DRAWINGS
BQQSPWFE
BQQSPWFE
GJSF
TUSVDUVSF
TzmwftusjK!1801:03132
dmjofl!1801903132
CASTILLO ENGINEERING
NEFF RESIDENCE
SERVICES, LLC
COA # 28345
620 N. WYMORE ROAD,
SUITE 250,
7.40 kW PV SYSTEM
MAITLAND, FL 32751
TEL: (407) 289-2575
BQQSPWFE
ERMOCRATES E. CASTILLO - FL PE 52590
FMFDUSJD
23 SWALLOW DR.
COPYRIGHTED BY
CASTILLO ENGINEERING
cbmvzpun!1801903132
SERVICES, LLC
BOYNTON BEACH, FL 33436
REVISIONS
DESCRIPTIONDATEREV
PROJECT INSTALLER
PROJECT DESCRIPTION:CODES AND STANDARDSOWNERHOUSE PHOTO
GOVERNING CODES :
NEFF, PATCICK
20x370SILFAB: SIL-370 BK (370W) MODULES
FLORIDA RESIDENTIAL CODE, 7TH EDITION 2020 (FRC)
PROJECT SITES
ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES
FLORIDA PLUMBING CODE, 7TH EDITION 2020 (FPC)
SYSTEM SIZE:7.400 kW DC STC
FLORIDA BUILDING CODE, 7TH EDITION 2020 (FBC)
INSTALLER
ARRAY AREA #1:392.41 SQ. FT.
FLORIDA MECHANICAL CODE, 7TH EDITION 2020 (FMC)
Ejhjubmmz
NATIONAL ELECTRICAL CODE 2017 (NEC)
Signature with Seal
tjhofe!cz;
PRO E
ASCE 7-16
Fsnpdsbuft
290 Springview Commerce Drive
FLORIDA FIRE PREVENTION CODE, 7TH EDITION 2020 (FFPC)
F!Dbtujmmp
3 Debary FL 32713
Ebuf;
EQUIPMENT SUMMARY
PH: (321) 356-0249
3132/18/18
20SILFAB: SIL-370 BK (370W) MODULES
24;59;41
20ENPHASE: IQ7PLUS-72-2-US MICROINVERTERS
01TESLA BACKUP GATEWAY 2
ENGINEER
01TESLA POWERWALL 2
PROJECT NAME
Castillo Engineering Services LLC
620 N. Wymore Road, Suite 250, Maitland, FL 32751
RACKING: QRAIL LIGHT
TEL: (407) 289-2575
ATTACHMENT: QUICKMOUNT QMLM
Ermocrates E. Castillo
DESIGN FACTORS:
License#: FL PE 52590
WIND SPEED (ULT): 170
WIND SPEED (ASD): 132
SHEET INDEX
RISK CATEGORY:II
EXPOSURE:C
VICINITY MAP
AUTHORITY HAVING JURISDICTION:
BOYNTON BEACH COUNTY
NOTES AND DESCRIPTION
ROOF PLAN
PROJECT SITE
STRUCTURAL CERTIFICATION:ELECTRICAL CERTIFICATION:
SHEET NAME
COVER SHEET
IERMOCRATESCASTILLOPE#52590ANENGINEERIERMOCRATESCASTILLOPE#52590ANENGINEER
LICENSEDPURSUANTTOCHAPTER471,CERTIFYLICENSEDPURSUANTTOCHAPTER471,CERTIFY
SHEET SIZE
THATTHEINSTALLATIONOFTHEMODULESISINTHATTHEPVELECTRICALSYSTEMAND
ANSI B
COMPLIANCEWITHFBC:RESIDENTIAL2020,ELECTRICALCOMPONENTSAREDESIGNEDAND
CHAPTER3.BUILDINGSTRUCTUREWILLSAFELYAPPROVED USING THE STANDARDS CONTAINED IN
11" X 17"
ACCOMMODATEWINDLATERALANDUPLIFTTHEMOSTRECENTVERSIONOFTHEFLORIDA
FORCES, AND EQUIPMENT DEAD LOADS.BUILDING CODE. FBC 107.
SHEET NUMBER
G-01
{ǤƭƷĻƒ 5ĻƭĭƩźƦƷźƚƓ{ǤƭƷĻƒ 5ĻƭĭƩźƦƷźƚƓ{ǤƭƷĻƒ 5ĻƭĭƩźƦƷźƚƓ
Symbols:Symbols:Symbols:Abbreviations:
BQQSPWFEBQQSPWFEBQQSPWFE
BQQSPWFE
BQQSPWFEBQQSPWFE
GJSFGJSFGJSF
TUSVDUVSF
dmjofl!1801903132
TzmwftusjK!1801:03132
FMFDUSJD
Thissystemisagrid-tied,PVsystem,withPVgenerationconsistingof
AC Alternating Current
Sheet where
CASTILLO ENGINEERING
cbmvzpun!1801903132
section is located
SERVICES, LLC
X
combinedSTCrateddcoutput
20x370SILFAB:SIL-370BK(370W)Moduleswitha
Section..............
COA # 28345
X-XX
ACD AC Disconnect
620 N. WYMORE ROAD,
powerofW.Themodulesareconnectedinto
7,40020Enphase:IQ7PLUS-72-2-US
SUITE 250,
MAITLAND, FL 32751
Detail ID Letter Theinverterhaselectronicmaximumpowerpointtrackingto
microinverters.
APPROX Approximate
TEL: (407) 289-2575
X
ERMOCRATES E. CASTILLO - FL PE 52590
Elevation ...........
Sheet where
maximizeenergycapturedbythePVmodules.Theinverteralsohasaninternal
X-XX
section is located
AWG American Wire Gauge COPYRIGHTED BY
groundfaultdetectionandinterruptiondevicethatissettodisconnectthearrayin
CASTILLO ENGINEERING
Detail ID Letter
SERVICES, LLC
theeventthatagroundfaultthatexceedsoneampereshouldoccur.Theinverter
BAT
Battery
X
Detail ................
REVISIONS
Sheet where
X-XX
hasDCandACdisconnectintegratedsystemandlabelsareprovidedasrequiredby
section is located
CB Combiner Box
DESCRIPTIONDATEREV
the bğƷźƚƓğƌ 9ƌĻĭƷƩźĭğƌ /ƚķĻ
Detail ID Letter
Detail ................
DC Direct Current
X
Area to be enlarged
(Enlarged Plan)
X-XX
Whenthesunisshining,powerfromthePVarrayisfedintotheinverter,
DISC Disconnect
Sheet where
whereitisconvertedfromDCtoAC.Theinverteroutputisthenusedto
section is located
(E) Existing
contributetothepowerrequirementsoftheoccupancy.IfPVpowermeetsthe
PROJECT INSTALLER
Keyed Notes ..........
1
Keyed note designation
requirementsoftheloadsoftheoccupancy,anyremainingPVpowerissoldback
on applicable sheet
EL Elevation
totheutility.Whenutilitypowerisavailable,butPVpowerisnotavailable,
EQ Equal
building loads are supplied by the utility.
Ground Terminal .....
GP
Generation Panel
PV Modules
Grounding Point/rod....
JB Junction Box
Ejhjubmmz
Microinverters Signature with Seal
tjhofe!cz;
Junction
Point of
Fsnpdsbuft
MCB Main Combiner Box
Box
Utility
F!Dbtujmmp
Solar Panel ......... or
00
Module with Source
Ebuf;
Connection
MFR Manufacturer
Circuit number
3132/18/18
24;59;42
Utility Meter
Figure 1: PV System Block Diagram
MID Microgrid Interconnect Device
Combiner Box ..........
CB
MIN Minimum
PROJECT NAME
The inverter meets the requirements of IEEE 1547 and UL 1741.
MISC Miscellaneous
AC Disconnect ..........
ACD
Main Distribution Panel
MDP
Main Distribution
(N) New
MDP
Panel ......................
FALL PROTECTION:
NAVD North American Vertical datum
ANCHORAGES USED FOR ATTACHMENT OF PERSONAL FALL ARREST EQUIPMENT
Fuse ......................
MUSTBEINDEPENDENTOFANYANCHORAGEBEINGUSEDTOSUPPORTOR
OCPD OverCurrent Protection Device
SUSPENDPLATFORMS,ANDCAPABLEOFSUPPORTINGATLEAST5,000POUNDS
PER EMPLOYEE ATTACHED, OR MUST BE DESIGNED AND USED AS FOLLOWS:
POCC Point Of Common Coupling
Overcurrent Breaker ..
AS PART OF A COMPLETE PERSONAL FALL ARREST SYSTEM WHICH
PV Photovoltaic MAINTAINS A SAFETY FACTOR OF AT LEAST TWO.
UNDER THE SUPERVISION OF A QUALIFIED PERSON
Inverter ....................
SF Squarefoot/feet
ADDITIONAL INFORMATION
STC Standard Test Conditions
29 CFR 1926 SUBPART M, FALL PROTECTION. OSHA STANDARD.
Transformer .............
1926.502, FALL PROTECTION SYSTEMS CRITERIA AND PRACTICES
Soladeck
SD
1926.502(D)(15)
Automatic ...............
SHEET NAME
TBD To Be Determined
ATS
39.98"
Transfer Switch
NOTES AND
TYP Typical
DESCRIPTION
Vent, Attic fan
ALLOWABLE/DESIGN PRESSUREPSF
(Roof obstruction)
UNO
Unless Noted Otherwise
DOWN PRESSURE79.3
SHEET SIZE
PV Roof Attachment
RAILS IN THIS
Utility meter UPLIFT PRESSURE, 2 RAILS
79.3
UM
POSITION UNO
ANSI B
Trusses
11" X 17"
Conduit
VIF Verify In Field
Fire Access
SHEET NUMBER
SILFAB: SIL-370 BK
WP Weather Proof
(370W) MODULES
A-00
BQQSPWFE
BQQSPWFE
GJSF
TUSVDUVSF
TzmwftusjK!1801:03132
dmjofl!1801903132
CASTILLO ENGINEERING
SERVICES, LLC
COA # 28345
620 N. WYMORE ROAD,
SUITE 250,
MAITLAND, FL 32751
TEL: (407) 289-2575
ERMOCRATES E. CASTILLO - FL PE 52590
COPYRIGHTED BY
CASTILLO ENGINEERING
SERVICES, LLC
BQQSPWFE
REVISIONS
FMFDUSJD
(E) UTILITY METER
DESCRIPTIONDATEREV
cbmvzpun!1801903132
(E) MAIN DISTRIBUTION PANEL
(N) TESLA BACKUP GATEWAY 2
(N) (01) TESLA POWERWALL 2
(N) AC DISCONNECT (IF REQUIRED)
(N) PRODUCTION METER (IF REQUIRED)
PROJECT INSTALLER
(N) ENPHASE IQ COMBINER BOX
FIRE ACCESS AND PATHWAYS
Ejhjubmmz
AS PER NFPA 11.12.2
Signature with Seal
tjhofe!cz;
Fsnpdsbuft
F!Dbtujmmp
Ebuf;
3132/18/18
24;59;42
PROJECT NAME
3/4" IMC, RMC, FMC, LFMC, PVC,
HDPE, NUCC, RTRC, LFNC, FMT,
ENT OR EMT CONDUIT RUN
(N) SOLADECK
ROOF #1
(20) SILFAB: SIL-370 BK (370W)
MODULES
(N) (20) ENPHASE: IQ7PLUS-72-2-US
MICROINVERTERS
SHEET NAME
ROOF PLAN
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
SCALE: 1/16" = 1'-0"
A-01
A-01
MODULE TYPE, DIMENSIONS & WEIGHT
ARRAY AREA & ROOF AREA CALC'S
GENERAL INSTALLATION PLAN NOTES:
ROOF
NUMBER OF MODULES = 20 MODULES
BQQSPWFE
ARRAYROOFAREA
1)ROOFATTACHMENTSATTACHMENTSATTACHMENTSTOTOTOSYPSYPSYPTRUSSESTRUSSESTRUSSESSHALLBEINSTALLEDAS
MODULE TYPE =
SILFAB: SIL-370 BK (370W) MODULES
TUSVDUVSF
TRUSSTRUSS
AREAAREACOVERED
ROOFROOF TYPETILTAZIMUTH TzmwftusjK!1801:03132
SHOWN IN SHEET S-02 AND AS FOLLOWS FOR EACH WIND ZONE:
MODULE WEIGHT = 41.89 LBS / 19.0 KG.
