EVALUATION REPORT F LORIDA B UILDING C ODE 6 E DITION (2017)
Manufacturer:
BORAL ROOFING LLC Issued February 19, 2019
7575 Irvine Center Drive
Irvine, CA 92618
(800) 669-8453
www.boralamerica.com
Manufacturing Plants:
Lake Wales, FL
Okeechobee, FL
Quality Assurance:
PRI Construction Materials Technologies (QUA9110)
S COPE
Category:
Roofing
Subcategory:
Roofing Tiles
Code Sections:
1507.3.5, 1507.3.7, 1523.6.5, 1523.6.5.2, 1523.6.5.2.2, 1523.6.5.2.3
Properties:
Physical Properties, Attachment Requirements, Wind Driven Rain, Static Uplift
Resistance
R EFERENCES
Entity Report No. Standard Year
American Test Lab of South Florida Inc (TST3782) RT0201.01-19 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc (TST3782) RT0130.01-14 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc (TST3782) RT0426.01-14 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc (TST3782) RT0615.02-11 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc (TST3782) RT0615.03-11 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc (TST3782) RT0615.04-11 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc (TST3782) RT0617.02-16 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc (TST3782) RT0617.03-16 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc (TST3782) RT0617.04-16 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc (TST3782) RT0623.04-14 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc (TST3782) RT0624.04-14 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc (TST3782) RT0624.05-14 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc (TST3782) RT1210.02-15 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc (TST3782) RT1210.03-15 TAS 112 1995
ASTM C 1492 2003(2009)
Miami-Dade BCCO (CER1592) 14-0408.06 FBC (HVHZ) 2017
Miami-Dade BCCO (CER1592) 14-0416.12 FBC (HVHZ) 2017
Miami-Dade BCCO (CER1592) 15-0721.04 FBC (HVHZ) 2017
Miami-Dade BCCO (CER1592) 16-0112.07 FBC (HVHZ) 2017
Miami-Dade BCCO (CER1592) 16-0112.08 FBC (HVHZ) 2017
Miami-Dade BCCO (CER1592) 18-0509.15 FBC (HVHZ) 2017
Miami-Dade BCCO (CER1592) 18-0509.16 FBC (HVHZ) 2017
Miami-Dade BCCO (CER1592) 18-0509.17 FBC (HVHZ) 2017
BOR18003.1 FL28328-R1 Page 1 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
BORAL ROOFING LLC
A CREEK Concrete Roof Tiles
Technical Services, LLC
Entity Report No. Standard Year
Tile Roof Institute Membership Confirmation TAS 100 1995
TAS 101 1995
TAS 102 & 102(A) 1995
BOR18003.1 FL28328-R1 Page 2 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
BORAL ROOFING LLC
A CREEK Concrete Roof Tiles
Technical Services, LLC
P RODUCT D ESCRIPTION
Bermuda (Okeechobee)
Profile/Description:
ASTM C 1492, TAS 112 Type 3a, flat profile, interlocking, class III concrete roof tile
Allowable Applications:
For mechanically fastened (direct deck or batten), mortar set or adhesive set applications
Dimensions:
Figure 1. Bermuda
Plantation (Okeechobee)
Profile/Description:
ASTM C 1492, TAS 112 Type 3a, flat profile, interlocking, class III concrete roof tile
Allowable Applications:
For mechanically fastened (direct deck or batten), mortar set or adhesive set applications
Dimensions:
16-
Figure 2. Plantation
