CERT OF OCCU
CO CHECKLIST Permit: 2019-2947 Address: 104 NE 7T14 AVE BLDG 2 Date: 11/3/20 Build Elect Plumbing Mechanical Site Lighting Irrigation 11/02/20 10/26/20 10/01/20 10/20/20 Fire Low Voltage Gas Hood Paving Landscaping 11/03/20 10/21/20 Roof Fire Alarm Fire Sprinkler Fire Supp Drainage ENGN Final 06/10/20 11/02/20 10/27/20 Req Sat NOTES Outstanding X Revisions Outstanding X Permits Tie-in / Form X Board Survey Final Survey X Soil Treatment X Certificate Soil Density Rep X / Piling Cert / _ Insulation X Certificate f Elevation Certificate X Approved By:sas.,_K ttiO41rw Threshold / X Reference Statues 553.791(11) & 533.79(7)(a) Spec Insp Cert Blower Door Test X, Required if application date is after 7/1/2017 Interim Fire X Rescue Fees Public Art Fee Zoning Final Approved By: CO Approved By:e t< 10*201-0 C:\Users\RemyS\Desktop\Intake Helpful Information\CO Checklist(New)\C0 Checklist(NEW).doc(10/05, 1/06,3/06,8/08, 12/08) 9/18/2020 Ocean Breese Apartments CO Request-Alex Vega Ocean Breese Apartments CO Request Remy, Svon <RemyS@bbfl.us> BIDG Thu 8/13/2020 12:05 PM To:Alex Vega <avega@centennialmgt.com>; • 0 1 attachment(44 KB) CO Checklist(NEW).doc; Hey Alex, This is what I want to talk to you about... Since you are almost done with the job I know you guys are going to request some Certificate of Occupancy. I am going to send our checklist for a CO. Which is what my Building Official is looking for. Now here where the issue is going to start happening. All the inspections Documents we are going to need them for each building. • Tie-in/form Board Survey—1I' • Final Survey—O • Soil Treatment Certific4te — • Soil Density Report— • Insulation Certificate— / • Elevation Certificate( Before and After Consttuction. With picture and in color) —D • Threshold/Special Inspector Certificate ea • Blower Door Test-43 Now I know a lot of these documents was on site and CAP may have picked them up. But we do not have anything. Call me if your confused or need some help. G`T Y O Svon Remy Application Technician rDevelopment, Development Services jC_- _ ` = Mailing Address: P.O. Box 310 I Boynton Beach, Florida 33425 Physical Address: 100 E. Ocean Ave. I Boynton Beach, Florida 33435 o ti ro N 6P ` 561-742-6283 p RemyS@bbfl.us I boynton-beach.org/ 11100YearsintheMaking Follow us on © � 0 0 Please be advised that Florida has a broad public records law and all correspondence to me via email may be subject to disclosure.Under Florida records law, email addresses are public records. Therefore,your e-mail communication and your e- mail address may be subject to public disclosure. haps://mail.centennialmgt.com/owa/#viewmodel=ReadMessageltem8ltemID=AAMIcADIlYjM3NzJkLWQ 1 YmYtNDU5Yy04NzIOLTQ1 OWMzNzE1YjIxYg... 1/2 1 -800-DILIGENT D/L/GEN . MyDiligent.com 1ERMITESERVICES CALL DILIGENT FOR State License JB228e23 Building Together, Growing Together CONCRETE WASHOUT! Notice of Preventative Treatment for Termites (as required by Florida Building Code 2326.5 and Broward County Chapter FBC 105.2.2) SERVICE ORDER NUMBER 189306 SERVICE DATE 11/04/2020 TIME 12:(5pm WEATHER CONDmONS Clear DEVELOPMENT NAME(PROJECT) CONTRACTORS NAME CONTACT PERSON OCEAN BREEZE EAST Bldg#2 PHORCYS BUILDERS OSCAR STRUCTURE ADDRESS(LOT/BLOCK) CRY,STATE,ZIP CODE COUNTY 100 NE 7TH AVE BOYNTON BEACH, FL 33435-3807 PALM BEACH CONTACT PHONE NUMBER NOTES 305-549-8834 Final Termite Treatment and Certificate TREATMENT TYPE/AREA O FLOATING O MONOLITHIC O PATIO O GARAGE O DRIVEWAY O STEM WALL O ADDITION O CUTOUTS O FOOTERS O FRONT ENTRY ("EXTERIOR PERIMETER FOR RENEWAL O OTHER IligAlhinalthE O TAMP 8 TREAT O TREAT ONLY ("FINAL 0 RETREAT O BORA CARE TREATMENT O TERMITE BAIT STATION qua DOMINION 0 ADONIS 2F 0 PREMISE 0 DEMON TC 0 TERMIDOR 0 BORACARE 0 OTHER ACTIVE INGREDIENT imidadoprid cONCENTRATIOd 0.05% 0.08% .1% 0.12% 0.25% CI OTHER— GALLONSAPPUED 534 ; • R•• atA1TE$F.. • SQUARE FOOTAGE 10696LISESMEMILISE ; 4o •,oP a R q `-..�CFN•%t ra–e' , i e ;WARE FOOTAGE VERIFIED ei,-.� r r 0 NO 0 MEASURED OR VERIFIED PER PLANS rt ) •t- IES i \ `.. 0R •ss i am READY CONDITIONS MEj * •• YES 0 NO DETAILS SAFETY coNDmoNS good conditions As per 2328.5 FBC-If soil chemical bander method for termite prevention is used.Flnel exterior treatment shall be completed prior to final building approval. Certificate of Cant:dance:The building has received a complete treatment for the prevention of subterranean termites.Treatment is in accordance with rules and laws established by the Florida Department of Agriculture and Consumer Services.(Per the Florida Building Code.) If this notice Is for the final exterior treatment,Initial and date this line 11/04/2020 HC (TERMITE MONITOR INSTALLED 0 YES 0 NO) FINAL STICKER 0 ELECTRICAL PANEL WATER HEATER OTHER Payment Termer Customer's payment In full Is due at time of Initial service.Customer agrees that a finance charge In the amount of 18%pr er um will be assessed on all unpaid balances that are not satisfied by the due date. In the event a collection moans becomes necessary to recover an unpaid balance the following fees will be,...•e ^.'6,Irt.yd not limited to: collection service fee,attorney% financefee, �e charges and nen-sufficient funds payment fee. Customer/will•o,�e poi. .-!.for pa Fall costa associated with any collection process. �' / j-— Date Applicator(Diligent Services) Date Customer(Properly Owner or Agent) 3500 NW Boca Raton Blvd. I Suite 714 I Boca Raton, Florida 33431 I 1-800-DILIGENT I mydiligent.com D/L/�iEN ry 1 -800-DILIGENT MyDiligent.com TERMITESERVICES CALL DILIGENT FOR State License JB228623 Building together, Growing Together 4 CONCRETE WASHOUT! Notice of Preventative Treatment for Termites G{ (as required by Florida Building Code 2326.5 and Broward County Chapter FBC 105.2.2) SERVICE ORDER NUMBER I 'J Q� I SERVICE DATE � /�I 20 TIME 15 5 WEATHER CONDITIONS C I ea{— DEVELOPMENT NAME(PROJECT) CONTRACTOR'S NAME CONTACT PERSON Ocean i)cee eL-A,-* P o c( 5 Qom .\e� c r3 Ck rC. STRUCTURE ADUBESS(LOT/BLOCK) CIN,STATE,ZIP CODE COUNTY L- 7�1 iCO N , Ave . n \cn �cc,c1--1 , F) 53L/35 CONTACT PHONE NUMBER NOTES ! T7�M-75ENT - 3 a5 BIAS 2 0 FLOATING 7-MONOLITHIC 0 PATIO 0 GARAGE 0 DRIVEWAY 0 STEM WALL 0 ADDITION 0 CUTOUTS 0 FOOTERS 0 FRONT ENTRY 0 EXTERIOR PERIMETER FOR RENEWAL 0 OTHER TREATMENT TYPE TAMP&TREAT 0 TREAT ONLY 0 FINAL 0 RETREAT 0 BORA CARE TREATMENT 0 TERMITE BAIT STATION / PRODUCT ( DOMINION 0 ADONIS•� 2F 0 PREMISE •,0 DEMON TC 0 TERMIDOR 0 BORACARE ❑OTHER ACTIVE INGREDIENT 1 evt"'An f I G(1 1':1,4 CONCENTRATION [[ 0.05% 0.06% �p,.1% 0.12% 0.25% O OTHER— GALLONS APPLIED 5 3 5 • .x'o• MITE se.• ,, (0 c �,2�,ee, P O R 1‘•.-(1‘s, SQUARE FOOTAGE IO /Go _I SO LINEAR FOOTAGE i j • 0 -A N `' I. Ad t SQUARE FOOTAGE VERIFIED {7I11 ��,��i ; '•1(y ES 0 NO 0 MEASURED OR VERIFIED PER PLANS 0 • JOB READY CONDITIONS MET ,`‘ • I •e AYES 0 NO DETAILS .. SAFETY CONDITIONS l -1 EXCiA As per 2326.5 FBC-If soil chemical barrier method for termite prevention is used.Final exterior treatment shall be completed prior to final building approval. Certificate of Compliance:The building has received a complete treatment for the prevention of subterranean termites.Treatment is in accordance with rules and laws established by the Florida Department of Agriculture and Consumer Services.(Per the Florida Building Code.) If this notice is for the final exterior treatment,initial and date this line (TERMITE MONITOR INSTALLED 0 YES 0 NO) FINAL STICKER 0 ELECTRICAL PANEL 0 WATER HEATER OTHER Payment Terms: Customer's payment in full Is due at time of initial service.Customer agrees that a finance charge in the amount of 18%per annum will be assessed on all unpaid balances that are not satisfied by the due date. In the event a collection process becomes necessary to recover an unpaid balance the following fees will be assessed including but not limited to: collection service fee,attorney's fee,finance charges and non-sufficient funds paymp/n;fee. ustomer will be reseon for ,. .ng al costs associated with any collection process. I 111 • I Dat Ap•icator�. igent�ervi Vis) .e rte! gr2Di1•Alr ___ Date Gusto ,•rop•rty0 . •r Agep Corporate 3500 N . Boca Raton.Blvd. I Suite 714 I Boca Raton, Florida 33431 I 1-800-DILIGENT I mydiligent.com ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING March 03, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze N- N 100 NE 7th Avenue, Boynton Beach, FL CD N N Permit #: 19-2947 N Reference Building12 Type 2 Fill cells 1s1 to 2nd Dear Buildingefficial: E o This is to certify that this office has observed the above reference reinforcement and it is in accordancence tpproved drawings by ARA Engineering, INC. Zii -o the aw ■No exceptions.taken. • C cu Best Regards, ■ ��,,loo111111,,, _ ■ .::'c\\)FRS-: ..:•Rp. ..„ ..•' OCEN4�c•.72 m -' � `00%11110Ni/i v . JpR•QQ..•:..0.'%, ■ o. & ® :1(<2..•• A1C N 7/', - 'tr '.�*w 7.-- E - 0 0 m p • STATE OF IQ-I" /''�,ONAL E , \`N W '% (� '•.'`.0 ORI9P'.•'...G,\÷;` �1III1 1111\ �� ��'S1.11/1111101- Eduardo CONAL 1EN\‘�� Eduardo Roman PE.,SI. PRESIDENT PE 71118 ARA-.ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING March 24, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N •P ` - Permit#: 19-00002947 Reference: BUILDING 2 Fill Cells 2nd Floor Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in • accordance'ofathe.approvedSdrawings by the City of Boynton'Beach. No excep-tions'taken. c ■ • Best Regards, O ``�itlllllti��� ■ �- 13 N a) iA! *' No. *" AsaAc • - _ 0. 71178 E• ' _ ,* e Oma'. STATE OF :•((�� _ '�-- }:, - p i co Ii/SF • <ORIOP.• ION R 1irinlitt ''SS/ONAL e 1.Eduardo Roman PE., SI. PRESIDENT PE 71118 • ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 6, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N TI tO Permit#: 19-00002947 Reference: BUILDING 2 Fill Cells 3 d Floor co Dear Building Official: Intl E This is to certify that this office has observed the above reference reinforcement and it is in o accordance'of•the'approved'drawings by the City of Boynton'Beach. 1111 dNo exceptions'taken. • Best Regards,Es 0 . ■� cli ■ . Nk,iiiiiiiiiiittf 11 co NJpR........Rp ■ .o` p,ADO 4 v * ' SF.. 219 ...tidi N0. O iI)¢ STATE OF - to` p i4NS'•.F10RIOP.0-‘'.'0..P."..NNN G\ % 1 •. 3TATE0 . �,t: /ate 'iiiillllnt�� Eduardo Roman PE., SI. PRESIDENT PE 71118 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 18, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7t" Avenue, Boynton Beach, FL N Permit#: 19-00002947 co Reference: BUILDING 2 Roof Tirus"rection 4 Ito ° Dear Building Official: E This is to certify that this office has observed the truss erection and it is in accordance of the • approved drawings'by.the'C-ity'of Boynton Beach. S No exceptionsitaken. � ■- d • Best Regards, ■ N ■ ■ Eliftrivo. * Cfei71118 • cc o Q�•. STATE OF Lu 7:=3 /��2 thz' o i v •.;(ORIDP.•• � � 0 • STMfE LU S/11111111101‘IONAL o fts••.FCORIOP.•�C" �/,SIONAL t��. Eduardo Roman PE., SI. PRESIDENT PE 71118 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING May 4, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL (N `° Permit#: 19-00002947 01 Reference: BUILDING 2 Roof Engi eering -41 IM 0 Dear Building Official: it E This is to certify that this office has observed the roof engineering and it is in accordance of the approved drawings.by'the'City'of Boynton Beach. CIC C No exceptions'taken.a) ■- C Best Regards, r ■ .tot moil/ ■ ouritioi JP .. Oi ..... ..v. c.,„ p •.......: Ou 3 �Q .• •41G N .9 •QiLIGEN$Fa..• d * No. _ � 71118 • * 40,J" * I . y,2� 2u � r Q • STATE OF ((7` STATE OF • C(7\ 0 4.%rs •.F<ORIOP'.• G,\ � e' v` •'•..<ORIO?.•'••• w ��1/AN/ONAL €‘40‘` �� SS70NAL ? \\••++++Inlltl� +++llllllll\\\ Eduardo Roman PE., SI. PRESIDENT PE 71118 i -------1 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 27, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 71h Avenue, Boynton Beach, FL N V Permit#: 19-00002947 co N. Reference: BUILDING 2 Roof She" hing ,t 'i,t(0 in cn Dear Building Official: E This is to certify that this office has observed the roof sheathing and it is in accordance of the o approved drawingsby4the'City'of Boynton Beach. m C idii No exceptions taken. ■ c 0) • Best Regards, ■ ■_ a „ web ` lG N •,yam _� •' 19ENSF a) E11 -Y /, *tie41No. 7 _ • _ ( /1118 / ' ,-- � /1118 o pQ STATE OF •• (V : :0 �TAPE a 'i�� •'•.FCORIO?`.•.-.' ÷' �''//r/6:79:.;0". AN ..•.•PCOR\OP:... c.�� ea w „'S;S�ONAL €'0‘\\ , ., i5,`S;ONA1 C `\‘ 1/1111111t )11111111�� Eduardo Roman PE., SI. PRESIDENT PE 71118 in _. ..... _... ...... ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING May 20, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N a N Permit#: 19-00002947 Reference: BUILDING 2 Window and door bucks 1 9 7 Q Dear Building Official: M .. E This is to certify that this office has observed the installation of the window and door bucks and g it is in accordancesof,the'approved drawings by the City of'Bo�omBeach. 0, Pi No exceptions'taken. It 1 Best Regards, 11) ela MN iil �.�` JPON R�� a lit '10 �� . W N E ��Q STATE OF •((�. o '�.,�ONAt ,E o4%.•. w Eduardo Roman PE., SI. PRESIDENT PE 71118 INSPECTION LOG MA Engineering,INC Lic.No 71118 Eduardo Roman Inspector: PE.,SI Building City of Boynton Beach Building Department-3301 Official Quantum Blvd-Boynton Beach,FL,33426 General RS Construction Contractor: Ocean Breeze-100 NE 7th Ave,Boynton Beach, Project Florida Permit fi 19-00002947 PCN 08-43-45-21-10-001-0010 Reference: Building fl 2 Inspection log detail _ Inspection Date Inspection# Type of Inspection Comments PASSED Approving Signature 2/21/2020 1010 Footerf /�� 2/21/2020 1020 Foundation f�V - 2/21/2020 1030 SOG steal reinforcement 3/3/2020 1100 First Floor=Vertical Steel Column Relnforcemnt Filled Cell 3/3/2020 1110 First Floor=fill cell inspection i -1 3/5/2020 1030 Second Floor: Slab steal reinforcement Second Floor=Vertical Steel Column ) 3/20/2020 1100 Relnforcemnt Filled Cell /sss///��' I 3/20/2020 1110 Second Floor=fill cell inspection l/ 3/23/2020 1030 Thud Floor: Slab steal reinforcement Jl 4/6/2020 1100Thdd Floor=Veniwl Steel Column Relnforcemnt Filled Cell �!� 4/6/2020 1110 Thrid Floor=fill cell inspection IF 4/6/2020 Bond Beam I 41� J 4/18/2020 1400 Roof Truss erection (I to 4/27/2020 1450 Roof Sheathing ,9 f 5/4/2020 1460 Roof Engineering Bracing 9 / 49 g:20 "�s.n, 1475 Window Buck and Letter P ti 4 . f A ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING , February 21, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze N. cm 100 NE Th Avenue, Boynton Beach, FL (0 CO N. Permit #: 19-2947 .���� U, Reference: Building-1'2 Type` - 2 SO-G, foundation, and fill cells 4 �D10 m 'l; „ice ZO D Dear Build- ing'Official- thf030 E o This is to certify that this office hasobservedthesabove reference reinforcement and it is in 01 caccordancence tproved drawings by ARA pEngineering, INC. a5 lir° a) No exceptions.taken. c a) C, Best Regards, 0 ■ a 00,1ullrrrr U JP,R Rp ' np,R s.: Rp o ., ry . ® `� �(/:'• 1C N ad teri 641`m * : No. q-�J+.` `-= 711 E � • _ -_.O 7f o - Er _ k _ _ co 13 ���•. STATE OF Cu:. • A• OF �` SI "i/OlIMO'N /1111110'\ Eduardo Roman PE.,SI. PRESIDENT PE 71118 . • f A ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING March 05, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze N Cr 100 NE 7'h Avenue, Boynton Beach, FL CD N N. Permit #: 19-2947 Ti Reference: ing12 -2nd FL slab 0) tar in Dear Bullding'Official: E 0 This is to certify that this office has observed the�abe reference reinforcement and it is in 01accordanceto the drawings by ARA Engineering, INCA m No exceptions.taken. vim_ C C0 I lai Best Regards, `,,i I I I I I/, 0 vy.sackpOaA..Re..'% m S ``O Moo,// \ ..' C\GENS=4, ?p0 A. R lo, ® \*..,.c Oyu ', _`Ir , 1118 � m FAQ t *. STATE OF (f/�� //'/ S O AL �' \v.\ ''/'//�SS�ONAL,E�\`‘\ Eduardo Roman PE.,SI. PRESIDENT • PE 71118 . . f A ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING March 23, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N Q tD Permit #: 19-00002947 N. Reference: BUILDING 2 3rd Floor Slab Steel Reinforcement in co Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in o accordanceiofathe.approvedldrawings by the City of BoyntomBeach. cn No excep'tions'taken. a)Ncn ■ IIIIIIIIIII w Best Regards, . ■� \Wtlllllii ■ �� JP ....... p A 1.., °' a) ` <32 ' S1fC "U^5E`_= \ JQ� \SENSE ' \d" '• t (/.: , — 111 c ta 1. Q '• STATE OF ((7 / !.0 w ��'SS�ONAt tE�G`` �i,q ---- FLOF��P•• \-\ ''CSSIONN�- ‘0\ ,/Illlltttt Eduardo Roman PE., SI. PRESIDENT PE 71118 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING March 3, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N CV Permit#: 19-00002947 I' N. Reference: BUILDING 2 HSS Column 15t Floorin co �F 00 Dear Building Official: IMO This is to certify that this office has observed the above reference reinforcement and it is in E • accordance.of.the•approvededrawings by the City of Boynton•B�each. No excep-tions•taken. . C ■Eh ■� ■ ■ . C ▪ Best Regards, CO .NoOilliiiiif 0 peOVA � o' 9�zR ', III Q ot• N •. 9 . L ea s: SiticittNo. m • . �� *�� . cc ��Q •• STATE OF :.Qt.:, �'�7.)! 1 ZV7 6(V�� �` 7 p .,,i 4%et ....!.<ORT•.•• 0-\, SS �ORID • 4SG?N W �CO 'sS�ONAI E �`�� ��.NAL EN `• t Mil t1\ Eduardo Roman PE., SI. PRESIDENT PE 71118 r -----.-1 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING March 20, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze n 100 NE 7'h Avenue, Boynton Beach, FL N Q co Permit#: 19-00002947 Reference: BUILDING 2 HSS Column 2"d•Floor 4 MOO LI) CD Dear Building Official: , MIN E This is to certify that this office has observed the above reference reinforcement and it is in o accordanccelof.the'approvedodrawings by the City of Boynton each. rth • No excep"tions•taken. c ■■ � d Best Regards, . ■ Ili 111 . .,,,„ ,,,,,,, ■ cit.,coo \\���11 II ,I�/ . m �`�Act.:....0, 0.A. Rp ',i O ��GENse ' .q -0 ; <F. • tC N •. �• AS �. it W 0 7111 ' * ' No. ce � CC Z o �Q •• STATE OF .'••!