PERMIT DOCUMENTS N EMO|etc. CertificateofAuthorization#32455 353ChristianStreet,Unit#13 Oxford,CT06478 (203)262-9245 E NGINEER E VALUATE T EST C ONSULT EVALUATIONREPORT EvaluationReportP40690.12.13-1-R11 PolyglassUSA,Inc. FL16717-R10 1111WestNewportCenterDrive DateofIssuance:12/12/2013 DeerfieldBeach,FL33442 Revision11:10/01/2020 (954)233-1330 S COPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of constructionmaterialsintheStateofFlorida.ThedocumentationsubmittedhasbeenreviewedbyRobertNieminen, P.E.foruseoftheproductundertheFloridaBuildingCode.Theproductdescribedhereinhasbeenevaluatedfor th compliancewiththe 7Edition(2020) FloridaBuildingCode,HighVelocityHurricaneZone sectionsnotedherein. D ESCRIPTION:PolyglassModifiedBitumenRoofSystems L ABELING:Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. ONTINUED C OMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced C Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s).NEMO ETC, LLC requires a completereviewofits EvaluationReportrelative toupdatedCoderequirementswitheach CodeCycle. DVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words “NEMO|etc. Evaluated” may be A displayed in advertising literature.If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. I NSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or itsdistributorsandshallbeavailableforinspectionatthe jobsiteattherequestofthe BuildingOfficial. ThisEvaluationReportconsistsofpages1through5,plusan83-pageAppendix. Preparedby: RobertJ.M.Nieminen,P.E. The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 10/01/2020. This does not serve as an FloridaRegistrationNo.59166,FloridaDCAANE1983 electronicallysigned document. C ERTIFICATIONOF I NDEPENDENCE: 1.NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributingproductsitevaluates. 2.NEMOETC,LLCisnotowned,operatedorcontrolledbyanycompanymanufacturingordistributingproductsitevaluates. 3.Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for whichthe evaluationreports arebeing issued. 4.Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5.This is a building code evaluation.Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specificallyforthatpurpose. ©2018,NEMOETC,LLC N EMO|etc. R OOFING S YSTEMS E VALUATION: 1.S COPE: ProductCategory:Roofing Sub-Category:ModifiedBitumenRoofSystems Compliance Statement:Polyglass Modified Bitumen Roof Systems, as produced by Polyglass USA, Inc., have th Edition(2020)FloridaBuildingCode,HighVelocity demonstratedcompliancewiththefollowingsectionsofthe 7 Hurricane Zone (HVHZ) through testing in accordance with the following Standards. Compliance is subject to the InstallationRequirements and Limitations/ConditionsofUse set forthherein. 2.S TANDARDS: SectionPropertyStandardYear TAS110ResistancetoFootTrafficTAS114,Section 8.92011 TAS110WindresistanceTAS114,AppendixC,DorJ2011 TAS110SusceptibilitytoHailDamageTAS114,AppendixF2011 TAS110SusceptibilitytoLeakageTAS114,AppendixG2011 TAS110MaterialstandardASTMD21782015 TAS110MaterialstandardASTMD46012012 TAS110MaterialstandardASTMD48972009 TAS110MaterialstandardASTMD61622015 TAS110MaterialstandardASTMD61632015 TAS110MaterialstandardASTMD61642011 TAS110MaterialstandardASTMD62222011 TAS110MaterialstandardASTMD65092015 3.R EFERENCES: EntityExamReferenceDateEntityExamReferenceDate ERD(TST6049)PhysicalsP10490.10.08-210/30/2008 FM(TST1867)FM4470300611505/02/2001 ERD(TST6049)FM4470/4474 P13760.09.0909/10/2009 FM(TST1867)FM4470301232107/29/2002 ERD(TST6049)FM4470/4474 P13770.09.0909/10/2009FM(TST1867)FM4470301469208/05/2003 ERD(TST6049)FM4470/4474 P30540.11.09-R111/30/2009 FM(TST1867)FM4470301475108/27/2003 ERD(TST6049)FM4470/4474 P30550.12.0912/02/2009 FM(TST1867)FM4470300717001/13/2004 ERD(TST6049)PhysicalsP33960.12.1012/30/2010 FM(TST1867)FM4470301931706/30/2004 ERD(TST6049)FM4470/4474 P33970.03.1103/15/2011 FM(TST1867)FM4470302070307/30/2004 ERD(TST6049)PhysicalsP37590.03.13-3A03/06/2013 FM(TST1867)FM4470/4474 301833201/31/2006 ERD(TST6049)FM4470/4474 P39680.03.1303/04/2013 FM(TST1867)FM4470/4474 302336803/20/2006 ERD(TST6049)PhysicalsP37590.03.13-1-R106/26/2013 FM(TST1867)FM4470/4474 302459405/23/2006 ERD(TST6049)PhysicalsP37590.03.13-2-R107/01/2013 FM(TST1867)FM4470/4474 302345807/18/2006 ERD(TST6049)PhysicalsP37590.07.13-207/01/2013 FM(TST1867)FM4470/4474 303066809/12/2007 ERD(TST6049)PhysicalsP37590.03.13-5-R1 07/01/2013 FM(TST1867)FM4470/4474 303217206/12/2009 ERD (TST6049) Physicals P37590.07.13-1 07/02/2013 FM(TST1867)FM4470/4474 304963104/21/2014 ERD (TST6049) FM 4470/4474 P41630.08.13 08/06/2013FM(TST1867)FM4470/4474 305702902/02/2017 4S-PLYG-18-001.06.18 ERD (TST6049) Physicals P45940.09.13 09/04/2013NEMO(TST6049)Criticality06/23/2018 4L-PLYG-18-003.08.18 ERD (TST6049) Physicals P44370.10.13 10/04/2013 NEMO(TST6049)FM447408/21/2018 4S-PLYG-18-001.10.18 ERD (TST6049) Physicals P39520.09.14-2 09/11/2014 NEMO(TST6049)Criticality10/03/2018 4S-PLYG-18-002.11.18-2 ERD (TST6049) FM 4470/4474 SC6160.11.14 11/10/2014 NEMO(TST6049)ASTMD489711/16/2018 4S-PLYG-18-002.11.18-3 ERD (TST6049) Physicals P45440SC.03.15-1 03/31/2015 NEMO(TST6049)ASTMD616411/28/2018 4L-PLYG-18-003.11.18 ERD (TST6049) Physicals SC5170.05.15 05/08/2015 NEMO(TST6049)FM447411/28/2018 4L-PLYG-18-003.01.19 ERD (TST6049) FM 4474 SC8085.05.15 05/19/2015 NEMO(TST6049)FM447401/11/2019 4S-PLYG-18-002.01.19-A ERD (TST6049) Physicals SC5170.12.15 12/29/2015 NEMO(TST6049)ASTMD616301/24/2019 4S-PLYG-18-002.01.19-B ERD (TST6049) FM 4470/4474 SC9455.15 04/01/2016 NEMO(TST6049)ASTMD616201/25/2019 4L-PLYG-18-003.04.19-A ERD (TST6049) FM 4470/4474 PLYG-SC8905.05.16-1 05/17/2016 NEMO(TST6049)FM447404/08/2019 4S-PLYG-18-002.05.19-C ERD (TST6049) FM 4470/4474 PLYG-SC8905.05.16-2 05/17/2016 NEMO(TST6049)ASTMD622205/20/2019 PLYG-SC10815.07.16-R1 4S-PLYG-18-002.05.19-D ERD (TST6049) FM 4470/4474 09/23/2016 NEMO(TST6049)ASTMD622205/20/2019 4S-PLYG-18-002.05.19-H ERD (TST6049) UL 1897 PLYG-SC12025.10.16 10/12/2016 NEMO(TST6049)ASTMD6163 05/20/2019 4S-PLYG-18-002.05.19-N ERD (TST6049) FM 4470/4474 PLYG-SC11475.16 11/17/2016 NEMO (TST6049) ASTM D6164 05/31/2019 ERD (TST6049) FM 4470/4474 PLYG-SC13235.01.17 01/17/2017 4S-PLYG-18-001.06.19.A NEMO (TST6049) Criticality 07/17/2019 4S-PLYG-18-002.09.19-I ERD (TST6049) FM 4470/4474 PLYG-SC13920.05.17 05/30/2017 NEMO (TST6049) ASTM D6164 09/06/2019 PLYG-CTL13945.05.17-1 4S-PLYG-18-002.09.19-J ERD (TST11294) FM 4470/4474 05/30/2017 NEMO (TST6049) ASTM D6164 09/06/2019 PLYG-CTL13945.05.17-3 4a-PLYG-20-LSWUS-01.A ERD (TST11294) FM 4470/4474 05/30/2017 NEMO (TST6049) FM 4474 08/28/2020 ERD (TST6049) FM 4470/4474 PLYG-SC13945.05.17 05/30/2017 PRI (TST5878) Physicals PUSA-062-02-01 12/04/2007 ERD (TST6049) FM 4470/4474 PLYG-SC15760.09.17 09/11/2017 PRI (TST5878) Physicals PUSA-061-02-02 01/28/2008 FM (TST1867) FM 4470 2W7A7.AM 08/04/1994 PRI (TST5878) Physicals PUSA-064-02-02 02/27/2008 FM(TST1867)FM44700D3A3.AM04/04/1997 PRI(TST5878) Physicals PUSA-062-02-02 12/04/2008 NEMOETC,LLCEvaluationReportP40690.12.13-1-R11 TH 7EDITION(2020)FBCHVHZ EVALUATION CertificateofAuthorization#32455 FL16717-R10 PolyglassModifiedBitumenRoofSystemsRevision11:10/01/2020 Page2of 5 N EMO|etc. EntityExamReferenceDateEntityExamReferenceDate FM(TST1867)FM44702D0A0.AM12/23/1998PRI(TST5878)TAS114PUSA-188-02-0102/08/2017 FM(TST1867)FM44702D5A9.AM06/22/1999PRI(TST5878)TAS114PUSA-188-02-0202/08/2017 FM(TST1867)FM4470300664601/04/2000PRI(TST5878)TAS114PUSA-188-02-0302/08/2017 FM(TST1867)FM4470300133401/25/2000PRI(TST5878)TAS114PUSA-202-02-0105/17/2017 FM(TST1867)FM4470300133402/15/2000PRI(TST5878)TAS114PUSA-202-02-0205/17/2017 FM(TST1867)FM4470300085701/12/2000M-D(CER1592)HVHZVariousNOAsVarious FM(TST1867)FM4470300409101/12/2000M-D(CER1592)Prop.forRev.10-082310/12/2010 UL(QUA9625)QualityControlServiceConfirm09/13/2018 4.P RODUCT D ESCRIPTION: ThisEvaluationReportcovers PolyglassModifiedBitumenRoofSystems installedinaccordancewith Polyglass USA,Inc.publishedinstallationinstructionsandtheLimitations/ConditionsofUseherein. T ABLE 1:R OLL-G OODSFOR M ODIFIED B ITUMEN R OOF S YSTEMS MaterialStandard TypeProductPlant(s) ReferenceTypeGrade PolyglassG2BaseASTMD4601IIN/AAL PolyflexSABaseASTMD4601IIN/AFL ElastobaseSAASTMD4601IIN/APA BaseSheets ElastoventASTMD4897N/AN/APA PolyglassBaseASTMD6509N/AN/AFL PolybondASTMD6222ISFL APP, Smooth-Surface PolyflexASTMD6222ISFL Membranes PolykoolASTMD6222ISFL Polybond GASTMD6222IGFL Polyflex GASTMD6222IGFL PolyflexG FRASTMD6222IGFL Polyfresko GASTMD6222IGNV APP, Granule-Surface PolyfreskoG FRASTMD6222IGNV Membranes PolyflexSA PASTMD6222IGFL,TX PolyflexSA PFRASTMD6222IGTX PolyfreskoG SAASTMD6222IGNV PolyfreskoG SAFRASTMD6222IGNV ElastoshieldHTASTMD6162IIISFL ElastobaseASTMD6163ISFL ElastoflexVASTMD6163ISFL ElastoflexSAVASTMD6163ISFL,PA,TX ElastoflexSAVFRASTMD6163ISFL,PA,TX ElastoflexSAVPlusASTMD6163ISFL,TX SBS, Smooth-Surface ElastoflexSAVPlusFRASTMD6163ISFL,TX Membranes ElastobasePASTMD6164ISFL,TX ElastoflexSABaseHDASTMD6164ISPA,TX ElastoflexS6ASTMD6164ISFL ElastoflexS6HPASTMD6164IISNV PolyreflectASTMD6164ISFL T ABLE 1:R OLL-G OODSFOR M ODIFIED B ITUMEN R OOF S YSTEMS MaterialStandard TypeProductPlant(s) ReferenceTypeGrade ElastoshieldHT GASTMD6162IIIGFL ElastoshieldHTGFRASTMD6162IIIGFL ElastoflexV GASTMD6163IGFL,PA SBS,GranuleSurface ElastoflexVGFRASTMD6163IGFL,PA Membranes ElastoflexS6GASTMD6164IGFL,PA ElastoflexS6GFRASTMD6164IGFL NEMOETC,LLCEvaluationReportP40690.12.13-1-R11 TH 7EDITION(2020)FBCHVHZ EVALUATION CertificateofAuthorization#32455 FL16717-R10 PolyglassModifiedBitumenRoofSystemsRevision11:10/01/2020 Page3of 5 N EMO|etc. T ABLE 1:R OLL-G OODSFOR M ODIFIED B ITUMEN R OOF S YSTEMS MaterialStandard TypeProductPlant(s) ReferenceTypeGrade ElastoshieldTSGASTMD6164IGFL,TX ElastoshieldTSGFRASTMD6164IGFL,TX ElastoflexSAPASTMD6164IGFL,TX ElastoflexSAPFRASTMD6164IGFL,TX 5.L IMITATIONS: 5.1ThisisaBuildingCodeEvaluation.NeitherNEMOETC,LLCnorRobertNieminen,P.E.are,inanyway,theDesigner ofRecordforanyprojectonwhichthisEvaluationReport,orpreviousversionsthereof,is/wasusedforpermitting ordesign guidanceunless retainedspecifically for thatpurpose. 5.2ThisEvaluationReportisnotforuseinNon-HighVelocityHurricaneZonejurisdictions. 5.3The evaluation herein pertains to above-deck roof components; deck-attachment details pertain to ‘as-tested’ conditions under Testing Application Standard TAS 114, Appendix J.Roof decks shall be in accordance with FBC HVHZ requirementsto thesatisfactionof the Authority Having Jurisdiction. 5.4ThisEvaluationReportdoesnotincludeevaluationoffireclassification.Referto FBCHVHZ1516 forrequirements and limitations regarding roof assembly fire classification.Refer to FBC 2603 for requirements and limitations concerningtheuse offoamplastic insulation. 5.5This Evaluation Report does not include evaluation of roof edge termination.Refer to Roofing Application StandardRAS111 forrequirementsand limitationsregardingedgesecurementfor low-sloperoofs. 5.6Referto FBCHVHZ1521 forrequirementsandlimitationsregardingrecoverinstallations. 5.6.1For mechanically attached components over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance.A qualified design professional shall review the data for comparison to the minimum requirementsforthesystem.Testingshallbeinaccordancewith TestingApplicationStandardTAS105. 5.6.2For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed.If any surfaceconditionsexistthatbringsystemperformanceintoquestion,fielduplifttestinginaccordancewith Testing ApplicationStandard TAS124 shallbeconducted onmock-upsoftheproposednewroof assembly. 5.6.3Forbondedinsulationormembraneoverexistingsubstratesinarecoverinstallation,theexistingroofsystemshall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction,asdocumentedthroughfielduplifttestinginaccordancewith TestingApplicationStandardTAS124. 5.7RefertoAppendix1forsystemattachmentrequirementsfor windloadresistance. 5.7.1“MDP”=MaximumDesignPressureistheresultoftestingforwindloadresistancebasedonallowablewindloads, andreflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per Testing Application StandardTAS114 hasalready beenapplied).Referto FBCHVHZ1620 and RoofingApplicationStandardRAS128 fordetermination ofdesignwind loads. 5.7.2For mechanically attached components, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with FBC HVHZ 1620 or Roofing Application Standard RAS 128.Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria.Analysis shall be in accordance with Roofing ApplicationStandardRAS117 or RoofingApplicationStandardRAS137.*Thisextrapolationisnotpermittedfor systemsmarked with anasterisk*. 5.7.3Forassembliesmarkedwithanasterisk*,themaximumdesignpressure(MDP)limitationshallbeapplicabletoall roofpressurezones. Rationalanalysis is notpermitted. NEMOETC,LLCEvaluationReportP40690.12.13-1-R11 TH 7EDITION(2020)FBCHVHZ EVALUATION CertificateofAuthorization#32455 FL16717-R10 PolyglassModifiedBitumenRoofSystemsRevision11:10/01/2020 Page4of 5 N EMO|etc. 5.8All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. Refer to the Product Approval of the component manufacturer for components listed in Appendix 1 that are producedbyaProductManufacturerotherthanthereportholderonPage1ofthisEvaluationReport. 6.I NSTALLATION: PolyglassModifiedBitumenRoofSystems shallbeinstalledinaccordancewith PolyglassUSA,Inc.published installationinstructions,subjecttotheLimitations/ConditionsofUsenotedherein. 7.B UILDING P ERMIT R EQUIREMENTS: AsrequiredbytheBuildingOfficialorAuthorityHavingJurisdictiontoproperlyevaluatetheinstallationofthis product. 8.M ANUFACTURING P LANTS: ContactthenamedQAentityformanufacturingfacilitiescoveredby F.A.C.Rule61G20-3 QArequirements.Refer toSection4hereinforproductsandproductionlocationshavingmetcodifiedmaterialstandards. 9.Q UALITY A SSURANCE E NTITY: ULLLC–QUA9625;(414)248-6409,karen.buchmann@ul.com -THE83-PAGESTHATFOLLOWFORMPARTOFTHISEVALUATIONREPORT - NEMOETC,LLCEvaluationReportP40690.12.13-1-R11 TH 7EDITION(2020)FBCHVHZ EVALUATION CertificateofAuthorization#32455 FL16717-R10 PolyglassModifiedBitumenRoofSystemsRevision11:10/01/2020 Page5of 5 N EMO|etc. A PPENDIX 1:A TTACHMENT R EQUIREMENTSFOR W IND U PLIFT R ESISTANCE TABLEDECKAPPLICATIONTYPEDESCRIPTIONPAGE 1AWoodNeworReroof(Tear-Off)A-2Mech.AttachedAnchorSheet,BondedInsulation,BondedRoofCover6-12 1BWoodNew,Reroof(Tear-Off)orRecoverA-2Mech.AttachedAnchorSheet,BondedInsulation,BondedRoofCover12-14 1CWoodNew,Reroof(Tear-Off)orRecoverB-1Mech.AttachedBaseInsulation,BondedTopInsulation,BondedRoofCover14 1DWoodNew,Reroof(Tear-Off)orRecoverC-1Mech.AttachedInsulation,BondedRoofCover15-17 1EWoodNew,Reroof(Tear-Off)orRecoverD-2Insulated,Mech.AttachedBaseSheet,Bonded RoofCover17-21 1FWoodNeworReroof(Tear-Off)E-2Non-Insulated,Mech.AttachedBaseSheet,BondedRoofCover21-25 1GWoodNew,Reroof(Tear-Off)orRecoverE-2Non-Insulated,Mech.AttachedBaseSheet,BondedRoofCover25-32 2ASteelorStructuralConcreteNew,Reroof(Tear-Off)orRecoverB-1Mech.AttachedBaseInsulation,BondedTopInsulation,BondedRoofCover33-35 2BSteelorStructuralConcreteNew,Reroof(Tear-Off)orRecoverC-1Mech.AttachedInsulation,BondedRoofCover36-40 2CSteelorStructuralConcreteNew,Reroof(Tear-Off)orRecoverD-2Insulated,Mech.AttachedBaseSheet,Bonded RoofCover41-42 2DSteelorStructuralconcreteNew,Reroof(Tear-Off)orRecoverD-2Insulated,Mech.AttachedVelociflex,Bonded RoofCover43-44 3AStructuralConcreteNeworReroof(Tear-Off)A-1BondedInsulation,BondedRoofCover45-57 3BStructuralConcreteNeworReroof(Tear-Off)FNon-Insulated,BondedRoofCover58 4ALightweightconcreteNeworReroof(Tear-Off)A-1BondedInsulation,BondedRoofCover59-63 4BLightweightconcreteNeworReroof(Tear-Off)A-2Mech.AttachedAnchorSheet,BondedInsulation,BondedRoofCover64 4CLightweightconcreteNeworReroof(Tear-Off)E-2Non-Insulated,Mech.AttachedBaseSheet,BondedRoofCover65-68 5ACementitiouswoodfiberReroof(Tear-Off)A-1BondedInsulation,BondedRoofCover69-70 5BCementitiouswoodfiberReroof(Tear-Off)orRecoverA-2Mech.AttachedAnchorSheet,BondedInsulation,BondedRoofCover70-71 5CReroof(Tear-Off)orRecoverB-1Mech.AttachedBaseInsulation,BondedTopInsulation,BondedRoofCover71 Cementitiouswoodfiber 5DCementitiouswoodfiberReroof(Tear-Off)orRecoverC-1Mech.AttachedInsulation,BondedRoofCover72 5ECementitiouswoodfiberReroof(Tear-Off)orRecoverE-2Non-Insulated,Mech.AttachedBaseSheet,BondedRoofCover72 6AExistinggypsumReroof(Tear-Off)A-1BondedInsulation,BondedRoofCover73-76 6BExistinggypsumNew,Reroof(Tear-Off)orRecoverA-2Mech.AttachedAnchorSheet,BondedInsulation,BondedRoofCover77 6CExistinggypsumNew,Reroof(Tear-Off)orRecoverC-1Mech.AttachedInsulation,BondedRoofCover77 6DExistinggypsumNew,Reroof(Tear-Off)orRecoverE-2Non-Insulated,Mech.AttachedBase Sheet,BondedRoofCover77 7AVariousRecoverA-1BondedInsulation,BondedRoofCover78-83 7BVariousRecoverFNon-Insulated,BondedRoofCover83 NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 1of83 N EMO|etc. Thefollowingnotesapplytothesystemsoutlinedherein: 1The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC HVHZ requirements to the satisfactionof the Authority Having Jurisdiction. Deck-attachment details pertain to ‘as-tested’ conditions under Testing Application Standard TAS 114, Appendix J. The table below provides reference to various as-tested deck sub-assemblies and associatedmaximumallowable design pressures. POLYGLASSAS-TESTEDDECKATTACHMENTDETAILS;TAS114,APPENDIXJ TESTEDFASTENERSPACINGHIGHESTAS-TESTEDALLOWABLE TYPETESTEDSPAN(FTO.C.)TESTEDFASTENING (INCHO.C.)PRESSURE(PSF) 15/32-inchplywood 28dringshanknails6-75.0 15/32-inchplywood 2#10woodscrews6-90.0 15/32-inchplywood 2#10woodscrews4-120.0 19/32-inchplywood 28dringshanknails6-60.0 19/32-inchplywood 2#10woodscrews6-127.5 22ga.,TypeB,Grade33steel 6Tek/5screws6-112.5 22ga.,TypeB,Grade40steel 65/8”puddlewelds6-97.5 22ga.,TypeB,Grade40steel 6Traxx/5screwswith¾”washers6-135.0 2Unlessotherwisenoted,fastenersandstressplatesshallbeasfollows.Fastenersshallbeofsufficientlengthforthefollowingengagements: WoodDeck:FirestoneInsulationFasteningPlateswithFirestoneAll-PurposeFasteners;FirestonePre-AssembledFastenerandPlate(consistingof0.196-inchthreaddiameterfastenerwith3-inch diametermetal plate).Minimum1-inchplywoodpenetrationorwoodplankembedment. SteelDeck:Firestone Insulation Fastening Plates with Firestone All-Purpose FastenersorFirestone Heavy-Duty Fasteners;FirestonePre-Assembled Fastener and Plate (consisting of 0.196-inch thread diameter fastener with 3-inch diameter metal plate); Firestone Pre-Assembled Heavy-Duty Fastener and Plate (consisting of 0.275-inch thread diameter fastener with 3-inch diametermetal plate);AP AccuTrac;HDAccuTrac.Minimum0.75-inchsteel penetrationandengagethetopfluteofthesteeldeck. Structural Concrete: Firestone Insulation Fastening Plates with Firestone Heavy-Duty Fasteners or Firestone Concrete Drive Fasteners; Firestone Pre-Assembled Heavy-Duty Fastener and Plate (consisting of 0.275-inch thread diameter fastener with 3-inch diameter metal plate); HD AccuTrac.Minimum 1-inch embedment into pilot hole in accordance with published installation instructions. 3Unlessotherwisenoted,insulationmaybeanyonelayerorcombinationofFBCApproved(LocalorStatewide)board(s)thatmeetFBCHVHZ1516and,forfoamplastic,FBCChapter26,wheninstalledwiththe roofcover. 4If mechanical attachment to the structural deck through lightweight insulating concrete is proposed, field withdrawal resistance testing shall be performed to confirm equivalent or determine enhanced fastening patterns and density.All testing and fastening design shall be in compliance with Testing Application Standard TAS 105 and Roofing Application Standard RAS 117 and/or RAS 137.Calculations shall beprepared, signedandsealed byaqualifieddesignprofessional. 5PreliminaryinsulationattachmentforSystemTypeD:Minimumfourfastenersper4x8ftboardorminimumtwofastenersper4x4ftboard. 6Unlessotherwisenoted,insulationadhesiveapplicationratesareasfollows.Ribbonorbeadwidthisatthetimeofapplication;theribbons/beadsshallexpandasnotedinthemanufacturer’spublished instructions. Hotasphalt(HA):Fullcoverageat25-30lbs/square. DuPontINSTASTIKQuikSetInsulationAdhesive(D-IS):Continuous0.75to1-inchwideribbons,12-incho.c. H.B.FullerMillenniumOneStepFoamableAdhesive(M-OSFA):Continuous0.25to0.5-inchwideribbons,12-incho.c. H.B.FullerMillenniumPG-1PumpGradeAdhesive(M-PG1):Continuous0.25to0.5-inchwideribbons,12-incho.c. OMGOlyBond500(OB500):Continuous0.75to1-inchwideribbons,12-incho.c.Note:OlyBondGreenmaybeusedwhereOlyBond500isreferenced. OlyBondClassic(OBClassic):Fullcoverageat1gal/square. ICPAdhesive&SealantsPolysetCR-20:Continuous2.5-3.5-inchwideribbons,12-incho.c. Note:Whenmultiplelayers(s)ofinsulationand/orcoverboardareinstalledinribbon-appliedadhesive,boardjointsshallbe staggered. NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 2of83 N EMO|etc. Note:Themaximumedgedistancefromtheadhesiveribbontotheedgeoftheinsulationboardshallbenotlessthanone-halfthespecifiedribbonsspacing. 7Unlessotherwisenoted,allinsulationsareflat-stockortaperboardoftheminimumthicknessnoted.Taperedpolyisocyanurateatthefollowingthicknesslimitationsmaybesubstitutedwiththefollowing Maximum Design Pressure (MDP) limitations. In no case shall these values be used to ‘increase’ the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in thetables,then the thinnerboardlisted belowmay beusedasa drop-inforthe equivalent thicker materiallisted in the table. H.B.FullerMillenniumOneStepFoamableAdhesive(M-OSFA):MDP=-157.5psf(Min.0.5-inchthick) H.B.FullerMillenniumPG-1Pump GradeAdhesive(M-PG1):MDP=-157.5psf(Min.0.5-inchthick) OMGOlyBond500(OB500):MDP= -45.0psf(Min.0.5-inchthickMulti-MaxFA-3) OMGOlyBond500(OB500):MDP=-187.5psf(Min.0.5-inchthickISO95+GL) OMGOlyBond500(OB500):MDP=-315.0psf(Min.0.5-inchthickENRGY3) OMGOlyBond500(OB500):MDP=-487.5psf(Min.0.5-inchthickACFoamII) ICPAdhesives&SealantsPolysetCR-20:MDP=-117.5psf(Min.1.0-inchthick) 8Bondedpolyisocyanurateinsulationboardsshallbemaximum4x 4ft. 9Formechanicallyattachedcomponents,themaximumdesignpressurefortheselectedassemblyshallmeetorexceedatleasttheZone1PRIMEdesignpressuredeterminedinaccordancewithFBCHVHZ1620 or Roofing Application Standard RAS 128. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria in accordance with RoofingApplicationStandardRAS 117orRoofing ApplicationStandardRAS137.*Thisextrapolationisnot permittedforsystemsmarked withanasterisk* 10For assemblies marked with an asterisk*, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysisispermitted forthese systems. 11For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance in accordance with Testing Application Standard TAS 105. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Should the fastener resistance be less than that required, a revised fastener spacing –prepared, signed and sealed by a qualified design professional in accordance with Roofing Application Standard RAS 117 or Roofing Application Standard RAS 137 –may be submitted to the Building Official for review and acceptance. 12Refer to FBC HVHZ 1521 for requirements and limitations regarding recover installations. For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance shall be conducted on mock-ups of the proposed new roof assembly. For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting projectdesignpressuresonitsownmerittothesatisfactionoftheAuthorityHavingJurisdiction,asdocumentedthroughfielduplifttestinginaccordancewithTestingApplicationStandardTAS124. 13For Structural Concrete Deck or Recover Applications using System Type C-1, C-2, D-1 or D-2, the insulation is optional. Alternatively, an FBC HVHZ Approved insulation board or coverboard may be used as a separation layer. Board products shall be preliminarily attached prior to roof cover installation (Note 5 herein). The separator component shall be documented as meeting FBC HVHZ 1516 and, for foam plastic, FBCChapter26, wheninstalled withtheroof coverin Recoverapplications. 14Lightweight insulating concrete (LWIC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the AuthorityHaving Jurisdiction. For systems where specific LWIC is referenced, refer to current LWIC FBC HVHZ Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWIC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top-coat thickness is 2-inches. For LWIC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. For “pre-existent” LWIC references, listings were established through testing over lightweight concrete cast using only foaming agent (ASTM C896), water and Portland cement (ASTM C150), with no proprietary additives, in accordance with procedures adopted by Miami-Dade BCCO(FBCCER1592).Useofthese listingsinnewconstructionorre-roof(tear-off)applicationsisatthediscretionoftheDesigner orRecordandAuthorityHavingJurisdiction. NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 3of83 N EMO|etc. 15Forbondedmembraneapplications,unlessotherwisenoted,refertothefollowing. M EMBRANE /A DHESIVE C OMBINATIONS REFERENCELAYERMATERIALAPPLICATION BasePlyOneormorepliesPolyglassG2Base,FBCApprovedASTMD4601,TypeII BP-AA HotAsphaltat20-40 PlyOneormorepliesPolyglassPlyIV,PolyglassPlyVI, FBCApprovedASTMD2178,TypeIVorVI (Baseand Plysheets, lbs/square Asphalt-Applied)Note:Asphalt-appliedsheetsorinsulationshallnotbeappliedtopoly-filmsurfacedmembranes. BasePlyOneplyElastobase(sand/sand),ElastoflexV,ElastoflexS6,ElastoflexS6HP,ElastoshieldHT PG350at1.5-2.0 SBS-CA1 ElastoshieldHTG,ElastoshieldHTGFR,ElastoflexVG,ElastoflexVGFR,ElastoflexS6,ElastoflexS6HP,ElastoflexS6G,Elastoflex CapPlygal/square S6GFR,ElastoshieldTSG,ElastoshieldTSGFR,PolyfreskoGSBS(sand-backed),PolyfreskoGSBSFR(sand-backed) BasePlyOneplyElastobase(sand/sand),ElastoflexV,ElastoflexS6,ElastoflexS6HP Polyplus 35 at 1.5-2.0 SBS-CA2 ElastoshieldHTG,ElastoshieldHTGFR,ElastoflexVG,ElastoflexVGFR,ElastoflexS6,ElastoflexS6HP,ElastoflexS6G,Elastoflex CapPlygal/square S6GFR,ElastoshieldTSG,ElastoshieldTSGFR,PolyfreskoGSBS(sand-backed),PolyfreskoGSBSFR(sand-backed) OneormorepliesElastobase(sand/sandorpoly/sand),ElastobaseP(sand/sandorpoly/sand),ElastoflexV,ElastoflexS6,Elastoflex BasePlyorPly S6HP,ElastoshieldHT SBS-AAHotAsphaltat20-40 ElastoshieldHTG,ElastoshieldHTGFR,ElastoflexV,ElastoflexVG,ElastoflexVGFR,ElastoflexS6,ElastoflexS6HP,ElastoflexS6G, (SBS,Asphalt-Applied)CapPlylbs/square ElastoflexS6GFR,ElastoshieldTSG,ElastoshieldTSGFR,PolyfreskoGSBS(sand-backed),PolyfreskoGSBSFR(sand-backed) Note:Asphalt-appliedsheetsorinsulationshallnotbeappliedtopoly-filmsurfacedmembranes. BasePlyorPlyOneormorepliesElastobase(sand/poly),Elastobase(poly/poly), ElastoflexV,ElastoflexS6,ElastoflexS6HP,ElastoshieldHT SBS-TA ElastoshieldHTG,ElastoshieldHTGFR,ElastoflexV,ElastoflexVG,ElastoflexVGFR,ElastoflexS6,ElastoflexS6HP,ElastoflexS6 Torch-Applied (SBS,Torch-Applied) CapPlyG,ElastoflexS6GFR,ElastoshieldTSG,ElastoshieldTSGFR,PolyfreskoGSBS(poly-filmbacked),PolyfreskoGSBSFR(poly-film backed) Self-adhering (followed SBS-SA-H BasePlyElastobaseSA bytorch-appliedsheet) (SBS,Self-Adhering,HybridSystems) BasePlyOneormorepliesElastoflexSAV,ElastoflexSAVFR,ElastoflexSAVPlus,ElastoflexSAVPlusFR,ElastoflexSABaseHD CapPlyElastoflexSAP,ElastoflexSAPFR,Polyreflect SBS-SA Self-Adhering (SBS,Self-Adhering) Note:Unlessotherwisenoted,permissiblemembranesubstratesforSBS-SAarelimitedtotheSBS-SABasePlyoptionsherein, Elastobase(poly/sand)orElastobase(poly/poly). PG350at1.5-2.0 APP-CA1CapPlyPolyflexGFR gal/square BasePlyorPlyOneormorepliesPolyglassBase,Polyflex,Polybond APP-TA Torch-Applied (APP,Torch-Applied)CapPlyPolyflex,PolyflexG,PolyflexGFR,Polybond,PolybondG,Polyfresko G,PolyfreskoGFR Self-adhering(followed APP-SA-H BasePlyPolyflexSABase bytorch-appliedsheet) (APP,Self-Adhering,HybridSystems) CapPlyPolyflexSAP,PolyflexSAPFR,Polyfresko GSA,PolyfreskoGSAFR,Polykool APP-SA Note:Unlessotherwisenoted,permissiblemembranesubstratesforAPP-SAarelimitedtotheSBS-SABasePlyoptionsherein,Self-Adhering (APP,Self-Adhering) Elastobase(poly/sand)orElastobase(poly/poly). NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 4of83 N EMO|etc. 16VaporbarrieroptionsforuseoverstructuralconcretedeckfollowedbybondedinsulationcarrythefollowingMDPlimitations.ThelesseroftheMDPlistingsbelowvs.thoseinTable3Aapplies. V APOR B ARRIER O PTIONS;S TRUCTURAL C ONCRETE D ECK;F OLLOWEDBY A DHESIVE-A PPLIED I NSULATIONPER T ABLE 3A: VAPORBARRIER OPTIONMDP PRIMERINSULATIONADHESIVE #(PSF)* TYPE(NOTE 15)APPLICATION C-VB-1.PG100ElastoflexSAVPlusSelf-AdheringD-ISorCR-20,12-incho.c.-60.0 C-VB-2.PG100PolyglassBaseTorch-appliedD-ISorCR-20,12-incho.c.-75.0 C-VB-3.PG100ElastoflexSAPSelf-AdheringD-IS,12-incho.c.-75.0 C-VB-4.PG100ElastoflexSAPSelf-AdheringM-OSFA,12-incho.c.-157.5 C-VB-5.PG100ElastoflexSAPSelf-AdheringCR-20,12-incho.c.-270.0 ElastoflexSAV,ElastoflexSAVFR,ElastoflexSAVPlus,ElastoflexSAV M-OSFA,M-PG-1,OB500orCR-20,12-inch C-VB-6.PG100Self-Adhering-290.0 PlusFR o.c. M-OSFA,M-PG-1,OB500orCR-20,12-inch C-VB-7.PG100SBS-TA(withsanded-top-surface)Torch-applied-290.0 o.c. 17The following surfacing may be applied to the Cap Ply without adverse effect on the system wind load performance. Refer to current Florida Product Approval for approved Polyglass and KM Coatings roof coatings forapplicationlimitationsandaRoofingMaterialsDirectory for fire ratingsassociatedwithcoating usage. S URFACING O PTIONSFOR P OLYGLASS M ODIFIED B ITUMEN R OOF S YSTEMS OPTION#SURFACINGFLORIDAHVHZPRODUCTAPPROVAL SURF-1.PG30017-1031.01 SURF-2.PG60017-1031.01 SURF-3.PG65017-1031.01 SURF-4.PG70020-0611.01 SURF-5.PG700QS20-0611.01 SURF-6.PG80017-1031.01 SURF-7.Polyplus6017-1031.01 SURF-8.Polyplus6517-1031.01 SURF-9.PolyBrite60-FC20-0611.01 SURF-10.PolyBrite7020-0611.01 SURF-11.PolyBrite70QS20-0611.01 SURF-12.PolyBrite7520-0611.01 SURF-13.PolyBrite71HS20-0611.01 SURF-14.PolyBrite9019-0610.02 SURF-15.PolyBrite90.119-0610.02 SURF-16.PolyBrite9519-0610.02 SURF-17.PolyBrite95.119-0610.02 SURF-18.KMAcryl 1517-1031.01 SURF-19.KMAcryl 15QS17-1031.01 SURF-20.KMAcryl 2517-1031.01 SURF-21.KMAcryl 25QS17-1031.01 SURF-22.KMAcryl 40HS17-1031.01 SURF-23.KMAcryl 8517-1031.01 NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 5of83 N EMO|etc. S URFACING O PTIONSFOR P OLYGLASS M ODIFIED B ITUMEN R OOF S YSTEMS OPTION#SURFACINGFLORIDAHVHZPRODUCTAPPROVAL SURF-24.KMPS#25017-1031.01 SURF-25.KMPS#22017-1031.01 SURF-26.Turbo-Set19-0820.05 18“MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC (HVHZ) 1620 and Roofing Application Standard RAS 128 for determinationof design windloads. TABLE1A:WOODDECKS–NEWCONSTRUCTION OR REROOF(T EAR-O FF) SYSTEMTYPEA-2:MECHANICALLYATTACHEDANCHORSHEET,BONDEDINSULATION,BONDEDROOFCOVER AnchorSheetBaseInsulationTopInsulationRoofCover(Note15) Deck SystemMDP Base FastenAttachAttach No. (psf) (Note1) TypeAttachTypeTypePlyCapPly Ply (Note11)(Notes6,7,8)(Notes6,7,8) A SPHALT-A PPLIEDOR T ORCH-A PPLIED B ASE P LY: Min. 0.75-inch Fesco (Optional) Min. 1.5- 9-inch o.c. at 2-inchBoard Min.inch Polytherm, Elastobase,(homogeneous) orBP-AA(Optional)SBS-AA, lap and 18-inch o.c. 15/32-Simplex MAXXACFoamII,ENRGY-3, Elastobase Pin two (2), equallymin. 0.5-inchor SBS-BP-AA orSBS-TA, W-1.HotasphaltHotasphalt-45.0* inchCapPolytherm H, H-Shield, (sanded-top)spaced, staggeredStructodek HighAASBS-AAAPP-TA plywoodH-Shield CG, Multi- centerrowsDensityFiberboard MaxFA3 RoofInsulation (Optional) Min. 1.5- 9-inch o.c. at 2-inchMin.0.25-inchDensBP-AA, Min.inch Polytherm,(Optional) lap and 18-inch o.c.Deck, Dens DeckSBS- Elastobase,SBS-AA, 15/32-Simplex MAXXACFoamII,ENRGY-3,BP-AA, SBS- W-2.HotasphaltPrime,SECUROCKHotasphaltAA,SBS-TA,-45.0* Elastobase Pin two (2), equally inchCapPolythermH,H-Shield,AA, SBS-TA, (sanded-top)spaced, staggeredGypsum-Fiber RoofSBS-TA,APP-TA H-Shield CG, Multi-APP-TA plywood centerrowsBoardAPP-TA MaxFA3 Min. 0.75-inch Fesco (Optional) Min. 1.5- 9-inch o.c. at 2-inchBoard Min.inch Polytherm, Elastobase,(homogeneous) orBP-AA(Optional)SBS-AA, lap and 12-inch o.c. 15/32-Simplex MAXXACFoamII,ENRGY-3, W-3.Elastobase Pin two (2), equallyHotasphaltmin. 0.5-inchHotasphaltBP-AA orSBS-TA,-52.5 or SBS- inchCapPolytherm H, H-Shield, (sanded-top)spaced, staggeredStructodek HighAASBS-AAAPP-TA plywoodH-Shield CG, Multi- centerrowsDensityFiberboard MaxFA3 RoofInsulation (Optional) Min. 1.5- 9-inch o.c. at 2-inchMin.0.25-inchDensBP-AA, Min.inch Polytherm,(Optional) Elastobase,lap and 12-inch o.c.Deck, Dens DeckSBS-SBS-AA, Simplex MAXX 15/32-ACFoamII,ENRGY-3,BP-AA, SBS- W-4.Elastobase Pin two (2), equallyHotasphaltPrime,SECUROCKHotasphaltAA,SBS-TA,-52.5 Cap inchPolytherm H, H-Shield,AA, SBS-TA, SBS-TA, (sanded-top)spaced, staggeredGypsum-Fiber RoofAPP-TA APP-TA plywoodH-Shield CG, Multi- centerrowsBoardAPP-TA MaxFA3 NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 6of83 N EMO|etc. TABLE1A:WOODDECKS–NEWCONSTRUCTION OR REROOF(T EAR-O FF) SYSTEMTYPEA-2:MECHANICALLYATTACHEDANCHORSHEET,BONDEDINSULATION,BONDEDROOFCOVER AnchorSheetBaseInsulationTopInsulationRoofCover(Note15) Deck SystemMDP FastenAttachAttachBase No.(psf) (Note1) TypeAttachTypeTypePlyCapPly Ply (Note11)(Notes6,7,8)(Notes6,7,8) Polyglass G2 Base, (Optional) Min. 1.5-Min. 0.75-inch Fesco 32ga.,1-5/8- Elastobase, Elastobase 8-inch o.c. in 4-inchinch Polytherm,Board Min. inch diameter P (sanded-top), lap and 8-inch o.c.ACFoam II, Polytherm(homogeneous) orBP-AA(Optional)SBS-AA, 19/32- Elastovent,tin caps with W-5.HotasphaltHotasphaltSBS-TA,-60.0 inthree(3),equallyG,ACFoamIII,ENRGY-min. 0.5-inchor SBS-BP-AA or CertainTeed Glasbase, inch11ga.annular spaced, staggered3, Polytherm H, H-Structodek High AASBS-AAAPP-TA Firestone MB Base, JM plywoodring shank centerrowsShield,H-ShieldCG,Density Fiberboard Perma-Ply28or nails Multi-MaxFA3RoofInsulation GAFGLAS#75 Polyglass G2 Base, (Optional) Min. 1.5- 32ga., 1-5/8- Elastobase, Elastobase 8-inch o.c. in 4-inchinch Polytherm,BP-AA, Min.inch diameterMin. 0.25-inch Dens(Optional) P (sanded-top), lap and 8-inch o.c.ACFoam II, PolythermSBS-SBS-AA, 19/32-Elastovent,tin caps withDeck Prime,BP-AA, SBS- W-6.inthree(3),equallyG,ACFoamIII,ENRGY-HotasphaltHotasphaltAA,SBS-TA,-60.0 CertainTeed Glasbase, inchSECUROCK Gypsum-AA, SBS-TA, 11ga.annular 3, Polytherm H, H- spaced, staggeredSBS-TA,APP-TA Firestone MB Base, JM plywoodring shankFiberRoofBoardAPP-TA centerrowsShield,H-ShieldCG,APP-TA Perma-Ply28or nails Multi-MaxFA3 GAFGLAS#75 Min. 0.75-inch Fesco 12-inch o.c. in 4-(Optional) Min. 1.5- Board inchlapand12-inchinch Polytherm, Min. Elastobase,(homogeneous) orBP-AA(Optional)SBS-AA, ACFoamII,ENRGY-3, 19/32-Simplex MAXXo.c. in two (2), W-7.Elastobase PHotasphaltmin. 