SIZESPACING
CASTILLO ENGINEERING
(sq.Ft.)BY ARRAY
(Sq. Ft.)
MODULE DIMENSIONS = 70.67" x 39.98" = 19.62 SF
SERVICES, LLC
(%)
UNIT WEIGHT OF ARRAY = 2.13 PSF
COA # 28345
NON - EXPOSED MODULESEDGE / EXPOSED MODULES
620 N. WYMORE ROAD,
#1ASPHALT SHINGLE392.411127.6934.8026.62"X4"24" O.C.
SUITE 250,
WIND
MAITLAND, FL 32751
ZONES
TEL: (407) 289-2575
ERMOCRATES E. CASTILLO - FL PE 52590
BQQSPWFE
SPANCANTILEVERSPANCANTILEVER
GJSF
COPYRIGHTED BY
dmjofl!1801903132
CASTILLO ENGINEERING
ZONE 14' - 0"1' - 4"2' - 0"0' - 8"
SERVICES, LLC
ZONE 1'XXXX
REVISIONS
2' - 0"0' - 8"2' - 0"
ZONE 2eX
DESCRIPTIONDATEREV
ZONE 2nXXX1' - 4"
ZONE 2r2' - 0"0' - 8"2' - 0"0' - 8"
ZONE 3e2' - 0"0' - 8"2' - 0"0' - 8"
ZONE 3rXXXX
PROJECT INSTALLER
SEE SHEET S-02.1 FOR SUPPORTING CALCULATIONS.
2) EXISTING RESIDENTIAL BUILDING IS AN ASPHALT SHINGLE ROOF
WITHMEANROOFHEIGHTIS15FTANDSYP2"X4"ROOFTRUSSES
SPACED24"O.C.EXISTINGROOFSLOPEFORSOLARSYSTEM
RETROFITIS26.6DEGREES.CONTRACTORTOFIELDVERIFYAND
SHALLREPORTTOTHEENGINEERIFANYDISCREPANCIES
Ejhjubmmz
EXIST BETWEEN PLANS AND IN FIELD CONDITIONS.
Signature with Seal
tjhofe!cz;
Fsnpdsbuft
3) FIRE SETBACK TO BE 3' FROM RIDGES AND EDGES, AND 18"EACH
F!Dbtujmmp
WAY FROM HIPS AND VALLEYS PER NFPA 11.12.2
Ebuf;
3132/18/18
*ICERTIFYTHATTHEINSTALLATIONOFTHEMODULESISIN
24;59;43
COMPLIANCEWITHFBC:RESIDENTIALCHAPTER3.BUILDING
STRUCTUREWILLSAFELYACCOMMODATELATERALANDUPLIFT
WIND LOADS AND EQUIPMENT DEAD LOADS. *
PROJECT NAME
MODULE FRAME
DYNORAXX DYNOBOND
SEE SPEC. SHEET/DS-08
ROOF #1
(20) SILFAB: SIL-370 BK (370W)
MODULES
(N) (20) ENPHASE: IQ7PLUS-72-2-US
MICROINVERTERS
(N) QRAIL LIGHT (TYP.)
(44) PV ROOF ATTACHMENT
@ 24" & 48" O.C. MAX.
PV MODULE
(SEE SHEET S-02 FOR
ATTACHMENT DETAIL)
LEGEND
(SEE SHEET S-01.1 FOR PARTIAL
PRESSURE OF THE MODULE)
- WIND ZONE 1 (TYP)
SHEET NAME
- WIND ZONE 2e (TYP)
-
WIND ZONE 2n (TYP)
SHEET SIZE
- WIND ZONE 2r (TYP)
ANSI B
11" X 17"
-
WIND ZONE 3r (TYP)
SHEET NUMBER
- WIND ZONE 3e (TYP)
S-01SCALE: 3/32" = 1'-0"
S-01
FOR EXPOSED MODULESFOR EXPOSED MODULESFOR EXPOSED MODULES
BQQSPWFE
BQQSPWFE
GJSF
TUSVDUVSF
dmjofl!1801903132
TzmwftusjK!1801:03132
CASTILLO ENGINEERING
SERVICES, LLC
COA # 28345
620 N. WYMORE ROAD,
SUITE 250,
MAITLAND, FL 32751
TEL: (407) 289-2575
ERMOCRATES E. CASTILLO - FL PE 52590
COPYRIGHTED BY
CASTILLO ENGINEERING
FOR NON-EXPOSED MODULES
SERVICES, LLC
REVISIONS
DESCRIPTIONDATEREV
PROJECT INSTALLER
ALLOWABLE MODULE UPLIFT PRESSURE 2 RAILS : 79.3 PSF
Ejhjubmmz
Signature with Seal
tjhofe!cz;
Fsnpdsbuft
F!Dbtujmmp
Ebuf;
3132/18/18
24;59;43
PROJECT NAME
2h
2
0.5h
ROOF #1
LEGEND
(20) SILFAB: SIL-370 BK (370W)
MODULES
-
EXPOSED MODULE
- EDGE MODULE
- NON- EXPOSED MODULE
- MISSING MODULE
- MIN. MODULE EDGE DISTANCE LINE
- MODULE EXPOSURE LINE
-
WIND ZONE 1 (TYP)
SHEET NAME
-
2hDISTANCE : 0' - 10"WIND ZONE 2e (TYP)
2
0.5hDISTANCE : 7' - 6"
- WIND ZONE 2n (TYP)
NOTE:PARTIALPRESSURESOFTHEWINDZONESON
SHEET SIZE
ALLMODULESHAVEBEENVERIFIEDANDAREWITHIN
-
WIND ZONE 2r (TYP)
ANSI B
THEALLOWABLEPERTHEMANUFACTURER
SPECIFICATION,INSTALLERSHOULDFOLLOWTHE
11" X 17"
- WIND ZONE 3r (TYP)
LAYOUTTOAVOIDHIGHERZONALPARTIAL
SHEET NUMBER
PRESSURES.ANYCHANGESINLAYOUTSHOULDBE
-
WIND ZONE 3e (TYP)
REPORTEDBACKTOTHEENGINEEROFRECORD.
S-01.1SCALE: 1/8" = 1'-0"
S-01.1
BQQSPWFE
h
GJSF
BQQSPWFE
dmjofl!1801903132
TUSVDUVSF
(E) ASPHALT SHINGLE
TzmwftusjK!1801:03132
CASTILLO ENGINEERING
ROOF
GROUNDING END CLAMP
SERVICES, LLC
COA # 28345
620 N. WYMORE ROAD,
SUITE 250,
MAITLAND, FL 32751
SOLAR MODULE
TEL: (407) 289-2575
ERMOCRATES E. CASTILLO - FL PE 52590
COPYRIGHTED BY
CASTILLO ENGINEERING
SEE (2/S-02) FOR
SERVICES, LLC
ENLARGED VIEW
REVISIONS
DESCRIPTIONDATEREV
DYNOBOND JUMPER
TRUSSES
(E)2"X4" @ 24" O.C.
PROJECT INSTALLER
S-02SCALE: 1'' = 1' - 0''
HIDDEN END CLAMP AND SKIRT
Ejhjubmmz
(OPTIONAL)
Signature with Seal
tjhofe!cz;
Fsnpdsbuft
F!Dbtujmmp
Ebuf;
GROUNDING MID CLAMP 3132/18/18
(N) CAP SCREW, HEX
24;59;44
HEAD, 5/16-18X1"
UNC-2A,18-8 SS
PROJECT NAME
QUICK MOUNT L FOOT
QUICKMOUNT QMLM
B FLASHING
2"X4" TRUSS SPANNER FOR
MISSED TRUSS ATTACHMENT
(IF REQUIRED)
QRAIL LIGHT (TYP)
SHEET NAME
SHEET SIZE
5/16"DIA. X 2.5"MIN.
EMBEDMENT LAG SCREW
(E) 2"X4"TRUSSES @ 24" O.C.
ANSI B
AT EACH ATTACHMENT POINT
11" X 17"
INTO EXISTING FRAMING
SHEET NUMBER
S-02
S-02
SCALE: 1"=2"
BQQSPWFE
GJSF
BQQSPWFE
dmjofl!1801903132
TUSVDUVSF
TzmwftusjK!1801:03132
CASTILLO ENGINEERING
SERVICES, LLC
COA # 28345
620 N. WYMORE ROAD,
SUITE 250,
MAITLAND, FL 32751
TEL: (407) 289-2575
ERMOCRATES E. CASTILLO - FL PE 52590
COPYRIGHTED BY
CASTILLO ENGINEERING
SERVICES, LLC
REVISIONS
DESCRIPTIONDATEREV
PROJECT INSTALLER
Ejhjubmmz
Signature with Seal
tjhofe!cz;
Fsnpdsbuft
F!Dbtujmmp
Ebuf;
3132/18/18
24;59;44
PROJECT NAME
SHEET NAME
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
S-02.1
SOLAR ARRAY (SOLAR ARRAY (SOLAR ARRAY (7.4007.4007.400 kW-DC STC) kW-DC STC) kW-DC STC)
BQQSPWFE
(((202020) ) ) SILFABSILFABSILFAB: : : SIL-370 BKSIL-370 BKSIL-370 BK ( ( (370370370W) MODULES
GJSF BQQSPWFEBQQSPWFE
TUSVDUVSF
(02) BRANCH OF 10 MODULES
dmjofl!1801903132
TzmwftusjK!1801:03132
CASTILLO ENGINEERING
BQQSPWFE
NOTE:
SERVICES, LLC
1.SUBJECTPVSYSTEMSHASBEENDESIGNEDTOMEETTHE
FMFDUSJD
COA # 28345
REQUIREMENTSOFTHENEC2017,ANDTHOSESETFORTHBYTHE
620 N. WYMORE ROAD,
cbmvzpun!1801903132
FLORIDASOLARENERGYCENTERCERTIFICATION,INCLUDING
SUITE 250,
MAITLAND, FL 32751
MAXIMUMNUMBEROFMODULESTRINGS,MAXIMUMNUMBEROF
TEL: (407) 289-2575
MODULESPERSTRING,MAXIMUMOUTPUT,MODULE
ERMOCRATES E. CASTILLO - FL PE 52590
Q CABLE
MANUFACTURERANDMODELNUMBER,INVERTERMANUFACTURER
COPYRIGHTED BY
AND MODEL NUMBER, AS APPLICABLE.
