not limited to: collection service fee,attorney's fee,finance charges and non-sufficient funds paymontfee. Customer will be responsible for paying all sts asso ' ad with any collection process. � �. � 2 o Date Applicator(Diligent Services '--- ,2---/2-2_0 -,2--/2.2CJ S Date Customer(Property Owner or Agent) Corporate 3500 NW Boca Raton Blvd. I Suite 714 I Boca Raton, Florida 33431 I 1-800-DILIGENT I mydiligent.com • rill out: 1, cCITY OF BOYNTON BEACH 0 '\ v DEVELOPMENT DEPARTMENT I BUILDING DIVISION *r+.• �� 100 East Boynton Beach Boulevard•Boynton Beach,FL 33425•(561)742-6350•Fax 742-6357 Special Inspector Application In accordance with Section 110 of the City of the Boynton Beach Amendments to the Florida Building Code the request for a Special Structural Inspector,a Florida Registered Architect or Licensed Engineer,to perform the following mandatory or discretionary inspections, as outlined In Section 110 of the Florida Building Code. The Special/Threshold Inspector shall maintain progress Inspection reports onsite during construction, submit to the Jurisdiction on a weekly basis inspections reports, and provide a Certificate of Compliance after al I work i s complete to the Building Official before the final inspection as per Section 110 of the Florida Building Code. Note: The Building Official shall determine which discretionary Inspectionsare to be delegated. Name of Project:_Ocean Breeze Permit#19-2649,19-2648,19.2647,19-2646,19-2692 Date:6/8/2020 Project Address: 700 N.Seacrest Blvd Zip Code:33435 Legal Description: PCN:08-43-45-21-00-000-0021 A. Mandatory Inspections Type: 1) Stern wall,monolithic slab on grade,footings/grade beams,pilings and pile caps. EYES ONO 2) Lintel,tie beams,columns,masonry units,reinforcing steel and shoring. RYES ONO 3) Structural Steel;connections,welding,bolts and anchor rods. OYES ENO 4) Smoke Control Systems. OYES IDNO 5) Threshold Building(fs section 553.79(5)) OYES ENO B.Discretionary Inspection Type:Per Building Offidal 1) Buildings and structures of unusual design or methods of construction. OYES ENO • Windows and doors OYES ONO • Structural and fire resistance integrity• EYES ONO 2) Buildings of Type I construction. OYES ONO 3) Major structural alterations OYES[ENO 4) Where the concrete design is based on compressive strength in excess of 3,000 pounds per square Inch. OYES 5CINO 5) Buildings with an area greater than 20,000 square feet. OYES®NO 6) For buildings more than 2 stories in height OYES ONO • 7) Pile driving. OYES ONO B) Private Provider. °structural °Electrical OPlumbing °Medtanftal OYES ONO 9) Other. EYES ONO FIRE RATED PENETRATION IN CONCRETE SLAB AND DRYWALL C. Mandatory Documentation; 1) Inspection schedule stating the specific inspection that will be made and at what phase of construction must •- r. ed with this application. 2) Progress report/inspection reports during construction. 3) Certificate of Compliance shall be submitted prior to the scheduling of the fin. ••i din:,,jr :- Owners Printed name: LewisSwezy y: : �/' tt1 ,111111aa, Permit Holders Printed Name: L- Is we gnatur `` - N\ VARDO R Permit Holders license a: CGC-000308 er- �` # L'''''.� Special Building Inspector Printed Name: Eduardo A.Roman Signature: — ;• �9 ❑Registered Architect and/or CEJ licensed Engineer _Xi • Wq 2? Special Inspector Signature: .,nn'• S7 Special Inspector Address: 7446 NW 115th Ter,Parkland FL 33076 -``.••- ,o&O 7F OF ;• end` State of Florida Registration it PE 71118 i� RIDA Phone: 5$_4-]jl-SgyFax:___Email:ecluardo@ara-englneering.com �7/ iq ,,•, /11/1111 Itt•' 'Plans for all buildings shall indicate how required structural and fire resistance integrity will be maintained where a penetration of a required fire resistant wall, floor or partition will be made for electrical,gas,mechanical,plumbing and communication conduits, pipes and systems.Such plans shall also indicate in sufficient detail how the fire integrity will be maintained where required fire resistant floors intersect the exterior walls and where joints occur in required fire resistant construction assemblies. S:tDevelopmentIBUILDINGtThreahold_Private Provider 2017 Forms\Special inspector Private Provider Apparallon.docx 1A ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING February 14th, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 N. Project: Ocean Breeze cv 100 NE Th Avenue, Boynton Beach, FL 1n . CO Permit #: 19-00002949 a PCN: 08-43-45-2010-001-0010 m Reference: Building 4 SOG, foundation, and fill cells 0 E Dear Building Official: 0 • This is to certify that this office has observed the above reference reinforcement and it is in lo • accordance to the approved drawings.byARA•Engineering, INC. w No exceptions taken. ■ .- O Best Regards, ■ -- ■ D ■ ```oo( IIIII 1 u- o y \\��1t 11111 \ \••••-,,S)• A ,,, o no `* . N ,. _ 111 w �pQ�'. STATE OF ..' (VU. -":�/• '•G 9 �9�" . •• % ,''%SS/ONAL E-I-NO`• •,i�S/ONAI- `\\. 1j11111110‘` Eduardo Roman PE.,SI. PRESIDENT PE 7111.8 • ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 20, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N co Permit#: 19-00002949 Reference: Building 4 Fill Cells?3rd Floor ° Dear Building Official: 11111111 E This is to certify that this office has observed the above reference reinforcement and it is in g accordance'of4the'approvedidrawings by the City of Boynton'Beach. No excep'tions'taken. a) Best Regards, . :6 Rp0 ''• 'j. v Q \G N2 , 0.�71/1//y/////q�'/�//,//�.�� * N0. E * Luz. [ FiT lII 0J � • -, , STATE OF �\ � ' •'• • / NALt-i S'• (9R.19Gt\‘ // /S70NAt \ 1t1I1111t Eduardo Roman PE., SI. PRESIDENT PE 71118 ns - ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 7, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze N. 100 NE 7th Avenue, Boynton Beach, FL o1 Q N Permit#: 19-00002949 Co Reference: Building 4 Fill Cellsr2nd Floor 4 N Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in o accordancce•of•the•approved+drawings by the City of Boynton•Beach. 0 No excep-tions'taken. a) 111 C CO tu Best Regards, 0 AlL ___ A..R. 0, co lz Cu * C_- , T �� Z- O /(�J� CC �•Q STATE OF ..Qtz, � '111IlIlitt Eduardo Roman PE., SI. PRESIDENT PE 71118 Ift JiI MNIMI , MIME ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING February 26, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze N. CV 100 NE 7'h Avenue, Boynton Beach, FL tipN co Permit #: 19-00002949 If) PCN: 08-43-45-2010-001-0010 m Reference: ding 41st-2nd All Cell o E Dear Building Official: This is to certify that this office has observed the above reference reinforcement and it is in accordance to the approved draw•ings•byARA•Engineering, INC. No exceptions taken. ■� ®o ■ -o Best Regards, `od1 I I I 1111 hhh o 11111111111,, ..1 QO A. R '% ai * ' No. — ` 7111 I14 W • L • ••', O#0,.• F[ORIDF \�` ,;# n'..CLORIDP;••••C S, ',�'SS�ONAL ENG�‘ ."///79/0N—Ai 1� / 11111111\\ !1111111111 Eduardo Roman PE., SI. PRESIDENT PE 71118 • ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 20, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N (N Permit#: 19-00002949 Reference: Building 4 HSS Column 3rd Floor Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in accordance•ofithe'approved'drawings by the City of Boynton each. No excep'tions'taken. 1.11 ■ Best Regards, ■ . ^` ,1111111 ,,, o `t�ttttllllt���, . .. R ` Jp 0........O �P ....... .. O �O'•.,��IO N R,,i1.� i ■ =ca.• LtGENSF * ' NO. � o '. - c:1:0 Alle 1 AIMS c E CLUZ= ce STATE OF c. it: a*.t...‘• G W 'ssl�NAL `•`� ''is/°NAL EN \\‘. Eduardo Roman PE., SI. PRESIDENT PE 71118 . . li ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 7, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze r- 100 NE 7th Avenue, Boynton Beach, FL N Q Permit#: 19-00002949 en N. Reference: Building 4 HSS Column 2nd Floor Ln Dear Building Official: lift E This is to certify that this office has observed the above reference reinforcement and it is in o accordance'of.the'approved.drawings by the City of Boynton each. ,-- No excep"tions•taken. • cn mon■ a) Best Regards, th I m ■ � 111 I'�,, goo " o ‘offitlii,, �PRDO ... R ', 12 �JPRpO A. Rin i, . Ace - p- d 14.9...• O .... N •.;!792ii 4 i�.� r 71 * : _ �--- co • :73 0 STATE OF -((7�: ' • � ...4w,-- cc m ''„4(SS.!c(ORIDP.•�&„` ''•,TONAL ENG.\. W ,''/��ONM: ,\-"\`�� //1/III1111\\\ Eduardo Roman PE., SI. PRESIDENT PE 71118 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING March 24, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 71h Avenue, Boynton Beach, FL N CO (N Permit #: 19-00002949 Co Reference: Building 4 HSS Column 151 Floor ° Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in accordance'of•the'approved'drawings by the City of Boyntondeach. mNo excep"tions•taken. Best Regards, ■ ■� o ```111tIII11i11�� oo\alllddq KciS).0. Ran a �� .• 0C, N IjF'•.Zq- ■ •O. .:,0e,ENSEi•.-.4, ; - k �y �C m Q:. E 77. ..