BOR18003.1 FL28328-R1 Page 3 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
BORAL ROOFING LLC
A CREEK Concrete Roof Tiles
Technical Services, LLC
Saxony 900 Slate, Shake and Split Shake (Lake Wales and Okeechobee)
Profile/Description:
ASTM C 1492, TAS 112 Type 3a, flat profile, interlocking, class III concrete roof tile
Allowable Applications:
For mechanically fastened (direct deck or batten), mortar set or adhesive set applications
Dimensions:
17131-5/32 (Slate) or 1-9/plit Shake)
Figure 3. Saxony 900 Slate
Figure 4. Saxony 900 Shake
Figure 5. Saxony 900 Split Shake
BOR18003.1 FL28328-R1 Page 4 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
BORAL ROOFING LLC
A CREEK Concrete Roof Tiles
Technical Services, LLC
Estate (Okeechobee)
Profile/Description:
ASTM C 1492, TAS 112 Type 1b, low profile, interlocking, class III concrete roof tile
Allowable Applications:
For mechanically fastened (direct deck or batten), mortar set or adhesive set applications
Dimensions:
16-
Figure 6. Estate
Villa 900 (Lake Wales)
Profile/Description:
ASTM C 1492, TAS 112 Type 1b, low profile, interlocking, class III concrete roof tile
Allowable Applications:
For mechanically fastened (direct deck or batten), mortar set or adhesive set applications
Dimensions:
-
Figure 7. Villa 900
BOR18003.1 FL28328-R1 Page 5 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
BORAL ROOFING LLC
A CREEK Concrete Roof Tiles
Technical Services, LLC
Barcelona 900 (Lake Wales)
Profile/Description:
ASTM C 1492, TAS 112 Type 1a, high profile, interlocking, class III, concrete
roof tile
Allowable Applications:
For mechanically fastened (direct deck or batten), mortar set or adhesive set applications
Dimensions:
173-5/8
Figure 8. Barcelona 900
Galena (Okeechobee)
Profile/Description:
ASTM C 1492, TAS 112 Type 2a, high profile, concrete
roof tile
Allowable Applications:
For mechanically fastened (direct deck), mortar set or adhesive set applications
Dimensions:
17102.7
Figure 9
BOR18003.1 FL28328-R1 Page 6 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
BORAL ROOFING LLC
A CREEK Concrete Roof Tiles
Technical Services, LLC
(Lake Wales)
Profile/Description:
ASTM C 1492, TAS 112 Type 2a, high profile, interlocking, class III concrete
roof tile
Allowable Applications:
For mechanically fastened (direct deck or batten), mortar set or adhesive set applications
Dimensions:
179-3/42-27/32
Figure 10
A PPLICATION M ETHOD
Installation
Limited to slopes 3:12 or greater in the HVHZ; Outside the HVHZ, shall be in accordance
with the recommendations of the FRSA/TRI Florida High Wind Concrete and Clay Roof
Slope:
Tile Installation Manual, Fifth Edition Revised or RAS 118, RAS 119, or RAS 120, as
applicable.
Solid or closely fitted min. 15/32-inch plywood sheathing for new and existing construction
Roof Deck: at max. 24 in. span; In the HVHZ, new construction shall be min. 19/32 in. plywood at max.
24 in. span; Designed by others in accordance with FBC requirements.
Installed in accordance with FBC requirements. In the HVHZ, the minimum underlayment
Underlayment:
shall be installed as described in RAS 118, RAS 119, or RAS 120, as applicable.