CASTILLO ENGINEERING
SERVICES, LLC
ENPHASE: IQ7PLUS-72-2-US
REVISIONS
MICROINVERTERS
DESCRIPTIONDATEREV
PV MODULES
PROJECT INSTALLER
INTERCONNECTION
120% RULE - CEC 705.12(B)(2)(3)(b)
UTILITY FEED + SOLAR BACKFEED
200A + 40A = 240A
BUSS RATING x 120%
200A x 120% = 240A
(N) SOLADECK
600 V, NEMA 3R
UL LISTED
Ejhjubmmz
Signature with Seal
tjhofe!cz;
Fsnpdsbuft
F!Dbtujmmp
Ebuf;
3132/18/18
TO UTILITY GRID
24;59;45
(3) 10/2 ROMEX RUN IN ATTIC
(N) AC DISCONNECT:
L1L2N
OR
240V, 60AMP RATED,
(3) #10 AWG THWN-2 - RED
(N) 125A ENPHASE IQ COMBINER 3
NEMA 3R, UL LISTED
BI-DIRECTIONAL
(3) #10 AWG THWN-2 - BLACK
(N) PV METERPROJECT NAME
(X-IQ-AM1-240-3) \[WITH UPTO (4)
LOCKABLE & NON-FUSED
UTILITY METER
EGC #8 AWG THWN-2
(IF REQUIRED)
2-POLE BREAKERS AND ENVOY
(IF REQUIRED)
1-PHASE, 240V
IN 3/4" PVC, IMC, RMC, FMC,
COMMUNICATION GATEWAY\]
LFMC, HDPE, NUCC, RTRC,
L1L2N
LFNC, EMT, FMT OR ENT
L1L1L1
L1L1
(E) MAIN DISTRIBUTION
CONDUIT RUN
L2
PANEL, 200A RATED, 240V
L2L2
L2L2
NNN
NN
GGG
GG
(E) MAIN BREAKER
10A
200A/2P, 240V
(3) #8AWG THWN-2
(1) #10 AWG THWN-2 GND
L1L1
IN 3/4" PVC, IMC, RMC, FMC,
L2L2
LFMC, HDPE, NUCC, RTRC,
LFNC, EMT, FMT, ENT
L1L1
CONDUIT RUN
20A/2P
L2L2
L1
40A/2P
L2
L1L1
20A/2P
L1
L2L2
L2
SHEET NAME
N
ELECTRICAL
G
LINE DIAGRAM
NG
G
EXISTING GROUNDING
ELECTRODE SYSTEM
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
SCALE: NTS
E-01
E-01
SOLAR ARRAY (SOLAR ARRAY (SOLAR ARRAY (7.4007.4007.400 kW-DC STC) kW-DC STC) kW-DC STC)
(((202020) ) ) SILFABSILFABSILFAB: : : SIL-370 BKSIL-370 BKSIL-370 BK ( ( (370370370W) MODULES
BQQSPWFE
BQQSPWFEBQQSPWFE
GJSF
TUSVDUVSF
(02) BRANCH OF 10 MODULES
dmjofl!1801903132
TzmwftusjK!1801:03132
CASTILLO ENGINEERING
NOTE:
SERVICES, LLC
1.SUBJECTPVSYSTEMSHASBEENDESIGNEDTOMEETTHE
COA # 28345
REQUIREMENTSOFTHENEC2017,ANDTHOSESETFORTHBYTHE
620 N. WYMORE ROAD,
FLORIDASOLARENERGYCENTERCERTIFICATION,INCLUDING
SUITE 250,
MAITLAND, FL 32751
MAXIMUMNUMBEROFMODULESTRINGS,MAXIMUMNUMBEROF
TEL: (407) 289-2575
MODULESPERSTRING,MAXIMUMOUTPUT,MODULE
ERMOCRATES E. CASTILLO - FL PE 52590
Q CABLE
MANUFACTURERANDMODELNUMBER,INVERTERMANUFACTURER
COPYRIGHTED BY
AND MODEL NUMBER, AS APPLICABLE.
CASTILLO ENGINEERING
2.PROVIDETAPBOXINCOMPLIANCEWITHNEC312.8IFPANEL
SERVICES, LLC
GUTTER SPACE IS INADEQUATE.
ENPHASE: IQ7PLUS-72-2-US
3.IFTHEFUSEDACDISCONNECTWIRERUNEXCEEDS10FTFROM
REVISIONS
MICROINVERTERS
THEPOINTOFINTERCONNECTION,CABLELIMITERSOR
DESCRIPTIONDATEREV
CURRENT-LIMITEDCIRCUITBREAKERSMUSTBEINSTALLEDFOR
PV MODULES
EACH UNGROUNDED CONDUCTOR PER NEC 705.31.
(2) #1/0 AWG THWN-2
(1) #1/0 AWG THWN-2 NTL
PROJECT INSTALLER
IN 3/4" IMC, RMC, FMC, LFMC,
PVC, HDPE, NUCC, RTRC,
LFNC, FMT, ENT, OR EMT
(N) 200A TESLA BACKUP GATEWAY 2
CONDUIT RUN
AUTOMATIC TRANSFER SWITCH
MICROGRID INTERCONNECT DEVICE
UL LISTED, SER RATED
TO UTILITY GRID
(N) SOLADECK
(N) (1) TESLA POWERWALL 2
LINE TAP USING INSULATION
600 V, NEMA 3R
BATTERIES
PIERCING PER NEC 705.12(A)
UL LISTED
Ejhjubmmz
L1L2N
5KW CONTINUOUS POWER
L1L2N
Signature with Seal
13.5KWH STORAGE
tjhofe!cz;
Fsnpdsbuft
(N) MAIN
BI-DIRECTIONAL
SERVICE
F!Dbtujmmp
UTILITY METER
GNL2L1
DISCONNECT
Ebuf;
1-PHASE, 240V
30A/2P 200A/2P, 240V
3132/18/18
L1
(E) MAIN DISTRIBUTION
24;59;45
L2 L1L2N
(3) 10/2 ROMEX RUN IN ATTIC
PANEL, 200A RATED,
40A/2P
OR
240V.
L1
(3) #10 AWG THWN-2 - RED
(N) 125A ENPHASE IQ COMBINER 3
L2
(3) #10 AWG THWN
(3) #10 AWG THWN-2 - BLACK
PROJECT NAME
(X-IQ-AM1-240-3) \[WITH UPTO (4)
(1) #10 AWG THWN-2 GND
EGC #8 AWG THWN-2
N
2-POLE BREAKERS AND ENVOY IN 3/4" IMC, RMC, FMC, LFMC,
(E) MAIN BREAKER
IN 3/4" PVC, IMC, RMC, FMC,
PVC, HDPE, NUCC, RTRC,
G
COMMUNICATION GATEWAY\]
L1L1L2L2
200A/2P, 240V
LFMC, HDPE, NUCC, RTRC,
LFNC, FMT, ENT, OR EMT
LFNC, EMT, FMT OR ENT
CONDUIT RUN
L1
N
CONDUIT RUN
L2
G
N
G
L1L1
10A
L2L2
L1L2NG
L1L1
L2L2
(N) AC DISCONNECT:
150A/2P
L1L1
240V, 60AMP RATED,
NEMA 3R, UL LISTED
L2L2
(N) PV METER
LOCKABLE & NON-FUSED
L1L1
(IF REQUIRED)
(IF REQUIRED)
L2L2
20A/2P
N
L1
L1L1
L1L1
L1L1
L2
G
L2L2
20A/2P
L2L2
L2L2
L1
EXISTING GROUNDING
NN
NN
N
L2
ELECTRODE SYSTEM
SHEET NAME
G
GG
GG
(N) 150A BACKUP PANEL
(2) #1/0 AWG THWN-2
ELECTRICAL
120/240VAC
(1) #1/0 AWG THWN-2 NTL
LINE DIAGRAM
(1) #6 AWG THWN-2 GND
NG
G
IN 3/4" IMC, RMC, FMC, LFMC,
PVC, HDPE, NUCC, RTRC,
(3) #8 AWG THWN-2
SHEET SIZE
LFNC, FMT, ENT, OR EMT
(1) #10 AWG THWN-2 GND
CONDUIT RUN
IN 3/4" PVC, IMC, RMC, FMC,
ANSI B
LFMC, HDPE, NUCC, RTRC,
11" X 17"
LFNC, EMT, FMT, ENT
CONDUIT RUN
SHEET NUMBER
GPS!SFGFSFODF!POMZ
SCALE: NTS
E-01.1
E-01.1
ELECTRICAL CALCULATIONELECTRICAL CALCULATIONELECTRICAL CALCULATION
BQQSPWFE
ELECTRICAL NOTESELECTRICAL NOTESELECTRICAL NOTES
GJSF
dmjofl!1801903132
BQQSPWFEBQQSPWFE
BQQSPWFEBQQSPWFE
TUSVDUVSF
1.ALLEQUIPMENTTOBELISTEDLISTEDLISTEDBYBYBYULULULOROROROTHEROTHEROTHERNRTL,ANDLABELED
FMFDUSJD TzmwftusjK!1801:03132
FOR ITS APPLICATION.
CASTILLO ENGINEERING
cbmvzpun!1801903132
SERVICES, LLC
2.ALLCONDUCTORSSHALLBECOPPER,RATEDFOR600VAND90
COA # 28345
DEGREECWETENVIRONMENT.THETERMINALSARERATEDFOR75
620 N. WYMORE ROAD,
SUITE 250,
DEGREE C.
MAITLAND, FL 32751
TEL: (407) 289-2575
3.THE WIRES ARE SIZED ACCORDING TO NEC 110.14.
ERMOCRATES E. CASTILLO - FL PE 52590
4.WIRING,CONDUIT,ANDRACEWAYSMOUNTEDONROOFTOPSSHALL
COPYRIGHTED BY
BEROUTEDDIRECTLYTO,ANDLOCATEDASCLOSEASPOSSIBLETO
CASTILLO ENGINEERING
THE NEAREST RIDGE, HIP, OR VALLEY.
SERVICES, LLC
5.WORKINGCLEARANCESAROUNDALLNEWANDEXISTINGELECTRICAL
REVISIONS
EQUIPMENT SHALL COMPLY WITH NEC 110.26.
DESCRIPTIONDATEREV
6.DRAWINGSINDICATETHEGENERALARRANGEMENTOFSYSTEMS.
CONTRACTORSHALLFURNISHALLNECESSARYOUTLETS,SUPPORTS,
FITTINGSANDACCESSORIESTOFULFILLAPPLICABLECODESAND
STANDARDS.
7.WHERESIZESOFJUNCTIONBOXES,RACEWAYS,ANDCONDUITSARE
NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY.
PROJECT INSTALLER
8.ALLWIRETERMINATIONSSHALLBEAPPROPRIATELYLABELEDAND
READILY VISIBLE.
9.MODULEGROUNDINGCLIPSTOBEINSTALLEDBETWEENMODULE
FRAMEANDMODULESUPPORTRAIL,PERTHEGROUNDINGCLIP
MANUFACTURER'S INSTRUCTION.
10.MODULESUPPORTRAILTOBEBONDEDTOCONTINUOUSCOPPER
G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG.
Ejhjubmmz
Signature with Seal
11.THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE .
tjhofe!cz;
12.UTILITYHAS24-HRUNRESTRICTEDACCESSTOALL
Fsnpdsbuft
PHOTOVOLTAICSYSTEMCOMPONENTSLOCATEDATTHESERVICE
F!Dbtujmmp
Ebuf;
ENTRANCE.
3132/18/18
13.MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.
24;59;46
14.RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.
15.CONDUCTORSEXPOSEDTOSUNLIGHTSHALLBELISTEDASSUNLIGHT
RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.10 (D).
PROJECT NAME
16.CONDUCTORSEXPOSEDTOWETLOCATIONSSHALLBESUITABLEFOR
USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C).
17.THISSYSTEMISEQUIPPEDWITHRAPIDSHUTDOWNOFPV
CONDUCTORS IN COMPLIANCE WITH NEC 690.12.
18.LABELINGINCOMPLIANCEWITHNEC690.12AND690.56(C)ISSHOWN
ON SHEET E-03.
IERMOCRATESCASTILLOPE#52590ANENGINEER
LICENSEDPURSUANTTOCHAPTER471,CERTIFY
THATTHEPVELECTRICALSYSTEMANDELECTRICAL
SHEET NAME
COMPONENTSAREDESIGNEDANDAPPROVEDUSING
THESTANDARDSCONTAINEDINTHEMOSTRECENT
VERSION OF THE FLORIDA BUILDING CODE. FBC 107.
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
E-02
PHOTOVOLTAIC SYSTEM AC DISCONNECT
BQQSPWFEBQQSPWFEBQQSPWFEBQQSPWFEBQQSPWFEBQQSPWFEBQQSPWFEBQQSPWFEBQQSPWFEBQQSPWFEBQQSPWFEBQQSPWFEBQQSPWFEBQQSPWFEBQQSPWFEBQQSPWFEBQQSPWFEBQQSPWFEBQQSPWFEBQQSPWFEBQQSPWFEBQQSPWFE
!!