(/�� '� "citiNORtC:::::effw ��'S;SiONAL e�G�` '''iiL 1 I:ijuI�1\\ Eduardo Roman PE., SI. PRESIDENT PE 71118 fi ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING ' April 6, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze N. 100 NE 7th Avenue, Boynton Beach, FL (N V tO Permit#: 19-00002947 Reference: BUILDING 2 HSS Column 3rd Floor nn Dear Building Official: lift E This is to certify that this office has observed the above reference reinforcement and it is in o accordance'of4he•approvedrdrawings by the City of Boynton'Beach. dNo excep-tions•taken. a) I. �- • Best Regards, 0IIIb Illy/lIII ii, ``„i �liu � �, V (0.. •N..‘Co N '•. ;- Q .' LIC1E`F��7 * ' :No. 71118 : 3 c * iS cc ••• • STATE OF - (Vu` . i7 STA E OF C(/ E i�(O% '•.F(ORID P.•' \+, . •'/.F(ORIDP,. ' �_ V CO ef'///i1°NAl. eNN�� "'c`S�ONAL EAG\ W ''1/1111111111 /'./1111111111\ Eduardo Roman PE., SI. PRESIDENT PE 71118 1 f A ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 6, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze N. 100 NE 7'h Avenue, Boynton Beach, FL N Q N Permit#: 19-00002947 en N. Reference: BUILDING 2 Bond1Beamh _ft itoo inlilt Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in o accordance'of4he'approvedSdrawings by the City of Boynton each. No excep-tions•taken. mco ■ d Best Regards, ■ Co A. \‘`‘_9,00 N ,Ry,9 J• P� cE s?��'/q tu * ' 171118 C _ ' _ L E 0 O: :.Q STATE OF ((7�` '-::33:;577, TCf D� .: -P /co e .••.F<ORM t.••- \_� :O ••. . OR1D?. \\‘‘ l5` ////1/47:9/0r. ` �' SS��NAI �� ,��� SAO ..... w ,,I�NAl1EN�` Eduardo Roman PE., SI. PRESIDENT PE 71118 , • ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING March 03, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 71h Avenue, Boynton Beach, FL N Permit #: 19-2947 cr Reference: Building 2 Type 2 Fill cells 1s' to 2nd di I 1 I an er-- o Dear Bullding'Official: E E This is to certify that this office hs observed the above reference reinforcement and it is in C_ accordance tpproved drawings by ARA Engineering, INC. No exceptions.taken. c uBest Regards, O \\`‘pld,hl Jilgy/// m III11/I/ p0 A. R ' -0 \II 0 A. 1 ' "• o ENse • /moo c�� JpKQ... ..Rp ''%, pJ• • I lc sF ' •9y , El N oJ . No71 C : 40 .' No. , i' ' * .,:= 0 * = 9 D c0 �Q % STATE OF (V: �••••. Fi.OR\OP.•'•G\ w ;As%S/F(ORIo �G;÷� // �e/ONAL ���. \ miiiiii‘o .1 /�/ONAL 11111 Eduardo Roman PE., SI. PRESIDENT PE 71118 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING March 24, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL Permit#: 19-00002947 Reference: BUILDING 2 Fill Cel L°* loor 4 0 ( 0 Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in accordance,ofdhe.approvedildrawings by the City of Boynton•Beach. 111 No exceptions'taken. Best Regards, `1110 1111/� ■_ " (i�. •A:/dp 'i, i, * NO. V1 ■ _ ` �� LICENSE•• / 1�� �yAT.E71O1OF "4/414 � �o �0STATE OF 'i Gm iiWONALt-0\\ cs.'•F<ORIOP .•'.w ; N ONAL Eduardo Roman PE., SI. PRESIDENT PE 71118 . . FA ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 6, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze N. 100 NE 7th Avenue, Boynton Beach, FL N V IN Permit#: 19-00002947 �{ a Reference: BUILDING 2 Fill Cells Floor P 1l10 cn Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in o accordance'of•the.approvedfdrawings by the City of Boynton each. PI d No exceptions^taken. mi O ■ • Best Regards,-13 11111111111 ■ ■ T2 ‘`N11 0 A ��io 1X11Pr1411r, D J•' ' •?fS 't0 (<2.. ocN ' y .2 ' •,* , PR : d p9 /I cENSF 'y r9 _ C 03 E � ..• • �� -� x... 0 O • STATE OF /.0.-:. �J�� ���a� c -o ',SS�ONAL ENO`� ;,�FS,S/F<oRIOP� G��: W ,.'1+IIIIII11` /iii 0NAL 11\1\\\ Eduardo Roman PE., SI. PRESIDENT PE 71118 . i AMERICAN TESTING MATERIALS ENGINEERING, LLC. aidno Testing Laboratories-Engineering Inspection Services-Chemist-Drilling-Environmental Services jor .1(10)1 1950 West 84th Street, Hialeah, Florida 33014-Phone:305-546-1888 Faz305-646-1887 Field Density Test of Compacted Soils ASTIR D5195 Client Ocean Breeze,LLC . Order if: 20-0220 Address: 7735 NW 148th Street,Suite 0 306,Miami Lakes, FL 33016 Date: 220/2020 Project Ocean Breeze East Aparbnents-Building 2 Gauge SIN: 23082 Address: 703 N Seacrest Blvd., Boynton Beach, FL 33435 • Phone No: Mike 954 471 0256 Area: Test Number Location(s) 1 Final Lift,Building Pad(See Plan Attached) 2 Final Lift Building Pad(See Plan Attached) 3 Final Lift,Building Pad(See Plan Attached) 4 Final Lift,Building Pad(See Plan Attached) 5 Final Lift,Building Pad(See Plan Attached) reScription of Material: Brown sand de Fm Backfill : Subgrade Base Rock y Tasted By PM n1 Test Number 1 2 3 4 5 Dela an) 12" 12' 12" 12" 17' Field Density LBCCu Ft(Dry Density) 10.5.4 105.1 104.8 105.9 106.1 pure Contents 4.7 3.8 4.3 4.7 19 Maximum Density 8n the Field(%) 99.3 99.1 98.8 99.8 100.0 Ouagractiorr Requirement by Specs(%) 95.0 95.0 95.0 95.0 95.0 10011 Yarinunm Density(Lab)-AASHID 1180 106.1 106.1 106.1 106.1 106.1 Optimum Moisture(%) 11.2 11.2 11.2 11.2 11.2 Stall PASS PASS PASS PASS PASS Rene:Its Typed Ety. al( e, Aq ,O., Respectfully submitted by. v .••• STATE iv F aseem Quadri, P.E-!51481 a � .. , r AMERICAN TESTING MATERIALS 0 fi RIll F• ., ENGINEERING. LLC. ;.::',,,8/0A/A.11 , s/ON^ Fk` ,"' .ht . . 0r = Tsoisawnsactetthe wady cues to Toed®ear . h Mae lia*eeruea2cm We feted tears restated an mm Den*Test amara Matra Sprwl%LLC Is must to hidiS re to Asa=hat laatedcanta diest the lWAtc r.0 amaglram di cepgOhant aaaandg;l as Iv en rdtbrtle oQee't &den rat Lfttribtan rMIpa'Jitm =ani slaty S.oradtgUitts mr salt Eon ow meets i6 nomad AMERICAN TESTING MATERIALS ENGINEERING, LLC. . Testing Laboratories-Engineering Inspection Services-Chemist-Drilling-Environmental Services 411111 1950 west 84th Street,Hialeah, Florida 33014-Phone:305-646-1888 Fax:305 Cab 1887 Field Density Test of Compacted Soils ASTM D-5195 Client Ocean Breeze,LLC Order#: 20-0220 Address: 7735 NW 146th Street,Suite#306, Miami Lakes,FL 33016 Date: 2202020 Project Ocean Breeze East Apartments-Building 2 Gauge SIN: 23082 Address: 703 N Seaaest Blvd.,Boynton Beach, FL 33435 Pion No: Mike 954 471 0256 Area: Test Number Location(s) 6 Final Lift,Building Pad(See Plan flinched) 1 7 Final Lift Building Pad(See Plan Attached) 8 Final Lift Building Pad(See Plan Attached) 9 Final Lift,Building Pad(See Plan Attached) 10 Final Lift.Building Pad(See Plan Attached) of Material: Brown sand reSittitkin I BacldID I : I Subgrade I I Base Rock Tested By: PM e Test Number 6 7 8 9 10 Depth Pig 17 12- 12' 12' 12- Fre1dDensly LB/Cu R(Dry Density) 1063 104.8 105.7 104.8 105.9 #arsine Contents 4.5 5.1 42 4.5 3.7 Maximum Density in the Reid(%) 100.6 98.6 99.6 98.8 99.8 Comrpacdam Repubement by Specs t%) 95.0 95.0 95.0 95.0 95.0 100%Maximum Density(Lab)-AASNIO T I80 106.1 10&1 1061 106.1 106.1 Opti Moisture(%) 112 112 11.2 112 11.2 Status - PASS PASS PASS PASS PASS -- Remarks: Typed By: ak i,�''' Respectfully submitted by, 0 ..,y . .1.. l•u4 ``ewe • �1GFN,S, �.. ' ç5&ctcw • ''i0. 51 i - E T - Quadri,P.E 151481 -,� h• '1'r ` AMERICAN TESTING MATERIALS Is -1.. STATE ;,F ENGINEERING. LIC. ism resicecit=cams el eye meets twosome 1� ee r4ae0 en to lib[arato�a m sante: s bemuse I pnrr an ltagai regret tit roi Pee bbe r,.Nhe erste 'R '>,l'••�• As a rthS praheclgn lrn mint ae pita sea entat al Mart are bdyemlreh aft Nine emir tee pea,oreteett erd settertatne er irailaECS,I 5aemet¢ruhhvere m efaCts tan an motes Is reseweb AMERICAN TESTING MATERIALS ENGINEERING, LLC. Testing Laboratories-Engineering Inspection Services-Chemist-Drilling-Environmental Services ITN1950 West 84th Street,Hialeah,Florida 33014-Phone:305-646-1888 Fax:305-646-1887 (`• Field Density Test of Compacted Soils ASTM D-5195 Client Ocean Breeze,LLC Order 0: 20-0507 Address: 7735 NW 146th Street,Suite#306,Miami Lakes,FL 33016 Date: 5/7/2020 Project: Ocean Breeze East Apartments-Building 2 Gauge S/N: 23082 Address: 703 N Seacrest Blvd., Boynton Beach, FL 33435 Phone No: Mike 954 471 0256 Area: Test Number Location(s) 11 Final Lift,Building Pad on kiosko in front of Bldg 2 at North 12 Final Lift.Bid ding Pad on kiosko in front of Bldg 2 at Center 13 Final Lift Balding Pad on kiosko in front of Bldg 2 at Sash rescrtp#onof Material: Brown sand F71 Bestial! Subgrade x I Base Rock Tested By. PM Test Number 11 12 13 Depth(m) Reid Density LB Cu Ft(Dry Density) 105.3 1047 104.4 Mohan Contents 4.1 37 3.8 Maxfouan Density hi the Field(SQ 992 98.7 98.4 Ccn,pacgon Requirement by Specs(19 95.0 95-0 95.0 100%Maximum Density(Lab)-AASNTO T180 106.1 106.1 106.1 Optimum Mofsbrre(%) 112 112 112 Status PASS PASS PASS Remarks Typed By. ak q`jotiii,'hnn ,,,." • ,ysubmitted by, `Nt� 5 R1 iz°z../ Waseem Quadt&a P.E.0 51481 STA RICAN TESTING MATERIALS Q ,c t NEERINC£LLC. -rf,, F . (QRIDP ,.• F� ,= We .-'M1';,r�.. -,,,....�ors .. ..,. . .a--, . T .•. ,ifl.".. . . , . �.,. .f L,-•-,., ..:.. -On OJr,. • Sam imam unit Eoaemeergt.LLC les baa r,.ao rmy`.aseidreIIlrrirlh as a e,m:M metes pp diem.tte wenn:and magma aW am=tot su6ermd as tis texedantlot paoerq•ca dint.aru4 mitoricalie fbo matt ecru o? ootorsolo mau:ltscra or atria ton can ratans rx awned 1 ' - -� - _1,frs ` 17 m ' i i , ry- iS ! 3'�y+'`•..t 4' Q atfr-a .litiwfIIA t `nI' ‘. t-- F .fr „i.-- • ` { l rt; • �!. ' ,L C_ vn - { , wq! ` $ 4 '' % ri a . ' - } i ¢ . 1s `X 444 :v' > + ' 7L, n Ihiw3 `t , ' i, , lav .H :„......, ' A ' i s ii .. 1 � 1 a 9' , E. „.4.a :,! COFi- ` t t._'r.---It„.----:----z —t: •a '4 14 t'''Oln 1 - . I�. ] I r{. - i,- 1 �. 