Loading...
PERMIT DOCUMENTS MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 www.miamidade.gov/economy NOTICE OF ACCEPTANCE (NOA) Boral Roofing, LLC 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 S COPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (in Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. D ESCRIPTION: Boral Villa 900 Concrete Roof Tile L ABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. R ENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. T ERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. A DVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. I NSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. ThisNOA revises NOA No.16-0711.04 and consists of pages 1 through 7. The submitted documentation was reviewed by Freddy Semino NOA No.: 18-0509.16 Expiration Date: 09/21/21 Approval Date: 06/28/18 Page 1 of 7 R OOFING A SSEMBLY A PPROVAL Roofing Category: Roofing Tiles Sub Category: Concrete Material: 1.S COPE This renews a system using Boral Villa 900 Concrete Roof Tile, as manufactured Boral Roofing, LLC in Lake Wales, FL and described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2.P RODUCT D ESCRIPTION Manufactured by Test Product Applicant Dimensions Specifications Description Length = 17" TAS 112 Low profile, interlocking, high pressure extruded Boral Roofing Villa 900 Width = 13" Type 1b concrete roof tile equipped with three nail holes ½" thick Class III and double rolls. For direct deck, batten, mortar or adhesive set applications. Trim Pieces l = varies TAS 112 Accessory trim, concrete roof pieces for use at w = varies ridges, hips and rakes. varying thickness 2.1 P RODUCTS M ANUFACTURED B Y O THERS Product Name Product Description Manufacturer (With Current NOA) ® Two component polyurethane ICP Adhesives and Sealants, Inc. ICP Adhesives Polyset AH-160 foam adhesive. TM TILE BOND Roof Tile Adhesive Single component polyurethane The Dow Chemical Company foam roof tile adhesive. Premixed, pre-bagged roof tile Bermuda Roof Co. Inc. mortar. DAP Foam Touch N Seal Two component polyurethane The Dow Chemical Company ® foam adhesive. StormBond2 Roof Tile Adhesive 2.2 M ANUFACTURING L OCATION Lake Wales, FL 2.2.1. NOA No.: 18-0509.16 Expiration Date: 09/21/21 Approval Date: 06/28/18 Page 2 of 7 2.3 E VIDENCE S UBMITTED Test Agency Test Identifier Test Name/Report Date Nutting Engineers 13343.1 TAS 112 Apr. 2006 Redland Technologies 7161-03 Static Uplift Testing Dec. 1991 Appendix III TAS 102 & TAS 102(A) Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991 Appendix II TAS 108 (Nail-On) Redland Technologies P0402 Withdrawal Resistance Testing of Sept. 1993 screw vs. smooth shank nails The Center for Applied 94-060B Static Uplift Testing March, 1994 Engineering, Inc. TAS 101 (Adhesive Set) The Center for Applied 94-084 Static Uplift Testing May 1994 Engineering, Inc. TAS 101 (Mortar Set) Redland Technologies P0631-01 Wind Tunnel Testing July 1994 TAS 108 (Mortar Set) Redland Technologies Letter Dated Aug. 1, 1994 Wind Tunnel Testing Aug. 1994 TAS 108 (Nail-On) The Center for Applied Project No. 307025 Wind Driven Rain Oct. 1994 Engineering, Inc. Test #MDC-76 TAS 100 The Center for Applied 25-7183-1 Static Uplift Testing Feb. 1995 Engineering, Inc. 25-7183-2 TAS 102 (2 Quik-Drive Screws, Direct Deck) The Center for Applied 25-7214-2 Static Uplift Testing March, 1995 Engineering, Inc. 25-7214-6 TAS 102 (1 Quik-Drive Screw, Direct Deck) (1 Quik-Drive Screw, Battens) Celotex Corporation 528454-2-1 Static Uplift Testing Sep. 1998 Testing Services 520109-2 TAS 101 Dec. 1998 Walker Engineering, Inc. Evaluation Calculations 25-7183 March 1995 Walker Engineering, Inc. Evaluation Calculations 25-7094 February 1996 Walker Engineering, Inc. Evaluation Calculations 25-7496 April 1996 Walker Engineering, Inc. Evaluation Calculations 25-7584 December 1996 25-7804b-8 25-7804-4 & 5 25-7848-6 Walker Engineering, Inc. Evaluation Calculations Aerodynamic Multipliers 09/01/16 Walker Engineering, Inc. Evaluation Calculations Two Patty Adhesive Set System April 1999 Walker Engineering, Inc. Evaluation Calculations Restoring Moment Due to Gravity 09/01/16 American Test Lab of South RT0617.02-16 TAS 112 06/29/16 Florida NOA No.: 18-0509.16 Expiration Date: 09/21/21 Approval Date: 06/28/18 Page 3 of 7 2.3 E VIDENCE S UBMITTED Test Agency Test Identifier Test Name/Report Date PRI Construction Materials COPO-002-02-11 Static Uplift Testing 10/12/2016 Technologies TAS 101 (Adhesive Set) PRI Construction Materials COPO-002-02-04 Static Uplift Testing 10/12/2016 Technologies TAS 101 (Adhesive Set) PRI Construction Materials COPO-002-02-03 Static Uplift Testing 10/12/2016 Technologies TAS 101 (Adhesive Set) 3. L IMITATIONS: Fire classification is not part of this acceptance. 