- �o STATE OF : (V�` 7041 V �CO '•is�ONAt- qp• ....... W ��hrI11111111 ''iss/ONAL1�?��\ Eduardo Roman PE., SI. PRESIDENT PE 71118 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 9, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N Permit#: 19-00002949 Reference: Building 4 3'° FloorrSla"b Steel Reinforcement ° Dear Building Official: 111111111111 E This is to certify thahthis office has observed the above reference reinforcement and it is in • accordance'of•the'approved'drawings by the City of BoyntonoBeach. co No excep'tions•taken. a) a) • Best Regards, ■ ■_ ' ` Q lC N '•.' � : !`O �- ENS:.. ' a) *: ' _ ■ . . yy : Q • STATE OF <Lj � . .4�_� a �� ONAL �� , / •O • NG ',,,IIIIlI ` i ,,ANALE .: Eduardo Roman PE., SI. PRESIDENT PE 71118 f A ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING March 4, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze a 100 NE 7'h Avenue, Boynton Beach, FL 0 N N- Permit #: 19-00002949 in PCN: 08-43-45-2010-001-0010 m Reference: Building 4- 2nd Floor slab o E Dear Building Official: 0 ch • This is to certify that this office has observed the above reference reinforcement and it is in v accordance to the approved drawings•by•ARA•Engineering, INC. c 0) ;, No exceptions taken. nom ■ ■ ■ _ 11I III11, • Best Regards, ■ OP ,,, OAR '', PFLO•.. �. p1 , E ,\‘‘‘0 •$0° A.Rn"I, III . ft 0.7111 . * =_ 4p .•''0C. N •..' e_ �"--� * :' : �- 0 Elitio[10. 0TA �C/ = '' -0 13 .'• 14; '"SS'ONAL E?\. UJ �Q�•. STATE OF (l/� ' fitisIIIII"\ .1 �,5/ ,ONAL 0400` ''lrliall ' Eduardo Roman PE., SI. PRESIDENT PE 71118 • ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 22, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N CD Permit#: 19-00002949 co Reference: Building 4 Bond Beam N cn Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in • accordance•of•the'approved'drawings by the City of BoyntomBeach. • No excep"tions'taken. - N ■ m ■• Best Regard ��```nOIA't 1111/,' 11119'II'P!i/ v �QJ��1C Nil R•O-y i� 1 9y 4.. J rENSe .!. . • * tN0. iLimit• ••▪ • STATE OF [Vo` rP' :• �\ ac` S, 1 ., S1O11N11AI.11E`?\`W 1j1111111 ` \ Eduardo Roman PE., SI. PRESIDENT PE 71118 i = ----] ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING February 141h, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze Q 100 NE Th Avenue, Boynton Beach;FL 0 Permit #: 19-00002949. ,- - - ' c`_-,. _- N PCNcr) : 08-43-45-21=10-001=0010 I Reference :Building 4 SOC, foundation, and fill cells , i;1410 ow i r I - 4)030 --I 1 E Dear Building Official ' 1 •• I I_ This is to certify that this Office has observed the above_reference reinforcement and it is in cuac accordance to the approveddrawingsby g' g l 1 ARA En Ineenn ,'INC. I - .i I rn i - - - . -- -e - - - I No exceptions taken. i 1 • f , ,,, SII , °o Best Regards, _--_ _ ! \\ ,. I O A i, .• / • - �0. �kC N -.y2 _ _ o ¢ - -;13S TF_OF (C IL 1 1 w ��p '� STATE OF •'-��; ''�,�OVAL E\�\,. N ., ZONAL EN.`. Eduardo Roman PE., SI. PRESIDENT PE 71118 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING March 4, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze a 100 NE 7m Avenue, Boynton Beach, FL Permit #: 19-00002949 PCN: 08-43-45-21-10-001-0010 Reference: Building 4— 2'd Floor slab j 0317 E Dear Building Official: This is to certify that this office has observed the above reference reinforcement and it is in C accordance to the approved drawings by ARA Engineering, INC. No exceptions taken. 0 Best Regards, F%DO A. 6, 0\01iiii0,11 ,. '' �1GENSF OJ ' L�G N •.!l19 _ JJ 7111_ co o 1 r! • a _ * _ C? •. STATE OF -moo \ i, l� W O • STATE OF ' S NAL e' "/S ' �ONAL Efo\`N Eduardo Roman PE.,SI. PRESIDENT PE 71118 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 9, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL Permit #: 19-00002949 CO Reference: Building 4 3rd Floor Slab Steel Reinforcement 4 I D3 U) ° Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in accordance of the approved drawings by the City of Boynton Beach. No exceptions taken. Best Regards, 10/1 i,R00 A.9D0 A. R q 3 A 1C N 9 �.•.• �IGENgF ���-. Q) O. • e r. i� -(VC\ 5/172 J172C.2 0 Q • STATE OF "C‘ ` •• '�. % S�•. O ? .• . QROr.• G �SS, // �; C,' .' �NAL \\w ' ; �NA �� Eduardo Roman PE., SI. PRESIDENT PE 71118 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING March 24, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL V N Permit#: 19-00002949 Reference: Building 4 HSS Column 1st Floor 41(00 N Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in accordance of the approved drawings by the City of Boynton Beach. cn No exceptions taken. a) m 0 Best Regards, No 000 A P ......:.. Lj a) y2 �p0 A. RO '" No. 1 SN86- ./J � 111 • STATE OF CLei 7=. / S •.at ORM?.•' G\?: - /` � � ['� ` i //iS'ONAL Et� STATE OF :• �U W ///17111111t�` �i ccn. F<OR10 P'• G.���- Of ES Eduardo Roman PE., SI. IONAL I \\` PRESIDENT PE 71118 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 7, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL Permit #: 19-00002949 Reference: Building 4 HSS C mn 2nd Floor 11 00 Ln Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in accordance of the approved drawings by the City of Boynton Beach. No exceptions taken. 0, d Best Regards, m ' ,, „ulnira.0° A. Ro ' . ! ......... 9,00 A. RQ �i Q .•' ocENgF jg : 4,, �,C N * • .2 tri • _ 0 El1I/ 1� tIJ(d1L^ ,- r .7111 .7047 cr .1 i •/ ATE OF r <(/ 0 `‘.‘C-C' �STATE OF CS\ .•-.P<ORION ••- es,. •..tOR,o?.•' ��, '!,`C•ONAL E .. w //7' ONAL E-\ " .111111100° �irtl IIl�` Eduardo Roman PE., SI. PRESIDENT PE 71118 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 20, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N CO Permit#: 19-00002949 Reference: Building 4 HSS Column 3rd Floor 3 II e D U Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in g accordance of the approved drawings by the City of Boynton Beach. No exceptions taken. d a Best Regards, 03 00011111lrrlii� ullllrr `Jp9,p..ARpq' OcyD � O . q a �`<O ,. tG N 79 � . Q �i m * NCEN No. y1 /y I�1!r,�'Ijf' . 71118 •• - Q •• STATE OF •' CV� -y /G�/// USG VAN, EG\� /(C`SS', <ORIDP.•N• i : w '��Irrinlltt � /i,1 ALE \\` Eduardo Roman PE., SI. PRESIDENT PE 71118 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 22, 2020 Building Official City of Boynton Beach Building Department • 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7"' Avenue, Boynton Beach, FL N N Permit#: 19-00002949 Reference: Building 4isklifijaggial 4 Iioo U, N Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in accordance of the approved drawings by the City of Boynton Beach. m No exceptions taken. -64 Best Regards, 1/ 1 _ &lel? . 711 8 E CC /7/02 � �04.... STATE OF ((/�\ :2-1) / / «`"'..."`LLL' a F(ORID>..' \�� O •• STATE OF • k1�� a ''lSS�Q .FLORID?. � -0 ., NAI \ Lyn NAL 10111111io ' Eduardo Roman PE., SI. PRESIDENT PE 71118 Imo: T • C: ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING February 26, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE Ph Avenue, Boynton Beach, FL Permit #: 19-00002949 PCN: 08-43-45-21-10-001-0010 Reference: Building 41st-2nd Fill Cell # f110 1 Dear Building Official: 0 This is to certify that this office has observed the above reference reinforcement and it is in accordance to the approved drawings by ARA Engineering, INC. No exceptions taken. C ti 0 Best Regards, 0 41111111 �` ,, •DO A. R ''�' N coDO A. Roi/ 2 442..• v� " 9 '(�G / (5&• GE:se:2::::„ /�'7 lJvv�".t Er Z • STATE OF W ��012/ STATE OF (, Z •.- \ '•�<ORIOP,.\%\(- •'`• \Z�' Diet,.•• O(OR40.` '• •�4 °NAL �` \ � \\ ., ..EAGN. ,'/i/ 11111I•4 \ Eduardo Roman PE., SI. PRESIDENT PE 71118 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 7, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N V N Permit#: 19-00002949 Reference: Building 4 Fill Cells 2nd Floor ii 1110 N ° Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in accordance of the approved drawings by the City of Boynton Beach. No exceptions taken. d a, Best Regards, a „ illi ,,, E `` 0 q ''% JpFL���A.PCS QRO....•• Rat N OJ a) N .'hy2 oc,, sF .. 9y �.: * = */ N�. 1118 �1 , I No. 1 • — co - O STATE OF �� /� � z -o i � • jO(ORIO a.•'' \ ; ,,� FtORIOP'.• C;• LAI i,,/ONAL \” '' ,,, NA \' Eduardo Roman PE., SI. PRESIDENT PE 71118 f A ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 20, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N V o Permit#: 19-00002949 Reference: Building 4 Fill Cells 3rd Floor '# 1110 - - -- N Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in • accordance of the approved drawings by the City of Boynton Beach. chc • No exceptions taken. CD a) c a) • Best Regards, o Lai \itttlllll�� \1,�1IlI I ?',i p,RD0.A. i9 '1012 PpDO A. Rp i�i�i-_� a �O•. 41G N �>y2 Nse/fC m avikNo. * 7 _ / �. 