Loading...
PERMIT DOCUMENTS TUSVDUVSF TzmwftusjK!1703703132 BQQSPWFE TUSVDUVSF TzmwftusjK!1703703132 TUSVDUVSF TzmwftusjK!1703703132 DESIGN CRITERIA: APPLICABLE CODES, REGULATIONS & STANDARDS SHEET NO.DRAWING INDEX 1. THE 2020 FLORIDA BUILDING CODE, SPECIFICALLY CHAPTER 16 STRUCTURAL DESIGN, CHAPTER 20 ALUMINUM & CH. 23 WOOD. S/01 GENERAL NOTES 2. AA ASM 35 & SPECIFICATIONS FOR ALUMINUM STRUCTURES, PART 1-A OF THE ALUMINUM DESIGN MANUAL PREPARED BY S/02 PLAN/ ELEVATIONS THE ALUMINUM ASSOCIATION, INC. WASHINGTON D.C. 2005 ED. 3. ASCE 7-16 & SE17 S/03 DETAILS 4. NDS NATIONAL DESIGN SPECIFICATION FOR WOOD. 5. ACI318 CONCRETE REFERENCE MANUAL. S/04 DETAILS WIND LOADS S/05 DETAILS 1. BUILDING OCCUPANCY CATEGORY, PARAGRAPH 1604.5 & TABLE 1604.5: RISK CATEGORY 1. 2. BASIC WIND SPEED, TABLE 1609C, STATE OF FLORIDA DEBRIS REGION & BASIC WIND SPEED, PARAGRAPH 1609.3.1 & TABLE 160 1609.3.1 EQUIVALENT BASIC WIND SPEED: C MPH EXPOSURE CATEGORY, PARAGRAPH 1609.4.3: 3. WIND LOADS PER FBC TABLE 2002.4 (MWFRS) VULT = 160 MPH & EXPOSURE = C FOR 20 X 20 X 0.013" MESH SCREEN 49 PSF HORIZONTAL PRESSURES ON WINDWARD SURFACES = 39 PSF HORIZONTAL PRESSURES ON LEEWARD SURFACES = 14 PSF VERTICAL PRESSURES ON SCREEN SURFACES = BQQSPWFE 41 PSF VERTICAL PRESSURES ON SOLID SURFACES = TUSVDUVSF .88 TzmwftusjK!1703703132 FOR 18 X 14 X 0.013" MESH SCREEN, APPLIED FACTOR = .6 FOR ALLOWABLE STRESS DESIGN, APPLIED FACTOR = FOUNDATION DESIGN FOOTING SIZE EXISTING CONCRETE SLAB. NO ADDITIONAL FOOTING OR FOUNDATION SYSTEM IS REQUIRED BY THE PROPOSED CONSTRUCTION IF A MINIMUM 4" CONCRETE SLAB IS PROVIDED IN SOUND CONDITION, FREE FROM STRUCTURAL CRACKING, SPALLING & OTHER DETERIORATION. EXISTING FOUNDATION/FOOTING UNDER CONCRETE SLAB MINIMUM 8"x8" W/ (1) #5 BAR TO BE VERIFIED BY CONTRACTOR. SEE TYPICAL FOOTING DETAILS FOR NEW FOOTING DESIGN MINIMUM REQUIREMENTS. MISCELLANEOUS 1. SCREENED ENCLOSURES CONTAINING SWIMMING POOLS SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF FBC R4501.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS. 2. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME. IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPARATE 4TH WALL SUPPORT SYSTEM IS SO TO BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. FASTENER SPECIFICATIONS 1. FASTENERS ARE REQUIRED TO BE SAE GRADE 2 OR BETTER ZINC PLATED. (CONCRETE ANCHORS ARE TO BE TAPCONS OR BETTER, INSTALLED TO MFG. SPECIFICATIONS) 2. IT IS THE OWNERS RESPONSIBILITY TO MAINTAIN THE SCREENS, FASTENERS AND SCREENS TO MANUFACTURING SPECIFICATIONS. 