Loading...
PERMIT DOCUMENTS MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISIONMiami, Florida 33175-2474 T (786)315-2590F (786) 3152599 www.miamidade.gov/economy NOTICE OF ACCEPTANCE (NOA) TAMKOBuilding ProductsLLC P.O. Box 1404 601 North High Street Joplin, MO 64801 S COPE: This NOA is being issued under the applicable rules and regulations governing theuse of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER -Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (in Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. D ESCRIPTION:TAMKOUnderlayments L ABELING:Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. R ENEWALof this NOA shall be considered after a renewal application has been filed and there has been no change in the applicablebuilding code negatively affecting the performance of this product. T ERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of thisNOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. A DVERTISEMENT:The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. I NSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revisesNOA No. 17-0531.01and consists of pages 1 through 9. The submitted documentationwas reviewed by Hamley Pacheco, P.E. NOA No.: 19-0917.04 Expiration Date: 07/05/22 Approval Date: 01/16/20 Page 1of 9 R OOFING C OMPONENT A PPROVAL Category:Roofing Sub-Category:Underlayment Material:SBS S COPE: This approves TAMKOUnderlayments, as described in this Notice of Acceptance; designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. T RADE N AMES OF P RODUCTS M ANUFACTURED OR L ABELED BY A PPLICANT: ProductDimensionsTestProductDescription Specification TW Metal and Tile 39 "wideASTM D 1970Self-adhering rubberized asphalt underlayment. Underlayment Manufacturing Location #1 Moisture Guard 36" wideASTM D 1970Self-adhering rubberized asphalt underlayment. Manufacturing Location #1 TW Underlayment39 "wideASTM D 1970Self-adhering rubberized asphalt underlayment. Manufacturing Location #2 TAMKOSA Base39"wideASTM D 1970Self-adhering rubberized asphalt base sheet.Direct Manufacturing adhesion to wood deck not permitted in the HVHZ. Location #1Shall only be mechanically fastened to wood deck. Do Not Remove Release Film! TAMKO SA Cap39"wideASTM D 6164Self-adhering rubberized asphalt cap sheet surfaced with Manufacturing Type Igranules. Location #1 AWAPLAN39 "wideASTM D 6164Polyester SBS modified membrane surfaced with granules. Manufacturing Type I Location #1 AWAPLANTULASTM D 6164Polyester SBS modified membrane surfaced with granules. Manufacturing Type I Location #1 M ANUFACTURING L OCATION: 1.Joplin, MO 2.Columbus, KS NOA No.: 19-0917.04 Expiration Date: 07/05/22 Approval Date: 01/16/20 Page 2of 9 E VIDENCE S UBMITTED: Test AgencyTest IdentifierTest Name/ReportDate T11090.09.08TAS 117(B)/ TAS 114(C)09/18/08 TrinityERD PRI Asphalt Technologies, Inc.TAP-191-02-01ASTM D197011/16/07 TAP-192-02-01ASTM D197011/13/07 TAP-193-02-01ASTM D197011/16/07 TAP-185-02-01REVASTM D616411/06/08 TAP-196-02-01ASTM D197001/09/08 TAP-324-02-01TAS 114-9511/11/15 TAP-238-02-01ASTM D460108/25/10 TAP-262-02-01ASTM D460101/24/12 TAP-262-02-02ASTM D197001/24/12 TAP-298-02-01ASTM D616411/10/15 TAP-298-02-03ASTM D616405/10/17 TAP-366-02-01TAS 103 (Section 19)05/24/17 TAP-366-02-01ASTM D162305/24/17 TAP-367-02-01ASTM D162305/02/17 TAP-367-02-03TAS 103 (Section 19)05/09/17 TAP-311-02-01ASTM D197010/19/17 TAP-473-02-01ASTM D616406/04/19 TAP-458-02-01ASTM D197012/02/19 TAP-462-02-01ASTM D197001/21/19 TAP-428-02-01ASTM D197008/30/18 TAP-432-02-01ASTM D197008/30/18 847T0005TAS 103 (Section 19)12/02/19 A PPROVED A SSEMBLIES: Deck Type 1:Wood, Non-insulated 19 Deck Description:/" or greater plywood or wood plank 32 System E(1):Anchor sheet mechanically fastened to deck, membrane adhered. Base Sheet: ck with approved annularringshank nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c. the field of the roll. Membrane:One or more plies of TW Metal and Tile Underlayment end lap. Place the first course of membrane parallel to the eave rolling the membrane to obtain