PERMIT DOCUMENTS FBC SECTION 1524 HIGH-VELOCITY HURRICANE ZONES REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section. The provisions of Chapter 15 of the CƌƚƩźķğ .ǒźƌķźƓŭ /ƚķĻͲ .ǒźƌķźƓŭ govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the s in the designated space indicates that the item has been explained. _______ Aesthetics-workmanship. Reserved. _______ Renailing wood decks. When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Chapter 16 (High-Velocity Hurricane Zones) of the CƌƚƩźķğ .ǒźƌķźƓŭ/ƚķĻͲ .ǒźƌķźƓŭ. (The roof deck is usually concealed prior to removing the existing roof system.) _______ Common Roofs. Reserved. _______ Exposed ceilings. Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The ownermay wish to maintain the architectural appearance; therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The owner provides the option of maintaining this appearance. _______ Ponding Water. Reserved. _______ Overflow Scuppers (wall outlets). It is required that rainwater flow off so that the roof is not overloaded from a buildup of water. Perimeter/edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of: Chapters 15 and 16 herein and the CƌƚƩźķğ .ǒźƌķźƓŭ /ƚķĻͲ tƌǒƒĬźƓŭ. _______ Ventilation. Reserved. 9/14/21 ____________________________________________________________________ Owners/AgentsSignature Date Contractors Signature Flat Roof Replacement NOA 19-0311.04 pg. 30 SLOPE under .125/12 Engineered calcs attached Shingle Roof Replacement #30 Felt @ 50% laps (2 layers) SLOPE 3/12 NOA 20-0723.14 VM!Dmbtt!B!Mjtujoh gps!Tfmg.Beifsfe!Bttfncmjft VM!Qspevdu!Tqfd«!.!UHGV/S25682! 5:/!Efdl;!D.26043 Jodmjof;!3 Jotvmbujpo!)Pqujpobm*;!.!Qpmzjtpdzbovsbuf-!qfsmjuf-!xppe!"cfs!ps! qpmzjtpdzbovsbuf0qfsmjuf!cpbse-!boz!uijdloftt/ Cbtf!Tiffu;!.!#FMBTUPCBTF#-!nfdibojdbmmz!gbtufofe!ps!! #FMBTUPGMFY!TB!W!GS#-!tfmg.beifsfe/ Qmz!Tiffu!)Pqujpobm*;!.!#FMBTUPGMFY!TB!W!QMVT!GS#-!#FMBTUPGMFY! TB!W!GS#!ps!#FMBTUPGMFY!TB!W!GS!CBTF!WFOU#-!tfmg.beifsfe/ Nfncsbof;!.!#QPMZGMFY!TB!Q!GS#-!#QPMZGSFTLP!H!BQQ!TB!Q!GS#-!! #FMBTUPGMFY!TB!Q!GS#-!#QPMZGSFTLP!H!TCT!TB!Q!GS#-!tfmg.beifsfe! ps!#EVGMFY!H!GS#-!#YusbGmfy!BQQ!Evbm#-!#QPMZGMFY!H!GS#-!#YusbGmfy! BQQ!H!IQ#-!#Yusb#fy!BQQ!H!GS#-!#FMBTUPGMFY!T7!H!GS#-!!!!! #QPMZGSFTLP!H!TCT!GS#-!#FMBTUPGMFY!WH!GS#-!#YusbGmfy!TCT!QPMZ!!! H#-!#YusbGmfy!TCT!QPMZ!H!U#-!#YusbGmfy!TCT!HMBTT!H#-!#YusbGmfy!TCT! HMBTT!HU#!ps!#FMBTUPTIJFME!UT!H!GS#-!ifbu!gvtfe/ iuuq;00qspevdutqfd/vm/dpn0epdvnfou/qiq@je>UHGV/S25682 Gps!npsf!jogpsnbujpo-!dpoubdu!Qpmzhmbtt!Ufdiojdbm!! Tfswjdft!Efqbsunfou!ps!wjtju!xxx/qpmzhmbtt/vt Low Slope Application A,B,C 1,2,3,4,5,6,7 Asphaltic Shingles A,B,D 1,2,4,5,6,7 Concrete or Clay Tile 1,2,3,4,5,6,7 A,B,D,E 1,2,3,4,5,6,7 A,B,D Metal Roofs 1,2,4,5,6,7 Wood Shingles and Shakes A,B,D Other 1,2,3,4,5,6,7 As Applicable 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component Product Approval 5. Municipal Permit Application 6. Owner’s Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing / Calculation Documentation Permit Number: _______________ Kantuta Corp Contractor’s Name: _________________________________________________________________________ 209 SW 4 St. Boynton Beach FL 33435 Job Address: _______________________________________________________________________________ 5 Mechanically Fastened Tile Low Slo Mortar / Adhesive Set