Loading...
PERMIT DOCUMENTS Certificate of Authorization No. 29824 17520 Edinburgh Dr a CREEK Tampa, FL 33647 (813) 480-3421 Technical Services, LLC TH EVALUATION REPORT F LORIDA B UILDING C ODE 6 E DITION (2017) Manufacturer: BORAL ROOFING LLC Issued February 19, 2019 7575 Irvine Center Drive Irvine, CA 92618 (800) 669-8453 www.boralamerica.com Manufacturing Plants: Lake Wales, FL Okeechobee, FL Quality Assurance: PRI Construction Materials Technologies (QUA9110) S COPE Category: Roofing Subcategory: Roofing Tiles Code Sections: 1507.3.5, 1507.3.7, 1523.6.5, 1523.6.5.2, 1523.6.5.2.2, 1523.6.5.2.3 Properties: Physical Properties, Attachment Requirements, Wind Driven Rain, Static Uplift Resistance R EFERENCES Entity Report No. Standard Year American Test Lab of South Florida Inc (TST3782) RT0201.01-19 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc (TST3782) RT0130.01-14 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc (TST3782) RT0426.01-14 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc (TST3782) RT0615.02-11 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc (TST3782) RT0615.03-11 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc (TST3782) RT0615.04-11 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc (TST3782) RT0617.02-16 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc (TST3782) RT0617.03-16 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc (TST3782) RT0617.04-16 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc (TST3782) RT0623.04-14 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc (TST3782) RT0624.04-14 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc (TST3782) RT0624.05-14 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc (TST3782) RT1210.02-15 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc (TST3782) RT1210.03-15 TAS 112 1995 ASTM C 1492 2003(2009) Miami-Dade BCCO (CER1592) 14-0408.06 FBC (HVHZ) 2017 Miami-Dade BCCO (CER1592) 14-0416.12 FBC (HVHZ) 2017 Miami-Dade BCCO (CER1592) 15-0721.04 FBC (HVHZ) 2017 Miami-Dade BCCO (CER1592) 16-0112.07 FBC (HVHZ) 2017 Miami-Dade BCCO (CER1592) 16-0112.08 FBC (HVHZ) 2017 Miami-Dade BCCO (CER1592) 18-0509.15 FBC (HVHZ) 2017 Miami-Dade BCCO (CER1592) 18-0509.16 FBC (HVHZ) 2017 Miami-Dade BCCO (CER1592) 18-0509.17 FBC (HVHZ) 2017 BOR18003.1 FL28328-R1 Page 1 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. BORAL ROOFING LLC A CREEK Concrete Roof Tiles Technical Services, LLC Entity Report No. Standard Year Tile Roof Institute Membership Confirmation TAS 100 1995 TAS 101 1995 TAS 102 & 102(A) 1995 BOR18003.1 FL28328-R1 Page 2 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. BORAL ROOFING LLC A CREEK Concrete Roof Tiles Technical Services, LLC P RODUCT D ESCRIPTION Bermuda (Okeechobee) Profile/Description: ASTM C 1492, TAS 112 Type 3a, flat profile, interlocking, class III concrete roof tile Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications Dimensions: Figure 1. Bermuda Plantation (Okeechobee) Profile/Description: ASTM C 1492, TAS 112 Type 3a, flat profile, interlocking, class III concrete roof tile Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications Dimensions: 16- Figure 2. Plantation BOR18003.1 FL28328-R1 Page 3 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. BORAL ROOFING LLC A CREEK Concrete Roof Tiles Technical Services, LLC Saxony 900 Slate, Shake and Split Shake (Lake Wales and Okeechobee) Profile/Description: ASTM C 1492, TAS 112 Type 3a, flat profile, interlocking, class III concrete roof tile Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications Dimensions: 17131-5/32 (Slate) or 1-9/plit Shake) Figure 3. Saxony 900 Slate Figure 4. Saxony 900 Shake Figure 5. Saxony 900 Split Shake BOR18003.1 FL28328-R1 Page 4 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. BORAL ROOFING LLC A CREEK Concrete Roof Tiles Technical Services, LLC Estate (Okeechobee) Profile/Description: ASTM C 1492, TAS 112 Type 1b, low profile, interlocking, class III concrete roof tile Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications Dimensions: 16- Figure 6. Estate Villa 900 (Lake Wales) Profile/Description: ASTM C 1492, TAS 112 Type 1b, low profile, interlocking, class