3. WHERE WOOD DECK IS PRESENT USE 1/4" X 3-1/2" GALV. LAG SCREWS IN LIEU OF MASONRY ANCHORS. UNLESS OTHERWISE SPECIFIED. 4. 1"X2" NON STRUCTURAL MEMBERS ATTACHED TO HOST A. FOR MASONRY/CONCRETE APPLICATION USE GALVANIZED 1/4" X 2-3/4" TAPCONS OR EQUAL AT 24" O.C. AND 6" FROM ENDS B. FOR WOOD APPLICATION USE #14 X 2-3/4" WOOD SCREW AT 24" O.C. AND 6" FROM ENDS. C. FOR ALUMINUM APPLICATION USE #10 X 1-1/2" SMS OR TEK SCREW AT 24" O.C. AND 6" FROM ENDS D. WHERE 1"X2" INSTALLED THROUGHOUT AN "OPEN VIEW" SPACING SHALL BE REDUCED TO 18" O.C. AND 6" FROM ENDS RENDERING IS NOT TO SCALE & IS JUST A GENERALIZED RESPONSIBILITIES DEPICTION OF THE TYPE OF STRUCTURE PROPOSED 1. ALL SITE WORK SHALL BE PERFORMED BY A LICENSED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDANANCES, AND THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES. 2. FOR FASTENERS WHICH ARE NOT VISIBLE AFTER INSTALLATION, PROPOSED HIP GABLE SCREEN ENCLOSURE THE CONTRACTOR SHALL VERIFY AND ENSURE INSTALLATION HAS BEEN ACCOMPLISHED IN ACCORDANCE WITH SEE FOUNDATION DESIGN SHEET-01 MANUFACTURERS SPECIFICATIONS AND IN ACCORDANCE WITH THE ATTACHED DETAILS. 3. FOR "PICTURE WINDOW" MODIFICATION TO EXISTING SCREEN ENCLOSURES, ALL OTHER "EXISTING SCREEN ENCLOSURE" FEATURES ARE TO MEET THE TYPICAL DETAILS AS PROVIDED IN THESE DETAILS. CONTRACTOR IS TO VERIFY & ASSURE EXISTING SCREEN ENCLOSURE IS STRUCTURALLY SOUND. DESIGN DATE:06/13/2021 4. CONTRACTOR TO PROVIDE NOA'S & INSTALL ALL MATERIALS REVISION 1:DATE AS PER MANUFACTURER'S SPECIFICATIONS. 5. INTEGRITY OF EXISTING/ HOST STRUCTURE SHALL NOT BE REVISION 2:DATE SHEET: COMPROMISED WITH THE ATTACHMENT OF THE PROPOSED STRUCTURE. DRAWN BY:ST 01 SCALE:NTS ALUMINUM SPECIFICATIONS 1. ALUMINUM EXTRUSIONS SHALL BE 6005 T5 ALLOY UNLESS OTHERWISE NOTED. 2. ALL SELF MATING BEAM SECTIONS ARE TO BE STITCHED WITH #12 SCREWS 6" FROM ENDS & 24" CENTER TO CENTER. #10 SCREW 6" FROM ENDS & 12" CENTER TO CENETER. 3. ROOF BRACING SHALL BE A MINIMUM 2"X2"X.050". 4. THE MINIMUM NORMAL THICKNESS OF PROTECTOR PANELS (KICKPLATES) SHALL BE AN INDUSTRY STANDARD OF 0.024 INCHES. 