Tile Metal Panel/ Shingles 5 Asphaltic Shingles Wood Shingles / Shakes 5 New RoofRepairMaintenanceReroofingRecovering Low Slope Roof Area ()Total () Steep Sloped Roof A() 1792 2270 478 _________________________ ___________________________________________________ Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. Top Ply Fastener/ Bonding Material: Self Adhered ___________________________________________ Surfacing: Polyglass USA, Inc. System Manufacturer: __________________________ |NA _____________________________________ 19-0307.04 Fastener Spacing for Anchor/Base Sheet Attachment: Product Approval # ____________________________ Design Wind Pressures, rom RAS 128 or Calculations: 8 3 8 -37 -84 -64 _____oc @ L, #Rows _____@ _____ oc : _______ : _______ ________ -117 4 4 4 _____oc @ L, #Rows____@____c Max. Design Pressure, from the specific product 4 4 4 _____oc @ L #Rows _____@ _____oc -52.5 approval system: ______________________________ 4 44 Deck CDX plywood Type:____________________________________ 19/32 Gauge / Thickness:____________________ <.125/12 Slope:_________________________________ NA NA : _____ _____: _____NA NA Elastobase Anchor/ Base Sheet & No. of Ply(s): ____________ Anchor/ Base Sheet Fastener/ Bonding Material: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, 1-1/4" ring shank nail on 1-5/8" tin caps _____________________________________________ Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc. NA Insulation Base Layer: ___________________________ Mean Roof Height, Parapet Height, Height Base Flashing, NA Base Insulation Size and Thickness: _____________ Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit Manufactures Details that Comply with RAS 111 Base Insulation Fastener/ Bonding Material: and Chapter 16. NA _____________________________________________ NA Top Insulation Layer: ____________________________ NA Top Insulation Size and Thickness: ________________ Top Insulation Fastener/Bonding Material: Cap Sheet NA _____________________________________________ Interply Base NA Base Sheet(s) & No. of Ply(s): _____________________ Base Fastener/ Bonding Material: 10' NA _____________________________________________ Elastoflex SAV Ply Sheet(s) and No. of Ply(s): ___________________ Ply Sheet Fastener/ Bonding Material: Self Adhered 2" 26 ga. Galv Drip. _____________________________________________ Elastoflex SA P FR or Polyflex SA P FR, Top Ply: ___________________________________ CertainTeed Roof System Manufacturer: ____________________________________________________________ 20-0723.14 Number:____________________________________________________ Minimum Design Wind Pressures, Applicable RAS 127 or Calculations: -108 -128 -74-108 -74-108 1: ______: ______ X X Deck Type: 19/32" CDX Plywood #30 Felt Underlayment: Roof Slope: 3 _______: 12 NA Insulation: NA Fire Barrier: 1-1/4" ring shank nails on 1-5/8" t.c. 6" Ridge Ventilation? Fastener Type & Spacing: o.c. @ laps & 2 rows @ 12" o.c. field na NA NA 12' Mean Roof Height: _____________ CertainTeed dim. shingle Roof Covering: 2" face 26 ga. Galvanized Drip Edge: GCD!218!.!!SFNJOEFS .!3131!GCD!Sftjefoujbm!8ui!Fejujpo!sfrvjsft!uif!jotubmmbujpo!pg!uxp mbzfst!pg!xbufs!cbssjfs!)voefsmbznfou* Tff;!S:16/2/2/2/5!.!Voefsmbznfou!gps!btqibmu-!nfubm-!njofsbm tvsgbdfe-!tmbuf!boe!tmbuf.uzqf!sppg!dpwfsjoht