BOR18003.1 FL28328-R1 Page 7 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
BORAL ROOFING LLC
A CREEK Concrete Roof Tiles
Technical Services, LLC
Data for Attachment Calculations for Direct to Deck Applications
Aerodynamic
Nominal Weight (W) and Restoring Moments due to Gravity - M (ft-lbf)
g
Multipliers
Dimensions (l x w) Direct Deck
3
(ft)
Roof Tile
Direct Deck
W (lbf) l (ft) w (ft) >
Application
Bermuda 9.7 1.33 0.833 0.205 6.97 6.86 6.71 6.54 6.35
Plantation 11.6 1.375 1.08 0.289 7.79 7.67 7.52 7.32 7.04
Saxony 900 10.9 1.417 1.08 0.315 7.62 7.5 7.34 7.16 6.95
Estate 10.0 1.375 1.08 0.289 6.74 6.64 6.50 6.33 6.14
Villa 900 10.9 1.42 1.08 0.315 7.62 7.50 7.34 7.15 6.95
Barcelona
11.5 1.417 1.08 0.301 7.00 6.90 6.76 6.60 6.42
900
Galena
8.5 1.42 0.833 0.235 6.13 6.03 5.89 5.74 5.57
8.95 1.417 0.8125 0.233 5.93 5.83 5.70 5.56 5.39
Nuevo
Data for Attachment Calculations for Batten Applications
Aerodynamic
Nominal Weight (W) and Restoring Moments due to Gravity - M (ft-lbf)
g
Multipliers
Dimensions (l x w) Direct Deck
3
)
Roof Tile
Batten
W (lbf) l (ft) w (ft) >
Application
Bermuda 9.7 1.33 0.833 0.189 6.53 6.43 6.29 6.14 5.97
Plantation 11.6 1.375 1.08 0.267 6.85 6.75 6.61 6.44 6.26
Saxony 900 10.9 1.417 1.08 0.291 - 6.61 6.48 6.31 6.13
Estate 10.0 1.375 1.08 0.267 5.91 5.82 5.70 5.56 5.40
Villa 900 10.9 1.42 1.08 0.291 - 6.56 6.42 6.26 6.08
Barcelona
11.5 1.417 1.08 0.286 6.19 6.19 6.06 5.92 5.76
900
8.95 1.417 0.8125 0.215 5.30 5.21 5.09 4.96 4.82
Nuevo
BOR18003.1 FL28328-R1 Page 8 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
BORAL ROOFING LLC
A CREEK Concrete Roof Tiles
Technical Services, LLC
Attachment Resistance Expressed as a Moment for Mechanically Fastened Applications
Tile Fastener M (ft-lbf)
f
Roof Tile
Direct Deck Direct Deck
Type Count Size Shank ClipBattens
plywood)plywood)
Nail 2 10d Ring N/A 30.9 38.1 17.2
Smooth
Nail 1 10d N/A 7.3 9.8 4.9
or Screw
Smooth
Nail 2 10d N/A 14.0 18.8 7.4
or Screw
Screw 1 #8 N/A N/A 30.8 30.8 18.2
Screw 2 #8 N/A N/A 51.7 51.7 24.4
Bermuda,
Plantation or
Smooth
Saxony 900
Nail 1 10d Field 24.3 24.3 24.2
or Screw
Smooth
Nail 1 10d Eave 19.0 19.0 22.1
or Screw
Smooth
Nail 2 10d Field 35.5 35.5 34.8
or Screw
Smooth
Nail 2 10d Eave 31.9 31.9 32.2
or Screw
1
Nail2 10d Ring N/A 50.3 65.5 48.3
Nail 2 10d Ring N/A 27.8 37.4 28.8
Smooth
Nail1 10d N/A 8.8 11.8 4.1
or Screw
Smooth
Nail 2 10d N/A 16.4 21.9 7.1
or Screw
Screw1 #8 N/A N/A 25.8 25.8 22.9
2
,
Screw 2 #8 N/A N/A 47.1 47.1 49.1
Villa 900
Smooth
Nail 1 10d Field 24.3 24.3 24.2
or Screw
Smooth
Nail 1 10d Eave 19.0 19.0 22.1
or Screw
Smooth
Nail 2 10d Field 35.5 35.5 34.8
or Screw
Smooth
Nail 2 10d Eave 31.9 31.9 32.2
or Screw
1
Nail2 10d Ring N/A 43.0 67.5 50.9
Continued on following page
BOR18003.1 FL28328-R1 Page 9 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
BORAL ROOFING LLC
A CREEK Concrete Roof Tiles
Technical Services, LLC
Attachment Resistance Expressed as a Moment for Mechanically Fastened Applications
Tile Fastener M (ft-lbf)
f
Roof Tile
Direct Deck Direct Deck
Type Count Size Shank ClipBattens
plywood)plywood)
Nail 2 10d Ring N/A 28.6 41.2 19.4
Smooth
Nail 1 10d N/A 5.1 6.8 2.8
or Screw
Smooth
Nail 2 10d N/A 6.9 9.2 7.3
or Screw
Screw 1 #8 N/A N/A 20.7 20.7 18.1
Barcelona 900,
Screw 2 #8 N/A N/A 43.2 43.2 29.8
3
Galena or
Smooth
Nail 1 10d Field 23.1 23.1 19.0
Nuevo
or Screw
Smooth
Nail 1 10d Eave 29.3 29.3 24.0
or Screw
Smooth
Nail 2 10d Field 27.6 27.6 38.6
or Screw
Smooth
Nail 2 10d Eave 38.1 38.1 41.8
or Screw
1
Nail2 10d Ring N/A 33.1 48.1 45.2
Notes: 1) Not for Saxony 900, Villa 900 or Barcelona 900. located a min. 2-
from head of tile.
