CERT OF OCCU
Professional Insulators of South Florida FTC Insulation Installation Certificate To: Palm Beach County Date: August 18,2020 Re: Building 3 Address: 701 N Seacrest Blvd Project: Ocean Breeze East The undersigned hereby certifies that insulation has been installed in the above described property as follows: 1. Exterior CBS walls have been insulated with: Spray-on Cellulose Thickness in inches: Fiberglass Blankets Manufacturer: Fi-Foil VR Plus Shield • Rock Wool Blankets Density: X Aluminum Foil R-Value: R-7 Rigid Board Polystyrene Other 2. Underside of Roof Deck have been insulated with: Spray-on Cellulose Thickness in inches: 13.9 X Fiberglass Blown Manufacturer: Johns Manville Climate Pro Rock Wool Blankets Density: Aluminum Foil R-Value: R-38 • Polyurethane Open Cell SPF Applied Directly to Open Cell SPF insulated with: Spray-on Cellulose Thickness in inches: Fiberglass Blankets Manufacturer: Ignition Barrier Density: Fiberglass Blown R-Value: Cellulose Loose Fill Open Cell SPF 3. Perimeter kneewalls have been insulated with: Fiberglass Blankets Thickness in inches: • Fiberglass Loose Fill Manufacturer: Rock Wool Density: • Fiberglass Blown R-Value: Cellulose Loose Fill Open Cell SPF 4. Garage/House and Garage under living area walls have been insulated with: Fiberglass Blankets been insulated with: Rock Wool Thickness in inches: ▪ Polyurethane Manufacturer: Spray-on Cellulose Density: Open Cell SPF R-Value: 5. The following have been insulated: ,, •�`��bcoi•.GQ RS CONSTRUCTION OF DADE,INC :at:*• • RFORAT rOm General Contract/Builder jJ ' s� F• ' • SEAL ef CGC1527092 y•• 2003 :• 1` Competency# p •!C1or1as•-• 4- Professional Insulators of South Florida, Inc. ,�'',Oaa lonlA\�‘� Insulation Contractor By: By: D/L/SEN _ 1 -800-D!LeGENT TERM/TESERI//CES . 11 MyDiligent.com CALL DILIGENT FOR• State License J8228623 Building together, Growing Together' CONCRETE WASHOUT! Notice of Preventative Treatment for Termites I ' / /z(asZg�reguired by Florida Building Code 2326.52and Broward County Chapter FBC 105.2.2) SERVICE ORDER NUMBER -I 7quSERVICE DATE 3- v- 2U__ TIME Sa16 WEATHER CONDITIONS C I ec .r DEVELOPMENT NAME(PROJECT) CONTRACTOR'S NAME CONTACT PERSON Cxeco 6y-roe e i- 91cfE3 Phcitv.r guG i&tn OScc(r STRUCTURE ADDRESS(LOT/BLOCI CITY,STATE.ZIP CODE COUNTY /6U A/€, De/it 71"" Avc, , De/ n Bect. tk c , Ft, 33935 CONTACT PHONE NUMBER NOTES 7 , zt ?..) '�,- 757- n2�z 5 [G TREATMENT TYPE/AREA 0 FLOATING S1 MONOLITHIC 0 PATIO ❑GARAGE 0 DRIVEWAY 0 STEM WALL ❑ADDITION 0 CUTOUTS 0 FOOTERS 0 FRONT ENTRY 0 EXTERIOR PERIMETER FOR RENEWAL 0 OTHER TREATMENT�� TYPE 7//DAMP&TREAT 0 TREAT ONLY 0 FINAL 0 RETREAT 0 BORA CARE TREATMENT 0 TERMITE BAIT STATION PRODUCT AL 0 RPREMISE INGREDIENT -Y fnit L D CONCENTRATION ��y!lyyy ('�I 0.05% 0.06% py.l% 0.12% 0.25% 0OTHER GALLONS APPLIED /S� •'ERM1_TEsepp,•` . c , ICI P SQUARE FOOTAGE LINEAR FOOTAGE i iii 0 P 9 s`F� ` �!• t if SQUARE��� FOOTAGE VERIFIED ��'//`6ES •0 NO 0 MEASURED OR VERIFIED PER PLANS ' e / % JOB READY CONDITIONS MET • ' 7qES 0 NO DETAILS SAFETY CONDITIONS 600 A As per 2326.5 FBC-II soil chemical barrier method for termite prevention is used.Final exterior treatment shall be completed prior to final building approval_ Certificate of Compliance:The building has received a complete treatment for the prevention of subterranean termites.Treatment is in accordance with rules and laws established by the Florida Department of Agriculture and Consumer Services.(Per the Florida Building Code.) If this notice is for the final exterior treatment,initial and date this line (TERMITE MONITOR INSTALLED 0 YES 0 NO) FINAL STICKER 0 ELECTRICAL PANEL 0 WATER HEATER OTHER Payment Terms: Customers payment in full is due at time of initial service.Customer agrees that a finance charge in the amount of 18%per annum will be assessed on all unpaid balances that are no satisfied by the due date. In the event a collection process becomes necessary to recover an unpaid balance the following fees will be assessed in. uding but not limited to: collection service fee,attorney's fee,finance charges and non-sufficient funds payment fee. Customer`1will be responsible f• paying all cos- associated with any collection process. 1 7r J-) [ I ��- , Date Applicato (Dille rvi -s) 3-S- 2-0 Date 7.i �' ` Customer ' .perly •wn� `1 Corporate 3500 N Boca Raton BlBlvd. I Suite 1714 I Boca Raton, Florida 33431 I 1-800-DILIGENT I mydiligent.com OF.LIGElit. 1 -soaDILIGENT ESERY/Ce •♦ MyDiligent.com CALL DILIGENT FOR State License JB228623 Building Together, Growing Together CONCRETE WASHOUT! I Notice of Preventative Treatment for Termites (as required by Florida Building Code 2326.5 and Broward County Chapter FBC 105.22) SERVICE ORDER NUMBER 183349 SERVICE DATE 11/04/2020 TIME 12.05pm WEATHER CONDITIONS Clear DEVELOPMENT NAME(PROJECT) CONTRACTOR'S NAME CONTACT PERSON OCEAN BREEZE EAST Bldg#3 PHORCYS BUILDERS Oscar STRUCTURE ADDRESS(LOT/BLOCK) CITY.STATE,ZIP CODE COUNTY 100 NE 7TH AVE BOYNTON BEACH, FL 33435-3807 PALM BEACH CONTACT PHONE NUMBER NOTES 305-549-8834 Final Termite Treatment and Certificate TREATMENT TYPE/AREA U FLOATING B MONOLITHIC 0 PATIO O GARAGE O DRIVEWAY 0 STEM WALL B ADDITION 0 CUTOUTS 0 FOOTERS U FRONT ENTRY •EMERIOR PERIMETER FOR RENEWAL U OTHER TREATMENT TYPE O TAMP s TREAT 0 TREAT ONLY •FINAL 0 RETREAT U BORA CARE TREATMENT O TERMITE BAIT STATION PRODILO )OMINION O ADONIS 2F 0 PREMISE U DEMON TC O TERMIDOR 0 BORACARE B OTHER ACTIVE INGREDIENT tmidadoprid CONCENmATIQN 0.05% 0.06% 0.1% 0.12% 025% BOTHER_ GALLONSAPPUED 4SS •otAITESe-.e SQUARE FOOTAGE 9094 ;all,P p•0 H•,`,Ct,v LINEAR FOOTAGE ,•M10••0 q.��IP,s, I r SQUARE FOOTAGE VERIFIED Via % do i P l • YES 0 NO B MEASURED OR VERIFRD PER PLANS � Q' • \ O_R \.% •: • JOB READY CONDITIONS MET �.• i !ES ONO DETAILS ...- $AFEIY CONDmOtIS goodconditions • As per 2326.5 FBC-If soil chemical barrier method for termite prevention is used.Final exterior treatment shall be completed prior to final building approval. Certificate of Compliance:The building has received a complete treatment for the prevention of subterranean termites.Treatment is in accordance with rules and laws established by the Florida Department of Agriculture and Consumer Services.(Per the Florida Building Code.) If this notice is for the final exterior treatment,initial and date this line 11/04/2020 HC (TERMITE MONITOR INSTALLED B YES 0 NO) FINAL STICKER O ELEC RiCAL PANEL NATER HEATER OTHER Payment Teets: Customer's payment in full is due at time of Mal service.Customer agrees that a finance charge In the amount of 18%per artmmt will be assessed on all unpaid balances that am not satisfied by the due date. In the event a collection process becomes necessary to recover an unpaid balance the following fees will be assessed Including but not limited to: collection service fee,attorney's fee,finance charges and non-sufficient funds payment fee. Customer will be . -ng,, oats associated with any collection process. 11/04/2020 DL D, ate .:,. Services) Date Customer(Property Owner or Agent) 3500 NW Boca Raton Blvd. I Suite 714 I Boca Raton, Florida 33431 I 1-800-DILIGENT I mydiligent.com • INSPECTION LOG ARA Engineering,INC Lic.No 71118 Eduardo Roman Inspector: PE.,SI Building City of Boynton Beach Building Department-3301 Official Quantum Blvd-Boynton Beach,FL,33426 General Contractor: RS Construction Ocean Breeze-100 NE 7th Ave,Boynton Beach, Project Florida Permit$1 19-00002948 PCN 08-43-45-21-10-001-0010 Reference: Buildings 3 Inspection log detail Inspection Date Inspection g Type of Inspection Comments PASSED Approving Signature 3/8/2020 1010 Footer c tiery„,„ 3/8/2020 1020 Foundation3/8/2020 1030 SOG steal reinforcement 3/24/2020 1100 First Floor=Vertical Steel Column `�Reinforcemnt Filled Cell / G'7 3/24/2020 1110 First Floor=011 cell inspection , +1?