0.5-inchHotasphaltor SBS-BP-AA orSBS-TA,-60.0 inchCapFastenersequally spaced,Polytherm H, H-Shield, (sanded-top)Structodek HighAASBS-AAAPP-TA plywoodstaggered centerH-Shield CG, Multi- Density Fiberboard rowsMaxFA3 RoofInsulation 12-inch o.c. in 4-(Optional) Min. 1.5- Min.0.25-inchDensBP-AA, Min.inchlapand12-inchinch Polytherm,(Optional) Elastobase,Deck, Dens DeckSBS-SBS-AA, Simplex MAXX 19/32-o.c. in two (2),ACFoamII,ENRGY-3,BP-AA, SBS- Prime,SECUROCKAA, W-8.Elastobase PHotasphaltHotasphaltSBS-TA,-60.0 Polytherm H, H-Shield,AA, SBS-TA, inchCapFastenersequally spaced, (sanded-top)Gypsum-Fiber RoofSBS-TA,APP-TA plywoodstaggered centerH-Shield CG, Multi-APP-TA BoardAPP-TA rowsMaxFA3 32ga.,1-5/8-(Optional) Min. 1.5- 8-incho.c.in4-inchBP-AA, Min.Elastobase,inch diameterinch Polytherm,Min. 0.25-inch Dens(Optional) SBS-SBS-AA, lap and 8-inch o.c. 15/32-Elastobase Ptin caps withACFoamII,ENRGY-3,Deck Prime,BP-AA, SBS- W-9.HotasphaltHotasphaltAA,SBS-TA,-67.5 in four (4), equally inch(sanded-top) or12ga.annularPolytherm H, H-Shield,SECUROCK Gypsum-AA, SBS-TA, spaced, staggeredSBS-TA,APP-TA Elastoventring shankFiberRoofBoardAPP-TA plywoodH-Shield CG, Multi- centerrowsAPP-TA nailsMaxFA3 NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 7of83 N EMO|etc. TABLE1A:WOODDECKS–NEWCONSTRUCTION OR REROOF(T EAR-O FF) SYSTEMTYPEA-2:MECHANICALLYATTACHEDANCHORSHEET,BONDEDINSULATION,BONDEDROOFCOVER AnchorSheetBaseInsulationTopInsulationRoofCover(Note15) Deck SystemMDP FastenAttachAttachBase No.(psf) (Note1) TypeAttachTypeTypePlyCapPly Ply (Note11)(Notes6,7,8)(Notes6,7,8) (Optional) Min. 1.5- 9-incho.c.in4-inchBP-AA, Min.inch Polytherm,Min. 0.25-inch Dens(Optional) lap and 9-inch o.c.SBS-SBS-AA, 15/32-Simplex MAXXACFoamII,ENRGY-3,Deck Prime,BP-AA, SBS- W-10.PolyglassG2Basein four (4), equallyHotasphaltHotasphaltAA,SBS-TA,-82.5 inchCapPolytherm H, H-Shield,SECUROCK Gypsum-AA, SBS-TA, SBS-TA, spaced, staggeredAPP-TA FiberRoofBoardAPP-TA plywoodH-Shield CG, Multi- centerrowsAPP-TA MaxFA3 32ga.,1-5/8-(Optional) Min. 1.5- 6-incho.c.in4-inchBP-AA, PolyglassG2Base, Min.inch Polytherm,Min. 0.25-inch Dens(Optional) inch diameter Elastobase,lap and 6-inch o.c.SBS-SBS-AA, 15/32-ACFoamII,ENRGY-3,Deck Prime,BP-AA, SBS- tin caps with SBS-TA, W-11.Elastobase Pin five (5) equallyHotasphaltHotasphaltAA,-90.0 inch12ga.annularPolytherm H, H-Shield,SECUROCK Gypsum-AA, SBS-TA, APP-TA (sanded-top) orspaced, staggeredSBS-TA, plywoodring shankH-Shield CG, Multi-FiberRoofBoardAPP-TA ElastoventcenterrowsAPP-TA nailsMaxFA3 (Optional) Min. 1.5- 6-inch o.c. at 2-inchBP-AA, Min.inch Polytherm,Min. 0.25-inch Dens(Optional) Elastobase,SBS-SBS-AA, lap and 6-inch o.c. Simplex MAXX 15/32-ACFoamII,ENRGY-3,Deck Prime,BP-AA, SBS- W-12.Elastobase Pin two (2), equallyHotasphaltHotasphaltAA,SBS-TA,-90.0 Polytherm H, H-Shield,SECUROCK Gypsum-AA, SBS-TA, inchCap (sanded-top)spaced, staggeredSBS-TA,APP-TA plywoodH-Shield CG, Multi-FiberRoofBoardAPP-TA centerrowsAPP-TA MaxFA3 32ga.,1-5/8- 6-incho.c.in4-inchMin. 2-inch Polytherm,D-IS, OB500,Min.0.25-inchDensBP-AA, Min.Elastobase,inch diameterD-IS,(Optional) lap and 6-inch o.c.ACFoamII, III,CR-20orM-Deck, Dens DeckSBS-SBS-AA, 19/32-Elastobase Ptin caps withOB500,CR-BP-AA, SBS- SBS-TA, W-13.in four (4), equallyPolytherm H, H-Shield,OSFA, atopPrime or SECUROCKAA,-60.0* inch(sanded-top) or12ga.annular20orM-AA, SBS-TA, spaced, staggeredH-Shield CG, Multi-fastener rows,Gypsum-Fiber RoofSBS-TA,APP-TA plywoodElastoventring shankOSFAAPP-TA centerrowsMaxFA3orENRGY-37-incho.c.BoardAPP-TA nails S ELF-A DHERING B ASE P LY: (Optional) Min. 1.5- 9-inch o.c. at 2-inchMin.0.25-inchDens Min.inch Polytherm,(Optional)SBS-SA, Elastobase,lap and 18-inch o.c.Deck, Dens Deck Simplex MAXX 15/32-ACFoamII,ENRGY-3,SBS-SA,APP-SA, W-14.Elastobase Pin two, equallyHotasphaltPrime,SECUROCKHotasphaltSBS-SA-45.0* CapPolytherm H, H-Shield,SBS-TA,SBS-TA, inch (sanded-top)spaced, staggeredGypsum-Fiber Roof plywoodH-Shield CG, Multi-APP-TAAPP-TA centerrowsBoard MaxFA3 (Optional) Min. 1.5- 9-inch o.c.at 2-inchMin.0.25-inchDens Min.inch Polytherm,(Optional)SBS-SA, Elastobase,lap and 12-inch o.c.Deck, Dens Deck 15/32-Simplex MAXXACFoamII,ENRGY-3,SBS-SA,APP-SA, W-15.HotasphaltPrime,SECUROCKHotasphaltSBS-SA-52.5 Elastobase Pin two, equally Polytherm H, H-Shield, inchCapSBS-TA,SBS-TA, (sanded-top)spaced, staggeredGypsum-Fiber Roof APP-TAAPP-TA plywoodH-Shield CG, Multi- centerrowsBoard MaxFA3 NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 8of83 N EMO|etc. TABLE1A:WOODDECKS–NEWCONSTRUCTION OR REROOF(T EAR-O FF) SYSTEMTYPEA-2:MECHANICALLYATTACHEDANCHORSHEET,BONDEDINSULATION,BONDEDROOFCOVER AnchorSheetBaseInsulationTopInsulationRoofCover(Note15) Deck SystemMDP FastenAttachAttachBase No.(psf) (Note1) TypeAttachTypeTypePlyCapPly Ply (Note11)(Notes6,7,8)(Notes6,7,8) Polyglass G2 Base, (Optional) Min. 1.5- 32ga.,1-5/8- Elastobase, Elastobase 8-inch o.c. in 4-inchinch Polytherm,Min.0.25-inchDens Min.(Optional)SBS-SA, inch diameter P (sanded-top), lap and 8-inch o.c.ACFoam II, PolythermDeck, Dens Deck 19/32-SBS-SA,APP-SA, Elastovent,tin caps with W-16.HotasphaltHotasphaltSBS-SA-60.0 inthree(3),equallyG,ACFoamIII,ENRGY-Prime,SECUROCK CertainTeed Glasbase, inch11ga.annularSBS-TA,SBS-TA, spaced, staggered3, Polytherm H, H- Gypsum-Fiber Roof Firestone MB Base, JM plywoodring shankAPP-TAAPP-TA centerrowsShield,H-ShieldCG,Board Perma-Ply28or nails Multi-MaxFA3 GAFGLAS#75 12-inch o.c. in 4-(Optional) Min. 1.5- Min.0.25-inchDens Min.inchlapand12-inchinch Polytherm,(Optional)SBS-SA, Deck, Dens Deck Elastobase, 19/32-Simplex MAXXo.c. in two (2),ACFoamII,ENRGY-3,SBS-SA,APP-SA, W-17.HotasphaltPrime,SECUROCKHotasphaltSBS-SA-60.0 Elastobase P inchCapFastenersequally spaced,Polytherm H, H-Shield,SBS-TA,SBS-TA, (sanded-top) Gypsum-Fiber Roof plywoodstaggered centerH-Shield CG, Multi-APP-TAAPP-TA Board rowsMaxFA3 32ga.,1-5/8- 6-incho.c.in4-inchMin. 2-inch Polytherm,D-IS, OB500, Min.D-IS,(Optional)SBS-SA, inch diameter Elastobase,(Optional) Additional lap and 6-inch o.c.ACFoamII, III,CR-20orM- 19/32-tin caps withOB500,CR-SBS-SA,APP-SA, W-18.Elastobase Pin four (4), equallyPolytherm H, H-Shield,OSFA, atoplayers of baseSBS-SA-60.0* SBS-TA,SBS-TA, inch12ga.annular20orM- (sanded-top)spaced, staggeredH-Shield CG, Multi-fastener rows,insulation plywoodring shankOSFAAPP-TAAPP-TA centerrowsMaxFA3orENRGY-37-incho.c. nails H YBRID S YSTEMSWITH S ELF-A DHERING APPB ASE P LY: (Optional) Min. 1.5- 9-inch o.c. at 2-inchMin.0.25-inchDens Min.inch Polytherm, lap and 18-inch o.c.Deck, Dens Deck Elastobase, 15/32-Simplex MAXXACFoamII,ENRGY-3,APP-(Optional) W-19.in two, equallyHotasphaltPrime,SECUROCKHotasphaltAPP-TA-45.0* Elastobase P inchCapPolytherm H, H-Shield,SA-HAPP-TA (sanded-top)spaced, staggered Gypsum-Fiber Roof plywoodH-Shield CG, Multi- centerrowsBoard MaxFA3 (Optional) Min. 1.5- 9-inch o.c. at 2-inchMin.0.25-inchDens Min.inch Polytherm, Elastobase,Deck, Dens Deck lap and 12-inch o.c. Simplex MAXXAPP-(Optional) 15/32-ACFoamII,ENRGY-3, W-20.Elastobase Pin two, equallyHotasphaltPrime,SECUROCKHotasphaltAPP-TA-52.5 CapPolytherm H, H-Shield,SA-HAPP-TA inch (sanded-top)spaced, staggeredGypsum-Fiber Roof plywoodH-Shield CG, Multi- centerrowsBoard MaxFA3 NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 9of83 N EMO|etc. TABLE1A:WOODDECKS–NEWCONSTRUCTION OR REROOF(T EAR-O FF) SYSTEMTYPEA-2:MECHANICALLYATTACHEDANCHORSHEET,BONDEDINSULATION,BONDEDROOFCOVER AnchorSheetBaseInsulationTopInsulationRoofCover(Note15) Deck SystemMDP FastenAttachAttachBase No.(psf) (Note1) TypeAttachTypeTypePlyCapPly Ply (Note11)(Notes6,7,8)(Notes6,7,8) Polyglass G2 Base, (Optional) Min. 1.5- 32ga.,1-5/8- Elastobase, Elastobase 8-inch o.c. in 4-inchinch Polytherm,Min.0.25-inchDens Min. inch diameter P (sanded-top), lap and 8-inch o.c.ACFoam II, PolythermDeck, Dens Deck 19/32-APP-(Optional) Elastovent,tin caps with W-21.HotasphaltHotasphaltAPP-TA-60.0 inthree(3),equallyG,ACFoamIII,ENRGY-Prime,SECUROCK CertainTeed Glasbase, inch11ga.annularSA-HAPP-TA spaced, staggered3, Polytherm H, H- Gypsum-Fiber Roof Firestone MB Base, JM plywoodring shank centerrowsShield,H-ShieldCG,Board Perma-Ply28or nails Multi-MaxFA3 GAFGLAS#75 12-inch o.c. in 4-(Optional) Min. 1.5- Min.0.25-inchDens Min.inchlapand12-inchinch Polytherm, Deck, Dens Deck Elastobase, 19/32-Simplex MAXXo.c. in two (2),ACFoamII,ENRGY-3,APP-(Optional) W-22.HotasphaltPrime,SECUROCKHotasphaltAPP-TA-60.0 Elastobase P inchCapFastenersequally spaced,Polytherm H, H-Shield,SA-HAPP-TA (sanded-top) Gypsum-Fiber Roof plywoodstaggered centerH-Shield CG, Multi- Board rowsMaxFA3 32ga.,1-5/8-(Optional) Min. 1.5- 8-incho.c.in4-inch PolyglassG2Base, Min.inch Polytherm,Min. 0.25-inch Dens inch diameter Elastobase,lap and 8-inch o.c. APP-(Optional) 15/32-tin caps withACFoamII,ENRGY-3,Deck Prime, W-23.Elastobase Pin four (4), equallyHotasphaltHotasphaltAPP-TA-67.5 Polytherm H, H-Shield,SECUROCK Gypsum-SA-HAPP-TA inch12ga.annular (sanded-top) orspaced, staggered plywoodring shankH-Shield CG, Multi-FiberRoofBoard Elastoventcenterrows nailsMaxFA3 (Optional) Min. 1.5- 9-incho.c.in4-inch Min.inch Polytherm,Min. 0.25-inch Dens lap and 9-inch o.c. 15/32-Simplex MAXXACFoamII,ENRGY-3,Deck Prime,APP-(Optional) W-24.PolyglassG2BaseHotasphaltHotasphaltAPP-TA-82.5 in four (4), equally Polytherm H, H-Shield, inchCapSECUROCK Gypsum-SA-HAPP-TA spaced, staggered FiberRoofBoard plywoodH-Shield CG, Multi- centerrows MaxFA3 32ga.,1-5/8-(Optional) Min. 1.5- PolyglassG2Base,6-incho.c.in4-inch inch Polytherm, Min.inch diameterMin. 0.25-inch Dens Elastobase,lap and 6-inch o.c. APP-(Optional) 15/32-tin caps withACFoamII,ENRGY-3,Deck Prime, W-25.Elastobase Pin five (5) equallyHotasphaltHotasphaltAPP-TA-90.0 inch12ga.annularPolytherm H, H-Shield,SECUROCK Gypsum-SA-HAPP-TA (sanded-top) orspaced, staggered plywoodring shankH-Shield CG, Multi-FiberRoofBoard Elastoventcenterrows nailsMaxFA3 (Optional) Min. 1.5- 6-inch o.c. at 2-inch Min.inch Polytherm,Min. 0.25-inch Dens Elastobase,lap and 6-inch o.c. 15/32-Simplex MAXXACFoamII,ENRGY-3,Deck Prime,APP-(Optional) W-26.Elastobase Pin two (2), equallyHotasphaltHotasphaltAPP-TA-90.0 inchCapPolytherm H, H-Shield,SECUROCK Gypsum-SA-HAPP-TA (sanded-top)spaced, staggered FiberRoofBoard plywoodH-Shield CG, Multi- centerrows MaxFA3 NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 10of83 N EMO|etc. TABLE1A:WOODDECKS–NEWCONSTRUCTION OR REROOF(T EAR-O FF) SYSTEMTYPEA-2:MECHANICALLYATTACHEDANCHORSHEET,BONDEDINSULATION,BONDEDROOFCOVER AnchorSheetBaseInsulationTopInsulationRoofCover(Note15) Deck SystemMDP FastenAttachAttachBase No.(psf) (Note1) TypeAttachTypeTypePlyCapPly Ply (Note11)(Notes6,7,8)(Notes6,7,8) 32ga.,1-5/8- 6-incho.c.in4-inchMin. 2-inch Polytherm,D-IS, OB500, Min.inch diameterD-IS, Elastobase,(Optional) Additional lap and 6-inch o.c.ACFoamII, III,CR-20orM- 19/32-tin caps withOB500,CR-APP-(Optional) W-27.Elastobase Pin four (4), equallylayers of baseAPP-TA-60.0* Polytherm H, H-Shield,OSFA, atop inch12ga.annular20orM-SA-HAPP-TA (sanded-top)spaced, staggeredH-Shield CG, Multi-fastener rows,insulation ring shank plywoodOSFA centerrowsMaxFA3orENRGY-37-incho.c. nails H YBRID S YSTEMSWITH S ELF-A DHERING SBSB ASE P LY: 9-inch o.c. at min.(Optional) Min. 1.5- Min.0.25-inchDens 2-inchlapand18-inch Polytherm, Min. Elastobase,Deck, Dens Deck Simplex MAXXinch o.c. at two,ACFoamII,ENRGY-3,SBS-SA-(Optional) 15/32- Prime,SECUROCK W-28.Elastobase PHotasphaltHotasphaltSBS-TA-45.0* inchCapequally spaced,Polytherm H, H-Shield,HSBS-TA (sanded-top)Gypsum-Fiber Roof plywoodstaggered centerH-Shield CG, Multi- Board rowsMaxFA3 9-inch o.c. at min.(Optional) Min. 1.5- Min.0.25-inchDens Min.2-inchlapand12-inch Polytherm, Elastobase,Deck, Dens Deck 15/32-Simplex MAXXinch o.c. at two,ACFoamII,ENRGY-3,SBS-SA-(Optional) W-29.Elastobase PHotasphaltPrime,SECUROCKHotasphaltSBS-TA-52.5 equally spaced,Polytherm H, H-Shield, inchCapHSBS-TA (sanded-top)Gypsum-Fiber Roof plywoodstaggered centerH-Shield CG, Multi- Board rowsMaxFA3 Polyglass G2 Base, (Optional) Min. 1.5- 32ga.,1-5/8-8-inch o.c. at min. Elastobase, Elastobase inch Polytherm,Min.0.25-inchDens Min.inch diameter4-inch lap and 8- P (sanded-top), ACFoam II, PolythermDeck, Dens Deck SBS-SA-(Optional) 19/32-tin caps withinch o.c. at three Elastovent, W-30.G,ACFoamIII,ENRGY-HotasphaltPrime,SECUROCKHotasphaltSBS-TA-60.0 CertainTeed Glasbase, inchHSBS-TA 11ga.annular(3),equallyspaced, 3, Polytherm H, H-Gypsum-Fiber Roof Firestone MB Base, JM plywoodring shankstaggered center Shield,H-ShieldCG,Board Perma-Ply28or nailsrows Multi-MaxFA3 GAFGLAS#75 12-inch o.c. at min.(Optional) Min. 1.5- Min.0.25-inchDens Min.4-inch lap and 12-inch Polytherm, Elastobase,Deck, Dens Deck Simplex MAXXSBS-SA-(Optional) 19/32-incho.c.attwo(2),ACFoamII,ENRGY-3, W-31.Elastobase PHotasphaltPrime,SECUROCKHotasphaltSBS-TA-60.0 CapFastenersequally spaced,Polytherm H, H-Shield,HSBS-TA inch (sanded-top)Gypsum-Fiber Roof plywoodstaggered centerH-Shield CG, Multi- Board rowsMaxFA3 NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 11of83 N EMO|etc. TABLE1A:WOODDECKS–NEWCONSTRUCTION OR REROOF(T EAR-O FF) SYSTEMTYPEA-2:MECHANICALLYATTACHEDANCHORSHEET,BONDEDINSULATION,BONDEDROOFCOVER AnchorSheetBaseInsulationTopInsulationRoofCover(Note15) Deck SystemMDP Base FastenAttachAttach No.(psf) (Note1) TypeAttachTypeTypePlyCapPly Ply (Note11)(Notes6,7,8)(Notes6,7,8) 32ga.,1-5/8-6-inch o.c. at min. Min. 2-inch Polytherm,D-IS, OB500, Min.inch diameter4-inch lap and 6-D-IS, Elastobase,ACFoamII, III,CR-20orM-(Optional) Additional SBS-SA-(Optional) 19/32-tin caps withincho.c.atfour(4),OB500,CR- W-32.Elastobase Players of baseSBS-TA-60.0* Polytherm H, H-Shield,OSFA, atop inch12ga.annularequally spaced,20orM-HSBS-TA (sanded-top)H-Shield CG, Multi-fastener rows,insulation plywoodring shankstaggered centerOSFA MaxFA3orENRGY-37-incho.c. nailsrows TABLE1B:WOODDECKS–NEWCONSTRUCTION,REROOF(T EAR-O FF)OR RECOVER SYSTEMTYPEA-2:MECHANICALLYATTACHEDANCHORSHEET,BONDEDINSULATION,BONDEDROOFCOVER AnchorSheetBaseInsulationTopInsulationRoofCover(Note15) Deck SystemMDP AttachAttach No. (psf) (Note1) TypeFasten(Note11)AttachTypeTypeBasePlyPlyCapPly (Notes(Notes 6,7,8)6,7,8) A SPHALT-A PPLIEDOR T ORCH-A PPLIED B ASE P LY: Dekfast Hex (aka, Dekfast PLT-H- Polyglass G210-inch o.c. in 4-(Optional) Min. 1.5- Min.0.25-inchDens 2-7/8) with Dekfast #14, OMG 3” Min.Base,inchlapand10-inchinch Polytherm,BP-AA,(Optional) Deck, Dens DeckSBS-AA, Round Metal Plate with OMG HotHot 15/32-Elastobase,o.c. in three (3),ACFoamII,ENRGY-3,SBS-AA,BP-AA, SBS- HD, OMG Flat Bottom Plate Prime,SECUROCK W-33.SBS-TA,-52.5 Elastobase PPolytherm H, H-Shield,asphaltasphaltSBS-TA,AA, SBS-TA, inchequally spaced, (Accutrac) with Roofgrip #14 or Gypsum-Fiber RoofAPP-TA plywood(sanded-top)staggered centerH-Shield CG, Multi-APP-TAAPP-TA Trufast3” Metal Insulation Plate Board orElastoventrowsMaxFA3 withTrufast#14HD. Min. 0.75-inch Fesco 12-inch o.c. in 4-(Optional) Min. 1.5- Board Min.Elastobase,inchlapand12-inchinch Polytherm, (homogeneous) or(Optional)SBS-AA, ACFoamII,ENRGY-3, 19/32-Elastobase POMG Flat Bottom Plateso.c. in two (2),HotHotBP-AA or W-34.min. 0.5-inchBP-AA orSBS-TA,-60.0 inch(sanded-top)(square)withRoofgrip#12equally spaced,Polytherm H, H-Shield,asphaltasphaltSBS-AA Structodek HighSBS-AAAPP-TA orElastovent plywoodstaggered centerH-Shield CG, Multi- Density Fiberboard rowsMaxFA3 RoofInsulation 12-inch o.c. in 4-(Optional) Min. 1.5- Min.0.25-inchDens Min.Elastobase,inchlapand12-inchinch Polytherm,BP-AA,(Optional) SBS-AA, Deck, Dens Deck OMG Flat Bottom Plateso.c. in two (2),ACFoamII,ENRGY-3,HotHot 19/32-Elastobase PSBS-AA,BP-AA, SBS- W-35.Prime,SECUROCKSBS-TA,-60.0 inch(sanded-top)(square)withRoofgrip#12equally spaced,Polytherm H, H-Shield,asphaltasphaltSBS-TA,AA, SBS-TA, Gypsum-Fiber RoofAPP-TA plywoodorElastoventstaggered centerAPP-TAAPP-TA H-Shield CG, Multi- Board rowsMaxFA3 NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 12of83 N EMO|etc. TABLE1B:WOODDECKS–NEWCONSTRUCTION,REROOF(T EAR-O FF)OR RECOVER SYSTEMTYPEA-2:MECHANICALLYATTACHEDANCHORSHEET,BONDEDINSULATION,BONDEDROOFCOVER AnchorSheetBaseInsulationTopInsulationRoofCover(Note15) Deck SystemMDP AttachAttach No.(psf) (Note1) TypeFasten(Note11)AttachTypeTypeBasePlyPlyCapPly (Notes(Notes 6,7,8)6,7,8) Dekfast Hex (aka, Dekfast PLT-H- Polyglass G2(Optional) Min. 1.5- 9-incho.c.in4-inchMin.0.25-inchDens 2-7/8) with Dekfast #14, OMG 3” Min.Base,inch Polytherm,BP-AA,(Optional) Deck, Dens Deck lap and 9-inch o.c.SBS-AA, Round Metal Plate with OMG 15/32-Elastobase,ACFoamII,ENRGY-3,HotHotSBS-AA,BP-AA, SBS- HD, OMG Flat Bottom Plate W-36.Prime,SECUROCKSBS-TA,-82.5 in four (4), equally inchElastobase PPolytherm H, H-Shield,asphaltasphaltSBS-TA,AA, SBS-TA, (Accutrac) with Roofgrip#14 or spaced, staggeredAPP-TA Gypsum-Fiber Roof plywood(sanded-top)H-Shield CG, Multi-APP-TAAPP-TA Trufast 3” Metal Insulation Plate centerrowsBoard orElastovent MaxFA3 withTrufast#14HD. S ELF-A DHERING B ASE P LY: 12-inch o.c. in 4-(Optional) Min. 1.5- Min.0.25-inchDens Min.Elastobase,inchlapand12-inchinch Polytherm,(Optional)SBS-SA, Deck, Dens Deck 19/32-Elastobase POMG Flat Bottom Plateso.c. in two (2),ACFoamII,ENRGY-3,HotHotSBS-SA,APP-SA, W-37.Prime,SECUROCKSBS-SA-60.0 inch(sanded-top)(square)withRoofgrip#12equally spaced,Polytherm H, H-Shield,asphaltasphaltSBS-TA,SBS-TA, Gypsum-Fiber Roof plywoodorElastoventstaggered centerH-Shield CG, Multi-APP-TAAPP-TA Board rowsMaxFA3 H YBRID S YSTEMSWITH S ELF-A DHERING APPB ASE P LY: Dekfast Hex (aka, Dekfast PLT-H- Polyglass G210-inch o.c. in 4-(Optional) Min. 1.5- Min.0.25-inchDens 2-7/8) with Dekfast#14, OMG 3” Min.Base,inchlapand10-inchinch Polytherm, Deck, Dens Deck Round Metal Plate with OMG 15/32-Elastobase,o.c. in three (3),ACFoamII,ENRGY-3,HotHot(Optional) HD, OMG Flat Bottom Plate W-38.Prime,SECUROCKAPP-SA-HAPP-TA-52.5 Polytherm H, H-Shield, inchElastobase Pequally spaced,asphaltasphaltAPP-TA (Accutrac) with Roofgrip #14 or Gypsum-Fiber Roof plywood(sanded-top)staggered centerH-Shield CG, Multi- Trufast 3” Metal Insulation Plate Board orElastoventrowsMaxFA3 withTrufast#14HD. 12-inch o.c. in 4-(Optional) Min. 1.5- Min.0.25-inchDens Min.Elastobase,inchlapand12-inchinch Polytherm, Deck, Dens Deck 19/32-Elastobase POMG Flat Bottom Plateso.c. in two (2),ACFoamII,ENRGY-3,HotHot(Optional) W-39.Prime,SECUROCKAPP-SA-HAPP-TA-60.0 inch(sanded-top)(square)withRoofgrip#12equally spaced,Polytherm H, H-Shield,asphaltasphaltAPP-TA Gypsum-Fiber Roof plywoodorElastoventstaggered centerH-Shield CG, Multi- Board rowsMaxFA3 Dekfast Hex (aka, Dekfast PLT-H- Polyglass G2(Optional) Min. 1.5- 9-incho.c.in4-inchMin.0.25-inchDens 2-7/8) with Dekfast #14, OMG 3” Min.Base,inch Polytherm, lap and 9-inch o.c.Deck, Dens Deck Round Metal Plate with OMG 15/32-Elastobase,ACFoamII,ENRGY-3,HotHot(Optional) HD, OMG Flat Bottom Plate W-40.Prime,SECUROCKAPP-SA-HAPP-TA-82.5 in four (4), equally inchElastobase PPolythermH, H-Shield,asphaltasphaltAPP-TA (Accutrac) with Roofgrip #14 or spaced, staggeredGypsum-Fiber Roof (sanded-top) plywoodH-Shield CG, Multi- Trufast 3” Metal Insulation Plate centerrowsBoard orElastoventMaxFA3 withTrufast#14HD. H YBRID S YSTEMSWITH S ELF-A DHERING SBSB ASE P LY: NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 13of83 N EMO|etc. TABLE1B:WOODDECKS–NEWCONSTRUCTION,REROOF(T EAR-O FF)OR RECOVER SYSTEMTYPEA-2:MECHANICALLYATTACHEDANCHORSHEET,BONDEDINSULATION,BONDEDROOFCOVER AnchorSheetBaseInsulationTopInsulationRoofCover(Note15) Deck SystemMDP AttachAttach No.(psf) (Note1) TypeFasten(Note11)AttachTypeTypeBasePlyPlyCapPly (Notes(Notes 6,7,8)6,7,8) 12-inch o.c. at min.(Optional) Min. 1.5- Min.0.25-inchDens Min.Elastobase,4-inch lap and 12-inch Polytherm, Deck, Dens Deck OMG Flat Bottom PlatesHotHot(Optional) 19/32-Elastobase Pincho.c.attwo(2),ACFoamII,ENRGY-3, Prime,SECUROCK W-41.SBS-SA-HSBS-TA-60.0 inch(sanded-top)(square)withRoofgrip#12equally spaced,Polytherm H, H-Shield,asphaltasphaltSBS-TA Gypsum-Fiber Roof plywoodorElastoventstaggered centerH-Shield CG, Multi- Board rowsMaxFA3 TABLE1C:WOODDECKS–NEWCONSTRUCTION,REROOF(T EAR-O FF)OR RECOVER SYSTEMTYPEB-1:MECHANICALLYATTACHEDBASEINSULATION,BONDEDTOPINSULATION,BONDEDROOFCOVER BaseInsulationLayerTopInsulationLayerRoofCover(Note15) SystemDeck (NoteMDP Attach No.1)(psf) TypeFasten(Note11)AttachTypeBasePlyPlyCapPly (Notes6,7,8) A SPHALT-A PPLIEDOR T ORCH-A PPLIED B ASE P LY Dekfast Hex (aka, Dekfast PLT-H-2-Min. 0.75-inch Fesco Board Min. 19/32-Min. 1.5-inch ENRGY(Optional if(Optional if using AASBS-AA, 7/8)withDekfast#12orTrufast3”1per(homogeneous) or min. 0.5-inch inch3, H-Shield orusing AA Ply)Base) BP-AA, SBS-AA,SBS-TA, W-42.Hotasphalt-60.0 2 Metal Insulation Plate with Trufast1.3ftStructodek High Density plywoodPolythermBP-AA,SBS-AASBS-TAorAPP-TAAPP-TA DPFiberboardRoofInsulation Min. 2-inch Dekfast #14 with Dekfast Hex (aka, Polytherm, ACFoam Min. 15/32-DekfastPLT-H-2-7/8),OMG#14HDMin. 0.25-inch Dens Deck PrimeSBS-AA, II,ENRGY-3,1perSBS-AA, SBS-(Optional) SBS-AA, SBS-TA, W-43.inchwithOMG3”GalvalumeSteelPlatesor SECUROCK Gypsum Fiber RoofHotasphalt-75.0 2 EnergyGuard Polyiso1.0ftTA,APP-TASBS-TA,APP-TA plywoodBoardAPP-TA or Trufast #14 HD with Trufast 3- Insulation, H-Shield inchInsulationPlates orMulti-MaxFA3 H YBRID S YSTEMSWITH S ELF-A DHERING APPB ASE P LY: Min. 2-inch Dekfast #14 with Dekfast Hex (aka, Polytherm, ACFoam Min. 15/32-DekfastPLT-H-2-7/8),OMG#14HDMin. 0.25-inch Dens Deck Prime 1per II,ENRGY-3, W-44.inchor SECUROCK Gypsum Fiber RoofHotasphaltAPP-SA-H(Optional)APP-TAAPP-TA-75.0 withOMG3”GalvalumeSteelPlates 2 EnergyGuard Polyiso 1.0ft plywoodor Trufast #14 HD with Trufast 3-Board Insulation, H-Shield inchInsulationPlates orMulti-MaxFA3 NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 14of83 N EMO|etc. TABLE1D:WOODDECKS–NEWCONSTRUCTION,REROOF(T EAR-O FF)OR RECOVER SYSTEMTYPEC-1:MECHANICALLYATTACHEDINSULATION,BONDEDROOFCOVER TopInsulationLayerRoofCover(Note15) Deck SystemBase InsulationMDP No.Layer(Note13) (psf) (Note1) TypeFasten(Note11)AttachBasePlyPlyCapPly A SPHALT-A PPLIEDOR T ORCH-A PPLIED B ASE P LY: (Optional)Oneor Min. 15/32-(Optional)SBS- Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8), more layers, anyMin. 0.25-inch Dens Deck Prime orSBS-AA, SBS-SBS-AA, SBS- 2 OMG #14 HD with OMG 3” Galvalume Steel Plates or inchAA, SBS-TA, W-45.1per1.8ft-45.0 combination,SECUROCKGypsum-FiberRoofBoardTA,APP-TATA,APP-TA Trufast#14HDwithTrufast3-inchInsulationPlates plywoodAPP-TA looselaid (Optional)Oneor Min. 15/32-(Optional)SBS- Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8), more layers, anyMin. 0.25-inch Dens Deck Prime orSBS-AA, SBS-SBS-AA, SBS- 2 OMG #14 HD with OMG 3” Galvalume Steel Plates or W-46.inch1per1.0ftAA, SBS-TA,-75.0 combination,SECUROCKGypsum-FiberRoofBoardTA,APP-TATA,APP-TA Trufast#14HDwithTrufast3-inchInsulationPlates plywoodAPP-TA looselaid Min.0.5-inchStructodekHighDensity(Optional if (Optional)Oneor(Optional if Min. 19/32-FiberboardRoofInsulationormin.using AA Base) more layers, anyusing AA Ply)SBS-AA, SBS- Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #12 2 W-47.inch0.25-inch Dens Deck, Dens Deck1per1.3ftBP-AA, SBS-AA,-82.5 DP BP-AA, SBS- combination,TA,APP-TA plywoodPrime or SECUROCK Gypsum-FiberSBS-TA or APP- looselaidAA RoofBoardTA S ELF-A DHERING B ASE P LY: Polygrip #14 with PolygripHex Plate or Dekfast #14 with DekfastHex(aka,DekfastPLT-H-2-7/8)orDekfast One or more Min. 15/32-Min. 0.25-inch SECUROCK Gypsum- Galvalume Steel 3” Round(aka,Dekfast PLT-R-3)or layers, any 2 OMG #14 Roofgrip with OMG 3 in. Round Metal Plate, W-48.inchFiber Roof Board optionally primed1per2.0ftSBS-SANoneSBS-SA-45.0 combination,min. OMG 3 in. Ribbed Galvalume Plate (Flat) or Accutrac Flat plywoodwithPOLYBRITE745orWB3000 1-inch,looselaid BottomPlateorTrufast#14HDFastenerswithTrufast 3”MetalInsulation Plate Polygrip #14 with Polygrip Hex Plate or Dekfast #14 with One or more Min. 15/32-Min. 0.25-inch Dens Deck Prime Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or OMG #14 layers, any 2 Roofgrip with OMG 3 in. Round Metal Plate or Accutrac W-49.inchoptionallyprimedwithPOLYBRITE1per2.0ftSBS-SANoneSBS-SA-45.0 combination,min. Flat Bottom Plate or Trufast#14 HD Fasteners with plywood745orWB3000 1-inch,looselaid Trufast3”MetalInsulation Plate Polygrip #14 with Polygrip Hex Plate or Dekfast DF-#14 One or more(Optional when Min. 15/32-Min. 0.25-inch SECUROCK Gypsum-SBS-SA, APP- with Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or OMG #14 -45.0 layers, anyusing torch- 2 Roofgrip with OMG 3 in. Round Metal Plate or Accutrac W-50.inchFiber Roof Board optionally primed1per1.8ftSBS-SASA, SBS-TA or combination,min.applied Cap Ply) Flat Bottom Plate or Trufast #14 HD Fastenerswith plywoodwithPOLYBRITE745orWB3000APP-TA 1-inch,looselaidSBS-TA,APP-TA Trufast3”MetalInsulation Plate One or more(Optional when Min. 15/32-Min. 0.25-inch Dens Deck PrimeSBS-SA, APP- OMG#14Roofgrip withOMG3in.RoundMetalPlateor layers, anyusing torch- 2 Trufast #14 HD Fasteners with Trufast 3” Metal W-51.inchoptionallyprimedwithPOLYBRITE1per1.8ftSBS-SASA, SBS-TA or-45.0 combination,min.applied Cap Ply) InsulationPlate plywood745orWB3000APP-TA 1-inch,looselaidSBS-TA,APP-TA NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 15of83 N EMO|etc. TABLE1D:WOODDECKS–NEWCONSTRUCTION,REROOF(T EAR-O FF)OR RECOVER SYSTEMTYPEC-1:MECHANICALLYATTACHEDINSULATION,BONDEDROOFCOVER TopInsulationLayerRoofCover(Note15) Deck SystemBase InsulationMDP No.Layer(Note13) (psf) (Note1) TypeFasten(Note11)AttachBasePlyPlyCapPly (Optional)Oneor Min. 15/32-Min. 0.25-inch Dens Deck Prime, Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8), more layers, any(Optional)SBS-SBS-TA, APP- 2 OMG #14 HD with OMG 3” Galvalume Steel Plates or W-52.inchDEXcell FA Glass Mat Roof Board or1per1.0ftSBS-SA-60.0 combination,TA,APP-TATA Trufast#14HDwithTrufast3-inchInsulationPlates plywoodSECUROCKGypsum-FiberRoofBoard looselaid Min. 1.5-inch ACFoam II, ACFoam III, EnergyGuard PolyisoInsulation, Min. 19/32-(Optional)Oneor ENRGY3,ENRGY3CGF,H-Shield,H-(Optional)SBS-SBS-SA, APP- Trufast Versa Fasteners (min. ¾” penetration) & Plates; inch APAmore layers, any 2 2 screws per plate installed 180° into theholes of the Shield CG, ISO 95+ GL, Multi-Max FA3,1per1.3ftSBS-SASA, SBS-TA,SA, SBS-TA,-67.5* ratedcombination, plate Polytherm or Ultra-Max optionallyAPP-TAAPP-TA W-53. plywoodlooselaid primed with POLYBRITE 745 or WB3000 Note:*For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 180 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce Minimum CharacteristicResistance Force(MCRF) Min. 1.5-inch ACFoam II, ACFoam III, DekfastHex(aka,DekfastPLT-H-2-7/8)orDekfast EnergyGuard Polyiso Insulation, Galvalume Steel 3” Round Insulation Plate (aka, Dekfast (Optional)OneorENRGY3,ENRGY3CGF,H-Shield,H- PLT-R-3) with Dekfast #12, OMG 3 in. Galvalume Plate Min. 19/32-(Optional)SBS-SBS-SA, APP- more layers, anyShield CG, ISO 95+ GL, Multi-Max FA3, (non-ribbed) or OMG AccuTrac Plate with #12 Roofgrip 2 W-54.inch1per1.3ftSBS-SASA, SBS-TA,SA, SBS-TA,-67.5* or Trufast 3” Metal Insulation Plate with Trufast combination,Polytherm or Ultra-Max optionally plywoodAPP-TAAPP-TA DPDekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast looselaidprimed with POLYBRITE 745 or #12 DP or Trufast 3” Metal Insulation Plate with Trufast WB3000ENRGY 3, H-Shield or DP Polytherm H YBRID S YSTEMSWITH S ELF-A DHERING APPB ASE P LY: (Optional)Oneor Min. 15/32- Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8), more layers, anyMin. 0.25-inch Dens Deck Prime or(Optional) APP- 2 OMG #14 HD with OMG 3” Galvalume Steel Plates or inch W-55.1per1.8ftAPP-SA-HAPP-TA-45.0 combination,SECUROCKGypsum-FiberRoofBoardTA Trufast#14HDwithTrufast3-inchInsulationPlates plywood looselaid H YBRID S YSTEMSWITH S ELF-A DHERING SBSB ASE P LY: Polygrip #14 with Polygrip Hex Plate or Dekfast #14 with DekfastHex(aka,DekfastPLT-H-2-7/8)orDekfast One or more Min. 15/32-Min. 0.25-inch SECUROCK Gypsum- Galvalume Steel 3” Round(aka,Dekfast PLT-R-3)or (Optional)SBS- layers, any 2 OMG #14 Roofgrip with OMG 3 in. Round Metal Plate, W-56.inchFiber Roof Board optionally primed1per2.0ftSBS-SA-HSBS-TA-45.0 combination,min.TA OMG 3 in. Ribbed Galvalume Plate (Flat) or Accutrac Flat plywoodwithPOLYBRITE745orWB3000 1-inch,looselaid BottomPlateorTrufast#14HD FastenerswithTrufast 3”MetalInsulation Plate Polygrip#14 with Polygrip Hex Plate or Dekfast #14 with One or more Min. 15/32-Min. 0.25-inch Dens Deck Prime Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or OMG #14 layers, any(Optional)SBS- 2 Roofgrip with OMG 3 in. Round Metal Plate or Accutrac W-57.inchoptionallyprimedwithPOLYBRITE1per2.0ftSBS-SA-HSBS-TA-45.0 combination,min.TA Flat Bottom Plate or Trufast #14 HD Fasteners with plywood745orWB3000 1-inch,looselaid Trufast3”MetalInsulation Plate NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 16of83 N EMO|etc. TABLE 1D: WOOD DECKS –NEW CONSTRUCTION, REROOF (T EAR-O FF) OR RECOVER SYSTEMTYPEC-1:MECHANICALLYATTACHEDINSULATION,BONDEDROOFCOVER TopInsulationLayerRoofCover(Note15) Deck SystemBase InsulationMDP No.Layer(Note13) (psf) (Note1) TypeFasten(Note11)AttachBasePlyPlyCapPly (Optional)Oneor Min. 15/32-Min. 0.25-inch Dens Deck Prime, Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8), more layers, any(Optional)SBS- 2 OMG #14 HD with OMG 3” Galvalume Steel Plates or W-58.inch1per1.0ftSBS-SA-HSBS-TA-60.0 DEXcell FA Glass Mat Roof Board or combination,TA Trufast#14HDwithTrufast3-inchInsulationPlates plywoodSECUROCKGypsum-FiberRoofBoard looselaid Min. 1.5-inch ACFoam II, ACFoam III, EnergyGuard Polyiso Insulation, (Optional)Oneor Min. 19/32”ENRGY3,ENRGY3CGF,H-Shield,H- Trufast Versa Fasteners (min. ¾” penetration) & Plates; more layers, any(Optional)SBS- 2 2 screws per plate installed 180° into the holes of the W-59.1per1.3ftSBS-SA-HSBS-TA-67.5* APA ratedShield CG, ISO 95+ GL, Multi-Max FA3, combination,TA plate* plywoodPolytherm or Ultra-Max optionally looselaid primed with POLYBRITE 745 or WB3000 Note:*For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 180 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to W-60. produce minimum withdrawalresistance Min. 1.5-inch ACFoam II, ACFoam III, EnergyGuard Polyiso Insulation, DekfastHex(aka,DekfastPLT-H-2-7/8)orDekfast (Optional)Oneor Min. 19/32-ENRGY3,ENRGY3CGF,H-Shield,H- Galvalume Steel 3” Round Insulation Plate (aka, Dekfast more layers, any(Optional)SBS- 2 PLT-R-3) with Dekfast#12, OMG 3 in. Galvalume Plate W-61.inchShield CG, ISO 95+ GL, Multi-Max FA3,1per1.3ftSBS-SA-HSBS-TA-67.5* combination,TA (non-ribbed) or OMG AccuTrac Plate with #12 Roofgrip plywoodPolytherm or Ultra-Max optionally looselaid orTrufast3”MetalInsulation PlatewithTrufastDP primed with POLYBRITE 745 or WB3000 TABLE 1E: WOOD DECKS –NEW CONSTRUCTION, REROOF (T EAR-O FF) OR RECOVER SYSTEMTYPED-2:INSULATED,MECHANICALLYATTACHEDBASESHEET,BONDEDROOFCOVER Insulation Layer(s) BaseSheetRoofCover(Note15) SystemMDP (Note13) Deck(Note1) No. (psf) TypeAttachTypeFasten(Note11)AttachBasePlyCapPly A SPHALT-A PPLIEDOR T ORCH-A PPLIED B ASE P LY: Elastobase, Elastobase P, OMG Flat BottomPlates (square)with OneormoreElastovent, PolyglassG2 Base,12-incho.c.in4-inchlapand12-(Optional) BP- Min.19/32-inchPrelim.SBS-AA, SBS- Roofgrip #14, Dekfast Hex (aka, Dekfast PLT-H- W-62.-52.5 layers, anyCertainTeed Glasbase,inch o.c. in two (2), equallyAA,SBS-AA,SBS- 2-7/8) with Dekfast #14 or Trufast 3” Metal plywoodAttachedTA,APP-TA combinationFirestoneMBBase,JMPerma-spaced,staggeredcenterrowsTAorAPP-TA InsulationPlatewith Trufast#14HD Ply28orGAFGLAS#75 Oneormore12-incho.c.in4-inchlapand12-(Optional) BP- Min.19/32-inchPrelim.Elastobase,ElastobasePorSBS-AA, SBS- OMG Flat Bottom Plates (square) with W-63.layers, anyinch o.c. in two (2), equallyAA,SBS-AA,SBS--60.0 Roofgrip#12 plywoodAttachedElastoventTA,APP-TA combinationspaced,staggeredcenterrowsTAorAPP-TA NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 17of83 N EMO|etc. TABLE1E:WOODDECKS–NEWCONSTRUCTION,REROOF(T EAR-O FF)OR RECOVER SYSTEMTYPED-2:INSULATED,MECHANICALLYATTACHEDBASESHEET,BONDEDROOFCOVER InsulationLayer(s) BaseSheetRoofCover(Note15) SystemMDP (Note13) Deck(Note1) No.(psf) TypeAttachTypeFasten(Note11)AttachBasePlyCapPly SBS-SA, APP- TrufastVersa Fasteners (min. ¾” penetration) Min.19/32-inchOneormore12-inch o.c. at min. 4-inch lap and Elastobase,ElastobasePorBP-AA, SBS-AA,SA, SBS-AA, & Plates; 2 screws per plate installed 180° into APA ratedlayers, anyLoose-laid12-inch o.c. at two (2), equally-67.5 the holes of the plate, parallel to the width- ElastoventSBS-TA,APP-TASBS-TA, APP- plywoodcombinationspaced,staggeredcenterrows W-64. directionof thesheet* TA *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 199 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to Note: produceMinimum CharacteristicResistance Force(MCRF) TrufastVersa Fasteners (min. ¾” penetration) 12-inch o.c. at min. 4-inch lap and Min.19/32-inchOneormore & Plates; 2 screws per plate installed 180° into APA ratedlayers, anyLoose-laidPolyglassBase12-inch o.c. at two (2), equallyAPP-TAAPP-TA-67.5 the holes of the plate, parallel to the width- plywoodcombinationspaced,staggeredcenterrows W-65. directionof thesheet* Note:*For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 199 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produceMinimum CharacteristicResistance Force(MCRF) Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Oneormore10-incho.c.in4-inchlapand10-(Optional) BP- Dekfast#14, OMG 3” Round Metal Plate with Min.15/32-inchPrelim.PolyglassG2Base,Elastobase,SBS-AA, SBS- OMG HD, OMG Flat Bottom Plate (Accutrac) W-66.layers, anyinch o.c. in three (3), equallyAA,SBS-AA,SBS--75.0 plywoodAttachedElastobasePorElastoventTA,APP-TA with Roofgrip #14 or Trufast 3” Metal combinationspaced,staggeredcenterrowsTAorAPP-TA InsulationPlatewith Trufast#14HD. Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Oneormore10-incho.c.in4-inchlapand10- Dekfast#14, OMG 3” Round Metal Plate with Min.15/32-inchPrelim.(Optional)APP- OMG HD, OMG Flat Bottom Plate (Accutrac) W-67.layers, anyPolyglassBaseinch o.c. in three (3), equallyAPP-TA-75.0 plywoodAttachedTA with Roofgrip #14 or Trufast 3” Metal combinationspaced,staggeredcenterrows InsulationPlatewith Trufast#14HD. Min.15/32-inch SBS-SA, APP- TrufastVersa Fasteners (min. ¾” penetration) (existing) orOneormore9-incho.c.atmin.2-inchlapand Elastobase,ElastobasePorBP-AA, SBS-AA,SA, SBS-AA, & Plates; 2 screws per plate installed 180° into min. 19/32-inchlayers, anyLoose-laid12-inch o.c. at two (2), equally-90.0 the holes of the plate, parallel to the width- ElastoventSBS-TA,APP-TASBS-TA, APP- (new)APAcombinationspaced,staggeredcenterrows W-68. directionof thesheet* TA ratedplywood Note:*For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 159 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produceMinimum CharacteristicResistance Force(MCRF) Min.15/32-inch Trufast Versa Fasteners (min. ¾” penetration) (existing) orOneormore9-incho.c.atmin.2-inchlapand & Plates; 2 screws per plate installed 180° into min. 19/32-inchlayers, anyLoose-laidPolyglassBase12-inch o.c. at two (2), equallyAPP-TAAPP-TA-90.0 the holes of the plate, parallel to the width- (new)APAcombinationspaced,staggeredcenterrows W-69. directionof thesheet* ratedplywood Note:*For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 159 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produceMinimum CharacteristicResistance Force(MCRF) NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 18of83 N EMO|etc. TABLE1E:WOODDECKS–NEWCONSTRUCTION,REROOF(T EAR-O FF)OR RECOVER SYSTEMTYPED-2:INSULATED,MECHANICALLYATTACHEDBASESHEET,BONDEDROOFCOVER InsulationLayer(s) BaseSheetRoofCover(Note15) SystemMDP (Note13) Deck(Note1) No.(psf) TypeAttachTypeFasten(Note11)AttachBasePlyCapPly Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Oneormore9-inch o.c. in 4-inch lap and 9-(Optional) BP- Dekfast #14, OMG 3” Round Metal Plate with Min.15/32-inchPrelim.PolyglassG2Base,Elastobase,SBS-AA, SBS- OMG HD, OMG Flat Bottom Plate (Accutrac) W-70.layers, anyinch o.c. in four (4), equallyAA,SBS-AA,SBS--90.0 plywoodAttachedElastobasePorElastoventTA,APP-TA with Roofgrip #14 or Trufast 3” Metal combinationspaced,staggeredcenterrowsTAorAPP-TA InsulationPlatewith Trufast#14HD. Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Oneormore9-inch o.c. in 4-inch lap and 9- Dekfast #14, OMG 3” Round Metal Plate with Min.15/32-inchPrelim.(Optional)APP- OMG HD, OMG Flat Bottom Plate (Accutrac) W-71.PolyglassBaseAPP-TA-90.0 layers, anyinch o.c. in four (4), equally plywoodAttachedTA with Roofgrip #14 or Trufast 3” Metal combinationspaced,staggeredcenterrows InsulationPlatewith Trufast#14HD. Oneormore6-inch o.c. at 4-inch lap and 6- Min.15/32-inchPrelim.Elastobase,ElastobasePor(Optional)BP-AA Trufast#12DPorTrufast#14HDwithTrufast layers, anyinch o.c. in three (3), equally W-72.SBS-AA-90.0 3”MetalInsulationPlates plywood AttachedElastoventorSBS-AA combinationspaced,staggeredcenterrows Oneormore6-inch o.c. at 4-inch lap and 6-(Optional) BP- OMG #12 Standard Roofgrip or OMG #14 Min.15/32-inchPrelim.Elastobase,ElastobasePorSBS-AA, SBS- Heavy Duty with OMG 3” Round Metal Plates layers, anyinch o.c. in three (3), equallyAA,SBS-AA,SBS- W-73.-90.0 plywoodAttachedElastoventTAorAPP-TA orOMG FlatBottomMetalPlates combinationspaced,staggeredcenterrowsTA,APP-TA Oneormore6-inch o.c. at 4-inch lap and 6- OMG #12 Standard Roofgrip or OMG #14 Min.15/32-inchPrelim.(Optional)APP- Heavy Duty with OMG 3” Round Metal Plates layers, anyinch o.c. in three (3), equally W-74.PolyglassBaseAPP-TA-90.0 plywoodAttachedTA orOMG Flat BottomMetalPlates combinationspaced,staggeredcenterrows Min.15/32-inch SBS-SA, APP- Trufast Versa Fasteners (min. ¾” penetration) (existing) orOneormore6-incho.c.atmin.4-inchlapand Elastobase,ElastobasePorBP-AA, SBS-AA,SA, SBS-AA, & Plates; 2 screws per plate installed 180° into min. 19/32-inchlayers, anyLoose-laid6-inch o.c. at three (3), equally-105.0 the holes of the plate, parallel to the width- ElastoventSBS-TA,APP-TASBS-TA, APP- (new)APAcombinationspaced,staggeredcenterrows W-75. directionof thesheet* TA ratedplywood Note:*For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 103 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produceMinimum CharacteristicResistance Force(MCRF) Min.15/32-inch Trufast Versa Fasteners (min. ¾” penetration) (existing) or Oneormore6-incho.c.atmin.4-inchlapand & Plates; 2 screws per plate installed 180° into Loose-laidPolyglassBaseAPP-TAAPP-TA-105.0 min. 19/32-inchlayers, any6-inch o.c. at three (3), equally the holes of the plate, parallel to the width- (new)APAcombinationspaced,staggeredcenterrows W-76. directionof thesheet* ratedplywood Note:*For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 103 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produceMinimum CharacteristicResistance Force(MCRF) Oneormore6-inch o.c. at 4-inch lap and 6- Min.15/32-inchPrelim.Elastobase,ElastobasePor(Optional)BP-AA Trufast#12DPorTrufast#14HDwithTrufast W-77.layers, anyinch o.c. in five (5), equallySBS-AA-120.0 3”MetalInsulationPlates plywood AttachedElastoventorSBS-AA combinationspaced,staggeredcenterrows NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 19of83 N EMO|etc. TABLE1E:WOODDECKS–NEWCONSTRUCTION,REROOF(T EAR-O FF)OR RECOVER SYSTEMTYPED-2:INSULATED,MECHANICALLYATTACHEDBASESHEET,BONDEDROOFCOVER InsulationLayer(s) BaseSheetRoofCover(Note15) SystemMDP (Note13) Deck(Note1) No.(psf) TypeAttachTypeFasten(Note11)AttachBasePlyCapPly Oneormore6-inch o.c. at 4-inch lap and 6-(Optional) BP- OMG #12 Standard Roofgrip or OMG #14 Min.15/32-inchPrelim.Elastobase,ElastobasePorSBS-AA, SBS- Heavy Duty with OMG 3” Round Metal Plates W-78.layers, anyinch o.c. in five (5), equallyAA,SBS-AA,SBS--120.0 plywood AttachedElastoventTAorAPP-TA orOMG FlatBottomMetalPlates combinationspaced,staggeredcenterrowsTA,APP-TA Oneormore6-inch o.c. at 4-inch lap and 6- OMG #12 Standard Roofgrip or OMG #14 Min.15/32-inchPrelim.(Optional)APP- Heavy Duty with OMG 3” Round Metal Plates layers, anyinch o.c. in five (5), equally W-79.PolyglassBaseAPP-TA-120.0 plywoodAttachedTA orOMG FlatBottomMetalPlates combinationspaced,staggeredcenterrows S ELF-A DHERING B ASE P LY: Oneormore12-inch o.c. in 4-inch lap and 12-SBS-SA, APP- Dekfast Hex (aka, DekfastPLT-H-2-7/8) with Min.19/32-inchPrelim.Elastobase,ElastobaseP(poly- Dekfast #14 or Trufast 3” Metal Insulation W-80.layers, anyinch o.c. in two, equally spaced,SBS-SASA, SBS-TA-52.5* plywood Attachedfilmtop) Platewith Trufast#14HD combinationstaggeredcenterrowsorAPP-TA Oneormore12-inch o.c. in 4-inch lap and 12-SBS-SA, APP- Min.19/32-inchPrelim.Elastobase,ElastobaseP(poly- OMG Flat Bottom Plates (square) with layers, anyinch o.c.in two, equally spaced,SA, SBS-TA W-81.SBS-SA-60.0* Roofgrip#12 plywoodAttachedfilmtop) combinationstaggeredcenterrowsorAPP-TA TrufastVersa Fasteners (min. ¾” penetration) 12-inch o.c. at min. 4-inch lap andSBS-SA, APP- Min.19/32-inchOneormore Elastobase,ElastobaseP(poly- & Plates; 2 screws per plate installed 180° into APA ratedlayers, anyLoose-laid12-inch o.c. at two (2), equallySBS-SASA, SBS-TA,-67.5 the holes of the plate, parallel to the width- filmtop) plywoodcombinationspaced,staggeredcenterrowsAPP-TA W-82. directionof thesheet* Note:*For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 199 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produceMinimum CharacteristicResistance Force(MCRF) H YBRID S YSTEMSWITH S ELF-A DHERING APPB ASE P LY: Oneormore12-inch o.c. in 4-inch lap and 12- Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Min.19/32-inchPrelim.Elastobase,ElastobaseP(poly- Dekfast #14 or Trufast 3” Metal Insulation layers, anyinch o.c. in two, equally spaced, W-83.APP-SA-HAPP-TA-52.5* plywood Attachedfilmtop) Platewith Trufast#14HD combinationstaggeredcenterrows Oneormore12-inch o.c. in 4-inch lap and 12- Min.19/32-inchPrelim.Elastobase,ElastobaseP(poly- OMG Flat Bottom Plates (square) with W-84.layers, anyinch o.c.in two, equally spaced,APP-SA-HAPP-TA-60.0* Roofgrip#12 plywoodAttachedfilmtop) combinationstaggeredcenterrows TrufastVersa Fasteners (min. ¾” penetration) Min.19/32-inchOneormore12-inch o.c. at min. 4-inch lap and Elastobase,ElastobaseP(poly- & Plates; 2 screws per plate installed 180° into Loose-laidAPP-SA-HAPP-TA-67.5 APA ratedlayers, any12-inch o.c. at two (2), equally the holes of the plate, parallel to the width- filmtop) plywoodcombinationspaced,staggeredcenterrows W-85. directionof thesheet* Note:*For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 199 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produceMinimum CharacteristicResistance Force(MCRF) H YBRID S YSTEMSWITH S ELF-A DHERING SBSB ASE P LY: Oneormore12-inch o.c. at min. 4-inch lap and Dekfast Hex (aka, DekfastPLT-H-2-7/8) with Min.19/32-inchPrelim.Elastobase,ElastobaseP(poly- Dekfast #14 or Trufast 3” Metal Insulation layers, any12-inch o.c. at two, equally W-86.SBS-SA-HSBS-TA-52.5* plywoodAttachedfilmtop) Platewith Trufast#14HD combinationspaced,staggeredcenterrows NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 20of83 N EMO|etc. TABLE 1E: WOOD DECKS –NEW CONSTRUCTION, REROOF (T EAR-O FF) OR RECOVER SYSTEMTYPED-2:INSULATED,MECHANICALLYATTACHEDBASESHEET,BONDEDROOFCOVER InsulationLayer(s) BaseSheetRoofCover(Note15) SystemMDP (Note13) Deck(Note1) No.(psf) TypeAttachTypeFasten(Note11)AttachBasePlyCapPly Oneormore12-inch o.c.at min. 4-inch lap and Min.19/32-inchPrelim.Elastobase,ElastobaseP(poly- OMG Flat Bottom Plates (square) with W-87.layers, any12-inch o.c. at two, equallySBS-SA-HSBS-TA-60.0* Roofgrip#12 plywood Attachedfilmtop) combinationspaced,staggeredcenterrows Trufast Versa Fasteners (min. ¾” penetration) Min.19/32-inchOneormore12-inch o.c. at min. 4-inch lap and Elastobase,ElastobaseP(poly- & Plates; 2 screws per plate installed 180° into APA ratedlayers, anyLoose-laid12-inch o.c. at two (2), equallySBS-SA-HSBS-TA-67.5 theholesof theplate,parallelto thewidth- filmtop) plywoodcombinationspaced,staggered centerrows W-88. directionofthesheet* *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 199 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to Note: produceMinimum CharacteristicResistance Force(MCRF) TABLE1F:WOODDECKS–NEWCONSTRUCTION OR REROOF(T EAR-O FF) SYSTEMTYPEE-2:NON-INSULATED,MECHANICALLYATTACHEDBASESHEET(NAILS),BONDEDROOFCOVER BaseSheetRoofCover(Note15) SystemMDP Deck(Note1) No. (psf) TypeFasten(Note11)AttachBasePlyCapPly N O B ASE P LY: 9-inch o.c. at 2-inch lap and 18-inch o.c. in twoSBS-AA, SBS-TA, W-89.Min.15/32-inchplywoodElastobase,ElastobasePSimplexMAXXCapNone-45.0* (2),equallyspaced,staggeredcenterrowsAPP-TA 9-inch o.c. at 2-inch lap and 12-inch o.c. in twoSBS-AA, SBS-TA, W-90.Min.15/32-inchplywoodElastobase,ElastobasePSimplexMAXXCapNone -52.5 (2),equallyspaced,staggeredcenterrowsAPP-TA Min. 15/32-inch 8-incho.c.atmin.3-inchlapand8-incho.c.at SBS-AA, SBS-TA, (existing)ormin.19/32- W-91.Elastobase(sandedtop)SimplexMAXXCapthree (3), equally spaced, staggered centerNone-60.0 inch (new) APA ratedAPP-TA rows plywood Min. 15/32-inch 8-incho.c.atmin.3-inchlapand8-incho.c.at (existing)ormin.19/32- W-92.Elastobase(poly-filmtop)SimplexMAXXCapthree (3), equally spaced, staggered centerNoneSBS-TA,APP-TA-60.0 inch (new) APA rated rows plywood Min. 15/32-inch 8-incho.c.atmin.3-inchlapand8-incho.c.at (existing)ormin.19/32- W-93.PolyglassBaseSimplexMAXXCapthree (3), equally spaced, staggered centerNoneAPP-TA-60.0 inch (new) APA rated rows plywood Min. 15/32-inch SimplexMAXXCap 8-incho.c.atmin.3-inchlapand8-incho.c.at (existing)ormin.19/32- W-94.Elastobase(poly-filmtop)three (3), equally spaced, staggered centerNoneSBS-SA,APP-SA-60.0 Note:MAXXCapsaretobeprimedwith inch (new) APA rated rows PG100orASTMD41primer plywood NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 21of83 N EMO|etc. TABLE1F:WOODDECKS–NEWCONSTRUCTION OR REROOF(T EAR-O FF) SYSTEMTYPEE-2:NON-INSULATED,MECHANICALLYATTACHEDBASESHEET(NAILS),BONDEDROOFCOVER BaseSheetRoofCover(Note15) SystemMDP Deck(Note1) No. (psf) TypeFasten(Note11)AttachBasePlyCapPly Elastobase, Elastobase P, Elastovent,Polyglass G2 Base, CertainTeed Glasbase,32 ga., 1-5/8-inch diameter tin caps with8-incho.c.in4-inchlapand8-incho.c.inthreeSBS-AA, SBS-TA, W-95.Min.19/32-inchplywoodNone-60.0 Firestone MB Base, JM11ga.annularring shanknails(3),equallyspaced,staggeredcenterrowsAPP-TA Perma-Ply 28 or GAFGLAS #75 Elastobase,ElastobaseP32 ga., 1-5/8-inch diameter tin caps with8-incho.c.in4-inchlapand8-incho.c.inthree W-96.Min.19/32-inchplywoodNoneSBS-SA,APP-SA-60.0 (poly-filmtop)11ga.annularring shanknails(3),equallyspaced,staggeredcenterrows Polyglass G2 Base, 32 ga., 1-5/8-inch diameter tin caps with8-inch o.c. in 4-inch lap and 8-inch o.c. in fourSBS-AA, SBS-TA, Elastobase,ElastobasePor W-97.Min.15/32-inchplywoodNone-67.5 11ga.annularring shanknails(4),equallyspaced,staggeredcenterrowsAPP-TA Elastovent 32 ga., 1-5/8-inch diameter tin caps with8-inch o.c. in 4-inch lap and 8-inch o.c. in four W-98.Min.15/32-inchplywoodPolyglassBaseNoneAPP-TA-67.5 11ga.annularring shanknails(4),equallyspaced,staggeredcenterrows 10-inch o.c. in 4-inch lap and 10-inch o.c. in Polyglass G2 Base,SBS-AA, SBS-TA, three (3), equally spaced, staggered center W-99.Min.15/32-inchplywoodSimplexMAXXCapNone-75.0 Elastobase,ElastobasePAPP-TA rows 10-inch o.c. in 4-inch lap and 10-inch o.c. in W-100.Min.15/32-inchplywoodPolyglassBaseSimplexMAXXCapthree (3), equally spaced, staggered centerNoneAPP-TA-75.0 rows Polyglass G2 Base,9-inch o.c. in 4-inch lap and 9-inch o.c. in fourSBS-AA, SBS-TA, W-101.Min.15/32-inchplywoodSimplexMAXXCapNone-90.0 Elastobase,ElastobaseP(4),equallyspaced,staggeredcenterrowsAPP-TA 9-inch o.c.in 4-inch lap and 9-inch o.c. in four W-102.Min.15/32-inchplywoodPolyglassBaseSimplexMAXXCapNoneAPP-TA-90.0 (4),equallyspaced,staggeredcenterrows 6-inch o.c. at 2-inch lap and 6-inch o.c. in twoSBS-AA, SBS-TA, W-103.Min.15/32-inchplywoodElastobase,ElastobasePSimplexMAXXCapNone-90.0 (2),equallyspaced,staggeredcenterrowsAPP-TA Elastobase,ElastobaseP32 ga., 1-5/8-inch diameter tin caps with4-inch o.c.in 4-inch lap and 4-inch o.c. in four W-104.Min.19/32-inchplywoodNoneSBS-SA,APP-SA-97.5 (poly-filmtop)11ga.annularringshanknails.(4),equallyspaced,staggeredcenterrows 6-inch o.c. at 2-inch lap and 6-inch o.c. in threeSBS-AA, SBS-TA, W-105.Min.15/32-inchplywoodElastobase,ElastobasePSimplexMAXXCapNone-105.0 (3),equallyspaced,staggeredcenterrowsAPP-TA Elastobase,ElastobasePor32 ga., 1-5/8-inch diameter tin caps with6-inch o.c.in 4-inch lap and 6-inch o.c. in fourSBS-AA, SBS-TA, W-106.Min.19/32-inchplywoodNone-112.5 Elastovent11ga.annularring shanknails(4),equallyspaced,staggeredcenterrowsAPP-TA 32 ga., 1-5/8-inch diameter tin caps with Elastobase,ElastobaseP11 ga.annular ring shank nails.Note: Tin 6-inch o.c. in 4-inch lap and 6-inch o.c. in four W-107.Min.19/32-inchplywoodNoneSBS-SA,APP-SA-112.5 (poly-filmtop)caps are to be primed with PG100 or(4),equallyspaced,staggeredcenterrows ASTMD41primer. A SPHALT-A PPLIEDOR T ORCH-A PPLIED B ASE P LY: NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 22of83 N EMO|etc. TABLE1F:WOODDECKS–NEWCONSTRUCTION OR REROOF(T EAR-O FF) SYSTEMTYPEE-2:NON-INSULATED,MECHANICALLYATTACHEDBASESHEET(NAILS),BONDEDROOFCOVER BaseSheetRoofCover(Note15) SystemMDP Deck(Note1) No. (psf) TypeFasten(Note11)AttachBasePlyCapPly SBS-SA, APP-SA, 9-inch o.c. at 2-inch lap and 18-inch o.c. in twoBP-AA, SBS-AA, SBS- SBS-AA, SBS-TA, W-108.Min.15/32-inchplywoodElastobase,ElastobasePSimplexMAXXCap-45.0* (2),equallyspaced,staggeredcenterrowsTA,APP-TA APP-TA SBS-SA, APP-SA, 9-inch o.c. at 2-inch lap and 12-inch o.c. in twoBP-AA, SBS-AA, SBS- SBS-AA, SBS-TA, W-109.Min.15/32-inchplywoodElastobase,ElastobasePSimplexMAXXCap-52.5 (2),equallyspaced,staggeredcenterrowsTA,APP-TA APP-TA Min. 15/32-inch 8-incho.c.atmin.3-inchlapand8-incho.c.at (existing)ormin.19/32-BP-AA, SBS-AA, SBS-SBS-AA, SBS-TA, W-110.Elastobase(sandedtop)SimplexMAXXCapthree (3), equally spaced, staggered center-60.0 inch (new) APA ratedTA,APP-TAAPP-TA rows plywood Min. 15/32-inch 8-incho.c.atmin.3-inchlapand8-incho.c.at (existing)ormin.19/32- three (3), equally spaced, staggered center W-111.Elastobase(poly-filmtop)SimplexMAXXCapSBS-TASBS-TA,APP-TA-60.0 inch (new) APA rated rows plywood Min. 15/32-inch 8-incho.c.atmin.3-inchlapand8-incho.c.at (existing)ormin.19/32- three (3), equally spaced, staggered center W-112.PolyglassBaseSimplexMAXXCapAPP-TAAPP-TA-60.0 inch (new) APA rated rows plywood Elastobase, Elastobase P, Elastovent, Polyglass G2 SBS-SA, APP-SA, Base,CertainTeedGlasbase,32 ga., 1-5/8-inch diameter tin caps with8-incho.c.in4-inchlapand8-incho.c.inthreeBP-AA, SBS-AA, SBS- W-113.Min.19/32-inchplywood-60.0 SBS-AA, SBS-TA, Firestone MB Base, JM11ga.annularring shanknails(3),equallyspaced,staggeredcenterrowsTA,APP-TA APP-TA Perma-Ply 28 or GAFGLAS #75 Polyglass G2 Base,SBS-SA, APP-SA, 32 ga., 1-5/8-inch diameter tin caps with8-inch o.c. in 4-inch lap and 8-inch o.c. in fourBP-AA, SBS-AA, SBS- W-114.Min.15/32-inchplywoodElastobase,ElastobasePorSBS-AA, SBS-TA,-67.5 11ga.annularring shanknails(4),equallyspaced,staggeredcenterrowsTA,APP-TA ElastoventAPP-TA 32 ga., 1-5/8-inch diameter tin caps with8-inch o.c.in 4-inch lap and 8-inch o.c. in four W-115.Min.15/32-inchplywoodPolyglassBaseAPP-TAAPP-TA-67.5 11ga.annularring shanknails(4),equallyspaced,staggeredcenterrows 10-inch o.c.in 4-inch lap and 10-inch o.c. inSBS-SA, APP-SA, Polyglass G2 Base,BP-AA, SBS-AA, SBS- W-116.Min.15/32-inchplywoodSimplexMAXXCapthree (3), equally spaced, staggered centerSBS-AA, SBS-TA,-75.0 Elastobase,ElastobaseP TA,APP-TA rowsAPP-TA 10-inch o.c.in 4-inch lap and 10-inch o.c. in three (3), equally spaced, staggered center W-117.Min.15/32-inchplywoodPolyglassBaseSimplexMAXXCapAPP-TAAPP-TA-75.0 rows NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 23of83 N EMO|etc. TABLE1F:WOODDECKS–NEWCONSTRUCTION OR REROOF(T EAR-O FF) SYSTEMTYPEE-2:NON-INSULATED,MECHANICALLYATTACHEDBASESHEET(NAILS),BONDEDROOFCOVER BaseSheetRoofCover(Note15) SystemMDP Deck(Note1) No. (psf) TypeFasten(Note11)AttachBasePlyCapPly SBS-SA, APP-SA, Polyglass G2 Base,9-inch o.c.in 4-inch lap and 9-inch o.c. in fourBP-AA, SBS-AA, SBS- SBS-AA, SBS-TA, W-118.Min.15/32-inchplywoodSimplexMAXXCap-90.0 Elastobase,ElastobaseP(4),equallyspaced,staggeredcenterrowsTA,APP-TA APP-TA 9-inch o.c.in 4-inch lap and 9-inch o.c. in four W-119.Min.15/32-inchplywoodPolyglassBaseSimplexMAXXCapAPP-TAAPP-TA-90.0 (4),equallyspaced,staggeredcenterrows SBS-SA, APP-SA, 6-inch o.c. at 2-inch lap and 6-inch o.c. in twoBP-AA, SBS-AA, SBS- SBS-AA, SBS-TA, W-120.Min.15/32-inchplywoodElastobase,ElastobasePSimplexMAXXCap-90.0 (2),equallyspaced,staggeredcenterrowsTA,APP-TA APP-TA SBS-SA, APP-SA, 6-inch o.c. at 2-inch lap and 6-inch o.c. in threeBP-AA, SBS-AA, SBS- SBS-AA, SBS-TA, W-121.Min.15/32-inchplywoodElastobase,ElastobasePSimplexMAXXCap-105.0 (3),equallyspaced,staggeredcenterrowsTA,APP-TA APP-TA SBS-SA, APP-SA, Elastobase,ElastobasePor32 ga., 1-5/8-inch diameter tin caps with6-inch o.c. in 4-inch lap and 6-inch o.c. in fourBP-AA, SBS-AA, SBS- W-122.Min.19/32-inchplywoodSBS-AA, SBS-TA,-112.5 Elastovent11ga.annularring shanknails(3),equallyspaced,staggeredcenterrowsTA,APP-TA APP-TA S ELF-A DHERING B ASE P LY: Min. 15/32-inch SimplexMAXXCap 8-incho.c.atmin.3-inchlapand8-incho.c.at (existing)ormin.19/32- SBS-SA,APP-SA, W-123.Elastobase(poly-filmtop)three (3), equally spaced, staggered centerSBS-SA-60.0 Note:MAXXCapsaretobeprimedwith inch (new) APA rated SBS-TA,APP-TA rows PG100orASTMD41primer plywood Elastobase,ElastobaseP32 ga., 1-5/8-inch diameter tin caps with8-incho.c.in4-inchlapand8-incho.c.inthreeSBS-SA,APP-SA, W-124.Min.19/32-inchplywoodSBS-SA-60.0 (poly-filmtop)11ga.annularring shanknails(3),equallyspaced,staggeredcenterrowsSBS-TA,APP-TA Elastobase,ElastobaseP32 ga., 1-5/8-inch diameter tin caps with4-inch o.c.in 4-inch lap and 4-inch o.c. in fourSBS-SA,APP-SA, W-125.Min.19/32-inchplywoodSBS-SA-97.5 (poly-filmtop)11ga.annularringshanknails.(4),equallyspaced,staggeredcenterrowsSBS-TA,APP-TA 32 ga., 1-5/8-inch diameter tin caps with Elastoflex SA V Plus, Elastobase,ElastobaseP11 ga.annular ring shank nails.Note: Tin 6-inch o.c. in 4-inch lap and 6-inch o.c. in fourSBS-SA,APP-SA, W-126.Min.19/32-inchplywoodElastoflex SA V Plus-112.5 (poly-filmtop)caps are to be primed with PG100 or(4),equallyspaced,staggeredcenterrowsSBS-TA,APP-TA FR ASTMD41primer. H YBRID S YSTEMSWITH S ELF-A DHERING APPB ASE P LY: Elastobase,ElastobaseP32 ga., 1-5/8-inch diameter tin caps with8-incho.c.in4-inchlapand8-incho.c.inthree W-127.Min.19/32-inchplywoodAPP-SA-HAPP-TA-60.0 (poly-filmtop)11ga.annularring shanknails(3),equallyspaced,staggeredcenterrows Elastobase,ElastobaseP32 ga., 1-5/8-inch diameter tin caps with4-inch o.c.in 4-inch lap and 4-inch o.c. in four W-128.Min.19/32-inchplywoodAPP-SA-HAPP-TA-97.5 (poly-filmtop)11ga.annularringshanknails.(4),equallyspaced,staggeredcenterrows 32 ga., 1-5/8-inch diameter tin caps with Elastobase,ElastobaseP11 ga.annular ring shank nails.Note: Tin 6-inch o.c. in 4-inch lap and 6-inch o.c. in four W-129.Min.19/32-inchplywoodAPP-SA-HAPP-TA-112.5 (poly-filmtop)caps are to be primed with PG100 or(4),equallyspaced,staggeredcenterrows ASTMD41primer. NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 24of83 N EMO|etc. TABLE1F:WOODDECKS–NEWCONSTRUCTION OR REROOF(T EAR-O FF) SYSTEMTYPEE-2:NON-INSULATED,MECHANICALLYATTACHEDBASESHEET(NAILS),BONDEDROOFCOVER BaseSheetRoofCover(Note15) SystemMDP Deck(Note1) No. (psf) TypeFasten(Note11)AttachBasePlyCapPly H YBRID S YSTEMSWITH S ELF-A DHERING SBSB ASE P LY: SimplexMAXXCap 8-incho.c.atmin.3-inchlapand8-incho.c.at Min.15/32”APA rated three (3), equally spaced, staggered center W-130.Elastobase(poly-filmtop)SBS-SA-HSBS-TA-60.0 Note:MAXXCapsaretobeprimedwith plywood rows PG100orASTMD41primer 8-incho.c.atmin.4-inchlapand8-incho.c.at Elastobase,ElastobaseP32 ga., 1-5/8-inch diameter tin caps with three (3), equally spaced, staggered center W-131.Min.19/32-inchplywoodSBS-SA-HSBS-TA-60.0 (poly-filmtop)11ga.annularring shanknails rows 4-incho.c.atmin.4-inchlapand4-incho.c.at Elastobase,ElastobaseP32 ga., 1-5/8-inch diameter tin caps with W-132.Min.19/32-inchplywoodfour (4), equally spaced, staggered centerSBS-SA-HSBS-TA-97.5 (poly-filmtop)11ga.annularringshanknails. rows TABLE1G:WOODDECKS–NEWCONSTRUCTION,REROOF(T EAR-O FF)OR R ECOVER SYSTEMTYPEE-2:NON-INSULATED,MECHANICALLYATTACHEDBASESHEET(SCREWS&PLATES),BONDEDROOFCOVER BaseSheetRoofCover(Note15) SystemMDP Deck(Note1) No.(psf) TypeFasten(Note11)AttachBasePlyCap N O B ASE P LY: Elastobase, Elastobase P, Elastovent, Polyglass G2 OMG Flat Bottom Plates (square) with Roofgrip Min.19/32-inch12-inch o.c. in 4-inch lap and 12-inch o.c. in twoSBS-AA, SBS-TA, Base, CertainTeed#14, Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with W-133.None-52.5 plywoodGlasbase, Firestone MBDekfast #14 or Trufast 3” Metal Insulation Plate(2),equallyspaced,staggeredcenterrowsAPP-TA Base, JM Perma-Ply 28 orwithTrufast #14 HD GAFGLAS#75 Min.19/32-inchElastobase,ElastobasePOMGFlatBottomPlates(square)withRoofgrip12-inch o.c. in 4-inch lap and 12-inch o.c. in twoSBS-AA, SBS-TA, W-134.None-60.0 plywoodorElastovent#12(2),equallyspaced,staggeredcenterrowsAPP-TA TrufastVersa Fasteners (min. ¾” penetration) & Min.19/32-inch12-incho.c.atmin.4-inchlapand12-incho.c. Elastobase,ElastobasePPlates; 2 screws per plate installed 180° into theSBS-AA, SBS-TA, None-67.5 APA ratedat two (2), equally spaced, staggered center orElastoventholes of the plate, parallel to the width-directionAPP-TA plywoodrows W-135. ofthesheet* *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 199 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to Note: produceMinimum CharacteristicResistanceForce(MCRF) Trufast Versa Fasteners (min. ¾” penetration) & 12-incho.c.atmin.4-inchlapand12-incho.c. Min.19/32-inch Elastobase,ElastobasePPlates; 2 screws per plate installed 180° into the APA ratedat two (2), equally spaced, staggered centerNoneSBS-SA,APP-SA-67.5 (poly-filmtop)holes of the plate, parallel to the width-direction plywoodrows W-136. ofthesheet* Note:*For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 199 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produceMinimum CharacteristicResistance Force(MCRF) NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 25of83 N EMO|etc. TABLE1G:WOODDECKS–NEWCONSTRUCTION,REROOF(T EAR-O FF)OR R ECOVER SYSTEMTYPEE-2:NON-INSULATED,MECHANICALLYATTACHEDBASESHEET(SCREWS&PLATES),BONDEDROOFCOVER BaseSheetRoofCover(Note15) SystemMDP Deck(Note1) No. (psf) TypeFasten(Note11)AttachBasePlyCap Trufast Versa Fasteners (min. ¾” penetration) & Min.19/32-inch12-incho.c.atmin.4-inchlapand12-incho.c. Plates; 2 screws per plate installed 180° into the APA ratedPolyglassBaseat two (2), equally spaced, staggered centerNoneAPP-TA-67.5 holes of the plate, parallel to the width-direction plywoodrows W-137. ofthesheet* Note:*For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 199 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produceMinimum CharacteristicResistance Force(MCRF) Dekfast Hex (aka, DekfastPLT-H-2-7/8) with Polyglass G2 Base,Dekfast #14, OMG 3” Round Metal Plate with10-inch o.c. in 4-inch lap and 10-inch o.c. in Min.15/32-inchSBS-AA, SBS-TA, W-138.Elastobase,ElastobasePOMGHD,OMGFlatBottomPlate(Accutrac)withthree (3), equally spaced, staggered centerNone-75.0 plywoodAPP-TA orElastoventRoofgrip #14 or Trufast 3” Metal Insulation Platerows withTrufast #14 HD. Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with 10-inch o.c. in 4-inch lap and 10-inch o.c. in Dekfast #14, OMG 3” Round Metal Plate with Min.15/32-inch W-139.PolyglassBaseNoneAPP-TA-75.0 OMGHD,OMGFlatBottomPlate(Accutrac)withthree (3), equally spaced, staggered center plywood Roofgrip #14 or Trufast 3” Metal Insulation Platerows withTrufast #14 HD. Min. 15/32-inch Trufast Versa Fasteners (min. ¾” penetration) & (existing) or min. Elastobase,ElastobasePPlates; 2 screws per plate installed 180° into the9-incho.c.atmin.2-inchlapand12-incho.c.atSBS-AA, SBS-TA, 19/32-inch (new)None-90.0 orElastoventholes of the plate, parallel to the width-directiontwo(2),equallyspaced,staggeredcenterrowsAPP-TA APA rated W-140. ofthesheet* plywood Note:*For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 159 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produceMinimum CharacteristicResistance Force(MCRF). Min. 15/32-inch TrufastVersa Fasteners (min. ¾” penetration) & (existing) or min. Plates; 2 screws per plate installed 180° into the 9-incho.c.atmin.2-inchlapand12-incho.c.at 19/32-inch (new)PolyglassBaseNoneAPP-TA-90.0 holes of the plate, parallel to the width-direction two(2),equallyspaced,staggeredcenterrows APA rated W-141. ofthesheet* plywood Note:*For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 159 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produceMinimum CharacteristicResistance Force(MCRF). Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Polyglass G2 Base,Dekfast #14, OMG 3” Round Metal Plate with Min.15/32-inch9-inch o.c. in 4-inch lap and 9-inch o.c. in fourSBS-AA, SBS-TA, W-142.Elastobase,ElastobasePOMGHD,OMGFlatBottomPlate(Accutrac)withNone-90.0 plywood(4),equallyspaced,staggeredcenterrowsAPP-TA orElastoventRoofgrip #14 or Trufast 3” Metal Insulation Plate withTrufast #14 HD. NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 26of83 N EMO|etc. TABLE1G:WOODDECKS–NEWCONSTRUCTION,REROOF(T EAR-O FF)OR R ECOVER SYSTEMTYPEE-2:NON-INSULATED,MECHANICALLYATTACHEDBASESHEET(SCREWS&PLATES),BONDEDROOFCOVER BaseSheetRoofCover(Note15) SystemMDP Deck(Note1) No. (psf) TypeFasten(Note11)AttachBasePlyCap Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14, OMG 3” Round Metal Plate with Min.15/32-inch9-inch o.c. in 4-inch lap and 9-inch o.c. in four W-143.PolyglassBaseOMGHD,OMGFlatBottomPlate(Accutrac)withNoneAPP-TA-90.0 plywood(4),equallyspaced,staggeredcenterrows Roofgrip #14 or Trufast3” Metal Insulation Plate withTrufast #14 HD. Min.15/32-inchElastobase,ElastobasePTrufast#12DPorTrufast#14HDwithTrufast3”6-inch o.c. at 4-inch lap and 6-inch o.c. in three W-144.NoneSBS-AA-90.0 plywoodorElastoventMetalInsulationPlates(3),equallyspaced,staggeredcenterrows OMG #12 Standard Roofgrip or OMG #14 Heavy Min.15/32-inchElastobase,ElastobaseP6-inch o.c. at 4-inch lap and 6-inch o.c. in threeSBS-AA,SBS-TAor Duty with OMG 3” Round Metal Plates or OMG W-145.None-90.0 plywoodorElastovent(3),equallyspaced,staggeredcenterrowsAPP-TA FlatBottomMetal Plates OMG #12 Standard Roofgrip or OMG #14 Heavy Min.15/32-inch6-inch o.c. at 4-inch lap and 6-inch o.c. in three Duty with OMG 3” Round Metal Plates or OMG W-146.PolyglassBaseNoneAPP-TA-90.0 plywood (3),equallyspaced,staggeredcenterrows FlatBottomMetal Plates Min. 15/32-inch Trufast Versa Fasteners (min. ¾” penetration) & (existing) or min.6-incho.c.atmin.4-inchlapand6-incho.c.at Plates; 2 screws per plate installed 180° into the Elastobase,ElastobasePSBS-AA, SBS-TA, 19/32-inch (new)three (3), equally spaced, staggered centerNone-105.0 orElastoventholes of the plate, parallel to the width-directionAPP-TA APA ratedrows W-147. ofthesheet* plywood *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 103 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to Note: produceMinimum CharacteristicResistance Force(MCRF). Min. 15/32-inch Trufast Versa Fasteners (min. ¾” penetration) & (existing) or min.6-incho.c.atmin.4-inchlapand6-incho.c.at Plates; 2 screws per plate installed 180° into the 19/32-inch (new)PolyglassBasethree (3), equally spaced, staggered centerNoneAPP-TA-105.0 holes of the plate, parallel to the width-direction rows APA rated W-148. ofthesheet* plywood Note:*For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 103 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produceMinimum CharacteristicResistance Force(MCRF). Min.15/32-inchElastobase,ElastobasePTrufast#12DPorTrufast#14HDwithTrufast3”6-inch o.c.at 4-inch lap and 6-inch o.c. in five W-149.NoneSBS-AA-120.0 plywoodorElastovent(5),equallyspaced,staggeredcenterrows MetalInsulationPlates OMG #12 Standard Roofgrip or OMG #14 Heavy Min.15/32-inchElastobase,ElastobaseP6-inch o.c. at 4-inch lap and 6-inch o.c. in fiveSBS-AA,SBS-TAor Duty with OMG 3” Round Metal Plates or OMG W-150.None-120.0 plywoodorElastovent(5),equallyspaced,staggeredcenterrowsAPP-TA FlatBottomMetal Plates OMG #12 Standard Roofgripor OMG #14 Heavy Min.15/32-inch6-inch o.c. at 4-inch lap and 6-inch o.c. in five Duty with OMG 3” Round Metal Plates or OMG W-151.PolyglassBaseNoneAPP-TA-120.0 plywood(5),equallyspaced,staggeredcenterrows FlatBottomMetal Plates A SPHALT-A PPLIEDOR T ORCH-A PPLIED B ASE P LY: NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 27of83 N EMO|etc. TABLE1G:WOODDECKS–NEWCONSTRUCTION,REROOF(T EAR-O FF)OR R ECOVER SYSTEMTYPEE-2:NON-INSULATED,MECHANICALLYATTACHEDBASESHEET(SCREWS&PLATES),BONDEDROOFCOVER BaseSheetRoofCover(Note15) SystemMDP Deck(Note1) No. (psf) TypeFasten(Note11)AttachBasePlyCap Elastobase, Elastobase P, Elastovent, Polyglass G2OMG Flat Bottom Plates (square) with Roofgrip SBS-SA, APP-SA, Min.19/32-inchBase, CertainTeed#14, Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with12-inch o.c. in 4-inch lap and 12-inch o.c. in twoBP-AA, SBS-AA, W-152.-52.5 SBS-AA, SBS-TA, plywoodGlasbase, Firestone MBDekfast #14 or Trufast 3” Metal Insulation Plate(2),equallyspaced,staggeredcenterrowsSBS-TA,APP-TA APP-TA Base, JM Perma-Ply 28 orwithTrufast #14 HD GAFGLAS#75 SBS-SA, APP-SA, Min.19/32-inchElastobase,ElastobasePOMGFlatBottomPlates(square)withRoofgrip12-inch o.c.in 4-inch lap and 12-inch o.c. in twoBP-AA, SBS-AA, W-153.SBS-AA, SBS-TA,-60.0 plywoodorElastovent#12(2),equallyspaced,staggeredcenterrowsSBS-TA,APP-TA APP-TA TrufastVersa Fasteners (min. ¾” penetration) & Min.19/32-inch12-incho.c.atmin.4-inchlapand12-incho.c.SBS-SA, APP-SA, Elastobase,ElastobasePPlates; 2 screws per plate installed 180° into theBP-AA, SBS-AA, APA ratedat two (2), equally spaced, staggered centerSBS-AA, SBS-TA,-67.5 orElastoventholes of the plate, parallel to the width-directionSBS-TA,APP-TA plywoodrowsAPP-TA W-154. ofthesheet* Note:*Forre-rooforrecoverconstruction,fieldwithdrawalresistancetesting(Note11)shallyieldMCRF>199lbf.AdditionalVersa-FastFastenerswithineachVersa-FastPlatemaybeutilizedto produceMinimum CharacteristicResistance Force(MCRF). Trufast Versa Fasteners (min. ¾” penetration) & 12-incho.c.atmin.4-inchlapand12-incho.c. Min.19/32-inch Plates; 2 screws per plate installed 180° into the PolyglassBaseAPP-TAAPP-TA-67.5 APA ratedat two (2), equally spaced, staggered center holes of the plate, parallel to the width-direction plywoodrows W-155. ofthesheet* Note:*For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 199 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produceMinimum CharacteristicResistance Force(MCRF). Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Polyglass G2 Base,Dekfast #14, OMG 3” Round Metal Plate with10-inch o.c. in 4-inch lap and 10-inch o.c. inSBS-SA, APP-SA, Min.15/32-inchBP-AA, SBS-AA, W-156.Elastobase,ElastobasePOMGHD,OMGFlatBottomPlate(Accutrac)withthree (3), equally spaced, staggered centerSBS-AA, SBS-TA,-75.0 plywoodSBS-TA,APP-TA orElastoventRoofgrip #14 or Trufast 3” Metal Insulation PlaterowsAPP-TA withTrufast #14 HD. DekfastHex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14, OMG 3” Round Metal Plate with 10-inch o.c. in 4-inch lap and 10-inch o.c. in Min.15/32-inch W-157.PolyglassBaseOMGHD,OMGFlatBottomPlate(Accutrac)withAPP-TAAPP-TA-75.0 three (3), equally spaced, staggered center plywood Roofgrip #14 or Trufast 3” Metal Insulation Platerows withTrufast #14 HD. Min. 15/32-inch TrufastVersa Fasteners (min. ¾” penetration) & (existing) or min.SBS-SA, APP-SA, Elastobase,ElastobasePPlates; 2 screws per plate installed 180° into the9-incho.c.atmin.2-inchlapand12-incho.c.atBP-AA, SBS-AA, W-158.19/32-inch (new)SBS-AA, SBS-TA,-90.0 orElastoventholes of the plate, parallel to the width-directiontwo(2),equallyspaced,staggeredcenterrowsSBS-TA,APP-TA APA ratedAPP-TA ofthesheet* plywood NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 28of83 N EMO|etc. TABLE1G:WOODDECKS–NEWCONSTRUCTION,REROOF(T EAR-O FF)OR R ECOVER SYSTEMTYPEE-2:NON-INSULATED,MECHANICALLYATTACHEDBASESHEET(SCREWS&PLATES),BONDEDROOFCOVER BaseSheetRoofCover(Note15) SystemMDP Deck(Note1) No. (psf) TypeFasten(Note11)AttachBasePlyCap *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 159 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to Note: produceMinimumCharacteristicResistance Force(MCRF). Min. 15/32-inch TrufastVersa Fasteners (min. ¾” penetration) & (existing) or min. Plates; 2 screws per plate installed 180° into the9-incho.c.atmin.2-inchlapand12-incho.c.at 19/32-inch (new)PolyglassBaseAPP-TAAPP-TA-90.0 holes of the plate, parallel to the width-directiontwo(2),equallyspaced,staggeredcenterrows APA rated W-159. ofthesheet* plywood Note:*For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 159 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produceMinimum CharacteristicResistance Force(MCRF). Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Polyglass G2 Base,Dekfast #14, OMG 3” Round Metal Plate withSBS-SA, APP-SA, Min.15/32-inch9-inch o.c. in 4-inch lap and 9-inch o.c. in fourBP-AA, SBS-AA, W-160.Elastobase,ElastobasePOMGHD,OMGFlatBottomPlate(Accutrac)withSBS-AA, SBS-TA,-90.0 plywood(4),equallyspaced,staggeredcenterrowsSBS-TA,APP-TA orElastoventRoofgrip #14 or Trufast 3” Metal Insulation PlateAPP-TA withTrufast #14 HD. Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14, OMG 3” Round Metal Plate with Min.15/32-inch9-inch o.c. in 4-inch lap and 9-inch o.c. in four W-161.PolyglassBaseOMGHD,OMGFlatBottomPlate(Accutrac)withAPP-TAAPP-TA-90.0 plywood(4),equallyspaced,staggeredcenterrows Roofgrip #14 or Trufast3” Metal Insulation Plate withTrufast #14 HD. Min.15/32-inchElastobase,ElastobasePTrufast#12DPorTrufast#14HDwithTrufast3”6-inch o.c. at 4-inch lap and 6-inch o.c. in three W-162.BP-AAorSBS-AASBS-AA-90.0 plywoodorElastoventMetalInsulationPlates(3),equallyspaced,staggeredcenterrows OMG #12 Standard Roofgrip or OMG #14 HeavySBS-SA, APP-SA, Min.15/32-inchElastobase,ElastobaseP6-inch o.c. at 4-inch lap and 6-inch o.c. in threeBP-AA, SBS-AA, Duty (min. 1-5/8-inch long) with OMG 3” RoundSBS-AA, SBS-TA, W-163.-90.0 plywoodorElastovent (3),equallyspaced,staggeredcenterrowsSBS-TA,APP-TA MetalPlatesorOMGFlat BottomMetalPlatesAPP-TA OMG#12StandardRoofgriporOMG#14Heavy Min.15/32-inch6-inch o.c.at 4-inch lap and 6-inch o.c. in three W-164.PolyglassBaseDuty with OMG 3” Round Metal Plates or OMGAPP-TAAPP-TA-90.0 plywood (3),equallyspaced,staggeredcenterrows FlatBottomMetal Plates Min. 15/32-inch TrufastVersa Fasteners (min. ¾” penetration) & (existing) or min.6-incho.c.atmin.4-inchlapand6-incho.c.atSBS-SA, APP-SA, Elastobase,ElastobasePPlates; 2 screws per plate installed 180° into theBP-AA, SBS-AA, 19/32-inch (new)three (3), equally spaced, staggered centerSBS-AA, SBS-TA,-105.0 orElastoventholes of the plate, parallel to the width-directionSBS-TA,APP-TA APA ratedrowsAPP-TA W-165. ofthesheet* plywood Note:*For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 103 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produceMinimum CharacteristicResistance Force(MCRF). NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 29of83 N EMO|etc. TABLE1G:WOODDECKS–NEWCONSTRUCTION,REROOF(T EAR-O FF)OR R ECOVER SYSTEMTYPEE-2:NON-INSULATED,MECHANICALLYATTACHEDBASESHEET(SCREWS&PLATES),BONDEDROOFCOVER BaseSheetRoofCover(Note15) SystemMDP Deck(Note1) No. (psf) TypeFasten(Note11)AttachBasePlyCap Min. 15/32-inch Trufast Versa Fasteners (min. ¾” penetration) & (existing) or min.6-incho.c.atmin.4-inchlapand6-incho.c.at Plates; 2 screws per plate installed 180° into the 19/32-inch (new)PolyglassBasethree (3), equally spaced, staggered centerAPP-TAAPP-TA-105.0 holes of the plate, parallel to the width-direction APA ratedrows W-166. ofthesheet* plywood Note:*For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 103 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produceMinimumCharacteristicResistance Force(MCRF). Min.15/32-inchElastobase,ElastobasePTrufast#12DPorTrufast#14HDwithTrufast3”6-inch o.c. at 4-inch lap and 6-inch o.c. in five W-167.BP-AAorSBS-AASBS-AA-120.0 plywoodorElastoventMetalInsulationPlates(5),equallyspaced,staggeredcenterrows OMG #12 Standard Roofgrip or OMG #14 HeavySBS-SA, APP-SA, Min.15/32-inchElastobase,ElastobaseP6-inch o.c. at 4-inch lap and 6-inch o.c. in fiveBP-AA, SBS-AA, Duty with OMG 3” Round Metal Plates or OMGSBS-AA, SBS-TA, W-168.-120.0 plywoodorElastovent(5),equallyspaced,staggeredcenterrowsSBS-TA,APP-TA FlatBottomMetal PlatesAPP-TA OMG #12 Standard Roofgripor OMG #14 Heavy Min.15/32-inch6-inch o.c. at 4-inch lap and 6-inch o.c. in five Duty with OMG 3” Round Metal Plates or OMG W-169.PolyglassBaseAPP-TAAPP-TA-120.0 plywood(5),equallyspaced,staggeredcenterrows FlatBottomMetal Plates Min.19/32-inch Elastobase(sandedtop)TrufastVersaFasteners(min.¾”penetration)&9-incho.c.atmin.4-inchlapand9-incho.c.atBP-AA, SBS-AA,SBS-AA, SBS-TA, APA rated-127.5 orElastoventPlates;1screwsperplateincenterhole*four(4),equallyspacedcenterrowsSBS-TA,APP-TAAPP-TA plywood W-170. Note:*For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 141 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce minimum withdrawalresistance Min.19/32-inch TrufastVersaFasteners(min.¾”penetration)&9-incho.c.atmin.4-inchlapand9-incho.c.at APA rated Elastobase(poly-filmtop)SBS-TASBS-TA,APP-TA-127.5 Plates;1screwsperplateincenterhole*four(4),equallyspacedcenterrows plywood W-171. Note:*For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 141 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce minimum withdrawalresistance Min.19/32-inch TrufastVersaFasteners(min.¾”penetration)&9-incho.c.atmin.4-inchlapand9-incho.c.at APA rated PolyglassBaseAPP-TAAPP-TA-127.5 Plates;1screwsperplateincenterhole*four(4),equallyspacedcenterrows plywood W-172. Note:*For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 141 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce minimum withdrawalresistance S ELF-A DHERING B ASE P LY: Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Min.19/32-inchElastobase,ElastobaseP12-inch o.c. in 4-inch lap and 12-inch o.c. in twoSBS-SA,APP-SA, Dekfast #14 or Trufast3” Metal Insulation Plate W-173.SBS-SA-52.5* plywood(poly-filmtop)SBS-TA,APP-TA (2),equallyspaced,staggeredcenterrows withTrufast #14 HD Min.19/32-inchElastobase,ElastobasePOMGFlatBottomPlates(square)withRoofgrip12-inch o.c. in 4-inch lap and 12-inch o.c. in twoSBS-SA,APP-SA, W-174.SBS-SA-60.0* plywood(poly-filmtop)#12(2),equallyspaced,staggeredcenterrowsSBS-TA,APP-TA NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 30of83 N EMO|etc. TABLE1G:WOODDECKS–NEWCONSTRUCTION,REROOF(T EAR-O FF)OR R ECOVER SYSTEMTYPEE-2:NON-INSULATED,MECHANICALLYATTACHEDBASESHEET(SCREWS&PLATES),BONDEDROOFCOVER BaseSheetRoofCover(Note15) SystemMDP Deck(Note1) No. (psf) TypeFasten(Note11)AttachBasePlyCap Trufast Versa Fasteners (min. ¾” penetration) & Min.19/32-inch12-incho.c.atmin.4-inchlapand12-incho.c. Elastobase,ElastobasePPlates; 2 screws per plate installed 180° into theSBS-SA,APP-SA, APA ratedat two (2), equally spaced, staggered centerSBS-SA-67.5 (poly-filmtop)holes of the plate, parallel to the width-directionSBS-TA,APP-TA plywoodrows W-175. ofthesheet* Note:*For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 199 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produceMinimum CharacteristicResistance Force(MCRF). TrufastVersaFasteners(min.¾”penetration)& Min.19/32-inch Plates; 1 screws per plate in center hole* 9-incho.c.atmin.4-inchlapand9-incho.c.atSBS-SA,APP-SA, APA ratedElastobase(poly-filmtop)SBS-SA-127.5 Note:Versa-FastPlatesshallbeprimedwith four(4), equallyspacedcenterrowsSBS-TA,APP-TA plywood W-176. PG100orASTMD41 primer. Note:*For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 141 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce minimum withdrawalresistance H YBRID S YSTEMSWITH S ELF-A DHERING APPB ASE P LY: Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Min.19/32-inchElastobase,ElastobaseP12-inch o.c. in 4-inch lap and 12-inch o.c. in two W-177.Dekfast #14 or Trufast3” Metal Insulation PlateAPP-SA-HAPP-TA-52.5* plywood(poly-filmtop) (2),equallyspaced,staggeredcenterrows withTrufast #14 HD Min.19/32-inchElastobase,ElastobasePOMGFlatBottomPlates(square)withRoofgrip12-inch o.c. in 4-inch lap and 12-inch o.c. in two W-178.APP-SA-HAPP-TA-60.0* plywood(poly-filmtop)#12(2),equallyspaced,staggeredcenterrows Trufast Versa Fasteners (min. ¾” penetration) & 12-incho.c.atmin.4-inchlapand12-incho.c. Min.19/32-inch Elastobase,ElastobasePPlates; 2 screws per plate installed 180° into the APA ratedat two (2), equally spaced, staggered centerAPP-SA-HAPP-TA-67.5 (poly-filmtop)holes of the plate, parallel to the width-direction plywoodrows W-179. ofthesheet* Note:*For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 199 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produceMinimum CharacteristicResistance Force(MCRF). H YBRID S YSTEMSWITH S ELF-A DHERING SBSB ASE P LY: Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with12-incho.c.atmin.4-inchlapand12-incho.c. Min.19/32-inchElastobase,ElastobaseP Dekfast #14 or Trufast3” Metal Insulation Plateat two (2), equally spaced, staggered center W-180.SBS-SA-HSBS-TA-52.5* plywood(poly-filmtop) withTrufast #14 HDrows 12-incho.c.atmin.4-inchlapand12-incho.c. Min.19/32-inchElastobase,ElastobasePOMGFlatBottomPlates(square)withRoofgrip W-181.at two (2), equally spaced, staggered centerSBS-SA-HSBS-TA-60.0* plywood(poly-filmtop)#12 rows Trufast Versa Fasteners (min. ¾” penetration) & Min.19/32-inch12-incho.c.atmin.4-inchlapand12-incho.c. Elastobase,ElastobasePPlates; 2 screws per plate installed 180° into the W-182.APA ratedat two (2), equally spaced, staggered centerSBS-SA-HSBS-TA-67.5 (poly-filmtop)holes of the plate, parallel to the width-direction plywoodrows ofthesheet* NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 31of83 N EMO|etc. TABLE1G:WOODDECKS–NEWCONSTRUCTION,REROOF(T EAR-O FF)OR R ECOVER SYSTEMTYPEE-2:NON-INSULATED,MECHANICALLYATTACHEDBASESHEET(SCREWS&PLATES),BONDEDROOFCOVER BaseSheetRoofCover(Note15) SystemMDP Deck(Note1) No. (psf) TypeFasten(Note11)AttachBasePlyCap *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 199 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to Note: produceMinimum CharacteristicResistance Force(MCRF). TrufastVersaFasteners(min.¾”penetration)& Min.19/32-inch Plates;1screwsperplateincenterhole* 9-incho.c.atmin.4-inchlapand9-incho.c.at Elastobase(poly-filmtop)SBS-SA-HSBS-TA-127.5 APA rated four(4),equallyspacedcenterrows Note:Versa-FastPlatesshallbeprimedwith plywood W-183. PG100orASTMD41 primer. *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 141 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to Note: produce minimum withdrawalresistance NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 32of83 N EMO|etc. TABLE2A:STEELORSTRUCTURALCONCRETEDECKS–NEWCONSTRUCTION,REROOF(T EAR-O FF)OR RECOVER SYSTEMTYPEB-1:MECHANICALLYATTACHEDBASEINSULATION,BONDEDTOPINSULATION,BONDEDROOFCOVER BaseInsulationLayerTopInsulationLayerRoofCover(Note15) Deck SystemMDP Attach No. (psf) (Note1) TypeFasten(Note11)AttachTypeBasePlyPlyCapPly (Notes6,7,8) A SPHALT-OR T ORCH-A PPLIED B ASE P LY: Min. 22 ga., typeDekfast Hex (aka, Dekfast PLT-H-2- Min. 0.75-inch Fesco Board(Optional if(Optional if using B, Grade 33 steelMin.1.5-inchPolytherm,7/8) with Dekfast #14, Trufast 3”SBS-AA, (homogeneous) or min. 0.5-inchusing AAAA Base) BP-AA, 1per SC-1.or min. 2,500 psiACFoamII,ENRGY 3,H-Metal Insulation Plate with TrufastHotasphaltSBS-TA,-45.0* 2 Structodek High DensityPly) BP-AA,SBS-AA,SBS-TAor 2.0ft structuralShieldorPolytherm#14 HD or OMG 3-inch Galv PlateAPP-TA FiberboardRoofInsulationSBS-AAAPP-TA concretewithOMD HD Min. 22 ga., typeDekfast Hex (aka, Dekfast PLT-H-2- Min. 0.75-inch Fesco Board(Optional if(Optional if using B, Grade 33 steelMin. 2-inch Polytherm,7/8) with Dekfast #14, Trufast 3”SBS-AA, 1per(homogeneous) or min. 0.5-inchusing AAAA Base) BP-AA, SBS-TA, SC-2.or min. 2,500 psiACFoamII,ENRGY3,H-Metal Insulation Plate with TrufastHotasphalt-45.0* 2 Structodek High DensityPly) BP-AA,SBS-AA,SBS-TAor 4.0ft structural#14 HD or OMG 3-inch Galv PlateAPP-TA ShieldorPolytherm FiberboardRoofInsulationSBS-AAAPP-TA concretewithOMD HD Min. 22 ga., type Dekfast Hex (aka, Dekfast PLT-H-2-Min. 0.75-inch Fesco Board(Optional if(Optional if using B, Grade 33 steelSBS-AA, Min.1.5-inchENRGY3,7/8)withDekfast#14orTrufast3”1per(homogeneous) or min. 0.5-inchusing AAAA Base) BP-AA, SC-3.HotasphaltSBS-TA,-90.0 or min. 2,500 psi 2 H-ShieldorPolythermMetal Insulation Plate with Trufast1.3ftStructodek High DensityPly) BP-AA,SBS-AA,SBS-TAor structural APP-TA #14HDFiberboardRoofInsulationSBS-AAAPP-TA concrete BP-AA,SBS- Min. 22 ga., type Dekfast Hex (aka, Dekfast PLT-H-2-Min. 0.75-inch Fesco BoardAA (TopSBS-SA, B, Grade 33 steel Min.1.5-inchENRGY3,1perSBS-SA,SBS-TAor 7/8)withDekfast#14orTrufast3”(homogeneous) or min. 0.5-inchsurfaceAPP-SA, SC-4.or min. 2,500 psiHotasphalt-90.0 2 H-ShieldorPolythermMetal Insulation Plate with Trufast1.3ftStructodek High DensityprimedAPP-TASBS-TA or structural #14HDFiberboardRoofInsulationwith PG100APP-TA concrete primer) Min. 2-inch Polytherm,Dekfast Hex (aka, Dekfast PLT-H-2- Min. 22 ga., type ACFoamII,ENRGY 3,7/8) with Dekfast #14, OMG 3”Min. 0.25-inch DensDeckPrime, B, Grade 40 steelSBS-AA,SBS-AA, EnergyGuard PolyisoGalvalume Ribbons Plates with1perDEXcell FA Glass Mat Roof(Optional)SBS-AA, SC-5.or min. 2,500 psiD-ISSBS-TA,-45.0 SBS-TA, 2 Insulation,PolythermH,OMG #14 Roofgrip or Trufast 3”1.6ftBoard or SECUROCK Gypsum-SBS-TA,APP-TA structuralAPP-TAAPP-TA Metal Insulation Plate with TrufastFiberRoofBoard H-Shield or Multi-Max concrete FA3#14HD Min.0.25-inchDensDeckPrime, Min. 2-inch Polytherm,Dekfast Hex (aka, Dekfast PLT-H-2-DEXcell FA Glass Mat Roof Min. 22 ga., type ACFoamII,ENRGY 3,7/8) with Dekfast #14, OMG 3” Board, SECUROCK Gypsum- B, Grade 40 steelSBS-AA,SBS-AA, Galvalume Ribbons Plates with1perFiber Roof Board or SECUROCKM-OSFA or(Optional)SBS-AA, EnergyGuard Polyiso SC-6.SBS-TA,-45.0 or min. 2,500 psiSBS-TA, 2 Insulation,PolythermH,OMG #14 Roofgrip or Trufast 3”1.6ftGlass-MatRoofBoard,min.M-PG1SBS-TA,APP-TA structuralAPP-TAAPP-TA Metal Insulation Plate with Trufast H-Shield or Multi-Max7/16-inchDEXcellCementRoof concrete FA3#14HD Board or min. 0.5-inch SECUROCKCementRoofBoard NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 33of83 N EMO|etc. TABLE2A:STEELORSTRUCTURALCONCRETEDECKS–NEWCONSTRUCTION,REROOF(T EAR-O FF)OR RECOVER SYSTEMTYPEB-1:MECHANICALLYATTACHEDBASEINSULATION,BONDEDTOPINSULATION,BONDEDROOFCOVER BaseInsulationLayerTopInsulationLayerRoofCover(Note15) Deck SystemMDP Attach No. (psf) (Note1) TypeFasten(Note11)AttachTypeBasePlyPlyCapPly (Notes6,7,8) Min. 2-inch Polytherm,DekfastHex (aka, Dekfast PLT-H-2- Min. 22 ga., type ACFoamII,ENRGY 3,7/8) with Dekfast #14, OMG 3”Min. 0.25-inch DensDeck Prime, B, Grade 40 steelSBS-AA,SBS-AA, EnergyGuard PolyisoGalvalume Ribbons Plates with1perDEXcell FA Glass Mat Roof(Optional)SBS-AA, SC-7.or min. 2,500 psiOB500SBS-TA,-45.0 SBS-TA, 2 Insulation,PolythermH,OMG #14 Roofgrip or Trufast 3”1.6ftBoard or SECUROCK Gypsum-SBS-TA,APP-TA structuralAPP-TAAPP-TA Metal Insulation Plate with TrufastFiberRoofBoard H-Shield or Multi-Max concrete FA3#14HD Min. 2-inch Polytherm,Dekfast Hex (aka, Dekfast PLT-H-2- Min. 22 ga., type ACFoamII,ENRGY 3,7/8) with Dekfast #14, OMG 3” B, Grade 40 steelMin.0.25-inchDensDeckPrimeSBS-AA,SBS-AA, EnergyGuard Polyiso1per(Optional)SBS-AA, Galvalume Ribbons Plates with or min. 2,500 psiSBS-TA, SC-8.or SECUROCK Gypsum-FiberCR-20SBS-TA,-45.0 2 Insulation,PolythermH,OMG #14 Roofgrip or Trufast 3”SBS-TA,APP-TA 1.6ft structuralRoofBoardAPP-TAAPP-TA H-Shield or Multi-MaxMetal Insulation Plate with Trufast concrete FA3#14HD S ELF-A DHERING B ASE P LY: Min. 2-inch Polytherm,Dekfast Hex (aka, Dekfast PLT-H-2- Min.0.25-inchDensDeckPrime Min. 22 ga., type ACFoamII,ENRGY 3,7/8) with Dekfast #14, OMG 3” or SECUROCK Gypsum-Fiber B, Grade 40 steelSBS-CA1, 1per EnergyGuard PolyisoGalvalume Ribbons Plates with RoofBoard SC-9.or min. 2,500 psiD-ISSBS-SANoneSBS-CA2,-45.0 2 OMG #14 Roofgrip or Trufast 3” Insulation,PolythermH,1.6ft structuralAPP-CA1 PRIMER:POLYBRITE 745 or H-Shield or Multi-MaxMetal Insulation Plate with Trufast concrete WB3000 FA3#14HD Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board or Min. 2-inch Polytherm,Dekfast Hex (aka, Dekfast PLT-H-2- Min. 22 ga., type SECUROCK Glass-Mat Roof ACFoamII,ENRGY 3,7/8) with Dekfast #14, OMG 3” SBS-CA1, B, Grade 40 steel Board, min. 7/16-inch DEXcell EnergyGuard PolyisoGalvalume Ribbons Plates with1perM-OSFA or SC-10.or min. 2,500 psiSBS-SANoneSBS-CA2,-45.0 2 Cement Roof Board or min. 0.5- Insulation,PolythermH,OMG #14 Roofgrip or Trufast 3”1.6ftM-PG1 structuralAPP-CA1 inch SECUROCK Cement Roof H-Shield or Multi-MaxMetal Insulation Plate with Trufast concrete Board FA3#14HD PRIMER:POLYBRITE 745 or WB3000 Min. 2-inch Polytherm,Dekfast Hex (aka, Dekfast PLT-H-2- Min.0.25-inchDensDeckPrime Min. 22 ga., type ACFoamII,ENRGY 3,7/8) with Dekfast #14, OMG 3” or SECUROCK Gypsum-Fiber B, Grade 40 steelSBS-CA1, EnergyGuard PolyisoGalvalume Ribbons Plates with1per RoofBoard SC-11.or min. 2,500 psiOB500SBS-SANoneSBS-CA2,-45.0 2 OMG #14 Roofgrip or Trufast 3” Insulation,PolythermH,1.6ft structuralAPP-CA1 PRIMER:POLYBRITE 745 or H-Shield or Multi-MaxMetal Insulation Plate with Trufast concrete WB3000 FA3#14HD NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 34of83 N EMO|etc. TABLE2A:STEELORSTRUCTURALCONCRETEDECKS–NEWCONSTRUCTION,REROOF(T EAR-O FF)OR RECOVER SYSTEMTYPEB-1:MECHANICALLYATTACHEDBASEINSULATION,BONDEDTOPINSULATION,BONDEDROOFCOVER BaseInsulationLayerTopInsulationLayerRoofCover(Note15) Deck SystemMDP Attach No. (psf) (Note1) TypeFasten(Note11)AttachTypeBasePlyPlyCapPly (Notes6,7,8) Min. 2-inch Polytherm,Dekfast Hex (aka, Dekfast PLT-H-2- Min.0.25-inchDensDeckPrime Min. 22 ga., type ACFoamII,ENRGY 3,7/8) with Dekfast #14, OMG 3” or SECUROCK Gypsum-Fiber B, Grade 40 steelSBS-CA1, EnergyGuard PolyisoGalvalume Ribbons Plates with1per RoofBoard SC-12.or min. 2,500 psiCR-20SBS-SANone-45.0 SBS-CA2, 2 Insulation,PolythermH,OMG #14 Roofgrip or Trufast 3”1.6ft structuralAPP-CA1 PRIMER:POLYBRITE 745 or Metal InsulationPlate with Trufast H-Shield or Multi-Max concrete WB3000 FA3#14HD C OLD-A PPLIED B ASE P LY: Min. 2-inch Polytherm,Dekfast Hex (aka, Dekfast PLT-H-2- Min. 22 ga., type ACFoamII,ENRGY 3,7/8) with Dekfast #14, OMG 3”Min. 0.25-inch Dens Deck B, Grade 40 steelSBS-CA1, EnergyGuard Polyiso1perSBS-CA1,(Optional)SBS- Galvalume Ribbons Plates withPrime,DEXcellFAGlassMat or min. 2,500 psi SC-13.D-ISSBS-CA2,-45.0 2 Insulation,PolythermH,OMG #14 Roofgrip or Trufast 3”1.6ftRoof Board or SECUROCKSBS-CA2CA1,SBS-CA2 structural APP-CA1 H-Shield or Multi-MaxMetal Insulation Plate with TrufastGypsum-FiberRoofBoard concrete FA3#14HD Min. 0.25-inch Dens Deck, Dens Deck Prime, DEXcell FA Glass Min. 2-inch Polytherm,Dekfast Hex (aka, Dekfast PLT-H-2- Min. 22 ga., typeMat Roof Board, SECUROCK ACFoamII,ENRGY 3,7/8) with Dekfast #14, OMG 3” SBS-CA1, B, Grade 40 steelGypsum-Fiber Roof Board or EnergyGuard PolyisoGalvalume Ribbons Plates with1perM-OSFA orSBS-CA1,(Optional)SBS- SC-14.SECUROCK Glass-Mat Roof-45.0 or min. 2,500 psiSBS-CA2, 2 Insulation,PolythermH,OMG #14 Roofgrip or Trufast 3”1.6ftM-PG1SBS-CA2CA1,SBS-CA2 structuralBoard, min. 7/16-inch DEXcellAPP-CA1 Metal Insulation Plate with Trufast H-Shield or Multi-Max concreteCement Roof Board or min. 0.5- FA3#14HD inch SECUROCK Cement Roof Board Min. 2-inch Polytherm,Dekfast Hex (aka, Dekfast PLT-H-2- Min. 22 ga., type ACFoamII,ENRGY 3,7/8) with Dekfast #14, OMG 3” Min. 0.25-inch Dens Deck B, Grade 40 steelSBS-CA1, 1perSBS-CA1,(Optional)SBS- EnergyGuard PolyisoGalvalume Ribbons Plates withPrime,DEXcellFAGlassMat SC-15.or min. 2,500 psiOB500SBS-CA2,-45.0 2 OMG #14 Roofgrip or Trufast 3”SBS-CA2CA1,SBS-CA2 Insulation,PolythermH,1.6ftRoof Board or SECUROCK structuralAPP-CA1 H-Shield or Multi-MaxMetal Insulation Plate with TrufastGypsum-FiberRoofBoard concrete FA3#14HD Min. 2-inch Polytherm,Dekfast Hex (aka, Dekfast PLT-H-2- Min. 22 ga., type ACFoamII,ENRGY 3,7/8) with Dekfast #14, OMG 3” B, Grade 40 steelMin.0.25-inchDensDeckPrimeSBS-CA1, EnergyGuard PolyisoGalvalume Ribbons Plates with1perSBS-CA1,(Optional)SBS- SC-16.or min. 2,500 psior SECUROCK Gypsum-FiberCR-20SBS-CA2,-45.0 2 Insulation,PolythermH,OMG #14 Roofgrip or Trufast 3”1.6ftSBS-CA2CA1,SBS-CA2 structural RoofBoardAPP-CA1 Metal Insulation Plate with Trufast H-Shield or Multi-Max concrete FA3#14HD NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 35of83 N EMO|etc. TABLE2B:STEELORSTRUCTURALCONCRETEDECKS–NEWCONSTRUCTION,REROOF(T EAR-O FF)OR RECOVER SYSTEMTYPEC-1:MECHANICALLYATTACHEDINSULATION,BONDEDROOFCOVER TopInsulationLayerRoofCover(Note15) SystemBase InsulationMDP Deck(Note1) No.Layer(Note13) (psf) TypeFasten (Note11)AttachBasePlyPlyCapPly A SPHALT-OR T ORCH-A PPLIED B ASE P LY: (Optional if OMGAccuTracPlateorOMG 3in.RibbedGalvalumePlatewith#12 Min. 22 ga., type B,Min. 0.75-inch JM Fesco(Optional if Oneormorelayers,using AA Base)SBS-AA, Roofgrip (steel only) or OMG #14 Heavy Duty, Dekfast Hex (aka, Grade 33 steel orBoard(homogeneous)or1perusing AA DekfastPLT-H-2-7/8) with Dekfast #12 DP (steel only) or Dekfast SC-17.any combination,BP-AA, SBS-AA,SBS-TA,-45.0* 2 Ply) BP-AA, min. 2,500 psimin. 1.5-inch JM Fesco2.0ft #14, Trufast 3” Metal Insulation Plate with Trufast #12 DP (steel looselaidSBS-TAor APP-APP-TA structuralconcreteBoard(laminated)SBS-AA only)or Trufast#14HD TA (Optional if OMGAccuTracPlateorOMG 3in.RibbedGalvalumePlatewith#12 Min. 22 ga., type B,(Optional if Oneormorelayers,Min. 0.5-inch Structodekusing AA Base)SBS-AA, Roofgrip (steel only) or OMG #14 Heavy Duty, Dekfast Hex (aka, Grade 33 steel or1perusing AA Dekfast PLT-H-2-7/8) with Dekfast #12 DP (steel only) or Dekfast SC-18.any combination,High Density FiberboardBP-AA, SBS-AA,SBS-TA,-45.0* 2 Ply) BP-AA, min. 2,500 psi4.0ft #14, Trufast3” Metal Insulation Plate with Trufast #12 DP (steel looselaidRoofInsulationSBS-TA or APP-APP-TA structuralconcreteSBS-AA only)or Trufast#14HD TA (Optional if OMGAccuTracPlateorOMG 3in.RibbedGalvalumePlatewith#12 Min. 22 ga., type B,(Optional if Oneormorelayers,Min. 0.25-inch Dens DeckSBS-AA, using AA Base) Roofgrip (steel only) or OMG #14 Heavy Duty, Dekfast Hex (aka, -45.0* Grade 33 steel or1perusing AA Dekfast PLT-H-2-7/8) with Dekfast #12 DP (steel only) or Dekfast SC-19. any combination,Prime or SECUROCKBP-AA, SBS-AA,SBS-TA, 2 min. 2,500 psi4.0ftPly) BP-AA, #14, Trufast 3” Metal Insulation Plate with Trufast #12 DP (steel looselaidGypsum-FiberRoofBoardSBS-TA or APP-APP-TA structuralconcreteSBS-AA only)or Trufast#14HD TA (Optional if OMGAccuTracPlateorOMG 3in.RibbedGalvalumePlatewith#12 Min. 22 ga., type B,(Optional) One or(Optional if using AA Base)SBS-AA, Roofgrip (steel only) or OMG #14 Heavy Duty, Dekfast Hex (aka, Grade 33 steel ormore layers, any1perusing AA Dekfast PLT-H-2-7/8) with Dekfast #12 DP (steel only) or Dekfast SC-20.Min.2-inchH-ShieldWFBP-AA, SBS-AA,-45.0* SBS-TA, 2 min. 2,500 psicombination, loose4.0ftPly) BP-AA, #14, Trufast3” Metal Insulation Plate with Trufast #12 DP (steel SBS-TA or APP-APP-TA structuralconcretelaidSBS-AA only)or Trufast#14HD TA DekfastPLT-H-2-7/8orPTL-R-3plateswithDekfastDF-#12-PH3,DF- Min. 22 ga., type B,Oneormorelayers, #14-PH3 or DF-#15-PH3 fasteners or OMG 3 in. Galvalume Steel SBS-TA Grade 40 steel; 6 ftanycombination,Min.0.25-inchSECUROCK1perSBS-TA or(Optional)SBS- Plate, 3 in. Ribbed Galvalume Plate (Flat) or AccuTrac Flat Bottom SC-21.-52.5 or APP- 2 Plate with OMG #12 Roofgrip, #14 Roofgrip or OMG #15 Roofgrip span; 5/8” puddlemin.1.5”thick,loose Gypsum-FiberRoofBoard2.0ftAPP-TATAorAPP-TA TA fasteners or Trufast 3” Metal Insulation Plate with Trufast #12 DP, welds,6” o.c.laid Trufast#14HD orTrufast#15EHDfasteners DekfastPLT-H-2-7/8orPTL-R-3plateswithDekfastDF-#12-PH3,DF- Min. 22 ga., type B,Oneormorelayers, #14-PH3 or DF-#15-PH3 fasteners or OMG 3 in. Galvalume Steel SBS-TA Grade 40 steel; 6 ftanycombination,Min.0.25-inchDensDeck1perSBS-TA or(Optional)SBS- Plate, 3 in. Ribbed Galvalume Plate (Flat) or AccuTrac Flat Bottom SC-22.-60.0 or APP- 2 Plate with OMG #12 Roofgrip, #14 Roofgrip or OMG #15 Roofgrip span; 5/8” puddlePrime2.0ftAPP-TATAorAPP-TA min.1.5”thick,loose TA fasteners or Trufast 3” Metal Insulation Plate with Trufast #12 DP, welds,6” o.c.laid Trufast#14HD orTrufast#15EHDfasteners DekfastPLT-H-2-7/8orPTL-R-3plateswithDekfastDF-#12-PH3,DF- Min. 22 ga., type B,Oneormorelayers, #14-PH3 or DF-#15-PH3 fasteners or OMG 3 in. Galvalume Steel Min. 0.25-inch DensDeckSBS-TA Grade 40 steel; 6 ftanycombination,1perSBS-TA or(Optional)SBS- Plate, 3 in. Ribbed Galvalume Plate (Flat) or AccuTrac Flat Bottom Prime or SECUROCKor APP- SC-23.-67.5 2 Plate with OMG #12 Roofgrip, #14 Roofgrip or OMG #15 Roofgrip span; 5/8” puddlemin.1.5”thick,loose 1.6ftAPP-TATAorAPP-TA Gypsum-FiberRoofBoardTA fasteners or Trufast 3” Metal Insulation Plate with Trufast #12 DP, welds,6” o.c.laid Trufast#14HD orTrufast#15EHDfasteners NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 36of83 N EMO|etc. TABLE2B:STEELORSTRUCTURALCONCRETEDECKS–NEWCONSTRUCTION,REROOF(T EAR-O FF)OR RECOVER SYSTEMTYPEC-1:MECHANICALLYATTACHEDINSULATION,BONDEDROOFCOVER TopInsulationLayerRoofCover(Note15) SystemBase InsulationMDP Deck(Note1) No.Layer(Note13) (psf) TypeFasten (Note11)AttachBasePlyPlyCapPly (Optional if Min. 22 ga., type B,(Optional) One or(Optional if using AA Base)SBS-AA, Grade 33 steel ormore layers, anyMin. 0.5-inch SECUROCK1perusing AA OMG3-inchGalvalumeSteelPlatewithOMG #14HD SC-24.BP-AA, SBS-AA,SBS-TA,-75.0 2 min. 2,500 psicombination, loosePly) BP-AA, Gypsum-FiberRoofBoard1.8ft SBS-TA or APP-APP-TA structuralconcretelaidSBS-AA TA Min. 0.5-inch Structodek (Optional if Min. 22 ga., type B,High Density Fiberboard(Optional if Oneormorelayers,using AA Base)SBS-AA, Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #12 (steel only) 1per Grade 33 steel orRoof Insulation or min.using AA or #14 or Trufast3” Metal Insulation Plate with Trufast DP (steel SC-25.any combination,BP-AA, SBS-AA,SBS-TA,-82.5 2 min. 2,500 psi0.25-inchDensDeck,Dens1.3ftPly) BP-AA, only)or HD looselaidSBS-TA or APP-APP-TA Deck Prime or SECUROCK structuralconcreteSBS-AA TA Gypsum-FiberRoofBoard S ELF-A DHERING B ASE P LY: Min. 22 ga., type B,(Optional) One orSBS-SA, (Optional)SBS- OMG AccuTrac Flat Bottom Plate with #12 Roofgrip (steel only) or Grade 33 steel ormore layers, anyMin.1.5-inchH-Shieldor1perAPP-SA, OMG#14HeavyDuty,Trufast3”MetalInsulationPlatewithTrufast SC-26.SBS-SASA, SBS-TA,-45.0* 2 min. 2,500 psicombination, loosePolythermSBS-TA, 2.0ft #12DP(steelonly) orTrufast#14HD APP-TA structuralconcretelaidAPP-TA Min. 0.25-inch Dens Deck Min. 22 ga., type B, Oneormorelayers,Prime or SECUROCKSBS-CA1, Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14, OMG 3” Grade 33 steel or1per Galvalume Ribbed Plates with OMG #14 RoofGrip or Trufast 3” SC-27.any combination,Gypsum-Fiber Roof BoardSBS-SANoneSBS-CA2,-45.0* 2 min. 2,500 psi 2.0ft MetalInsulationPlateswithTrufast#14HD Fasteners looselaidoptionally primed withAPP-CA1 structuralconcrete POLYBRITE745orWB3000 Min. 0.25-inch Dens DeckSBS-SA, OMG 3 in. Galvalume Plate (non-ribbed) with #12 Roofgrip (steel Min. 22 ga., type B, Oneormorelayers,Prime or SECUROCK(Optional)SBS-APP-SA, only) or OMG #14 Heavy Duty, Dekfast Hex (aka, Dekfast PLT-H-2- Grade 33 steel or1per 7/8)withDekfast#12DP(steelonly)orDekfast#14,Trufast3” SC-28.any combination,Gypsum-Fiber Roof BoardSBS-SASA, SBS-TA orSBS-TA-45.0* 2 min. 2,500 psi2.0ft MetalInsulationPlatewithTrufast#12DP(steelonly)orTrufast#14 or APP- looselaidoptionally primed withAPP-TA structuralconcrete HD POLYBRITE745orWB3000TA Polygrip#14withPolygripHexPlateorDekfast#14withDekfastHex Min. 22 ga., type B,Oneormorelayers,Min.0.25-inchSECUROCK (aka, DekfastPLT-H-2-7/8)orDekfastGalvalumeSteel3”Round Grade 40 steel orany combination,Gypsum-Fiber Roof Board1per (aka, Dekfast PLT-R-3) or OMG #14 Roofgrip with OMG 3 in. Round SC-29.SBS-SANoneSBS-SA-45.0 2 Metal Plate,OMG3 in. RibbedGalvalume Plate(Flat) orAccutrac min. 2,500 psimin. 1-inch, looseoptionally primed with 2.0ft Flat Bottom Plate or Trufast #14 HD Fasteners with Trufast 3” Metal structuralconcretelaidPOLYBRITE745orWB3000 InsulationPlate Min. 22 ga., type B,Oneormorelayers,Min.0.25-inchDensDeck Polygrip#14 with Polygrip Hex Plate or Dekfast #14 with Dekfast Hex Grade 40 steel orany combination,Prime optionally primed1per (aka,DekfastPLT-H-2-7/8) orOMG #14Roofgrip withOMG 3in. SC-30.SBS-SANoneSBS-SA-45.0 2 RoundMetalPlateorAccutracFlatBottomPlateorTrufast#14HD min. 2,500 psimin. 1-inch, loosewith POLYBRITE 745 or2.0ft FastenerswithTrufast3”MetalInsulationPlate structuralconcretelaidWB3000 NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 37of83 N EMO|etc. TABLE2B:STEELORSTRUCTURALCONCRETEDECKS–NEWCONSTRUCTION,REROOF(T EAR-O FF)OR RECOVER SYSTEMTYPEC-1:MECHANICALLYATTACHEDINSULATION,BONDEDROOFCOVER TopInsulationLayerRoofCover(Note15) SystemBase InsulationMDP Deck(Note1) No.Layer(Note13) (psf) TypeFasten (Note11)AttachBasePlyPlyCapPly SBS-SA, Polygrip #14 or Polygrip #15 with Polygrip Hex Plate or Dekfast DF- Min. 22 ga., type B,Oneormorelayers,Min.0.25-inchSECUROCK(Optional when APP-SA, #14 or DF-#15 with Dekfast Hex (aka, DekfastPLT-H-2-7/8) or OMG Grade 40 steel orany combination,Gypsum-Fiber Roof Board1perusing torch- #14 Roofgrip or #15 Roofgrip with OMG 3 in. Round Metal Plate or SC-31.SBS-SA-45.0 SBS-TA 2 min. 2,500 psimin. 1-inch, looseoptionally primed withapplied Cap Ply) 1.8ft Accutrac Flat Bottom Plate or Trufast #14 HD or Trufast #15 EHD orAPP- structuralconcretelaidPOLYBRITE745orWB3000SBS-TA,APP-TA Fastenerswith Trufast3”MetalInsulationPlate TA SBS-SA, Min. 22 ga., type B,Oneormorelayers,Min.0.25-inchDensDeck(Optional when APP-SA, OMG#14Roofgrip or#15Roofgrip withOMG 3in.Round Metal Grade 40 steel orany combination,Prime optionally primed1perusing torch- SC-32.PlateorTrufast#14HDorTrufast#15EHDFastenerswithTrufast3”SBS-SA-45.0 SBS-TA 2 min. 2,500 psimin. 1-inch, loosewith POLYBRITE 745 or 1.8ftapplied Cap Ply) MetalInsulationPlate orAPP- structuralconcretelaidWB3000SBS-TA,APP-TA TA Min. 22 ga., type B,(Optional) One orSBS-SA, (Optional)SBS- Grade 33 steel ormore layers, anyMin.1.5-inchH-Shieldor1perAPP-SA, DekfastHex(aka,DekfastPLT-H-2-7/8)withDekfast#12DP(steel SA, SBS-TA, SC-33.SBS-SA-60.0 2 only)or Dekfast #14 min. 2,500 psicombination, loosePolythermSBS-TA, 2.0ft APP-TA structuralconcretelaidAPP-TA Min. 0.25-inch Dens Deck OMG 3 in. Galvalume Plate (non-ribbed) with #12 Roofgrip (steel Min. 22 ga., type B, Oneormorelayers,Prime or SECUROCK SBS-TA only) or OMG #14 Heavy Duty, Dekfast Hex (aka, Dekfast PLT-H-2- Grade 40 steel or1per(Optional)SBS- 7/8)withDekfast#12DP(steelonly)orDekfast#14,Trufast3” SC-34.any combination,Gypsum-Fiber Roof BoardSBS-SAor APP--60.0 2 min. 2,500 psi 1.6ftTAorAPP-TA MetalInsulationPlatewithTrufast#12DP(steelonly)orTrufast#14 looselaidoptionally primed withTA structuralconcrete HD POLYBRITE745orWB3000 Min. 1.5-inch ACFoam II, ACFoam III, EnergyGuard Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or Dekfast Galvalume Steel PolyisoInsulation,ENRGY3, Min. 22 ga., type B,(Optional) One orSBS-SA, 3” Round Insulation Plate (aka, Dekfast PLT-R-3) with Dekfast #12 (Optional)SBS- ENRGY 3 CGF, H-Shield, H- Grade 33 steel ormore layers, any1perAPP-SA, (steel only) or Dekfast #14, OMG 3 in. Galvalume Plate (non-ribbed) ShieldCG,ISO95+GL,SBS-SA-67.5* SC-35.SA, SBS-TA, 2 or OMG AccuTrac Plate with #12 Roofgrip (steel only) or OMG #14 min. 2,500 psicombination, loose1.3ftSBS-TA, Multi-Max FA3, PolythermAPP-TA Heavy Duty or Trufast 3” Metal Insulation Plate with Trufast #12 DP structuralconcretelaidAPP-TA or Ultra-Max optionally (steelonly) orTrufast#14HD primedwithPOLYBRITE745 orWB3000 Min. 0.25-inch Dens Deck OMG 3 in. Galvalume Plate (non-ribbed) with #12 Roofgrip (steel Min. 22 ga., type B, Oneormorelayers,Prime or SECUROCKSBS-TA only) or OMG #14 Heavy Duty, Dekfast Hex (aka, Dekfast PLT-H-2- Grade 40 steel or1per(Optional)SBS- 7/8)withDekfast#12DP(steelonly)orDekfast#14,Trufast3” SC-36.SBS-SA-72.5 any combination,Gypsum-Fiber Roof Boardor APP- 2 min. 2,500 psi1.3ftTAorAPP-TA MetalInsulationPlatewithTrufast#12DP(steelonly)orTrufast#14 looselaidoptionally primed withTA structuralconcrete HD POLYBRITE745orWB3000 Min. 22 ga., type B,(Optional) One or Grade 33 steel ormore layers, any Min. 0.5-inch SECUROCK1per(Optional)SBS- OMG3-inchGalvalumeSteelPlatewithOMG #14HD SC-37.SBS-SASBS-TA-75.0 2 min. 2,500 psicombination, looseGypsum-FiberRoofBoard1.8ftTA structuralconcretelaid NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 38of83 N EMO|etc. TABLE2B:STEELORSTRUCTURALCONCRETEDECKS–NEWCONSTRUCTION,REROOF(T EAR-O FF)OR RECOVER SYSTEMTYPEC-1:MECHANICALLYATTACHEDINSULATION,BONDEDROOFCOVER TopInsulationLayerRoofCover(Note15) SystemBase InsulationMDP Deck(Note1) No.Layer(Note13) (psf) TypeFasten (Note11)AttachBasePlyPlyCapPly Polygrip #14 or Polygrip #15 with Polygrip Hex Plate or Dekfast DF- Min. 22 ga., type B,Oneormorelayers,Min.0.25-inchSECUROCK #14 or DF-#15 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or OMG Grade 40 steel orany combination,1per(Optional)SBS-SBS-TA, Gypsum-Fiber Roof Board #14 Roofgrip or #15 Roofgrip with OMG 3 in. Round Metal Plate or SC-38.SBS-SA-90.0 2 min. 2,500 psimin. 