III concrete roof tile Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications Dimensions: - Figure 7. Villa 900 BOR18003.1 FL28328-R1 Page 5 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. BORAL ROOFING LLC A CREEK Concrete Roof Tiles Technical Services, LLC Barcelona 900 (Lake Wales) Profile/Description: ASTM C 1492, TAS 112 Type 1a, high profile, interlocking, class III, concrete roof tile Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications Dimensions: 173-5/8 Figure 8. Barcelona 900 Galena (Okeechobee) Profile/Description: ASTM C 1492, TAS 112 Type 2a, high profile, concrete roof tile Allowable Applications: For mechanically fastened (direct deck), mortar set or adhesive set applications Dimensions: 17102.7 Figure 9 BOR18003.1 FL28328-R1 Page 6 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. BORAL ROOFING LLC A CREEK Concrete Roof Tiles Technical Services, LLC (Lake Wales) Profile/Description: ASTM C 1492, TAS 112 Type 2a, high profile, interlocking, class III concrete roof tile Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications Dimensions: 179-3/42-27/32 Figure 10 A PPLICATION M ETHOD Installation Limited to slopes 3:12 or greater in the HVHZ; Outside the HVHZ, shall be in accordance with the recommendations of the FRSA/TRI Florida High Wind Concrete and Clay Roof Slope: Tile Installation Manual, Fifth Edition Revised or RAS 118, RAS 119, or RAS 120, as applicable. Solid or closely fitted min. 15/32-inch plywood sheathing for new and existing construction Roof Deck: at max. 24 in. span; In the HVHZ, new construction shall be min. 19/32 in. plywood at max. 24 in. span; Designed by others in accordance with FBC requirements. Installed in accordance with FBC requirements. In the HVHZ, the minimum underlayment Underlayment: shall be installed as described in RAS 118, RAS 119, or RAS 120, as applicable. BOR18003.1 FL28328-R1 Page 7 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. BORAL ROOFING LLC A CREEK Concrete Roof Tiles Technical Services, LLC Data for Attachment Calculations for Direct to Deck Applications Aerodynamic Nominal Weight (W) and Restoring Moments due to Gravity - M (ft-lbf) g Multipliers Dimensions (l x w) Direct Deck 3 (ft) Roof Tile Direct Deck W (lbf) l (ft) w (ft) > Application Bermuda 9.7 1.33 0.833 0.205 6.97 6.86 6.71 6.54 6.35 Plantation 11.6 1.375 1.08 0.289 7.79 7.67 7.52 7.32 7.04 Saxony 900 10.9 1.417 1.08 0.315 7.62 7.5 7.34 7.16 6.95 Estate 10.0 1.375 1.08 0.289 6.74 6.64 6.50 6.33 6.14 Villa 900 10.9 1.42 1.08 0.315 7.62 7.50 7.34 7.15 6.95 Barcelona 11.5 1.417 1.08 0.301 7.00 6.90 6.76 6.60 6.42 900 Galena 8.5 1.42 0.833 0.235 6.13 6.03 5.89 5.74 5.57 8.95 1.417 0.8125 0.233 5.93 5.83 5.70 5.56 5.39 Nuevo Data for Attachment Calculations for Batten Applications Aerodynamic Nominal Weight (W) and Restoring Moments due to Gravity - M (ft-lbf) g Multipliers Dimensions (l x w) Direct Deck 3 ) Roof Tile Batten W (lbf) l (ft) w (ft) > Application Bermuda 9.7 1.33 0.833 0.189 6.53 6.43 6.29 6.14 5.97 Plantation 11.6 1.375 1.08 0.267 6.85 6.75 6.61 6.44 6.26 Saxony 900 10.9 1.417 1.08 0.291 - 6.61 6.48 6.31 6.13 Estate 10.0 1.375 1.08 0.267 5.91 5.82 5.70 5.56 5.40 Villa 900 10.9 1.42 1.08 0.291 - 6.56 6.42 6.26 6.08 Barcelona 11.5 1.417 1.08 0.286 6.19 6.19 6.06 5.92 5.76 900 8.95 1.417 0.8125 0.215 5.30 5.21 5.09 4.96 4.82 Nuevo BOR18003.1 FL28328-R1 Page 8 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. BORAL ROOFING LLC A CREEK Concrete Roof Tiles Technical Services, LLC Attachment Resistance Expressed as a Moment for Mechanically Fastened Applications Tile Fastener M (ft-lbf) f Roof Tile Direct Deck Direct Deck Type Count Size Shank ClipBattens plywood)plywood) Nail 2 10d Ring N/A 30.9 38.1 17.2 Smooth Nail 1 10d N/A 7.3 9.8 4.9 or Screw Smooth Nail 2 10d N/A 14.0 18.8 7.4 or Screw Screw 1 #8 N/A N/A 30.8 30.8 18.2 Screw 2 #8 N/A N/A 51.7 51.7 24.4 Bermuda, Plantation or Smooth Saxony 900 Nail 1 10d Field 24.3 24.3 24.2 or Screw Smooth Nail 1 10d Eave 19.0 19.0 22.1 or Screw Smooth Nail 2 10d Field 35.5 35.5 34.8 or Screw Smooth Nail 2 10d Eave 31.9 31.9 32.2 or Screw 1 Nail2 10d Ring N/A 50.3 65.5 48.3 Nail 2 10d Ring N/A 27.8 37.4 