3.1 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 3.2 106. Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test in 3.3 Office for review. Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed 3.4 section 4.1 herein. 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated 3.5 otherwise by the underlayment material manufacturers published literature. This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with 3.6 applicable building code. 4. I NSTALLATION Villa 900 Concrete Roof Tile and its components shall be installed in strict compliance with Roofing 4.1 Application Standard RAS 118, RAS 119, and RAS 120. Data For Attachment Calculations 4.2 Table 1: Average Weight (W) and Dimensions (l x w ) Tile Profile Weight-W (lbf) Length-l (ft) Width-w (ft) Villa 900 Concrete Tile 10.90 1.42 1.08 3 Table 2: Aerodynamic Multipliers - (ft) 33 Tile (ft) (ft) Profile Batten Application Direct Deck Application Villa 900 Concrete Tile 0.291 0.315 Table 3: Restoring Moments due to Gravity - M (ft.-lbf.) g Tile 2":12" 3":12" 4":12" 5":12" 6":12" 7":12" or Profile greater Villa 900 Direct Direct Battens Direct Battens Direct Battens Direct Battens Direct Concrete Tile Deck Deck Deck Deck Deck Deck 7.70 7.62 6.56 7.50 6.42 7.34 6.26 7.15 6.08 6.95 NOA No.: 18-0509.16 Expiration Date: 09/21/21 Approval Date: 06/28/18 Page 4 of 7 Table 4: Attachment Resistance Expressed as a Moment - M (ft-lbf) f for Mechanically Fastened Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (min 15/32" plywood) (min. 19/32" plywood) Villa 900 2-10d Ring Shank Nails 27.8 37.4 28.8 Concrete Tile 1-10d Smooth or Screw 8.8 11.8 4.1 Shank Nail 2-10d Smooth or Screw 16.4 21.9 7.1 Shank Nails 1 #8 Screw 25.8 25.8 22.9 2 #8 Screw 47.1 47.1 49.1 1-10d Smooth or Screw 24.3 24.3 24.2 Shank Nail (Field Clip) 1-10d Smooth or Screw 19.0 19.0 22.1 Shank Nail (Eave Clip) 2-10d Smooth or Screw 35.5 35.5 34.8 Shank Nails (Field Clip) 2-10d Smooth or Screw 31.9 31.9 32.2 Shank Nails (Eave Clip) Table 5: Attachment Resistance Expressed as a Moment M (ft-lbf) f 1 for Two Paddy Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance 2 Villa 900 Concrete Tile The Dow Chemical Company TileBond 26.1 3 26.1 ICP Adhesives PolysetŽ AH-160 two- component foam ® 4 DAP Foam Touch N Seal StormBond 2 Roof 55 Tile Adhesive two-component foam 1 See foam adhesive manufactures component approval for installation requirements. 2 The Dow Chemical Company TileBond one-component foam, minimum weight per paddy 11.4 grams. 3 ICP Adhesives PolysetŽ AH-160 two-component foam, minimum weight per paddy 8 grams. ® 4 DAP Foam Touch N Seal StormBond 2 Roof Tile Adhesive, average weight per paddy 8 grams, two component foam. Table 6: Attachment Resistance Expressed as a Moment - M (ft-lbf) f for Single Paddy Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance 5 ICP Adhesives PolysetŽ AH-160 two-component foam Villa 900 Concrete Tile 86.61 6 ICP Adhesives PolysetŽ AH-160 two-component foam 45.5 ® 7 DAP Foam Touch N Seal StormBond 2 Roof Tile 40 Adhesive ® 8 DAP Foam Touch N Seal StormBond 2 Roof Tile 70 Adhesive NOA No.: 18-0509.16 Expiration Date: 09/21/21 Approval Date: 06/28/18 Page 5 of 7 5 Large paddy placement of minimum 54 grams. 6 Medium paddy placement of minimum 24 grams. 7 Medium paddy placement of minimum 30 grams. 8 Large paddy placement of minimum 60 grams. Table 7: Attachment Resistance Expressed as a Moment - M(ft-lbf) f for Mortar Set Systems Tile Tile Attachment Profile Application Resistance 6 Villa 900 Concrete Tile Mortar Set 20.60 6Tile-Tite Roof Tile Mortar. 5. L ABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed below, or following statement: "Miami-Dade County Product Control Approved". L ABEL FOR B ORAL V ILLA 900 C ONCRETE T ILE (L OCATED ON THE UNDERSIDE OF TILE) 6. B UILDING P ERMIT R EQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 6.1 This Notice of Acceptance. 6.1.1 Any other documents required by Building Official or Applicable building code in order to properly 6.1.2 evaluate the installation of this system. NOA No.: 18-0509.16 Expiration Date: 09/21/21 Approval Date: 06/28/18 Page 6 of 7 P ROFILE D RAWING V ILLA 900 C ONCRETE R OOF T ILE END OF THIS ACCEPTANCE NOA No.: 18-0509.16 Expiration Date: 09/21/21 Approval Date: 06/28/18 Page 7 of 7 TUSVDUVSF TzmwftusjK!2302503132 TUSVDUVSFTzmwftusjK!2302503132 TUSVDUVSFTzmwftusjK!2302503132 TUSVDUVSFTzmwftusjK!2302503132