1118 e ---13,..:co E 0 //? Zg ; 0 cc - O STATE OF Qi...... ST TE OF co ��11 IONAL r—: o' S`VON AL 0-\\ LL, imi lint{\`` / ,I IIIII : 11\1\, Eduardo Roman PE., SI. PRESIDENT PE 71118 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING May 2, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N CO Permit#: 19-00002949 • Reference: Building 4 Roof Truss Erection #- 14 Q 0 U, ° Dear Building Official: This is to certify that this office has observed the truss erection and it is in accordance of the approved drawings by the City of Boynton Beach. cn No exceptions taken. Best Regards, is oNolulu U ,4. ` �,S1C N L Q •' a) sitivyVo. 7111' • co cc , Q • (7 STATE OF (ZU\ , . STATE OF CU\ a iS'•.jP(ORM 'G\�` i C'•.F(ONION.p'i nW1ONALtE ` �\ '/ J10NAL Eduardo Roman PE., SI. PRESIDENT PE 71118 -± 7:1 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING May 14, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N C co Permit#: 19-00002949 NI N. Reference: Building 4 Roof Sheathing 4 biro 4 Dear Building Official: E This is to certify that this office has observed the roof sheathing and it is in accordance of the • approved drawings by the City of Boynton Beach. C No exceptions taken. Iu C C p Best Regards, 6- ::::: ___ O ``` 0 11111100/ \\``II111111ii JP:ypO.... RQ�., �FRpO A. Rp �Q .•' 41C N Tit, e<>/.••• �10EN:::: a) * . &vie. No. , 71118 Cu — ' i o • cOma'. STATE OF • (V. -: -. STA OF G/� co SSO E f /S� , \ w i,i/ NAL1` ` OVAL E�\ ,. 10 1111111 t` Eduardo Roman PE., SI. PRESIDENT PE 71118 is -U C: - • ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS.FORENSIC ENGINEERING May 4, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze N. 100 NE 7th Avenue, Boynton Beach, FL N Q N Permit#: 19-00002949 en N. Reference: Building 4 Roof Engineering 41950 4 Ln Dear Building Official: E This is to certify that this office has observed the roof engineering and it is in accordance of the o approved drawings by the City of Boynton Beach. cil . C No exceptions taken. cud c .0) a' Best Regards, o \`\`11111111!!!!!' / 2JRpO A. R � *0p0 A. Rp� 13 f � ✓ IU . �\ NSF '• * :' _ '' 0. 7111 C Eitytedin. * _ O // * CC ,�0 STATE OF •' LVA` /9 I D a 4\ . F(ORlO a. .-'. ?` Cry .•-U: a ///SS70NAL E-��`� %..., Lc• •&.,•LORIOP..'4G,-\; w !!I!I1111111'' •'/I`,S/ONAL EN,, Eduardo Roman PE., SI. PRESIDENT PE 71118 fi ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING May 20, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N Permit#: 19-00002949 Reference: Building 4 Window and door bucks if N 7C Dear Building Official: • E This is to certify that this office has observed the installation of the window and door bucks and it is in accordance of the approved drawings by the City of Boynton Beach. No exceptions taken. Best Regards, d co ‘`` p0 A JPR... ...„ pP01 ) QSTATEOF • <V�` o : • . 0 S"ONAL. E�.\`• 'f,f,nll‘‘` Lu Eduardo Roman PE., SI. PRESIDENT PE 71118 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING June 9, 2020 • Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 N Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach;FL co N co Permit #: 19-00002949_--- r _ in Reference: Building-4 Fire Stopping -All Floors m in Dear Building Official: E I o This is to certify that this office has observed the installation fire stopping per the UL th • assemblies listed,in the permit plans approved by the City of Boynton Beach and it is in accordance of said plans. 1 __ -- .. -.- - w No exceptions taken. - - - = - I © Best Regards, o .. a CO Ed" No. 7 _ a : O.'. STATE OF •• (V0: ill ,","1CNAL ENGN of Eduardo Roman PE., SI. PRESIDENT PE 71118 falai ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING June 9, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7"' Avenue, Boynton Beach, FL N Permit #: 19-00002949 Reference: Building 4 Fire Stopping -All Floors Dear Building Official: E This is to certify that this office has observedthe installation fire stopping per the UL assemblies listed in the permit plans approved by the City of poynton Beach and it is in m accordance of said plans. No exceptions taken. ca, Best Regards, O v `,,,;II1111,,,, / *: No. E C'�1K�•/' J/ _ �d^ 7t - 0 '7;73 � ; a STATE OF .a 10 CONAL Eduardo Roman PE.,SI. PRESIDENT PE 71118 AMERICAN TESTING MATERIALS ENGINEERING, LLC Testing Laboratories-Engineering Inspection Services-Chemist-Drilling-Environmental Services 0 1950 West 84th Street Hialeah, Florida 33014-Phone:305-646-1888 Faxronmental 7 Field Density Test of Compacted Soils ASTM D-5195 Client Ocean Breeze,LLC Order It 20-0211 Address: 7735 NW 146th Street,Suite#306,Miami Lakes,FL 33016 Date: 2/112020 . :Project Ocean Breeze East Apartments -Building 4 Gauge SM: 35637 Address: 703 N Seacrest Blvd., Boynton Beach,FL 33435 Phone No: Mike 954 4710256 Area: ITest Number I Location(s) 1 Footing.South end 2 4 Foundation Pad,South end 3 Footing,Center 4 Foundation Pad,Center I5 Footing,Center-North Desaip0en of Matertat Pale brown sand with some rocks FM I Backfilla I Subgrade I I Base Rock Tested Br IPA Test Number 1 2 3 4 5 Depth(in) 12" 12" 12" 12" 12" Reid Density LBICu Ft(Dry Density) 107.3 108.7 . 106.8 108.7 - 108.0 Moisture Contents 3.1 2.9 3.2 5.6 4.4 Maximum Density In the Field(%) 98.7 100.0 98.3 100.0 99.4 Compaction Requirement by Specs 1%) 95,0 95.0 95.0 95.0 95,0 100%Maximum Density(Lab)-AASN10 T180 108.7 108.7 108.7 108.7 108.7 Optimum Moisture(%) 4.5 4.5 4.5 4.5 4.5 Status PASS PASS PASS PASS PASS Remarks Typed By ak Respectfully submitted e,:k;' F m (iU,;.. '�� a -• oc FA/ . (/'Pik. N /� g �k '414 1 Ids. - Quad A 51481 r AMERICAN TES .MA1 a`~ ENGINEERING ?.-. e< �% e •. °RID , i rIb ay WWI oaMltlans is me eras (afm7letsQ ung catcall See Rtact those escaue00 Sort loos to tasted nons maca1Q'onmat OW&l4ett!"" .a.a Twee;dials Fa®eme atm CIC Is a3 as Ms bttll mapeoitle. Ata mutual ptohctloa taSlant the puhlltanm Mania an mamas are stanit6gr as the mntd,rad ammeatia orafoots.sad entn alnalort RR puhllcetiam at tarn archaism a!@acts tam MN regard is rasa* AMERICAN TESTING MATERIALS ENGINEERING, LW. 4111.3\ Testing Laboratories-Engineering Inspection Services-Chemist-Drilling Environmental Services 1950 West 84th Street Hialeah, Florida 33014-Phone:305-848-1888 Fax:305-646-1887 Field Density Test of Compacted Soils ASTIR D-5195 Client Ocean Breeze,LLC Order 0: 20-0211 Address: 7735 NW 146th Street, Suite#306,Miami Lakes,FL 33016 Date: 2/11/2020 Project Ocean Breeze East Apartnents •Building 4 Gauge SIN: 35637 Address: 703 N Seacrest Blvd.,Boynton Beach, FL 33435 Phone No: Mike 954 471 0256 'Area: i• Test Number Location(s) 8 Foundation Pad,Center-North i Description of Material: Pale brown sand with some rocks RLI BadtRD I r Subgrade I Base Rock r Tested By: I Test Number 6 jDeAth(kf) t2" , Reid Density LB/Cu Pt(Dry Density) 107.7 Moisture Contents 5.2 Maximum Density In the Reid(96) 99.1 Compaction Requirement by Specs(x) 95.0 100%Marbeum Density(L.ab)-AASNTO T180 108.7 Optimum Moisture(7i) 4.5 At. 'Status PASS Remarks: Typed By. elf r . .'f'..ii Respectfully sub .. Q t 1t1��o 7 t x r5448�! mem * :�, T AMERICAN P MA 1I• + ENGINEERING ' .. OR .•`tip- r '„'I1,,,,,,inito•,, • Vito mcO cry si I rndeme int»=In(arnt tasted be I Quad dearer*from Nine arcountenet an the tweed iamtlone teethed on on Eternity Tett can 4esbng mama EaOaeeitr' tit la not Mete tide teSpendthe As a=that Randaan to dr.the stale and ounSues ad sedate are albmabed in the aontd ntial:sated*Ot ideate and auUxrdetea Its euhllmharn or SaO It moeMtiOna ara>atn Fran aarrepefte la raterad AMERICAN TESTING MATERIALS ENGINEERING, LLC. wary Testing Laboratories-Engineering Inspection Services-Chemist-Drilling-Environmental Services 4111131 1950 West 84th Street,Hialeah,Florida 33014-Phone:305-646-1888 Fax:305-646-1887 Field Density Test of Compacted Soils ASTM 0-5195 1 Client Ocean Breeze,LLC Order A: 20-0212 •ddresa: 7735 NW 146th Street, Suite ft 306,Miami Lakes,FL 33016 Date: 2/12/2020 • 'Oct Ocean Breeze East Apartments -Building 4 Gauge SIN: 22745 [Address: 703 N Seacrest Blvd., Boynton Beach, FL 33435 )Phone No: Mike 954 4710258 Area: Slab on Grade at Building Test Number Location(s) 7 NE corner of Bldg 8 NW comer of Bldg 9 25 S and 10'W from NE comer of Bldg 10 50'S and 15'E from NW comer of Bldg 11 35 S and 201E from NW comer of Bldg hDescription of Staterial: Pale brown sand with some rocks Fill 1 Backfill 1 x 1 Subgrade I I Base Rock I Tested Br IPA Test Number 7 8 9 10 11 Depth gni 12" 12" 12" 12' 12" Field Density 1e/Cu Ft(Dry Density) 107.2 107.8 107.5 108.3 107.6 Moisture Contents 3.6 6.1 6.1 5.4 6.2 Maximum Density fn the Field 4%) 98.6 99.2 98.9 99.6 99.0 Compaction Requirement by Specs(%) 95.0 95-0 95.0 95.0 95.0 L108100%Maximum Density -AASNTO T180 .7 108.7 108.7 108.7 108.7 aws Optimum Moisture(%) 4.5 4.5 4.5 4.5 4.5 PASS PASS PASS PASS PASS Remarks Typed By: ak Respectfully submi d.; .S-l.:E�M( rf, . % K / lam.''. nVO)&/t Western Cluad�ili,' tE-d 481 AMERICAN Tari M�IAFS EKGtNEERING.:1 ..•:AOR I0 F Shou) a t euCsal®ndtN ane the ProPa (an) tl' tested be round different thosem from enunbrred on the tested locations reported on our 0; Q01 Test Arran=1estna Marais Engineering CLC Is not IP:be held resoaed& _ Asa muluel.protection to diet the publk.and asamue.S elh reports ere submitted nire mnfidentel progeny.of diets and autorizetoe for PublImton of statements comedian mantis from our reports let retuned �w AMERICAN TESTING MATERIALS ENGINEERING, LLC Testing Laboratories-Engineering Inspection Services-Chemist-Drilling-Environmental Services ,,/�,�,rD, 1950 West 84th Street, Hialeah, Florida 33014-Phone:305-646-1888 Faz305 646 1887 Field Density Test of Compacted Soils ASTM D-5195 Client Ocean Breeze,LLC Order it 20-0219 ddress: 7735 NW 146th Street Suite#306, Miami Lakes, FL 33016 Date: 2/19/2020 Project Ocean Breeze East Apartments-Building 4 Gauge SIN: 23082 ! ddress: 703 N Seacrest Blvd.,Boynton Beach, FL 33435 Phone No: Mike 954 4710256 'Area: Test Number Location(s) 12 Final Lift Parking Lot,See Plan Attached location#1 13 Final Lift Parking Lot,See Plan Attached location#2 14 Final Lift,Parking Lot,See Plan Attached location#3 15 Final Lift,Parking Lot,See Plan Attached location#4 16 Final Lift,Parking Lot,See Plan Attached location#5 Description of Materiel: Pale brown sand with some rocks FD I Buda) I I Subgrade I x I Base Rock Tested By: PM (Test Number 12 13 14 15 16 Depth(m) 12" 17 17 17 17 Feld Density LB+Cu R(Dry Density) 107.4 108.8 108.3 109.5 108.4 • Moisture Contents 3.2 ' 5.1 3.2 2.8 4.7 Maximum Density in the Field(%) 98.8 100.1 99.6 100.7 99.7 Compaction Requirement by Specs(%) 95.0 95.0 95.0 95.0 95.0 100%Maximum Density(Lab)-AASNTO T/80 108.7 108.7 108.7 108.7 108.7 Optimum Moisture(%) 4.5 43 4.5 43 43 Sams PASS PASS PASS PASS PASS Remarks Typed By ak UADiiiii • ,,, Respedlully submied fry. 1 ' -.1:%Bascom Quadri,P-E.1151481 _ S��(E - :' L MERICAN TESTING MATERIALSMATERIALS1.•• FLOC.`� ':r4 c•ENGINEER` ING,LLC. . °°�sas�sr onnanosa m t opate O Esta tattwat 61015=1 Ran'test on rh lasted tan=n4<enad on onun ante Test . Tateg oma ereeefeg MC at*mtat bet cesptnatia As a nutail prahe6mOmtl4nn Vie paltaffi csatina alp cepa6 we aibaiCstl ate mad64eWli 10104;:n 4141*ns and atreann rcni Rn patl0adon 01 rats[attSmmtas waft Ras our MUMS O niserterk AMERICAN TESTING MATERIALS ENGINEERING, LLC. Testing Laboratories-Engineering Inspection Services-Chemist-Drilling-Environmental Services 1 1(1 I 0 1%0 West 84th Street,Hialeah, Florida 33014-Phone: 305-646-1888 Fax:305-646-1887 Field Density Test of Compacted Soils ASTM 0-5195 Client Ocean Breeze,US Order#: 20-0219 %Address: 7735 NW 146th Street,Suite#306, Miami Lakes, FL 33016 Date: 2/192020 Project Ocean Brew East Apartments -Building 4 Gauge SIN: 23082 Address: 703 N Seacrest Blvd.,Boynton Beach, FL 33435 Phone No: Mike 954 471 0256 Area: Test Number Location(s) 1 17 Final Lift,Parking Lot,See Plan Attached location#6 18 Final Lift, Parking Lot See Plan Attached location#7 19 Final Lift,Parking Lot,See Plan Attached location#8 20 Final Lift,Parking Lot,See Plan Attached location#9 21 Final Lift,Parking Lot.See Plan Attached location#10 citation of Material: Pale brown sand with some rocks i FED Backfill Sutgrade x Base Rock Tested 8r PM 'Test Number 17 18 19 20 21 Depth(in) 12' 12' 12' 12' 12° Field Density LBCu Ft(Dry Density) 107.5 104.0 106.8 107.3 108.4 Moisture Contents 7.4 3.4 4.1 3.2 4.7 Maximum Density In the Heid(%) 98.9 95.7 98.3 98.7 99.7 Compaction Requitement by Specs(%) 95.0 95.0 95.0 95.0 95.0 100%Maximum Density(Lab)-AASH7O 7180 108.7 108.7 108.7 108.7 108.7 Optimum$Iolsaw(%) 4.5 4.5 4.5 4.5 4.5 ISams PASS PASS PASS PASS PASS Remelts: Tye BY a _ - - - - - .;•tlit;i:17/;/ry Resped(u0y std by, /ettl Ifo. 5'081 481 ` Quadri,PE.ti 5101 k : AMERICAN TESTING MATERIALS _. STATE Of r,;EtdGINEERING,LLC. ?-j'•FL0R10�. `�. illi Wit sttailatt esti rtes Many(math erase t,e toed 6/heti}p it ere tte endle�ams wean= NTtAt. term arm, n�®aaedrhg ac a stmt Oe Cab=meat. •/1,/e/,.,,.,,,,h„>>`- As a ming Wellen b darn to pstit axl Mahn ae mcgra sea tented as tte anrpams cA claret aec ammeetmase lot patiosd szereses Oeettutaaa rou MeteSr cur et ie eeaaraed ca • –1 I. , LSA 1 i m ..__ - j . [l I TI `-' II E3 co IL 1I vIk �� j �I I I I:Iige 4, 1 y yl I , i t.:Wc- ii r" a i.F ;'_ A iti Mi I 1 z ; - _ ri,,, ,,,i, , tik,, ,p„,.. a .. ooirc / F- . 1 w y -4ic`a1 11 ' - 4is - 10 6 (, -v 7tS1 ,1 A el I � t s 777 or /- r�l, � �� --, ycr I moi$= 1il Pt IIII Jji !h - __ b ,I . 1I '1'6:".‘ I:11;1! Zr."1-4T1:4\ilr 7 A-m -11e., !Ft:Fir:: 11 .� F-W[it4iW 2 "'l.. :7. = 1 - a firP : ' -- 0 .-1 E� .. or; - -- - -. I 6e c. �s1 , - fit' ' - - ail I N 1 041 I tO I it r. 0 .74 x�"� t1 -g ..11 I::4 4 for . _Iln J C w``ql�\' , _ dlLL `, 1\V. . , '-Y^ F ', - • fes. I il" 1 Ci le American Testing Materials Engineering, LLC. Tealry hEontorks-Engineering Inspection Services Chemist-Osilling-Environmental Services PROCTOR COMPACTION TEST RESULT • Date 2/10/2020 Order Number 20-0210 ' Client Ocean Breeze,LLC Address _ _ _ 7735 NW 146th Street Suite 0 308.Miami Lakes,FL 33018 --- ---- ------— --- Project _ _ Ocean Breeze East Apartments ._-__ Address . _ 703 N Seaaest Blvd.,Boynton Beach, FL 33435 _____- _____ __ •Sample Location --Job Site ----- ----- -- --- ------------ -- -----—--Soil Description Pale brown sand with some rocks Sampled By PA Reported To I EC LABORATORY TESTING RESULTS (Sample Ninths'. 1 The asap mrprmm MI as m,OnW n®aeo an IN taws/rands tr NmmderSy Barra d mi aria a lot Ftcmw e 1'iw A.MSHm Depurru T-Ins %Moist Dry Den. 1.5 105.7 PROCTOR 3.0 107.2 tag 4.5 108.7 - 5.5 107.5 Optimum Moisture 4.5 108 100%Max Dry Det 1887 98%Dry Density 108.5 - 95%Dry Density 1013 g . Gradation Test/ c, to7 PASSING 31C Sieve 84% r n • ested By EC tab hacked By WO YPwl BY ak . IOs t 7 3 4 5 S Moisture at Respectfully submitted by *i',*i.,`j .F�. 117O y • l� et.a:• OGE-ic ..Oq- aseern Quadri, P.E. 5t481 NG,. ,1 A Special Inspector-Thr4gle Buildings ftitS•C Should any subsoil mrWdiont in the property(arm tasted be found different from those enmsxr6 i. the . repb itt. on our Densly Test AMERICAN TESTING MATERIALS ENGINEERRING,LLC is net to be h ATE r:t: . Asa mutual protection m client the public and ourselves.,as repots are submitted es the=adrift')properNOt - tti ` publication or stdcnenn,oondusions,or entails nam our reports is reset • s c5 -, -.• m Siidl% 71{.. Q.,:jposide Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2949 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 108 NE 7th Avenue Bldg:4 Unit: 101 SQ/FT: 1105 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(S0)speciied on Form R405-2017-Energy Calc(Performance)or R406.2017(FRI):( S34 x 60 + 9,834 zr Method forCdICuIatSg.hllildin&vnlumP• CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans il%PASS ['FAIL O Code software calculated When ACH(50)is less than 3, Mechanical Ventilation Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with AN51/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues,or Individuals licensed as set forth In Section 489.105(3xf),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers Including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond Intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,If installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: a Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute easide Envelope Leakage Test Report (Blower Door Test) E R V I C E S Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2949 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 108 NE 7th Avenue Bldg:4 Unit: 102 SQ/FT 1105 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method • ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406.2017(ERI):1--1 x 60 + 9,834 = 3, 3� Method foLsakiilatinghuildingvolume• CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS ❑FAIL Q Code software calculated D When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted In accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined In Section 553.993(5)or(7),Florida Statues,or Individuals licensed as set forth In Section 489.105(3X0,(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterlor windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the Intended weatherstripping or other Infiltration control measures. 2.Dampers including exhaust,Intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond Intended infiltration control measures. 3.Interior doors,if installed at the time of the test shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,If installed at the time of the test,shall be turned off. 6Supply and return registers,If Installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: SI = Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute aside Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance orfRl Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach I Permit#: 19-2949 Job Information Builder RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 108 NE 7th Avenue Bldg:4 Unit: 103 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. t//� ACH(50)specified on Form R405-2017-Energy Colt(Performance)or 8406-2017(ERO: 7 7Z- x 60 + 8,152 = j, fj . Method for ralculating buildingvnlume• CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS ❑FAIL O Code software calculated When ACH(50)is less than 3,Mechanical Ventilation • © Feld measured and calculated installation must be verified by building department Testing. Testing shall be conducted In accordance with ANSURESNETACC 380 and reported at a pressure or 0.2 inche w.g.(SO Pascals).Testing shall be conducted by either Individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth In Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the Intended weatherstripping or other Infiltration control measures. 2.Dampers including exhaust intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond Intended infiltration control measures. 3.Interlor doors,If Installed at the time of the test shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be tumed off. 6Suppy and return registers,If installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: ..7/7t Date of Test 10/12/2020 Printed Name of Tester. Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute jCaside Envelope Leakage Test Report (Blower Door Test) ERVICES Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2949 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 108 NE 7th Avenue Bldg:4 Unit: 104 SOFT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. (0 PERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form 12405-2017-Energy Calc(Performance)or R406-2017(E121):1-1� �/-V(hh x 60 + 8,152 = ,3. 97 Merhndfoicalndatingbuddingvolume• CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans JPASS ❑FAIL O Code software calculated ❑When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined In Section 553.993(5)or(7),Florida Statues,or Individuals licensed as set forth In Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other Infiltration control measures. 2.Dampers including exhaust,Intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if Installed at the time of the test shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,If installed at the time of the test,shall be turned off. 6Suppy and return registers,If Installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: ,d_f__ il()IDate of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority:BPI - Building Performance Institute easide Envelope Leakage Test Report (Blower Door Test) VICES Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2949 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 108 NE 7th Avenue Bldg:4 Unit: 105 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. '/ ACH(50)specified on Form R405-2017-Energy Calc(Pe�rfformance)or R406-2017(ERI):1-] 7 x 60 + 8,152 = ,3� Lq MethodlncialculatinPbuildingvolume• CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans [PASS F1FAIL 0 Code software calculated ❑When ACH(50)is less than 3,Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined In Section 553.993(5)or(7),Florida Statues,or indMduals licensed as set forth in Section 489.105(3Xf),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,If installed at the time of the test,shall be turned off. 6.Supply and return registers,If Installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: MS • - - Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority:BPI - Building Performance Institute "aside Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2949 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 108 NE 7th Avenue Bldg:4 Unit: 106 SC)/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406-2017(ERP,section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERO: __f x 60 + 8,152 = '?, 20Methodfntcalculatinebuildinvvolumr• C M(50) Building Volume ACH(50) �p'� ® Retrieved from architectural plans I�IPASS FAIL O Code software calculated When ACF1(50)is less than 3, Mechanical Ventilation Field measured and calculated Installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either IndMduals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth In Section 489.105(3Xf),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterlor windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the Intended weatherstripping or other Infiltration control measures. 2.Dampers Including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if Installed at the time of the test,shall be turned off. 6.Supply and return registers,if Installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: G ' a Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute asaside Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2949 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 108 NE 7th Avenue Bldg:4 Unit: 107 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Pe4ormance,Prescriptive,or ER!Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405.2017-Energy Calc(Performance)or R406-2017(ERI):1-I41_1c( _ x 60 + 8,152 = . r 59 Methodfnicatntlatinc huildingvobimir CFM(50) Building Volume ACH(50) (Si Retrieved from architectural plans JKPASS I n(FAIL O Code software calculated C When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted In accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either indNlduals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth In Section 489.105(3Nf),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond Intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 65upply and return registers,if Installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 _ I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: 1771 Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute Vicasi de Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition • Jurisdiction: Boynton Beach Permit#: 19-2949 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 108 NE 7th Avenue Bldg:4 Unit: 108 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. 0 PERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specked on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI):1-, y0p x 60 + 81 152 3_ = t56 Methodtt?tcalculatine buildingvnliimr CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans XPASS ❑FAIL O Code software calculated ❑When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth In Section 489.105(3)0),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond Intended infiltration control measures. 3.Interlor doors,if installed at the time of the test,shall be open. 4.Extedor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. S.Heating and cooling systems,if Installed at the time of the test,shall be turned off. 6.Supply and return registers,if Installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: ----27 Lti Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute V/Paside Envelope Leakage Test Report (Blower Door Test) ER`!IC ES Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2949 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 108 NE 7th Avenue Bldg:4 Unit: 109 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Cal cc(Performance)or R406-2017(ERO: y6 Z x 60 + 8,152 = 3- 19 Method for tabulating building volume. CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS FAIL O Code software calculated When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted In accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined In Section 553.993(5)or(7),Florida Statues,or Individuals licensed as set forth In Section 489.105(3x(),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1,Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers Including exhaust intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interlor doors,if Installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,If Installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: // i .. Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 _ Issuing Authority: BPI - Building Performance Institute a...sj easide Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2949 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 108 NE 7th Avenue Bldg:4 Unit: 110 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. ' ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406.2017(ERO: 7l7�j x 60 + _i 152 = 3, 50 Method foccalculatinghuildingvnlumr• CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS ❑FAIL O Code software calculated ❑When ACH(50)is less than 3,Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined in Section 553.993(5)or(7),Florida Statues,or Individuals licensed as set forth In Section 489.105(3)((),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the Intended weatherstripping or other infiltration control measures. 2.Dampers Including exhaust,Intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interlor doors,if installed at the time of the test,shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,If Installed at the time of the test,shall be turned off. 6.5upply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the complianceconccemethodm�selected above. Signature of Tester: a'( T7G ret Date of Test: _ 10/12/2020 Printed Name of Tester: Michael A. Lotteestto ' License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute ;/eaide Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2949 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 108 NE 7th Avenue Bldg:4 Unit: 111 SOFT: 1105 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Caic(Performance)or R406-2017(ERQ: S9Z X 50 + 9,834 = 3. 6 / Method for calrulatinebuildingvolumP• CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans IIPASs FIFAIL O Code software calculated ❑When ACH(50)is less than 3, Mechanical Ventilation Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either indMduals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3Xf),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond Intended infiltration control measures. 3.Intenor doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: % Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute j "oside Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2949 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 108 NE 7th Avenue Bldg:4 Unit: 112 SQ/FT: 1105 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-EnergyCalc(Performance)or R406-2017(FRO:FC 6Z x 60 + 9,834 = 3, 73 Method foLtakulaling.huldifgvolumP' CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans ®PASS FAIL O Code software calculated El When ACH(50)is less than 3,Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted In accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other Infiltration control measures. 2.Dampers Including exhaust,Intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. St— Signature of Tester: ` Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority:BPI - Building Performance Institute ;/easide Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2949 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 108 NE 7th Avenue Bldg:4 Unit: 201 SQ/FT: 1105 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(SO)specified on Form 8405.2017-Energy Calc(Performance)or R406-2017(ERI):1-1 Sz x 60 + 9,834 = 3', ZO Methodfoccalculatingbuildingvobtme• CFM(50) Building Volume ACH(50) Retrieved from architectural plans ®PASS FAIL O code software calculated E When ACH(50)is less than 3,Mechanical Ventilation ® Field measured and calculated Installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined in Section 553.993(5)or(7),Florida Statues,or indMduals licensed as set forth In Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if Installed at the time of the test,shall be turned off. 6.Supply and return registers,if Installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute :/eaVICESsfde Envelope Leakage Test Report (Blower Door Test) S Ek Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2949 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 108 NE 7th Avenue Bldg:4 Unit: 202 SQ/FT: 1105 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405.2017-Energy Calc(Performance)or R406-2017(ERI):1 --Sre x 60 + 9,834 = 3, 30 Methodforcalcularingbyjklingvolumr• CFM(50) Building Volume ACH(50) Retrieved from architectural plans PASS ❑FAIL O Code software calculated When ACH(50)is less than 3,Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth In Section 489.105(3)(f),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the Intended weatherstripping or other Infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond Intended infiltration control measures. 3.Interior doors,if Installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. S.Heating and cooling systems,if Installed at the time of the test,shall be turned off. 6.Supply and return registers,if Installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance methodetselected above. Signature of Tester: �- a. 4CP- Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute ;%easide Envelope Leakage Test Report (Blower Door Test) SERVICES Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2949 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 108 NE 7th Avenue Bldg:4 Unit: 203 SOFT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing result must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(S0)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI):I—I 5-59 x 60 + _8x152 = / / / Merhodfoccalculating buildingvnluma• CFM(50) Building Volume ACI-1(50) ® Retrieved from architectural plans ®PASS ❑FAIL 0 Code software calculated ❑when ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either indMduals as defined in Section 553.993(5)or(7),Florida Statues,or Individuals licensed as set forth In Section 489.105(3x0,(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. S.Heating and cooling systems,if installed at the time of the test shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., Mt Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according��intotothe compliance� method selected above. Signature of Tester: '"i / v✓ a Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority:BPI - Building Performance Institute Qeffeaside Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2949 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 108 NE 7th Avenue Bldg:4 Unit: 204 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. e� ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406.2017(ERIK�I Sf0 x 60 + 8,1527 = 3, 9 Methodfgc alrulatingbuildingvolumP• CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS ❑FAIL O Code software calculated When ACH(so)is less than 3, Mechanical ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSVRESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3Hf),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interlor doors,if Installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,If installed at the time of the test shall be turned off. 6.Supply and return registers,If Installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method sfffellllected above. Signature of Tester: ✓`_ Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute :J easide Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2949 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 108 NE 7th Avenue Bldg:4 Unit: 205 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406.2017(ERI): , 5-10 x 60 + 8,152 = £ 7S mrthodlocsakuIatingbuildingvolume CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans I /"PASS ElFAIL O Code software calculated ❑When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted In accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues,or ind'Mduals licensed as set forth in Section 489.105(3x0,(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the Intended weatherstripping or other infiltration control measures. 2.Dampers Including exhaust,Intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.1-leating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: . Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 _ Issuing Authority: BPI - Building Performance Institute as ‘oside Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2949 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 108 NE 7th Avenue Bldg:4 Unit: 206 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form 14405-2017-Energy Calc(Performance)or R406-2017(ERI):[-] 596 7 x 60 + 8,152 = 3, 13 FAetbod1otcalrutlatingbuildinvvolume: CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans [XIPASS ElFAIL O Code software calculated ❑When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)0),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,Intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interlor doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6,5upply and return registers,If Installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: t="5/ 7" JaZit Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority:BPI - Building Performance Institute ; S seER asiICESde Envelope Leakage Test Report (Blower Door Test) `.' Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2949 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 108 NE 7th Avenue Bldg:4 Unit: 207 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405.2017-Energy Calc(Performance)or R406-2017(ERI): , 105-7 x 60 + 8,152 = 3.36Method fQLcalculating.buildingvolumP' CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans IXIPASS I 1FAIL O Code software calculated ❑When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted In accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3x1).(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterlor windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers Including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interlor doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if Installed at the time of the test,shall be turned off. 6.Supply and return registers,if Installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selectedelabove. Signature of Tester: .— -fl �ates,Crr Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute Qz easide Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2949 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 108 NE 7th Avenue Bldg:4 Unit: 208 SOFT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescripthre,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI):I 93 x 60 + 8,152 = 3, 62 2 MPthnrtfoLcalrldating buildingvnlumr• C M(50) Building Volume ACH(50) ® Retrieved from architectural plans ,FIC PASS FAIL O Code software calculated D When ACH(50)is less than 3, Mechanical Ventilation Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues,or Individuals licensed as set forth in Section 489.105(3RD,(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,Intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interlor doors,If installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. S.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: I/. %e Date of Test: 10/12/2020 Pr Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute ;/easide Envelope Leakage Test Report (Blower Door Test) VICES Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2949 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: • Address: 108 NE 7th Avenue Bldg:4 Unit: 209 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. q ACH(50)specified on Form 8405-2017-Energy Calc(Performance)or R406-2017(ERI): SO O x 60 + 8,152 ,j - Method fn[calculatingbuildingvolumP. CFM(50) Building Volume ACE-1(50) ® Retrieved from architectural plans PASS FAIL O Code software calculated When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Intedor doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. S.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if Installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC • Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. / Signature of Tester: 10/12/2020 �/ / ,� <<" - Date of Test: Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute ;/ea�iI� E :de Envelope Leakage Test Report (Blower Door Test) stx Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2949 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 108 NE 7th Avenue Bldg:4 Unit: 210 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. �jACH(50)specified on Form R405-2017-Energy Colc(Performance)or R406-2017(ERI): 57 / x 60 + 8,152 = 3, 80 methodfonalri datingbuildingvolumP• CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans JXIPASS I (FAIL O Code software calculated ['When ACH(50)is less than 3,Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either indMduals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth In Section 489.105(3)(f),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterlor windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,Intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interlor doors,if installed at the time of the test shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. S.Heating and cooling systems,If installed at the time of the test,shall be turned off. 6.Supply and return registers,if Installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester:___ ____ _;:sZ/AtitDate of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute aaside Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2949 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 108 NE 7th Avenue Bldg:4 Unit: 211 SO/FT: 1105 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. pACH(50)specified on Form R405.2017-Energy Calc(Performance)or R406-2017(ERI): 1 53 0 x 60 + 9,834 = 3, Z8 Method toL alculatinghuildingvolume• CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS ❑FAIL O code software calculated ❑When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(0,(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,Intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if Installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: .._a51..ter_ Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute Noside Envelope Leakage Test Report (Blower Door Test) SERvIcResidential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2949 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 108 NE 7th Avenue Bldg:4 Unit: 212 SQ/FT: 1105 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ©PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specied on Form P405-2017-Energy Calc(Performance)or R406.2017(ERO: —I /91 X 60 + 9,834 = 3, 0 ( Method fQL.Ldlculatinghuildingvolume. CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS ❑FAIL O Code software calculated ['When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either indNiduals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(/),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust Intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,If Installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: _ 27_ttcre_ Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute �/easide Envelope Leakage Test Report (Blower Door Test) SERVICES Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2949 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 108 NE 7th Avenue BIdg:4 Unit: 301 SQ/FT: 1105 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specgied on Form R405-2017-Energy Caic(Performance)or R406-2017(ER!: 6'&Z x 60 + 10,276 = 3, 51 MefhnrtfOLcaktilatinehuildingvnIume. CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans ®PASS ❑FAIL O Code software calculated ❑When ACH(50)is less than 3,Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined In Section 553.993(5)or(7),Florida Statues,or Individuals licensed as set forth In Section 489.105(3Mf),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the Intended weatherstripping or other infiltration control measures. 2.Dampers Including exhaust,Intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interlor doors,if installed at the time of the test,shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. S.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,If installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: 1/4-CI lr Date of Test: _ 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute Joside eEnvelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2949 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 108 NE 7th Avenue Bldg:4 Unit: 302 SQ/FT: 1105 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or FRI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. 0 PERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM 8405.2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI): _CS/ 7 x 60 + 10,276 = 3, Z' MethnrtfacalculatinebuildinvvolumP' CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans %PASS ❑FAIL O code software calculated C When ACH(50)is less than 3, Mechanical Ventilation Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSVRESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterlor windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Suppy and return registers,If installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: iE Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute Q;,/easide Envelope Leakage Test Report (Blower Door Test) S ER :'i C ES Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2949 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 108 NE 7th Avenue Bldg:4 Unit: 303 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calc(Perrfformance)or R406-2017(ERI):1--1 18 f x 60 + 8,518 = 3, 7 Method foLcal Matin huldllgvolumr CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans ®PASS ❑FAIL 0 code software calculated ❑When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated Installation must be verified by building department. Testing. Testing shall be conducted In accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either IndMduals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the Intended weatherstripping or other Infiltration control measures. 2.Dampers including exhaust,Intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interlor doors,if installed at the time of the test,shall be open. 4.Extenor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. S.