-. ..tf77 3/27/2020 1030 Second Floor: Slab steal reinforcement 1, V 4/7/2020 1100 Second Floor=Vertical Steel Column ` �• Relnforcemnt Filled Cell 4/7/2020 1110 Second Floor=fill cell inspection 4/9/2020 1030 Thrid Floor: Slab steal reinforcement • ii) 4/20/2020 1100 Thrid Floor=Vertical Steel Column iP, Relnforcemnt Filled Cell �/1 4/20/2020 1110 Thrid Floor a fill cell inspection f7 j, 4/22/2020 Bond Beam {{{��1 5/2/2020 1400 Roof Truss erection q/ e 5/14/2020 1450 Roof Sheathing Ir Of 1-2Q--�� 1460 Roof Engineering Bracing ��h//////��1 1� v-)"'2 10 1475 Window Buck and letter �y . . ET ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING May 2, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze N. 100 NE 7th Avenue, Boynton Beach, FL N Q `° Permit#: 19-00002948 Reference: Building 3 Roof Truss Erreection 4( 1100 N Dear Building Official: E This is to certify that this office has observed the truss erection)and it is in accordance of the o approved drawings'bythe6ity'of Boynton Beach. a01C et, No exceptions•taken. m C . C Best Regards, m 0 ■�o Betioif/ `I IIII, m . . •R. o+, m ` 4 : * No. _ ■ - ' /4, a.711,1 m _ E Cr; m �, C7 K '�Q STATE OF : Ciz �17 /S 7E Co 'i s .... U' \� ;`CSS ... RIDP.•••���� w /�i;/ANAL IE �` i,ZONAL 'N\`\ lIIIIIIII\ Eduardo Roman PE., SI. PRESIDENT PE 71118 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING May 4, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N Cr Permit#: 19-00002948 id Il cn Reference: Building 3 Roof Enginee ng - �1 W U N co Dear Building Official: E This is to certify that this office has observed the roof engineering and it is in accordance of the approved drawings'by.the'€ity.of Boynton Beach. m C a No exceptions'taken. coC m Best Regsards, u lJ " 1, 11 ,, ,, ``�,t t l t u t�,,, ..��R,pO.AnR� ocENse-•27 a) * . 71118 * �11J' .r _ - • ' — CC 14/ ¢ i9 -• STATE OF • .0c- i j (,. `1'L •` �'V: • W �� SsioNALtE,G• ���nI NALEN\`' Eduardo Roman PE., SI. PRESIDENT PE 71118 • ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING May 14, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze N. 100 NE 7(h Avenue, Boynton Beach, FL N N up Ni Permit#: 19-00002948 Reference: Building 3 Roof Sheathing 1 199) 4 l ° Dear Building Official: ab E This is to certify that this office has observed the roof sheathing and it is in accordance of the o approved drawingslby.the'City.of Boynton Beach. c a▪ No exceptionsltaken. cIII • Best Regards, ■ ■� o ```,11111111��� ■ o a.ID + R � io Q.•''41G N % V? CENSF•9 +'. 64:0410. :� ..7.1.178 .:• Ce ,�O STATE OF g / t '•Coz.41 Z . .. ` a /��'SS�ONAL ENG : -, /k)61 ..�RIOA•.AC9 \N: Milln1110. ',,CONAL E 4,o' 11111111 Eduardo Roman PE., SI. PRESIDENT PE 71118 • f A • ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING March 24, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7'h Avenue, Boynton Beach, FL CN V' CO Permit#: 19-00002948 N Reference: Building 3 HSS Column 1� 5'_ F=4 Ij 00 Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in o accordance'of•the.approved"drawings by the City of Boynton each. a No excep-tions.taken - N1111 Best Regards, CO \ \ \uur1Jrrri ■ \\,al.mAl amrr17 \\ R�� A. Ri �Q0 RO\ JP .0.it, !q' ' F a) Co • / J o* .Sivoil .-3, � .,..7111 1 _ • o CC .. Co STATE OF Q -'d / .: v :- *(<` F<ORIOP.•'•• \_� tQ '. +, TATE OF • �7 ca /te, S ONAI \` 'LIJ //r/S1ONAV-\\ \\\\ Eduardo Roman PE., SI. PRESIDENT PE 71118 . . r-- -------i ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 7, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze N. 100 NE 7th Avenue, Boynton Beach, FL NI V Permit#: 19-00002948 DI Reference: Building 3 HSS Column 2"d Floor 4 1100 e — N ° Dear Building Official E This is to certify that this offit a has observed the above reference reinforcement and it is in accordance.of4the.approvedldrawings by the City of Boynton�Beach. cn I No exceptions'taken. ' - III 1.1 CD ti] Best Regards, cli j tititatit• No. - Cr cc -' STATE OF (oz. \. /ST 2 iT�` -'•.jP•(ORIO F'. '-G,\ � �` '•:c(ORION ••••. �NN CO 10 �'�`S70NAL EtJ\\ //7 , `HONAL EN 'L 1j11/Iii10 0 /ii/11111111\0\\ Eduardo Roman PE., SI. PRESIDENT PE 71118 . • ri . ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 20, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze N. 100 NE 7th Avenue, Boynton Beach, FL N Q co Permit#: 19-00002948 Reference: Building 3 HSS Column 3rd Floor 414100 in cn Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in 0o accordance'of.the'approved"drawings by the City of Boynton'Beach. ch Z No excep'tions•taken. 1' d Best Regards, �tIrIII,,�, ■ oolilll „I a O ,lc N 'Ify2 \ C`,,,-- ENSF •.yjy` Q.,,,-- a) 45)...• : g,/�/�.. * * 7111 �. N0. r� yas/ice �.-.1 V W Q L�� 2 c '•:, STATE OF •(y:: � 5T/rrE�F" �<U E '•—e( •'•.Pt ORIDP•• •••... %. �i� • .'CCORID?•.•' 0:s,' co '�;''r`S� E�`��\\ /,''SS�ONAL \4, \': - ,,ONAt_ �N �m1IIitoo '�i IIIII III``` Eduardo Roman PE., SI. PRESIDENT PE 71118 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 22, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N Q co Permit#: 19-00002948en I r op N. Reference: Building 3 Boeam Dear Building Off—ciaal E This is to certify that this office.has observed the above reference reinforcement and it is in o accordance'of'the'approvedldrawings by the City of BoyntornBeach. cio No excep"tions•taken. Na ■ ■ d Best Regards, . ■— 2 N o \`11111111/,i/, • ■ �. �-�. �`•.\Jp..A:'TO/o, �O A:ROS m ` Q .•' 1,1C N •..92�� ....5,.449„... LICENS�c ' .;9��.. No. pI NR ' • /IIII �. 71118 r/�/7 o On'. •• F ;..F 'e ••• - A\ .• ECORID?..•'G\��: 12 'i � .,.(GRID.,..•' � : ii\' ��'S`SiONAL EAG �� SAO L E�` ra S W '`'+,rin 11111` ,,�, NAILII 11\ Eduardo Roman PE., SI. PRESIDENT PE 71118 . . '\ f--.. A ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING March 24, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze N. 100 NE 7th Avenue, Boynton Beach, FL N 7 `° Permit#: 19-00002948 Reference: Building 3 Fill Cellsa151 Floor 3 no Ifts Dear Building Official: E This is to certify that this offipe has observed the above reference reinforcement and it is in o o accordance'of•the'approved'drawings by the City of Boynton.Beach. Ot 111 dNo exceptions'taken. c co ID Best Regards, III 11. ■ CO .• QJ• oc N '•' 4.%c. ■ per\ \�Ptryj N.S yr. * : No. /+ 71.11 �c - O :LU 35? -1 ce L • STATE OF !0 � • `S ATE OF at w t'S`IONAL_tENG�\ '/,''%c&S/ONAtt\-40\ ''h!IIIlnl`` Eduardo Roman PE., SI. PRESIDENT PE 71118 E-- A ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 7, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N Q N Permit#: 19-00002948 en Reference: Building 3 Fill Cellsr2nd Floor -44 1(0 lilt in cn Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in o accordance'of•the'approved'drawings by the City of Boynton•Beach. ci PI d No exceptions'taken. C Best Regards, Ill ■ 0 \\\1111111/,,t, . \ \11111111 • 1,01•A• b44 \,.``P ' 9 A. 'c'o' ■ oo• PE9......'.•Roy .c o ENSF v \,\C N V..: i IIIIIMar .W _ * N0. �1' • _ / • 71178 c _ - /- o o ;Oma'. STATE OF ((7` „ll �� v i F ••.;hIORIDP,. ' ��: ''�i•%. '•. PLOR\0?'.•' C7 � w /��'SS��NALIE�G�. %i,`Si�NAL�? �. Eduardo Roman PE, SI. PRESIDENT PE 71118 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 20, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL Permit#: 19-00002948 1110 Reference: Building 3 Fill Cellsr3rd Floor -44- ° Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in • accordance'ofithe'approved•drawings by the City of BoyntomBeach. PI No exceptions'taken: ■ ■Best Regards, �tt111111I II ,_p.,. III,II n Q 41C N ''. .045)!.,..•"�CENSFa.r - * No. ' _ � ✓! '. � 1118 * —_ C �/��,/,{�,, - • y' •• co rte . . - [C :57( IOV CSC/` T K o Q" •. STATE OF !(j . STA E E %fit9.'•.!c(ORIOP.•'•G\ : '�e('‘ •'..FLORID?'. ' �,\�� w '1.S1°NALt�N`�• SS�ONAL�?`� Eduardo Roman PE., SI. PRESIDENT PE 71118 ill its ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING May 20, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze ,. 