WARNINGWARNINGWARNING
BQQSPWFE
FMFDUSJD
TUSVDUVSF
RATED ACOPERATING CURRENT 24.2 AMPS
SOLAR PV SYSTEM EQUIPPEDSOLAR PV SYSTEM EQUIPPED
TzmwftusjK!1801:03132
ELECTRIC SHOCK HAZARD
CASTILLO ENGINEERING
cbmvzpun!1801903132
AC NOMINAL OPERATING VOLTAGE 240 VOLTS
TERMINALS ON BOTH LINE AND
SERVICES, LLC
WITH RAPID SHUTDOWN
LOAD SIDES MAY BE ENERGIZED
COA # 28345
620 N. WYMORE ROAD,
LABEL LOCATION:
IN THE OPEN POSITION
SUITE 250,
AC DISCONNECT, POINT OF INTERCONNECTION
MAITLAND, FL 32751
(PER CODE: NEC 690.54)
LABEL LOCATION:TEL: (407) 289-2575
ERMOCRATES E. CASTILLO - FL PE 52590
AC DISCONNECT, POINT OF INTERCONNECTION
(PER CODE: NEC 690.13(B))
COPYRIGHTED BY
WARNING
TURN RAPID SHUTDOWN
CASTILLO ENGINEERING
INVERTER OUTPUT CONNECTION DO NOT
SWITCH TO THE
SERVICES, LLC
SOLAR ELECTRIC
PV PANELS
"OFF" POSITION TO
!
RELOCATE THIS OVERCURRENT DEVICE REVISIONS
DESCRIPTIONDATEREV
LABEL LOCATION:
SHUT DOWN PV SYSTEM
POINT OF INTERCONNECTION
PER AHJ 7/1/2021 A
LABEL LOCATION:
AND REDUCE
(PER CODE: NEC 705.12(B)(2)(3)(b))
POINT OF INTERCONNECTION
SHOCK HAZARD
(PER CODE: NEC 705.12(B)(2)(3)(b))
IN THE ARRAY
DATA PER PANEL
PROJECT INSTALLER
RAPID SHUTDOWN
NOMINAL OPERATING AC VOLTAGE -
V
240
LABEL LOCATION:
SWITCH FOR
AC DISCONNECT, POINT OF INTERCONNECTION
(PER CODE: NEC 690.56(C)(1)(a), IFC 605.11.3.1(1)
NOMINAL OPERATING AC FREQUENCY-
Hz
60
SOLAR PV SYSTEM
MAXIMUM AC POWER-
VA
290
LABEL LOCATION:
AC DISCONNECT
MAXIMUM AC CURRENT-
A
1.21
(PER CODE: NEC 690.56(C)(3))
EMERGENCY RESPONDER:EMERGENCY RESPONDER:
Ejhjubmmz
Signature with Seal
MAXIMUM OVERCURRENT DEVICE RATING
tjhofe!cz;
A
ADHESIVE FASTENED SIGNS:
20
THIS SOLAR PV SYSTEM IS EQUIPPEDTHIS SOLAR PV SYSTEM IS EQUIPPED
FOR AC MODULE PROTECTION PER CIRCUIT-
THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT Fsnpdsbuft
WHERE IT IS INSTALLED.
F!Dbtujmmp
WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD
WITH RAPID SHUTDOWN.WITH RAPID SHUTDOWN.
Ebuf;
APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD
3132/18/18
COMPLY WITH ANSI Z535.4 \[NEC 110.21(B) FIELD MARKING\].
LABEL LOCATION:
24;59;47
ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF
COMBINER BOX
PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER
TURN RAPID SHUTDOWN SWITCH TO THE ''OFF''TURN RAPID SHUTDOWN SWITCH TO THE ''OFF''
(PER CODE: NEC 690.52)
RESISTANT \[IFC 605.11.1.3\]
POSITION TO SHUTDOWN ENTIRE PV SYSTEMPOSITION TO SHUTDOWN ENTIRE PV SYSTEM
PROJECT NAME
NOTES:
WARNING:
ALL LABELS AND MARKINGS ARE TO BE
REFLECTIVE AND MEET ALL THE
THIS EQUIPMENT FED BY MULTIPLE
REQUIREMENTS OF NFPA 1-11.12
TESLA BACKUP GATEWAY 2
SOURCES. TOTAL RATING OF ALL
TESLA POWERWALL 2
AC DISCONNECT
OVERCURRENT DEVICES, EXCLUDING
PRODUCTION METER
A
UTILITY METER
MAIN SUPPLY OVERCURRENT DEVICE,
ENPHASE IQ COMBINER BOX
MAIN DISTRIBUTION
SHALL NOT EXCEED AMPACITY OF BUSBAR
PANEL
LABEL LOCATION:
POINT OF INTERCONNECTION
(PER CODE: NEC 705.12(B)(2)(3)(c))
WARNING
IN CASE OF EMERGENCY, CONTACT:
PES SOLAR
PH. NO. : (321) 356-0249
PV SOLAR ARRAY
LABEL LOCATION:
SHEET NAME
MAIN DISCONNECT
(PER CODE: NFPA 11.12.2.1.5)
23 SWALLOW DR. BOYNTON BEACH, FL 33436
LABEL LOCATION:
MAIN SERVICE DISCONNECT
SHEET SIZE
(PER CODE : NFPA 1,11.12.2.1)
ANSI B
11" X 17"
BQQSPWFE
SHEET NUMBER
GJSF
dmjofl!1801903132
E-03
BQQSPWFEBQQSPWFEBQQSPWFE
GJSFGJSFGJSF
BQQSPWFE
BQQSPWFE
TUSVDUVSF
dmjofl!1801903132
TzmwftusjK!1801:03132
FMFDUSJD
CASTILLO ENGINEERING
SERVICES, LLC
cbmvzpun!1801903132
COA # 28345
620 N. WYMORE ROAD,
SUITE 250,
MAITLAND, FL 32751
TEL: (407) 289-2575
ERMOCRATES E. CASTILLO - FL PE 52590
COPYRIGHTED BY
CASTILLO ENGINEERING
SERVICES, LLC
REVISIONS
DESCRIPTIONDATEREV
PROJECT INSTALLER
Ejhjubmmz
Signature with Seal
tjhofe!cz;
Fsnpdsbuft
F!Dbtujmmp
Ebuf;
3132/18/18
24;59;47
PROJECT NAME
SHEET NAME
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
DS-01
BQQSPWFE
GJSF
BQQSPWFE
dmjofl!1801903132
TUSVDUVSF
TzmwftusjK!1801:03132
CASTILLO ENGINEERING
SERVICES, LLC
COA # 28345
620 N. WYMORE ROAD,
SUITE 250,
MAITLAND, FL 32751
TEL: (407) 289-2575
ERMOCRATES E. CASTILLO - FL PE 52590
COPYRIGHTED BY
CASTILLO ENGINEERING
SERVICES, LLC
REVISIONS
DESCRIPTIONDATEREV
PROJECT INSTALLER
Ejhjubmmz
Signature with Seal
tjhofe!cz;
Fsnpdsbuft
F!Dbtujmmp
Ebuf;
3132/18/18
24;59;48
PROJECT NAME
SHEET NAME
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
DS-01.1
BQQSPWFE
GJSF
BQQSPWFE
BQQSPWFE
TUSVDUVSF
dmjofl!1801903132
TzmwftusjK!1801:03132
FMFDUSJD
CASTILLO ENGINEERING
SERVICES, LLC
cbmvzpun!1801903132
COA # 28345
620 N. WYMORE ROAD,
SUITE 250,
MAITLAND, FL 32751
TEL: (407) 289-2575
ERMOCRATES E. CASTILLO - FL PE 52590
COPYRIGHTED BY
CASTILLO ENGINEERING
SERVICES, LLC
REVISIONS
DESCRIPTIONDATEREV
PROJECT INSTALLER
Ejhjubmmz
Signature with Seal
tjhofe!cz;
Fsnpdsbuft
F!Dbtujmmp
Ebuf;
3132/18/18
24;59;49
PROJECT NAME
SHEET NAME
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
DS-02
BQQSPWFE
GJSF
BQQSPWFE
dmjofl!1801903132
TUSVDUVSF
BQQSPWFE
TzmwftusjK!1801:03132
CASTILLO ENGINEERINGCASTILLO ENGINEERING
FMFDUSJD
SERVICES, LLCSERVICES, LLC
cbmvzpun!1801903132
COA # 28345COA # 28345
620 N. WYMORE ROAD,620 N. WYMORE ROAD,
SUITE 250,SUITE 250,
MAITLAND, FL 32751MAITLAND, FL 32751
TEL: (407) 289-2575TEL: (407) 289-2575
ERMOCRATES E. CASTILLO - FL PE 52590ERMOCRATES E. CASTILLO - FL PE 52590
COPYRIGHTED BYCOPYRIGHTED BY
CASTILLO ENGINEERINGCASTILLO ENGINEERING
SERVICES, LLCSERVICES, LLC
REVISIONSREVISIONS
DESCRIPTIONDESCRIPTIONDATEDATEREVREV
PROJECT INSTALLERPROJECT INSTALLER
Ejhjubmmz
Signature with SealSignature with Seal
tjhofe!cz;
Fsnpdsbuft
F!Dbtujmmp
Ebuf;
3132/18/18
24;59;4:
PROJECT NAMEPROJECT NAME
SHEET NAMESHEET NAME
SHEET SIZESHEET SIZE
ANSI BANSI B
11" X 17"11" X 17"
SHEET NUMBERSHEET NUMBER
DS-03DS-03
BQQSPWFE
GJSF
BQQSPWFE
dmjofl!1801903132
TUSVDUVSF
TzmwftusjK!1801:03132
CASTILLO ENGINEERINGCASTILLO ENGINEERING
SERVICES, LLCSERVICES, LLC
COA # 28345COA # 28345
620 N. WYMORE ROAD,620 N. WYMORE ROAD,
SUITE 250,SUITE 250,
MAITLAND, FL 32751MAITLAND, FL 32751
TEL: (407) 289-2575TEL: (407) 289-2575
ERMOCRATES E. CASTILLO - FL PE 52590ERMOCRATES E. CASTILLO - FL PE 52590
COPYRIGHTED BYCOPYRIGHTED BY
CASTILLO ENGINEERINGCASTILLO ENGINEERING
SERVICES, LLCSERVICES, LLC
REVISIONSREVISIONS
DESCRIPTIONDESCRIPTIONDATEDATEREVREV
PROJECT INSTALLERPROJECT INSTALLER
Ejhjubmmz
Signature with SealSignature with Seal
tjhofe!cz;
Fsnpdsbuft
F!Dbtujmmp
Ebuf;
3132/18/18
24;59;4:
PROJECT NAMEPROJECT NAME
SHEET NAMESHEET NAME
SHEET SIZESHEET SIZE
ANSI BANSI B
11" X 17"11" X 17"
GPS!SFGFSFODF!POMZ
SHEET NUMBERSHEET NUMBER
DS-04DS-04
BQQSPWFE
BQQSPWFE
GJSF
TUSVDUVSF
TzmwftusjK!1801:03132
dmjofl!1801903132
CASTILLO ENGINEERINGCASTILLO ENGINEERING
SERVICES, LLCSERVICES, LLC
COA # 28345COA # 28345
620 N. WYMORE ROAD,620 N. WYMORE ROAD,
SUITE 250,SUITE 250,
MAITLAND, FL 32751MAITLAND, FL 32751
TEL: (407) 289-2575TEL: (407) 289-2575
ERMOCRATES E. CASTILLO - FL PE 52590ERMOCRATES E. CASTILLO - FL PE 52590
COPYRIGHTED BYCOPYRIGHTED BY
CASTILLO ENGINEERINGCASTILLO ENGINEERING
SERVICES, LLCSERVICES, LLC
REVISIONSREVISIONS
DESCRIPTIONDESCRIPTIONDATEDATEREVREV
PROJECT INSTALLERPROJECT INSTALLER
Ejhjubmmz
Signature with SealSignature with Seal
tjhofe!cz;
Fsnpdsbuft
F!Dbtujmmp
Ebuf;
3132/18/18
24;59;51
PROJECT NAMEPROJECT NAME
SHEET NAMESHEET NAME
SHEET SIZESHEET SIZE
ANSI BANSI B
11" X 17"11" X 17"
GPS!SFGFSFODF!POMZ
SHEET NUMBERSHEET NUMBER
DS-05DS-05
BQQSPWFEBQQSPWFEBQQSPWFE
BQQSPWFEBQQSPWFEBQQSPWFE
GJSFGJSFGJSF
FMFDUSJD
BQQSPWFE
dmjofl!1801903132dmjofl!1801903132dmjofl!1801903132
TUSVDUVSF
cbmvzpun!1801903132
TzmwftusjK!1801:03132
CASTILLO ENGINEERING
SERVICES, LLC
COA # 28345
620 N. WYMORE ROAD,
SUITE 250,
MAITLAND, FL 32751
TEL: (407) 289-2575
ERMOCRATES E. CASTILLO - FL PE 52590
COPYRIGHTED BY
CASTILLO ENGINEERING
SERVICES, LLC
REVISIONS
DESCRIPTIONDATEREV
PROJECT INSTALLER
Ejhjubmmz
Signature with Seal
tjhofe!cz;
Fsnpdsbuft
F!Dbtujmmp
Ebuf;
3132/18/18
24;59;52
PROJECT NAME
SHEET NAME
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
DS-06
BQQSPWFE
GJSF
dmjofl!1801903132
TUSVDUVSF
TzmwftusjK!1801:03132
CASTILLO ENGINEERING
SERVICES, LLC
COA # 28345
620 N. WYMORE ROAD,
SUITE 250,
MAITLAND, FL 32751
TEL: (407) 289-2575
ERMOCRATES E. CASTILLO - FL PE 52590
COPYRIGHTED BY
CASTILLO ENGINEERING
SERVICES, LLC
REVISIONS
DESCRIPTIONDATEREV
PROJECT INSTALLER
Ejhjubmmz
Signature with Seal
tjhofe!cz;
Fsnpdsbuft
F!Dbtujmmp
Ebuf;
3132/18/18
24;59;53
PROJECT NAME
SHEET NAME
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
DS-07
BQQSPWFE
BQQSPWFE
GJSF
TUSVDUVSF
BQQSPWFE
dmjofl!1801903132
TzmwftusjK!1801:03132
FMFDUSJD
CASTILLO ENGINEERING
SERVICES, LLC
cbmvzpun!1801903132
COA # 28345
620 N. WYMORE ROAD,
SUITE 250,
MAITLAND, FL 32751
TEL: (407) 289-2575
ERMOCRATES E. CASTILLO - FL PE 52590
COPYRIGHTED BY
CASTILLO ENGINEERING
SERVICES, LLC
REVISIONS
DESCRIPTIONDATEREV
PROJECT INSTALLER
Ejhjubmmz
Signature with Seal
tjhofe!cz;
Fsnpdsbuft
F!Dbtujmmp
Ebuf;