maximum contact. Remove the release liner as the membrane is applied. Vertical strapping of the roof with TW Metal and Tile Underlaymentis acceptable. Surfacing: Approved Metal Roofing Assembly or Approved Roofing Assemblies where an ASTM D1970 underlayment is allowed. NOA No.: 19-0917.04 Expiration Date: 07/05/22 Approval Date: 01/16/20 Page 3of 9 Deck Type 1:Wood, Non-insulated 19 Deck Description:/" or greater plywood or wood plank 32 System E(2):Anchor sheet mechanically fastened to deck, membrane adhered. Base Sheet:One or more plies of ASTM D226 Type II or ASTM D annularringshank nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c. the field of the roll. Membrane:One or more plies of Moisture Guard Place the first course of membrane parallel to the eave rolling the membrane to obtain maximum contact. Remove the release liner as the membrane is applied. Vertical strapping of the roof with Moisture Guardis acceptable. Surfacing: Approved Roofing Assemblies where an ASTM D1970 underlayment is allowed. Deck Type 1:Wood, Non-insulated 19 Deck Description:/" or greater plywood or wood plank 32 System E(3):Anchor sheet mechanically fastened to deck, membrane adhered. Base Sheet: annularringshank nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c. the field of the roll. Membrane:One or more plies of TW UnderlaymentPlace the first course of membrane parallel to the eaverolling the membrane to obtain maximum contact. Remove the release liner as the membrane is applied. Vertical strapping of the roof with TW Underlaymentis acceptable. Surfacing: Approved Roofing Assemblies where an ASTM D1970 underlayment is allowed. Deck Type 1:Wood, Non-insulated 19 Deck Description:/" or greater plywood or wood plank 32 System E(4):Anchor sheet mechanically fastened to deck, membrane adhered. Base Sheet:One or more plies of ASTM D226 Type II or ASTM D2626 with a annularringshank nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c.inthe field of the roll. 0 Membrane:One or more plies ofAWAPLANor AWAPLANTUL applied at a right angle (90) to the slope of the deck adhered in a full mopping of approved asphalt applied within the EVT range at a rate of 20-40 lbs./sq. Vertical strapping of the roof with AWAPLANor AWAPLANTULunderlayments is acceptable. When used in Tile roof systems the cap sheetshall be back nailed to deck with approved end laps. No nails or tin caps shall be exposed. Surfacing: Approved Mechanically Fastened or MortarAdhered Tile or Metal Roofing Assembly or Approved Roofing Assemblies where an ASTM D6164underlayment is allowed. NOA No.: 19-0917.04 Expiration Date: 07/05/22 Approval Date: 01/16/20 Page 4of 9 Deck Type 1:Wood, Non-insulated 19 Deck Description:/" or greater plywood or wood plank 32 System E(5):Anchor sheet mechanically fastened to deck, membrane adhered. Base Sheet:One or more plies of TAMKOSA Base,ASTM D226 Type II or ASTM D2626with a annular ringshank nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c. in the field of the roll. Shall only be mechanically fastened to wood deck. Direct adhesion to wood deck not permitted in the HVHZ.Do Not Remove Release Film! Membrane:One or more plies of TAMKOSA Cap the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact with base sheet. Remove the release liner as the membrane is applied. Vertical strapping of the roof with TAMKOSA Cap underlayment is acceptable. When used in Tile roof systems the cap sheetshall be back nailed to deck with approved the end laps. No nails or tin caps shall be exposed Surfacing: Approved Mechanically Fastened or Mortar Adhered Tile or Metal Roofing Assembly or Approved Roofing Assemblies where an ASTM D6164 membrane is allowed. Deck Type 1:Wood, Non-insulated 19 Deck Description:/" or greater plywood or wood plank 32 System E(6):Anchor sheet mechanically fastened to deck, membrane adhered. Base Sheet:One or more plies ofASTM D226 Type II or ASTM D2626 fastened to deck with approved annularringshank nails and tin caps 6" o.c. at the laps and threestaggered rows 6" o.c. the field of the