5. VINYL AND ACRYLIC PANELS SHALL BE REMOVED WHEN RESIDENCE WIND SPEEDS EXCEED 75 MPH PER FBC. 6. SCREEN MATERIAL SHALL BE 18/14 SCREEN UNLESS APPROVED BY FLORIDA ENGINEERING LLC. 7. 1"X2" & 1"X3" NON STRUCTURAL MEMBERS MAY BE USED 3"HEADERWALLMOUNT INTERCHANGEABLY. 8. DOOR LOCATION MAY BE RELOCATED BY CONTRACTOR IN THE FIELD. 3"X.032"X1LB BQQSPWFE COMPOSITEPANELS TUSVDUVSF TzmwftusjK!1703703132 3003H154 1/4"1'SLOPE(MIN.) (FL.#7561.1R5) 10'0" 2X7SMBW/S.G. 1X2 1X2 2X2DJ DJ 2X4SMB 2X2TYP. 2X4SMB 1X2 1X2 5'0" 21'0" 8'0"8'0" 4'0"MAX 1X2+2X2 1X2TYP. EXISTINGCBSWALL DESIGN DATE:06/13/2021 REVISION 1:DATE REVISION 2:DATE SHEET: 5'0"5'0"5'0"6'0" DRAWN BY:ST 02 SCALE:NTS ALUMINUM MEMBERS DIMENSIONS (2) #10x3" SMS INTO SCREW HOLLOW SECTIONS 1"x2" FASTEN TO COL. (INTERNAL) BOSSES FOR EDGE MEMBER w/(2) #10x1-1/2" SMS, FASTEN TO 2 x 2: 2" x 2" x 0.050" EAVE RAILS ABOVE w/#10 1-1/2" SMS 2 x 3: 2" x 3" x 0.050" 24" O.C. AND 6" WITHIN COL. 2 x 4: 2" x 4" x 0.050" 2 x 5: 2" x 5" x 0.050" TABLE "D" BEAM PER PLAN (SLOPED OR FLAT) OPEN BACK SECTIONS EDGE MEMBER QTY/ SIZE EACH SIDE OR PURLIN BEAM 1 x 2: 1" x 2" x 0.044" 1 x 3: 1" x 3" x 0.045" 2 x 3 (4)/ #12 SNAP SECTIONS EDGE MEMBER (2) #10x2" 2 x 4 (5)/ #12 BEAM PER PLAN 2 x 2 SNAP: 2" x 2" x 0.045" OR PURLIN INTO BEAM NOTCHED TO RECEIVE 2 x 3 SNAP: 2" x 3" x 0.050" 2 x 5 (5)/ #12 COLUMN WITHIN 2 x 4 SNAP: 2" x 4" x 0.045" BEAM BRACE 2 x 6 (6)/ #12 SMS, (EACH SIDE) 0.0625" 6063-T6 FLAT PLATE INSTALL BRACE SELF MATING (SMB) QTY/ SIZE PER TABLE "D" 2 x 7 (7)/ #12 w/(8) #10x.75" SMS, MIN. .5" TO CORNER 2 x 4 SMB: 2" x 4" x 0.046" x 0.100" EDGE DISTANCE, PLATE MAY BE 2 x 8 (8)/ #14 BQQSPWFE FASTENED INTERNALLY TO BRACE 2 x 5 SMB: 2" x 5" x 0.050" x 0.116" NOTCH PROFILE MAY VARY TUSVDUVSF 2 x 6 SMB: 2" x 6" x 0.050" x 0.120" 2 x 9 (9)/ #14 TO PERMIT CORRECT # SMS PURLIN TzmwftusjK!1703703132 2 x 7 SMB: 2" x 7" x 0.055" x 0.120" 2 x 10 (9)/ #14 2 x 8 SMB: 2" x 8" x 0.072" x 0.224" COLUMN PER PLAN 2 x 9 SMB: 2" x 9" x 0.072" x 0.224" MAINTAIN MIN, OF 5/8" SEPERATION 2 x 9(H) SMB: 2" x 9" x 0.082" x 0.306" FROM EDGE OF BEAM SMS O.C. 2 x 10 SMB: 2" x 10" x 0.092" x 0.374" DETAIL A DETAIL E - UPRIGHT TO BEAM DETAIL "D" - ROOF BRACING CONNECTION CONNECTION SCALE: NTS SCALE: NTS ALUMINUM INTERNAL OR EXTERNAL MINIMUM NUMBER OF TAPCONS INTO CONCRETE & RECEIVING CHANNEL w/(4) #10x.75" # 12 X 3/4" S.M.S. INTO UPRIGHT / EACH SIDE