3132/18/18
24;59;53
PROJECT NAME
SHEET NAME
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
DS-08
CASTILLO ENGINEERING
NEFF RESIDENCE
SERVICES, LLC
COA # 28345
620 N. WYMORE ROAD,
SUITE 250,
7.40 kW PV SYSTEM
MAITLAND, FL 32751
TEL: (407) 289-2575
ERMOCRATES E. CASTILLO - FL PE 52590
23 SWALLOW DR.
COPYRIGHTED BY
CASTILLO ENGINEERING
SERVICES, LLC
BOYNTON BEACH, FL 33436
REVISIONS
DESCRIPTIONDATEREV
PROJECT INSTALLER
PROJECT DESCRIPTION:CODES AND STANDARDSOWNERHOUSE PHOTO
GOVERNING CODES :
NEFF, PATCICK
20x370SILFAB: SIL-370 BK (370W) MODULES
FLORIDA RESIDENTIAL CODE, 7TH EDITION 2020 (FRC)
PROJECT SITES
ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES
FLORIDA PLUMBING CODE, 7TH EDITION 2020 (FPC)
SYSTEM SIZE:7.400 kW DC STC
FLORIDA BUILDING CODE, 7TH EDITION 2020 (FBC)
INSTALLER
ARRAY AREA #1:392.41 SQ. FT.
FLORIDA MECHANICAL CODE, 7TH EDITION 2020 (FMC)
Ejhjubmmz
NATIONAL ELECTRICAL CODE 2017 (NEC)
Signature with Seal
tjhofe!cz;
PRO E
ASCE 7-16
Fsnpdsbuft
290 Springview Commerce Drive
FLORIDA FIRE PREVENTION CODE, 7TH EDITION 2020 (FFPC)
F!Dbtujmmp
3 Debary FL 32713
Ebuf;
EQUIPMENT SUMMARY
PH: (321) 356-0249
3132/18/18
20SILFAB: SIL-370 BK (370W) MODULES
24;59;41
20ENPHASE: IQ7PLUS-72-2-US MICROINVERTERS
01TESLA BACKUP GATEWAY 2
ENGINEER
01TESLA POWERWALL 2
PROJECT NAME
Castillo Engineering Services LLC
620 N. Wymore Road, Suite 250, Maitland, FL 32751
RACKING: QRAIL LIGHT
TEL: (407) 289-2575
ATTACHMENT: QUICKMOUNT QMLM
Ermocrates E. Castillo
DESIGN FACTORS:
License#: FL PE 52590
WIND SPEED (ULT): 170
WIND SPEED (ASD): 132
SHEET INDEX
RISK CATEGORY:II
EXPOSURE:C
VICINITY MAP
AUTHORITY HAVING JURISDICTION:
BOYNTON BEACH COUNTY
NOTES AND DESCRIPTION
ROOF PLAN
PROJECT SITE
STRUCTURAL CERTIFICATION:ELECTRICAL CERTIFICATION:
SHEET NAME
COVER SHEET
IERMOCRATESCASTILLOPE#52590ANENGINEERIERMOCRATESCASTILLOPE#52590ANENGINEER
LICENSEDPURSUANTTOCHAPTER471,CERTIFYLICENSEDPURSUANTTOCHAPTER471,CERTIFY
SHEET SIZE
THATTHEINSTALLATIONOFTHEMODULESISINTHATTHEPVELECTRICALSYSTEMAND
ANSI B
COMPLIANCEWITHFBC:RESIDENTIAL2020,ELECTRICALCOMPONENTSAREDESIGNEDAND
CHAPTER3.BUILDINGSTRUCTUREWILLSAFELYAPPROVED USING THE STANDARDS CONTAINED IN
11" X 17"
ACCOMMODATEWINDLATERALANDUPLIFTTHEMOSTRECENTVERSIONOFTHEFLORIDA
FORCES, AND EQUIPMENT DEAD LOADS.BUILDING CODE. FBC 107.
SHEET NUMBER
G-01
{ǤƭƷĻƒ 5ĻƭĭƩźƦƷźƚƓ
Symbols:Abbreviations:
Thissystemisagrid-tied,PVsystem,withPVgenerationconsistingof
AC Alternating Current
Sheet where
CASTILLO ENGINEERING
section is located
SERVICES, LLC
X
combinedSTCrateddcoutput
20x370SILFAB:SIL-370BK(370W)Moduleswitha
Section..............
COA # 28345
X-XX
ACD AC Disconnect
620 N. WYMORE ROAD,
powerofW.Themodulesareconnectedinto
7,40020Enphase:IQ7PLUS-72-2-US
SUITE 250,
MAITLAND, FL 32751
Detail ID Letter Theinverterhaselectronicmaximumpowerpointtrackingto
microinverters.
APPROX Approximate
TEL: (407) 289-2575
X
ERMOCRATES E. CASTILLO - FL PE 52590
Elevation ...........
Sheet where
maximizeenergycapturedbythePVmodules.Theinverteralsohasaninternal
X-XX
section is located
AWG American Wire Gauge COPYRIGHTED BY
groundfaultdetectionandinterruptiondevicethatissettodisconnectthearrayin
CASTILLO ENGINEERING
Detail ID Letter
SERVICES, LLC
theeventthatagroundfaultthatexceedsoneampereshouldoccur.Theinverter
BAT
Battery
X
Detail ................
REVISIONS
Sheet where
X-XX
hasDCandACdisconnectintegratedsystemandlabelsareprovidedasrequiredby
section is located
CB Combiner Box
DESCRIPTIONDATEREV
the bğƷźƚƓğƌ 9ƌĻĭƷƩźĭğƌ /ƚķĻ
Detail ID Letter
Detail ................
DC Direct Current
X
Area to be enlarged
(Enlarged Plan)
X-XX
Whenthesunisshining,powerfromthePVarrayisfedintotheinverter,
DISC Disconnect
Sheet where
whereitisconvertedfromDCtoAC.Theinverteroutputisthenusedto
section is located
(E) Existing
contributetothepowerrequirementsoftheoccupancy.IfPVpowermeetsthe
PROJECT INSTALLER
Keyed Notes ..........
1
Keyed note designation
requirementsoftheloadsoftheoccupancy,anyremainingPVpowerissoldback
on applicable sheet
EL Elevation
totheutility.Whenutilitypowerisavailable,butPVpowerisnotavailable,
EQ Equal
building loads are supplied by the utility.
Ground Terminal .....
GP
Generation Panel
PV Modules
Grounding Point/rod....
JB Junction Box
Ejhjubmmz
Microinverters Signature with Seal
tjhofe!cz;
Junction
Point of
Fsnpdsbuft
MCB Main Combiner Box
Box
Utility
F!Dbtujmmp
Solar Panel ......... or
00
Module with Source
Ebuf;
Connection
MFR Manufacturer
Circuit number
3132/18/18
24;59;42
Utility Meter
Figure 1: PV System Block Diagram
MID Microgrid Interconnect Device
Combiner Box ..........
CB
MIN Minimum
PROJECT NAME
The inverter meets the requirements of IEEE 1547 and UL 1741.
MISC Miscellaneous
AC Disconnect ..........
ACD
Main Distribution Panel
MDP
Main Distribution
(N) New
MDP
Panel ......................
FALL PROTECTION:
NAVD North American Vertical datum
ANCHORAGES USED FOR ATTACHMENT OF PERSONAL FALL ARREST EQUIPMENT
Fuse ......................
MUSTBEINDEPENDENTOFANYANCHORAGEBEINGUSEDTOSUPPORTOR
OCPD OverCurrent Protection Device
SUSPENDPLATFORMS,ANDCAPABLEOFSUPPORTINGATLEAST5,000POUNDS
PER EMPLOYEE ATTACHED, OR MUST BE DESIGNED AND USED AS FOLLOWS:
POCC Point Of Common Coupling
Overcurrent Breaker ..
AS PART OF A COMPLETE PERSONAL FALL ARREST SYSTEM WHICH
PV Photovoltaic MAINTAINS A SAFETY FACTOR OF AT LEAST TWO.
UNDER THE SUPERVISION OF A QUALIFIED PERSON
Inverter ....................
SF Squarefoot/feet
ADDITIONAL INFORMATION
STC Standard Test Conditions
29 CFR 1926 SUBPART M, FALL PROTECTION. OSHA STANDARD.
Transformer .............
1926.502, FALL PROTECTION SYSTEMS CRITERIA AND PRACTICES
Soladeck
SD
1926.502(D)(15)
Automatic ...............