100 NE 7th Avenue, Boynton Beach, FL N fO Permit#: 19-00002948 Reference: Building 3 VViindow,and door bucks —II *Ili 7,f ., v Dear Building Official: E This is to certify that this office has observed the installation ofithe window and door bucks and o it is in accordance�of.the'approved drawings by the City of•BoyntomBeach. cil j dNo exce IN ns'taken. cm Best RegIffards"'"" _ (10 `��iunl,�,,, aiimilmm- . : £ fl :2;H= :L==w:I .�Q ...• STATE OF 4/:. ix •„,e410..."FLORIOP, •.• �_� ,,6NAL`EN.". ov w Eduardo Roman PE, Si. PRESIDENT PE 71118 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING March 8, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze N. 100 NE 7th Avenue, Boynton Beach, FL N cr `°rsi Permit#: 19-00002948 !# 10 t 0 r Reference: Building 3 SOG, foundation, and fill cells 4*b I ci Ln t} Io3D co Dear Building Official: This is to certify that this office has observed the above reference reinforcement and it is in E o accordance'of'the'approved!drawings by the City of Boynton•Beach. II 4, No exceptions'taken. IIMIIIIIIc ■ Best Regards, I (� , \ p0 A. R ' * No. c * - - m _ ce 0 • STATE OF ` a i*� '•.!C(ORIDP'. ' •,,.....\ N., O • STATE OF ((/� w �'�rlrnll„��IONAL 1..` ''SSIONA�t�?`� Eduardo Roman PE., SI. PRESIDENT PE 71118 li- ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING March 27, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 71h Avenue, Boynton Beach, FL N Tr co Permit#: 19-00002948co .pj� Reference: Building 3 2nd FloorrSlab Steel Reinforcement -fT �Q30 v N co Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in o accordance'of4the'approvedldrawings by the City of Boynton'Beach. II No exceptions'taken. c 't Best Regards, -- `,1111 1111// ■ 111111111/1 o `0 III \��\—��i,,, No. _ _ 71 _ o o 0�'.• STATE OF • to:: ;' STATE OF . [[/ -2 „7 '•.F[ORIOP•.•' \ N 'n '•. F[ORl0 P.•' S�, W �II/SIONM: -0\` co ''/ S�ONAL �?` //[/111111\1°\ Eduardo Roman PE., SI. PRESIDENT PE 71118 is :it! Immo —. ■1= ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 9, 2020 Building-Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze a. 100 NE 7th Avenue, Boynton Beach, FL N N Permit#: 19-00002948 N. Reference: Building 3 3rd FloorrSlab Steel Reinforcement+ 4+103O a N ° Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in o accordance'ofdhe.approved'drawings by the City of Boynton'Beach. 1/1 r_ No exceptions•taken. on ingnimmiTh Best Regards, ■au au ■� 0 11II1111/ 1111 ",1111111, / / * : 1{/1/$ I +tea N 1118 o Emily No. _ --4164 • : d . -A/�.• _. . .��_ C13 o ST °b 4 // w ///IIIIIA1111 %``` +IIIII U Eduardo Roman PE., SI. PRESIDENT PE 71118 CO CHECKLIST Permit: 19-2948 Address: 106 NE 7TH AVE BLDG 3 Date:11/12/2020 PCN:08434521100010010 Build Elect Plumbing Mechanical Site Lighting Irrigation 11/12/2020 11/05/2020 10/09/2020 10/21/2020 Fire Low Voltage Gas Hood Paving Landscaping 11/12/2020 11/05/2020 Roof Fire Alarm Fire Sprinkler Fire Supp Drainage ENGN Final 06/10/2020 11/10/2020 11/10/2020 Req Sat NOTES Outstanding X Revisions Outstanding X Permits Tie-in / Form X Board Survey ,/ Final Survey X1 Soil Treatment X✓ Certificate Soil Density Rep / Piling Cert Insulation Certificate X ✓/ Elevation V Certificate XL/ Approved Bye fr \�P V Threshold / Cert lnsp Cert X / Reference Statues 553.791(11) & 533.79(7)(a) ✓ Blower Door Test X Required if application date is after 7/1/2017 Interim Fire X Rescue Fees • Public Art Fee Zoning Final Approved By: CO °Y Approved By: vecv S:\Development\BUILDING\Intake Helpful Information\CO Checklist(New)\CO Checklist(NEW).doc(10/05, 1/06,3/06,8/08, 12/08) 9/18/2020 Ocean Breese Apartments CO Request-Alex Vega Ocean Breese Apartments CO Request . Remy, Svon <RemyS@bbfl.us> (2) I (36 Thu 8/13/2020 12:05 PM To:Alex Vega <avega@centennialmgt.com>; g 1 attachment (44 KB) CO Checklist(NEW).doc; Hey Alex, This is what I want to talk to you about... Since you are almost done with the job I know you guys are going to request some Certificate of Occupancy. I am going to send our checklist for a CO. Which is what my Building Official is looking for. Now here where the issue is going to start happening. All the inspections Documents we are going to need them for each building. • Tie-in/form Board rvey— �{ • Final Survey — • Soil Treatment Certific C9/ • Soil Density Report— // • Insulation Certificate— 16-6 • Elevation Certificate( Before and After Constr on. With picture and in color)— L9� • Threshold/Special lnspfor Certificate — • Blower Door Test— Now I know a lot of these documents was on site and CAP may have picked them up. But we do not have anything. Call me if your confused or need some help. G;Y 1::>•• Svon Remy • \ Application Technician ��f/ Development, Development Services j = Mailing Address: P.O. Box 310 I Boynton Beach, Florida 33425 Physical Address: 100 E. Ocean Ave. I Boynton Beach, Florida 33435 0 h 6P ` 561-742-6283 TpN 9 RemyS@bbfl.us I ® boynton-beach.org/ 1$100YearsintheMaking Follow us on © i ®• Please be advised that Florida has a broad public-records law and all correspondence to me via email may be subject to disclosure.Under Florida records law, email addresses are public records. Therefore,your e-mail communication and your e- mail address may be subject to public disclosure. haps://mail.centennialmgt.com/owa/#viewmodel=ReadMessageltem8ltemID=AAMkADIlYjM3NzJkLWQ l YmYlNDU5Yy04NzIOLTQ1 OWMzNzE1 YjlxYg... 1/2 ___ ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING October 30, 2020 Building Official City of Boynton Beach Building Department 100 E. Ocean Avenue Boynton Beach, FL 33435 Project: Ocean Breeze N. a 100 N.E. 7'h Avenue, Boynton Beach, FL 33435 N Buildings 1, 2, 3, 4, Dumpsters, Mail Kiosk - N Permit #: 19=00002946,19-00002649, 19-0000264.8,'19-00002647,19-00002692, ° - ' 19-00002950 i l i .1 • i D Reference:-Special-Inspection-n,Final CO letter = = I E . I u i i '1 1 o Dear Building-Official:-. - ' o I ,. -- - - --- -- --- 1 'i C Per Floridd Statutes 553.791(11) and-533.-79(7)(a);=this is to certify that this office has observed the stem.wall,-monolithic SOG, footings, lintel,.tie.beams, columns, CMU, d reinforcing steel, structural and fire resistance-integrity, andifire rated penetration in concrete slab and drywall, and to the best of my-kno*led9e and belief; itis in accordance cO to the drawings approved by the City of Boynton Beach. , f — i - [ . _ : If you have any-questions, please do not hesitate to contact'me. - _- _ _ _ __ i c Best Regards, 0 \`,55111111,,,, cc `.‘JPRp° .'4? "., wNo. _ aA CC - ye •. STATE OF (yam t'SS/DNAL 5E ��‘\ Eduardo Roman PE., SI. PRESIDENT PE 71118 ATTACHMENTS: 2020.06.09 SI Farm CITY OF BOYNTON BEACH - DEVELOPMENT DEPARTMENT ( BUILDING DIVISION - o r+ 100 East Boynton Beach Boulevard•Boynton Beach,FL 33425•(561)742-6350•Fax 742-6357 Special Inspector Application In accordance with Section 110 of the City of the Boynton Beach Amendments to the Florida Building Code the request for a Special Structural Inspector,a Florida Registered Architect or Licensed Engineer,to perform the following mandatory or discretionary inspections, as outlined in Section 110 of the Florida Building Code. The Special/Threshold Inspector shall maintain progress inspection reports onsite during construction, submit to the jurisdiction on a weekly basis inspections reports, and provide a Certificate of Compliance after all work is complete to the Building Official before the final inspection as per Section 110 of the Florida Building Code. Note: The Building Official shall determine which discretionary inspections are to be delegated. Name of Project:_Ocean Breeze Permit it 19-2649,19-2648,19-2647,19-2646,19-2692 Date:6/8/2020 Project Address: 700 N.Seacrest Blvd Zip Code:33435 Legal Description: PCN:08-43-45-21-00-000-0021 A. Mandatory Inspections Type: 11 Stem wall,monolithic slab on grade,footings/grade beams,pilings and pile caps. ®YES ONO 2) Lintel,tie beams,columns,masonry units,reinforcing steel and shoring. ®YES ONO 3) Structural Steel,connections,welding,bolts and anchor rods. OYES ENO 4) Smoke Control Systems. OYES ONO 5) Threshold Building(Es.section 553.79(5)) OYES ONO B.Discretionary Inspection Type:Per Building Official 1) Buildings and structures of unusual design or methods of construction. OYES EINO • windows and doors OYES ONO • Structural and fire resistance integrity' @YES ONO 2) Buildings of Type I construction. OYES ONO 3) Major structural alterations. OYES(r]NO 4) Where the concrete design is based on compressive strength in excess of 3,000 pounds per square inch. OYES®NO 5) Buildings with an area greater than 20,000 square feet OYES(3NO 6) For buildings more than 2 stories in height DYES ONO 7) Pile driving. DYES ONO 8) Private Provider. ❑Structural ❑Electrical ❑Plumbing ❑Mechanical OYES ONO 9) Other. DYES ONO FIRE RATED PENETRATION IN CONCRETE SLAB AND DRYWALL C. Mandatory Documentation: 1) Inspection schedule stating the specific inspection that will be made and at what phase of construction must •- -b ed with this application. 