1 14 a 4, 13 e� rpt t tai { w I , y. F9 P v ; i;. R to 1r ca t + . .. t. '' l'S? � • -S` ilii ' g I �: ,, im,:.10. .. ins , r Y . �_ 9 Q-i1 Tl•• .1. _-----?" t• . __ •tee._ -.,...--t .,..•:>: .—•{ ' " F. 'fid { tt � i " � • - \ s: fld �_ • h. 1 Lam':. , .. �_. �, �� • 1 t r �_1 \ . 1 d 1 1, � n .. .*.d., _. I "— 11i'� i; .••'1 ®.i a r. � `� " t il,W 777 } t - ‘ - L ' 11',. 1 I 1 . ill i 1 i 9; 1 .. mss g F 61. k- 1 i _ ._ `- 17. a i b i� tt. 6 ,� • 'e M z I �yt� Professional Insulators of South Florida FTC Insulation Installation Certificate To: Palm Beach County Date: July 22,2020 Re: Building 2 Address: 701 N Seacrest Blvd Project: Ocean Breeze East The undersigned hereby certifies that insulation has been installed in the above described property as follows: I. Exterior CBS walls have been insulated with: Spray-on Cellulose Thickness in inches: Fiberglass Blankets Manufacturer: Fi-Foil VR Plus Shield • Rock Wool Blankets Density: X Aluminum Foil R-Value: R-7 _ Rigid Board Polystyrene Other 2. Underside of Roof Deck have been insulated with: Spray-on Cellulose Thickness in inches: 13.8 X Fiberglass Blown Manufacturer: Johns Manville Climate Pro ▪ Rock Wool Blankets Density: Aluminum Foil R-Value: R-38 Polyurethane Open Cell SPF Applied Directly to Open Cell SPF insulated with: Spray-on Cellulose Thickness in inches: Fiberglass Blankets Manufacturer: • Ignition Barrier Density: Fiberglass Blown R-Value: Cellulose Loose Fill Open Cell SPF 3. Perimeter kneewalls have been insulated with: Fiberglass Blankets Thickness in inches: • ' Fiberglass Loose Fill Manufacturer: Rock Wool Density: Fiberglass Blown R-Value: Cellulose Loose Fill Open Cell SPF 4. Garage/House and Garage under living area walls have been insulated with: Fiberglass Blankets been insulated with: Rock Wool Thickness in inches: Polyurethane Manufacturer: Spray-on Cellulose Density: Open Cell SPF R-Value: 5. The following have been insulated: ••.•`'gnloco� RS CONSTRUCTION OF DADE, INC • �40 General Contract/Builder ;J:. pOsue � V.. SEAL 2003 . gif- t ? CGC1527092 �+O . .�O Competency# S,�'•�OrlO�`��J� Professional Insulators of South Florida,Inc. �'• a ooAoo:••`' Insulation Contractor By: By: • f :-1 ARA ENGINEERING,INC. ' ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING October 30, 2020 Building Official City of Boynton Beach Building Department 100 E. Ocean Avenue Boynton Beach, FL 33435 ,, Project: Ocean Breeze o. 100 N.E. 7th Avenue, Boynton Beach, FL 33435 N Buildings 1, 2, 3, 4, DDuump�sters, Mail Kiosk mo 0 Permit #: 19-00002946, 1' 9-00002649, 19-00002648, 19-00002647, 19-00002692, °' 19-00002950 I 0 Reference: Special•Inspectione Finale:grater E Dear Building Official: II d Per Florida Statutes 553.791(11) and•533:79(7•)(a)eel .this is to certify that this office has cm observeihe.stem.wall,monolithic SOG, footings, Iintel;.tle.beams,,columns, CMU, v reinforcing steel, structural and fire fesista cn a integ'�r`i�tyy, and fire rated penetration in concreteIab•and•drywalllandlto the best of my knowledge and•beliefrit•is•in accordance @, to the drawings approved structure.; the City ofBoyntoonn .Beach. CO If you have any_questions,,please do not hesitate to contact me. CD C Best Regards, co cp i �yp0 ARo'',, tt 0 ::Ek *. W N0. .:;0;* •STATE OF to; ',;A;,....!2omo?.•..GSA'; o,"9�0t NAL eto• Eduardo Roman PE.,SI. PRESIDENT PE 71118 ATTACHMENTS: 2020.06.09 SI Form 4 CITY OF BOYNTON BEACH DEVELOPMENT DEPARTMENT I BUILDING DIVISION 100 East Boynton Beach Boulevard•Boynton Beach,FL 33425•(561)742-6350•Fax 7424357 Special Inspector Application In accordance with Section 110 of the Oty of the Boynton Beach Amendments to the Florida Building Code the request for a Special Structural Inspector,a Florida Registered Architect or Licensed Engineer,to perform the following mandatory or discretionary inspections, as outlined In Section 110 of the Rorida Building Code. The Special/Threshold Inspector shall maintain progress Inspection reports onsite during construction, submit to the jurisdiction on a weekly basis inspections reports, and provide a Certificate of Compliance after all work is complete to the Building Official before the final inspection as per Section 110 of the Florida Building Code. Note: The Building Official shall determine which discretionary Inspections are to be delegated. Name of Project:_Ocean Breeze Permit N 19-2649,19-2648,19-2647,19-2646,19-2692 Date:6/8/2020 Project Address: 700 N.Seacrest Blvd Zip Code:33435 legal Description: PCN:08-43-45-21-00-000-0021 A. Mandatory Inspections Type: 1) Stem wall,monolithic slab on grade,footings/grade beams,pilings and pile caps. ®YES ONO 2) Lintel,tie beams,columns,masonry units,reinforcing steel and shoring. ®YES ONO 3) Structural Steel,connections,welding,bolts and anchor rods. OYES ENO 4) Smoke Control Systems. OYES SONO 5) Threshold Building(fs section 553.79(5)) OYES ENO B.Discretionary Inspection Type:Per Building Official 1) Buildings and structures of unusual design or methods of construction. OYES 19NO • Windows and doors OYES ONO • Structural and fire resistance integrity' _ _ _ 6rLYESLINQ 2) Buildings of Type I construction. OYES ONO 3) Major structural alterations. (DYES(ZNO 4) Where the concrete design is based on compressive strength in excess of 3,000 pounds per square inch. OYES ENO 5) Buildings with an area greater than 20,000 square feet. OYES®NO 6) For buildings more than 2 stories In height OYES ONO 7) Pile driving. DYES ONO 8) Private Provider. ❑Structural °Electrical ❑Plumbing °Mechanical OYES ONO 9) Other EYES ONO FIRE RATED PENETRATION IN CONCRETE SLAB AND DRYWALL C Mandatory Documentation: 1) Inspection schedule stating the specific inspection that will be made and at what phase of construction must • • ed with this application. 2) Progress report/inspection reports during construction. 3) Certificate of Compliance shall be submitted prior to the scheduling of the fin. •.i di :y Owners Panted name: Lewis Swery Permit Holders Printed Name: Lewl S 'a-tu J— ,15VARDO q Permit Holders License fr: CGC-070309 ��' LIC4 . F Special Building Inspector Printed Name: Eduardo A.Roman Signature: — ;••�8 ❑Registered Architect and/or ID Licensed Engineer 7. * i plqtioZ:› Special inspector Signature: _ _ 0 ' • ' Special inspector Address: ?4.6 NW 115th Ter,Parkland H.33076 ". '•• iO SOF •��\ State of Florida Registration a: PE 71118 i� k1 DA `fir �vpf�,'a� 4itd�id.tiata Phone:$54-jjZygyFax:=--Email eduardo@araengineering.com � ry�1177`••`�" "Omit)" *Plans for all buildings shall indicate how required structural and fire resistance integrity will be maintained where a penetration of a required fire resistant wall, floor or partition will be made for electrical,gas, mechanical,plumbing and communication conduits, pipes and systems.Such plans shall also indicate in sufficient detail how the fire integrity will be maintained where required fire resistant floors intersect the exterior walls and where joints occur in required fire resistant construction assemblies. S:iDevelopment'BUILDING1Threshold_Private Provider 2017 FomisLSpedal InSpector_Private Provider,Appfxagon.doot ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING February 21, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze N. Ct 100 NE 7'" Avenue, Boynton Beach, FL I N Permit #: 19-2947 0 Reference: Building 2 Type 2 SOG, foundation, and fill 0 Dear Builtlfficial: - - E 0 This is to certify that this o�fice has�observed theAab a reference reinforcement and it is in accordance t�pproved drawings by ARA Engineering, INC. a) c No exceptions.taken. C a) cti Best Regards, II ID „ 9%0 I/. q R0 ', \```\•Rp0 A. R it, \\‘\\ OJ�� EN'SF: yya. N �I t�•• E1L1 q-W-`V'v —.i- /NO,7. 12 co % O • STATE OF .•[V z. i^/�s jar 1 4.9` w e'S 'ONAL E `��. /toillio`` •I �''11,11,100‘ Eduardo Roman PE., SI. PRESIDENT PE 71118 11 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS • • SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 6, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N a tc‘iO Permit#: 19-00002947 cn N. Reference: BUILDING 2 HSS Colum 3m Floor ° Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in o accordance'of4he'approved'drawings by the City of BoyntomBeach. c PI No exceptions'taken. d Best Regards, . ■� © , o0 NO at)0eAmegid, o M . 1U E o e :: LU TATE OF ._ ` x C• • STATE OF xP W ��''�,1ONA1_�E�,.`• fi,,, /O6JJJAL`j`\\ Eduardo Roman PE., SI. PRESIDENT PE 71118 . riL---1 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING March 23, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N V tD Permit#: 19-00002947 Reference: BUILDING 2 3rd Floor Slab Steel Reinforcement un Dear Building Official: lift E This is to certify that this office has observed the above reference reinforcement and it is in o accordance'of4he'approvedldrawings by the City of Boynton' each. C IL No exceptions'taken. lin ■ MIC c Best Regards, ■ 111111, \\`,\R0°"A"Rt,1/ \\ 0-9,00 A"DR 7� 0. 1118////y; • E : �` (Y' E 0 . :per �• STATE OF :� (V�: --."/ "TAT ,. 3 'SS�ONAL Et\.\\ '"//ONAl. E- W ��!