SHEET NAME
TBD To Be Determined
ATS
39.98"
Transfer Switch
NOTES AND
TYP Typical
DESCRIPTION
Vent, Attic fan
ALLOWABLE/DESIGN PRESSUREPSF
(Roof obstruction)
UNO
Unless Noted Otherwise
DOWN PRESSURE79.3
SHEET SIZE
PV Roof Attachment
RAILS IN THIS
Utility meter UPLIFT PRESSURE, 2 RAILS
79.3
UM
POSITION UNO
ANSI B
Trusses
11" X 17"
Conduit
VIF Verify In Field
Fire Access
SHEET NUMBER
SILFAB: SIL-370 BK
WP Weather Proof
(370W) MODULES
A-00
CASTILLO ENGINEERING
SERVICES, LLC
COA # 28345
620 N. WYMORE ROAD,
SUITE 250,
MAITLAND, FL 32751
TEL: (407) 289-2575
ERMOCRATES E. CASTILLO - FL PE 52590
COPYRIGHTED BY
CASTILLO ENGINEERING
SERVICES, LLC
REVISIONS
(E) UTILITY METER
DESCRIPTIONDATEREV
(E) MAIN DISTRIBUTION PANEL
(N) TESLA BACKUP GATEWAY 2
(N) (01) TESLA POWERWALL 2
(N) AC DISCONNECT (IF REQUIRED)
(N) PRODUCTION METER (IF REQUIRED)
PROJECT INSTALLER
(N) ENPHASE IQ COMBINER BOX
FIRE ACCESS AND PATHWAYS
Ejhjubmmz
AS PER NFPA 11.12.2
Signature with Seal
tjhofe!cz;
Fsnpdsbuft
F!Dbtujmmp
Ebuf;
3132/18/18
24;59;42
PROJECT NAME
3/4" IMC, RMC, FMC, LFMC, PVC,
HDPE, NUCC, RTRC, LFNC, FMT,
ENT OR EMT CONDUIT RUN
(N) SOLADECK
ROOF #1
(20) SILFAB: SIL-370 BK (370W)
MODULES
(N) (20) ENPHASE: IQ7PLUS-72-2-US
MICROINVERTERS
SHEET NAME
ROOF PLAN
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
SCALE: 1/16" = 1'-0"
A-01
A-01
MODULE TYPE, DIMENSIONS & WEIGHT
ARRAY AREA & ROOF AREA CALC'S
GENERAL INSTALLATION PLAN NOTES:
ROOF
NUMBER OF MODULES = 20 MODULES
ARRAYROOFAREA
1)ROOFATTACHMENTSTOSYPTRUSSESSHALLBEINSTALLEDAS
MODULE TYPE =
SILFAB: SIL-370 BK (370W) MODULES
TRUSSTRUSS
AREAAREACOVERED
ROOFROOF TYPETILTAZIMUTH
SHOWN IN SHEET S-02 AND AS FOLLOWS FOR EACH WIND ZONE:
MODULE WEIGHT = 41.89 LBS / 19.0 KG.
SIZESPACING
CASTILLO ENGINEERING
(sq.Ft.)BY ARRAY
(Sq. Ft.)
MODULE DIMENSIONS = 70.67" x 39.98" = 19.62 SF
SERVICES, LLC
(%)
UNIT WEIGHT OF ARRAY = 2.13 PSF
COA # 28345
NON - EXPOSED MODULESEDGE / EXPOSED MODULES
620 N. WYMORE ROAD,
#1ASPHALT SHINGLE392.411127.6934.8026.62"X4"24" O.C.
SUITE 250,
WIND
MAITLAND, FL 32751
ZONES
TEL: (407) 289-2575
ERMOCRATES E. CASTILLO - FL PE 52590
SPANCANTILEVERSPANCANTILEVER
COPYRIGHTED BY
CASTILLO ENGINEERING
ZONE 14' - 0"1' - 4"2' - 0"0' - 8"
SERVICES, LLC
ZONE 1'XXXX
REVISIONS
2' - 0"0' - 8"2' - 0"
ZONE 2eX
DESCRIPTIONDATEREV
ZONE 2nXXX1' - 4"
ZONE 2r2' - 0"0' - 8"2' - 0"0' - 8"
ZONE 3e2' - 0"0' - 8"2' - 0"0' - 8"
ZONE 3rXXXX
PROJECT INSTALLER
SEE SHEET S-02.1 FOR SUPPORTING CALCULATIONS.
2) EXISTING RESIDENTIAL BUILDING IS AN ASPHALT SHINGLE ROOF
WITHMEANROOFHEIGHTIS15FTANDSYP2"X4"ROOFTRUSSES
SPACED24"O.C.EXISTINGROOFSLOPEFORSOLARSYSTEM
RETROFITIS26.6DEGREES.CONTRACTORTOFIELDVERIFYAND
SHALLREPORTTOTHEENGINEERIFANYDISCREPANCIES
Ejhjubmmz
EXIST BETWEEN PLANS AND IN FIELD CONDITIONS.
Signature with Seal
tjhofe!cz;
Fsnpdsbuft
3) FIRE SETBACK TO BE 3' FROM RIDGES AND EDGES, AND 18"EACH
F!Dbtujmmp
WAY FROM HIPS AND VALLEYS PER NFPA 11.12.2
Ebuf;
3132/18/18
*ICERTIFYTHATTHEINSTALLATIONOFTHEMODULESISIN
24;59;43
COMPLIANCEWITHFBC:RESIDENTIALCHAPTER3.BUILDING
STRUCTUREWILLSAFELYACCOMMODATELATERALANDUPLIFT
WIND LOADS AND EQUIPMENT DEAD LOADS. *
PROJECT NAME
MODULE FRAME
DYNORAXX DYNOBOND
SEE SPEC. SHEET/DS-08
ROOF #1
(20) SILFAB: SIL-370 BK (370W)
MODULES
(N) (20) ENPHASE: IQ7PLUS-72-2-US
MICROINVERTERS
(N) QRAIL LIGHT (TYP.)
(44) PV ROOF ATTACHMENT
@ 24" & 48" O.C. MAX.
PV MODULE
(SEE SHEET S-02 FOR
ATTACHMENT DETAIL)
LEGEND
(SEE SHEET S-01.1 FOR PARTIAL
PRESSURE OF THE MODULE)
- WIND ZONE 1 (TYP)
SHEET NAME
- WIND ZONE 2e (TYP)
-
WIND ZONE 2n (TYP)
SHEET SIZE
- WIND ZONE 2r (TYP)
ANSI B
11" X 17"
-
WIND ZONE 3r (TYP)
SHEET NUMBER
- WIND ZONE 3e (TYP)
S-01SCALE: 3/32" = 1'-0"
S-01
FOR EXPOSED MODULES
CASTILLO ENGINEERING
SERVICES, LLC
COA # 28345
620 N. WYMORE ROAD,
SUITE 250,
MAITLAND, FL 32751
TEL: (407) 289-2575
ERMOCRATES E. CASTILLO - FL PE 52590
COPYRIGHTED BY
CASTILLO ENGINEERING
FOR NON-EXPOSED MODULES
SERVICES, LLC
REVISIONS
DESCRIPTIONDATEREV
PROJECT INSTALLER
ALLOWABLE MODULE UPLIFT PRESSURE 2 RAILS : 79.3 PSF
Ejhjubmmz
Signature with Seal
tjhofe!cz;
Fsnpdsbuft
F!Dbtujmmp
Ebuf;
3132/18/18
24;59;43
PROJECT NAME
2h
2
0.5h
ROOF #1
LEGEND
(20) SILFAB: SIL-370 BK (370W)
MODULES
-
EXPOSED MODULE
- EDGE MODULE
- NON- EXPOSED MODULE
- MISSING MODULE
- MIN. MODULE EDGE DISTANCE LINE
- MODULE EXPOSURE LINE
-
WIND ZONE 1 (TYP)
SHEET NAME
-
2hDISTANCE : 0' - 10"WIND ZONE 2e (TYP)
2
0.5hDISTANCE : 7' - 6"
- WIND ZONE 2n (TYP)
NOTE:PARTIALPRESSURESOFTHEWINDZONESON
SHEET SIZE
ALLMODULESHAVEBEENVERIFIEDANDAREWITHIN
-
WIND ZONE 2r (TYP)
ANSI B
THEALLOWABLEPERTHEMANUFACTURER
SPECIFICATION,INSTALLERSHOULDFOLLOWTHE
11" X 17"
- WIND ZONE 3r (TYP)
LAYOUTTOAVOIDHIGHERZONALPARTIAL
SHEET NUMBER
PRESSURES.ANYCHANGESINLAYOUTSHOULDBE
-
WIND ZONE 3e (TYP)
REPORTEDBACKTOTHEENGINEEROFRECORD.
S-01.1SCALE: 1/8" = 1'-0"
S-01.1
h
(E) ASPHALT SHINGLE
CASTILLO ENGINEERING
ROOF
GROUNDING END CLAMP
SERVICES, LLC
COA # 28345
620 N. WYMORE ROAD,
SUITE 250,
MAITLAND, FL 32751
SOLAR MODULE
TEL: (407) 289-2575
ERMOCRATES E. CASTILLO - FL PE 52590
COPYRIGHTED BY
CASTILLO ENGINEERING
SEE (2/S-02) FOR
SERVICES, LLC
ENLARGED VIEW
REVISIONS
DESCRIPTIONDATEREV
DYNOBOND JUMPER
TRUSSES
(E)2"X4" @ 24" O.C.
PROJECT INSTALLER
S-02SCALE: 1'' = 1' - 0''
HIDDEN END CLAMP AND SKIRT
Ejhjubmmz
(OPTIONAL)
Signature with Seal
tjhofe!cz;
Fsnpdsbuft
F!Dbtujmmp
Ebuf;
GROUNDING MID CLAMP 3132/18/18
(N) CAP SCREW, HEX
24;59;44
HEAD, 5/16-18X1"
UNC-2A,18-8 SS
PROJECT NAME
QUICK MOUNT L FOOT
QUICKMOUNT QMLM
B FLASHING
2"X4" TRUSS SPANNER FOR
MISSED TRUSS ATTACHMENT
(IF REQUIRED)
QRAIL LIGHT (TYP)
SHEET NAME
SHEET SIZE
5/16"DIA. X 2.5"MIN.
EMBEDMENT LAG SCREW
(E) 2"X4"TRUSSES @ 24" O.C.
ANSI B
AT EACH ATTACHMENT POINT
11" X 17"
INTO EXISTING FRAMING
SHEET NUMBER
S-02
S-02
SCALE: 1"=2"
CASTILLO ENGINEERING
SERVICES, LLC
COA # 28345
620 N. WYMORE ROAD,
SUITE 250,
MAITLAND, FL 32751
TEL: (407) 289-2575
ERMOCRATES E. CASTILLO - FL PE 52590
COPYRIGHTED BY
CASTILLO ENGINEERING
SERVICES, LLC
REVISIONS
DESCRIPTIONDATEREV
PROJECT INSTALLER
Ejhjubmmz
Signature with Seal
tjhofe!cz;
Fsnpdsbuft
F!Dbtujmmp
Ebuf;
3132/18/18
24;59;44
PROJECT NAME
SHEET NAME
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
S-02.1
SOLAR ARRAY (7.400 kW-DC STC)
(20) SILFAB: SIL-370 BK (370W) MODULES
(02) BRANCH OF 10 MODULES
CASTILLO ENGINEERING
NOTE:
SERVICES, LLC
1.SUBJECTPVSYSTEMSHASBEENDESIGNEDTOMEETTHE
COA # 28345
REQUIREMENTSOFTHENEC2017,ANDTHOSESETFORTHBYTHE
620 N. WYMORE ROAD,
FLORIDASOLARENERGYCENTERCERTIFICATION,INCLUDING
SUITE 250,
MAITLAND, FL 32751
MAXIMUMNUMBEROFMODULESTRINGS,MAXIMUMNUMBEROF
TEL: (407) 289-2575
MODULESPERSTRING,MAXIMUMOUTPUT,MODULE
ERMOCRATES E. CASTILLO - FL PE 52590
Q CABLE
MANUFACTURERANDMODELNUMBER,INVERTERMANUFACTURER
COPYRIGHTED BY
AND MODEL NUMBER, AS APPLICABLE.
CASTILLO ENGINEERING
SERVICES, LLC
ENPHASE: IQ7PLUS-72-2-US
REVISIONS
MICROINVERTERS
DESCRIPTIONDATEREV
PV MODULES
PROJECT INSTALLER
INTERCONNECTION
120% RULE - CEC 705.12(B)(2)(3)(b)
UTILITY FEED + SOLAR BACKFEED
200A + 40A = 240A
BUSS RATING x 120%
200A x 120% = 240A
(N) SOLADECK
600 V, NEMA 3R
UL LISTED
Ejhjubmmz
Signature with Seal
tjhofe!cz;
Fsnpdsbuft
F!Dbtujmmp
Ebuf;
3132/18/18
TO UTILITY GRID
24;59;45
(3) 10/2 ROMEX RUN IN ATTIC
(N) AC DISCONNECT:
L1L2N
OR
240V, 60AMP RATED,
(3) #10 AWG THWN-2 - RED
(N) 125A ENPHASE IQ COMBINER 3
NEMA 3R, UL LISTED
BI-DIRECTIONAL
(3) #10 AWG THWN-2 - BLACK
(N) PV METERPROJECT NAME
(X-IQ-AM1-240-3) \[WITH UPTO (4)
LOCKABLE & NON-FUSED
UTILITY METER
EGC #8 AWG THWN-2
(IF REQUIRED)
2-POLE BREAKERS AND ENVOY
(IF REQUIRED)
1-PHASE, 240V
IN 3/4" PVC, IMC, RMC, FMC,
COMMUNICATION GATEWAY\]
LFMC, HDPE, NUCC, RTRC,
L1L2N
LFNC, EMT, FMT OR ENT
L1L1L1
L1L1
(E) MAIN DISTRIBUTION
CONDUIT RUN
L2
PANEL, 200A RATED, 240V
L2L2
L2L2
NNN
NN
GGG
GG
(E) MAIN BREAKER
10A
200A/2P, 240V
(3) #8AWG THWN-2
(1) #10 AWG THWN-2 GND
L1L1
IN 3/4" PVC, IMC, RMC, FMC,
L2L2
LFMC, HDPE, NUCC, RTRC,
LFNC, EMT, FMT, ENT
L1L1
CONDUIT RUN
20A/2P
L2L2
L1
40A/2P
L2
L1L1
20A/2P
L1
L2L2
L2
SHEET NAME
N
ELECTRICAL
G
LINE DIAGRAM
NG
G
EXISTING GROUNDING
ELECTRODE SYSTEM
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
SCALE: NTS
E-01
E-01
SOLAR ARRAY (7.400 kW-DC STC)
(20) SILFAB: SIL-370 BK (370W) MODULES
(02) BRANCH OF 10 MODULES
CASTILLO ENGINEERING
NOTE:
SERVICES, LLC
1.SUBJECTPVSYSTEMSHASBEENDESIGNEDTOMEETTHE
COA # 28345
REQUIREMENTSOFTHENEC2017,ANDTHOSESETFORTHBYTHE
620 N. WYMORE ROAD,
FLORIDASOLARENERGYCENTERCERTIFICATION,INCLUDING
SUITE 250,
MAITLAND, FL 32751
MAXIMUMNUMBEROFMODULESTRINGS,MAXIMUMNUMBEROF
TEL: (407) 289-2575
MODULESPERSTRING,MAXIMUMOUTPUT,MODULE
ERMOCRATES E. CASTILLO - FL PE 52590
Q CABLE
MANUFACTURERANDMODELNUMBER,INVERTERMANUFACTURER
COPYRIGHTED BY
AND MODEL NUMBER, AS APPLICABLE.
CASTILLO ENGINEERING
2.PROVIDETAPBOXINCOMPLIANCEWITHNEC312.8IFPANEL
SERVICES, LLC
GUTTER SPACE IS INADEQUATE.
ENPHASE: IQ7PLUS-72-2-US
3.IFTHEFUSEDACDISCONNECTWIRERUNEXCEEDS10FTFROM
REVISIONS
MICROINVERTERS
THEPOINTOFINTERCONNECTION,CABLELIMITERSOR
DESCRIPTIONDATEREV
CURRENT-LIMITEDCIRCUITBREAKERSMUSTBEINSTALLEDFOR
PV MODULES
EACH UNGROUNDED CONDUCTOR PER NEC 705.31.
(2) #1/0 AWG THWN-2
(1) #1/0 AWG THWN-2 NTL
PROJECT INSTALLER
IN 3/4" IMC, RMC, FMC, LFMC,
PVC, HDPE, NUCC, RTRC,
LFNC, FMT, ENT, OR EMT
(N) 200A TESLA BACKUP GATEWAY 2
CONDUIT RUN
AUTOMATIC TRANSFER SWITCH
MICROGRID INTERCONNECT DEVICE
UL LISTED, SER RATED
TO UTILITY GRID
(N) SOLADECK
(N) (1) TESLA POWERWALL 2
LINE TAP USING INSULATION
600 V, NEMA 3R
BATTERIES
PIERCING PER NEC 705.12(A)
UL LISTED
Ejhjubmmz
L1L2N
5KW CONTINUOUS POWER
L1L2N
Signature with Seal
13.5KWH STORAGE
tjhofe!cz;
Fsnpdsbuft
(N) MAIN
BI-DIRECTIONAL
SERVICE
F!Dbtujmmp
UTILITY METER
GNL2L1
DISCONNECT
Ebuf;
1-PHASE, 240V
30A/2P 200A/2P, 240V
3132/18/18
L1
(E) MAIN DISTRIBUTION
24;59;45
L2 L1L2N
(3) 10/2 ROMEX RUN IN ATTIC
PANEL, 200A RATED,
40A/2P
OR
240V.
L1
(3) #10 AWG THWN-2 - RED
(N) 125A ENPHASE IQ COMBINER 3
L2
(3) #10 AWG THWN
(3) #10 AWG THWN-2 - BLACK
PROJECT NAME
(X-IQ-AM1-240-3) \[WITH UPTO (4)
(1) #10 AWG THWN-2 GND
EGC #8 AWG THWN-2
N
2-POLE BREAKERS AND ENVOY IN 3/4" IMC, RMC, FMC, LFMC,
(E) MAIN BREAKER
IN 3/4" PVC, IMC, RMC, FMC,
PVC, HDPE, NUCC, RTRC,
G
COMMUNICATION GATEWAY\]
L1L1L2L2
200A/2P, 240V
LFMC, HDPE, NUCC, RTRC,
LFNC, FMT, ENT, OR EMT
LFNC, EMT, FMT OR ENT
CONDUIT RUN
L1
N
CONDUIT RUN
L2
G
N
G
L1L1
10A
L2L2
L1L2NG
L1L1
L2L2
(N) AC DISCONNECT:
150A/2P
L1L1
240V, 60AMP RATED,
NEMA 3R, UL LISTED
L2L2
(N) PV METER
LOCKABLE & NON-FUSED
L1L1
(IF REQUIRED)
(IF REQUIRED)
L2L2
20A/2P
N
L1
L1L1
L1L1
L1L1
L2
G
L2L2
20A/2P
L2L2
L2L2
L1
EXISTING GROUNDING
NN
NN
N
L2
ELECTRODE SYSTEM
SHEET NAME
G
GG
GG
(N) 150A BACKUP PANEL
(2) #1/0 AWG THWN-2
ELECTRICAL
120/240VAC
(1) #1/0 AWG THWN-2 NTL
LINE DIAGRAM
(1) #6 AWG THWN-2 GND
NG
G
IN 3/4" IMC, RMC, FMC, LFMC,
PVC, HDPE, NUCC, RTRC,
(3) #8 AWG THWN-2
SHEET SIZE
LFNC, FMT, ENT, OR EMT
(1) #10 AWG THWN-2 GND
CONDUIT RUN
IN 3/4" PVC, IMC, RMC, FMC,
ANSI B
LFMC, HDPE, NUCC, RTRC,
11" X 17"
LFNC, EMT, FMT, ENT
CONDUIT RUN
SHEET NUMBER
SCALE: NTS
E-01.1
E-01.1
ELECTRICAL CALCULATION
ELECTRICAL NOTES
1.ALLEQUIPMENTTOBELISTEDBYULOROTHERNRTL,ANDLABELED
FOR ITS APPLICATION.
CASTILLO ENGINEERING
SERVICES, LLC
2.ALLCONDUCTORSSHALLBECOPPER,RATEDFOR600VAND90
COA # 28345
DEGREECWETENVIRONMENT.THETERMINALSARERATEDFOR75
620 N. WYMORE ROAD,
SUITE 250,
DEGREE C.
MAITLAND, FL 32751
TEL: (407) 289-2575
3.THE WIRES ARE SIZED ACCORDING TO NEC 110.14.
ERMOCRATES E. CASTILLO - FL PE 52590
4.WIRING,CONDUIT,ANDRACEWAYSMOUNTEDONROOFTOPSSHALL
COPYRIGHTED BY
BEROUTEDDIRECTLYTO,ANDLOCATEDASCLOSEASPOSSIBLETO
CASTILLO ENGINEERING
THE NEAREST RIDGE, HIP, OR VALLEY.
SERVICES, LLC
5.WORKINGCLEARANCESAROUNDALLNEWANDEXISTINGELECTRICAL
REVISIONS
EQUIPMENT SHALL COMPLY WITH NEC 110.26.
DESCRIPTIONDATEREV
6.DRAWINGSINDICATETHEGENERALARRANGEMENTOFSYSTEMS.
CONTRACTORSHALLFURNISHALLNECESSARYOUTLETS,SUPPORTS,
FITTINGSANDACCESSORIESTOFULFILLAPPLICABLECODESAND
STANDARDS.
7.WHERESIZESOFJUNCTIONBOXES,RACEWAYS,ANDCONDUITSARE
NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY.
PROJECT INSTALLER
8.ALLWIRETERMINATIONSSHALLBEAPPROPRIATELYLABELEDAND
READILY VISIBLE.
9.MODULEGROUNDINGCLIPSTOBEINSTALLEDBETWEENMODULE
FRAMEANDMODULESUPPORTRAIL,PERTHEGROUNDINGCLIP
MANUFACTURER'S INSTRUCTION.
10.MODULESUPPORTRAILTOBEBONDEDTOCONTINUOUSCOPPER
G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG.
Ejhjubmmz
Signature with Seal
11.THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE .
tjhofe!cz;
12.UTILITYHAS24-HRUNRESTRICTEDACCESSTOALL
Fsnpdsbuft
PHOTOVOLTAICSYSTEMCOMPONENTSLOCATEDATTHESERVICE
F!Dbtujmmp
Ebuf;
ENTRANCE.
3132/18/18
13.MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.
24;59;46
14.RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.
15.CONDUCTORSEXPOSEDTOSUNLIGHTSHALLBELISTEDASSUNLIGHT
RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.10 (D).
PROJECT NAME
16.CONDUCTORSEXPOSEDTOWETLOCATIONSSHALLBESUITABLEFOR
USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C).
17.THISSYSTEMISEQUIPPEDWITHRAPIDSHUTDOWNOFPV
CONDUCTORS IN COMPLIANCE WITH NEC 690.12.
18.LABELINGINCOMPLIANCEWITHNEC690.12AND690.56(C)ISSHOWN
ON SHEET E-03.
IERMOCRATESCASTILLOPE#52590ANENGINEER
LICENSEDPURSUANTTOCHAPTER471,CERTIFY
THATTHEPVELECTRICALSYSTEMANDELECTRICAL
SHEET NAME
COMPONENTSAREDESIGNEDANDAPPROVEDUSING
THESTANDARDSCONTAINEDINTHEMOSTRECENT
VERSION OF THE FLORIDA BUILDING CODE. FBC 107.
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
E-02
PHOTOVOLTAIC SYSTEM AC DISCONNECT
!
WARNING
RATED ACOPERATING CURRENT 24.2 AMPS
SOLAR PV SYSTEM EQUIPPED
ELECTRIC SHOCK HAZARD
CASTILLO ENGINEERING
AC NOMINAL OPERATING VOLTAGE 240 VOLTS
TERMINALS ON BOTH LINE AND
SERVICES, LLC
WITH RAPID SHUTDOWN
LOAD SIDES MAY BE ENERGIZED
COA # 28345
620 N. WYMORE ROAD,
LABEL LOCATION:
IN THE OPEN POSITION
SUITE 250,
AC DISCONNECT, POINT OF INTERCONNECTION
MAITLAND, FL 32751
(PER CODE: NEC 690.54)
LABEL LOCATION:TEL: (407) 289-2575
ERMOCRATES E. CASTILLO - FL PE 52590
AC DISCONNECT, POINT OF INTERCONNECTION
(PER CODE: NEC 690.13(B))
COPYRIGHTED BY
WARNING
TURN RAPID SHUTDOWN
CASTILLO ENGINEERING
INVERTER OUTPUT CONNECTION DO NOT
SWITCH TO THE
SERVICES, LLC
SOLAR ELECTRIC
PV PANELS
"OFF" POSITION TO
!
RELOCATE THIS OVERCURRENT DEVICE REVISIONS
DESCRIPTIONDATEREV
LABEL LOCATION:
SHUT DOWN PV SYSTEM
POINT OF INTERCONNECTION
PER AHJ 7/1/2021 A
LABEL LOCATION:
AND REDUCE
(PER CODE: NEC 705.12(B)(2)(3)(b))
POINT OF INTERCONNECTION
SHOCK HAZARD
(PER CODE: NEC 705.12(B)(2)(3)(b))
IN THE ARRAY
DATA PER PANEL
PROJECT INSTALLER
RAPID SHUTDOWN
NOMINAL OPERATING AC VOLTAGE -
V
240
LABEL LOCATION:
SWITCH FOR
AC DISCONNECT, POINT OF INTERCONNECTION
(PER CODE: NEC 690.56(C)(1)(a), IFC 605.11.3.1(1)
NOMINAL OPERATING AC FREQUENCY-
Hz
60
SOLAR PV SYSTEM
MAXIMUM AC POWER-
VA
290
LABEL LOCATION:
AC DISCONNECT
MAXIMUM AC CURRENT-
A
1.21
(PER CODE: NEC 690.56(C)(3))
EMERGENCY RESPONDER:EMERGENCY RESPONDER:
Ejhjubmmz
Signature with Seal
MAXIMUM OVERCURRENT DEVICE RATING
tjhofe!cz;
A
ADHESIVE FASTENED SIGNS:
20
THIS SOLAR PV SYSTEM IS EQUIPPEDTHIS SOLAR PV SYSTEM IS EQUIPPED
FOR AC MODULE PROTECTION PER CIRCUIT-
THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT Fsnpdsbuft
WHERE IT IS INSTALLED.
F!Dbtujmmp
WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD
WITH RAPID SHUTDOWN.WITH RAPID SHUTDOWN.
Ebuf;
APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD
3132/18/18
COMPLY WITH ANSI Z535.4 \[NEC 110.21(B) FIELD MARKING\].
LABEL LOCATION:
24;59;47
ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF
COMBINER BOX
PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER
TURN RAPID SHUTDOWN SWITCH TO THE ''OFF''TURN RAPID SHUTDOWN SWITCH TO THE ''OFF''
(PER CODE: NEC 690.52)
RESISTANT \[IFC 605.11.1.3\]
POSITION TO SHUTDOWN ENTIRE PV SYSTEMPOSITION TO SHUTDOWN ENTIRE PV SYSTEM
PROJECT NAME
NOTES:
WARNING:
ALL LABELS AND MARKINGS ARE TO BE
REFLECTIVE AND MEET ALL THE
THIS EQUIPMENT FED BY MULTIPLE
REQUIREMENTS OF NFPA 1-11.12
TESLA BACKUP GATEWAY 2
SOURCES. TOTAL RATING OF ALL
TESLA POWERWALL 2
AC DISCONNECT
OVERCURRENT DEVICES, EXCLUDING
PRODUCTION METER
A
UTILITY METER
MAIN SUPPLY OVERCURRENT DEVICE,
ENPHASE IQ COMBINER BOX
MAIN DISTRIBUTION
SHALL NOT EXCEED AMPACITY OF BUSBAR
PANEL
LABEL LOCATION:
POINT OF INTERCONNECTION
(PER CODE: NEC 705.12(B)(2)(3)(c))
WARNING
IN CASE OF EMERGENCY, CONTACT:
PES SOLAR
PH. NO. : (321) 356-0249
PV SOLAR ARRAY
LABEL LOCATION:
SHEET NAME
MAIN DISCONNECT
(PER CODE: NFPA 11.12.2.1.5)
23 SWALLOW DR. BOYNTON BEACH, FL 33436
LABEL LOCATION:
MAIN SERVICE DISCONNECT
SHEET SIZE
(PER CODE : NFPA 1,11.12.2.1)
ANSI B
11" X 17"
SHEET NUMBER
E-03
CASTILLO ENGINEERING
SERVICES, LLC
COA # 28345
620 N. WYMORE ROAD,
SUITE 250,
MAITLAND, FL 32751
TEL: (407) 289-2575
ERMOCRATES E. CASTILLO - FL PE 52590
COPYRIGHTED BY
CASTILLO ENGINEERING
SERVICES, LLC
REVISIONS
DESCRIPTIONDATEREV
PROJECT INSTALLER
Ejhjubmmz
Signature with Seal
tjhofe!cz;
Fsnpdsbuft
F!Dbtujmmp
Ebuf;
3132/18/18
24;59;47
PROJECT NAME
SHEET NAME
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
DS-01
CASTILLO ENGINEERING
SERVICES, LLC
COA # 28345
620 N. WYMORE ROAD,
SUITE 250,
MAITLAND, FL 32751
TEL: (407) 289-2575
ERMOCRATES E. CASTILLO - FL PE 52590
COPYRIGHTED BY
CASTILLO ENGINEERING
SERVICES, LLC
REVISIONS
DESCRIPTIONDATEREV
PROJECT INSTALLER
Ejhjubmmz
Signature with Seal
tjhofe!cz;
Fsnpdsbuft
F!Dbtujmmp
Ebuf;
3132/18/18
24;59;48
PROJECT NAME
SHEET NAME
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
DS-01.1
CASTILLO ENGINEERING
SERVICES, LLC
COA # 28345
620 N. WYMORE ROAD,
SUITE 250,
MAITLAND, FL 32751
TEL: (407) 289-2575
ERMOCRATES E. CASTILLO - FL PE 52590
COPYRIGHTED BY
CASTILLO ENGINEERING
SERVICES, LLC
REVISIONS
DESCRIPTIONDATEREV
PROJECT INSTALLER
Ejhjubmmz
Signature with Seal
tjhofe!cz;
Fsnpdsbuft
F!Dbtujmmp
Ebuf;
3132/18/18
24;59;49
PROJECT NAME
SHEET NAME
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
DS-02
CASTILLO ENGINEERINGCASTILLO ENGINEERING
SERVICES, LLCSERVICES, LLC
COA # 28345COA # 28345
620 N. WYMORE ROAD,620 N. WYMORE ROAD,
SUITE 250,SUITE 250,
MAITLAND, FL 32751MAITLAND, FL 32751
TEL: (407) 289-2575TEL: (407) 289-2575
ERMOCRATES E. CASTILLO - FL PE 52590ERMOCRATES E. CASTILLO - FL PE 52590
COPYRIGHTED BYCOPYRIGHTED BY
CASTILLO ENGINEERINGCASTILLO ENGINEERING
SERVICES, LLCSERVICES, LLC
REVISIONSREVISIONS
DESCRIPTIONDESCRIPTIONDATEDATEREVREV
PROJECT INSTALLERPROJECT INSTALLER
Ejhjubmmz
Signature with SealSignature with Seal
tjhofe!cz;
Fsnpdsbuft
F!Dbtujmmp
Ebuf;
3132/18/18
24;59;4:
PROJECT NAMEPROJECT NAME
SHEET NAMESHEET NAME
SHEET SIZESHEET SIZE
ANSI BANSI B
11" X 17"11" X 17"
SHEET NUMBERSHEET NUMBER
DS-03DS-03
CASTILLO ENGINEERINGCASTILLO ENGINEERING
SERVICES, LLCSERVICES, LLC
COA # 28345COA # 28345
620 N. WYMORE ROAD,620 N. WYMORE ROAD,
SUITE 250,SUITE 250,
MAITLAND, FL 32751MAITLAND, FL 32751
TEL: (407) 289-2575TEL: (407) 289-2575
ERMOCRATES E. CASTILLO - FL PE 52590ERMOCRATES E. CASTILLO - FL PE 52590
COPYRIGHTED BYCOPYRIGHTED BY
CASTILLO ENGINEERINGCASTILLO ENGINEERING
SERVICES, LLCSERVICES, LLC
REVISIONSREVISIONS
DESCRIPTIONDESCRIPTIONDATEDATEREVREV
PROJECT INSTALLERPROJECT INSTALLER
Ejhjubmmz
Signature with SealSignature with Seal
tjhofe!cz;
Fsnpdsbuft
F!Dbtujmmp
Ebuf;
3132/18/18
24;59;4:
PROJECT NAMEPROJECT NAME
SHEET NAMESHEET NAME
SHEET SIZESHEET SIZE
ANSI BANSI B
11" X 17"11" X 17"
SHEET NUMBERSHEET NUMBER
DS-04DS-04
CASTILLO ENGINEERINGCASTILLO ENGINEERING
SERVICES, LLCSERVICES, LLC
COA # 28345COA # 28345
620 N. WYMORE ROAD,620 N. WYMORE ROAD,
SUITE 250,SUITE 250,
MAITLAND, FL 32751MAITLAND, FL 32751
TEL: (407) 289-2575TEL: (407) 289-2575
ERMOCRATES E. CASTILLO - FL PE 52590ERMOCRATES E. CASTILLO - FL PE 52590
COPYRIGHTED BYCOPYRIGHTED BY
CASTILLO ENGINEERINGCASTILLO ENGINEERING
SERVICES, LLCSERVICES, LLC
REVISIONSREVISIONS
DESCRIPTIONDESCRIPTIONDATEDATEREVREV
PROJECT INSTALLERPROJECT INSTALLER
Ejhjubmmz
Signature with SealSignature with Seal
tjhofe!cz;
Fsnpdsbuft
F!Dbtujmmp
Ebuf;
3132/18/18
24;59;51
PROJECT NAMEPROJECT NAME
SHEET NAMESHEET NAME
SHEET SIZESHEET SIZE
ANSI BANSI B
11" X 17"11" X 17"
SHEET NUMBERSHEET NUMBER
DS-05DS-05
CASTILLO ENGINEERING
SERVICES, LLC
COA # 28345
620 N. WYMORE ROAD,
SUITE 250,
MAITLAND, FL 32751
TEL: (407) 289-2575
ERMOCRATES E. CASTILLO - FL PE 52590
COPYRIGHTED BY
CASTILLO ENGINEERING
SERVICES, LLC
REVISIONS
DESCRIPTIONDATEREV
PROJECT INSTALLER
Ejhjubmmz
Signature with Seal
tjhofe!cz;
Fsnpdsbuft
F!Dbtujmmp
Ebuf;
3132/18/18
24;59;52
PROJECT NAME
SHEET NAME
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
DS-06
CASTILLO ENGINEERING
SERVICES, LLC
COA # 28345
620 N. WYMORE ROAD,
SUITE 250,
MAITLAND, FL 32751
TEL: (407) 289-2575
ERMOCRATES E. CASTILLO - FL PE 52590
COPYRIGHTED BY
CASTILLO ENGINEERING
SERVICES, LLC
REVISIONS
DESCRIPTIONDATEREV
PROJECT INSTALLER
Ejhjubmmz
Signature with Seal
tjhofe!cz;
Fsnpdsbuft
F!Dbtujmmp
Ebuf;
3132/18/18
24;59;53
PROJECT NAME
SHEET NAME
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
DS-07
CASTILLO ENGINEERING
SERVICES, LLC
COA # 28345
620 N. WYMORE ROAD,
SUITE 250,
MAITLAND, FL 32751
TEL: (407) 289-2575
ERMOCRATES E. CASTILLO - FL PE 52590
COPYRIGHTED BY
CASTILLO ENGINEERING
SERVICES, LLC
REVISIONS
DESCRIPTIONDATEREV
PROJECT INSTALLER
Ejhjubmmz
Signature with Seal
tjhofe!cz;
Fsnpdsbuft
F!Dbtujmmp
Ebuf;
3132/18/18
24;59;53
PROJECT NAME
SHEET NAME
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
DS-08