2) Progress report/inspection reports during construction. 3) Certificate of Compliance shall be submitted prior to the scheduling of the fin l.b i diol n jr o• Owners Printed name: Lewis Swery S�ignaarrE ' ,, " \\1 t 1 I I I t i r i 1 /St Permit Holders Printed Name: Lewis Swear gnatu -- ;\‘` UAIIDO .4 Permit Holders License p: CGC-Oa0308 - 4%•• LIC EAS'e. , /SI` • Spedal Building Inspector Printed Name: Eduardo A.Roman Signature: f C5 ss /yy� CI Registered Architectand/or n Licensed Engineer j • !! o.* WIttIO� Special Inspector Signature: iO •• ,A ST4, Q Special Inspector Address: 7446 NW 11k 5[h Ter,Parkland 33076 % ``- ,c•( C \ OF Ssf��� c State of Florida Registration a: PE 71118 i/DF741 /Srgn� bate Phone:954-737-ea) Fax:_ Email:eduardo)ara-engineering.com "/i rrtiilllll\\• 'Plans for all buildings shall indicate how required structural and fire resistance integrity will be maintained where a penetration of a required fire resistant wall, floor or partition will be made for electrical,gas, mechanical,plumbing and communication conduits, pipes and systems. Such plans shall also indicate in sufficient detail how the fire integrity will be maintained where required fire resistant floors intersect the exterior walls and where joints occur in required fire resistant construction assemblies. S:\DevelopmenABUILDING\Threshold_Private Provider 2017 FormslSpecial Inspector_Private Provider.Application.docx ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING March 8, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N Permit#: 19-00002948 Reference: Building 3 SOG, foundation, and fill cells N Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in accordance of the approved drawings by the City of Boynton Beach. C No exceptions taken. C Best Regards, \ \�Qlllllrrrii N\` R 0 A. � ' , \ttttllllllrrr JP ...... p , \ \ Rp0 A 4p..• ��c N 9,G � Q\P,...... .. Rp • UCENS•' 2j 0. 7111 E EAVvy00. CC %.d STATE OP ((7 •, y ,err NAL \ /',,v�1:37.41. AL ENG\`. nittt Eduardo Roman PE., SI. PRESIDENT . PE 71118 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING March 24, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N 0 Permit#: 19-00002948 Reference: Building 3 Fill Cells 1St Floor Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in accordance of the approved drawings by the City of Boynton Beach. t No exceptions taken. d m Best Regards, 0011 IIj i1 i � JP�o N Rn 10, P¢•oENSE ^ ili • CO 0 pill Eitv". 71• i[���E — o . - W (l! 'O (Cl: o ��Q STATE OF (L\ TA i f'•� ` SO ` ‘ r' w i�� NAL,\ `4SIONAL� 11111110 Eduardo Roman PE., SI. PRESIDENT PE 71118 • • ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING March 24, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N N Permit#: 19-00002948 Reference: Building 3 HSS Column 151 Floor coU) N Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in accordance of the approved drawings by the City of Boynton Beach. 0) No exceptions taken. 03 0) Best Regards, co 0011111ifiti / \\ \11 � �A 111„ , /. CO ..�JQRD�,A: RO % \� P���... R0� N '• -9 \S • �\CENSE -•-./44, m Q Eikvimpla. 1 � , cc O STATE OF ; (U\ 11 s0T.:I:118/ /� '- F10R0 ` \ . /•SOS. \ Ce S . ♦ SIavnu. / SS!oNr- -F;;, / Eduardo Roman PE., SI. PRESIDENT PE 71118 • ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING March 27, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N N Permit#: 19-00002948 Reference: Building 3 2nd Floor Slab Steel Reinforcement tO Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in accordance of the approved drawings by the City of Boynton Beach. C No exceptions taken. C Best Regards, • 11II11111 \\`„� iii , � a �OJP �C .N R� 2 CSO..•' �,10ENSe * • No. i _ i. 711 IY . O0 STATE OF (V : '� w ,ill NAL ` .. S�uNAL ENS` Eduardo Roman PE., SI. PRESIDENT PE 71118 • ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 7, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL a Permit#: 19-00002948 co Reference: Building 3 Fill Cells 2nd Floor N Dear Building Official: e This is to certify that this office has observed the above reference reinforcement and it is in • accordance of the approved drawings by the City of Boynton Beach. No exceptions taken. C) Best Regards, \`0 II I I ,,,,; m EivviveVlo. 1 • -J./ • - • o ,�0�• STATE OF •' C(7�` �� / AT � � '2• Jai cS'•.F(OR1DP'.••• �� W ' S�ONAI E� '//,SIONPiL Eduardo Roman PE., SI. PRESIDENT PE 71118 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 7, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N N Permit#: 19-00002948 Reference: Building 3 HSS Column 2nd Floor ° Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in • accordance of the approved drawings by the City of Boynton Beach. No exceptions taken. m • Best Regards, PRD�.A•. RQ \r. �\GENSF '.y2. • -o O . A1C N `(V ' •t?[ m * : - ':c : 0.71 `��-�! Na. 1 / � a CO C e f/�lY CC o O •. STATEoF •�(U ' ' �I • STATE OF \ t ORM v' 1' • SiONAI EN OI AL \\ w ��Urrull�� � Eduardo Roman PE., SI. PRESIDENT PE 71118 • J ' ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 9, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N N Permit#: 19-00002948 Reference: Building 3 3rd Floor Slab Steel Reinforcement ° Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in accordance of the approved drawings by the City of Boynton Beach. No exceptions taken. Best Regards, • 0 BOJ• ��c N vq �ENSF PRo0.A. Jo % 00 R0" Eitvoila. * 7 ? 118* � cc =11: lU (Q o % ''. STATE OF CV a-sw ' I• STATEwCU llllo Eduardo Roman PE_ SI. PRESIDENT PE 71118 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 20, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7'h Avenue, Boynton Beach, FL N Permit#: 19-00002948 Reference: Building 3 Fill Cells 3rd Floor u) N Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in accordance of the approved drawings by the City of Boynton Beach. th No exceptions taken. a) a) Best Regards, CO �Q�• G N j9'G • O\ ...\GENSF 7i . * No. I — ://* rr z 0,71118 Ir : O STATE OF (V � STATE OF Lu; 4. co ul x,111111111'`\ /�', iIINA1\\\ Eduardo Roman PE., SI. PRESIDENT PE 71118 ARA ENGINEERING,INC. • ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 20, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N N Permit#: 19-00002948 Reference: Building 3 HSS Column 3rd Floor Dear Building Official: E This is to certify that this office has observed the above reference reinforcement and it is in accordance of the approved drawings by the City of Boynton Beach. No exceptions taken. Best Regards, n 1/ .‘‘ �R01A 1 R '', .‘ ``� 1111111j1 A. R a OJ44lGN '. O9 \�� AOQ........ 4 .. * 7 • S /118 ENSe c * E CO i11 twitiVO. . :• rte Cr / � o _ 0 % STATE OF �\ ,� , .s- OF =(LI` J.•' LU /j41111111� S/i //j/1111111�`` Eduardo Roman PE, SI. PRESIDENT PE 71118 ni ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING April 22, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N Permit#: 19-00002948 Reference: Building 3 Bond Beam •U) Dear Building Official: This is to certify that this office has observed the above reference reinforcement and it is in g accordance of the approved drawings by the City of Boynton Beach. No exceptions taken. a) C .5) C Best Regards, Lai 111Iiil ,1 P9' - a. 4QQ1:1 , " ,I I I I,,, ic ,v Zi92; �` VARDO q � . : R • c Eillivepo. * • _ ••//7111f1 o — � / * cc - • STATE OF �` O / W X11 1iONAL E� �� �c�q.. .••. /VIII IIID \\\ Roman PE., SI. PRESIDENT PE 71118 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING May 14, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N 01 Permit#: 19-00002948 Reference: Building 3 Roof Sheathing Dear Building Official: E This is to certify that this office has observed the roof sheathing and it is in accordance of the • approved drawings by the City of Boynton Beach. C No exceptions taken. • Best Regards, O 001111111/11. co0 ...-.. . Ott * .2 �$' • )CENSe &WA/ * E • �� • Q "�' • • STATE OF - • o �•. .-2.167/9 1111111100 - 8/C)NAL IIIA \\\ Eduardo Roman PE., SI. PRESIDENT PE 71118 • ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING May 20, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7Th Avenue, Boynton Beach, FL N Permit#: 19-00002948 Reference: Building 3 Window and door bucks Dear Building Official: £ This is to certify that this office has observed the installation of the window and door bucks and o it is in accordance of the approved drawings by the City of Boynton Beach. a, No exceptions taken. Best Regards, CD CO \``0ullllr,, .�` R00 A. f, m : JP x.10 N . �,�9ti z1 , I No. •. STATE OF C(7` .•`tORIO.:.. ..Ce\` /'",S"QNAL £\' w Eduardo Roman PE., SI. PRESIDENT PE 71118 ARA ENGINEERING,INC. • ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING May 2, 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 71h Avenue, Boynton Beach, FL N Q N Permit#: 19-00002948 Reference: Building 3 Roof Truss Erection Dear Building Official: E This is to certify that this office has observed the truss erection and it is in accordance of the • approved drawings by the City of Boynton Beach. • C No exceptions taken. a) m • Best Regards, 111111,,, CO ,.`` ki-cw.D R� 01110,1 p\ 17' c . .?iO a. ,; n � sN 1. J kCENSE- . _ � _ -• _ • - 8 '><t' o o • O -. STATE OF (0.z. E -. ORO -•• 'S N ��y J.- m i lrs ,1�"7' w �' ,1 ONAir E i619/ONAL 'iI„ 11n1111\\\\ Eduardo Roman PE., SI. PRESIDENT PE 71118 ARA ENGINEERING,INC. ENGINEERS-PLANNERS-CONSULTANTS SPECIAL INSPECTIONS-FORENSIC ENGINEERING Mayes? 2020 Building Official City of Boynton Beach Building Department 3301 Quantum Blvd Boynton Beach, FL 33426 Project: Ocean Breeze 100 NE 7th Avenue, Boynton Beach, FL N (0 (0 Permit #: 19-00002948 Reference: Building 3 Roof Engineering N Dear Building Official: E This is to certify that this office has observed the roof engineering and it is in accordance of the approved drawings by the City of Boynton Beach. m No exceptions taken. N 0) Best Regards, a `\\ 00 1A. 1/, ,III `JRRp �O•.• plc N 2iy ; ` n13 A. Rp,�''• ` * • No. i O\YP•• \GENS€ .'9 c * - _ 0.7111 co o , O STATE OF C(7\ TC ' i1„ '/ is G il••. / P NAL -\ -'oea `SAO E 0/� loRlo•.• �C\ (Li rrrinlll�` S, //1 /ONA� `= Eduardo Roman PE., SI. PRESIDENT PE 71118 AMERICAN TESTING MATERIALS ENGINEERING, LLC. a Testing_Laboratories-Englneenng Inspedlon Services-Chemist-Drilling Environmental Services riI/ 1 West 84th Street,Hialeah,Florida 33N4-Phone:30548 1888 Fex:305$48 1887 Field Density Test of Compacted Soils ASTM D4195 Client Ocean Breeze,LLC - - - Order 0: 20-0305 Address: 7735 NW 148th Street,Suite#308,Miami Lakes, FL 33018 Date: 3/52020 ..Project -- - - Ocean Breeze East Aparunents-Building 3 - -- Gauge SIN: 22745 4ddress: 703 N Seaaeat Blvd.,Boynton Beach,FL 33435 Phone No: Alex 305 2181490 Area: Slab on Grade Test Number Location(s) 1 NW corner of Bldg 2 25'E and 10'S from NW comer of Bldg 3 SW comer of Bldg 4 30'E from SW comer of Bldg 5 X80'E and 15'N from SW comer of Bldg l Description of Material: Brown sand with rocks - Fill I Backlit! I x I Subgrade I I Base Rock I Tested Br IYA Test Number 1 2 3 4 5 Depth(►s) 12" 12" 12" 12" 12" Field Density LB/Cu FL(Dry Density) 105.5 105.3 105.7 105.4 108.1 Moisture Contents 4.2 4.0 4.6 3.9 4.5 - Maximum Density in the Reid(%) 98.3 98.1 98.5 98.2 98.9 Compaction Requirement by Specs(%) 88.0 98.0 98.0 98.0 88.0 100%Matdmum Density(Lab)-AASNTO 1180 107.3 107.3 107.3 107.3 107.3 Optimum Moisture(%) 11.4 11.4 11.4 11.4 11.4 Status PASS PASS PASS PASS PASS I Remarks: Typed By: ak ``nntIIItttlrrffffff Res I ,,9 , f S. • rs .r ' , to. r .4ifd/i,J Waseca Quadri,P, ''51�,4LL81 i AMERICA) 1`ESTII� ( •`jtRIA1.4 ENGINEE1ji •L, LDRIDM •.•'$' 11",,, NAt Should any subsoil conditions In the property(area)pasted be found different from those enxtuntered on the tested locations reported on ow penally Test, Amerlcan Testing Malaria Engineering,LLC is not to be held responsible. Ase mutual protection to Went,the pudic and oumelves,ell reports are submitted as the iMamhl property of diems,and author ton for publication of shmnents,conclusions or extracts from our reports is reserved. AMERICAN TESTING MATERIALS ENGINEERING, LLC. Testing Laboratories-Engineering Inspection Services-Chemist-Drllling-Environmental Services 0 1950 West 84th Street,Hialeah, Florida 33014-Phone:305-646-1888 Fax:305 848 1667 Field Density Test of Compacted Soils ASTM D4196 Client Ocean Breeze,LLC Order 0: 20-0305 Address: 7735 NW 148th Street,Suite#306, Miami Lakes, FL 33016 Date: 3/5/2020 Project Ocean Breeze East Apartments•Building 3 Gauge SIN: 22745 Address: 703 N Seacrest Blvd., Boynton Beach, FL 33435 ' Phone No: Alex 305 2181480 Area: Slab on Grade Test Number r Location(s) 6 90'E and 25'N from SW corner of Bldg 7 70'E and 5'S from NW corner of Bldg 8 65'W from NE corner of Bldg 9 80'W from SE comer of Bldg 10 40'W from SE comer of Bldg l Description of Material: 'Brown sand with rocks Fill I Backfill I x I Subgrede ( I Base Rock I Tested By: PYA Test Number 6 7 8 9 10 Depth(in) 12" 12" 12" 12" 12" Field Density LB/Cu Ft.(Dry Density) 105.7 106.0 106.3 105.9 105.3 Moisture Contents 4.1 3.6 4.8 4.3 i 3.8 Maximum Density in the Field(%) 98,6 98.8 99,1 98.7 98.1 Compaction Requirement by Specs(%) 98.0 88.0 98.0 98.0 98.0 100%Maximum Density(Lab)•AASNTO T180 107.3 107.3 107.3 107.3 i 107.3 Optimum Moisture(%) 11.4 11.4 11.4 11.4 11.4 Status PASS PASS PASS PASS PASS Remarks: Typed By: ak +ea�"tc 0(J 0R��,� Respectfully tip �\c)tNSF• / , Of*4� :1k' . Waseem t�y8dri,P.E. j T¢8;1F lit AMERICANitSING t\ 3�� ENGINEERING •.l U}n ' C,, •`+ �'°9/ ''S'IONAA-<` Should any subsoil condltlona In the property(area)tested be found different from those encountered on the tested locations reported on our Density Test, American Testing Materials Englneedng,LLC is not to be held responsible. Asa mutual protection to client,the public and ourselves,all reports are submitted as the conndentlal property of clients,and authodmtion for publication of statements,conclusions or extracts from our reports Is reserved. AMERICAN TESTING MATERIALS ENGINEERING, LLC. Testing Laboratories-Engineering Inspection Senrices-Chemist-Drilling Environmental Services ire 1 West 84th Street,Hialeah,Florida 33014-Phone:305 848 1888 Fax:305 848 1887 Field Density Test of Compacted Soils ASTM 13.6195 Client Ocean Breeze,LLC Order#: 20-0305 Address: 7735 NW 148th Street,Suite#308,Miami Lakes,FL 33018 Date: 3/52020 Project Ocean Breeze East Apartments-Building 3 Gauge SIN: 22745 Address: 703 N Seacrest Blvd.,Boynton Beach,FL 33435 Phone No: Alex 305 2181490 Area: Slab on Grade Test Number I Location(s) 11 SE comer of Bldg 12 301N and 10'S from NE coiner of Bldg 13 NE corner of Bldg Description of Material: Brown sand with rocks . Fill I Back ill I x I Subgrade I I Base Rock Tested By: PYA Test Number 11 12 13 Depth(In) 12" 12" 12" Reid Density LB/Cu Ft(Dry Densly) 108.1 105.7 105.5 Moisture Contents 4.4 3.7 4.8 Maximum Density in the Reid(%) 98.9 98.5 98.3 Compaction Requirement by Specs(%) 98.0 98.0 98.0 100%Maximum Density(Lab)-AASHTO T180 107.3 107.3 107.3 Optimum Moisture(%) 11.4 11.4 1L4 l Status PASS PASS PASS Remarks: Typed By. ak `` talliiDpirpri!/t Respectfully s; ,` D ...AQR�%� S*..• ••\GENSE ' i'�• nla ��':is _ Waseem QfHt#i'•P.E.# 1 : :rx AMERICAN T.ES71NG IALS, ENGINEERING*., 'LOR\v..•', PP `SS(0NAA•'0\/ Should any subsoil condition In the property(area)tweed be found different from those enm mated on the tested brations reported on our Density Teat, American Testing Materials Engineering,LLC Is not to be held responsible. Asa mutual protection to client,the public and ourselves,as reports am submitted as the confidential property of titans,and authodragm for publication of statements,conclusions or enacts from our reports Is reserved. Qc'aside Envelope Leakage Test Report (Blower Door Test) RVICES Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2928 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 106 NE 7th Avenue Bldg: 3 Unit: 101 SQ/FT: 1105 City: Boynton Beach State: FL Zip: 33435 Alr Leakage Test Results Passing result must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI):r—1 s'o S x 60 + 9,834 = 3, 0 9 Method for calcul ating.buildingvoblmP• CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS ❑FAIL O Code software calculated fl When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined In Section 553.993(5)or(7),Florida Statues,or Individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the Intended weatherstripping or other infiltration control measures. 2.Dampers Including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interlor doors,if installed at the time of the test shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,If installed at the time of the test shall be turned off. 6.Supply and return registers,if Installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: --10• ..741-- Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority:BPI - Building Performance Institute :seaside Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2928 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: elk: Address: 106 NE 7th Avenue Bldg: 3 Unit: 102 SQ/FT: 1105 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form 8405-2017-Energy Calc(Performance)or R406-2017(FRO:F-1 SC 7 x 60 + 9,834 = 3, VS Method for calculatng.b uildinvolume CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans ZIPASS El FAIL O Code software calculated 0 When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth In Section 489.105(3)(f),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the Intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond Intended infiltration control measures. 3.Interlor doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,If Installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. 1/477, Signature of Tester: Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority:BPI - Building Performance Institute &aside Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2928 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 106 NE 7th Avenue Bldg: 3 Unit: 103 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ER!Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. / ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI):I-1 T/9� x 60 ÷ 8r152 = 3, 61 ? Method for calculating buiIdingvnhime CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans ZPASS ❑FAIL O Code software calculated When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other Infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interlor doors,if Installed at the time of the test,shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. S.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: �� Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute Vfieaside Envelope Leakage Test Report (Blower Door Test) ViCES Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach I Permit #: 19-2928 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 106 NE 7th Avenue Bldg: 3 Unit: 104 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(SO pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI): SOp 0Q / x 60 + 8,152 = / • .S 2 Methodfoccalculatinebuildingvolumrr CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans p;Ass ❑FAIL O Code software calculated ❑When ACI-050)is less than 3,Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted In accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interlor doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. • 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Gwr • Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute as \ asidEpv ,Ce Envelope Leakage Test Report (Blower Door Test)) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit if: 19-2928 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 106 NE 7th Avenue Bldg: 3 Unit: 105 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing result must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI): 476 / x 60 + 8,152 = ,3. 1rmMethndfa[>:alcu)ating,buildingvohIMP' CFM(50) Building Volume ACH(50) FIFAIL Retrieved from architectural plans ?ASS I FAIL O Code software calculated Q When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted In accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterlor windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers Including exhaust,Intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if Installed at the time of the test shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: ,..-F;;—&--7" Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute :seaside Envelope Leakage Test Report (Blower Door Test) E P J I C E Residential Prescriptive, Performance or ERI Method Compliance. 2017 Florida Building Code, EnergyConservation, 6th Edition Jurisdiction: Boynton Beach 1 Permit#: 19-2928 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 106 NE 7th Avenue Bldg: 3 Unit: 106 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ER!Method ©PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calc(Performance)por R406-2017(ERI): , SO ( x 60 + 8,152 = ,?. 68 Method for calculatinP hu ldingvolurP' CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS Fl FAIL O Code software calculated ❑When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined In Section 553393(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3Hf),(g).or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterlor windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures: 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,If installed at the time of the test,shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. S.Heating and cooling systems,If Installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: .--at. � ,Lr Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute aside Envelope Leakage Test Report (Blower Door Test) C./9 ER VIC r. S Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2928 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 106 NE 7th Avenue Bldg: 3 Unit: 107 SOFT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form P405-2017-Energy Ca/cc(Performance)or R406-2017(ERO: S-/ 3 x 60 _ 8r 152 = 3, 77 Method forsalnilatngbuildingvoluma CFM(50) Buildiin—g Volume ACH(50) Retrieved from architectural plans JIPASS I (FAIL O Code software calculated When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.21nche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)0),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code officio)Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond Intended infiltration control measures. 3.Interior doors,if installed at the time of the test shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and retum registers,if installed at the time of the test shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tesler: • fry4 Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute asoside Envelope Leakage Test Report (Blower Door Test) v I C E s Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach I Permit#: 19-2928 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 106 NE 7th Avenue Bldg: 3 Unit: 201 SQ/FT: 1105 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ER!: 1 .11 x 60 + 9[834 = 1,73 Method for rain udating huildirevoltimr• CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS [1 FAIL O Code software calculated C When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth In Section 489.105(3Nf),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing. 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and Rue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,If installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the complianceOmethod selected above. Signature of Tester: —4, T-3..�� Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute ;/easide Envelope Leakage Test Report (Blower Door Test) SERVICES Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach I Permit#: 19-2928 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 106 NE 7th Avenue Bldg: 3 Unit: 202 SQ/FT: 1105 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ER!Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. ()PERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form 8405-2017-Energy Calc(Performance)or R406-2017(ERI): 1 St' / x 60 + 9,834 = ,3, 30 Method for can daring huildingvoliime. CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PAS$ FAIL O Code software calculated When CH(50)is less than 3,Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. . Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined In section 551993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3Mf),(g).or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. . - 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. • Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: //li/• \ Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute :/Seaside Envelope Leakage Test Report (Blower Door Test) VICES Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2928 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 106 NE 7th Avenue Bldg: 3 Unit: 203 SOFT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI): SV 7 x 60 = 8,152 = 4/, 02 Method for catridatinahui)dingvolume. CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS FIFAIL O Code software calculated When ACH(50)is less than 3, Mechanical Ventilation , ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted In accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond Intended infiltration control measures. 3.Intedor doors,if Installed at the time of the test shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. S.Heating and cooling systems,If installed at the time of the test,shall be turned off. 6Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: // SFr _ , Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute a\aside Envelope Leakage Test Report (Blower Door Test) RVICES Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2928 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 106 NE 7th Avenue Bldg: 3 Unit: 204 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(SO pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Colt-(Performance)or R406-2017(ERI): 5- 62 x 60 + 8,152 = Si,7 /3 Method for calculating building volumP CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS inFAIL O Code software calculated ❑When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3Xf),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterlor windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the Intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond Intended infiltration control measures. 3.Interlor doors,if installed at the time of the test shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. S.Heating and cooling systems,If installed at the time of the test shall be turned off. 65upply and return registers,if installed at the time of the test shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: /i �� /� , Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute aaside Envelope Leakage Test Report (Blower Door Test) ICES Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach I Permit#: 19-2928 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 106 NE 7th Avenue Bldg: 3 Unit: 205 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ER!Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. `,Q ACH(50)specified on Form 12405.2017-Energy Calc(Performance)or R406.2017(ERI): 7 SS x 60 + 8,152 = 3, I( Mnthnd for ca)rtdating.buiidinv volume. CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans JPASS F1FAIL O code software calculated ❑When ACH(50)is less than 3, Mechanical Ventilation Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interlor doors,if installed at the time of the test,shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: • Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute Q "aside Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach I Permit#: 19-2928 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 106 NE 7th Avenue Bldg: 3 Unit: 206 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calc(Performance)rfJor R406-2017(ERI): z 7 x 60 + 8,152 = 3, 0 ` Method fcalculating.buildinavolume• CFM(50) Building Volume ACH(50) ��j�' ® Retrieved from architectural plans %ASS ['FAIL O Code software calculated ❑When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted In accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth In Section 489.105(3)(f),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interlor doors,if installed at the time of the test,shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if Installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: �/ • i /� . ' Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute �/easide Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2928 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 106 NE 7th Avenue Bldg: 3 Unit: 207 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. '/ACH(50)specified on Form R405.2017-Energy Calc(Performance)or R406-2017(ERI): 1 S/T x 60 + 8,152 = 3. 78 M,ethnd tasalculating buildingvolume CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS F1FAIL Q code software calculated ❑When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted In accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3Xf),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing. 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.lnterlor doors,if Installed at the time of the test shall be open. 4.Extedor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. S.Heating and cooling systems,if Installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester:_7_4:,7534r,„,___. Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority:BPI - Building Performance Institute ;/easide Envelope Leakage Test Report (Blower Door Test) SERvif_ ES Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2928 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 106 NE 7th Avenue Bldg: 3 Unit: 208 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Caiic(Performance)or R406-2017(ERI): OSx 60 + 8,152 = 4/, q7 Methnri.fgccalrtdatinebuildinvvoblmP CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS ❑FAIL O Code software calculated O When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined In Section 553.993(5)or(7),Ronda Statues,or individuals licensed as set forth in Section 489.105(3Xf),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust Intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interlor doors,if Installed at the time of the test,shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. S.