roll. Membrane:One or more plies of TAMKOSA Cap the first courseof membrane parallel to the eave, rolling the membrane to obtain maximum contact with base sheet. Remove the release liner as the membrane is applied. Vertical strapping of the roof with TAMKOSA Cap underlayment is acceptable. When used in Tile roof systems the cap sheetshall be back nailed to deck with approved the end laps. No nails or tin caps shall be exposed Surfacing: Approved Mechanically Fastened or Mortar Adhered Tile or Metal Roofing Assembly or Approved Roofing Assemblies where an ASTM D6164 membrane is allowed. NOA No.: 19-0917.04 Expiration Date: 07/05/22 Approval Date: 01/16/20 Page 5of 9 Tile Staging/StackingDetail SideView -St FrontView - G ENERAL L IMITATIONS: 1.Fire classification is not part of this acceptance. 2.This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. TAMKOUnderlaymentsshall be installed in strict compliance with applicable Building Codes. 3.All TAMKOUnderlaymentsshall be applied to a smooth, clean and dry surface with deck free of irregularities. Deck shall be fastened in strict compliance with applicable Building Codes. 4.All TAMKOUnderlaymentsshall not be applied over an existing roof membrane as a recover system but may be applied over an approved roofing Base/Anchor sheet underlayment. 5.TW Metal and Tile Underlayment, Moisture Guard, TW Underlayment, TAMKOSA Base andTAMKOSA Capshall not be left exposed as a temporary roof for longer than 30 days of application. 6.AWAPLANand AWAPLANTUL shall not be left exposed as a temporary roof for longer than 180 days of application. 7.The standard maximum roof pitch for TAMKOSA Cap shall be 4:12 for flat tile and profiled tiles with lugs. See Tile Staging/Stacking Detail. 8.The standard maximum roof pitch for AWAPLANand AWAPLANTULshall be 4:12 for flat tile and profiled tiles with lugs.See Tile Staging/Stacking Detail. 9.Tile storage shall be on a battens or toe boardswhen the underlayment slope limit (See #7 & #8 above) is exceeded. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of tile directly on the underlayment. 10.Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. 11.The TAMKOUnderlaymentsmay be used with any approved roof covering Notice of Acceptance listing the TAMKOUnderlaymentas a component part of an assembly in the Notice of Acceptance. If TAMKO Underlaymentsare not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami- Dade County Product Control Sectionfor approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. 12.All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application. NOA No.: 19-0917.04 Expiration Date: 07/05/22 Approval Date: 01/16/20 Page 6of 9 G ENERAL L IMITATIONS: 13.When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. For ridge applications, center the membrane and roll from the center outward in both directions. 14.For the self adhered membranes roll or broom the entire membrane surface so as to have 100% contact with the base sheet, giving special attention to overlap areas. 15.Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 16.All protrusions or drains shall be initially taped with a 6" piece of approved TAMKOUnderlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of the same TAMKOUnderlayment shall be applied over the taped underlayment. 17.All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 18.All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city, stateand the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. NOA No.: 19-0917.04 Expiration Date: 07/05/22 Approval Date: 01/16/20 Page 7of 9 TAMKO APPLICATION GUIDANCE SPECIFIC TO THIS NOA FOR THE FOLLOWING PRODUCTS WHEN USED AS UNDERLAYMENTS P LEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. L OCAL CODES MAY SUPERSEDE THE TAMKO REQUIREMENTS AND RECOMMENDATIONS LISTED BELOW. Moisture Guard 1. TAMKO accepts direct adhesion to wood decks in situations where direct deck installation is permitted by applicable local building codes. 2. Moisture Guard is not to be used in any situation that requires permanent exposure. 