28.8 Smooth Nail1 10d N/A 8.8 11.8 4.1 or Screw Smooth Nail 2 10d N/A 16.4 21.9 7.1 or Screw Screw1 #8 N/A N/A 25.8 25.8 22.9 2 , Screw 2 #8 N/A N/A 47.1 47.1 49.1 Villa 900 Smooth Nail 1 10d Field 24.3 24.3 24.2 or Screw Smooth Nail 1 10d Eave 19.0 19.0 22.1 or Screw Smooth Nail 2 10d Field 35.5 35.5 34.8 or Screw Smooth Nail 2 10d Eave 31.9 31.9 32.2 or Screw 1 Nail2 10d Ring N/A 43.0 67.5 50.9 Continued on following page BOR18003.1 FL28328-R1 Page 9 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. BORAL ROOFING LLC A CREEK Concrete Roof Tiles Technical Services, LLC Attachment Resistance Expressed as a Moment for Mechanically Fastened Applications Tile Fastener M (ft-lbf) f Roof Tile Direct Deck Direct Deck Type Count Size Shank ClipBattens plywood)plywood) Nail 2 10d Ring N/A 28.6 41.2 19.4 Smooth Nail 1 10d N/A 5.1 6.8 2.8 or Screw Smooth Nail 2 10d N/A 6.9 9.2 7.3 or Screw Screw 1 #8 N/A N/A 20.7 20.7 18.1 Barcelona 900, Screw 2 #8 N/A N/A 43.2 43.2 29.8 3 Galena or Smooth Nail 1 10d Field 23.1 23.1 19.0 Nuevo or Screw Smooth Nail 1 10d Eave 29.3 29.3 24.0 or Screw Smooth Nail 2 10d Field 27.6 27.6 38.6 or Screw Smooth Nail 2 10d Eave 38.1 38.1 41.8 or Screw 1 Nail2 10d Ring N/A 33.1 48.1 45.2 Notes: 1) Not for Saxony 900, Villa 900 or Barcelona 900. located a min. 2- from head of tile. 2) When using only one fastener, use the hole that is approximately 4- interlocking edge. 3) Direct Deck applications only. Attachment Resistance Expressed as a Moment for Adhesive or Mortar Set Paddy Average Paddy 1 Roof Tile AdhesiveProduct ApprovalM (ft-lbf) f CountWeight (grams) Dow NOA 16-0222.01 2 13.9 31.3 Bermuda, 2 8 31.3 Planation and ICP Adhesives Polyset AH-160 NOA 17-0322.03 1 24 40.4 Saxony 900 1 45 118.9 2 8 59.0 NOA 17-0829.12 1 24 45 -Component Saxony 900 1 45 93 Premix Marbletite, Inc. TILE-TITE NOA 17-1016.07 N/A N/A 43.9 NOA 16-0222.01 2 11.4 26.1 2 8 26.1 ICP Adhesives Polyset AH-160 NOA 17-0322.03 1 24 45.5 Villa 900 1 54 86.61 Premix Marbletite, Inc. TILE-TITE NOA 17-1016.07 N/A N/A 20.6 2 8 55 Villa 900 NOA 17-0829.12 1 30 40 -Component 1 60 70 BOR18003.1 FL28328-R1 Page 10 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. BORAL ROOFING LLC A CREEK Concrete Roof Tiles Technical Services, LLC Attachment Resistance Expressed as a Moment for Adhesive or Mortar Set Paddy Average Paddy 1 Roof Tile AdhesiveProduct ApprovalM (ft-lbf) f CountWeight (grams) NOA 16-0222.01 2 10.7 29.3 Barcelona 900, 2 8 29.3 Galena Spanish ICP Adhesives Polyset AH-160 NOA 17-0322.03 1 24 38.7 1 63 66.5 Premix Marbletite, Inc. TILE-TITE NOA 17-1016.07 N/A N/A 24.5 2 8 66.0 Barcelona 900 NOA 17-0829.12 1 30 63 -Component 1 60 82 Notes: 1) L ABELING 1) ağƓǒŅğĭƷǒƩĻķ źƓ \[ğƉĻ ‘ğƌĻƭͲ C\[ ağƓǒŅğĭƷǒƩĻķ źƓ hƉĻĻĭŷƚĬĻĻͲ C\[ OR BOR18003.1 FL28328-R1 Page 11 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. BORAL ROOFING LLC A CREEK Concrete Roof Tiles Technical Services, LLC L IMITATIONS 1)Fire Classification is not within the scope of this evaluation. 2)Installation of the evaluated products shall comply with FBC Section 1507.3, FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Fifth Edition Revised application instructions. Installations in the HVHZ shall comply with RAS 118, RAS119 and RAS 120. 3)All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. 4)All product listed in this shall tested quarterly in accordance with TAS 112 Appendix A. 5)Installation of the evaluated products shall be limited to projects in areas subjected to weathering indices of 50or greater as illustrated in ASTM C 1492-03, figure 1 (see below). C OMPLIANCE S TATEMENT The products evaluated herein by Zachary R Priest P.E. have demonstrated compliance with the Florida Building th Code, 6 Edition (2017)as evidenced in the referenced documents submitted by the named manufacturer. 312:/13/2 :!21;21;33! .16(11( Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 C ERTIFICATION OF I NDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does nothave, nor will acquire, a financial interest in any other entity involved in the approval process of the product. E ND OF R EPORT BOR18003.1FL28328-R1Page 12 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.