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if Installed at the time of the test shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: \��_ Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute �ecogps Envelope Leakage Test Report (Blower Door Test) SE2 `/ICES Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach I Permit#: 19-2928 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 106 NE 7th Avenue Bldg: 3 Unit: 301 SQ/FT: 1105 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. /ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI): 1 6/6 x 60 + 10,276 = 3, S9 Method for Lalculatingbuildingvolume CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans KASS FIFAIL O Code software calculated When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth In Section 4S9.105(3Xf),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interlor doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test.shall be turned off. 6.5upply and return registers,if installed at the time of the test shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: '----,7-"(- 07;e:..--e- 1/4.757' Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification it: 5010864 Issuing Authority: BPI - Building Performance Institute :/easide Envelope Leakage Test Report (Blower Door Test) VICE Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach I Permit#: 19-2928 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 106 NE 7th Avenue Bldg: 3 Unit: 302 SQ/FT: 1105 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406.2017(ERO: a02 x 60 + 10,276 = 3.3 7 Methndfor caliculating.buildinvvohime' CFM(50)(� Building Volume ACI-1(50) ® Retrieved from architectural plans VkIPASS ❑FAIL O Code software calculated • ❑When ACH(50)is less than 3,Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted In accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers Including exhaust,Intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond Intended infiltration control measures. 3.Interlor doors,If installed at the time of the test.shall be open. 4.Exterlor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: � - fit Date of Test:_ 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute ;/easide Envelope Leakage Test Report (Blower Door Test) E k V !C E 5 Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2928 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: 81k: Address: 106 NE 7th Avenue Bldg: 3 Unit: 303 SCl/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ER!: ] 5-97 X 60 + 8,518 = 7./ ZO Method for 0Lnnlatingbyltdingvolume. CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans XPASs 17FAIL O Code software calculated ['When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted In accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers Including exhaust,Intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interlor doors,if Installed at the time of the test shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company . Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: C---e�4 i Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute :seaside Envelope Leakage Test Report (Blower Door Test) VICES Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach I Permit#: 19-2928 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 106 NE 7th Avenue Bldg: 3 Unit: 304 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ER!Method PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or(RI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. y ACH(50)specified on Form P405-20?7-Energy Calc(Performmance)or R406-2017(ERI): So x 60 + 8,518 = Q / Method fOLcaLrulatingbtiildingvnlumP. CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS FIFAIL O Code software calculated ❑when ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers Including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Intenor doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: - An _, - Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification It: 5010864 Issuing Authority: BPI - Building Performance Institute :seaside Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2928 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 106 NE 7th Avenue Bldg: 3 Unit: 305 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. / fo � rACH(S0)specified on Form 8405.2017-Energy Calc(Performance)or R406-2017(ERI): 57 x 60 + 8,518 = 3. 6 4 Method for calr'daringhuildinavolume. CFM(50) Building— Volume ACH(50) Retrieved from architectural plans IZPASS I (FAIL O Code software calculated ['When ACH(50)is less than 3,Mechanical Ventilation Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined In Section 553.993(5)or(7).Florida Statues,or individuals licensed as set forth In Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers Including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if Installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: UGl Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute Ei;/easide Envelope Leakage Test Report (Blower Door Test) SEk VICES Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2928 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 106 NE 7th Avenue Bldg: 3 Unit: 306 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI): 5-7G x 60 + 8,518 = 3. 70 Method fQLcaiculazingbuildingvobimP. CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans ,PASS Fl FAIL O Code software calculated U When ACI-1(50)is less than 3, Mechanical Ventilation , ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted In accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3X0,(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers Including exhaust Intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: astir_Ai Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute • :/easide Envelope Leakage Test Report (Blower Door Test) SERVICES Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach I Permit#: 19-2928 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 106 NE 7th Avenue Bldg: 3 Unit: 307 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406.2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(SO)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI):f .55 x 60 = 8,518 = 3, 9 Z Methodtacali'dating_buildinrvolume' CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PASS ❑FAIL O Code software calculated When ACH(50)is less than 3, Mechanical Ventilation Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 niche w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined In Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth In Section 489.105(3)(f),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interlor doors,if installed at the time of the test,shall be open. 4.Extedor doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: �� • �—E Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute :seaside Envelope Leakage Test Report (Blower Door Test) sERvic Es Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Boynton Beach Permit#: 19-2928 Job Information Builder: RS Construction Community: Ocean Breeze East Apartments Lot: Blk: Address: 106 NE 7th Avenue Bldg: 3 Unit: 308 SQ/FT: 916 City: Boynton Beach State: FL Zip: 33435 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ER!Method ®PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)In Climate Zones 1 and 2. OPERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on FORM R405.2017(Performance)or R406-2017(ERI),section labeled as Infiltration, sub-section ACH. ACH(50)specified on Form R405.2017-Energy CaaIcJ /(Perrffor-m7ance)or R406.2017(ERI): l / (O Z I x 60 + 8,518 = 5< Method for calrulatiflgbuildingvolume. CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans PS ASS F1FAIL O Code software calculated 0 When ACH(50)is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 Inche w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers Including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interlor doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. . 5.Heating and cooling systems,if installed at the time of the test shall be tumed off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company - Company Name: Seaside Services Org., LLC Phone: 954-778-7358 I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: —a en' Date of Test: 10/12/2020 Printed Name of Tester: Michael A. Lotesto License/Certification #: 5010864 Issuing Authority: BPI - Building Performance Institute