1-inch, loose optionally primed with1.0ftTA,APP-TAAPP-TA Accutrac Flat Bottom Plate or Trufast #14 HD or Trufast #15 EHD structuralconcretelaidPOLYBRITE745orWB3000 Fastenerswith Trufast3”MetalInsulationPlate Polygrip#14 or Polygrip #15 with Polygrip Hex Plate or Dekfast DF- Min. 22 ga., type B,Oneormorelayers,Min.0.25-inchDensDeck #14 or DF-#15 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or OMG Grade 40 steel orany combination,Prime optionally primed1per(Optional)SBS-SBS-TA, #14 Roofgrip or #15 Roofgrip with OMG 3 in. Round Metal Plate or SC-39.SBS-SA-97.5 2 min. 2,500 psimin. 1-inch, loosewith POLYBRITE 745 orTA,APP-TAAPP-TA 1.0ft Trufast #14 HD or Trufast #15 EHD Fasteners with Trufast 3” Metal structuralconcretelaidWB3000 InsulationPlate H YBRID S YSTEMSWITH S ELF-A DHERING APPB ASE P LY: Min. 22 ga., type B,(Optional) One or OMG AccuTrac Flat Bottom Plate with #12 Roofgrip (steel only) or Grade 33 steel ormore layers, anyMin.1.5-inchH-Shieldor1per(Optional) APP- OMG #14 Heavy Duty, Trufast 3” Metal Insulation Plate with Trufast SC-40.APP-SA-HAPP-TA-45.0* 2 min. 2,500 psicombination, loosePolytherm2.0ftTA #12DP(steelonly) orTrufast#14HD structuralconcretelaid H YBRID S YSTEMSWITH S ELF-A DHERING SBSB ASE P LY: Min. 22 ga., type B,(Optional) One or OMG AccuTrac Flat Bottom Plate with #12 Roofgrip (steel only) or Grade 33 steel ormore layers, anyMin.1.5-inchH-Shieldor1per(Optional)SBS- OMG#14HeavyDuty,Trufast3”MetalInsulationPlatewithTrufast SC-41.SBS-SA-HSBS-TA-45.0* 2 min. 2,500 psicombination, loosePolythermH2.0ftTA #12DP(steelonly) orTrufast#14HD structuralconcretelaid Polygrip#14withPolygripHexPlateorDekfast#14withDekfastHex Min. 22 ga., type B,Oneormorelayers,Min.0.25-inchSECUROCK (aka, DekfastPLT-H-2-7/8)orDekfastGalvalumeSteel3”Round Grade 40 steel orany combination,Gypsum-Fiber Roof Board1per(Optional)SBS- (aka, Dekfast PLT-R-3) or OMG #14 Roofgrip with OMG 3 in. Round SC-42.SBS-SA-HSBS-TA-45.0 2 Metal Plate,OMG3 in. RibbedGalvalume Plate(Flat) orAccutrac min. 2,500 psimin. 1-inch, looseoptionally primed with2.0ftTA Flat Bottom Plate or Trufast #14 HD Fasteners with Trufast 3” Metal structuralconcretelaidPOLYBRITE745orWB3000 InsulationPlate Min. 22 ga., type B,Oneormorelayers,Min.0.25-inchDensDeck Polygrip#14withPolygripHexPlateorDekfast#14withDekfastHex Grade 40 steel orany combination,Prime optionally primed1per(Optional)SBS- (aka,DekfastPLT-H-2-7/8) orOMG #14RoofgripwithOMG3in. SC-43.SBS-SA-HSBS-TA-45.0 2 RoundMetalPlateorAccutracFlatBottomPlateorTrufast#14HD min. 2,500 psimin. 1-inch, loosewith POLYBRITE 745 or2.0ftTA FastenerswithTrufast3”MetalInsulationPlate structuralconcretelaidWB3000 Min. 22 ga., type B,(Optional) One orMin. 1.5-inch H-Shield or Grade 33 steel ormore layers, anyPolytherm optionally1per(Optional)SBS- Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast#12 DP (steel SC-44.SBS-SA-HSBS-TA-60.0 2 only)or Dekfast #14 min. 2,500 psicombination, looseprimedwithPOLYBRITE7452.0ftTA structuralconcretelaidorWB3000 Min. 0.25-inch Dens Deck OMG 3 in. Galvalume Plate (non-ribbed) with #12 Roofgrip (steel Min. 22 ga., type B, Oneormorelayers,Prime or SECUROCK only) or OMG #14 Heavy Duty, Dekfast Hex (aka, Dekfast PLT-H-2- Grade 40 steel or1per(Optional)SBS- 7/8) with Dekfast #12 DP (steel only) or Dekfast #14, Trufast 3” SC-45.any combination,Gypsum-Fiber Roof BoardSBS-SA-HSBS-TA-60.0 2 min. 2,500 psi1.6ftTA MetalInsulationPlatewithTrufast#12DP(steelonly)orTrufast#14 looselaid optionally primed with structuralconcrete HD POLYBRITE745orWB3000 NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 39of83 N EMO|etc. TABLE2B:STEELORSTRUCTURALCONCRETEDECKS–NEWCONSTRUCTION,REROOF(T EAR-O FF)OR RECOVER SYSTEMTYPEC-1:MECHANICALLYATTACHEDINSULATION,BONDEDROOFCOVER TopInsulationLayerRoofCover(Note15) SystemBase InsulationMDP Deck(Note1) No.Layer(Note13) (psf) TypeFasten (Note11)AttachBasePlyPlyCapPly Min. 1.5-inch ACFoam II, ACFoam III, EnergyGuard Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or Dekfast Galvalume Steel PolyisoInsulation,ENRGY3, Min. 22 ga., type B,(Optional) One or 3” Round Insulation Plate (aka, Dekfast PLT-R-3) with Dekfast #12 ENRGY 3 CGF, H-Shield, H- Grade 33 steel ormore layers, any1per(Optional)SBS- (steel only) or Dekfast #14, OMG 3 in. Galvalume Plate (non-ribbed) SC-46.SBS-SA-HSBS-TA-67.5* ShieldCG,ISO95+GL, 2 or OMG AccuTrac Plate with #12 Roofgrip (steel only) or OMG #14 min. 2,500 psicombination, loose1.3ftTA Multi-Max FA3, Polytherm Heavy Duty or Trufast 3” Metal Insulation Plate with Trufast #12 DP structuralconcretelaid or Ultra-Max optionally (steelonly) orTrufast#14HD primedwithPOLYBRITE745 orWB3000 Min. 0.25-inch Dens Deck OMG 3 in. Galvalume Plate (non-ribbed) with #12 Roofgrip (steel Min. 22 ga., type B, Oneormorelayers,Prime or SECUROCK only) or OMG #14 Heavy Duty, Dekfast Hex (aka, Dekfast PLT-H-2- Grade 40 steel or1per(Optional)SBS- 7/8)withDekfast#12DP(steelonly)orDekfast#14,Trufast3” SC-47.any combination,Gypsum-Fiber Roof BoardSBS-SA-HSBS-TA-72.5 2 min. 2,500 psi1.3ftTA MetalInsulationPlatewithTrufast#12DP(steelonly)orTrufast#14 looselaidoptionally primed with structuralconcrete HD POLYBRITE745orWB3000 Min. 22 ga., type B,(Optional) One or Grade 33 steel ormore layers, anyMin. 0.5-inch SECUROCK1per(Optional)SBS- OMG3-inchGalvalumeSteelPlatewithOMG #14HD SC-48.SBS-SA-HSBS-TA-75.0 2 min. 2,500 psicombination, looseGypsum-FiberRoofBoard1.8ftTA structuralconcretelaid Polygrip #14 or Polygrip #15 with Polygrip Hex Plate or Dekfast DF- Min. 22 ga., type B,Oneormorelayers,Min.0.25-inchSECUROCK #14 or DF-#15 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or OMG Grade 40 steel orany combination,1per(Optional)SBS- Gypsum-Fiber Roof Board #14 Roofgrip or #15 Roofgrip with OMG 3 in. Round Metal Plate or SC-49.SBS-SA-HSBS-TA-90.0 2 min. 2,500 psimin. 1-inch, looseTA optionally primed with1.0ft Accutrac Flat Bottom Plate or Trufast #14 HD or Trufast #15 EHD structuralconcretelaidPOLYBRITE745orWB3000 Fastenerswith Trufast3”MetalInsulationPlate Polygrip #14 or Polygrip #15 with Polygrip Hex Plate or Dekfast DF- Min. 22 ga., type B,Oneormorelayers,Min.0.25-inchDensDeck #14 or DF-#15 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or OMG Grade 40 steel orany combination,Prime optionally primed1per(Optional)SBS- #14 Roofgrip or #15 Roofgrip with OMG 3 in. Round Metal Plate or SC-50.SBS-SA-HSBS-TA-97.5 2 min. 2,500 psimin. 1-inch, loosewith POLYBRITE 745 or 1.0ftTA Trufast #14 HD or Trufast #15 EHD Fasteners with Trufast 3” Metal structuralconcretelaidWB3000 InsulationPlate C OLD-A PPLIED B ASE P LY: Min. 22 ga., type B, Oneormorelayers,Min. 0.25-inch Dens DeckSBS-CA1, Dekfast Galvalume Steel Hex with Dekfast #14, OMG 3” Galvalume Grade 33 steel or1perSBS-CA1,(Optional)SBS- Ribbed Plates with OMG #14 RoofGrip or Trufast3” Metal Insulation SBS-CA2, SC-51.any combination,Prime or SECUROCK-45.0* 2 min. 2,500 psiSBS-CA2CA1,SBS-CA2 2.0ft Plateswith Trufast#14HD Fasteners looselaidGypsum-FiberRoofBoardAPP-CA1 structuralconcrete NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 40of83 N EMO|etc. TABLE2C:STEELORSTRUCTURALCONCRETEDECKS–NEWCONSTRUCTION,REROOF(T EAR-O FF)OR RECOVER SYSTEMTYPED-2:INSULATED,MECHANICALLYATTACHEDBASESHEET,BONDEDROOFCOVER InsulationLayer(s) BaseSheetRoofCover(Note15) Deck SystemMDP (Note13) No.(psf) (Note1) TypeAttachTypeFasten(Note11)AttachBasePlyCapPly A SPHALT-OR T ORCH-A PPLIED B ASE P LY: Elastobase,12-inch o.c. at 4-inch lap and Roofgrip#14withOMGFlatBottomPlates Min.22ga.,typeB,GradeOneormore(Optional) BP-AA, Prelim.Elastobase P,18-inch o.c. at two, equallySBS-AA, SBS- (square), Dekfast #14 with Dekfast Hex SC-52.33 steel or min. 2,500 psilayers, anySBS-AA, SBS-TA or-45.0* (aka, Dekfast PLT-H-2-7/8) or Trufast #14 AttachedElastoventorJMspaced, staggered centerTA,APP-TA structural concretecombinationAPP-TA HDwithTrufast3”MetalInsulationPlate Perma-Ply28rows Elastobase, Elastobase P, Elastovent, Polyglass12-inch o.c. at 4-inch lap and Roofgrip#14withOMGFlatBottomPlates Min.22ga.,typeB,GradeOneormore(Optional) BP-AA, Prelim.G2Base,CertainTeed12-inch o.c. at two, equallySBS-AA, SBS- (square), Dekfast #14 with Dekfast Hex SC-53.33 steel or min. 2,500 psilayers, anySBS-AA, SBS-TA or-52.5 (aka, Dekfast PLT-H-2-7/8) or Trufast #14 AttachedGlasbase, Firestonespaced, staggered centerTA,APP-TA structural concretecombinationAPP-TA HDwithTrufast3”MetalInsulationPlate MB Base, JM Perma-rows Ply 28 or GAFGLAS #75 12-inch o.c. at 4-inch lap and Min.22ga.,typeB,GradeOneormoreElastobase,(Optional) BP-AA, Prelim.12-inch o.c.at two, equallySBS-AA, SBS- Roofgrip #12 (steel only) or #14 with OMG 33 steel or min. 2,500 psilayers, any SC-54.ElastobasePorSBS-AA, SBS-TA or-60.0 FlatBottom Plates(square) Attachedspaced, staggered centerTA,APP-TA structuralconcretecombinationElastoventAPP-TA rows 12-inch o.c. at the 4-inch lap Min.22ga.,typeB,GradeOneormore(Optional) BP-AA, Dekfast #14 with Dekfast Hex (aka, Dekfast Prelim.and 18-inch o.c. at two,SBS-AA, SBS- PLT-H-2-7/8) or OMG Roofgrip #14 OMG SC-55.33 steel or min. 2,500 psilayers, anyPolybond,PolyflexSBS-AA, SBS-TA or-112.5 Attachedequally spaced, staggeredTA,APP-TA FlatBottom Plates structuralconcretecombination APP-TA centerrows S ELF-A DHERING B ASE P LY: 12-inch o.c. at 4-inch lap and Roofgrip#14withOMGFlatBottomPlates Min.22ga.,typeB,GradeOneormoreSBS-SA, APP- Elastobase or Prelim.12-inch o.c. at two, equally (square), Dekfast #14 with Dekfast Hex SC-56.33 steel or min. 2,500 psilayers, anyElastobasePwithSBS-SASA, SBS-TA or-52.5* (aka, Dekfast PLT-H-2-7/8) or Trufast #14 Attachedspaced, staggered center structuralconcretecombinationAPP-TA polytopsurface HDwithTrufast3”MetalInsulationPlate rows 12-inch o.c. at 4-inch lap and Min.22ga.,typeB,GradeOneormoreSBS-SA, APP- Elastobase or Prelim.12-inch o.c. at two, equally Roofgrip #12 (steel only) or #14 with OMG SC-57.33 steel or min. 2,500 psilayers, anyElastobasePwithSBS-SASA, SBS-TA or-60.0* FlatBottom Plates(square) Attachedspaced, staggered center structuralconcretecombinationpolytopsurfaceAPP-TA rows H YBRID S YSTEMSWITH S ELF-A DHERING APPB ASE P LY: 12-inch o.c. at 4-inch lap and Roofgrip#14withOMGFlatBottomPlates Min.22ga.,typeB,GradeOneormore Elastobase or Prelim.12-inch o.c. at two, equally (square), Dekfast#14 with Dekfast Hex SC-58.33 steel or min. 2,500 psilayers, anyElastobasePwithAPP-SA-HAPP-TA-52.5* (aka, Dekfast PLT-H-2-7/8) or Trufast #14 Attachedspaced, staggered center structuralconcretecombinationpolytopsurface HDwithTrufast3”MetalInsulationPlate rows NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 41of83 N EMO|etc. TABLE2C:STEELORSTRUCTURALCONCRETEDECKS–NEWCONSTRUCTION,REROOF(T EAR-O FF)OR RECOVER SYSTEMTYPED-2:INSULATED,MECHANICALLYATTACHEDBASESHEET,BONDEDROOFCOVER InsulationLayer(s) BaseSheetRoofCover(Note15) Deck SystemMDP (Note13) No.(psf) (Note1) TypeAttachTypeFasten(Note11)AttachBasePlyCapPly 12-inch o.c. at 4-inch lap and Min.22ga.,typeB,GradeOneormoreElastobase or Prelim.12-inch o.c. at two, equally Roofgrip #12 (steel only) or #14 with OMG 33 steel or min. 2,500 psilayers, anyElastobasePwith SC-59.APP-SA-HAPP-TA-60.0* FlatBottom Plates(square) Attachedspaced, staggered center structuralconcretecombinationpolytopsurface rows H YBRID S YSTEMSWITH S ELF-A DHERING SBSB ASE P LY: 12-inch o.c. at min. 4-inch lap Roofgrip#14withOMGFlatBottomPlates Min.22ga.,typeB,GradeOneormoreElastobase or Prelim.and 12-inch o.c. at two, (square), Dekfast#14 with Dekfast Hex 33 steel or min. 2,500 psilayers, anyElastobasePwith SC-60.SBS-SA-HSBS-TA-52.5* (aka, Dekfast PLT-H-2-7/8) or Trufast #14 Attachedequally spaced, staggered structuralconcretecombinationpolytopsurface HDwithTrufast3”MetalInsulationPlate centerrows 12-inch o.c.at min. 4-inch lap Min.22ga.,typeB,GradeOneormore Elastobase or Prelim.and 12-inch o.c. at two, Roofgrip #12 (steel only) or #14 with OMG SC-61.33 steel or min. 2,500 psilayers, anyElastobasePwithSBS-SA-HSBS-TA-60.0* FlatBottom Plates(square) Attachedequally spaced, staggered structuralconcretecombination polytopsurface centerrows C OLD-A PPLIED B ASE P LY: Min.22ga.,typeB,GradeOneormore12-inch o.c. at 4-inch lap and Loose(Optional)SBS-CA1,SBS-CA1, SBS- Trufast#12DP(steelonly),#14HDor#15 33 steel or min. 2,500 psilayers, any12-inch o.c. at one staggered SC-62.Elastobase-45.0* EHDwithTrufast3”MetalInsulationPlate laidSBS-CA2CA2,APP-CA1 structuralconcretecombinationcenterrow Min.22ga.,typeB,GradeOneormore12-inch o.c.at min. 4-inch lap LooseSBS-CA1, APP- Trufast#12DP(steelonly),#14HDor#15 SC-63.33 steel or min. 2,500 psilayers, anyElastoventand 12-inch o.c. at one(Optional)SBS-CA1-45.0* EHDwithTrufast3”MetalInsulationPlate CA1 laid structuralconcretecombinationstaggeredcenterrow 12-inch o.c. at 4-inch lap and Min.22ga.,typeB,GradeOneormore Loose12-inch o.c. at two, equally(Optional)SBS-CA1,SBS-CA1, SBS- Trufast#12DP(steelonly),#14HDor#15 33 steel or min. 2,500 psilayers, any SC-64.Elastobase-67.5 EHDwithTrufast3”MetalInsulationPlate laidspaced, staggered centerSBS-CA2CA2,APP-CA1 structuralconcretecombination rows 12-inch o.c.at min. 4-inch lap Min.22ga.,typeB,GradeOneormore Looseand 12-inch o.c. at two,SBS-CA1, APP- Trufast#12DP(steelonly),#14HDor#15 SC-65.33 steel or min. 2,500 psilayers, anyElastovent(Optional)SBS-CA1-67.5 EHDwithTrufast3”MetalInsulationPlate laidequally spaced, staggeredCA1 structuralconcretecombination centerrows Min.22ga.,typeB,GradeOneormore6-incho.c.atmin.4-inchlap(Optional) Elastoflex Trufast #12 DP (steel only) or Trufast #14 Loose- HD (steel or concrete) with Trufast 3” 40 steel or min. 2,500 psilayers, anyand 6-inch o.c. at oneS6 applied in PG350 SC-66.ElastoflexS6SBS-CA1-75.0* laid MetalInsulation Plate structuralconcretecombinationstaggeredcenterrowat1.5-2.0gal/square 12-inch o.c. at min. 4-inch lap Min. 22 ga., type B, GradeOneormore(Optional) Elastoflex Trufast#12 DP (steel only) or Trufast #14 Loose-and 12-inch o.c. at two, HD (steel or concrete) with Trufast 3” SC-67.40 steel or min. 2,500 psilayers, anyElastoflexS6S6 applied in PG350SBS-CA1-90.0* laidequally spaced, staggered MetalInsulation Plate structuralconcretecombination at1.5-2.0gal/square centerrows NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 42of83 N EMO|etc. TABLE2D:STEELORSTRUCTURALCONCRETEDECKS–NEWCONSTRUCTION,REROOF(T EAR-O FF)OR RECOVER SYSTEMTYPED-2:INSULATED,MECHANICALLYATTACHEDVELOCIFLEX,BONDEDROOFCOVER InsulationLayer(s) BaseSheetRoofCover(Note15) Deck SystemMDP (Note13) No. (psf) (Note1) TypeAttachTypeFasten(Note11)AttachBasePlyCapPly A SPHALT-OR T ORCH-A PPLIED B ASE P LY: Min. 22 ga., type B, 33Oneormore12-inch o.c.within the 5-inch Trufast #15 EHD (steel only) or Trufast #14 HD (concrete Prelim.(Optional) only) with Trufast 2.4” Scoop Seam Plates or Trufast 2.75” ksi steel or min. 2,500layers, anywide, torch-sealed or heat- SC-68.ElastoflexS6SBS-TA-45.0 AttachedSBS-TA BarbedMetalSeamPlates psistructuralconcretecombinationweldedsidelaps Min. 22 ga., type B, 33Oneormore6-incho.c.withinthe5-inch Prelim.(Optional) Trufast#15EHD(steelonly)orTrufast#14HD(concrete ksi steel or min. 2,500layers, anywide, torch-sealed or heat- SC-69.ElastoflexS6SBS-TA-60.0 only)withTrufast2.75”BarbedMetalSeamPlates AttachedSBS-TA psistructuralconcretecombinationweldedsidelaps Min. 22 ga., type B, Oneormore18-inch o.c.within the 5-inch Grade40steelormin.Prelim.(Optional)SBS-TA Trufast#15EHD(steelonly)orTrufast#14HD(concrete SC-70.ElastoflexS6HP-60.0 layers, anywide, torch-sealed or heat- only)withTrufast2.75”BarbedMetalSeamPlates 2,500 psi structuralAttachedSBS-TA(D6164only) combinationweldedsidelaps concrete Min. 22 ga., type B, 33Oneormore12-inch o.c. within the 5-inch Prelim.(Optional)SBS-TA Trufast#15EHD(steelonly)orTrufast#14HD(concrete SC-71.ksi steel or min. 2,500layers, anyElastoflexS6HPwide, torch-sealed or heat--82.5 only)withTrufast2.75”BarbedMetalSeamPlates AttachedSBS-TA(D6164only) psistructuralconcretecombinationweldedsidelaps Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast2.4” Barbed Metal Seam Plates, Trufast Min. 22 ga., type B, 33Oneormore12-inch o.c. within the 5-inch 2.4” Scoop Seam Plates or Trufast 2.75” Barbed Metal Prelim.(Optional)SBS-TA Seam Plates or Dekfast #15 with Dekfast Galvalume Steel SC-72.ksi steel or min. 2,500layers, anyElastoshieldHTwide, torch-sealed or heat--82.5 AttachedSBS-TA (D6164only) 1-1/2” x 2-3/4” Oval Barbed Plate (aka, Dekfast PLT-O2- psistructuralconcretecombinationweldedsidelaps 3/4-12B) or Dekfast Galvalume Steel 2-3/8” Round BarbedPlate(aka,Dekfast PLT-R-2-3/8-6B) Oneormore Min.22ga.,typeB,Prelim.12-inch o.c. within the 5-inch(Optional)SBS-TA, APP- Dekfast #15 HS with Dekfast Galvalume Steel 2-3/8” SC-73.layers, anyPolyflex-82.5 RoundBarbedPlate(aka,DekfastPLT-R-2-3/8-6B) Grade80steelAttachedwide,torch-sealedsidelapAPP-TATA combination Min. 22 ga., type B, Oneormore Grade80steelormin.Prelim.Polybond or12-inch o.c. within the 6-inch(Optional)SBS-TA, APP- Trufast #15 EHD (steel only) or Trufast #14 HD (concrete SC-74.layers, any-82.5 only)withTrufast2.4in.Barbed SeamPlates 2,500 psi structuralAttachedPolyflexwide,torch-sealedsidelapAPP-TATA combination concrete Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2.4” Barbed Metal Seam Plates, Trufast Min. 22 ga., type B, 40Oneormore6-incho.c.withinthe5-inch 2.4” Scoop Seam Plates or Trufast 2.75” Barbed Metal Prelim.(Optional)SBS-TA Seam Plates or Dekfast #15 with Dekfast Galvalume Steel SC-75.ksi steel or min. 2,500layers, anyElastoshieldHTwide, torch-sealed or heat--97.5 AttachedSBS-TA (D6164only) 1-1/2” x 2-3/4” Oval Barbed Plate (aka, Dekfast PLT-O2- psistructuralconcretecombinationweldedsidelaps 3/4-12B) or Dekfast Galvalume Steel 2-3/8” Round BarbedPlate(aka,DekfastPLT-R-2-3/8-6B) NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 43of83 N EMO|etc. TABLE2D:STEELORSTRUCTURALCONCRETEDECKS–NEWCONSTRUCTION,REROOF(T EAR-O FF)OR RECOVER SYSTEMTYPED-2:INSULATED,MECHANICALLYATTACHEDVELOCIFLEX,BONDEDROOFCOVER InsulationLayer(s) BaseSheetRoofCover(Note15) Deck SystemMDP (Note13) No.(psf) (Note1) TypeAttachTypeFasten(Note11)AttachBasePlyCapPly Min. 22 ga., type B, Oneormore6-incho.c.withinthe5-inch Grade40steelormin.Prelim.(Optional)SBS-TA Trufast#15EHD(steelonly)orTrufast#14HD(concrete SC-76.layers, anyElastoflexS6HPwide, torch-sealed or heat--135.0 only)withTrufast2.75”BarbedMetalSeamPlates 2,500 psi structuralAttachedSBS-TA(D6164only) combinationweldedsidelaps concrete C OLD-A PPLIED B ASE P LY: (Optional) Min. 22 ga., type B, 40Oneormore18-inch o.c. within the 5-inchElastoflex S6 Prelim. Trufast#15EHD(steelonly)orTrufast#14HD(concrete ksi steel or min. 2,500layers, anyElastoflexS6HPwide, torch-sealed or heat-applied inSBS-CA1-60.0 only)withTrufast2.75”BarbedMetalSeamPlates Attached psistructuralconcretecombinationweldedsidelapsPG350at1.5- SC-77. 2.0gal/square Note:When extrapolating base sheet attachment for this system for elevated pressure zones, any additional fastener rows installed in the center of the sheet shall be stripped-in with minimum6-inchwidestripsoftorch-applied,sand-top-surfaced,PolyglassSBSmodifiedbitumenmembranepriortoplacementofsubsequentBasePlyorCapPlymembranesin PG350adhesive. (Optional) Min. 22 ga., type B, 40Oneormore12-inch o.c. within the 5-inchElastoflex S6 Prelim. Trufast#15EHD(steelonly)orTrufast#14HD(concrete ksi steel or min. 2,500layers, anyElastoflexS6HPwide, torch-sealed or heat-applied inSBS-CA1-82.5 only)withTrufast2.75”BarbedMetalSeamPlates Attached psistructuralconcretecombinationweldedsidelapsPG350at1.5- SC-78. 2.0gal/square When extrapolating base sheet attachment for this system for elevated pressure zones, any additional fastener rows installed in the center of the sheet shall be stripped-in with Note: minimum6-inchwidestripsoftorch-applied,sand-top-surfaced,PolyglassSBSmodifiedbitumenmembranepriortoplacementofsubsequentBasePlyorCapPlymembranesin PG350adhesive. NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 44of83 N EMO|etc. TABLE3A:STRUCTURALCONCRETEDECKS;M IN.2,500 PSI–NEWCONSTRUCTION OR REROOF(T EAR-O FF) SYSTEMTYPEA-1:BONDEDINSULATION,BONDEDROOFCOVER R EFER TO N OTE 16 FOR VAPORBARRIEROPTIONS BaseInsulationLayerTopInsulationLayerRoofCover(Note15) Deck System*MDP Primer AttachAttach No. (psf) (Note1) TypeTypeBasePlyPlyCapPly (Notes6,7,8)(Notes6,7,8) A SPHALTOR T ORCH A PPLIED B ASE P LY: StructuralMin. 2-inch Polytherm, ACFoam II,Min.0.25-inchSECUROCK C-1NoneD-ISD-ISBP-AA,SBS-AA(Optional)BP-AA,SBS-AASBS-AA-225.0 concretePolythermHor H-ShieldGypsum-FiberRoofBoard (Optional) Min. 1.5-inch Polytherm, StructuralMin.0.25-inchDensDeckSBS-TA, APP-(Optional) SBS-TA, APP- ACFoam II, Polytherm G, ACFoam III, C-2NoneD-ISD-ISSBS-TA,APP-TA-282.5 concretePrimeTATA PolythermH, H-Shield Min.0.25-inchSECUROCK (Optional) Min. 1.5-inch Polytherm, StructuralGypsum-FiberRoofBoardorSBS-TA, APP-(Optional) SBS-TA, APP- ACFoam II, Polytherm G, ACFoam III, C-3NoneD-ISD-ISSBS-TA,APP-TA-322.5 concreteDEXcellFA Glass Mat RoofTATA PolythermH, H-Shield Board StructuralMin. 2-inch Polytherm, ACFoam II,Min.0.25-inchSECUROCK C-4NoneOB500 OB500BP-AA,SBS-AA(Optional)BP-AA,SBS-AASBS-AA-225.0 concretePolythermHor H-ShieldGypsum-FiberRoofBoard (Optional) Min. 1.5-inch Polytherm, StructuralMin.0.25-inchDensDeckSBS-TA, APP-(Optional) SBS-TA, APP- C-5NoneACFoam II, Polytherm G, ACFoam III,OB500OB500SBS-TA,APP-TA-282.5 concretePrimeTATA PolythermH, H-Shield Min.0.25-inchSECUROCK (Optional) Min. 1.5-inch Polytherm, StructuralGypsum-FiberRoofBoardorSBS-TA, APP-(Optional) SBS-TA, APP- C-6NoneACFoam II, Polytherm G, ACFoam III,OB500OB500SBS-TA,APP-TA-322.5 concreteTATA DEXcellFA Glass Mat Roof PolythermH, H-Shield Board StructuralMin. 2-inch Polytherm, ACFoam II,M-OSFA orMin.0.25-inchSECUROCKM-OSFA or C-7NoneBP-AA,SBS-AA(Optional)BP-AA,SBS-AASBS-AA-225.0 concretePolythermHor H-ShieldM-PG1M-PG1 Gypsum-FiberRoofBoard (Optional) Min. 1.5-inch Polytherm, StructuralM-OSFA orMin.0.25-inchDensDeckM-OSFA orSBS-TA, APP-(Optional) SBS-TA, APP- C-8NoneACFoam II, Polytherm G, ACFoam III,SBS-TA,APP-TA-282.5 concrete M-PG1PrimeM-PG1TATA PolythermH, H-Shield Min.0.25-inchSECUROCK (Optional) Min. 1.5-inch Polytherm, StructuralM-OSFA orM-OSFA orSBS-TA, APP-(Optional) SBS-TA, APP- Gypsum-FiberRoofBoardor C-9NoneACFoam II, Polytherm G, ACFoam III,SBS-TA,APP-TA-322.5 concreteM-PG1M-PG1TATA DEXcell FA Glass Mat Roof PolythermH, H-Shield Board Min.1.5-inchUltra-MaxorMulti-MaxFA-3, Structuralmin. 1.3-inch Polytherm G, ACFoam III orMin.0.25-inchSECUROCK C-10NoneCR-20CR-20BP-AA,SBS-AA(Optional)BP-AA,SBS-AASBS-AA-225.0 concretemin. 1.0-inch ISO 95+GL, Polytherm H, H- Gypsum-FiberRoofBoard Shield,H-Shield CGorENRGY3 NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 45of83 N EMO|etc. TABLE3A:STRUCTURALCONCRETEDECKS;M IN.2,500 PSI–NEWCONSTRUCTION OR REROOF(T EAR-O FF) SYSTEMTYPEA-1:BONDEDINSULATION,BONDEDROOFCOVER R EFER TO N OTE 16 FOR VAPORBARRIEROPTIONS BaseInsulationLayerTopInsulationLayerRoofCover(Note15) Deck System*MDP Primer AttachAttach No. (psf) (Note1) TypeTypeBasePlyPlyCapPly (Notes6,7,8)(Notes6,7,8) Min.1.5-inchUltra-MaxorMulti-MaxFA-3, Structuralmin. 1.3-inch Polytherm G, ACFoam III orMin.0.25-inchSECUROCK C-11NoneCR-20CR-20APP-TA(Optional)APP-TAAPP-TA-232.5 concretemin. 1.0-inch ISO 95+GL, Polytherm H, H-Gypsum-FiberRoofBoard Shield,H-Shield CGorENRGY3 (Optional) Min. 1.5-inch Polytherm, StructuralMin.0.25-inchDensDeckSBS-TA, APP-(Optional) SBS-TA, APP- ACFoam II, Polytherm G, ACFoam III, C-12NoneCR-20CR-20SBS-TA,APP-TA-282.5 concretePrimeTATA PolythermH, H-Shield Min.0.25-inchSECUROCK (Optional) Min. 1.5-inch Polytherm, StructuralGypsum-FiberRoofBoardorSBS-TA, APP-(Optional) SBS-TA, APP- C-13NoneACFoam II, Polytherm G, ACFoam III,CR-20CR-20SBS-TA,APP-TA-322.5 concreteDEXcell FA Glass Mat RoofTATA PolythermH, H-Shield Board OB ClassicOB Classic Structural(Optional)Min.2-inchPolytherm,ACFoamMin.0.25-inchSECUROCK C-14None(full-(full-BP-AA,SBS-AA(Optional)BP-AA,SBS-AASBS-AA-225.0 concreteII,PolythermHorH-ShieldGypsum-FiberRoofBoard coverage)coverage) OB ClassicOB Classic Structural(Optional)Min.2-inchPolytherm,ACFoamMin.0.25-inchSECUROCK C-15None(full-(full-APP-TA(Optional)APP-TAAPP-TA-232.5 concreteII,PolythermHorH-Shield Gypsum-FiberRoofBoard coverage)coverage) Min. 1.5-inch Polytherm, ACFoam II, StructuralPolytherm G, ACFoam III, ENRGY 3,Min.0.25-inchSECUROCK C-16PG100HotasphaltHotasphaltBP-AA,SBS-AA(Optional)BP-AA,SBS-AASBS-AA-225.0 concretePolytherm H, H-Shield, H-Shield CG or Gypsum-FiberRoofBoard Multi-MaxFA3 Min. 1.5-inch Polytherm, ACFoam II, StructuralPolytherm G, ACFoam III, ENRGY 3,Min.0.25-inchSECUROCK C-17PG100HotasphaltHotasphaltAPP-TA(Optional)APP-TAAPP-TA-232.5 concretePolythermH, H-Shield, H-Shield CG or Gypsum-FiberRoofBoard Multi-MaxFA3 (Optional if(Optional if using AA StructuralMin.0.75-inchFescoBoardSBS-AA, SBS-TA, using AA Ply)Base) BP-AA, SBS-AA, C-18PG100HotasphaltNoneN/A-277.5 concrete(homogeneous)APP-TA BP-AA,SBS-AASBS-TAorAPP-TA Min. 1.5-inch Polytherm, ACFoam II, (Optional if(Optional if using AA StructuralPolytherm G, ACFoamIII, ENRGY 3,Min.0.75-inchFescoBoardSBS-AA, SBS-TA, C-19PG100HotasphaltHotasphaltusing AA Ply)Base) BP-AA, SBS-AA,-290.0 concretePolytherm H, H-Shield, H-Shield CG or(homogeneous)APP-TA BP-AA,SBS-AASBS-TAorAPP-TA Multi-MaxFA3 (Optional if(Optional if using AA StructuralMin.0.5-inchStructodekHighDensitySBS-AA, SBS-TA, C-20PG100HotasphaltNoneN/Ausing AA Ply)Base) BP-AA, SBS-AA,-285.0 concreteFiberboard RoofInsulation APP-TA BP-AA,SBS-AASBS-TAorAPP-TA NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 46of83 N EMO|etc. TABLE3A:STRUCTURALCONCRETEDECKS;M IN.2,500 PSI–NEWCONSTRUCTION OR REROOF(T EAR-O FF) SYSTEMTYPEA-1:BONDEDINSULATION,BONDEDROOFCOVER R EFER TO N OTE 16 FOR VAPORBARRIEROPTIONS BaseInsulationLayerTopInsulationLayerRoofCover(Note15) Deck System*MDP Primer AttachAttach No. (psf) (Note1) TypeTypeBasePlyPlyCapPly (Notes6,7,8)(Notes6,7,8) Min. 1.5-inch Polytherm, ACFoam II, Min.0.5-inchStructodek(Optional if(Optional if using AA StructuralPolytherm G, ACFoam III, ENRGY 3,SBS-AA, SBS-TA, C-21PG100HotasphaltHighDensityFiberboardRoofHotasphaltusing AA Ply)-480.0 Base) BP-AA, SBS-AA, concretePolytherm H, H-Shield, H-Shield CG orAPP-TA InsulationBP-AA,SBS-AASBS-TAorAPP-TA Multi-MaxFA3 Min. 1.5-inch Polytherm, ACFoam II, (Optional if(Optional if using AA StructuralPolytherm G, ACFoam III, ENRGY 3,Min.0.25-inchDensDeckSBS-AA, SBS-TA, using AA Ply)Base) BP-AA, SBS-AA, C-22PG100HotasphaltHotasphalt-480.0 concretePolytherm H, H-Shield, H-Shield CG orPrimeAPP-TA BP-AA,SBS-AASBS-TAorAPP-TA Multi-MaxFA3 (Optional if(Optional if using AA StructuralSBS-AA, SBS-TA, C-23PG100Min.0.25-inchDensDeckPrimeHotasphaltNoneN/Ausing AA Ply)Base) BP-AA, SBS-AA,-510.0 concrete APP-TA BP-AA,SBS-AASBS-TAorAPP-TA S ELF-A DHERING B ASE P LYTO I NSULATION: Structural(Optiona(Optional) additional(Optional)SBS-SA,SBS-SBS-SA,APP-SA, C-24Min.1.5-inchH-ShieldorMulti-MaxFA3D-ISD-ISSBS-SA-67.5 concretel)PG100layers(s)ofbaseinsulationTA,APP-TASBS-TA,APP-TA Structural(Optional) additional(Optional) SBS-TA, APP- C-25NoneMin.1.5-inchPolythermH,H-ShieldD-ISD-ISSBS-SASBS-TA,APP-TA-122.5 concretelayers(s)ofbaseinsulationTA Structural(OptionaMin. 1.5-inch Polytherm, ACFoam II or(Optional) additional(Optional)SBS-SA,SBS-SBS-SA,APP-SA, C-26D-ISD-ISSBS-SA-135.0 concretel)PG100ENRGY3layers(s)ofbaseinsulationTA,APP-TASBS-TA,APP-TA Structural(Optional)additionallayers C-27NoneMin.1.5-inch,min.2.0pcfInsulfoamOB500OB500SBS-SA(Optional)SBS-SASBS-SA,APP-SA-120.0 concreteofbaseinsulation Structural(Optional) additional(Optional) SBS-TA, APP- C-28NoneMin.1.5-inchPolytherm,ACFoamIIOB500OB500SBS-SASBS-TA,APP-TA-122.5 concretelayers(s)ofbaseinsulationTA Structural(Optional) additional(Optional)SBS-SA,SBS-SBS-SA,APP-SA, C-29NoneMin.1.5-inchENRGY3OB500OB500SBS-SA-127.5 concretelayers(s)ofbaseinsulationTA,APP-TASBS-TA,APP-TA Structural(Optional) additional(Optional)SBS-SA,SBS-SBS-SA,APP-SA, C-30NoneMin.1.5-inchPolythermHorH-ShieldOB500OB500SBS-SA-150.0 concretelayers(s)ofbaseinsulationTA,APP-TASBS-TA,APP-TA Min. 1.5-inch Polytherm, ACFoam II, StructuralM-OSFA or(Optional) additionalM-OSFA or(Optional) SBS-TA, APP- Polytherm G, ACFoam III, Polytherm H, H- C-31NoneSBS-SASBS-TA,APP-TA-122.5 concreteM-PG1layers(s)ofbaseinsulationM-PG1TA Shield StructuralMin. 1.5-inch Polytherm, ACFoam II,(Optional) additional(Optional)SBS-SA,SBS-SBS-SA,APP-SA, C-32NoneM-OSFAM-OSFASBS-SA-232.5 concreteENRGY3,H-ShieldorMulti-MaxFA3layers(s)ofbaseinsulationTA,APP-TASBS-TA,APP-TA NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 47of83 N EMO|etc. TABLE3A:STRUCTURALCONCRETEDECKS;M IN.2,500 PSI–NEWCONSTRUCTION OR REROOF(T EAR-O FF) SYSTEMTYPEA-1:BONDEDINSULATION,BONDEDROOFCOVER R EFER TO N OTE 16 FOR VAPORBARRIEROPTIONS BaseInsulationLayerTopInsulationLayerRoofCover(Note15) Deck System*MDP Primer AttachAttach No. (psf) (Note1) TypeTypeBasePlyPlyCapPly (Notes6,7,8)(Notes6,7,8) Min. 1-inch Polytherm, ACFoam II, (Optional) additional Polytherm G, ACFoam III, EnergyGuard StructuralM-OSFA orM-OSFA orSBS-CA1, SBS- layers(s)ofbaseinsulation, C-33NonePolyisoInsulation,ENRGY3,PolythermH,SBS-SANone-290.0 concreteM-PG1M-PG1CA2 optionally primed with H-Shield, ISO 95+ GL, Multi-Max FA3, POLYBRITE745orWB3000 RESISTAorUltraMax. StructuralMin.1.5-inchPolytherm,ACFoamII,(Optional) additional(Optional) SBS-TA, APP- C-34NoneCR-20CR-20SBS-SASBS-TA,APP-TA-122.5 concretePolythermH, H-Shieldlayers(s)ofbaseinsulationTA Structural(Optional)additionallayers C-35NoneMin.1.5-inch,min.2.0pcfInsulfoamCR-20CR-20SBS-SA(Optional)SBS-SASBS-SA,APP-SA-240.0 concreteofbase insulation OB ClassicOB Classic StructuralMin. 2-inch Polytherm, ACFoam II,(Optional) additional(Optional)SBS-SA,SBS-SBS-SA,APP-SA, (full-(full- C-36NoneSBS-SA-270.0 concretePolythermHor H-ShieldTA,APP-TASBS-TA,APP-TA layers(s)ofbaseinsulation coverage)coverage) Min. 1.5-inch Polytherm, ACFoam II, StructuralPolytherm G, ACFoam III, ENRGY 3,(Optional) additional(Optional)SBS-SA,SBS-SBS-SA,APP-SA, C-37PG100HotasphaltHotasphaltSBS-SA-480.0 concretePolythermH, H-Shield, H-Shield CG orlayers(s)ofbaseinsulationTA,APP-TASBS-TA,APP-TA Multi-MaxFA3 H YBRID S YSTEMSWITH S ELF-A DHERING APPB ASE P LYTO I NSULATION: Structural(Optiona(Optional) additional C-38Min.1.5-inchH-ShieldorMulti-MaxFA3D-ISD-ISAPP-SA-H(Optional)APP-TAAPP-TA-67.5 concretel)PG100layers(s)ofbaseinsulation Structural(Optional) additional C-39NoneMin.1.5-inchPolythermH,H-ShieldD-ISD-ISAPP-SA-H(Optional)APP-TAAPP-TA-122.5 concretelayers(s)ofbaseinsulation Structural(OptionaMin. 1.5-inch Polytherm, ACFoam II or(Optional) additional C-40D-ISD-ISAPP-SA-H(Optional)APP-TAAPP-TA-135.0 concretel)PG100ENRGY3layers(s)ofbaseinsulation Structural(Optional) additional C-41NoneMin.1.5-inchPolytherm,ACFoamIIOB500OB500APP-SA-H(Optional)APP-TAAPP-TA-122.5 concretelayers(s)ofbaseinsulation Structural(Optional) additional C-42NoneMin.1.5-inchENRGY3OB500OB500APP-SA-H(Optional)APP-TAAPP-TA-127.5 concretelayers(s)ofbaseinsulation Structural(Optional) additional C-43NoneMin.1.5-inchPolythermHorH-ShieldOB500OB500APP-SA-H(Optional)APP-TAAPP-TA-150.0 concretelayers(s)ofbaseinsulation Min. 1.5-inch Polytherm, ACFoam II, StructuralM-OSFA or(Optional) additionalM-OSFA or C-44NonePolytherm G, ACFoam III, Polytherm H, H-APP-SA-H(Optional)APP-TAAPP-TA-122.5 concrete M-PG1layers(s)ofbaseinsulationM-PG1 Shield StructuralMin. 1.5-inch Polytherm, ACFoam II,(Optional) additional C-45NoneM-OSFAM-OSFAAPP-SA-H(Optional)APP-TAAPP-TA-232.5 concreteENRGY3,H-ShieldorMulti-MaxFA3layers(s)ofbaseinsulation NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 48of83 N EMO|etc. TABLE3A:STRUCTURALCONCRETEDECKS;M IN.2,500 PSI–NEWCONSTRUCTION OR REROOF(T EAR-O FF) SYSTEMTYPEA-1:BONDEDINSULATION,BONDEDROOFCOVER R EFER TO N OTE 16 FOR VAPORBARRIEROPTIONS BaseInsulationLayerTopInsulationLayerRoofCover(Note15) Deck System*MDP Primer AttachAttach No. (psf) (Note1) TypeTypeBasePlyPlyCapPly (Notes6,7,8)(Notes6,7,8) StructuralMin. 1.5-inch Polytherm, ACFoam II,(Optional) additional C-46NoneCR-20CR-20APP-SA-H(Optional)APP-TAAPP-TA-122.5 concretePolythermH, H-Shieldlayers(s)ofbaseinsulation OB ClassicOB Classic StructuralMin. 2-inch Polytherm, ACFoam II,(Optional) additional (full-(full- C-47NoneAPP-SA-H(Optional)APP-TAAPP-TA-270.0 concretePolythermHor H-Shield layers(s)ofbaseinsulation coverage)coverage) Min. 1.5-inch Polytherm, ACFoam II, StructuralPolytherm G, ACFoam III, ENRGY 3,(Optional) additional C-48PG100HotasphaltHotasphaltAPP-SA-H(Optional)APP-TAAPP-TA-480.0 concretePolytherm H, H-Shield, H-Shield CG orlayers(s)ofbaseinsulation Multi-MaxFA3 H YBRID S YSTEMSWITH S ELF-A DHERING SBSB ASE P LYTO I NSULATION: Structural(Optiona(Optional) additional C-49Min.1.5-inchH-ShieldorMulti-MaxFA3D-ISD-ISSBS-SA-H(Optional)SBS-TASBS-TA-67.5 concretel)PG100layers(s)ofbaseinsulation Structural(Optional) additional C-50NoneMin.1.5-inchPolythermH,H-ShieldD-ISD-ISSBS-SA-H(Optional)SBS-TASBS-TA-122.5 concretelayers(s)ofbaseinsulation Structural(OptionaMin. 1.5-inch Polytherm, ACFoam II or(Optional) additional C-51D-ISD-ISSBS-SA-H(Optional)SBS-TASBS-TA-135.0 concretel)PG100ENRGY3layers(s)ofbaseinsulation Structural(Optional) additional C-52NoneMin.1.5-inchPolytherm,ACFoamIIOB500OB500SBS-SA-H(Optional)SBS-TASBS-TA-122.5 concretelayers(s)ofbaseinsulation Structural(Optional) additional C-53NoneMin.1.5-inchENRGY3OB500OB500SBS-SA-H(Optional)SBS-TASBS-TA-127.5 concretelayers(s)ofbaseinsulation Structural(Optional) additional C-54NoneMin.1.5-inchPolythermHorH-ShieldOB500OB500SBS-SA-H(Optional)SBS-TASBS-TA-150.0 concretelayers(s)ofbaseinsulation Min. 1.5-inch Polytherm, ACFoam II, StructuralM-OSFA or(Optional) additionalM-OSFA or Polytherm G, ACFoam III, Polytherm H, H- C-55NoneSBS-SA-H(Optional)SBS-TASBS-TA-122.5 concreteM-PG1layers(s)ofbaseinsulationM-PG1 Shield StructuralMin. 1.5-inch Polytherm, ACFoam II,(Optional) additional C-56NoneM-OSFAM-OSFASBS-SA-H(Optional)SBS-TASBS-TA-232.5 concreteENRGY3,H-ShieldorMulti-MaxFA3layers(s)ofbaseinsulation StructuralMin.1.5-inchPolytherm,ACFoamII,(Optional) additional C-57NoneCR-20CR-20SBS-SA-H(Optional)SBS-TASBS-TA-122.5 concretePolythermH,H-Shieldlayers(s)ofbaseinsulation OB ClassicOB Classic StructuralMin. 2-inch Polytherm, ACFoam II,(Optional) additional (full-(full- C-58NoneSBS-SA-H(Optional)SBS-TASBS-TA-270.0 concretePolythermHor H-Shield layers(s)ofbaseinsulation coverage)coverage) NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 49of83 N EMO|etc. TABLE3A:STRUCTURALCONCRETEDECKS;M IN.2,500 PSI–NEWCONSTRUCTION OR REROOF(T EAR-O FF) SYSTEMTYPEA-1:BONDEDINSULATION,BONDEDROOFCOVER R EFER TO N OTE 16 FOR VAPORBARRIEROPTIONS BaseInsulationLayerTopInsulationLayerRoofCover(Note15) Deck System*MDP Primer AttachAttach No. (psf) (Note1) TypeTypeBasePlyPlyCapPly (Notes6,7,8)(Notes6,7,8) Min. 1.5-inch Polytherm, ACFoam II, StructuralPolytherm G, ACFoamIII, ENRGY 3,(Optional) additional C-59PG100HotasphaltHotasphaltSBS-SA-H(Optional)SBS-TASBS-TA-480.0 concretePolytherm H, H-Shield, H-Shield CG orlayers(s)ofbaseinsulation Multi-MaxFA3 S ELF-A DHERING B ASE P LYTO C OVERBOARD: Min. 0.25-inch Dens Deck Structural(Optional)SBS-SA,SBS-SBS-SA,APP-SA, C-60NoneMin.1.5-inchMulti-MaxFA3D-ISPrime or SECUROCK Gypsum-D-ISSBS-SA-67.5 concreteTA,APP-TASBS-TA,APP-TA FiberRoofBoard Min. 1.5-inch, min. 2.0 pcf Insulfoam, StructuralMin.0.25-inchDensDeck Polytherm, ACFoam II, ENRGY 3, Polytherm C-61NoneD-ISD-ISSBS-SA(Optional)SBS-SASBS-SA,APP-SA-72.5 concretePrime HorH-Shield StructuralMin.0.25-inchDensDeck,(Optional) SBS-TA, APP- C-62NoneMin.1.5-inch,min.2.0pcfInsulfoamD-ISD-ISSBS-SASBS-TA,APP-TA-120.0 concreteDensDeckPrimeTA (Optional) Min. 1.5-inch Polytherm,Min. 0.25-inch Dens Deck Structural(Optional) SBS-TA, APP- ACFoam II, Polytherm G, ACFoam III,Primeoptionallyprimedwith C-63NoneD-ISD-ISSBS-SASBS-TA,APP-TA-282.5 concreteTA PolythermH, H-ShieldPOLYBRITE745orWB3000 (Optional) Min. 1.5-inch Polytherm, StructuralMin.0.25-inchDEXcellFA(Optional) SBS-TA, APP- C-64NoneACFoam II, Polytherm G, ACFoam III,D-ISD-ISSBS-SASBS-TA,APP-TA-322.5 concreteGlassMatRoof BoardTA PolythermH, H-Shield Min.0.25-inchSECUROCK (Optional) Min. 1.5-inch Polytherm, Structural(Optional)SBS-SA,SBS-SBS-SA,APP-SA, Gypsum-Fiber Roof Board C-65NoneACFoam II, Polytherm G, ACFoam III,D-ISD-ISSBS-SA-322.5 concreteTA,APP-TASBS-TA,APP-TA optionally primed with PolythermH, H-Shield POLYBRITE745orWB3000 StructuralMin.1.5-inchPolytherm,ACFoamII,Min.0.25-inchDensDeck C-66NoneOB500OB500SBS-SA(Optional)SBS-SASBS-SA,APP-SA-72.5 concreteENRGY3,H-Shield orISO95+GLPrime StructuralMin.0.25-inchDensDeck,(Optional) SBS-TA, APP- C-67NoneMin.1.5-inchENRGY3OB500OB500SBS-SASBS-TA,APP-TA-127.5 concreteDensDeckPrimeTA StructuralMin. 1.5-inch Polytherm, ACFoam II, H-Min.0.25-inchDensDeck,(Optional) SBS-TA, APP- C-68NoneOB500OB500SBS-SASBS-TA,APP-TA-150.0 concreteShieldorISO95+GLDensDeckPrimeTA (Optional) Min. 1.5-inch Polytherm, StructuralMin.0.25-inchDensDeck(Optional) SBS-TA, APP- C-69NoneACFoam II, Polytherm G, ACFoam III,OB500OB500SBS-SASBS-TA,APP-TA-282.5 concretePrimeTA PolythermH, H-Shield NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 50of83 N EMO|etc. TABLE3A:STRUCTURALCONCRETEDECKS;M IN.2,500 PSI–NEWCONSTRUCTION OR REROOF(T EAR-O FF) SYSTEMTYPEA-1:BONDEDINSULATION,BONDEDROOFCOVER R EFER TO N OTE 16 FOR VAPORBARRIEROPTIONS BaseInsulationLayerTopInsulationLayerRoofCover(Note15) Deck System*MDP Primer AttachAttach No. (psf) (Note1) TypeTypeBasePlyPlyCapPly (Notes6,7,8)(Notes6,7,8) (Optional) Min. 1.5-inch Polytherm, StructuralMin.0.25-inchDEXcellFA(Optional) SBS-TA, APP- C-70NoneACFoam II, Polytherm G, ACFoamIII,OB500OB500SBS-SASBS-TA,APP-TA-322.5 concreteGlassMatRoof BoardTA PolythermH, H-Shield Min.0.25-inchSECUROCK (Optional) Min. 1.5-inch Polytherm, StructuralGypsum-Fiber Roof Board(Optional)SBS-SA,SBS-SBS-SA,APP-SA, C-71NoneACFoam II, Polytherm G, ACFoamIII,OB500OB500SBS-SA-322.5 concreteoptionally primed withTA,APP-TASBS-TA,APP-TA PolythermH, H-Shield POLYBRITE745orWB3000 StructuralMin. 1.5-inch Polytherm, ACFoam II,Min.0.25-inchDensDeck C-72NoneM-OSFAM-OSFASBS-SA(Optional)SBS-SASBS-SA,APP-SA-72.5 concreteENRGY3,H-ShieldorMulti-MaxFA3Prime StructuralMin. 1.5-inch Polytherm, ACFoam II,Min.0.25-inchSECUROCK(Optional)SBS-SA,SBS-SBS-SA,APP-SA, C-73NoneM-OSFA-232.5 M-OSFASBS-SA concreteENRGY3,H-ShieldorMulti-MaxFA3Gypsum-FiberRoofBoardTA,APP-TASBS-TA,APP-TA (Optional) Min. 1.5-inch Polytherm, StructuralM-OSFA orMin.0.25-inchDensDeckM-OSFA or(Optional) SBS-TA, APP- C-74NoneACFoam II, Polytherm G, ACFoam III,SBS-SASBS-TA,APP-TA-282.5 concreteTA M-PG1PrimeM-PG1 PolythermH, H-Shield (Optional) Min. 1.5-inch Polytherm, StructuralM-OSFA orMin.0.25-inchDEXcellFAM-OSFA or(Optional) SBS-TA, APP- C-75NoneACFoam II, Polytherm G, ACFoam III,SBS-SASBS-TA,APP-TA-322.5 concreteM-PG1GlassMatRoof BoardM-PG1TA PolythermH, H-Shield Min.0.25-inchSECUROCK (Optional) Min. 1.5-inch Polytherm, StructuralM-OSFA orGypsum-Fiber Roof BoardM-OSFA or(Optional)SBS-SA,SBS-SBS-SA,APP-SA, C-76NoneACFoamII, Polytherm G, ACFoam III,SBS-SA-322.5 concreteM-PG1optionally primed withM-PG1TA,APP-TASBS-TA,APP-TA PolythermH, H-Shield POLYBRITE745orWB3000 Min. 1.5-inch, min. 2.0 pcf Insulfoam, Min. 2-inchPolytherm,ACFoamII,min.1.5-inch StructuralUltra-Max or Multi-Max FA-3, min. 1.3-inchMin.0.25-inchDensDeck, C-77NoneCR-20CR-20SBS-SA(Optional)SBS-SASBS-SA,APP-SA-72.5 concretePolytherm G, ACFoam III or min. 1.0-inchDensDeckPrime ISO 95+GL, PolythermH, H-Shield, H-Shield CGorENRGY3 Min. 1.5-inch, min. 2.0 pcf Insulfoam, Min. 1.5-inchUltra-MaxorMulti-MaxFA-3,min. StructuralMin.0.25-inchDensDeck,(Optional) SBS-TA, APP- C-78None1.3-inch Polytherm G, ACFoam III or min.CR-20CR-20SBS-SASBS-TA,APP-TA-240.0 concreteDensDeckPrimeTA 1.0-inch ISO 95+GL, Polytherm H, H-Shield, H-ShieldCGorENRGY3 NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 51of83 N EMO|etc. TABLE3A:STRUCTURALCONCRETEDECKS;M IN.2,500 PSI–NEWCONSTRUCTION OR REROOF(T EAR-O FF) SYSTEMTYPEA-1:BONDEDINSULATION,BONDEDROOFCOVER R EFER TO N OTE 16 FOR VAPORBARRIEROPTIONS BaseInsulationLayerTopInsulationLayerRoofCover(Note15) Deck System*MDP Primer AttachAttach No. (psf) (Note1) TypeTypeBasePlyPlyCapPly (Notes6,7,8)(Notes6,7,8) Min.1.5-inchUltra-MaxorMulti-MaxFA-3, Structuralmin. 1.3-inch Polytherm G, ACFoam III orMin.0.25-inchSECUROCK(Optional)SBS-SA,SBS-SBS-SA,APP-SA, C-79NoneCR-20CR-20SBS-SA-240.0 concretemin. 1.0-inch ISO 95+GL, Polytherm H, H-Gypsum-FiberRoofBoardTA,APP-TASBS-TA,APP-TA Shield,H-Shield CGorENRGY3 (Optional) Min. 1.5-inch Polytherm, StructuralMin.0.25-inchDensDeck(Optional) SBS-TA, APP- ACFoam II, Polytherm G, ACFoam III, C-80NoneCR-20CR-20SBS-SASBS-TA,APP-TA-282.5 concretePrimeTA PolythermH, H-Shield (Optional) Min. 1.5-inch Polytherm, StructuralMin.0.25-inchorDEXcellFA(Optional) SBS-TA, APP- ACFoam II, Polytherm G, ACFoam III, C-81NoneCR-20CR-20SBS-SASBS-TA,APP-TA-322.5 concreteGlassMat RoofBoardTA PolythermH, H-Shield Min.0.25-inchSECUROCK (Optional) Min. 1.5-inch Polytherm, StructuralGypsum-Fiber Roof Board(Optional)SBS-SA,SBS-SBS-SA,APP-SA, ACFoam II, Polytherm G, ACFoam III, C-82NoneCR-20CR-20SBS-SA-322.5 concreteoptionally primed withTA,APP-TASBS-TA,APP-TA PolythermH, H-Shield POLYBRITE745orWB3000 OB ClassicOB Classic StructuralMin. 2-inch Polytherm, ACFoam II,Min.0.25-inchSECUROCK(Optional)SBS-SA,SBS-SBS-SA,APP-SA, C-83None(full-(full-SBS-SA-350.0 concretePolythermHor H-ShieldTA,APP-TASBS-TA,APP-TA Gypsum-FiberRoofBoard coverage)coverage) Min. 1.5-inch Polytherm, ACFoam II, StructuralPolytherm G, ACFoam III, ENRGY 3,Min.0.25-inchSECUROCK(Optional)SBS-SA,SBS-SBS-SA,APP-SA, C-84PG100HotasphaltHotasphaltSBS-SA-350.0 concretePolythermH, H-Shield, H-Shield CG orTA,APP-TASBS-TA,APP-TA Gypsum-FiberRoofBoard Multi-MaxFA3 H YBRID S YSTEMSWITH S ELF-A DHERING APPB ASE P LYTO C OVERBOARD: StructuralMin.0.25-inchSECUROCK C-85NoneMin.1.5-inchMulti-MaxFA3D-ISD-ISAPP-SA-H(Optional)APP-TAAPP-TA-67.5 concrete Gypsum-FiberRoofBoard StructuralMin.0.25-inchDensDeck, C-86NoneMin.1.5-inch,min.2.0pcfInsulfoamD-ISD-ISAPP-SA-H(Optional)APP-TAAPP-TA-120.0 concreteDensDeckPrime Min.0.25-inchSECUROCK (Optional) Min. 1.5-inch Polytherm, Gypsum-Fiber Roof Board Structural optionally primed with C-87NoneACFoam II, Polytherm G, ACFoam III,D-ISD-ISAPP-SA-H(Optional)APP-TAAPP-TA-322.5 concrete POLYBRITE745orWB3000or PolythermH, H-Shield DEXcellFAGlassMatRoofBoard StructuralMin.0.25-inchDensDeck, C-88NoneMin.1.5-inchENRGY3OB500OB500APP-SA-H(Optional)APP-TAAPP-TA-127.5 concreteDensDeckPrime StructuralMin. 1.5-inch Polytherm, ACFoam II, H-Min.0.25-inchDensDeck, C-89NoneOB500OB500APP-SA-H(Optional)APP-TAAPP-TA-150.0 concreteShieldorISO95+GLDensDeckPrime NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 52of83 N EMO|etc. TABLE3A:STRUCTURALCONCRETEDECKS;M IN.2,500 PSI–NEWCONSTRUCTION OR REROOF(T EAR-O FF) SYSTEMTYPEA-1:BONDEDINSULATION,BONDEDROOFCOVER R EFER TO N OTE 16 FOR VAPORBARRIEROPTIONS BaseInsulationLayerTopInsulationLayerRoofCover(Note15) Deck System*MDP Primer AttachAttach No. (psf) (Note1) TypeTypeBasePlyPlyCapPly (Notes6,7,8)(Notes6,7,8) Min.0.25-inchSECUROCK (Optional) Min. 1.5-inch Polytherm, StructuralGypsum-FiberRoofBoardor C-90NoneACFoam II, Polytherm G, ACFoamIII,OB500OB500APP-SA-H(Optional)APP-TAAPP-TA-322.5 concreteDEXcell FA Glass Mat Roof PolythermH, H-Shield Board Min.0.25-inchSECUROCK (Optional) Min. 1.5-inch Polytherm, StructuralM-OSFA orGypsum-FiberRoofBoardorM-OSFA or ACFoam II, Polytherm G, ACFoam III, C-91NoneAPP-SA-H(Optional)APP-TAAPP-TA-322.5 concreteM-PG1DEXcell FA Glass Mat RoofM-PG1 PolythermH, H-Shield Board Min. 1.5-inch, min. 2.0 pcf Insulfoam, Min. 1.5-inchUltra-MaxorMulti-MaxFA-3,min. StructuralMin.0.25-inchDensDeck, C-92None1.3-inch Polytherm G, ACFoam III or min.CR-20CR-20APP-SA-H(Optional)APP-TAAPP-TA-240.0 concreteDensDeckPrime 1.0-inch ISO 95+GL, Polytherm H, H-Shield, H-ShieldCGorENRGY3 Min.1.5-inchUltra-MaxorMulti-MaxFA-3, Structuralmin. 1.3-inch Polytherm G, ACFoam III orMin.0.25-inchSECUROCK C-93NoneCR-20CR-20APP-SA-H(Optional)APP-TAAPP-TA-240.0 concretemin. 1.0-inch ISO 95+GL, Polytherm H, H-Gypsum-FiberRoofBoard Shield,H-Shield CGorENRGY3 Min.0.25-inchSECUROCK (Optional) Min. 1.5-inch Polytherm, StructuralGypsum-FiberRoofBoardor ACFoam II, Polytherm G, ACFoam III, C-94NoneCR-20CR-20APP-SA-H(Optional)APP-TAAPP-TA-322.5 concreteDEXcell FA Glass Mat Roof PolythermH, H-Shield Board OB ClassicOB Classic StructuralMin. 2-inch Polytherm, ACFoam II,Min.0.25-inchSECUROCK C-95None(full-(full-APP-SA-H(Optional)APP-TAAPP-TA-350.0 concretePolythermHor H-Shield Gypsum-FiberRoofBoard coverage)coverage) Min. 1.5-inch Polytherm, ACFoam II, StructuralPolytherm G, ACFoam III, ENRGY 3,Min.0.25-inchSECUROCK C-96PG100HotasphaltHotasphaltAPP-SA-H(Optional)APP-TAAPP-TA-350.0 concretePolythermH, H-Shield, H-Shield CG or Gypsum-FiberRoofBoard Multi-MaxFA3 H YBRID S YSTEMSWITH S ELF-A DHERING SBSB ASE P LYTO C OVERBOARD: Min. 0.25-inch Dens Deck Structural Prime or SECUROCK Gypsum- C-97NoneMin.1.5-inchMulti-MaxFA3D-ISD-ISSBS-SA-H(Optional)SBS-TASBS-TA-67.5 concrete FiberRoofBoard StructuralMin.0.25-inchDensDeck, C-98NoneMin.1.5-inch,min.2.0pcfInsulfoamD-ISD-ISSBS-SA-H(Optional)SBS-TASBS-TA-120.0 concreteDensDeckPrime NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 53of83 N EMO|etc. TABLE3A:STRUCTURALCONCRETEDECKS;M IN.2,500 PSI–NEWCONSTRUCTION OR REROOF(T EAR-O FF) SYSTEMTYPEA-1:BONDEDINSULATION,BONDEDROOFCOVER R EFER TO N OTE 16 FOR VAPORBARRIEROPTIONS BaseInsulationLayerTopInsulationLayerRoofCover(Note15) Deck System*MDP Primer AttachAttach No. (psf) (Note1) TypeTypeBasePlyPlyCapPly (Notes6,7,8)(Notes6,7,8) StructuralMin. 2-inch Polytherm, ACFoam II, ENRGY-Min.0.25-inchSECUROCK C-99NoneD-IS D-ISSBS-SA-H(Optional)SBS-TASBS-TA-247.5 concrete3,PolythermH orH-ShieldGypsum-FiberRoofBoard (Optional) Min. 1.5-inch Polytherm,Min. 0.25-inch Dens Deck Structural ACFoam II, Polytherm G, ACFoam III,Primeoptionallyprimedwith C-100NoneD-ISD-ISSBS-SA-H(Optional)SBS-TASBS-TA-282.5 concrete PolythermH, H-ShieldPOLYBRITE745orWB3000 Min.0.25-inchSECUROCK (Optional) Min. 1.5-inch Polytherm, Gypsum-Fiber Roof Board Structural optionally primed with C-101NoneACFoam II, Polytherm G, ACFoam III,D-ISD-ISSBS-SA-H(Optional)SBS-TASBS-TA-322.5 concrete POLYBRITE745orWB3000or PolythermH, H-Shield DEXcellFAGlassMatRoofBoard StructuralMin.0.25-inchDensDeck, C-102NoneMin.1.5-inchENRGY3OB500OB500SBS-SA-H(Optional)SBS-TASBS-TA-127.5 concreteDensDeckPrime StructuralMin. 1.5-inch Polytherm, ACFoam II, H-Min.0.25-inchDensDeck, C-103NoneOB500OB500SBS-SA-H(Optional)SBS-TASBS-TA-150.0 concreteShieldorISO95+GLDensDeckPrime StructuralMin. 2-inch Polytherm, ACFoam II, ENRGY-Min.0.25-inchSECUROCK C-104NoneOB500OB500SBS-SA-H(Optional)SBS-TASBS-TA-247.5 concrete3,PolythermH orH-ShieldGypsum-FiberRoofBoard (Optional) Min. 1.5-inch Polytherm, StructuralMin.0.25-inchDensDeck ACFoam II, Polytherm G, ACFoam III, C-105NoneOB500OB500SBS-SA-H(Optional)SBS-TASBS-TA-282.5 concretePrime PolythermH, H-Shield Min.0.25-inchSECUROCK (Optional) Min. 1.5-inch Polytherm, StructuralGypsum-FiberRoofBoardor ACFoam II, Polytherm G, ACFoam III, C-106NoneOB500OB500SBS-SA-H(Optional)SBS-TASBS-TA-322.5 concreteDEXcell FA Glass Mat Roof PolythermH, H-Shield Board StructuralMin. 1.5-inch Polytherm, ACFoam II,Min.0.25-inchSECUROCK C-107NoneM-OSFA M-OSFASBS-SA-H(Optional)SBS-TASBS-TA-232.5 concreteENRGY3,H-ShieldorMulti-MaxFA3Gypsum-FiberRoofBoard StructuralMin. 2-inch Polytherm, ACFoam II, ENRGY-Min.0.25-inchSECUROCK C-108NoneM-OSFAM-OSFASBS-SA-H(Optional)SBS-TASBS-TA-247.5 concrete3,PolythermH orH-ShieldGypsum-FiberRoofBoard (Optional) Min. 1.5-inch Polytherm, StructuralM-OSFA orMin.0.25-inchDensDeckM-OSFA or ACFoam II, Polytherm G, ACFoam III, C-109NoneSBS-SA-H(Optional)SBS-TASBS-TA-282.5 concreteM-PG1PrimeM-PG1 PolythermH, H-Shield Min.0.25-inchSECUROCK (Optional) Min. 1.5-inch Polytherm, StructuralM-OSFA orGypsum-FiberRoofBoardorM-OSFA or ACFoam II, Polytherm G, ACFoam III, C-110NoneSBS-SA-H(Optional)SBS-TASBS-TA-322.5 concreteM-PG1DEXcellFA Glass Mat RoofM-PG1 PolythermH, H-Shield Board NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 54of83 N EMO|etc. TABLE3A:STRUCTURALCONCRETEDECKS;M IN.2,500 PSI–NEWCONSTRUCTION OR REROOF(T EAR-O FF) SYSTEMTYPEA-1:BONDEDINSULATION,BONDEDROOFCOVER R EFER TO N OTE 16 FOR VAPORBARRIEROPTIONS BaseInsulationLayerTopInsulationLayerRoofCover(Note15) Deck System*MDP Primer AttachAttach No. (psf) (Note1) TypeTypeBasePlyPlyCapPly (Notes6,7,8)(Notes6,7,8) Min. 1.5-inch, min. 2.0 pcf Insulfoam, Min. 1.5-inchUltra-MaxorMulti-MaxFA-3,min. StructuralMin.0.25-inchDensDeck, C-111None1.3-inch Polytherm G, ACFoam III or min.CR-20CR-20SBS-SA-H(Optional)SBS-TASBS-TA-240.0 concreteDensDeckPrime 1.0-inch ISO 95+GL, Polytherm H, H-Shield, H-ShieldCGorENRGY3 Min.1.5-inchUltra-MaxorMulti-MaxFA-3, Structuralmin. 1.3-inch Polytherm G, ACFoam III orMin.0.25-inchSECUROCK C-112NoneCR-20CR-20SBS-SA-H(Optional)SBS-TASBS-TA-240.0 concretemin. 1.0-inch ISO 95+GL, Polytherm H, H-Gypsum-FiberRoofBoard Shield,H-Shield CGorENRGY3 StructuralMin. 2-inch Polytherm, ACFoam II, ENRGY-Min.0.25-inchSECUROCK C-113NoneCR-20CR-20SBS-SA-H(Optional)SBS-TASBS-TA-247.5 concrete3,PolythermH orH-ShieldGypsum-FiberRoofBoard (Optional) Min. 1.5-inch Polytherm, StructuralMin.0.25-inchDensDeck C-114NoneACFoam II, Polytherm G, ACFoam III,CR-20CR-20SBS-SA-H(Optional)SBS-TASBS-TA-282.5 concretePrime PolythermH, H-Shield Min.0.25-inchSECUROCK (Optional) Min. 1.5-inch Polytherm, StructuralGypsum-FiberRoofBoardor ACFoam II, Polytherm G, ACFoam III, C-115NoneCR-20CR-20SBS-SA-H(Optional)SBS-TASBS-TA-322.5 concreteDEXcell FA Glass Mat Roof PolythermH, H-Shield Board OB ClassicOB Classic StructuralMin. 2-inch Polytherm, ACFoam II,Min.0.25-inchSECUROCK (full-(full- C-116NoneSBS-SA-H(Optional)SBS-TASBS-TA-350.0 concretePolythermHor H-ShieldGypsum-FiberRoofBoard coverage)coverage) Min. 1.5-inch Polytherm, ACFoam II, StructuralPolytherm G, ACFoam III, ENRGY 3,Min.0.25-inchSECUROCK C-117PG100HotasphaltHotasphaltSBS-SA-H(Optional)SBS-TASBS-TA-350.0 concretePolytherm H, H-Shield, H-Shield CG or Gypsum-FiberRoofBoard Multi-MaxFA3 C OLD-A PPLIED B ASE P LY: Min. 0.25-inch Dens Deck Min. 1-inch Polytherm, ACFoam II, StructuralPrime,DEXcellFAGlassMatSBS-CA1, SBS-(Optional)SBS-CA1,SBS-SBS-CA1, SBS- C-118NonePolytherm G, ACFoam III, ENRGY 3,D-ISD-IS-120.0 concreteRoof Board or SECUROCKCA2CA2CA2,APP-CA1 PolythermHor H-Shield Gypsum-FiberRoofBoard Min. 1-inch Polytherm, ACFoam II,Min. 0.25-inch Dens Deck StructuralSBS-CA1, SBS- Polytherm G, ACFoam III, Polytherm H orPrime or DEXcell FA Glass C-119NoneD-ISD-ISSBS-CA1None-127.5 concreteCA2,APP-CA1 H-ShieldMatRoof Board NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 55of83 N EMO|etc. TABLE3A:STRUCTURALCONCRETEDECKS;M IN.2,500 PSI–NEWCONSTRUCTION OR REROOF(T EAR-O FF) SYSTEMTYPEA-1:BONDEDINSULATION,BONDEDROOFCOVER R EFER TO N OTE 16 FOR VAPORBARRIEROPTIONS BaseInsulationLayerTopInsulationLayerRoofCover(Note15) Deck System*MDP Primer AttachAttach No. (psf) (Note1) TypeTypeBasePlyPlyCapPly (Notes6,7,8)(Notes6,7,8) Min. 1-inch Polytherm, ACFoam II, StructuralMin.0.25-inchSECUROCKSBS-CA1, SBS-SBS-CA1, SBS- C-120NonePolytherm G, ACFoam III, Polytherm H orD-ISD-ISNone-127.5 concreteGypsum-FiberRoofBoardCA2CA2,APP-CA1 H-Shield Min. 0.25-inch Dens Deck StructuralMin. 1-inch ENRGY 3, Polytherm H or H-SBS-CA1, SBS-SBS-CA1, SBS- Prime or SECUROCK Gypsum- C-121NoneD-ISD-ISNone-232.5 concreteShieldCA2CA2 FiberRoofBoard Min. 0.25-inch Dens Deck, Dens Min. 1-inch Polytherm, ACFoam II, Deck Prime, DEXcell FA Glass Mat Polytherm G, ACFoam III, EnergyGuard Roof Board, SECUROCK Gypsum- PolyisoInsulation,ENRGY3,PolythermH, StructuralM-OSFA, M-M-OSFA orSBS-CA1, SBS-(Optional)SBS-CA1,SBS-SBS-CA1, SBS- Fiber Roof Board or SECUROCK C-122None-120.0 Glass-Mat Roof Board, min. 7/16- H-Shield ISO 95+ GL, Multi-Max FA3, concretePG1M-PG1CA2CA2CA2,APP-CA1 inch DEXcell Cement Roof Board RESISTA or UltraMax or min. 2-inch or min. 0.5-inch SECUROCK DECKMATEPlusorDECKMATEPlusFA CementRoofBoard Min. 0.25-inch Dens Deck Min. 1-inch Polytherm or ACFoam II, Prime or DEXcell FA Glass Polytherm G, ACFoam III, EnergyGuard MatRoofBoard,min.7/16- StructuralPolyisoInsulation,ENRGY3,PolythermH,M-OSFA, M-M-OSFA, M-SBS-CA1, SBS- C-123NoneSBS-CA1None-127.5 inch DEXcell Cement Roof H-Shield, ISO 95+ GL, Multi-Max FA3, concretePG1PG1CA2,APP-CA1 Board or min. 0.5-inch RESISTA or UltraMax or min. 2-inch SECUROCK Cement Roof DECKMATEPlusorDECKMATEPlusFA Board Min. 1-inch Polytherm or ACFoam II, Polytherm G, ACFoam III, EnergyGuard StructuralPolyisoInsulation,ENRGY3,PolythermH,M-OSFA, M-Min.0.25-inchSECUROCKM-OSFA, M-SBS-CA1, SBS-SBS-CA1, SBS- C-124NoneNone-127.5 concreteH-Shield, ISO 95+ GL, Multi-Max FA3,PG1Gypsum-FiberRoofBoardPG1CA2CA2,APP-CA1 RESISTA or UltraMax or min. 2-inch DECKMATEPlusorDECKMATEPlusFA Min. 0.25-inch Dens Deck, Dens Min. 1-inch Polytherm or ACFoam II, Deck Prime, DEXcell FA Glass Mat Polytherm G, ACFoam III, EnergyGuard Roof Board, SECUROCK Gypsum- StructuralPolyisoInsulation,ENRGY3,PolythermH,M-OSFA, M-M-OSFA, M-SBS-CA1, SBS-SBS-CA1, SBS- Fiber Roof Board or SECUROCK C-125NoneNone-232.5 Glass-Mat Roof Board, min. 7/16- H-Shield, ISO 95+ GL, Multi-Max FA3, concretePG1PG1CA2CA2 inch DEXcell Cement Roof Board RESISTA or UltraMax or min. 2-inch or min. 0.5-inch SECUROCK DECKMATEPlusorDECKMATEPlusFA CementRoofBoard NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 56of83 N EMO|etc. TABLE3A:STRUCTURALCONCRETEDECKS;M IN.2,500 PSI–NEWCONSTRUCTION OR REROOF(T EAR-O FF) SYSTEMTYPEA-1:BONDEDINSULATION,BONDEDROOFCOVER R EFER TO N OTE 16 FOR VAPORBARRIEROPTIONS BaseInsulationLayerTopInsulationLayerRoofCover(Note15) Deck System*MDP Primer AttachAttach No. (psf) (Note1) TypeTypeBasePlyPlyCapPly (Notes6,7,8)(Notes6,7,8) Min. 0.25-inch Dens Deck Min. 1-inch Polytherm, ACFoam II, StructuralPrime,DEXcellFAGlassMatSBS-CA1, SBS-(Optional)SBS-CA1,SBS-SBS-CA1, SBS- C-126NonePolytherm G, ACFoam III, ENRGY 3,OB500OB500-120.0 concreteRoof Board or SECUROCKCA2CA2CA2,APP-CA1 PolythermH,H-ShieldorMulti-MaxFA3 Gypsum-FiberRoofBoard Min. 1-inch Polytherm, ACFoam II,Min. 0.25-inch Dens Deck StructuralSBS-CA1, SBS- Polytherm G, ACFoam III, ENRGY 3,Prime or DEXcell FA Glass C-127NoneOB500OB500SBS-CA1None-127.5 concreteCA2,APP-CA1 PolythermH,H-ShieldorMulti-MaxFA3MatRoof Board Min. 1-inch Polytherm, ACFoam II, StructuralMin.0.25-inchSECUROCKSBS-CA1, SBS-SBS-CA1, SBS- Polytherm G, ACFoam III, ENRGY 3, C-128NoneOB500OB500None-127.5 concreteGypsum-FiberRoofBoardCA2CA2,APP-CA1 PolythermH,H-ShieldorMulti-MaxFA3 Min. 0.25-inch Dens Deck StructuralMin.1-inchPolytherm,ACFoamII,ENRGYPrime,DEXcellFAGlassMatSBS-CA1, SBS-SBS-CA1, SBS- C-129NoneOB500OB500None-232.5 concrete3orMulti-Max FA3Roof Board or SECUROCKCA2CA2 Gypsum-FiberRoofBoard Min. 1-inch Polytherm, ACFoam II,Min. 0.25-inch Dens Deck StructuralSBS-CA1, SBS-(Optional)SBS-CA1,SBS-SBS-CA1, SBS- C-130NonePolytherm G, ACFoam III, ENRGY 3,CR-20Prime or SECUROCK Gypsum-CR-20-120.0 concreteCA2CA2CA2,APP-CA1 PolythermH,H-ShieldorMulti-MaxFA3FiberRoofBoard Min. 1-inch Polytherm, ACFoam II,Min. 0.25-inch Dens Deck StructuralSBS-CA1, SBS- Polytherm G, ACFoam III, ENRGY 3,Prime or DEXcell FA Glass C-131NoneCR-20CR-20SBS-CA1None-127.5 concreteCA2,APP-CA1 PolythermH,H-ShieldorMulti-MaxFA3MatRoof Board Min. 1-inch Polytherm, ACFoam II, StructuralMin.0.25-inchSECUROCKSBS-CA1, SBS-SBS-CA1, SBS- Polytherm G, ACFoam III, ENRGY 3, C-132NoneCR-20CR-20None-127.5 concreteGypsum-FiberRoofBoardCA2CA2,APP-CA1 PolythermH,H-ShieldorMulti-MaxFA3 Min. 0.25-inch Dens Deck StructuralMin. 1-inch ENRGY 3, Polytherm H, H-SBS-CA1, SBS-SBS-CA1, SBS- Prime or SECUROCK Gypsum- C-133NoneCR-20CR-20None-232.5 concreteShield,Multi-MaxFA3CA2CA2 FiberRoofBoard NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 57of83 N EMO|etc. TABLE3B:STRUCTURALCONCRETEDECKS–NEWCONSTRUCTION OR REROOF(T EAR-O FF) SYSTEMTYPEF:NON-INSULATED,BONDEDBASESHEET,BONDEDROOFCOVER RoofCover(Note15) Deck System*MDP Primer No. (psf) (Note1) BasePlyPlyCapPly A SPHALT-OR T ORCH-A PPLIED B ASE P LY: C-134StructuralconcretePG100(Optional)SBS-TA(Optional)SBS-TASBS-TA-495.0 (Optional if using asphalt applied Base) BP-AA, C-135StructuralconcretePG100BP-AA(OptionalifusingasphaltappliedPly)SBS-AA,SBS-TA,APP-TA-622.5 SBS-AA,SBS-TAorAPP-TA S ELF-A DHERING B ASE P LY: C-136StructuralconcretePG100SBS-SA(Optional)SBS-SA,SBS-TA,APP-TASBS-SA,APP-SA,SBS-TA,APP-TA-315.0 H YBRID S YSTEMSWITH S ELF-A DHERING APPB ASE P LY: C-137StructuralconcretePG100APP-SA-H(Optional)APP-TAAPP-TA-315.0 H YBRID S YSTEMSWITH S ELF-A DHERING SBSB ASE P LY: C-138StructuralconcretePG100SBS-SA-H(Optional)SBS-TASBS-TA-315.0 C OLD-A PPLIED B ASE P LY: C-139StructuralconcreteNoneSBS-CA1NoneSBS-CA1,SBS-CA2,APP-CA1-105.0 NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 58of83 N EMO|etc. TABLE4A:LIGHTWEIGHTCONCRETEDECKS–NEWCONSTRUCTION OR REROOF(T EAR-O FF) SYSTEMTYPEA-1:BONDEDINSULATION,BONDEDROOFCOVER BaseInsulationLayerCoverboardRoofCover(Note15) Lightweight Concrete SystemDeck*MDP AttachAttach No.(Note1) (psf) (Note14) TypeTypeBasePlyPlyCapPly (Notes6,7,8)(Notes6,7,8) C ELCORE(NOA13-0307.02): A SPHALTOR T ORCH A PPLIED B ASE P LY: Min. 1.5-inch Polytherm, ACFoam II,Min. 0.25-inch(Optional) BP- StructuralMin. 200 psi, min. 2-inchBP-AA, SBS-SBS-AA, SBS- Polytherm G, ACFoam III, ENRGY 3, ISO 95+SECUROCKAA, SBS-AA, LWC-1CR-20CR-20-222.5 concreteCelcoreCellularConcreteGL, PolythermH, H-Shield, H-Shield CG, Multi-Gypsum-Fiber RoofAA,APP-TASBS-TA or APP-TA,APP-TA MaxFA3ormin. 2.0pcfInsulfoamBoardTA S ELF-A DHERING B ASE P LY: (Optional) StructuralMin. 200 psi, min. 2-inch(Optional)SBS-SBS-SA, APP- Additionallayersof LWC-2Min.1.5-inch,min.2.0pcfInsulfoamCR-20CR-20SBS-SA-222.5 concreteCelcoreCellularConcreteSASA baseinsulation Min. 1.5-inch Polytherm, ACFoam II, (Optional)(Optional)SBS-SBS-SA, APP- StructuralMin. 200 psi, min. 2-inchPolytherm G, ACFoam III, ENRGY 3, ISO 95+ AdditionallayersofSA, SBS-TA,SA, SBS-TA, LWC-3CR-20CR-20SBS-SA-222.5 concreteCelcoreCellularConcreteGL, Polytherm H, H-Shield, H-Shield CG, Multi- baseinsulationAPP-TAAPP-TA MaxFA3 Min. 1.5-inch Polytherm, ACFoam II,Min. 0.25-inch (Optional)SBS-SBS-SA, APP- StructuralMin. 200 psi, min. 2-inchPolytherm G, ACFoamIII, ENRGY 3, ISO 95+SECUROCK LWC-4CR-20CR-20SBS-SASA, SBS-TA,SA, SBS-TA,-222.5 concreteCelcoreCellularConcreteGL, Polytherm H, H-Shield, H-Shield CG, Multi-Gypsum-Fiber Roof APP-TAAPP-TA MaxFA3ormin.2.0pcfInsulfoamBoard H YBRID S YSTEMS WITH S ELF-A DHERING APPB ASE P LY: Min. 1.5-inch Polytherm, ACFoam II, (Optional) StructuralMin. 200 psi, min. 2-inchPolytherm G, ACFoam III, ENRGY 3, ISO 95+(Optional) APP- LWC-5CR-20AdditionallayersofCR-20APP-SA-HAPP-TA-222.5 concreteCelcoreCellularConcreteGL, PolythermH, H-Shield, H-Shield CG, Multi-TA baseinsulation MaxFA3 Min. 1.5-inch Polytherm, ACFoam II,Min. 0.25-inch StructuralMin. 200 psi, min. 2-inchPolytherm G, ACFoam III, ENRGY 3, ISO 95+SECUROCK(Optional) APP- LWC-6CR-20CR-20APP-SA-HAPP-TA-222.5 concreteCelcoreCellularConcreteGL, Polytherm H, H-Shield, H-Shield CG, Multi-Gypsum-Fiber RoofTA MaxFA3ormin.2.0pcfInsulfoamBoard H YBRID S YSTEMS WITH S ELF-A DHERING SBSB ASE P LY: Min. 1.5-inch Polytherm, ACFoam II, (Optional) StructuralMin. 200 psi, min. 2-inchPolytherm G, ACFoam III, ENRGY 3, ISO 95+(Optional)SBS- Additionallayersof LWC-7CR-20CR-20SBS-SA-HSBS-TA-222.5 concreteCelcoreCellularConcreteGL, PolythermH, H-Shield, H-Shield CG, Multi-TA baseinsulation MaxFA3 Min. 1.5-inch Polytherm, ACFoam II,Min. 0.25-inch Polytherm G, ACFoam III, ENRGY 3, ISO 95+SECUROCK StructuralMin. 200 psi, min. 2-inch(Optional)SBS- LWC-8CR-20CR-20SBS-SA-HSBS-TA-222.5 Gypsum-Fiber Roof concreteCelcoreCellularConcreteGL, Polytherm H, H-Shield, H-Shield CG, Multi-TA MaxFA3ormin.2.0pcfInsulfoamBoard NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 59of83 N EMO|etc. TABLE4A:LIGHTWEIGHTCONCRETEDECKS–NEWCONSTRUCTION OR REROOF(T EAR-O FF) SYSTEMTYPEA-1:BONDEDINSULATION,BONDEDROOFCOVER BaseInsulationLayerCoverboardRoofCover(Note15) Lightweight Concrete SystemDeck*MDP AttachAttach No.(Note1) (psf) (Note14) TypeTypeBasePlyPlyCapPly (Notes6,7,8)(Notes6,7,8) E LASTIZELL(NOA18-0208.03): A SPHALTOR T ORCH A PPLIED B ASE P LY: Min. 200 psi, min 2-inchMin. 0.25-inch(Optional) BP- StructuralMin.1.5-inchPolytherm,ACFoamII,ENRGY3,BP-AA, SBS-SBS-AA, SBS- Range II ElastizellSECUROCKAA, SBS-AA, LWC-9OB500OB500-225.0 concreteLightweight InsulatingISO95+ GL,Polytherm Hor H-ShieldGypsum-Fiber RoofAA,APP-TASBS-TAor APP-TA,APP-TA Concrete.BoardTA Min. 200 psi, min 2-inchMin. 1.5-inch Polytherm, ACFoam II,Min. 0.25-inch(Optional) BP- StructuralRangeIIElastizellPolytherm G, ACFoam III, ENRGY 3, ISO 95+SECUROCKBP-AA, SBS-AA, SBS-AA,SBS-AA, SBS- LWC-10CR-20CR-20-180.0 concreteLightweight InsulatingGL, PolythermH, H-Shield, H-Shield CG, Multi-Gypsum-Fiber RoofAA,APP-TASBS-TA or APP-TA,APP-TA Concrete.MaxFA3ormin.2.0pcfInsulfoamTA Board S ELF-A DHERING B ASE P LY: Min. 200 psi, min 2-inch (Optional) StructuralRange II Elastizell(Optional)SBS-SBS-SA, APP- LWC-11Min.1.5-inch,min.2.0pcfInsulfoamOB500AdditionallayersofOB500SBS-SA-120.0 concreteLightweight InsulatingSASA baseinsulation Concrete. Min. 200 psi, min 2-inchMin. 0.25-inch (Optional)SBS-SBS-SA, APP- StructuralRange II ElastizellSECUROCK SA, SBS-TA,SA, SBS-TA, LWC-12Min.1.5-inch,min.2.0pcfInsulfoamOB500OB500SBS-SA-120.0 concreteLightweight InsulatingGypsum-Fiber Roof APP-TAAPP-TA Concrete. Board Min. 200 psi, min 2-inch (Optional)(Optional)SBS-SBS-SA, APP- StructuralRange II ElastizellMin.1.5-inchPolytherm,ACFoamII,ENRGY3, LWC-13OB500AdditionallayersofOB500SBS-SASA, SBS-TA,SA, SBS-TA,-225.0 concreteLightweight InsulatingISO95+GL,Polytherm HorH-Shield baseinsulationAPP-TAAPP-TA Concrete. Min. 200 psi, min 2-inchMin. 0.25-inch (Optional)SBS-SBS-SA, APP- StructuralRange II ElastizellMin.1.5-inchPolytherm,ACFoamII,ENRGY3,SECUROCK LWC-14OB500OB500SBS-SASA, SBS-TA,SA, SBS-TA,-225.0 concreteLightweight InsulatingISO95+GL,Polytherm HorH-ShieldGypsum-Fiber Roof APP-TAAPP-TA Concrete.Board Min. 200 psi, min 2-inch (Optional) StructuralRange II Elastizell(Optional)SBS-SBS-SA, APP- Additionallayersof LWC-15Min.1.5-inch,min.2.0pcfInsulfoamCR-20CR-20SBS-SA-180.0 concreteLightweight InsulatingSASA baseinsulation Concrete. Min. 200 psi, min 2-inchMin. 1.5-inch Polytherm, ACFoam II, (Optional)(Optional)SBS-SBS-SA, APP- StructuralRange II ElastizellPolytherm G, ACFoam III, ENRGY 3, ISO 95+ LWC-16CR-20AdditionallayersofCR-20SBS-SASA, SBS-TA,SA, SBS-TA,-180.0 concreteLightweight InsulatingGL, PolythermH, H-Shield, H-Shield CG, Multi- baseinsulationAPP-TAAPP-TA Concrete.MaxFA3 NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 60of83 N EMO|etc. TABLE4A:LIGHTWEIGHTCONCRETEDECKS–NEWCONSTRUCTION OR REROOF(T EAR-O FF) SYSTEMTYPEA-1:BONDEDINSULATION,BONDEDROOFCOVER BaseInsulationLayerCoverboardRoofCover(Note15) Lightweight Concrete SystemDeck*MDP AttachAttach No.(Note1) (psf) (Note14) TypeTypeBasePlyPlyCapPly (Notes6,7,8)(Notes6,7,8) Min. 200 psi, min 2-inchMin. 1.5-inch Polytherm, ACFoam II,Min. 0.25-inch (Optional)SBS-SBS-SA, APP- StructuralRange II ElastizellPolytherm G, ACFoam III, ENRGY 3, ISO 95+SECUROCK SA, SBS-TA,SA, SBS-TA, LWC-17CR-20CR-20SBS-SA-180.0 concreteLightweight InsulatingGL, PolythermH, H-Shield, H-Shield CG, Multi-Gypsum-Fiber Roof APP-TAAPP-TA Concrete.MaxFA3ormin.2.0pcfInsulfoamBoard H YBRID S YSTEMS WITH S ELF-A DHERING APPB ASE P LY: Min. 200 psi, min 2-inchMin. 0.25-inch StructuralRange II ElastizellSECUROCK(Optional) APP- LWC-18Min.1.5-inch,min.2.0pcfInsulfoamOB500OB500APP-SA-HAPP-TA-120.0 concreteLightweight InsulatingGypsum-Fiber RoofTA Concrete.Board Min. 200 psi, min 2-inch (Optional) StructuralRange II ElastizellMin.1.5-inchPolytherm,ACFoamII,ENRGY3,(Optional) APP- Additionallayersof LWC-19OB500OB500APP-SA-HAPP-TA-225.0 concreteLightweight InsulatingISO95+GL,Polytherm HorH-ShieldTA baseinsulation Concrete. Min. 200 psi, min 2-inchMin. 0.25-inch StructuralRange II ElastizellMin.1.5-inchPolytherm,ACFoamII,ENRGY3,SECUROCK(Optional) APP- LWC-20OB500OB500APP-SA-HAPP-TA-225.0 concreteLightweight InsulatingISO95+GL,Polytherm HorH-ShieldGypsum-Fiber RoofTA Concrete.Board Min. 200 psi, min 2-inchMin. 1.5-inch Polytherm, ACFoam II, (Optional) StructuralRange II ElastizellPolytherm G, ACFoam III, ENRGY 3, ISO 95+(Optional) APP- Additionallayersof LWC-21CR-20CR-20APP-SA-HAPP-TA-180.0 concreteLightweight InsulatingGL, Polytherm H, H-Shield, H-Shield CG, Multi-TA baseinsulation Concrete.MaxFA3 Min. 200 psi, min 2-inchMin. 1.5-inch Polytherm, ACFoam II,Min. 0.25-inch StructuralRange II ElastizellPolytherm G, ACFoam III, ENRGY 3, ISO 95+SECUROCK(Optional) APP- LWC-22CR-20CR-20APP-SA-HAPP-TA-180.0 concreteLightweight InsulatingGL, Polytherm H, H-Shield, H-Shield CG, Multi-Gypsum-Fiber RoofTA Concrete.MaxFA3ormin.2.0 pcfInsulfoamBoard H YBRID S YSTEMS WITH S ELF-A DHERING SBSB ASE P LY: Min. 200 psi, min 2-inchMin. 0.25-inch StructuralRange II ElastizellSECUROCK(Optional)SBS- LWC-23Min.1.5-inch,min.2.0pcfInsulfoamOB500OB500SBS-SA-HSBS-TA-120.0 concreteLightweight InsulatingGypsum-Fiber RoofTA Concrete. Board Min. 200 psi, min 2-inch (Optional) StructuralMin.1.5-inchPolytherm,ACFoamII,ENRGY3,(Optional)SBS- Range II Elastizell LWC-24OB500AdditionallayersofOB500SBS-SA-HSBS-TA-225.0 concreteLightweight InsulatingISO95+GL,Polytherm HorH-ShieldTA baseinsulation Concrete. NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 61of83 N EMO|etc. TABLE4A:LIGHTWEIGHTCONCRETEDECKS–NEWCONSTRUCTION OR REROOF(T EAR-O FF) SYSTEMTYPEA-1:BONDEDINSULATION,BONDEDROOFCOVER BaseInsulationLayerCoverboardRoofCover(Note15) Lightweight Concrete SystemDeck*MDP AttachAttach No.(Note1) (psf) (Note14) TypeTypeBasePlyPlyCapPly (Notes6,7,8)(Notes6,7,8) Min. 200 psi, min 2-inchMin. 0.25-inch StructuralRange II ElastizellMin.1.5-inchPolytherm,ACFoamII,ENRGY3,SECUROCK(Optional)SBS- LWC-25OB500OB500SBS-SA-HSBS-TA-225.0 concreteLightweight InsulatingISO95+GL,Polytherm HorH-ShieldGypsum-Fiber RoofTA Concrete.Board Min. 200 psi, min 2-inchMin. 1.5-inch Polytherm, ACFoam II, (Optional) StructuralRange II ElastizellPolytherm G, ACFoam III, ENRGY 3, ISO 95+(Optional)SBS- LWC-26CR-20Additional layers ofCR-20SBS-SA-HSBS-TA-180.0 concreteLightweight InsulatingGL, Polytherm H, H-Shield, H-Shield CG, Multi-TA baseinsulation Concrete.MaxFA3 Min. 200 psi, min 2-inchMin. 1.5-inch Polytherm, ACFoam II,Min. 0.25-inch StructuralRange II ElastizellPolytherm G, ACFoam III, ENRGY 3, ISO 95+SECUROCK(Optional)SBS- LWC-27CR-20CR-20SBS-SA-HSBS-TA-180.0 concreteLightweight InsulatingGL, Polytherm H, H-Shield, H-Shield CG, Multi-Gypsum-Fiber RoofTA Concrete.MaxFA3ormin.2.0pcfInsulfoamBoard M EARLCRETE(NOA13-1007.09): A SPHALTOR T ORCH A PPLIED B ASE P LY: Min. 1.5-inch Polytherm, ACFoam II,Min. 0.25-inch(Optional) BP- StructuralMin. 200 psi, min. 2-inchPolytherm G, ACFoam III, ENRGY 3, ISO 95+SECUROCKBP-AA, SBS-AA, SBS-AA,SBS-AA, SBS- LWC-28CR-20CR-20-222.5 concreteMearlcreteGL, Polytherm H, H-Shield, H-Shield CG, Multi-Gypsum-Fiber RoofAA,APP-TASBS-TA or APP-TA,APP-TA MaxFA3ormin.2.0pcf InsulfoamBoardTA S ELF-A DHERING B ASE P LY: (Optional) StructuralMin. 200 psi, min. 2-inch(Optional)SBS-SBS-SA, APP- LWC-29Min.1.5-inch,min.2.0pcfInsulfoamCR-20AdditionallayersofCR-20SBS-SA-222.5 concreteMearlcreteSASA baseinsulation Min. 1.5-inch Polytherm, ACFoam II, (Optional)(Optional)SBS-SBS-SA, APP- StructuralMin. 200 psi, min. 2-inchPolytherm G, ACFoam III, ENRGY 3, ISO 95+ LWC-30CR-20AdditionallayersofCR-20SBS-SASA, SBS-TA,SA, SBS-TA,-222.5 concreteMearlcreteGL, PolythermH, H-Shield, H-Shield CG, Multi- baseinsulationAPP-TAAPP-TA MaxFA3 Min. 1.5-inch Polytherm, ACFoam II,Min. 0.25-inch (Optional)SBS-SBS-SA, APP- StructuralMin. 200 psi, min. 2-inchPolytherm G, ACFoam III, ENRGY 3, ISO 95+SECUROCK LWC-31CR-20CR-20SBS-SASA, SBS-TA,SA, SBS-TA,-222.5 concreteMearlcreteGL, Polytherm H, H-Shield, H-Shield CG, Multi-Gypsum-Fiber Roof APP-TAAPP-TA MaxFA3ormin.2.0pcfInsulfoam Board H YBRID S YSTEMS WITH S ELF-A DHERING APPB ASE P LY: Min. 1.5-inch Polytherm, ACFoam II, (Optional) StructuralMin. 200 psi, min. 2-inchPolytherm G, ACFoamIII, ENRGY 3, ISO 95+(Optional) APP- LWC-32CR-20AdditionallayersofCR-20APP-SA-HAPP-TA-222.5 concreteMearlcreteGL, Polytherm H, H-Shield, H-Shield CG, Multi-TA baseinsulation MaxFA3 NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 62of83 N EMO|etc. TABLE4A:LIGHTWEIGHTCONCRETEDECKS–NEWCONSTRUCTION OR REROOF(T EAR-O FF) SYSTEMTYPEA-1:BONDEDINSULATION,BONDEDROOFCOVER BaseInsulationLayerCoverboardRoofCover(Note15) Lightweight Concrete SystemDeck*MDP AttachAttach No.(Note1)(psf) (Note14) TypeTypeBasePlyPlyCapPly (Notes6,7,8)(Notes6,7,8) Min. 1.5-inch Polytherm, ACFoam II,Min. 0.25-inch StructuralMin. 200 psi, min. 2-inchPolytherm G, ACFoam III, ENRGY 3, ISO 95+SECUROCK(Optional) APP- LWC-33CR-20CR-20APP-SA-HAPP-TA-222.5 Gypsum-Fiber Roof concreteMearlcreteGL, PolythermH, H-Shield, H-Shield CG, Multi-TA MaxFA3ormin.2.0pcfInsulfoamBoard H YBRID S YSTEMS WITH S ELF-A DHERING SBSB ASE P LY: Min. 1.5-inch Polytherm, ACFoam II, (Optional) StructuralMin. 200 psi, min. 2-inchPolytherm G, ACFoam III, ENRGY 3, ISO 95+(Optional)SBS- Additionallayersof LWC-34CR-20CR-20SBS-SA-HSBS-TA-222.5 concreteMearlcreteGL, Polytherm H, H-Shield, H-Shield CG, Multi-TA baseinsulation MaxFA3 Min. 1.5-inch Polytherm, ACFoam II,Min. 0.25-inch StructuralMin. 200 psi, min. 2-inchPolytherm G, ACFoam III, ENRGY 3, ISO 95+SECUROCK(Optional)SBS- LWC-35CR-20CR-20SBS-SA-HSBS-TA-222.5 Gypsum-Fiber Roof concreteMearlcreteGL, PolythermH, H-Shield, H-Shield CG, Multi-TA MaxFA3ormin.2.0pcfInsulfoamBoard NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 63of83 N EMO|etc. TABLE4B:LIGHTWEIGHTCONCRETEDECKS–NEWCONSTRUCTION OR REROOF(T EAR-O FF) SYSTEMTYPEA-2:MECHANICALLYATTACHEDANCHORSHEET,BONDEDINSULATION,BONDEDROOFCOVER AnchorSheetBaseInsulationTopInsulationRoofCover(Note15) System‡DeckLightweight ConcreteMDP FastenAttachAttach No.(Note1)(Note14) (psf) TypeAttachTypeTypeBasePlyPlyCapPly (Note11)(Notes6,7,8)(Notes6,7,8) (Optional) Min.Min. 1.5-inch Thermaroof 7-incho.c.at Min.22(Optional if 1.5-inchComposite, Polytherm Min.300psi,min.2-inch4-inch lap ga.,TypeB,(Optionalif using AA Polytherm,Composite, or min. 0.5- Celcore CellularGAFGLASand7-inchSBS-AA, ventedOMG CR ACFoam II,inch Structodek High using AABase) BP- LWC-36Concrete, Elastizell#75 oro.c. in two,HAHASBS-TA,-45.0 Polytherm H, H-Density Fiberboard Roof steel atBSFPly) BP-AA,AA, SBS-AA, Lightweight Insulating ElastoventequallyAPP-TA Shield, Multi-Insulation or min. 0.75- max. 5 ftSBS-AASBS-TA or ConcreteorMearlcretespaced Max FA3 orinch Fesco Board spansAPP-TA centerrows Polytherm(homogeneous) 7-incho.c.at Min. 1.5-inch Min.22 Min.300psi,min.2-inch4-inch lap Polytherm, ga.,TypeB,(Optional)SBS-SA, Celcore CellularGAFGLASand7-inch ACFoam II, ventedOMG CR SBS-SA,APP-SA, Polytherm H, H- LWC-37Concrete, Elastizell#75 oro.c. in two,HANoneN/ASBS-SA-45.0 steel atBSFSBS-TA,SBS-TA, Shield, Multi- Lightweight InsulatingElastoventequally max. 5 ftAPP-TAAPP-TA Max FA3 or ConcreteorMearlcretespaced spans Polytherm centerrows 7-incho.c.at Min. 1.5-inch Min.22 Min.300psi,min.2-inch4-inch lap Polytherm, ga.,TypeB, Celcore CellularGAFGLASand7-inch ACFoam II, OMG CR(Optional) vented Polytherm H, H- LWC-38Concrete, Elastizell#75 oro.c. in two,HANoneN/AAPP-SA-HAPP-TA-45.0 steel atBSFAPP-TA Shield, Multi- Lightweight InsulatingElastoventequally max. 5 ft Max FA3 or ConcreteorMearlcrete spaced spans Polytherm centerrows 7-incho.c.at Min. 1.5-inch Min.22 Min.300psi,min.2-inchmin. 4-inch Polytherm, ga.,TypeB, GAFGLAS Celcore Cellularlap and 7- ACFoam II, ventedOMG CR(Optional) Polytherm H, H- LWC-39Concrete, Elastizell#75 orinch o.c. atHANoneN/ASBS-SA-HSBS-TA-45.0 steel at BSFSBS-TA Shield, Multi- Lightweight InsulatingElastoventtwo, equally max. 5 ft Max FA3 or ConcreteorMearlcretespaced spans Polytherm centerrows ‡NOTE:Forsteeldeckapplicationwherespecificdeckattachmentisnotreferenced,testedattachmentwas5/8”puddleweldswithweld-washersorTek/5screwsspaced6”o.c. NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 64of83 N EMO|etc. TABLE4C:LIGHTWEIGHTCONCRETEDECKS–NEWCONSTRUCTION OR REROOF(T EAR-O FF) SYSTEMTYPEE-2:MECHANICALLYATTACHEDBASESHEET,BONDEDROOFCOVER BaseSheet(NoteAbelow)RoofCover(Note15) SystemMDP ‡Deck(Note1)LightweightConcrete(Note14) Fasten No. (psf) TypeAttachBasePlyCapPly (Note11) P RE-E XISTENT C ELLULAR L IGHTWEIGHT I NSULATING C ONCRETE: Min.300psi,min.2-inchthickpre- existent cellular LWC.Note: To Min.22ga.,typeBsteelatmax qualify the LWIC under this 7-inch o.c. in a 3-inch lap and 7-inch o.c. in two,(Optional) SBS-AA, APP- LWC-405 ft spans or structural assembly, an OMG CR BPF shall B3orB11OMGCRBPFequally spaced, staggered rows in the field of theBP-AA, SBS--45.0 TA concrete achieve an average withdrawal of sheetAA 53 lbf when tested per TAS 105 or ANSI/SPRIFX-1 C ELCORE(NOA13-0307.02): A SPHALTOR T ORCH A PPLIED B ASE P LY: Min.22ga.,typeBsteelatmaxTrufast FM-907-inch o.c. in a 3-inch lap and 7-inch o.c. in two, Min.200psi,min.2-inchthickBP-AA, SBS- LWC-415 ft spans or structuralB1throughB11or OMG CRequallyspaced,staggeredrowsinthefieldoftheSBS-AA-45.0 CelcoreAA concreteBPFsheet Min. 26 ga., type HF steel atB1, B2, B3, B4,9-inch o.c. in a 3-inch lap and 9-inch o.c. in two, Min.225psi,min.2-inchthickBP-AA, SBS- max 5 ft spans or structuralB7, B8, B10 orequallyspaced,staggeredrowsinthefieldofthe LWC-42OMGCRBPFSBS-AA-45.0 CelcoreMFAA concreteB11sheet Min.22ga.,typeB steelatmaxB1, B2, B3, B4,7-inch o.c. in a 3-inch lap and 14-inch o.c. in two, Min.225psi,min.2-inchthickBP-AA, SBS- LWC-436 ft spans or structuralB7, B8, B10 orOMGCRBPFequally spaced, staggered rows in the field of theSBS-AA-45.0 CelcoreMFAA concreteB11sheet Min.22ga.,typeBsteelatmaxB1, B2, B3, B4,9-inch o.c.in a 3-inch lap and 9-inch o.c. in two, Min.225psi,min.2-inchthickBP-AA, SBS- 6 ft spans or structuralB7, B8, B10 orequallyspaced,staggeredrowsinthefieldofthe LWC-44OMGCRBPFSBS-AA-45.0 CelcoreMFAA concreteB11sheet Min.22ga.,typeBsteelatmax9-inch o.c. in a 4-inch lap and 18-inch o.c. in two,BP-AA, SBS-SBS-AA, SBS- Min.225psi,min.2-inchthickTrufast Twin LWC-455 ft spans or structuralB1,B2orB11equally spaced, staggered rows in the field of theAA,SBS-TAorTA, or APP--45.0 Loc-Nail CelcoreMF concretesheetAPP-TATA Min.22ga.,typeBsteelatmaxBP-AA, SBS-SBS-AA, SBS- Min.300psi,min.2-inchthick8-incho.c.ina4-inchlapand8-incho.c.inthree 5 ft spans or structuralAA,SBS-TAorTA, or APP- LWC-46B2orB11TrufastFM-90-60.0 equallyspaced,staggeredcenterrows CelcoreMF concreteAPP-TATA Min.22ga.,typeBsteelatmax Min.300psi,min.2-inchthickB2 (with poly-8-incho.c.ina4-inchlapand8-incho.c.inthreeSBS-TA orSBS-TA or 5 ft spans or structural LWC-47TrufastFM-90-60.0 CelcoreMF filmtopsurface)equallyspaced,staggeredcenterrowsAPP-TAAPP-TA concrete Min.22ga.,typeBsteelatmaxTrufast FM-907-inch o.c.in a 3-inch lap and 7-inch o.c. in two,BP-AA, SBS- Min.300psi,min.2-inchthickSBS-AA, APP- LWC-485 ft spans or structuralB1throughB11or OMG CRequallyspaced,staggeredrowsinthefieldoftheAA, SBS-TA,-75.0 CelcoreTA concreteBPFsheetAPP-TA NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 65of83 N EMO|etc. TABLE4C:LIGHTWEIGHTCONCRETEDECKS–NEWCONSTRUCTION OR REROOF(T EAR-O FF) SYSTEMTYPEE-2:MECHANICALLYATTACHEDBASESHEET,BONDEDROOFCOVER BaseSheet(NoteAbelow)RoofCover(Note15) SystemMDP ‡Deck(Note1)LightweightConcrete(Note14) Fasten No. (psf) TypeAttachBasePlyCapPly (Note11) (Optional) Min.22ga.,typeBsteelatmax Min.300psi,min.2-inchthickTrufast FM-10-incho.c.ina4-inchlapand10-incho.c.inthreeBP-AA,SBS-SBS-AA, SBS- 5 ft spans or structural LWC-49ElastobaseP-90.0 CelcoreMF290equallyspaced,staggeredcenter rowsAA,SBS-TAorTA,APP-TA concrete APP-TA S ELF-A DHERING B ASE P LY: Min.22ga.,typeBsteelatmax9-inch o.c. in a 4-inch lap and 18-inch o.c. in two,SBS-SA, APP- Min.225psi,min.2-inchthickB2 (with poly-Trufast Twin LWC-505 ft spans or structuralequally spaced, staggered rows in the field of theSBS-SASA, SBS-TA-45.0 CelcoreMF filmtopsurface)Loc-Nail concretesheetorAPP-TA Min.22ga.,typeBsteelatmaxSBS-SA, APP- Min.300psi,min.2-inchthickB2 (with poly-8-incho.c.ina4-inchlapand8-incho.c.inthree 5 ft spans or structuralSA, SBS-TA LWC-51TrufastFM-90SBS-SA-60.0 CelcoreMF filmtopsurface)equallyspaced,staggeredcenterrows concreteorAPP-TA H YBRID S YSTEMS WITH S ELF-A DHERING APPB ASE P LY: Min.22ga.,typeBsteelatmax9-inch o.c.in a 4-inch lap and 18-inch o.c. in two, Min.225psi,min.2-inchthickB2 (with poly-Trufast Twin LWC-525 ft spans or structuralequally spaced, staggered rows in the field of theAPP-SA-HAPP-TA-45.0 CelcoreMF filmtopsurface)Loc-Nail concretesheet Min.22ga.,typeBsteelatmax Min.300psi,min.2-inchthickB2 (with poly-8-incho.c.ina4-inchlapand8-incho.c.inthree LWC-535 ft spans or structuralTrufastFM-90APP-SA-HAPP-TA-60.0 equallyspaced,staggeredcenterrows CelcoreMF filmtopsurface) concrete H YBRID S YSTEMS WITH S ELF-A DHERING SBSB ASE P LY: Min. 225 psi, min. 2-inch thick Min.22ga.,typeBsteelatmax 9-inch o.c.at a min. 4-inch lap and 18-inch o.c. at CelcoreMFCellularConcretewithB2 (with poly-Trufast Twin LWC-545 ft spans or structuralSBS-SA-HSBS-TA-45.0 two,equallyspaced,staggeredrowsinthefieldof Celcore HS Rheology Modifying filmtopsurface)Loc-Nail concretethesheet Admixture Min. 300 psi, min. 2-inch thick Min.22ga.,typeBsteelatmax CelcoreMFCellularConcretewithB2 (with poly-8-inch o.c. at a min. 4-inch lap and 8-inch o.c. at LWC-555 ft spans or structuralTrufastFM-90SBS-SA-HSBS-TA-60.0 Celcore HS Rheology Modifying filmtopsurface)threeequallyspaced,staggeredcenterrows concrete Admixture E LASTIZELL(NOA18-0208.03): A SPHALTOR T ORCH A PPLIED B ASE P LY: Min.22ga.,typeBsteelatmaxTrufast FM-907-inch o.c.in a 3-inch lap and 7-inch o.c. in two,BP-AA, SBS-SBS-AA, SBS- Min.200psi,min.2-inchthick 5 ft spans or structuralor OMG CRequallyspaced,staggeredrowsinthefieldoftheAA, SBS-TA,TA, or APP- LWC-56B1throughB11-45.0 ElastizellRange II concreteBPFsheetorAPP-TATA Min.22ga.,typeBsteelatmaxTrufast FM-907-inch o.c. in a 3-inch lap and 7-inch o.c. in two, Min.200psi,min.2-inchthickB2 (with poly-SBS-TA orSBS-TA or 5 ft spans or structuralor OMG CRequallyspaced,staggeredrowsinthefieldofthe LWC-57-45.0 ElastizellRange II filmtopsurface)APP-TAAPP-TA concreteBPFsheet NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 66of83 N EMO|etc. TABLE4C:LIGHTWEIGHTCONCRETEDECKS–NEWCONSTRUCTION OR REROOF(T EAR-O FF) SYSTEMTYPEE-2:MECHANICALLYATTACHEDBASESHEET,BONDEDROOFCOVER BaseSheet(NoteAbelow)RoofCover(Note15) SystemMDP ‡Deck(Note1)LightweightConcrete(Note14) Fasten No. (psf) TypeAttachBasePlyCapPly (Note11) Min. 350 psi, min. 2-inch thick (Optional) Min.22ga.,typeBventedElastizellwith Zell-Crete Fibers,Elastobase P8-inch o.c. in a 4-inch lap and 8-inch o.c. in three,SBS-AA, SBS- Trufast FM- BP-AA, SBS- LWC-58steel at max 5 ft spans orsupplemental attached with(with poly-film equally spaced, staggered rows in the fieldof theTA, or APP--52.5 290AA, SBS-TA, structuralconcreteRoofgrip #21 and 3-inch plates at 1 topsurface)sheetTA orAPP-TA per8ft2 Min. 350 psi, min. 2-inch thick SBS-AA, SBS- Min.22ga.,typeBsteelatmaxElastizellwith Zell-Crete Fibers,Trufast Twin6-inch o.c. in a 4-inch lap and 6-inch o.c. in three, BP-AA orTA, SBS-SA, LWC-595 ft spans or structuralsupplemental attached withB2orB11Loc-Nailsequally spaced, staggered rows in the field of the-60.0 SBS-AAAPP-TA or concreteRoofgrip #21 and 3-inch plates at 1(min.1.8-inch)sheet APP-SA per8ft2 Min. 350 psi, min. 2-inch thick Min.22ga.,typeBsteelatmaxElastizell with Zell-Crete Fibers,Trufast Twin6-inch o.c. in a 4-inch lap and 6-inch o.c. in three, B2 (with poly-SBS-TA orSBS-TA or LWC-605 ft spans or structuralsupplemental attached withLoc-Nailsequally spaced, staggered rows in the field of the-60.0 filmtopsurface)APP-TAAPP-TA concreteRoofgrip #21 and 3-inch plates at 1(min.1.8-inch)sheet per8ft2 S ELF-A DHERING B ASE P LY: Min.22ga.,typeBsteelatmaxTrufast FM-907-inch o.c.in a 3-inch lap and 7-inch o.c. in two,SBS-SA, APP- Min.200psi,min.2-inchthickB2 (with poly- LWC-615 ft spans or structuralor OMG CRequallyspaced,staggeredrowsinthefieldoftheSBS-SASA, SBS-TA-45.0 ElastizellRange II filmtopsurface) concreteBPFsheetorAPP-TA Min. 350 psi, min. 2-inch thick Min.22ga.,typeBsteelatmaxElastizell with Zell-Crete Fibers,Trufast Twin6-inch o.c. in a 4-inch lap and 6-inch o.c. in three,SBS-SA, APP- B2 (with poly- LWC-625 ft spans or structuralsupplemental attached withLoc-Nailsequally spaced, staggered rows in the field of theSBS-SASA, SBS-TA-60.0 filmtopsurface) concreteRoofgrip #21 and 3-inch plates at 1(min.1.8-inch)sheetorAPP-TA per8ft2 H YBRID S YSTEMS WITH S ELF-A DHERING APPB ASE P LY: Min.22ga.,typeBsteelatmaxTrufast FM-907-inch o.c. in a 3-inch lap and 7-inch o.c. in two, Min.200psi,min.2-inchthickB2 (with poly- LWC-635 ft spans or structuralor OMG CRequallyspaced,staggeredrowsinthefieldoftheAPP-SA-HAPP-TA-45.0 ElastizellRange II filmtopsurface) concreteBPFsheet Min. 350 psi, min. 2-inch thick Min.22ga.,typeBsteelatmaxElastizell with Zell-Crete Fibers,Trufast Twin6-inch o.c. in a 4-inch lap and 6-inch o.c. in three, B2 (with poly- LWC-645 ft spans or structuralsupplemental attached withLoc-Nailsequally spaced, staggered rows in the field of theAPP-SA-HAPP-TA-60.0 filmtopsurface) concreteRoofgrip #21 and 3-inch plates at 1(min.1.8-inch)sheet per8ft2 H YBRID S YSTEMS WITH S ELF-A DHERING SBSB ASE P LY: NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 67of83 N EMO|etc. TABLE4C:LIGHTWEIGHTCONCRETEDECKS–NEWCONSTRUCTION OR REROOF(T EAR-O FF) SYSTEMTYPEE-2:MECHANICALLYATTACHEDBASESHEET,BONDEDROOFCOVER BaseSheet(NoteAbelow)RoofCover(Note15) SystemMDP ‡Deck(Note1)LightweightConcrete(Note14) Fasten No. (psf) TypeAttachBasePlyCapPly (Note11) Min.22ga.,typeBsteelatmaxMin. 200 psi, min. 2-inch thickTrufast FM-907-inch o.c. at a min. 3-inch lap and 7-inch o.c. at two, B2 (with poly- LWC-655 ft spans or structuralRange II Elastizell Lightweightor OMG CRequally spaced, staggered rows in the field of theSBS-SA-HSBS-TA-45.0 filmtopsurface) concreteInsulatingConcreteBPFsheet Min. 350 psi, min. 2-inch thick Min.22ga.,typeBsteelatmaxElastizell with Zell-Crete Fibers,Trufast Twin6-inch o.c. at a min. 4-inch lap and 6-inch o.c. at B2 (with poly- LWC-665 ft spans or structuralsupplemental attached withLoc-Nailsthree,equallyspaced,staggeredrowsinthefieldofSBS-SA-HSBS-TA-60.0 filmtopsurface) concreteRoofgrip #21 and 3-inch plates at 1(min.1.8-inch)thesheet per8ft2 M EARLCRETE(NOA13-1007.09): A SPHALTOR T ORCH A PPLIED B ASE P LY: Min.22ga.,typeBsteelatmaxTrufast FM-907-inch o.c. in a 4-inch lap and 7-inch o.c. in two,BP-AA, SBS-SBS-AA, SBS- Min.300psi,min.2-inchthickB1,B2,B3,B7or LWC-675 ft spans or structuralor OMG CRequallyspaced,staggeredrowsinthefieldoftheAA, SBS-TA,TA, or APP--52.5 MearlcreteB11 concreteBPFsheetorAPP-TATA Min.22ga.,typeBsteelatmaxTrufast FM-907-inch o.c. in a 4-inch lap and 7-inch o.c. in two, Min.300psi,min.2-inchthickB2 (with poly-SBS-TA orSBS-TA or 5 ft spans or structuralor OMG CRequallyspaced,staggeredrowsinthefieldofthe LWC-68-52.5 Mearlcrete filmtopsurface)APP-TAAPP-TA concreteBPFsheet S ELF-A DHERING B ASE P LY: Min.22ga.,typeBsteelatmaxTrufast FM-907-inch o.c. in a 4-inch lap and 7-inch o.c. in two,SBS-SA, APP- Min.300psi,min.2-inchthickB2 (with poly- LWC-695 ft spans or structuralor OMG CRequallyspaced,staggeredrowsinthefieldoftheSBS-SASA, SBS-TA-52.5 Mearlcrete filmtopsurface) concreteBPFsheetorAPP-TA H YBRID S YSTEMS WITH S ELF-A DHERING APPB ASE P LY: Min.22ga.,typeBsteelatmaxTrufast FM-907-inch o.c. in a 4-inch lap and 7-inch o.c. in two, Min.300psi,min.2-inchthickB2 (with poly- 5 ft spans or structuralor OMG CRequallyspaced,staggeredrowsinthefieldofthe LWC-70APP-SA-HAPP-TA-52.5 Mearlcrete filmtopsurface) concreteBPFsheet H YBRID S YSTEMS WITH S ELF-A DHERING SBSB ASE P LY: Min.22ga.,typeBsteelatmaxTrufast FM-907-inch o.c. at a min. 4-inch lap and 7-inch o.c. at two, Min.300psi,min.2-inchthickB2 (with poly- 5 ft spans or structuralor OMG CRequally spaced, staggered rows in the field of the LWC-71SBS-SA-HSBS-TA-52.5 Mearlcrete filmtopsurface) concreteBPFsheet ‡NOTE:Forsteeldeckapplicationwherespecificdeckattachmentisnotreferenced,tested attachmentwas5/8”puddleweldswithweld-washersorTek/5screwsspaced6”o.c.SeeNote1. A.BaseSheetsoptionsinTable4Carecodedasfollows: B1:PolyglassG2Base;B2:ElastobaseorElastobaseP;B3:GAFGLAS #75;B4:GAFGLASStrataventNailableVentingBaseSheet;B5:GAFGLASPly4;B6:GAFGLASFlexPly6;B7:JMPermaPlyNo.28;B8:JM Vensulation;B9: JMGlasPly IV; B10:JMGlasPly Premier;B11: Elastovent NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 68of83 N EMO|etc. TABLE5A:CEMENTITIOUSWOODFIBERDECKS–REROOF(T EAR-O FF) SYSTEMTYPEA-1:BONDEDINSULATION,BONDEDROOFCOVER BaseInsulationLayerTopInsulationLayerRoofCover(Note15) System*MDP Deck(Notes1& 12) AttachAttach No. (psf) TypeTypeBasePlyPlyCapPly (Notes6,7,8)(Notes6,7,8) A SPHALTOR T ORCH A PPLIED B ASE P LY: Min. 0.25-inch Dens Deck, Dens Deck(Optional) BP- Min.1.5-inchPolytherm, Existing Min. 2.5-inch Tectum Plank orD-IS orPrime, SECUROCK Gypsum-Fiber RoofD-IS orBP-AA,AA, SBS-AA,SBS-AA, SBS- ACFoamII,ISO 95+GL, CWF-1-45.0 TectumLS PlankOB500Boardormin.0.5-inchStructodekHighOB500SBS-AASBS-TAorAPP-TA,APP-TA PolythermH,H-Shield,ENRGY-3 DensityFiberboardRoofInsulationTA Min.1.5-inchPolytherm,Min. 0.25-inch Dens Deck, Dens DeckSBS-TA ExistingMin.2.5-inchTectumPlankorD-IS orD-IS or(Optional)SBS-SBS-TA, APP- ACFoamII,ISO 95+GL,Prime, SECUROCK Gypsum-Fiber Roof CWF-2or APP--45.0 TectumLS PlankOB500OB500TAorAPP-TATA PolythermH,H-Shield,ENRGY-3Board TA ExistingMin.2-inchTectumPlankorMin. 0.25-inch Dens Deck, Dens Deck(Optional) BP- Min.1.5-inchPolytherm, Tectum LS Plank; 2 ft span; three (3)Prime, SECUROCK Gypsum-Fiber RoofBP-AA,AA, SBS-AA,SBS-AA, SBS- CWF-3ACFoamII,ISO 95+GL,CR-20CR-20-52.5 SBS-AATA,APP-TA evenly spaced #15 screws with 2”Boardormin.0.5-inchStructodekHighSBS-TAorAPP- PolythermH,H-Shield,ENRGY-3 diameterplates perjoistDensityFiberboardRoofInsulationTA ExistingMin.2-inchTectumPlankor Min.1.5-inchPolytherm,Min. 0.25-inch Dens Deck, Dens DeckSBS-TA Tectum LS Plank; 2 ft span; three (3)(Optional)SBS-SBS-TA, APP- CWF-4ACFoamII,ISO 95+GL,CR-20Prime, SECUROCK Gypsum-Fiber RoofCR-20or APP--52.5 evenly spaced #15 screws with 2”TAorAPP-TATA PolythermH,H-Shield,ENRGY-3BoardTA diameterplates perjoist S ELF-A DHERING B ASE P LY: Min.1.5-inchPolytherm,Min. 0.25-inch Dens Deck, Dens Deck(Optional)SBS-SBS-SA, APP- ExistingMin.2.5-inchTectumPlankorD-IS orD-IS or CWF-5ACFoamII,ISO 95+GL,Prime, SECUROCK Gypsum-Fiber RoofSBS-SASA, SBS-TA orSA, SBS-TA,-45.0 TectumLS PlankOB500 OB500 PolythermH,H-Shield,ENRGY-3BoardAPP-TAAPP-TA ExistingMin.2-inchTectumPlankor Min. 1.5-inch Polytherm,Min. 0.25-inch Dens Deck, Dens Deck(Optional)SBS-SBS-SA, APP- Tectum LS Plank; 2 ft span; three (3) CWF-6ACFoamII,ISO 95+GL,CR-20Prime, SECUROCK Gypsum-Fiber RoofCR-20SBS-SASA, SBS-TA orSA, SBS-TA,-52.5 evenly spaced #15 screws with 2” PolythermH,H-Shield,ENRGY-3BoardAPP-TAAPP-TA diameterplates perjoist H YBRID S YSTEMSWITH S ELF-A DHERING APPB ASE P LY: Min.1.5-inchPolytherm,Min. 0.25-inch Dens Deck, Dens Deck ExistingMin.2.5-inchTectumPlankorD-IS orD-IS orAPP-SA-(Optional)APP- ACFoamII,ISO 95+GL,Prime, SECUROCK Gypsum-Fiber Roof CWF-7APP-TA-45.0 TectumLS PlankOB500OB500HTA PolythermH,H-Shield,ENRGY-3Board ExistingMin.2-inchTectumPlankor Min.1.5-inchPolytherm,Min. 0.25-inch Dens Deck, Dens Deck Tectum LS Plank; 2 ft span; three (3)APP-SA-(Optional)APP- Prime, SECUROCK Gypsum-Fiber Roof CWF-8ACFoamII,ISO 95+GL,CR-20CR-20APP-TA-52.5 evenly spaced #15 screws with 2”HTA PolythermH,H-Shield,ENRGY-3Board diameterplates perjoist H YBRID S YSTEMSWITH S ELF-A DHERING SBSB ASE P LY: NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 69of83 N EMO|etc. TABLE5A:CEMENTITIOUSWOODFIBERDECKS–REROOF(T EAR-O FF) SYSTEMTYPEA-1:BONDEDINSULATION,BONDEDROOFCOVER BaseInsulationLayerTopInsulationLayerRoofCover(Note15) System*MDP Deck(Notes1& 12) AttachAttach No.(psf) TypeTypeBasePlyPlyCapPly (Notes6,7,8)(Notes6,7,8) Min.1.5-inchPolytherm,Min. 0.25-inch Dens Deck, Dens Deck ExistingMin.2.5-inchTectumPlankorD-IS orD-IS orSBS-SA-(Optional)SBS- CWF-9ACFoamII,ISO 95+GL,Prime, SECUROCK Gypsum-Fiber RoofSBS-TA-45.0 OB500 TectumLS PlankOB500HTA Board PolythermH,H-Shield,ENRGY-3 ExistingMin.2-inchTectumPlankor Min.1.5-inchPolytherm,Min. 0.25-inch Dens Deck, Dens Deck SBS-SA-(Optional)SBS- Tectum LS Plank; 2 ft span; three (3) WF-10ACFoamII,ISO 95+GL,CR-20Prime, SECUROCK Gypsum-Fiber RoofCR-20SBS-TA-52.5 evenly spaced #15 screws with 2”HTA Board PolythermH,H-Shield,ENRGY-3 diameterplates perjoist TABLE5B:CEMENTITIOUSWOODFIBERDECKS–REROOF(T EAR-O FF)OR R ECOVER SYSTEMTYPEA-2:MECHANICALLYATTACHEDANCHORSHEET,BONDEDINSULATION,BONDEDROOFCOVER AnchorSheetBaseInsulationTopInsulationRoofCover(Note15) Deck SystemMDP FastenAttachAttach No.(psf) (Note1) TypeAttachTypeTypeBasePlyPlyCapPly (Note11)(Notes6,7,8)(Notes6,7,8) A SPHALTOR T ORCH A PPLIED B ASE P LY: Min. 0.25-inch Dens Deck, Elastobase, Existing Min.9-inch o.c. in 4-inchMin. 1.5-inch Polytherm, Dens Deck Prime, SECUROCK Elastobase(Optional)SBS- 2.5-inchTrufastlap and 18-inch o.c.ACFoam II, Polytherm G, Gypsum-Fiber Roof Board, P,BP-AA, BP-AA, SBS-AA, Min. 0.75-inch Fesco Board C WF-11Tectum PlankTwinin two, equallyACFoamIII,ISO95+GL,HotasphaltHotasphalt-45.0* ElastoventSBS-AAAA, SBS-TASBS-TA, (homogeneous) or min. 0.5- or Tectum LS Loc-Nailspaced, staggeredPolytherm H, H-Shield, or PolyglassorAPP-TAAPP-TA inch Structodek High Density PlankcenterrowsENRGY3orMulti-MaxFA3, G2Base FiberboardRoofInsulation Elastobase, Existing Min.9-inch o.c. in 4-inchMin. 1.5-inch Polytherm,SBS-TA, ElastobaseMin.0.25-inchDensDeck,(Optional) 2.5-inchTrufastlap and 18-inch o.c.ACFoam II, Polytherm G,SBS-TA SBS-SA, P,Dens Deck Prime,SBS-TA, C WF-12Tectum PlankTwinin two, equallyACFoamIII,ISO95+GL,HotasphaltHotasphaltAPP--45.0* or APP- ElastoventSECUROCK Gypsum-FiberSBS-SA or or Tectum LS Loc-Nailspaced, staggeredPolytherm H, H-Shield,TATA, RoofBoardAPP-TA or Polyglass PlankcenterrowsENRGY3orMulti-MaxFA3,APP-SA G2Base S ELF-A DHERING B ASE P LY: Elastobase, Existing Min.9-inch o.c. in 4-inchMin. 1.5-inch Polytherm,SBS-TA, ElastobaseMin.0.25-inchDensDeck,(Optional) 2.5-inchlap and 18-inch o.c.ACFoam II, Polytherm G,SBS-SA, Trufast P,Dens Deck Prime,SBS-TA, CTectum Plank WF-13Twinin two, equallyACFoamIII,ISO95+GL,HotasphaltHotasphaltSBS-SAAPP--45.0* ElastoventSECUROCK Gypsum-FiberSBS-SA or or Tectum LSLoc-Nailspaced, staggeredTA, Polytherm H, H-Shield, or PolyglassRoofBoardAPP-TA PlankcenterrowsENRGY3orMulti-MaxFA3,APP-SA G2Base H YBRID S YSTEMSWITH S ELF-A DHERING APPB ASE P LY: NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 70of83 N EMO|etc. TABLE5B:CEMENTITIOUSWOODFIBERDECKS–REROOF(T EAR-O FF)OR R ECOVER SYSTEMTYPEA-2:MECHANICALLYATTACHEDANCHORSHEET,BONDEDINSULATION,BONDEDROOFCOVER AnchorSheetBaseInsulationTopInsulationRoofCover(Note15) Deck SystemMDP FastenAttachAttach No.(psf) (Note1) TypeAttachTypeTypeBasePlyPlyCapPly (Note11)(Notes6,7,8)(Notes6,7,8) Elastobase, Existing Min.9-inch o.c. in 4-inchMin. 1.5-inch Polytherm, ElastobaseMin.0.25-inchDensDeck, 2.5-inchTrufastlap and 18-inch o.c. ACFoam II, Polytherm G, APP-SA-(Optional) P,Dens Deck Prime, C WF-14Tectum PlankTwinin two, equallyACFoamIII,ISO95+GL,HotasphaltHotasphaltAPP-TA-45.0* Elastovent SECUROCK Gypsum-FiberHAPP-TA or Tectum LS Loc-Nailspaced, staggeredPolytherm H, H-Shield, or PolyglassRoofBoard PlankcenterrowsENRGY3orMulti-MaxFA3, G2Base H YBRID S YSTEMSWITH S ELF-A DHERING SBSB ASE P LY: Elastobase, Existing Min.9-incho.c.atmin.4-Min. 1.5-inch Polytherm, ElastobaseMin.0.25-inchDensDeck, 2.5-inchinchlapand18-inchACFoam II, Polytherm G, Trufast P,Dens Deck Prime,SBS-SA-(Optional) C Tectum Plank WF-15Twino.c. at two, equallyACFoamIII,ISO95+GL,HotasphaltHotasphaltSBS-TA-45.0* ElastoventSECUROCK Gypsum-FiberHSBS-TA or Tectum LSLoc-Nail spaced, staggeredPolythermH, H-Shield, or PolyglassRoofBoard PlankcenterrowsENRGY3orMulti-MaxFA3, G2Base TABLE5C:CEMENTITIOUSWOODFIBERDECKS–REROOF(T EAR-O FF)OR RECOVER SYSTEMTYPEB-1:MECHANICALLYATTACHEDBASEINSULATION,BONDEDTOPINSULATION,BONDEDROOFCOVER BaseInsulationLayerTopInsulationLayerRoofCover(Note15) Deck System MDP(psf) Attach No. (Note1) TypeFasten(Note11)AttachTypeBasePlyPlyCapPly (Notes6,7,8) Existing Min. 2.5-inchMin. 2-inch H-OMG Polymer GypTec PlateMin. 0.5-inch Structodek(Optional if(Optional if using AASBS-AA, 1per CWF-16Tectum Plank orShield orwithPolymerGypTecorTrufastHigh Density FiberboardHotasphaltusing AA Ply)Base) BP-AA, SBS-AA,SBS-TA,-45.0* 2 4.0ft TectumLSPlankPolythermHTL3in.PlatewithTLFastenerRoofInsulationBP-AA,SBS-AASBS-TAorAPP-TAAPP-TA NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 71of83 N EMO|etc. TABLE 5D: CEMENTITIOUS WOOD FIBER DECKS –REROOF (T EAR-O FF) OR RECOVER SYSTEMTYPEC-1:MECHANICALLYATTACHEDINSULATION,BONDEDROOFCOVER TopInsulationLayerRoofCover(Note15) DeckBase Insulation Layer System MDP(psf) No. (Note1)(Note13) TypeFasten(Note11)AttachBasePlyPlyCapPly Existing Min. 2.5-(Optional) One orMin. 0.25-inch Dens Deck, Dens Deck Prime or Trufast Twin Loc-(Optional if(Optional if using AASBS-AA, inch Tectummore layers, anySECUROCKGypsum-FiberRoofBoardormin.0.5-1per CWF-17using AA Ply)Base) BP-AA, SBS-AA,SBS-TA,-45.0* Nails (min. 1-inch 2 Plank or Tectumcombination, looseinch Structodek High Density Fiberboard Roof 2.0ft BP-AA,SBS-AASBS-TAorAPP-TAAPP-TA embedment) LSPlanklaidInsulation TABLE5E:CEMENTITIOUSWOODFIBERDECKS–REROOF(T EAR-O FF) SYSTEMTYPEE-2:NON-INSULATED,MECHANICALLYATTACHEDBASESHEET,BONDEDROOFCOVER BaseSheetRoofCover(Note15) Deck System MDP(psf) No. (Note1) TypeFasten(Note11)AttachBasePlyCapPly Existing Min. 2.5-inch Elastobase,ElastobaseP,Polyglass9-inch o.c. in 4-inch lap and 18-inch o.c. in(Optional)BP-AA,SBS-SBS-AA, SBS- TectumPlankorTectum CWF-18TrufastTwinLoc-Nails-45.0* G2Basetwo,equallyspaced,staggeredcenterrowsAA,SBS-TAorAPP-TATA,APP-TA LSPlank NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 72of83 N EMO|etc. TABLE6A:GYPSUMDECKS–REROOF(T EAR-O FF) SYSTEMTYPEA-1:BONDEDINSULATION,BONDEDROOFCOVER BaseInsulationLayerTopInsulationLayerRoofCover(Note15) System*MDP Deck(Notes1&12) AttachAttach No. (psf) TypeTypeBasePlyPlyCapPly (Notes6,7,8)(Notes6,7,8) A SPHALT-OR T ORCH-A PPLIED B ASE P LY: (Optional (Optional if using Existing, soundif usingSBS-AA, Min.0.25-inchDensDeck,DensDeckPrimeorAA Base) BP-AA, G-1poured gypsum orCR-20NoneN/AAA Ply)SBS-TA,-245.0 SBS-AA,SBS-TAor SECUROCKGypsum-FiberRoof Board gypsumplankdeckBP-AA,APP-TA APP-TA SBS-AA S ELF-A DHERING B ASE P LY: SBS-SA, Existing, sound Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3,(Optional) SBS-SA,APP-SA, G-2poured gypsum orOB500Min.0.25-inchDensDeckPrimeOB500SBS-SA-72.5 PolythermHorH-Shieldormin.2.0pcf,InsulfoamSBS-TA,APP-TASBS-TA, gypsumplankdeck APP-TA Existing, sound (Optional)additionallayers(s)ofSBS-SA, G-3poured gypsum orMin.1.5-inchmin.2.0pcf,InsulfoamOB500OB500SBS-SA(Optional)SBS-SA-112.5 baseinsulationAPP-SA gypsumplankdeck SBS-SA, Existing, sound Min.1.5-inchPolytherm,ACFoamII,ENRGY3,(Optional)additionallayers(s)of(Optional) SBS-SA,APP-SA, poured gypsum or G-4OB500OB500SBS-SA-112.5 PolythermHor H-ShieldbaseinsulationSBS-TA,APP-TASBS-TA, gypsumplankdeck APP-TA SBS-SA, Existing, sound Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3,Min.0.25-inchSECUROCKGypsum-(Optional) SBS-SA,APP-SA, poured gypsum or G-5OB500OB500SBS-SA-112.5 PolythermHorH-Shieldormin.2.0pcf,InsulfoamFiberRoofBoardSBS-TA,APP-TASBS-TA, gypsumplankdeck APP-TA SBS-SA, Existing, sound APP-SA, Min.1.5-inchPolytherm,ACFoamII,ENRGY3,H-(Optional) SBS-SA, G-6poured gypsum orM-OSFAMin.0.25-inchDensDeckPrimeM-OSFASBS-SA-72.5 SBS-TA, ShieldorMulti-Max FA3SBS-TA,APP-TA gypsumplankdeck APP-TA (Optional) additional layers(s) ofSBS-SA, Existing, sound Min.1.5-inchPolytherm,ACFoamII,ENRGY3,H-base insulation and/or min. 0.25-(Optional) SBS-SA,APP-SA, G-7poured gypsum orM-OSFAM-OSFASBS-SA-202.5 ShieldorMulti-Max FA3SBS-TA,APP-TA inchSECUROCKGypsum-FiberRoofSBS-TA, gypsumplankdeck BoardAPP-TA Min.1.5-inch,min.2.0pcfInsulfoam,Polytherm,SBS-SA, Existing, sound ACFoam II, Polytherm G, ACFoam III, ENRGY 3,(Optional) SBS-SA,APP-SA, G-8poured gypsum orCR-20Min.0.25-inchDensDeckPrimeCR-20SBS-SA-72.5 Polytherm H, H-Shield, H-Shield CG or Multi-MaxSBS-TA,APP-TASBS-TA, gypsumplankdeck FA3APP-TA NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 73of83 N EMO|etc. TABLE6A:GYPSUMDECKS–REROOF(T EAR-O FF) SYSTEMTYPEA-1:BONDEDINSULATION,BONDEDROOFCOVER BaseInsulationLayerTopInsulationLayerRoofCover(Note15) System*MDP Deck(Notes1&12) AttachAttach No. (psf) TypeTypeBasePlyPlyCapPly (Notes6,7,8)(Notes6,7,8) Existing, sound (Optional)additionallayersofbase G-9poured gypsum orMin.1.5-inch,min.2.0pcfInsulfoamCR-20CR-20SBS-SA(Optional)SBS-SASBS-SA-240.0 insulation gypsumplankdeck SBS-SA, Existing, sound Min.0.25-inchSECUROCKGypsum-(Optional) SBS-SA,APP-SA, G-10poured gypsum orMin.1.5-inch,min.2.0pcfInsulfoamCR-20CR-20SBS-SA-240.0 FiberRoofBoardSBS-TA,APP-TASBS-TA, gypsumplankdeck APP-TA (Optional) additional layers(s) ofSBS-SA, Existing, soundMin.1.5-inchPolytherm,ACFoamII,PolythermG, base insulation and/or min. 0.25-(Optional) SBS-SA,APP-SA, G-11poured gypsum orACFoam III, ENRGY 3, Polytherm H, H-Shield, H-CR-20CR-20SBS-SA-257.5 inchSECUROCKGypsum-FiberRoofSBS-TA,APP-TASBS-TA, gypsumplankdeckShieldCGorMulti-Max FA3 BoardAPP-TA H YBRID S YSTEMSWITH S ELF-A DHERING APPB ASE P LY: Existing, sound Min.1.5-inchPolytherm,ACFoamII,ENRGY3,(Optional)additionallayers(s)of poured gypsum or G-12OB500OB500APP-SA-H(Optional)APP-TAAPP-TA-112.5 PolythermHor H-Shieldbaseinsulation gypsumplankdeck Existing, sound Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3,Min.0.25-inchSECUROCKGypsum- G-13poured gypsum orOB500OB500APP-SA-H(Optional)APP-TAAPP-TA-112.5 FiberRoofBoard PolythermHorH-Shieldormin.2.0pcf,Insulfoam gypsumplankdeck (Optional) additional layers(s) of Existing, sound Min.1.5-inchPolytherm,ACFoamII,ENRGY3,H-base insulation and/or min. 0.25- G-14poured gypsum orM-OSFAM-OSFAAPP-SA-H(Optional)APP-TAAPP-TA-202.5 ShieldorMulti-Max FA3inchSECUROCKGypsum-FiberRoof gypsumplankdeck Board Existing, sound Min.0.25-inchSECUROCKGypsum- poured gypsum or G-15Min.1.5-inch,min.2.0pcfInsulfoamCR-20CR-20APP-SA-H(Optional)APP-TAAPP-TA-240.0 FiberRoofBoard gypsumplankdeck (Optional) additional layers(s) of Existing, soundMin.1.5-inchPolytherm,ACFoamII,PolythermG, base insulation and/or min. 0.25- poured gypsum orACFoam III, ENRGY 3, Polytherm H, H-Shield, H- G-16CR-20CR-20APP-SA-H(Optional)APP-TAAPP-TA-257.5 inchSECUROCKGypsum-FiberRoof gypsumplankdeckShieldCGorMulti-Max FA3 Board H YBRID S YSTEMSWITH S ELF-A DHERING SBSB ASE P LY: Existing, sound Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, poured gypsum or G-17OB500Min.0.25-inchDensDeckPrimeOB500SBS-SA-H(Optional)SBS-TASBS-TA-72.5 PolythermHorH-Shieldormin.2.0pcf,Insulfoam gypsumplank Existing, sound Min.1.5-inchPolytherm,ACFoamII,ENRGY3,(Optional)additionallayers(s)of poured gypsum or G-18OB500OB500SBS-SA-H(Optional)SBS-TASBS-TA-112.5 baseinsulation PolythermHor H-Shield gypsumplank NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 74of83 N EMO|etc. TABLE6A:GYPSUMDECKS–REROOF(T EAR-O FF) SYSTEMTYPEA-1:BONDEDINSULATION,BONDEDROOFCOVER BaseInsulationLayerTopInsulationLayerRoofCover(Note15) System*MDP Deck(Notes1&12) AttachAttach No. (psf) TypeTypeBasePlyPlyCapPly (Notes6,7,8)(Notes6,7,8) Existing, sound Min. 1.5-inch Polytherm, ACFoamII, ENRGY 3,Min.0.25-inchSECUROCKGypsum- G-19poured gypsum orOB500OB500SBS-SA-H(Optional)SBS-TASBS-TA-112.5 FiberRoofBoard PolythermHorH-Shieldormin.2.0pcf,Insulfoam gypsumplank Existing, sound Min.1.5-inchPolytherm,ACFoamII,ENRGY3,H- poured gypsum or G-20M-OSFAMin.0.25-inchDensDeckPrimeM-OSFASBS-SA-H(Optional)SBS-TASBS-TA-72.5 ShieldorMulti-Max FA3 gypsumplank (Optional) additional layers(s) of Existing, sound Min.1.5-inchPolytherm,ACFoamII,ENRGY3,H-base insulation and/or min. 0.25- G-21poured gypsum orM-OSFAM-OSFASBS-SA-H(Optional)SBS-TASBS-TA-202.5 ShieldorMulti-Max FA3inchSECUROCKGypsum-FiberRoof gypsumplank Board Min. 1.5-inch, min. 2.0 pcf EPS insulation board, Existing, sound Polytherm, ACFoam II, Polytherm G, ACFoam III, G-22poured gypsum orCR-20Min.0.25-inchDensDeckPrimeCR-20SBS-SA-H(Optional)SBS-TASBS-TA-72.5 ENRGY 3, Polytherm H, H-Shield, H-Shield CG or gypsumplank Multi-MaxFA3 Existing, sound Min.0.25-inchSECUROCKGypsum- G-23poured gypsum orMin.1.5-inch,min.2.0pcfInsulfoamCR-20CR-20SBS-SA-H(Optional)SBS-TASBS-TA-240.0 FiberRoofBoard gypsumplank (Optional) additional layers(s) of Existing, soundMin.1.5-inchPolytherm,ACFoamII,PolythermG, base insulation and/or min. 0.25- G-24poured gypsum orACFoam III, ENRGY 3, Polytherm H, H-Shield, H-CR-20CR-20SBS-SA-H(Optional)SBS-TASBS-TA-257.5 inchSECUROCKGypsum-FiberRoof gypsumplankShieldCGorMulti-Max FA3 Board C OLD A PPLIED B ASE P LY: Min. 0.25-inch Dens Deck, Dens Deck Min. 1-inch Polytherm, ACFoam II, Polytherm G, Prime, DEXcell FA Glass Mat Roof Board, Existing, soundACFoam III, EnergyGuard Polyiso Insulation, ENRGYSBS-CA1, SECUROCK Gypsum-Fiber Roof Board or SBS-CA1,(Optional) SBS-CA1, SECUROCK Glass-Mat Roof Board, min. G-25poured gypsum or3, PolythermH, H-Shield ISO 95+ GL, Multi-MaxM-OSFAM-OSFASBS-CA2,-120.0 SBS-CA2SBS-CA2 7/16-inch DEXcell Cement Roof Board or gypsumplankdeckFA3, RESISTA or UltraMax or min. 2-inchAPP-CA1 min. 0.5-inch SECUROCK Cement Roof DECKMATEPlusorDECKMATE PlusFA Board Min. 1-inch Polytherm or ACFoam II, Polytherm G,Min. 0.25-inch Dens Deck Prime or Existing, soundACFoam III, EnergyGuard Polyiso Insulation, ENRGYDEXcell FA Glass Mat Roof Board,SBS-CA1, G-26poured gypsum or3, Polytherm H, H-Shield, ISO 95+ GL, Multi-MaxM-OSFAmin.7/16-inchDEXcellCementRoofM-OSFASBS-CA1NoneSBS-CA2,-127.5 gypsumplankdeckFA3, RESISTA or UltraMax or min. 2-inchBoard or min. 0.5-inch SECUROCKAPP-CA1 DECKMATEPlusorDECKMATE PlusFACement Roof Board NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 75of83 N EMO|etc. TABLE6A:GYPSUMDECKS–REROOF(T EAR-O FF) SYSTEMTYPEA-1:BONDEDINSULATION,BONDEDROOFCOVER BaseInsulationLayerTopInsulationLayerRoofCover(Note15) System*MDP Deck(Notes1&12) AttachAttach No. (psf) TypeTypeBasePlyPlyCapPly (Notes6,7,8)(Notes6,7,8) Min. 1-inch Polytherm or ACFoam II, Polytherm G, Existing, soundACFoam III, EnergyGuard Polyiso Insulation, ENRGYSBS-CA1, Min.0.25-inchSECUROCKGypsum-SBS-CA1, G-27poured gypsum or3, Polytherm H, H-Shield, ISO 95+ GL, Multi-MaxM-OSFAM-OSFANoneSBS-CA2,-127.5 FiberRoofBoardSBS-CA2 gypsumplankdeckFA3, RESISTA or UltraMax or min. 2-inchAPP-CA1 DECKMATEPlusorDECKMATE PlusFA Min. 0.25-inch Dens Deck, Dens Deck Min. 1-inch Polytherm or ACFoam II, Polytherm G, Prime, DEXcellFA Glass Mat Roof Board, ACFoam III, EnergyGuard Polyiso Insulation, ENRGY Existing, sound SECUROCK Gypsum-Fiber Roof Board or SBS-CA1,SBS-CA1, SECUROCK Glass-Mat Roof Board, min. G-28poured gypsum or3, Polytherm H, H-Shield, ISO 95+ GL, Multi-MaxM-OSFAM-OSFANone-202.5 SBS-CA2SBS-CA2 7/16-inch DEXcell Cement Roof Board or FA3, RESISTA or UltraMax or min. 2-inch gypsumplankdeck min. 0.5-inch SECUROCK Cement Roof DECKMATEPlusorDECKMATE PlusFA Board Min. 0.25-inch Dens Deck Prime, Existing, soundMin.1-inchPolytherm,ACFoamII,PolythermG, SBS-CA1, DEXcellFAGlassMatRoofBoardorSBS-CA1,(Optional) SBS-CA1, G-29poured gypsum orACFoam III, ENRGY 3, Polytherm H, H-Shield orOB500OB500SBS-CA2,-112.5 SECUROCK Gypsum-Fiber RoofSBS-CA2SBS-CA2 gypsumplankdeckMulti-MaxFA3 APP-CA1 Board Existing, soundMin.1-inchPolytherm,ACFoamII,PolythermG,Min.0.25-inchDensDeckPrimeorSBS-CA1, SBS-CA1,(Optional) SBS-CA1, poured gypsum orACFoam III, ENRGY 3, PolythermH, H-Shield orSECUROCK Gypsum-Fiber RoofSBS-CA2, G-30CR-20CR-20-120.0 SBS-CA2SBS-CA2 gypsumplankdeckMulti-MaxFA3BoardAPP-CA1 Existing, soundMin.1-inchPolytherm,ACFoamII,PolythermG,SBS-CA1, Min.0.25-inchDensDeckPrimeor G-31poured gypsum orACFoam III, ENRGY 3, Polytherm H, H-Shield orCR-20CR-20SBS-CA1NoneSBS-CA2,-127.5 DEXcellFAGlassMatRoofBoard gypsumplankdeckMulti-MaxFA3APP-CA1 Existing, soundMin.1-inchPolytherm,ACFoamII,PolythermG,SBS-CA1, Min.0.25-inchSECUROCKGypsum-SBS-CA1, poured gypsum orACFoam III, ENRGY 3, Polytherm H, H-Shield orSBS-CA2, G-32CR-20CR-20None-127.5 FiberRoofBoardSBS-CA2 gypsumplankdeckMulti-MaxFA3APP-CA1 Existing, soundMin.0.25-inchDensDeckPrimeor Min. 1-inch ENRGY 3, Polytherm H, H-Shield, Multi-SBS-CA1,SBS-CA1, G-33poured gypsum orCR-20SECUROCK Gypsum-Fiber RoofCR-20None-232.5 MaxFA3SBS-CA2SBS-CA2 gypsumplankdeckBoard NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 76of83 N EMO|etc. TABLE6B:GYPSUMDECKS–REROOF(T EAR-O FF) SYSTEMTYPEA-2:MECHANICALLYATTACHEDANCHORSHEET,BONDEDINSULATION,BONDEDROOFCOVER AnchorSheetBaseInsulationTopInsulationRoofCover(Note15) Deck SystemMDP AttachAttach Fasten No.