/71111111 \ l/11111 Eduardo Roman PE., SI. PRESIDENT PE 71118 • • . fi ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING March 20, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N V CV CV Permit#: 19-00002947 so Reference: BUILDING 2 HSS Golu' 2nd Floor in Dear Building Official: pat This is to certify that this office has observed the above reference reinforcement and it is in E accordance'ofothe'approved'drawings by the City of BoyntomBeach. IN li No exceptions'taken. is cu ■ Best Regards, ■ ■ ■ 0 p $0`totilliiy, psi • i, u • % RU JP r ceNS y. &kb. No. - illi ., • -A iiia . c * -- it m cc �pQ�•. STATE OF (V�. %� T F W '2 %��SS..tORIDP.••G, ,: --.,,S4�iF �y.03 ,_ w '1/,��NAL 1E���. g/ONA- \. Eduardo Roman PE., SI. PRESIDENT PE 71118 • ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING March 05, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze a 100 NE 7'h Avenue, Boynton Beach, FL N Permit #: 19-2947 Referenced: Building 2 -2nd FL slab o Dear Building'Official: E c This is to certify that this office has_obserrvved theaboovve reference reinforcement and it is in accordance to the drawings by ARA Engineering, INC. a No exceptions.taken. C ■� a) Best Regards, II! �p111 1'1' hI'IR ``Il pistil ` ADO A. R ® ....,142...-•I,IG N ...QI i y o.711 71 ~ ��: co STATE OF ` % (C` •'•.'°CORID P,.•• ''�; - w ":,/FS,S/OLORio G�• �'; �'SS-ONAL E?C\;�.. �� '.���� NAL11111 Eduardo Roman PE.,SI. PRESIDENT PE 71118 • ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING March 3, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N V' `° Permit#: 19-00002947 CO l Reference: BUILDING 2 FIBS Col'mun 15t Floor Li Ln cn Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in o accordance'of4he,approvedidrawings by the City of Boynton each. o cri No excep-tibns'taken. a) ■ F Best Regards, III M \``1,,iI i,,, 01111ulIIU, ,o.` 03,944 12 "N00%11110,1 DOA �,, . • . :.. 0, 111 O !pf9y *Ill :' O. 711 C Eit * _ . il E �] T Ce 0 STATE OF ::�IQ : L�Lp^T�(,(7`(l/ qF �.,/��/: Si v' fi�s`S�ONAL ��C?.� ' i, !NALtE�. Lu `/i,IIIII WI Eduardo Roman PE., SI. PRESIDENT PE 71118 7-1 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 6, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze h 100 NE 7th Avenue, Boynton Beach, FL Permit#: 19-00002947 Reference: BUILDING 2 Bond Beam~ rri Dear Building Official: 111111111 E This is to certify that this office has observed the above reference reinforcement and it is in accordance'of.the'approved'drawings by the City of BoyntomBeach. No exceptionsitaken. Best Regards, ■ N ■ ■ 0 \\ttttlltlt,it .\\, .!.. \6. 111:0120. .1111 t 001 I I I •k _ _ • .711 •. O '• STATE OF - C,,e6±0...'• ......... Cjs•‘ ?.)391/47420.n 03 orsintio . ��0,,/ONAL tE-\\ Eduardo Roman PE., SI. PRESIDENT PE 71118 --------ri . ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 18, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N a N Permit#: 19-00002947 co Reference: BUILDING 2 Roof Truss Erection Ti ° Dear Building Official: lilt This is to certify that this office has observed the truss erection and it is in accordance of the E o approved drawings•by the'City'of Boynton Beach. m c a No exceptions taken. ■ d d Best Regards, ■ 1111\` lttlutt, / ` � ' .JPR0A. RO,�io . 0A 13 Ill ,R�ID �o• '`�cN ..-,:i..4. � NfGS �• - -W.L. 1118E . �� _ * o . O STATE OF 0,1,..-:. -Tt • C' o 'ice •'•.F(ORIOp•, •'•\ am �� CO %/�S`S�•ONAL EN `�s -- /9/2 w ''�'ltllullt�` ` .,,', `Sf.ORIO•..•C'\ '', 'ONAL E�\. 1.11/1lllllttl Eduardo Roman PE., SI. PRESIDENT PE 71118 if T- ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 27, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze r— 100 NE 7th Avenue, Boynton Beach, FL N Permit#: 19-00002947 Reference: BUILDING 2 Roof Sheathing` Dear Building Official: E This is to certify that this office has observed the roof sheathing and it is in accordance of the • approved drawings•by4the'City.of Boynton Beach. 01 No exceptionsitaken. ■ ■� • Best Regards, %�Uiu.I ■ csi% ,`` �pFi:.... . p, JP. '\GEN• SF EAttivAICE • • Cr CC " • Q STATE OF •.((�` :-.7�1i{•. /TTF ' co S ONAI. E�\ ` ./ `WONAIL- ��iirrnllitl� Eduardo Roman PE., SI. PRESIDENT PE 71118 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING May 4, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL Permit#: 19-00002947 Reference: BUILDING 2 Roof Engineering ° Dear Building Official: E This is to certify that this office has observed the roof engineering and it is in accordance of the approved drawings'bydhe'City'of Boynton Beach. 0 oh a No exceptions taken. . ■ Best Regards, ■ ■ ■ v 0001111i/oil `p wdddluryl . p0 A ' J m •‘\,11.•'.....,;R �' . ``00 A. ROM ',, ;9 0 � •: gl1/4P4:412;••• ..� J�'..\\CENSE t:2.v: 714• - 'TM. E //A Jn Q STATE OF ((� / � ( {ha 6? 2 C: iCI.S1. •F(OR10 . \�� 11 \ J`cS/ONAt \\\• ''//III I11 \ Eduardo Roman PE., SI. PRESIDENT PE 71118 11 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING May 20, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze N 100 NE T" Avenue, Boynton Beach, FL N V N Permit#: 19-00002947 N. Reference: BUILDING 2 Window and door bucks 4 N . Dear Building Official: E This is to certify that this office has observed the installation of the window and door bucks and U it is in accordance'of.the'approved drawings by the City of'Boynton'Beach. :+ CO Iii No exceptionsstaken. - _ cv c cn Best Regards, N m ```11111111///// JPSog.a Ro °' CI Na m i� EE ' %-. STATE OF (V�` co ///SS�ONAl llll ti‘‘‘‘ w Eduardo Roman PE, SI. PRESIDENT PE 71118 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING June 15, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N Permit #: 19-00002947 Reference: Building 2 Fire Stopping -All Floors I aft. Dear Buildi�fficial: E ■ ■ This is to certify that this office has observed the installatio9 fire stopping per the UL assemblies listed in the permit plans approved by the City of Boynton Beach and it is in accordance of said plans. No exceptions taken. ■ ■ Best Regards, ■ �- 0 '05 ■ .- Poo • i/o co 614;017. cc • — o v gyp '. ` D Q STATE OF ((, : if /710NAL0 Eduardo Roman PE., SI. PRESIDENT PE 71118 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING June 15, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze Cg 100 NE 7"' Avenue, Boynton Beach, FL N co Permit #: 19-00002947 LO Reference: Building 2 Fire Stopping -All FloorsMalt 1=1 Dear Builtlmgefflcial: ■ ■- This is to certify that this office has observed the installatio9 fire stopping per the UL assemblies listed in the permit plans approved by the City of Boynton Beach and it is in accordance of said plans. No exceptions taken. ro Best Regards, ■ ■ 0 a ``\`ti ' aS111,, ■ ■ * No. o cc ;12 �� co STATE OF (oz. . Q �",`S"OVAL \c' 1 rrrrrulll��� • Eduardo Roman PE.,SI. PRESIDENT PE 71118 , Datv-03) SCAkmo c6 (A,4 S (CCriL ao-r, myg-4-/A LALY.v712 vrz, ec' Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2947 job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 104 NE 7th Avenue Bldg: 2 Unit: 101 SQ/FT: 1105 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 Inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406.2017(ERI): y93x 60 + 9,834 = 00 Method for[a1 ,Iatin buildinvvoblmP• CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS ❑FAIL O Code software calculated ❑When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.interlor doors,If installed at the time of the test shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,If Installed at the time of the test shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LIC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. • Signature of Tester: Wcrt-e Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute �easide Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2947 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 104 NE 7th Avenue Bldg: 2 Unit: 102 SOFT: 1105 City: Boynton Beach State: FL Zip: 33435 Alr Leakage Test Results Passing result must meet either the Performance,Prescrlptive,or ERI Method PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACEI. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI): _ x 60 + 9,834 = 3,03 methodfac akulating_buildingvolumar CFM(50) Building Volume ACF1(50) ® Retrieved from architectural plans PASS ❑FAIL O Code software calculated ❑When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSVRESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other Infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,If installed at the time of the test,shall be turned off. 6Supply and return registers,if Installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: 't 7 Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute ;/easide Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2947 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 104 NE 7th Avenue Bldg: 2 Unit: 103 SQ/FT: 709 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method 0 PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ER!: V22 x 60 + 6,310 = V 0 ( Method for calculatingbuildingvohime CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans cit_IPASS FAIL O Code software calculated ❑When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted In accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. - 3.Interlor doors,if installed at the time of the test shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: _--i e2 Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute :seaside Envelope Leakage Test Report (Blower Door Test) SERVICES Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2947 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments, Lot: Blk: Address: 104 NE 7th Avenue Bldg: 2 Unit: 104 SQ/FT: 709 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI): 7 z to x 60 + 6,310 = `/05— Method f c JculatinvbuildingvolumP- CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans ®PASS El FAIL O code software calculated ❑When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. • Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interlor doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. S.Heating and cooling systems,if Installed at the time of the test shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute Qc'asicie Envelope Leakage Test Report (Blower Door Test) E R V I C E S Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2947 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 104 NE 7th Avenue Bldg: 2 Unit: 105 SQ/FT: 709 City: Boynton Beach State: FL Zip: 33435 AIr Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air. changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERO: 1 5/ x 60 + 6,310 = 93 Method fo[ air da[Inghuildingvolume CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS El FAIL O Code software calculated When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust Intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if Installed at the time of the test,shall be turned off. 6.5upply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: `/- a Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute teaaside Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2947 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 104 NE 7th Avenue Bldg: 2 Unit: 106 SQ/FT: 709 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ER!Method PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD•The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section AO-I. ACH(SO)specified on Form R405-2017-EnergyCalc(Performance)or R406.2017(ERI): q7 x 60 + 6,310 = 'y SO Method for rah dating huildingvolume. CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS ❑FAIL O Code software calculated When ACF1(50)is less than 3, Mechanical Ventilation Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSVRESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(SO Pascals).Testing shall be conducted by either Individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond Intended infiltration control measures. 3.Interlor doors,if installed at the time of the test shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall he closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. 7 Signature of Tester: • �� - Date of Test: 10/12/2020 Imr Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute ;seaside Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach I Permit#: 19-2947 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 104 NE 7th Avenue Bldg: 2 Unit: 107 SQ/FT: 709 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form 8405.2017-Energy Cailcc((Perforrmance)or R406-2017(ERI): V i x 60 + 6,310 = /r 5? MPrhodfor calculating.huildintvolumP• CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS ['FAIL 0 Code software calculated 0 When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake-makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Intedor doors,if installed at the time of the test shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6Supply and return registers,if Installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: 7n. + Cr Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute Cy"...Nasi de Envelope Leakage Test Report (Blower Door Test) VICES Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2947 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 104 NE 7th Avenue Bldg: 2 Unit: 108 SOFT: 709 City: Boynton Beach State: FL Zip: 33435 • Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 Inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI): "y/0 x 60 + 6,310 = 5if Method for cdlculatinghuildiogvnlumP CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans %PASS ❑FAIL O Code software calculated when ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 lnche w.g.(50 Pascals).Testing " shall be conducted by either indMAduals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3Xf),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 63upply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: `/. St : � - Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 _ Issuing Authority: BPI - Building Performance Institute Qeaside Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2947 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 104 NE 7th Avenue Bldg: 2 Unit: 109 SCUFT: 1105 City: Boynton Beach State: FL Zip: 33435 Alr Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. '/ ACH(50)specified on Form R405-2017-Energy Calc(Performance)or 8406.2017(ERI): 7`V . x 60 + 9,834 . 3, O z Method forcalculatine buildingvolume• CFM(50) Building Volume ACI-1(50) ® Retrieved from architectural plans 'PASS ❑FAIL O Code software calculated When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated Installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.10S(3xf),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers Including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interlor doors,if installed at the time of the test,shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: • �t�t.—Z. Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute @Igkaside Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2947 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 104 NE 7th Avenue Bldg: 2 Unit: 110 SO/FT: 1105 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakagerate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2077(ER!):nI C241 x 60 + 9,834 = Method for calculatingluildingvolume CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS ❑FAIL O Code software calculated fl When ACH(50)is less than 3,Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth In Section 489.105(3xf),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing. 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if Installed at the time of the test.shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,If Installed at the time of the test,shall be turned off. 6.Supply and return registers,if Installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute ;/easide Envelope Leakage Test Report (Blower Door Test) ti E R V I C E o Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit #: 19-2947 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 104 NE 7th Avenue Bldg: 2 Unit: 201 SQ/FT: 1105 City: Boynton Beach State: FL Zip: 33435 • Alr Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ©PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI): _I syse x 60 + 9,834 = 3,1/ Methrid. dlmlati gbuildingvolume' CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans /x(PASS ['FAIL O Code software calculated D When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3Hf),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other Infiltration control measures. 2.Dampers Including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,If installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if Installed at the time of the test shall be turned off. • 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements accordinginngto the compliance methodselectedabove. Signature of Tester: ����'/ • = Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute Qjcaside Envelope Leakage Test Report (Blower Door Test) FF VICES Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2947 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 104 NE 7th Avenue Bldg: 2 Unit: 202 SQ/FT: 1105 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Posing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405.2017-Energy Calc(Performance)or R406.2017(ERI): 1 sys x 60 + 9,834 = 3,3Z Method for calculatinghuildingvolumP• CFM(50) Building Volume ACI-I(50) ® Retrieved from architectural plans PASS ❑FAIL O Code software calculated ❑When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted In accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either IndMduals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(,),(g).or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers Including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: �. 