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,If installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance� method� selected above. Signature of Tester: N. C/ ) Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute ;/easide Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2949 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 108 NE 7th Avenue Bldg:4 Unit: 304 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form 17405-2017-Energy Calc(Performance)or R406-2017(ERI):F-1 SYz x 60 + Br518 = f, 8 I Method for cakulatngbuildincvolume' CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS ❑FAIL O Code software calculated 0 When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)0,(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test shall be turned off. 6.5upply and return registers,If Installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 __ I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according totothe compliance method selected above. Signature of Tester: —7��� Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute QJ;oside Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2949 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 108 NE 7th Avenue Bldg:4 Unit: 305 SCUFT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ER1 METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form 8405-2017-Energy Calc(Perf foormance)or R406-2017(ERI):1-1 S , x 60 = 8,518 = 3, 0 6p MethodlQLsalrulatingbuildinivalumP. CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans CZPASs FIFAIL 0 Code software calculated D When ACH(50)is less than 3, Mechanical Ventilation 0 Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either indMduals as defined In Section 553.99315)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(1),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterlor windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond Intended infiltration control measures. 3.Interlor doors,If installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,If installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: ��� Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto __ License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute SER CES Envelope Leakage Test Report (Blower Door Test) VI Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2949 Job Information Builder: 115 Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 108 NE 7th Avenue Bldg:4 Unit: 306 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2077-Energy Calc(Performance)or R406-2017(ERI): x 60 + 8,518 = / SC Methodtaafdlsillatinebuildingvnblmr CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans TOPASS El FAIL O code software calculated C When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond Intended infiltration control measures. 3.Interior doors,if Installed at the time of the test shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,If installed at the time of the test shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. • Signature of Tester: // a a Date of Test: 10/12/2020 I Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority:BPI - Building Performance Institute easide Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit #: 19-2949 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 108 NE 7th Avenue Bldg:4 Unit: 307 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ER!: 5 '8 7 x 60 + 8,518 -474 /3 Method for cal �ICLatingbuildingvolumP• CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans JZ]PASS ❑FAIL O Code software calculated C When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues,or Individuals licensed as set forth in Section 489.105(3gf),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers Including exhaust,Intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. / 10/12/2020 Signature of Tester: ii . / . - Date of Test: Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute j 'asicie Envelope leakage Test Report (Blower Door Test) ERVICES Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2949 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 108 NE 7th Avenue Bldg:4 Unit: 308 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ©PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 Inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. (�ACH(50)specified on Form R405-2017-Energy Cale(Performance)or R406-2017(ERI):1-1 6a/ x 60 = 8,518 = 4 r Z g Methodfotcalndatingbuildingvoluma CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans EIPASS ❑FAIL O Code software calculated ❑When ACH(50)is less than 3, Mechanical Ventilation Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted In accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth In Section 489.105(3X♦).(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the parry conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the Intended weatherstripping or other Infiltration control measures. 2.Dampers Including exhaust,Intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: id . Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority:BPI - Building Performance Institute JasideeEnvelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2949 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 108 NE 7th Avenue Bldg:4 Unit: 309 SOFT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. 1�5"ACH(50)specified on Form 12405-2017-Energy Calc(Performance)or R406-2017(ERI): —T � x 60 + 8,518 = 31 / 7 Method lQLcalculatinebuildingvolume. CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS ❑FAIL O Code software calculated D When ACH(50)is less than 3,Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth In Section 439.105(3Hf).(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the Intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,Intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond Intended infiltration control measures. 3.Interior doors,If installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if Installed at the time of the test,shall be fully open. Testing Company Company Name: _Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: --s _2 Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority:BPI - Building Performance Institute :J easide Envelope Leakage Test Report (Blower Door Test) SERVICES Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2949 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 108 NE 7th Avenue Bldg:4 Unit: 310 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACI-I. �f ACH(50)specified on Form R405-2017-Energy CaaIc(Performance)or R406-2017(ERI): 5/ 2 x 60 + 8,518 = 3, 5/ Methnrtf0LCaltulatinabuildinvvoluirt CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans IXJPASS ❑FAIL O Code software calculated ❑When ACH(50)is less than 3, Mechanical Ventilation 0 Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth In Settlon 489.105(3)(0,(g).or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond Intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements accordingdito the compliance method selected above. Signature of Tester: L—771a. Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 _ Issuing Authority: BPI - Building Performance Institute J "aside Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2949 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 108 NE 7th Avenue Bldg:4 Unit: 311 SQ/FT: 1105 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI): 1 Syz x 60 + 10,276 _ = 3, // MethnrtfoLcalculaling.buildingvolume• CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS ❑FAIL O Code software calculated When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 lnche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth In Section 489.105(3Xf),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers Including exhaust Intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interlor doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if Installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements accordingrdito the compliance�mmeeythoodselected above. Signature of Tester: —s - / ' r �{ .�!" �" Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto �✓ License/Certification #: 5010864 _ Issuing Authority:BPI - Building Performance Institute V:/easide Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2949 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 108 NE 7th Avenue Bldg:4 Unit: 312 SQ/FT: 1105 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2077(ER!: 6-68 x 60 + 10,276 = 3, 31 Methodforcaltulatingbuildingvolume CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans rog1PASS ❑FAIL O Code software calculated ❑When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth In Section 489.105(3)If),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the Intended weatherstripping or other Infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond Intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if Installed at the time of the test,shall be turned off. 6.5uppy and return registers,if Installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: //. Sib Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI_- Building Performance Institute