2) When using only one fastener, use the hole that is approximately 4- interlocking edge.
3) Direct Deck applications only.
Attachment Resistance Expressed as a Moment for Adhesive or Mortar Set
Paddy Average Paddy
1
Roof Tile AdhesiveProduct ApprovalM (ft-lbf)
f
CountWeight (grams)
Dow NOA 16-0222.01 2 13.9 31.3
Bermuda,
2 8 31.3
Planation and
ICP Adhesives Polyset AH-160 NOA 17-0322.03 1 24 40.4
Saxony 900
1 45 118.9
2 8 59.0
NOA 17-0829.12 1 24 45
-Component
Saxony 900
1 45 93
Premix Marbletite, Inc. TILE-TITE NOA 17-1016.07 N/A N/A 43.9
NOA 16-0222.01 2 11.4 26.1
2 8 26.1
ICP Adhesives Polyset AH-160 NOA 17-0322.03 1 24 45.5
Villa 900
1 54 86.61
Premix Marbletite, Inc. TILE-TITE NOA 17-1016.07 N/A N/A 20.6
2 8 55
Villa 900 NOA 17-0829.12 1 30 40
-Component
1 60 70
BOR18003.1 FL28328-R1 Page 10 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
BORAL ROOFING LLC
A CREEK Concrete Roof Tiles
Technical Services, LLC
Attachment Resistance Expressed as a Moment for Adhesive or Mortar Set
Paddy Average Paddy
1
Roof Tile AdhesiveProduct ApprovalM (ft-lbf)
f
CountWeight (grams)
NOA 16-0222.01 2 10.7 29.3
Barcelona 900,
2 8 29.3
Galena Spanish
ICP Adhesives Polyset AH-160 NOA 17-0322.03 1 24 38.7
1 63 66.5
Premix Marbletite, Inc. TILE-TITE NOA 17-1016.07 N/A N/A 24.5
2 8 66.0
Barcelona 900 NOA 17-0829.12 1 30 63
-Component
1 60 82
Notes: 1)
L ABELING
1)
ağƓǒŅğĭƷǒƩĻķ źƓ \[ğƉĻ ğƌĻƭͲ C\[
ağƓǒŅğĭƷǒƩĻķ źƓ hƉĻĻĭŷƚĬĻĻͲ C\[
OR
BOR18003.1 FL28328-R1 Page 11 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
BORAL ROOFING LLC
A CREEK Concrete Roof Tiles
Technical Services, LLC
L IMITATIONS
1)Fire Classification is not within the scope of this evaluation.
2)Installation of the evaluated products shall comply with FBC Section 1507.3, FRSA/TRI Florida High Wind
Concrete and Clay Roof Tile Installation Manual, Fifth Edition Revised
application instructions. Installations in the HVHZ shall comply with RAS 118, RAS119 and RAS 120.
3)All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
4)All product listed in this shall tested quarterly in accordance with TAS 112 Appendix A.
5)Installation of the evaluated products shall be limited to projects in areas subjected to weathering indices of
50or greater as illustrated in ASTM C 1492-03, figure 1 (see below).
C OMPLIANCE S TATEMENT
The products evaluated herein by Zachary R Priest P.E. have demonstrated compliance with the Florida Building
th
Code, 6 Edition (2017)as evidenced in the referenced documents submitted by the named manufacturer.
312:/13/2
:!21;21;33!
.16(11(
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
C ERTIFICATION OF I NDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does nothave, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
E ND OF R EPORT
BOR18003.1FL28328-R1Page 12 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.