1 Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Loteessttoo License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute �easide Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2947 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 104 NE 7th Avenue Bldg: 2 Unit: 203 SQ/FT: 709 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI): l 5-3 3 x 60 + 6,310 = $7O6 Method for talculatinabuildingvobtmP• CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans (PASS F1FAIL O Code software calculated ❑When ACH(50)is less than 3,Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSVRESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(SO Pascals).Testing shall be conducted by either Individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3Hf),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. • 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if Installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester:_,Z . 1/ Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority:BPI - Building Performance Institute seaside Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach I Permit#: 19-2947 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 104 NE 7th Avenue Bldg: 2 Unit: 204 SQ/FT: 709 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form 12405-2017-Energy Calc(Performance)or R406-2017(ERI): 415-3 x 60 = 6,310 = 4/ 10 Method for calrulatinghuildingvolumr• CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS ❑FAIL O Code software calculated ❑When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth In Section 489.105(3)([),(g).or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test.shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,If installed at the time of the test shall be turned off. 6Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements accordingtothe compliance method selected above. Signature of Tester: G��i . �U o�G� Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute çJF'bside Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2947 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 104 NE 7th Avenue Bldg: 2 Unit: 205 SQ/FT: 709 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 Inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACI-1. ACH(50)specked on Form R405.2017-Energy Cook(Performance)or R406-2017(ERI): —I C3 z x 60 + 6,310 = J i DS. Method for caIciilatingbuildingvolurP' CFM(50) Building Volume ACH(50) Retrieved from architectural plans PASS ❑FAIL O Code software calculated when ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either indMduals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3X0,(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,If installed at the time of the test,shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6,Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. I Signature of Tester: • IS. Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute vist,oside Envelope Leakage Test Report (Blower Door Test) ERVICES Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach I Permit#: 19-2947 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 104 NE 7th Avenue Bldg: 2 Unit: 206 SQ/FT: 709 City: Boynton Beach State: FL Zip: 33435 Alr Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI):1-7 5 ex 60 + 6,310 ( Method for can datingbuildingvolumP CFM(50) Building Volume ACH(50) (� ® Retrieved from architectural plans LCIPASS ❑FAIL O Code software calculated ❑When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3Xf),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other Infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interlor doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,If installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. • Signature of Tester: • �I -. Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: _5010864 Issuing Authority: BPI - Building Performance Institute QciEe, Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2947 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 104 NE 7th Avenue Bldg: 2 Unit: 207 SO/FT: 709 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R40S-2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specgied on Form R405.2017-Energy Calc(Peerrformance)or R406-2017(ER0:f 1 571Q x 60 + 61310 = X C2 Method jpLLdl[uldtinghuilrlinvvolume. CFM(50))f Building Volume ACH(50) ® Retrieved from architectural plans ZIPASS ❑FAIL O Code software calculated El When ACI-1(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either IndMduals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g).or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterlor windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interlor doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Hearng and cooling systems,if Installed at the time of the test shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company • Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according� to the compliance method selected above. --7:,‘,-th Signature of Tester: / • Date of Test: 10/12/2020 • Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute aside Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2947 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 104 NE 7th Avenue Bldg: 2 Unit: 208 SQ/FT: 709 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 Inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calclc(Performance)or R406-2017(ERI): 6. �J x 60 + 6,310 = J / U Z Method for calrulating.buildine volume• CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans 'PASS ❑FAIL O Code software calculated ❑When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3X1),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,Intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,N installed at the time of the test,shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,If Installed at the time of the test,shall be turned off. 6.Supply and return registers,If Installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: C Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute ;seaside Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2947 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 104 NE 7th Avenue Bldg: 2 Unit: 209 SQ/FT: 1105 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(S0)specified on Form R405-2017-Energy Calc(Performance)or R406.2017(ERI): !O ZO x 60 + 9,834 = 3, 78 Method fotcalrulatinghiiildinQvnlume CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans XPASS 7FAIL O Code software calculated When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3Xf),(g).or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the Intended weatherstripping or other Infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Intedor doors,if installed at the time of the test,shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6Supply and return registers,If Installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: • tis - �. ' Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute e ;saside Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2947 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 104 NE 7th Avenue Bldg: 2 Unit: 210 SCl/FT: 1105 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ER!Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406.2017(ERP,section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405.2017-Energy Calc(Performance)or R406.2017(ERI): , 551 x 60 = 9,834 = 31 3 / MPlhodfoLcatrulatingbuildinavolume. CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans IIPASS ❑FAIL O Code software calculated 0 When ACH(50)is less than 3,Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other Infiltration control measures. 2.Dampers Including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 65upply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: 10/12/2020 • Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute QSeaside Envelope Leakage Test Report (Blower Door Test) ERVICES Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach I Permit #: 19-2947 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 104 NE 7th Avenue Bldg: 2 Unit: 301 SO/FT: 1105 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ER!Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. J ACH(50)specified on Form R405.2017-Energy Calc(Performance)or R406-2017(ERI): /` L� G ? x 60 + 10,276 = 3, iC M4rhndfor cafulatingbuildingvolumP• CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans I,PAS$ 17FAIL O Code software calculated When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted In accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3Kf),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interlor doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,If installed at the time of the test,shall be turned off. • 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. N-0361 Signature of Tester:_74. Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute ;/easide Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2947 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 104 NE 7th Avenue Bldg: 2 Unit: 302 SQ/FT: 1105 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. 2ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI): 7/3 x 60 = 10r276 = Method foccaUnlatingbuildingvoblme• CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS FIFAIL O Code software calculated C When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3Xf),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. S.Heating and cooling systems,if installed at the time of the test shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: _954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. ,G%v/Signature of Tester: • � .r Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute :/easide Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2947 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 104 NE 7th Avenue Bldg: 2 Unit: 303 SQ/FT: 709 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing result must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specied on Form R405-2017-Energy Calc(Performance)or R406.2017(ERI): J� b x 60 + 6,594 = 5, / O method fQtsalculatipgbodingvolumP• CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS ❑FAIL O Code software calculated 0 When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted In accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either IndMduals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3gf),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the Intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,Intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interlor doors,if Installed at the time of the test,shall be open. • 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,If Installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: �� �� ..i t Date of Test: 10/12/2020 lorr Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute • :seaside Envelope Leakage Test Report (Blower Door Test) SERVICES Residential Prescriptive, Performance or ERI Method Compliance 20'17 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2947 job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 104 NE 7th Avenue Bldg: 2 Unit: 304 SQ/FT: 709 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI): ySZ x 60 + 6,594 = 4 // sthnd for calculating buildingvokime CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS ❑FAIL O Code software calculated When ACH(50)is less than 3,Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted In accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f).(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the Intended weatherstripping or other Infiltration control measures. 2.Dampers including exhaust Intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond Intended infiltration control measures. 3.Interior doors,if installed at the time of the test shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. S.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company • Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: • al Date of Test: 10/12/2020 Mir Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute :/easide Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2947 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 104 NE 7th Avenue Bldg: 2 Unit: 305 SCUFT: 709 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. / 9 ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI): L " 3d x 60 + 6,594 = 3, / Method for calculatingbsildingvolumP CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS ❑FAIL O Code software calculated When ACH(50)is less than 3,Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted In accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(0,(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterlor windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other Infiltration control measures. 2.Dampers including exhaust.Intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interlor doors,If Installed at the time of the test,shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. S.Heating and cooling systems,If installed at the time of the test,shall be turned off. 6.Supply and return registers,If installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: . Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute aaside Evelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach I Permit#: 19-2947 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 104 NE 7th Avenue Bldg: 2 Unit: 306 SO/FT: 709 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ` ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERO: 7/ Y6 x 60 + 6,594 .10--C- Method for calculatingbuildingvolumP CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS I (FAIL O Code software calculated ❑When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3X0,(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the Intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,If Installed at the time of the test,shall be turned off. 6.Supply and return registers,if Installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. / Signature of Tester: 10/12/2020 I/• �� /ice Date of Test: Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute :seaside Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2947 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 104 NE 7th Avenue Bldg: 2 Unit: 307 SQ/FT: 709 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-20I7-Energy Calc(Performance)or R406-2017(ER!: 6 79x 60 + 6,594 = Cr/ 7 Method foccaifulatinghuildingvolumP• CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS ❑FAIL O Code software calculated ❑When ACH(50)is less than 3,Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either IndMduals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 439.105(3)(f),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code officio!.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterlor windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond Intended infiltration control measures. 3.Interior doors,if installed at the time of the test shall be open. 4.Extenor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test shall be turned off. 6.Supply and return registers,if Installed at the time of the test shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: ` o Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute Qeaside Envelope Leakage Test Report (Blower Door Test) VICES Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2947 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 104 NE 7th Avenue Bldg: 2 Unit: 308 SQ/FT: 709 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. /ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERO: 6 'V x 60 + 6,594 =_Cf_eni wthodfor.calculating.buildinvvolnmP. CFM(50) Building Volume ACH(50) Retrieved from architectural plans CPPASS FIFAIL O Code software calculated ❑When ACI-l(50)is less than 3,Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond Intended infiltration control measures. 3.Intedor doors,if Installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. S.Heating and cooling systems,if Installed at the time of the test,shall be turned off. 6Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according ttoo the compliance method selected above. Signature of Tester: _`%fines/ • ,Ze Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute C4Naside Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2947 • Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 104 NE 7th Avenue Bldg: 2 Unit: 309 SO/FT: 1105 City: Boynton Beach State: FL . Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding . the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. '/ACN(50)specified on Form R405.2017-Energy Calc(Performance)or R406-2017(ERQ: 6 aT 7 x 60 + 10,276 = /0�� Method for caitulating.buiidingvolume• CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans EXIPASS El FAIL O Code software calculated 0 When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted In accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducing the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the budding thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers Including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond Intended infiltration control measures. 3.Interior doors,If Installed at the time of the test.shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Suppiy and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: • is Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute • easde Envelope .Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2947 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 104 NE 7th Avenue Bldg: 2 Unit: 310 SOFT: 1105 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing result must meet either the Performance,Prescriptive,or ER!Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI):F-1 73Z x 60 + 10,276 = z 7 Method for calculatingbuildingvolume• CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS ❑FAIL O Code software calculated When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted In accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3pf),(g),or(Dor an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interlor doors,If Installed at the time of the test,shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. S.Heating and cooling systems,if installed at the time of the test shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: �. .1+Z-Cv Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute