Loading...
PERMIT DOCUMENTS N EMO|etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 E NGINEER E VALUATE T EST C ONSULT EVALUATION REPORT Tarco Roofing Evaluation Report T37910.06.11-R6 One Information Way, Suite 225 FL14672-R6 Little Rock, AR 72202 Date of Issuance: 06/23/2011 Revision 6: 08/04/2020 S COPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for th compliance with the 7 Edition (2020) Florida Building Code sections noted herein. D ESCRIPTION: LeakBarrier® Modified Bitumen Roof Systems L ABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. C ONTINUED C OMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. A DVERTISEMENT: The Florida Product Approval Number (FL#) displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. I NSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4, plus a 7-page Appendix. Prepared by: Robert J.M. Nieminen, P.E. The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 08/04/2020. This does not serve as an Florida Registration No. 59166, Florida DCA ANE1983 electronically signed document. C ERTIFICATION OF I NDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2019 NEMO ETC, LLC N EMO|etc. R OOFING S YSTEMS E VALUATION: 1. S COPE: Product Category: Roofing Sub-Category: Modified Bitumen Roof Systems Compliance Statement: LeakBarrier® Modified Bitumen Roof Systems, as produced by Tarco Roofing, have th demonstrated compliance with the following sections of the 7 Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. S TANDARDS: Section Property Standard Year 1504.3.1 Wind resistance FM 4474 2011 1504.6 Physical properties ASTM G155 2013 1504.7 Impact resistance FM 4470, Section 4.6 2016 1507.1.1 Material standard ASTM D1970 2015 1507.10.2 Material standard ASTM D226 2009 1507.10.2 Material standard ASTM D4601 2012 1507.11.2 Physical Properties ASTM D6163 2015 1507.11.2 Physical Properties ASTM D6164 2011 1507.11.2 Material standard ASTM D6222 2011 3. R EFERENCES: Entity Examination Reference Date ERD (TST6049) FM 4474 T36510.05.11 05/12/2011 ERD (TST6049) FM 4470 T39050.11.11 11/18/2011 ERD (TST6049) Criticality T39040.11.11 11/21/2011 ERD (TST6049) ASTM D6222 (TX) T35450.12.11 12/21/2011 ERD (TST6049) FM 4474 K39690SC 03/07/2012 ERD (TST6049) FM 4470, Section 4.6 T40800.02.12 02/22/2012 ERD (TST6049) ASTM D6222 (TX) T43940.05.13 05/01/2013 ERD (TST6049) ASTM D4601 (TX) T43410.05.13 05/23/2013 ERD (TST6049) FM 4474 TAR-SC7960.01.16 01/31/2016 ERD (TST6049) FM 4474 TAR-SC5670.03.16 03/21/2016 ERD (TST6049) ASTM D226 (TX) TAR-SC13965.02.17-R1 02/27/2017 ERD (TST6049) FM 4474 T6460.06.07-R2 05/26/2017 ERD (TST6049) ASTM D6163 (TX) T6470.08.07-R2 06/02/2017 ERD (TST6049) ASTM D4601 (TX) TAR-SC16545.11.17 11/01/2017 NEMO (TST6049) ASTM D6164 (TX) 4-TAR-18-002.04.18 04/16/2018 NEMO (TST6049) Criticality 4i-TAR-2-SSCRT-01.A 07/17/2020 PRI (TST5878) ASTM D1970 (TX) BRY-018-02-01 08/11/2003 Tarco Roofing FBC Cross-List Listing Agreement 01/20/2020 UL (QUA1743) Quality Assurance Service Confirmation 04/07/2020 NEMO ETC, LLC Evaluation Report T37910.06.11-R6 TH Certificate of Authorization #32455 7EDITION (2020) FBC NON-HVHZ EVALUATION FL14672-R6 LeakBarrier® Modified Bitumen Roof Systems Revision 6: 08/04/2020 Page 2 of 4 N EMO|etc. 4. P RODUCT D ESCRIPTION: This Evaluation Report covers LeakBarrier® Modified Bitumen Roof Systems installed in accordance with Tarco Roofing published installation instructions and the Limitations / Conditions of Use herein. The following products make up the subject systems. T ABLE 1: R OLL-G OODS FOR L EAK B ARRIER® M ODIFIED B ITUMEN R OOF S YSTEMS Material Standard Type Product Plant(s) Reference Type Grade LeakBarrier® EasyLay ASTM D226 II N/A TX Base Sheets ASTM D4601 II N/A TX LeakBarrier® MS300 ASTM D1970 N/A N/A TX TopShield Ice & Water G300 ASTM D1970 N/A N/A TX Smooth Surfaced LeakBarrier® EasyBase ASTM D4601 II N/A TX Membranes: LeakBarrier® EasyTorch SA Base ASTM D4601 II N/A TX LeakBarrier® EasyTorch APP Smooth ASTM D6222 I S TX LeakBarrier® EasyStick Plus ASTM D6164 I G TX Granule Surfaced Membranes: LeakBarrier® EasyTorch APP Granular ASTM D6222 I G TX 5. L IMITATIONS: 5.1 This is a Building Code Evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami- Dade Counties). This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in 5.3 accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 This Evaluation Report does not include evaluation of roof edge termination. Refer to FBC 1504.5 for requirements and limitations regarding edge securement for low-slope roofs. 5.6 Refer to FBC 1511 for requirements and limitations regarding recover installations. For mechanically attached components over existing roof decks, fasteners shall be tested in the existing deck for 5.6.1 withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 5.6.2 For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.6.3 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 5.7 Refer to Appendix 1 for system attachment requirements for wind load resistance. NEMO ETC, LLC Evaluation Report T37910.06.11-R6 TH Certificate of Authorization #32455 7EDITION (2020) FBC NON-HVHZ EVALUATION FL14672-R6 LeakBarrier® Modified Bitumen Roof Systems Revision 6: 08/04/2020 Page 3 of 4 N EMO|etc. 5.7.1 and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. 5.7.2 For mechanically attached components or partially-bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for Zone 2/3 enhancements. 5.7.3 For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 5.8 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. Refer to the Product Approval of the component manufacturer for components listed in Appendix 1 that are produced by a Product Manufacturer other than the report holder on Page 1 of this Evaluation Report. 6. I NSTALLATION: LeakBarrier® Modified Bitumen Roof Systems shall be installed in accordance with Tarco Roofing published installation instructions, subject to the Limitations / Conditions of Use noted herein. 7. B UILDING P ERMIT R EQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. 8. M ANUFACTURING P LANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. 9. Q UALITY A SSURANCE E NTITY: Underwriters Laboratories QUA1743; (414) 248-6409; Karen.buchmann@us.ul.com - THE SEVEN (7) PAGES THAT FOLLOWS FORM PART OF THIS EVALUATION REPORT - NEMO ETC, LLC Evaluation Report T37910.06.11-R6 TH Certificate of Authorization #32455 7EDITION (2020) FBC NON-HVHZ EVALUATION FL14672-R6 LeakBarrier® Modified Bitumen Roof Systems Revision 6: 08/04/2020 Page 4 of 4 N EMO|etc. A PPENDIX 1: A TTACHMENT R EQUIREMENTS FOR W IND U PLIFT R ESISTANCE TABLE DECK APPLICATION TYPE DESCRIPTION PAGE 1A WoodNew, Reroof (Tear-Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 2 1B WoodNew, Reroof (Tear-Off) or Recover D Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 3 1C WoodNew or Reroof (Tear-Off) E Non-Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover 4-5 1D WoodNew, Reroof (Tear-Off) or Recover E Non-Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover 6 1E WoodNew or Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 7 2A Structural concrete New or Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 7 The following notes apply to the systems outlined herein: 1The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 2Unless otherwise noted, fasteners and stress plates shall be as follows. Fasteners shall be of sufficient length for the following engagements: Wood: OMG #12 or #14 HD with OMG 3 in. Galvalume Steel Plate (non-ribbed) or Trufast #12 DP or #14 HD with Plates. Minimum ¾-inch plywood penetration or minimum 1- inch wood plank embedment. 3Unless otherwise noted, insulation may be any one layer or combination of FBC Approved (Local or Statewide) board(s) that meet FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. 4Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (February 2020). 5For mechanically attached components or partially-bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for Zone 2/3 enhancements. 6For assemblies with all components fully bonded, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 7For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 8For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance shall be conducted on mock-ups of the proposed new roof assembly. For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing. Field uplift testing shall be in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 9Refer to FBC 1511 for requirements and limitations regarding recover installations. For Recover Applications using System Type C-1, C-2, D-1 or D-2, the insulation is optional. Alternatively, an FBC Approved insulation board or coverboard may be used as a separation layer. Board products shall be preliminarily attached prior to roof cover installation. The separator component shall be documented as meeting FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover in Recover applications. 10 wind loads. Refer to FBC 1609 for determination of design wind loads. NEMO ETC, LLC Evaluation Report T37910.06.11-R6 for FL14672-R6 TH Certificate of Authorization #32455 7 EDITION (2020) FBC NON-HVHZ EVALUATION Revision 6: 08/04/2020 ©2019 NEMO ETC, LLC LeakBarrier® Modified Bitumen Roof Systems; (254) 913-7750 Appendix 1, Page 1 of 7 N EMO|etc. TABLE 1A: WOOD DECKS NEW CONSTRUCTION, REROOF (Tear-Off) or RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER Top Insulation Layer Roof Cover Deck System MDP Base Insulation Layer No. (psf) (Note1) Type Fasteners Attach Base Ply Ply Cap S ELF-A DHERING B ASE P LY: Min. 15(Optional) One or more Min. 3/8-inch SECUROCK Gypsum-1 per EasyBase, self-(Optional) EasyBase, self-EasyStick Plus, self- W-1. plywood at max. layers, any combination, Note 2 -52.5 2 Fiber Roof Board 1.0 ft adhering adhering adhering loose laid Min. 15(Optional) One or more EasyTorch SA (Optional) EasyTorch SA Base, EasyTorch APP Smooth Min. 3/8-inch SECUROCK Gypsum-1 per W-2. plywood at max. layers, any combination, Note 2 Base, self-self-adhering or EasyTorch APP or Granular, torch--52.5 2 Fiber Roof Board 1.0 ft spans loose laid adhering Smooth, torch-applied applied LeakBarrier Min. 15(Optional) One or more EasyTorch APP Smooth MS300 or Min. 3/8-inch SECUROCK Gypsum-1 per (Optional) EasyTorch APP W-3. plywood at max. layers, any combination, Note 2 TopShield Ice & or Granular, torch--52.5 2 Fiber Roof Board 1.0 ft Smooth, torch-applied spans loose laid Water G300, self-applied adhering Min. 15(Optional) One or more Min. 2-inch ACFoam II, EnergyGuard 1 per EasyBase, self-(Optional) EasyBase, self-EasyStick Plus, self- plywood at max. layers, any combination, Polyiso, ENRGY 3, H-Shield, ISO 95+ W-4. Note 2 -82.5 2 1.0 ft adhering adhering adhering loose laid GL or Multi-Max FA3 Min. 15(Optional) One or more Min. 2-inch ACFoam II, EnergyGuard EasyTorch SA (Optional) EasyTorch SA Base, EasyTorch APP Smooth 1 per W-5. plywood at max. layers, any combination, Polyiso, ENRGY 3, H-Shield, ISO 95+ Note 2 Base, self-self-adhering or EasyTorch APP or Granular, torch--82.5 2 1.0 ft loose laid GL or Multi-Max FA3 adhering Smooth, torch-applied applied LeakBarrier Min. 15(Optional) One or more Min. 2-inch ACFoam II, EnergyGuard MS300 or EasyTorch APP Smooth 1 per (Optional) EasyTorch APP W-6. plywood at max. layers, any combination, Polyiso, ENRGY 3, H-Shield, ISO 95+ Note 2 TopShield Ice & or Granular, torch--82.5 2 1.0 ft Smooth, torch-applied loose laid GL or Multi-Max FA3 Water G300, self-applied adhering T ORCH-A PPLIED B ASE P LY: Min. 15(Optional) One or more EasyTorch APP EasyTorch APP Smooth Min. 3/8-inch SECUROCK Gypsum-1 per (Optional) EasyTorch APP W-7. plywood at max. layers, any combination, Note 2 Smooth, torch-or Granular, torch--52.5 2 Fiber Roof Board 1.0 ft Smooth, torch-applied loose laid applied applied NEMO ETC, LLC Evaluation Report T37910.06.11-R6 for FL14672-R6 TH Certificate of Authorization #32455 7 EDITION (2020) FBC NON-HVHZ EVALUATION Revision 6: 08/04/2020 ©2019 NEMO ETC, LLC LeakBarrier® Modified Bitumen Roof Systems; (254) 913-7750 Appendix 1, Page 2 of 7 N EMO|etc. TABLE 1B: WOOD DECKS NEW CONSTRUCTION, REROOF (Tear-Off) or RECOVER SYSTEM TYPE D: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER Insulation LayerBase SheetRoof Cover Deck System MDP No.(psf) (Note1) TypeAttachTypeFastenersAttachBase PlyPlyCap Ply S ELF-A DHERING B ASE P LY: Min. 15Any type, 10-inch o.c. in the min. 4-inch lap and Loose EasyBase, self-(Optional) EasyBase, self-EasyStick Plus, self- W-8.plywood at max. thickness or EasyLayNote210-inch o.c. in two(2), equally -60.0 laidadheringadheringadhering combinationspaced, staggered center rows Min. 15Any type, 10-inch o.c. in the min. 4-inch lap and EasyTorch SA (Optional) EasyTorch SA Base, EasyTorch APP Loose W-9.plywood at max. thickness or EasyLayNote210-inch o.c. in two(2), equally Base, self-self-adheringor EasyTorch Smooth or Granular, -60.0 laid combinationspaced, staggered center rowsadheringAPP Smooth, torch-appliedtorch-applied LeakBarrier Min. 15Any type, 10-inch o.c. in the min. 4-inch lap and EasyTorch APP MS300 or Loose (Optional) EasyTorch APP W-10.plywood at max. thickness or EasyLayNote210-inch o.c. in two(2), equally TopShield Ice & Smooth or Granular, -60.0 laidSmooth, torch-applied combinationspaced, staggered center rowsWater G300, torch-applied self-adhering Min. 15Any type, 8-inch o.c. in the min. 4-inch lap and Loose EasyBase, self-(Optional) EasyBase, self-EasyStick Plus, self- plywood at max. thickness or 8-inch o.c. in four (4), equally spaced, W-11.EasyLayNote2-135.0 laidadheringadheringadhering combinationstaggered center rows Min. 15Any type, 8-inch o.c. in the min. 4-inch lap and EasyTorch SA (Optional) EasyTorch SA Base, EasyTorch APP Loose W-12.plywood at max. thickness or EasyLayNote28-inch o.c. in four (4), equally spaced, Base, self-self-adheringor EasyTorch Smooth or Granular, -135.0 laid combinationstaggered center rowsadheringAPP Smooth, torch-appliedtorch-applied LeakBarrier Min. 15Any type, 8-inch o.c. in the min. 4-inch lap and MS300 or EasyTorchAPP Loose (Optional) EasyTorch APP W-13.plywood at max. thickness or EasyLayNote28-inch o.c. in four (4), equally spaced, TopShield Ice & Smooth or Granular, -135.0 laidSmooth, torch-applied combinationstaggered center rowsWater G300, torch-applied self-adhering Min. 1Min. 155Any type, Any type, 66--inch o.c. in the min. 4inch o.c. in the min. 4--inch lap and inch lap and Loose Loose EasyBase, selfEasyBase, self--(Optional) (Optional) EasyBase, selfEasyBase, self--EasyStick Plus, selfEasyStick Plus, self-- WW--14.14.plywood at max. plywood at max. thickness or thickness or EasyNailBaseEasyNailBaseNoteNote2266--inch o.c. in inch o.c. in four (4)four (4), equally spaced, , equally spaced, --135135.0.0 laidlaidadheringadheringadheringadheringadheringadhering combinationcombinationstaggered center staggered center rowsrows Min. 15Any type, 6-inch o.c. in the min. 4-inch lap and EasyTorch SA (Optional) EasyTorch SA Base, EasyTorch APP Loose W-15.plywood at max. thickness or EasyNailBaseNote26-inch o.c. in four (4), equally spaced, Base, self-self-adheringor EasyTorch Smooth or Granular, -135.0 laid combinationstaggered center rowsadheringAPP Smooth, torch-appliedtorch-applied LeakBarrier Min. 15Any type, 6-inch o.c. in the min. 4-inch lap and MS300 or EasyTorch APP Loose (Optional) EasyTorch APP W-16.plywood at max. thickness or EasyNailBaseNote26-inch o.c. in four (4), equally spaced, TopShield Ice & Smooth or Granular, -135.0 laidSmooth, torch-applied combinationstaggered center rowsWater G300, torch-applied self-adhering T ORCH-A PPLIED B ASE P LY: Min. 15Any type, 6-inch o.c. in the min. 4-inch lap and EasyTorch APP EasyTorch APP Loose (Optional) EasyTorchAPP W-17.plywood at max. thickness or EasyNailBaseNote26-inch o.c. in four (4), equally spaced, Smooth, torch-Smooth or Granular, -135.0 laidSmooth, torch-applied combinationstaggered center rowsappliedtorch-applied NEMO ETC, LLC Evaluation Report T37910.06.11-R6for FL14672-R6 TH Certificate of Authorization #32455 7EDITION (2020) FBC NON-HVHZ EVALUATION Revision 6: 08/04/2020 ©2019 NEMO ETC, LLC LeakBarrier®Modified Bitumen Roof Systems; (254) 913-7750 Appendix 1, Page 3of 7 N EMO|etc. TABLE 1C: WOOD DECKS NEW CONSTRUCTION or REROOF (Tear-Off) SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (nails), BONDED ROOF COVER Base Sheet Roof Cover Deck System MDP No. (psf) (Note 1) Type Fasteners Attach Base Ply Ply Cap Ply S ELF-A DHERING B ASE P LY: 12 ga. annular ring shank nails 7-inch o.c. in the 4-inch lap and 7- (Optional) EasyBase, self-EasyStick Plus, self- and min. 32 ga., 1- W-18. plywood at max. EasyLay inch o.c. in three (3), equally EasyBase, self-adhering -60.0 diameter tin-caps. (Ref: FBC adhering adhering spaced, staggered center rows 1517.5) 12 ga. annular ring shank nails Min. 197-inch o.c. in the 4-inch lap and 7-(Optional) EasyTorch SA Base, EasyTorch APP and min. 32 ga., 1-EasyTorch SA Base, W-19. plywood at max. EasyLay inch o.c. in three (3), equally self-adhering or EasyTorch Smooth or Granular, -60.0 diameter tin-caps. (Ref: FBC self-adhering spaced, staggered center rows APP Smooth, torch-applied torch-applied 1517.5) 12 ga. annular ring shank nails Min. 197-inch o.c. in the 4-inch lap and 7-LeakBarrier MS300 or EasyTorch APP and min. 32 ga., 1-(Optional) EasyTorch APP W-20. plywood at max. EasyLay inch o.c. in three (3), equally TopShield Ice & Water Smooth or Granular, -60.0 diameter tin-caps. (Ref: FBC Smooth, torch-applied spaced, staggered center rows G300, self-adhering torch-applied 1517.5) Min. 158-inch o.c. in the min. 4-inch lap and (Optional) EasyBase, self-EasyStick Plus, self- W-21. plywood at max. EasyLay Simplex MAXX Cap Fastener 8-inch o.c. in four (4), equally EasyBase, self-adhering -82.5 adhering adhering spaced, staggered center rows Min. 158-inch o.c. in the min. 4-inch lap and (Optional) EasyTorch SA Base, EasyTorch APP EasyTorch SA Base, W-22. plywood at max. EasyLay Simplex MAXX Cap Fastener 8-inch o.c. in four (4), equally self-adhering or EasyTorch Smooth or Granular, -82.5 self-adhering spaced, staggered center rows APP Smooth, torch-applied torch-applied Min. 158-inch o.c. in the min. 4-inch lap and LeakBarrier MS300 or EasyTorch APP (Optional) EasyTorch APP W-23. plywood at max. EasyLay Simplex MAXX Cap Fastener 8-inch o.c. in four (4), equally TopShield Ice & Water Smooth or Granular, -82.5 Smooth, torch-applied spaced, staggered center rows G300, self-adhering torch-applied 12 ga. annular ring shank nails Min. 154-inch o.c. in the 4-inch lap and 4- (Optional) EasyBase, self-EasyStick Plus, self- and min. 32 ga., 1- W-24. plywood at max. EasyLay inch o.c. in four (4), equally spaced, EasyBase, self-adhering -120.0 diameter tin-caps. (Ref: FBC adhering adhering staggered center rows 1517.5) 12 ga. annular ring shank nails Min. 154-inch o.c. in the 4-inch lap and 4-(Optional) EasyTorch SA Base, EasyTorch APP and min. 32 ga., 1-EasyTorch SA Base, W-25. plywood at max. EasyLay inch o.c. in four (4), equally spaced, self-adhering or EasyTorch Smooth or Granular, -120.0 diameter tin-caps. (Ref: FBC self-adhering staggered center rows APP Smooth, torch-applied torch-applied 1517.5) 12 ga. annular ring shank nails Min. 154-inch o.c. in the 4-inch lap and 4-LeakBarrier MS300 or EasyTorch APP and min. 32 ga., 1-(Optional) EasyTorch APP W-26. plywood at max. EasyLay inch o.c. in four (4), equally spaced, TopShield Ice & Water Smooth or Granular, -120.0 diameter tin-caps. (Ref: FBC Smooth, torch-applied staggered center rows G300, self-adhering torch-applied 1517.5) 12 ga. annular ring shank nails Min. 154-inch o.c. in the 4-inch lap and 4- and min. 32 ga., 1-(Optional) EasyBase, self-EasyStick Plus, self- plywood at max. inch o.c. in five (5), equally spaced, W-27. EasyNailBase EasyBase, self-adhering -120.0 diameter tin-caps. (Ref: FBC adhering adhering staggered center rows 1517.5) NEMO ETC, LLC Evaluation Report T37910.06.11-R6 for FL14672-R6 TH Certificate of Authorization #32455 7 EDITION (2020) FBC NON-HVHZ EVALUATION Revision 6: 08/04/2020 ©2019 NEMO ETC, LLC LeakBarrier® Modified Bitumen Roof Systems; (254) 913-7750 Appendix 1, Page 4 of 7 N EMO|etc. TABLE 1C: WOOD DECKS NEW CONSTRUCTION or REROOF (Tear-Off) SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (nails), BONDED ROOF COVER Base Sheet Roof Cover Deck System MDP No. (psf) (Note 1) Type Fasteners Attach Base Ply Ply Cap Ply 12 ga. annular ring shank nails Min. 154-inch o.c. in the 4-inch lap and 4-(Optional) EasyTorch SA Base, EasyTorch APP and min. 32 ga., 1-EasyTorch SA Base, W-28. plywood at max. EasyNailBase inch o.c. in five (5), equally spaced, self-adhering or EasyTorch Smooth or Granular, -120.0 diameter tin-caps. (Ref: FBC self-adhering staggered center rows APP Smooth, torch-applied torch-applied 1517.5) 12 ga. annular ring shank nails Min. 154-inch o.c. in the 4-inch lap and 4-LeakBarrier MS300 or EasyTorch APP (Optional) EasyTorch APP and min. 32 ga., 1- W-29. plywood at max. EasyNailBase inch o.c. in five (5), equally spaced, TopShield Ice & Water Smooth or Granular, -120.0 diameter tin-caps. (Ref: FBC Smooth, torch-applied staggered center rows G300, self-adhering torch-applied 1517.5) T ORCH-A PPLIED B ASE P LY: Min. 159-inch o.c. in the min. 2-inch lap and (Optional) EasyTorch EasyTorch APP (Optional) EasyTorch APP W-30. plywood at max. EasyNailBase Simplex MAXX Cap Fastener 18-inch o.c. in two (2), equally APP Smooth, torch-Smooth or Granular, -45.0* Smooth, torch-applied spaced, staggered center rows applied torch-applied Min. 159-inch o.c. in the min. 2-inch lap and (Optional) EasyTorch EasyTorch APP (Optional) EasyTorch APP plywood at max. 12-inch o.c. in two (2), equally APP Smooth, torch-Smooth or Granular, W-31. EasyNailBase Simplex MAXX Cap Fastener -52.5 Smooth, torch-applied spaced, staggered center rows applied torch-applied Min. 156-inch o.c. in the min. 2-inch lap and (Optional) EasyTorch EasyTorch APP (Optional) EasyTorch APP W-32. plywood at max. EasyNailBase Simplex MAXX Cap Fastener 6-inch o.c. in two (2), equally APP Smooth, torch-Smooth or Granular, -90.0 Smooth, torch-applied spaced, staggered center rows applied torch-applied Min. 156-inch o.c. in the min. 2-inch lap and (Optional) EasyTorch EasyTorch APP (Optional) EasyTorch APP W-33. plywood at max. EasyNailBase Simplex MAXX Cap Fastener 6-inch o.c. in three (3), equally APP Smooth, torch-Smooth or Granular, -105.0 Smooth, torch-applied spaced, staggered center rows applied torch-applied 12 ga. annular ring shank nails Min. 154-inch o.c. in the 4-inch lap and 4-(Optional) EasyTorch EasyTorch APP and min. 32 ga., 1-(Optional) EasyTorch APP W-34. plywood at max. EasyNailBase inch o.c. in five (5), equally spaced, APP Smooth, torch-Smooth or Granular, -120.0 diameter tin-caps. (Ref: FBC Smooth, torch-applied staggered center rows applied torch-applied 1517.5) NEMO ETC, LLC Evaluation Report T37910.06.11-R6 for FL14672-R6 TH Certificate of Authorization #32455 7 EDITION (2020) FBC NON-HVHZ EVALUATION Revision 6: 08/04/2020 ©2019 NEMO ETC, LLC LeakBarrier® Modified Bitumen Roof Systems; (254) 913-7750 Appendix 1, Page 5 of 7 N EMO|etc. TABLE 1D: WOOD DECKS NEW CONSTRUCTION, REROOF (Tear-Off) or RECOVER SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (screws & plates), BONDED ROOF COVER Base Sheet Roof Cover Deck System MDP No. (psf) (Note 1) Type Fasteners Attach Base Ply Ply Cap Ply S ELF-A DHERING B ASE P LY: Min. 15 10-inch o.c. in the min. 4-inch lap and 10-inch o.c. (Optional) EasyBase, self-EasyStick Plus, self- W-35. plywood at max. EasyLay Note 2 EasyBase, self-adhering -60.0 in two (2), equally spaced, staggered center rows adhering adhering Min. 15(Optional) EasyTorch SA Base, EasyTorch APP 10-inch o.c. in the min. 4-inch lap and 10-inch o.c. EasyTorch SA Base, self- W-36. plywood at max. EasyLay Note 2 self-adhering or EasyTorch APP Smooth or Granular, -60.0 in two (2), equally spaced, staggered center rows adhering Smooth, torch-applied torch-applied Min. 15LeakBarrier MS300 or EasyTorch APP 10-inch o.c. in the min. 4-inch lap and 10-inch o.c. (Optional) EasyTorch APP W-37. plywood at max. EasyLay Note 2 TopShield Ice & Water Smooth or Granular, -60.0 in two (2), equally spaced, staggered center rows Smooth, torch-applied G300, self-adhering torch-applied Min. 15 8-inch o.c. in the min. 4-inch lap and 8-inch o.c. in (Optional) EasyBase, self-EasyStick Plus, self- W-38. plywood at max. EasyLay Note 2 EasyBase, self-adhering -135.0 four (4), equally spaced, staggered center rows adhering adhering Min. 15(Optional) EasyTorch SA Base, EasyTorch APP 8-inch o.c. in the min. 4-inch lap and 8-inch o.c. in EasyTorch SA Base, self- plywood at max. self-adhering or EasyTorch APP Smooth or Granular, W-39. EasyLay Note 2 -135.0 four (4), equally spaced, staggered center rows adhering Smooth, torch-applied torch-applied Min. 15LeakBarrier MS300 or EasyTorch APP 8-inch o.c. in the min. 4-inch lap and 8-inch o.c. in (Optional) EasyTorch APP W-40. plywood at max. EasyLay Note 2 TopShield Ice & Water Smooth or Granular, -135.0 four (4), equally spaced, staggered center rows Smooth, torch-applied G300, self-adhering torch-applied Min. 15 6-inch o.c. in the min. 4-inch lap and 6-inch o.c. in (Optional) EasyBase, self-EasyStick Plus, self- plywood at max. W-41. EasyNailBase Note 2 EasyBase, self-adhering -135.0 four (4), equally spaced, staggered center rows adhering adhering Min. 15(Optional) EasyTorch SA Base, EasyTorch APP 6-inch o.c. in the min. 4-inch lap and 6-inch o.c. in EasyTorch SA Base, self- W-42. plywood at max. EasyNailBase Note 2 self-adhering or EasyTorch APP Smooth or Granular, -135.0 four (4), equally spaced, staggered center rows adhering Smooth, torch-applied torch-applied Min. 15LeakBarrier MS300 or EasyTorch APP 6-inch o.c. in the min. 4-inch lap and 6-inch o.c. in (Optional) EasyTorch APP plywood at max. TopShield Ice & Water Smooth or Granular, W-43. EasyNailBase Note 2 -135.0 four (4), equally spaced, staggered center rows Smooth, torch-applied G300, self-adhering torch-applied T ORCH-A PPLIED B ASE P LY: Min. 15EasyTorch APP 6-inch o.c. in the min. 4-inch lap and 6-inch o.c. in (Optional) EasyTorch APP (Optional) EasyTorch APP W-44. plywood at max. EasyNailBase Note 2 Smooth or Granular, -135.0 four (4), equally spaced, staggered center rows Smooth, torch-applied Smooth, torch-applied torch-applied NEMO ETC, LLC Evaluation Report T37910.06.11-R6 for FL14672-R6 TH Certificate of Authorization #32455 7 EDITION (2020) FBC NON-HVHZ EVALUATION Revision 6: 08/04/2020 ©2019 NEMO ETC, LLC LeakBarrier® Modified Bitumen Roof Systems; (254) 913-7750 Appendix 1, Page 6 of 7 N EMO|etc. TABLE 1E: WOOD DECKS NEW CONSTRUCTION or REROOF (Tear-Off) SYSTEM TYPE F: BONDED ROOF COVER Deck (Note 1) Roof Cover System MDP No. (psf) Type Joint Treatment Base Ply Ply Cap Min. 15EasyStick Plus, self- W-45. None (Optional) EasyBase, self-adhering (Optional) EasyBase, self-adhering -75.0 adhering (Optional) EasyTorch SA Base, self-adhering EasyTorch APP Smooth or W-46. None EasyTorch SA Base, self-adhering -75.0 or EasyTorch APP Smooth, torch-applied Granular, torch-applied LeakBarrier MS300 or TopShield Ice (Optional) EasyTorch APP Smooth, torch-EasyTorch APP Smooth or W-47. None -75.0 & Water G300, self-adhering applied Granular, torch-applied Plywood joints are covered with 4-inch wide strips of Min. 15EasyStick Plus, self- EasyBase, self-adhering, rolled into place to create W-48. (Optional) EasyBase, self-adhering (Optional) EasyBase, self-adhering -120.0 adhering continuous bond. Plywood joints are covered with 4-inch wide strips of Min. 15(Optional) EasyTorch SA Base, self-adhering EasyTorch APP Smooth or EasyBase, self-adhering, rolled into place to create W-49. EasyTorch SA Base, self-adhering -120.0 or EasyTorch APP Smooth, torch-applied Granular, torch-applied continuous bond. Plywood joints are covered with 4-inch wide strips of Min. 15LeakBarrier MS300 or TopShield Ice (Optional) EasyTorch APP Smooth, torch-EasyTorch APP Smooth or EasyBase, self-adhering, rolled into place to create W-50. -120.0 & Water G300, self-adhering applied Granular, torch-applied continuous bond. TABLE 2A: CONCRETE DECKS - NEW CONSTRUCTION or REROOF (Tear-Off) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER Roof Cover Deck System MDP Primer No.(psf) (Note 1) Base Ply Ply Cap C-1. Concrete ASTM D41 EasyTorch APP Smooth, torch-applied (Optional) EasyTorch APP Smooth, torch-applied EasyTorch APP Smooth or Granular, torch-applied -670.0 NEMO ETC, LLC Evaluation Report T37910.06.11-R6 for FL14672-R6 TH Certificate of Authorization #32455 7 EDITION (2020) FBC NON-HVHZ EVALUATION Revision 6: 08/04/2020 ©2019 NEMO ETC, LLC LeakBarrier® Modified Bitumen Roof Systems; (254) 913-7750 Appendix 1, Page 7 of 7