3. TAMKO permits application with roll length parallel to roof slope at slopes at or above 21:12. All side and end laps must be rolled with a roofing seam roller in addition to brooming the entire surface. TW Metal and Tile Underlayment 1. TAMKO accepts direct adhesion to wood decks in situations where direct deck installation is permitted by applicable local building codes. 2. TW Metal and Tile Underlayment is not to be used in any situation that requires permanent exposure. 3. When used as a concrete or clay tile underlayment TAMKO requires mechanical fastening of every tile regardless of slope or tile attachment method. 4. Minimum elapsed time after installation and before loading of concrete or clay roof tiles is 48 hours. 5. TAMKO permits application with roll length parallel to roof slope at slopes at or above 21:12. All side and end laps must be rolled with a roofing seam roller in addition to brooming the entire surface. TW Underlayment 1. TAMKO accepts direct adhesion to wood decks in situations where direct deck installation is permitted by applicable local building codes. 2. TW Underlayment is not to be used in any situation that requires permanent exposure. 3. TAMKO permits application with roll length parallel to roof slope at slopes at or above 21:12. All side and end laps must be rolled with a roofingseam roller in addition to brooming the entire surface. TAMKO SA Base 1. TAMKO accepts direct adhesion to wood decks in situations where direct deck installation is permitted by applicable local building codes. 2. SA Base isnot to be used in any situation that requires permanent exposure. 3. TAMKO permits application with roll length parallel to roof slope at or above ¾:12. All side and end laps must be rolled with a roofing seam roller in addition to brooming the entire surface. 4. When mechanically-fastening SA Base, the release liner may be left in place. Fasten the sheet along the side lap at intervals of no more than 8 inches. Stagger fasteners on no more than 16 inch centers along two lines located 13 inches from each edge of the base sheet. NOA No.: 19-0917.04 Expiration Date: 07/05/22 Approval Date: 01/16/20 Page 8of 9 TAMKO APPLICATION GUIDANCE SPECIFIC TO THIS NOA FOR THE FOLLOWING PRODUCTS WHEN USED AS UNDERLAYMENTS P LEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. L OCAL CODES MAY SUPERSEDE THE TAMKO REQUIREMENTS AND RECOMMENDATIONS LISTED BELOW. TAMKO SA Cap 1. TAMKO accepts direct adhesion to wood decks in situations where direct deck installation is permitted by applicable local building codes. 2. SA Cap is permitted to be used as a concrete or clay tile underlayment for mechanically-fastened or mortar-set tile. When used with mortar attachment of tile, TAMKO requires mechanical fastening of every tile regardless of slope. 3. Minimum elapsed time after installation and before loading of roof tiles is 48 hours. 4. TAMKO permits application with roll length parallel to roof slope at slopes at or above ¾:12. All side and end laps must be rolled with a roofing seam roller in addition to brooming the entire surface. 5. All adhesive-to-granule laps must be formed using TAMKO TWM-1 Mastic, TAM-PRO Q-15 Elastomeric Flashing Cement or TAM-PRO Q-20 Premium SBS Flashing Cement as directed in the applicable TAMKO application instructions. 6. Damage to the membrane that occurs during installation must be repaired by setting a patch of SA Cap that extends a minimum of 6 inches beyond the damaged area on all sides in TAM-PRO Q-15 Elastomeric Flashing cement or TAM-PRO Q-20 Premium SBS Flashing Cement. AWAPLAN 1. AWAPLANis permitted to be used as a concrete or clay tile underlayment for mechanically- fastened tile. 2. TAMKO permits application with roll length parallel to roof slope at slopes at or above ¾:12. 3. Damage to the membrane that occurs during installation must be repaired by setting a patch of AWAPLANthat extends a minimum of 6 inches beyond the damaged area on all sides in TAM- PRO Q-15 Elastomeric Flashing cement or TAM-PRO Q-20 Premium SBS Flashing Cement. AWAPLANTUL 1. AWAPLANTUL is permitted to be used as a concrete or clay tile underlayment for mechanically- fastened or mortar-set tile. 2. TAMKO permits application with roll length parallel to roof slope at slopes at or above ¾:12. 3. Damage to the membrane that occurs during installation must be repaired by setting apatch of AWAPLANTUL that extends a minimum of 6 inches beyond the damaged area on all sides in TAM-PRO Q-15 Elastomeric Flashing cement or TAM-PRO Q-20 Premium SBS Flash͵ END OF THIS ACCEPTANCE NOA No.: 19-0917.04 Expiration Date: 07/05/22 Approval Date: 01/16/20 Page 9of 9 .!SFNJOEFS!.!uif!jotubmmbujpo!pg!uxp!mbzfst!pg!xbufs!cbssjfs )voefsmbznfou*!qfs!uif!3131!Gmpsjeb!Cvjmejoh!Dpef!.!Sftjefoujbm .!8ui!Fejujpo!.!Tff;!S:16/2/2/2/5!.!Voefsmbznfou!gps!btqibmu- nfubm-!njofsbm!tvsgbdfe-!tmbuf!boe!tmbuf.uzqf!sppg!dpwfsjoht MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 www.miamidade.gov/economy NOTICE OF ACCEPTANCE (NOA) CertainTeed LLC 20 Moores Road, Malvern, PA 19355 S COPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (in Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. D ESCRIPTION: CertainTeed XT-25 Three Tab Shingles L ABELING:Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. R ENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. T ERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. A DVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. I NSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA #20-0723.05 and consists of pages 1 through 4. The submitted documentation was reviewed by Alex Tigera. NOA No.: 21-0315.01 Expiration Date: 06/14/26 Approval Date: 05/13/21 Page 1 of 4 R OOFING A SSEMBLY A PPROVAL Category: Roofing Sub-Category: Asphalt Shingles Materials: 3-Tab Deck Type: Wood S COPE This approves CertainTeed XT-25 Three Tab Shingles as manufactured by CertainTeed LLC described in this Notice of Acceptance. P RODUCT D ESCRIPTION Product Dimensions Test Product Description Specifications CertainTeed XT-25 12" x 36"TAS 100A heavyweight, fiberglass reinforced 3-tab asphalt shingle. Manufacturing Locations #1, 2 Accessory Shingles variousproprietaryAccessory shingles for hip, ridge and starter strip applications. M ANUFACTURING L OCATION 1. Oxford, NC 2. Shreveport, LA NOA No.: 21-0315.01 Expiration Date: 06/14/26 Approval Date: 05/13/21 Page 2 of 4 E VIDENCE S UBMITTED: Test Agency Test Identifier Test Name/Report Date PRI Construction Materials Technologies CTC-022-02-01 TAS-100 05/16/06 CTC-103-02-01 TAS-100 10/17/11 CTC-104-02-01 TAS-100 10/31/11 CTC-099-02-01 TAS-100 09/08/11 CTC-100-02-01 TAS-100 09/26/11 CTC-077-02-01 TAS-100 04/25/11 CTC-078-02-01 TAS-100 04/26/11 Underwriters Laboratories, Inc. 06CA11166 TAS 107 05/22/06 06CA02645 TAS 107 01/20/06 11CA38844 TAS 107 01/28/12 06CA28237 TAS 107 09/22/06 04CA17822 TAS 107 05/28/04 ASTM D 3462 04/05/06 11NK08333 ASTM D 3462 11/05/12 11NK08333 ASTM D 3462 11/20/12 11NK08333 ASTM D 3462 04/15/12 11NK08333 ASTM D 3462 11/05/12 4789552696 ASTM D 3462 04/30/11 4789552696 ASTM D 3462 03/12/21 Follow-up Service Letter ASTM E 108 08/25/04 L IMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. I NSTALLATION 1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail 'A', attached. 5. Nailing shall be in compliance with Detail 'B', attached. L ABELING 1.Shingles shall be labeled with the Miami-Dade Product Control approved seal as seen below or the wording ÐMiami-Dade County Product Control ApprovedÑ. NOA No.: 21-0315.01 Expiration Date: 06/14/26 Approval Date: 05/13/21 Page 3 of 4 B UILDING P ERMIT R EQUIREMENTS As required by the Building Official or the applicable Building Code in order to properly evaluate the installation of this system. This Notice of Acceptance on its own cannot be used to obtain a building permit. D ETAIL A Rake 6th 30'' off 5th 24'' off Deck 4th 18'' off 3rd 12'' off 2nd 6'' off Starter 1st Eaves D ETAIL B 36'' 12'' 5 5/8'' 5'' END OF THIS ACCEPTANCE NOA No.: 21-0315.01 Expiration Date: 06/14/26 Approval Date: 05/13/21 Page 4 of 4