(psf) (Note1) TypeAttachTypeTypeBasePlyPlyCapPly (Notes(Notes (Note11) 6,7,8)6,7,8) Elastobase,9-inch o.c. in 4-Min. 1.5-inch Polytherm,Min. 0.25-inch Dens Deck, Dens Existing, Elastobaseinchlapand18-ACFoam II, Polytherm G,Deck Prime, SECUROCK Gypsum-(Optional) sound pouredTrufast FM-75SBS-AA, HotHotBP-AA, P,inch o.c. in two,ACFoamIII,ISO95+GL,Fiber Roof Board, Min. 0.75-inchBP-AA, SBS- gypsum orSBS-TA, G-34or FM-90 or-45.0* Elastoventequally spaced,PolythermH, H-Shield,asphaltFesco Board (homogeneous) orasphaltSBS-AAAA, SBS-TA gypsum plank TwinLoc-NailsAPP-TA or PolyglassstaggeredENRGY 3, Polytherm ormin. 0.5-inch Structodek HighorAPP-TA deck G2BasecenterrowsMulti-MaxFA3DensityFiberboardRoofInsulation TABLE6C:GYPSUMDECKS–REROOF(T EAR-O FF)OR RECOVER SYSTEMTYPEC-1:MECHANICALLYATTACHEDINSULATION,BONDEDROOFCOVER TopInsulationLayerRoofCover(Note15) DeckBase Insulation Layer System MDP(psf) No. (Note1)(Note13) TypeFasten(Note11)AttachBasePlyPlyCapPly (Optional) One orMin. 0.25-inch Dens Deck, Dens Deck Prime or Existing soundTrufast Twin Loc-(Optional if(Optional if using AASBS-AA, more layers, anySECUROCKGypsum-FiberRoofBoardormin.0.5-1per G-35poured gypsum orNails (min. 1-inchusing AA Ply)Base) BP-AA, SBS-AA,SBS-TA,-45.0* 2 combination, looseinch Structodek High Density Fiberboard Roof2.0ft gypsumplankdeckBP-AA,SBS-AASBS-TAorAPP-TAAPP-TA embedment) laidInsulation TABLE6D:GYPSUMDECKS–REROOF(T EAR-O FF) SYSTEMTYPEE-2:NON-INSULATED,MECHANICALLYATTACHEDBASESHEET,BONDEDROOFCOVER BaseSheetRoofCover(Note15) Deck System MDP(psf) No. (Note1) TypeFasten(Note11)AttachBasePlyCapPly Existing sound pouredElastobase, Elastobase P,9-inch o.c. in 4-inch lap and 18-inch o.c. TrufastFM-75 or FM-(Optional)BP-AA,SBS-AA,SBS-TAorSBS-AA, SBS-TA, G-36gypsum or gypsum plankElastoventorPolyglassG2intwo,equallyspaced,staggeredcenter-45.0* 90orTwinLoc-NailsAPP-TAAPP-TA deckBaserows NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 77of83 N EMO|etc. TABLE7A:RECOVERAPPLICATIONS SYSTEMTYPEA-1:BONDEDINSULATION,BONDEDROOFCOVER BaseInsulationLayerTopInsulationLayerRoofCover(Note15) Substrate System*MDP AttachAttach No. (psf) (Notes1&12) TypeTypeBasePlyPlyCapPly (Notes6,7,8)(Notes6,7,8) A SPHALTOR T ORCH A PPLIED B ASE P LY: Min. 0.25-inch Dens Deck, Dens DeckBP-AA, SBS- Existing asphaltic(Optional)BP-AA,SBS-SBS-AA, SBS-TA Prime or SECUROCK Gypsum-Fiber RoofAA, SBS-TA, R-1Min.1.5-inchMulti-MaxFA3D-ISD-IS-67.5 roof AA,SBS-TAorAPP-TAorAPP-TA BoardAPP-TA Min. 0.25-inch Dens Deck, Dens DeckBP-AA, SBS- Existing asphalticMin. 1.5-inch Polytherm, ACFoam II or(Optional)BP-AA,SBS-SBS-AA, SBS-TA, Prime or SECUROCK Gypsum-Fiber RoofAA, SBS-TA, R-2D-ISD-IS-90.0 roofENRGY3ormin.2.0pcfInsulfoamAA,SBS-TAorAPP-TAorAPP-TA BoardAPP-TA Min. 0.25-inch Dens Deck, Dens DeckBP-AA, SBS- Existing asphalticMin.1.5-inchPolytherm,ACFoamII,(Optional)BP-AA,SBS-SBS-AA, SBS-TA, R-3OB500Prime or SECUROCK Gypsum-Fiber RoofOB500AA, SBS-TA,-127.5 roofENRGY3,H-Shield orISO95+GL AA,SBS-TAorAPP-TAorAPP-TA BoardAPP-TA BP-AA, SBS- Existing asphalticMin. 1.5-inch Polytherm, ACFoam II,Min.0.25-inchSECUROCKGypsum-Fiber(Optional)BP-AA,SBS-SBS-AA, SBS-TA, AA, SBS-TA, R-4M-OSFAM-OSFA-157.5 roofENRGY3,H-ShieldorMulti-MaxFA3RoofBoardAA,SBS-TAorAPP-TAorAPP-TA APP-TA Min. 1.5-inch Ultra-Max or Multi-Max FA-3, min. 1.3-inch Polytherm G, Existing asphalticMin.0.25-inchSECUROCKGypsum-FiberBP-AA, SBS-(Optional)BP-AA,SBS- R-5ACFoamIIIormin.1.0-inchISO95+GL,CR-20CR-20SBS-AA-225.0 roofRoofBoardAAAA Polytherm H, H-Shield, H-Shield CG or ENRGY3ormin.2.0pcfInsulfoam Min. 1.5-inch Ultra-Max or Multi-Max FA-3, min. 1.3-inch Polytherm G, Existing asphalticMin.0.25-inchSECUROCKGypsum-Fiber R-6CR-20CR-20APP-TA(Optional)APP-TAAPP-TA-232.5 ACFoamIIIormin.1.0-inchISO95+GL, roofRoofBoard Polytherm H, H-Shield, H-Shield CG or ENRGY3ormin.2.0pcfInsulfoam S ELF-A DHERING B ASE P LY: (Optional) additional layers(s) of base Existing asphalticinsulation and/or min. 0.25-inch(Optional) SBS-SA,SBS-SA,APP-SA, R-7Min.1.5-inchMulti-MaxFA3D-ISD-ISSBS-SA-67.5 roofSECUROCKGypsum-FiberRoofBoardorSBS-TA,APP-TASBS-TA,APP-TA DensDeckPrime Min. 1.5-inch Polytherm, ACFoam II, Existing asphaltic(Optional) SBS-SA,SBS-SA,APP-SA, ENRGY3orMulti-MaxFA3ormin.2.0 R-8D-ISMin.0.25-inchDensDeckPrimeD-ISSBS-SA-72.5 roofSBS-TA,APP-TASBS-TA,APP-TA pcfInsulfoam Existing asphaltic(Optional)additionallayers(s)ofbase R-9Min.1.5-inchmin.2.0pcfInsulfoamD-ISD-ISSBS-SA(Optional)SBS-SASBS-SA-90.0 roofinsulation Existing asphalticMin.0.25-inchSECUROCKGypsum-Fiber(Optional) SBS-SA,SBS-SA,APP-SA, R-10Min.1.5-inchmin.2.0pcfInsulfoamD-ISD-ISSBS-SA-90.0 roofRoofBoardSBS-TA,APP-TASBS-TA,APP-TA NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 78of83 N EMO|etc. TABLE7A:RECOVERAPPLICATIONS SYSTEMTYPEA-1:BONDEDINSULATION,BONDEDROOFCOVER BaseInsulationLayerTopInsulationLayerRoofCover(Note15) Substrate System*MDP AttachAttach No. (psf) (Notes1&12) TypeTypeBasePlyPlyCapPly (Notes6,7,8)(Notes6,7,8) (Optional)additionallayers(s)ofbase Existing asphalticMin. 1.5-inch Polytherm, ACFoam II or(Optional) SBS-SA,SBS-SA,APP-SA, R-11D-ISinsulation and/or min. 0.25-inchD-ISSBS-SA-90.0 roofENRGY3SBS-TA,APP-TASBS-TA,APP-TA SECUROCKGypsum-FiberRoofBoard Min. 1.5-inch Polytherm, ACFoam II, Existing asphaltic(Optional) SBS-SA,SBS-SA,APP-SA, ENRGY 3, Polytherm H or H-Shield or R-12OB500Min.0.25-inchDensDeckPrimeOB500SBS-SA-72.5 roofSBS-TA,APP-TASBS-TA,APP-TA min.2.0pcfInsulfoam Existing asphaltic(Optional)additionallayersofbase R-13Min.1.5-inch,min.2.0pcfInsulfoamOB500OB500SBS-SA(Optional)SBS-SASBS-SA-120.0 roofinsulation Existing asphalticMin.0.25-inchSECUROCKGypsum-Fiber(Optional) SBS-SA,SBS-SA,APP-SA, R-14Min.1.5-inch,min.2.0pcfInsulfoamOB500OB500SBS-SA-120.0 roofRoofBoardSBS-TA,APP-TASBS-TA,APP-TA (Optional)additionallayers(s)ofbase Existing asphalticMin.1.5-inchPolytherm,ACFoamII,(Optional) SBS-SA,SBS-SA,APP-SA, insulation and/or min. 0.25-inch R-15OB500OB500SBS-SA-127.5 roofENRGY3,PolythermHorH-ShieldSBS-TA,APP-TASBS-TA,APP-TA SECUROCKGypsum-FiberRoofBoard Existing asphalticMin. 1.5-inch Polytherm, ACFoam II,(Optional) SBS-SA,SBS-SA,APP-SA, R-16M-OSFAMin.0.25-inchDensDeckPrimeM-OSFASBS-SA-72.5 roofENRGY3,H-ShieldorMulti-MaxFA3SBS-TA,APP-TASBS-TA,APP-TA (Optional)additionallayers(s)ofbase Existing asphalticMin. 1.5-inch Polytherm, ACFoam II,(Optional) SBS-SA,SBS-SA,APP-SA, insulation and/or min. 0.25-inch R-17M-OSFAM-OSFASBS-SA-157.5 roofENRGY3,H-ShieldorMulti-MaxFA3SBS-TA,APP-TASBS-TA,APP-TA SECUROCKGypsum-FiberRoofBoard Min. 1.5-inch min. 2.0 pcf Insulfoam, Min.2-inchPolytherm,ACFoamII,min. Existing asphaltic(Optional) SBS-SA,SBS-SA,APP-SA, 1.5-inch Ultra-Max or Multi-Max FA-3, R-18CR-20Min.0.25-inchDensDeckPrimeCR-20SBS-SA-72.5 roofmin. 1.3-inch Polytherm G, ACFoam IIISBS-TA,APP-TASBS-TA,APP-TA or min. 1.0-inch ISO 95+GL, Polytherm H,H-Shield,H-ShieldCGorENRGY3 Existing asphaltic(Optional)additionallayers(s)ofbase R-19Min.1.5-inchmin.2.0pcfInsulfoamCR-20CR-20SBS-SA(Optional)SBS-SASBS-SA-240.0 roofinsulation Existing asphalticMin.0.25-inchSECUROCKGypsum-Fiber(Optional) SBS-SA,SBS-SA,APP-SA, R-20Min.1.5-inchmin.2.0pcfInsulfoamCR-20CR-20SBS-SA-240.0 roofRoofBoardSBS-TA,APP-TASBS-TA,APP-TA (Optional if Top Layer Insulation installed) Min. 1.5-inch Ultra-Max or(Optional if Base Layer Insulation Existing asphaltic(Optional) SBS-SA,SBS-SA,APP-SA, Multi-Max FA-3, min. 1.3-inchinstalled) additional layers(s) of base R-21CR-20CR-20SBS-SA-240.0 Polytherm G, ACFoamIII or min. 1.0-insulation and/or min. 0.25-inch roofSBS-TA,APP-TASBS-TA,APP-TA inch ISO 95+GL, Polytherm H, H-Shield,SECUROCKGypsum-FiberRoofBoard H-ShieldCGorENRGY3 NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 79of83 N EMO|etc. TABLE7A:RECOVERAPPLICATIONS SYSTEMTYPEA-1:BONDEDINSULATION,BONDEDROOFCOVER BaseInsulationLayerTopInsulationLayerRoofCover(Note15) Substrate System*MDP AttachAttach No. (psf) (Notes1&12) TypeTypeBasePlyPlyCapPly (Notes6,7,8)(Notes6,7,8) (Optional if Top Layer Insulation(Optional if Base Layer Insulation Existing asphalticinstalled) Min. 2-inch Polytherm,installed) additional layers(s) of base(Optional) SBS-SA,SBS-SA,APP-SA, R-22CR-20CR-20SBS-SA-247.5 roofACFoamII, ENRGY-3, Polytherm H or H-insulation and/or min. 0.25-inchSBS-TA,APP-TASBS-TA,APP-TA ShieldSECUROCKGypsum-FiberRoofBoard H YBRID S YSTEMSWITH S ELF-A DHERING APPB ASE P LY: (Optional) additional layers(s) of base Existing asphalticinsulation and/or min. 0.25-inch R-23Min.1.5-inchMulti-MaxFA3D-ISD-ISAPP-SA-H(Optional)APP-TAAPP-TA-67.5 roofSECUROCKGypsum-FiberRoofBoardor DensDeckPrime Existing asphalticMin.0.25-inchSECUROCKGypsum-Fiber R-24Min.1.5-inchmin.2.0pcfInsulfoamD-ISD-ISAPP-SA-H(Optional)APP-TAAPP-TA-90.0 roofRoofBoard (Optional)additionallayers(s)ofbase Existing asphalticMin. 1.5-inch Polytherm, ACFoam II or R-25D-ISinsulation and/or min. 0.25-inchD-ISAPP-SA-H(Optional)APP-TAAPP-TA-90.0 roofENRGY3 SECUROCKGypsum-FiberRoofBoard Existing asphalticMin.0.25-inchSECUROCKGypsum-Fiber R-26Min.1.5-inch,min.2.0pcfInsulfoamOB500OB500APP-SA-H(Optional)APP-TAAPP-TA-120.0 roofRoofBoard (Optional)additionallayers(s)ofbase Existing asphalticMin.1.5-inchPolytherm,ACFoamII, R-27OB500insulation and/or min. 0.25-inchOB500APP-SA-H(Optional)APP-TAAPP-TA-127.5 roofENRGY3,PolythermHorH-Shield SECUROCKGypsum-FiberRoofBoard (Optional)additionallayers(s)ofbase Existing asphalticMin. 1.5-inch Polytherm, ACFoam II, insulation and/or min. 0.25-inch R-28M-OSFAM-OSFAAPP-SA-H(Optional)APP-TAAPP-TA-157.5 roofENRGY3,H-ShieldorMulti-MaxFA3 SECUROCKGypsum-FiberRoofBoard Min. 1.5-inch Ultra-Max or Multi-Max FA-3, min. 1.3-inch Polytherm G,(Optional)additionallayers(s)ofbase Existing asphaltic R-29ACFoamIIIormin.1.0-inchISO95+GL,CR-20insulation and/or min. 0.25-inchCR-20APP-SA-H(Optional)APP-TAAPP-TA-240.0 roof Polytherm H, H-Shield, H-Shield CG orSECUROCKGypsum-FiberRoofBoard ENRGY3 (Optional)additionallayers(s)ofbase Existing asphalticMin. 2-inch Polytherm, ACFoam II, insulation and/or min. 0.25-inch R-30CR-20CR-20APP-SA-H(Optional)APP-TAAPP-TA-247.5 roofENRGY-3,PolythermHorH-Shield SECUROCKGypsum-FiberRoofBoard H YBRID S YSTEMSWITH S ELF-A DHERING SBSB ASE P LY: (Optional) additional layers(s) of base Existing asphalticinsulation and/or min. 0.25-inch R-31Min.1.5-inchMulti-MaxFA3D-ISD-ISSBS-SA-H(Optional)SBS-TASBS-TA-67.5 roofSECUROCKGypsum-FiberRoofBoardor DensDeckPrime NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 80of83 N EMO|etc. TABLE7A:RECOVERAPPLICATIONS SYSTEMTYPEA-1:BONDEDINSULATION,BONDEDROOFCOVER BaseInsulationLayerTopInsulationLayerRoofCover(Note15) Substrate System*MDP AttachAttach No. (psf) (Notes1&12) TypeTypeBasePlyPlyCapPly (Notes6,7,8)(Notes6,7,8) Min. 1.5-inch Polytherm, ACFoam II, Existing asphaltic R-32ENRGY3orMulti-MaxFA3ormin.2.0D-ISMin.0.25-inchDensDeckPrimeD-ISSBS-SA-H(Optional)SBS-TASBS-TA-72.5 roof pcfInsulfoam Existing asphalticMin.0.25-inchSECUROCKGypsum-Fiber R-33Min.1.5-inchmin.2.0pcfInsulfoamD-ISD-ISSBS-SA-H(Optional)SBS-TASBS-TA-90.0 roofRoofBoard (Optional)additionallayers(s)ofbase Existing asphalticMin. 1.5-inch Polytherm, ACFoam II or insulation and/or min. 0.25-inch R-34D-ISD-ISSBS-SA-H(Optional)SBS-TASBS-TA-90.0 roofENRGY3 SECUROCKGypsum-FiberRoofBoard Min. 1.5-inch Polytherm, ACFoam II, Existing asphaltic ENRGY 3, Polytherm H or H-Shield or R-35OB500Min.0.25-inchDensDeckPrimeOB500SBS-SA-H(Optional)SBS-TASBS-TA-72.5 roof min.2.0pcfInsulfoam Existing asphalticMin.0.25-inchSECUROCKGypsum-Fiber R-36Min.1.5-inch,min.2.0pcfInsulfoamOB500OB500SBS-SA-H(Optional)SBS-TASBS-TA-120.0 roofRoofBoard (Optional)additionallayers(s)ofbase Existing asphalticMin.1.5-inchPolytherm,ACFoamII, R-37OB500insulation and/or min. 0.25-inchOB500SBS-SA-H(Optional)SBS-TASBS-TA-127.5 roofENRGY3,PolythermHorH-Shield SECUROCKGypsum-FiberRoofBoard Existing asphalticMin. 1.5-inch Polytherm, ACFoamII, R-38M-OSFAMin.0.25-inchDensDeckPrimeM-OSFASBS-SA-H(Optional)SBS-TASBS-TA-72.5 roofENRGY3,H-ShieldorMulti-MaxFA3 (Optional)additionallayers(s)ofbase Existing asphalticMin. 1.5-inch Polytherm, ACFoam II, R-39M-OSFAinsulation and/or min. 0.25-inchM-OSFASBS-SA-H(Optional)SBS-TASBS-TA-157.5 roofENRGY3,H-ShieldorMulti-MaxFA3 SECUROCKGypsum-FiberRoofBoard Min. 1.5-inch min. 2.0 pcf Insulfoam, Min.2-inchPolytherm,ACFoamII,min. Existing asphaltic1.5-inch Ultra-Max or Multi-Max FA-3, R-40CR-20Min.0.25-inchDensDeckPrimeCR-20SBS-SA-H(Optional)SBS-TASBS-TA-72.5 roofmin. 1.3-inch Polytherm G, ACFoam III or min. 1.0-inch ISO 95+GL, Polytherm H,H-Shield,H-ShieldCGorENRGY3 Existing asphalticMin.0.25-inchSECUROCKGypsum-Fiber R-41Min.1.5-inchmin.2.0pcfInsulfoamCR-20CR-20SBS-SA-H(Optional)SBS-TASBS-TA-240.0 roofRoofBoard Min. 1.5-inch Ultra-Max or Multi-Max FA-3, min. 1.3-inch Polytherm G,(Optional)additionallayers(s)ofbase Existing asphaltic R-42CR-20CR-20SBS-SA-H(Optional)SBS-TASBS-TA-240.0 ACFoamIIIormin.1.0-inchISO95+GL,insulation and/or min. 0.25-inch roof Polytherm H, H-Shield, H-Shield CG orSECUROCKGypsum-FiberRoofBoard ENRGY3 NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 81of83 N EMO|etc. TABLE7A:RECOVERAPPLICATIONS SYSTEMTYPEA-1:BONDEDINSULATION,BONDEDROOFCOVER BaseInsulationLayerTopInsulationLayerRoofCover(Note15) Substrate System*MDP AttachAttach No. (psf) (Notes1&12) TypeTypeBasePlyPlyCapPly (Notes6,7,8)(Notes6,7,8) (Optional)additionallayers(s)ofbase Existing asphalticMin. 2-inch Polytherm, ACFoam II, R-43CR-20insulation and/or min. 0.25-inchCR-20SBS-SA-H(Optional)SBS-TASBS-TA-247.5 roofENRGY-3,PolythermHorH-Shield SECUROCKGypsum-FiberRoofBoard C OLD A PPLIED B ASE P LY: (Optional) Min. 1-inch Polytherm,Min.0.25-inchDensDeckPrime,DEXcell Existing asphalticSBS-CA1,(Optional) SBS-CA1,SBS-CA1, SBS- ACFoam II, Polytherm G, ACFoam III,FA Glass Mat Roof Board or SECUROCK R-44D-ISD-IS-90.0 roofSBS-CA2SBS-CA2CA2,APP-CA1 ENRGY3,PolythermHorH-ShieldGypsum-FiberRoof Board (Optional) Min. 1-inch Polytherm,Min. 0.25-inch Dens Deck, Dens Deck ACFoam II, Polytherm G, ACFoam III,Prime, DEXcell FA Glass Mat Roof Board, EnergyGuard Polyiso Insulation, ENRGYSECUROCK Gypsum-Fiber Roof Board or Existing asphalticM-OSFA,M-OSFA orSBS-CA1,(Optional) SBS-CA1,SBS-CA1, SBS- R-453, Polytherm H, H-Shield ISO 95+ GL,SECUROCK Glass-Mat Roof Board, min.-120.0 roofM-PG1M-PG1SBS-CA2SBS-CA2CA2,APP-CA1 Multi-MaxFA3,RESISTAorUltraMaxor7/16-inchDEXcellCementRoofBoardor min. 2-inch DECKMATE Plus ormin. 0.5-inch SECUROCK Cement Roof DECKMATEPlusFABoard (Optional) Min. 1-inch Polytherm or ACFoam II, Polytherm G, ACFoam III,Min. 0.25-inch Dens Deck Prime or EnergyGuard Polyiso Insulation, ENRGYDEXcell FA Glass Mat Roof Board, min. Existing asphalticM-OSFA,M-OSFA, M-SBS-CA1, SBS- 7/16-inchDEXcellCementRoofBoardor R-463, PolythermH, H-Shield, ISO 95+ GL,SBS-CA1None-127.5 roofM-PG1PG1CA2,APP-CA1 Multi-MaxFA3,RESISTAorUltraMaxormin. 0.5-inch SECUROCK Cement Roof min. 2-inch DECKMATE Plus orBoard DECKMATEPlusFA (Optional) Min. 1-inch Polytherm or ACFoam II, Polytherm G, ACFoam III, EnergyGuard PolyisoInsulation, ENRGY Existing asphalticM-OSFA,Min.0.25-inchSECUROCKGypsum-FiberM-OSFA, M-SBS-CA1,SBS-CA1, SBS- R-473, Polytherm H, H-Shield, ISO 95+ GL,None-127.5 roofM-PG1RoofBoardPG1SBS-CA2CA2,APP-CA1 Multi-MaxFA3,RESISTAorUltraMaxor min. 2-inch DECKMATE Plus or DECKMATEPlusFA (Optional) Min. 1-inch Polytherm orMin. 0.25-inch Dens Deck, Dens Deck ACFoam II, Polytherm G, ACFoam III,Prime, DEXcell FA Glass Mat Roof Board, EnergyGuard Polyiso Insulation, ENRGYSECUROCK Gypsum-Fiber Roof Board or Existing asphalticM-OSFA,M-OSFA, M-SBS-CA1,SBS-CA1, SBS- R-483, Polytherm H, H-Shield, ISO 95+ GL,SECUROCK Glass-Mat Roof Board, min.None-157.5 roofM-PG1PG1SBS-CA2CA2 Multi-MaxFA3,RESISTAorUltraMaxor7/16-inchDEXcellCementRoofBoardor min. 2-inch DECKMATE Plus ormin. 0.5-inch SECUROCK Cement Roof DECKMATEPlusFABoard NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 82of83 N EMO|etc. TABLE7A:RECOVERAPPLICATIONS SYSTEMTYPEA-1:BONDEDINSULATION,BONDEDROOFCOVER BaseInsulationLayerTopInsulationLayerRoofCover(Note15) Substrate System*MDP AttachAttach No. (psf) (Notes1&12) TypeTypeBasePlyPlyCapPly (Notes6,7,8)(Notes6,7,8) (Optional) Min. 1-inch Polytherm, Min.0.25-inchDensDeckPrime,DEXcell Existing asphalticACFoamII, Polytherm G, ACFoam III,SBS-CA1,(Optional) SBS-CA1,SBS-CA1, SBS- FA Glass Mat Roof Board or SECUROCK R-49OB500OB500-120.0 roofENRGY 3, Polytherm H, H-Shield orSBS-CA2SBS-CA2CA2,APP-CA1 Gypsum-FiberRoof Board Multi-MaxFA3 (Optional) Min. 1-inch Polytherm, Existing asphalticACFoam II, Polytherm G, ACFoam III,Min.0.25-inchDensDeckPrimeorSBS-CA1, SBS- R-50OB500OB500SBS-CA1None-127.5 roofENRGY 3, Polytherm H, H-Shield orDEXcellFAGlassMatRoofBoardCA2,APP-CA1 Multi-MaxFA3 (Optional) Min. 1-inch Polytherm, Existing asphalticACFoam II, Polytherm G, ACFoam III,Min.0.25-inchSECUROCKGypsum-FiberSBS-CA1,SBS-CA1, SBS- R-51OB500OB500None-127.5 roofENRGY 3, Polytherm H, H-Shield orRoofBoardSBS-CA2CA2,APP-CA1 Multi-MaxFA3 (Optional) Min. 1-inch Polytherm, Existing asphalticACFoam II, Polytherm G, ACFoam III,Min. 0.25-inch Dens Deck Prime orSBS-CA1,(Optional) SBS-CA1,SBS-CA1, SBS- R-52CR-20CR-20-120.0 roofENRGY 3, Polytherm H, H-Shield orSECUROCKGypsum-FiberRoofBoardSBS-CA2SBS-CA2CA2,APP-CA1 Multi-MaxFA3 (Optional) Min. 1-inch Polytherm, Existing asphalticACFoam II, Polytherm G, ACFoam III,Min.0.25-inchDensDeckPrimeorSBS-CA1, SBS- R-53CR-20CR-20SBS-CA1None-127.5 roofENRGY 3, Polytherm H, H-Shield orDEXcellFAGlassMatRoofBoardCA2,APP-CA1 Multi-MaxFA3 (Optional) Min. 1-inch Polytherm, Existing asphalticACFoam II, Polytherm G, ACFoam III,Min.0.25-inchSECUROCKGypsum-FiberSBS-CA1,SBS-CA1, SBS- R-54CR-20CR-20None-127.5 roofENRGY 3, Polytherm H, H-Shield orRoofBoardSBS-CA2CA2,APP-CA1 Multi-MaxFA3 Existing asphaltic(Optional) Min. 1-inch ENRGY 3,Min. 0.25-inch Dens Deck Prime orSBS-CA1,SBS-CA1, SBS- R-55CR-20CR-20None-232.5 roofPolythermH,H-Shield,Multi-MaxFA3SECUROCKGypsum-FiberRoofBoardSBS-CA2CA2 TABLE7B:RECOVERAPPLICATIONS SYSTEMTYPEF:NON-INSULATED,BONDEDROOFCOVER RoofCover(Note15) Substrate SystemNo.PrimerMDP(psf) (Notes1&12) BasePlyPlyCapPly Existing fully-adhered, granule- R-56NonePolyflex,torch-applied(Optional)Polyflex,torch-appliedAPP-TA-362.5 surfacedmodifiedbitumen Existing fully-adhered, granule- R-57PG100Polyflex,torch-applied(Optional)Polyflex,torch-appliedAPP-TA-445.0 surfacedmodifiedbitumen NEMOETC,LLC EvaluationReportP40690.12.13-1-R11for FL16717-R10 TH CertificateofAuthorization#32455Revision11:10/01/2020 7EDITION(2020)FBCHVHZEVALUATION ©2018,NEMOETC,LLC PolyglassModifiedBitumenRoofSystems; (954)233-1330 Appendix1,Page 83of83 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 www.miamidade.gov/economy NOTICE OF ACCEPTANCE (NOA) Polyglass USA Inc. 1111 W. Newport Center Drive Deerfield Beach, FL 33442 S COPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER -Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOAshall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (in Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. D ESCRIPTION:Polyglass Polystick Underlayments L ABELING:Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. R ENEWALof this NOA shall be considered after a renewal application has been filed and there has been no change in theapplicable building code negatively affecting the performance of this product. T ERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. A DVERTISEMENT:The NOAnumber preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. I NSPECTION:A copy of this entire NOAshall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No.15-0410.04 and consists of pages 1 through 8. The submitted documentation was reviewed by Freddy Semino. NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 1of 8 R OOFING C OMPONENT A PPROVAL Roofing Category: Underlayment Sub-Category: SBS , APP Self-Adhering Modified Bitumen Material: P RODUCTS D ESCRIPTION: TestProduct ProductDimensionsSpecificationDescription 3 65'x 3'3-/"ASTM D 1970A fine granular/sand top surface self-adhering, APP Polystick IR-Xe 8 Or 65'x 3'polymer modified, fiberglass reinforced, bituminous Manufacturing 60 mils thicksheet material for useas an underlayment in sloped roof Location#1 & #2 assemblies. Designed as an ice & rain shield. 3 61'x 3'3-/"TAS 103 and A rubberized asphalt self-adhering, glass-fiber/polyester Polystick Dual Pro 8 60 mils thickASTM D 1970reinforced waterproofing membrane. Designed as a Manufacturing metal roofing and roof tile underlayment. Location#2 3 61'x 3'3-/"TAS 103 and A rubberized asphalt self-adhering, glass-fiber/polyester Polystick Tile Pro 8 60 mils thickASTM D 1970reinforced waterproofing membrane. Designed as a metal Manufacturing roofing and roof tile underlayment. Location#2 65'8"x 3'3-3/8"TAS 103 and A rubberized asphalt self-adhering, polyester reinforced Polystick TU Max 60 mils thickASTM D 1970waterproofing membrane. Designed as a a roof tile Manufacturing underlayment. Location#1 & #2 3 32'10"x 3'3-/"TAS 103 and A rubberized asphalt waterproofing membrane, glass- Polystick TU P 8 130 mils thickASTM D 1970fiber/polyester reinforced, with a granular surface Manufacturing designed for use as a tile roof underlayment. Location#2 3 65'x 3'3-/"TAS 103 and A rubberized asphalt self-adhering, glass-fiber/polyester Polystick TU Plus 8 (Surface Printing)80 mils thickASTM D 1970reinforced waterproofing membrane. Designed as a metal roofing and roof tile underlayment. Manufacturing Location#1 & #2 3 65'8"x 3'3-/"TAS 103A homogeneous, rubberized asphalt waterproofing Polystick MTS 8 60 mils thickmembrane, glass fiber reinforced with polyolefinic film Manufacturing on the upper surface for use as an underlayment for metal Location#2 roofing, roof tile, slate tiles and shingle underlayment. 3 65'8"x 3'3-/"TAS 103A homogeneous, rubberized asphalt waterproofing Polystick MTS Plus 8 60 mils thickmembrane, glass fiber reinforced with polyolefinic film Manufacturing on the upper surface for use as an underlayment for metal Location#2 roofing, roof tile, slate tiles and shingle underlayment. 32'10"x 3'3-"TAS 103 and Polyester reinforced, SBS modified bitumen membrane Elastoflex S6 G ASTM D 6164with a sanded back face and a granule top surface. For Manufacturing use in roof tile underlaymentsystems. Location#2 NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 2of 8 M ANUFACTURING P LANTS: 1. Hazelton, PA 2. Winter Haven, FL E VIDENCE S UBMITTED Test AgencyTest IdentifierTest Name/ReportDate Trinity | ERDP10870.09.08-R1TAS 10312/04/08 P10870.04.09TAS 103/ASTM D4798 & G15504/13/09 P33360.06.10ASTM D197007/01/10 P33370.03.11TAS 10303/02/11 P33370.04.11ASTM D 162304/26/11 P36900.09.11TAS 103/ASTM D4798 & G15509/01/11 P37300.10.11TAS 110/ASTM D4798 & D197010/19/11 P40390.08.12-2ASTM D 162308/07/12 P37590.07.13-1ASTM D616407/02/13 P45270.05.14TAS 103, TAS 110 & ASTM D162305/12/14 P46520.10.14ASTM D162310/03/14 P44360.10.14TAS 103 & TAS 11010/07/14 P43290.10.14ASTM D 1970 & TAS 11010/17/14 PLYG-SC10130.06.16-3TAS 103 & TAS 11006/27/16 PLYG-10130.06.16-1ASTM D1970 & TAS 11006/27/16 PRI Asphalt TechnologiesPUSA-035-02-01TAS 10309/29/06 PUSA-055-02-02TAS 10312/10/07 PUSA-089-02-01TAS 103/ASTM D4798 & G15507/06/09 Momentum Technologies, Inc.JX20H7ATAS 103/ASTM D4798 & G15504/01/08 RX14E8ATAS 103/ASTM D4798 & G15511/09/09 DX23D8BTAS 103/ASTM D4798 & G15502/18/10 DX23D8ATAS 103/ASTM D4798 & G15502/18/10 L ABELING: 1.All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facilityand the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. B UILDING P ERMIT R EQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 3of 8 I NSTALLATION P ROCEDURES: Wood, non-insulated Deck Type 1: Min. 19/32"plywood or wood plank Deck Description: Anchor sheet mechanically fastened to deck, membrane adhered System Type E(1): One or more plies of ASTM D 226 Type II or ASTM D 2626. Anchor/Base Sheet: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for Fastening: base sheet only) Membrane:Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS or Polystick MTS Plus,self-adhered. See General Limitations Below. Surfacing: Wood, non-insulated Deck Type 1: Min. 19/32"plywood or wood plank Deck Description: Anchor sheet mechanically fastened to deck, membrane adhered System Type E(2): One or more plies of ASTM D 226 Type II or ASTM D 2626. Anchor/Base Sheet: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for Fastening: base sheet only) Membrane:Elastoflex S6 G, hot asphalt applied See General Limitations Below. Surfacing: Wood, non-insulated Deck Type 1: Min. 19/32"plywood or wood plank Deck Description: System Type E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self-adhered. One or more plies of ASTM D 226 Type II or ASTM D 2626. Anchor/Base Sheet: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for Fastening: base sheet only) Ply Sheet:Polystick MTS Plus, self-adhered with minimum 3"horizontal laps and minimum 6" vertical laps. Membrane:Polystick TU Plus, self-adhered. See General Limitations Below. Surfacing: NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 4of 8 I NSTALLATION R EQUIREMENTS: All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose deck panels, and 1. sweep the deck thoroughly to remove any dust and debris prior to application. Place the underlayment over metal drip edge in accordance with RAS 111. 2. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. 3. Remove the release film as the membrane is applied. All sidand end laps shall be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. When applying the membrane in the valley, start at the low point and work to the high point, rolling the 4. membrane from the center outward in both directions. For ridge applications, center the membrane and roll from the center outward in both directions. 5. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention 6. to lap areas. Flash vent pipes, stacks, chimneys and penetrations in compliance with RoofAssembly current Product Control 7. Notice of Acceptance. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be 8. pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. G ENERAL L IMITATIONS: Fire classification is not part of this acceptance. 1. 2.Polystick Dual Pro, Polystick Tile Pro, Polystick TU Plus, Polystick MTSandPolystick MTS Plusmay be used in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, roof tile systems and quarry slate roof assemblies. Polystick TU Pmay be used in all the previous assemblies listed except metal roofing. Polystick IR-Xemay be used in all the previous assemblies listed except metal roofing and roof tile systems. Polystick TU Maxmay be used in non-structural metal roofing and roof tile systems. Elastoflex S6 Gmay be used in roof tile systems only. Deck requirements shall be in compliance with applicable building code. 3. 4.Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTSandPolystick MTS Plusshall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5.Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTSand Polystick MTS Plusshall not be adhered directly over a pre-existing roof membrane as a recover system. 6.Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTSand Polystick MTS Plusshall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. Exposure Limitations (Days) MTSIR-XeElastoflexTU TU PTile ProDual ProTU MaxMTS Plus S6 GPlus 18090180180180180180180180 Winter Haven, FL N/A90N/A180N/AN/AN/A180N/A Hazelton, PA All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and 7. NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 5of 8 Rule 61G20-3of theFlorida Administrative Code. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile 8. Polystick Tile Pro, Polystick TU Max, Polystick TU Plusor ElastoflexS6 Gmay be used in both adhesive set and mechanically fastened roof tile applications. Polystick Dual Prois limited to mechanically fastened roof tile applications. Polystick MTSand Polystick MTS Plusare limited to mechanically fastened with the limitations outlined in Section 9. Polystick TU Pmay be used in mechanically fastened roof tile applications with the exception of mortar set tile applications. When loading roof tilesonroof tile underlayment for (direct-to-deck) tile assemblies,the maximum roof slope 9. shall be as follows: (See Table Below) Tile Polystick Elastoflex Polystick TU Plus,Polystick Polystick System (E3) ProfileMTSS6 GTUP, Tile Pro, TU MaxMTS PlusMTS Plus with Dual ProTU Plus Flat TileProhibited 4:126:126:125:126:12 without battens Profiled Prohibited 4:126:126:124:126:12 Tilewithout battens The above slope limitations can be exceeded only by using battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements.When battens are required, they shall be utilized duringloading and installation of tiles. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of 10. tile directly on the underlayment.two tiles laid perpendicular to slope followed by a maximum four tile stack parallel to the slope, for a total of 6 tiles for all underlayments except Polystick MTSwhich shall be loaded onto battens. NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 6of 8 Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with 11. specific prepared roofing products. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 Gmay be used with any approved roof covering Notice of Acceptance listingPolystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plusor Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance. If Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plusor Elastoflex S6 Gare not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami-Dade County Product Control Sectionfor approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. P OLYGLASS G ENERAL A PPLICATION G UIDELINES FOR P OLYSTICK M EMBRANES P LEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. L OCAL CODES MAY SUPERSEDE P OLYGLASS REQUIREMENTS AND RECOMMENDATIONS. 1.Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codesprior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2.All rolls, with the exception of Polystick TU Plus should be back-nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1"metal disk as required in Miami-Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back-nailed. (Please refer to applicable local building codes prior to installation.) 3.All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. 4.All fabric over fabric; and granule over granule end laps, shall have a 6"wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium ModifiedWet/Dry Cement, Polyglass PG500 MB Flashing Cement, applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5.A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #9 and #10. 6.Battens and/or Counter-battens, as required by the tile manufacturers NOA, must be used on all projects for pitch/slopes of 7"/12"or greater. It is suggested that on pitch/slopes in excess of 6 ¼"/12", precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7.Minimum cure time after membrane installation & before loading of roofing tiles is Forty-Eight (48) Hours. 8.Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9.Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 7of 8 10.All self-adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11.All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12.The Polyglass Miami-Dade Notice of Acceptance (NOA) approval for Polystick membranes can be furnished upon request by our Technical Services Department by calling 1 (800) 894-4563. 13.Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800) 894-4563. 14.Polyglass recommends that applicatorsfollow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association (NRCA). P LEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. L OCAL CODES MAY SUPERSEDE P OLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 8of 8