Loading...
ELEVATION CERTIFICATE OMB No: 1660-008 U.S. DEPARTMENT OF HOMELAND SECURITY Expiration Date: November 30, 2018 Federal Emergency Management Agency National Flood Insurance Program ELEVATION CERTIFICATE Important:Follow the instructions on Pages 1-9 Copy all Pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and(3) building owner. SECTION A – PROPERTY INFORMATION FOR INSURANCE COMPANY USE A1. Building Owner’s Name (Note: Not Valid to use for any other person or entity). Policy Number: K HOVNANIAN HOMES A2. Building Street Address (Including Apt., Unit, Suite, and/or Bldg. No. or P.O. Route and Company NAIC Number: Box No. 620 WINDWARD CIRCLE SOUTH, BUILDING 7 City State ZIP Code BOYNTON BEACHFL33435 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) LOT 37, CASA DEL MAR (PB 121 PG. 116 THROUGH 118 P.B.C.R.) A4. Building Use (e.g., Residential, Non-Residential, Addition, Accessory, etc.) MULTI-UNIT RESIDENTIAL A5. Latitude/Longitude: Lat. 26°33'10.19"N Long. 80° 03'15.12"W Horizontal Datum: NAD 1927 NAD 1983 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. A7. Building Diagram Number:1B A8. For a building with a crawlspace of enclosure(s): a)Square footage of crawlspace or enclosure(s) N/A sq. ft. b)Number of permanent flood openings in the crawlspace or enclosure(s) within 1.0 foot above adjacent grade 0 c)Total net area of flood openings in A8.b 0 sq. in. d)Engineered flood openings? Yes No A9. For a building with an attached garage: a)Square footage of attached garage 408 sq. ft. b)Number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade N/A c)Total net area of flood openings in A9.b N/A sq. in. d)Engineered flood openings? Yes No SECTION B – FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1. NFIP Community Name & Community NumberB2. County Name B3. State BOYNTON BEACH; 120196PALM BEACH COUNTY FLORIDA B4. Map/Panel B5. SuffixB6. Firm Index B7. FIRM PanelB8. Flood Zone(s) B9. Base Flood Elevation(s) Number Date Effective/ (Zone AO, use Base Revised Date Flood Depth) 12099C0 791 F 10/05/17 10/05/17 AE 6' B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9: FIS Profile FIRM Community Determined Other/Source: B11. Indicate Elevation Datum Used for BFE in Item B9: NGVD 1929 NAVD 1988 Other/Source: B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? Yes No Designation Date: N/A CBRS OPA FEMA Form 086-0-33 (7/15) Replaces all previous editions Page 1 of 6 OMB No: 1660-008 ELEVATION CERTIFICATE Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (Including Apt., Unit, Suite, and/or Bldg. No. or P.O. Route and Box No. Policy Number: 620 WINDWARD CIRCLE SOUTH, BUILDING 7 City State Zip Code Company NAIC Number: BOYNTON BEACHFL33435 SECTION C – BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) C1. Building Elevations are Based on: Construction Drawings* Building Under Construction* Finished Construction *A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations – Zones A1 - A30, AE, AH, A (with BFE), VE V1 – V30, V (with BFE), AR, AR/A, AR/AE, AR/A1 – A30, AR/AH, AR/AO. Complete Items C2.a – h below according to the building diagram specified in Item A7. In Puerto Rico only, enter meters. Benchmark Utilized: PALM BEACH COUNTY BENCHMARK #U233 EL=9.83' Vertical Datum:NAVD 1988 Indicate elevation datum used for the elevations in Items a) through h) below. NGVD 1929 NAVD 1988 Other/Source: Datum used for building elevations must be the same as that used for the BFE. Check the measurement used. a)Top of Bottom Floor (including basement, crawlspace, or enclosure floor) feet meters 7.58 b)Top of Next Higher Floor feet meters 18.91 c)Bottom of the lowest horizontal structural member (V Zones only) feet meters N.A d)Attached garage (top of slab) feet meters 6.88 e)Lowest elevation of machinery or equipment servicing the building feet meters 7.50 (Describe type of equipment and location in Comments) f)Lowest adjacent (finished) grade next to building (LAG) feet meters 6.90 g)Highest adjacent (finished) grade next to building (HAG) feet meters 7.10 h)Lowest adjacent grade at lowest elevation of deck or stairs, including N.A feet meters structural support SECTION D – SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. I certify that the information on this Certificate represents my best efforts to interpret the data available. I understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001. Were latitude and longitude in Section A provided by a licensed land surveyor? Yes No Check here if attachments. Certifier’s Name: License Number: Place David P. Lindley, PLSL.S. 5005 Seal Title: Here Professional Land Surveyor ___________________________ Company Name: David P. Lindley, PLS Caulfield & Wheeler, Inc. L.S. 5005, State of Florida Address: 08/09/2018 “Not Valid without the signature and 7900 Glades Road - Suite 100 the original raised seal of a Florida City:State:Zip Code: Licensed Surveyor & Mapper” Boca Raton FL33434 Signature: Date:Telephone: 08/09/2018 561-392-1991 Copy all Pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and(3) building owner. Comments (including type of equipment and location, per C2(e), if applicable. Item A5.) Latitude & Longitude obtained by Magellen GPS Blazer 12. Item C2.e) Refers to AC pads on east and west sides of the building. FEMA Form 086-0-33 (7/15)Replaces all previous editions Page 2 of 6 OMB No: 1660-008 ELEVATION CERTIFICATE Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (Including Apt., Unit, Suite, and/or Bldg. No. or P.O. Route and Box No. Policy Number: 620 WINDWARD CIRCLE SOUTH, BUILDING 7 City State Zip Code Company NAIC Number: BOYNTON BEACHFL33435 SECTION E –BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE A0 AND ZONE A (WITHOUT BFE) For Zones AO and A (Without BFE), complete Items E1-E5. If the Certificate is intended to support a LOMA and or LOMR-F request, complete Sections A, B, and C. For Items E1-E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters. E1. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, N/A. feet meters above or below the HAG crawlspace, or enclosure) is b) Top of bottom floor (including basement, N/A. feet meters above or below the LAG crawlspace, or enclosure) is E2. For Building Diagrams 6-9 with permanent flood openings provided in Section A Items 8 and/or 9 (see pages1-2 of instructions), the next higher floor (elevation C2.b in N/A. feet meters above or below the HAG the diagrams) of the building is E3. Attached Garage (top of slab) N/A. feet meters above or below the HAG E4. Top of platform of machinery and/or equipment N/A. feet meters above or below the HAG servicing the building is E5. Zone AO only: If no flood depth number is available, is the top of the floor elevated in accordance with the community’s floodplain management ordinance? Yes No Unknown. The local official must certify this information in Section G. SECTION F – PROPERTY OWNER (OR OWNER’S REPRESENTATIVE) CERTIFICATION The property owner or owner’s authorized representative who completes Sections A, B, and E for Zone A (without a FEMA-issued or community-issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Property Owner or Owner’s Authorized Representative’s Name: AddressCity State Zip Code Signature Date Telephone Comments Check here if attachments FEMA Form 086-0-33 (7/15) Replaces all previous editions Page 3 of 6 OMB No: 1660-008 ELEVATION CERTIFICATE Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (Including Apt., Unit, Suite, and/or Bldg. No. or P.O. Route and Box No. Policy Number: 620 WINDWARD CIRCLE SOUTH, BUILDING 7 City State Zip Code Company NAIC Number: BOYNTON BEACHFL33435 SECTION G–COMMUNITY INFORMATION (OPTIONAL) The local official who is authorized by law or ordinance to administer the community’s floodplain management ordinance can complete Sections A, B, C (or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G8 – G10. In Puerto Rico only, enter meters. G1. The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below). G2. A community official completed Section E for a building located in Zone A (without a FEMA-issued or community issued BFE) or Zone AO. G3. The following information (Items G4 – G10) is provided for community floodplain management purposes. G4. Permit Number G5. Date Permit IssuedG6. Date Certificate of Compliance/Occupancy Issued G7. This Permit has been issued for: New Construction Substantial Improvement G8. Elevation of as-built lowest floor (including basement) . feet meters Datum of the building: G9. BFE or (Zone AO) depth of flooding at the building site: . feet meters Datum G10. Community’s design flood elevation: . feet meters Datum The property owner or owner’s authorized representative who completes Sections A, B, and E for Zone A (without a FEMA-issued or community-issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Local Official’s Name Title Community NameTelephone Signature Date Comments Check here if attachments FEMA Form 086-0-33 (7/15) Replaces all previous editions Page 4 of 6 BUILDING PHOTOGRAPHS OMB No: 1660-008 See Instructions for Item A6 ELEVATION CERTIFICATE Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (Including Apt., Unit, Suite, and/or Bldg. No. or P.O. Route and Box No. Policy Number: 620 WINDWARD CIRCLE SOUTH, BUILDING 7 CityStateZip Code Company NAIC Number: BOYNTON BEACHFL33435 If using the Elevation Certificate to obtain NFIP flood insurance, affix at least 2 building photographs below according to the instructions for Item A6. Identify all photographs with date taken; “Front view” and “Rear view”; and, if required, “Right Side View” and “Left Side View.” When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. If submitting more photographs than will fit on this page, use the Continuation Page. Photo One Caption: Front View Photo Three Caption: Rear View Photo Two Caption: Photo Four Caption: FEMA Form 086-0-33 (7/15)Replaces all previous editions Page 5 of 6 BUILDING PHOTOGRAPHS OMB No: 1660-008 See Instructions for Item A6 ELEVATION CERTIFICATE Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (Including Apt., Unit, Suite, and/or Bldg. No. or P.O. Route and Box No. Policy Number: 620 WINDWARD CIRCLE SOUTH, BUILDING 7 City StateZip Code Company NAIC Number: BOYNTON BEACHFL33435 If Submitting more photographs that will fit on the preceding page, affix the additional photographs below. Identify all photographs with: date taken; “Front view” and “Rear view”; and, if required, “Right Side View” and “Left Side View.” When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. Photo One Caption: Left Side View Photo Three Caption: Right Side View Photo Two Caption: Photo Four Caption: FEMA Form 086-0-33 (7/15)Replaces all previous editions Page 6 of 6 PROPERTY DESCRIPTION ATTACHMENT (Optional – Use this page only if the property description is too lengthy.) ELEVATION CERTIFICATE