OF BEAM INTO GIRT OR PURLIN & (2) #14x.75" THROUGH SECONDARY 2" X 2" X 0.125" ANGLES INTO BEAM OR UPRIGHT 0.062 ANGLE (4) #10x1-1/2" SMS INTO (SEE BELOW)CLIPS MAYBE USED SCREW BOSSES 2X4 S.M.B. (1) 1/4" X 2-1/4" S.S. TAPCON & (2) # 12 X 3/4" S.M.S. 2X5 S.M.B. (1) 1/4" X 2-1/4" S.S. TAPCON & (2) # 12 X 3/4" S.M.S. FASTEN TOP OF HEADER TO INTERSECTING 2X6 S.M.B. (2) 1/4" X 2-1/4" S.S. TAPCON & (3) # 12 X 3/4" S.M.S. 2"x2" MEMBER w/(2) #10 SMS w/1" PENETRATION INTO SCREW BOSS OF 2X7 S.M.B. (2) 1/4" X 2-1/4" S.S. TAPCON & (4) # 12 X 3/4" S.M.S. 2"x2" MEMBER - TYP. BOTH SIDES 2X8 S.M.B. (3) 1/4" X 2-1/4" S.S. TAPCON & (5) # 12 X 3/4" S.M.S. 2X9 S.M.B. (4) 1/4" X 2-1/4" S.S. TAPCON & (6) # 12 X 3/4" S.M.S. 2X10 S.M.B. (5) 1/4" X 2-1/4" S.S. TAPCON & (7) # 12 X 3/4" S.M.S. PURLIN 2"x2" DOOR JAMB MEMBER SELF-MATING OR UPRIGHT, BEAM-SNAP, 1/8"x2"x2"x ANGLE SNAP SECTION TYP. SELF MATING, OR HOLLOW 5032 H-32 ANGLE (2) - #12 SMS INTO COLUMN 1"x2" O.B. BASE PLATE-TYP. 1/4" MASONRY ANCHOR EACH ANGLE - EACH SIDE COL. 1-1/4" MIN. CONC. FASTEN HEADER w/(2) #10x3" ANCHOR EMBEDMENT INTO SCREW BOSS OF HEADER DETAIL "C" - GIRT OR PURLIN TO BEAM OR POST DETAIL SCALE: NTS 2" MIN. INCREASE DISTANCE 2-1/4" MIN. CONC. ALTERNATE HEADER CONNECTION WHEN GREATER THAN 2x4 ANCHOR EMBEDMENT WHEN Z-BAR IS USED - FASTEN UPRIGHT IS USED SECONDARY ANGLE Z-BAR TO COL/HEADER AT EACH CORNER AND 18" O/C 3000 PSI CONC. 2"x2"x.063" - DIM. TO MATCH PURLIN SLAB/ FTG. SIZE RECEIVING CHANNEL 6x6-10x10 WWM (2) #12 SMS INTERNAL TO EAVE RAIL NOTE SIDE VIEW OR FIBERMESH (3) #12 EACH SIDE INTO PURLIN WHERE PAVERS ARE PRESENT USE 5/16" ALTERNATE BASE PLATE CONNECTION TAPCON XL (RED HEAD MFG.) MASONRY ATTACH 2"x2" TO BASE PLATE ANCHORS TO PENETRATE UNDERLYING (INTERNAL) w/(2) #10x2" SMS CONCRETE FOOTING 2-1/4" (MIN.) 1/4" MASONRY ANCHOR AT EACH ANGLE (2) - #12 SMS ATTACH BASE PLATE TO 2"x2" w/(2) #10x3" SMS INTO SCREW EAVE RAIL - SEE PLAN BOSS OF BASE PLATE 1/4" TAPCON XL (RED HEAD MFG. OR EQUAL) EXTRUSION 2 @ 1x2 BASE 1x2 OPEN BACK 2 @ SLAB (BEYOND) UPRIGHT EXTRUSION (2) #10x2" SMS THRU 1x2 INTO EAVE RAIL EACH SIDE OF COLUMN 1"x2" BASE PLATE ANCHORED TO CONC w/ 1/4" MASONRY ANCHOR 6" MAX EACH SIDE OF POST AND 24" O.C. MAX 1-1/4" CONC. EMBEDMENT TYP. 6" 3000 PSI CONC. SLAB/ FTG. DESIGN DATE:06/13/2021 1/4" TAPCON (RED HEAD MFG. OR EQUAL) WITHIN 6" OF 6x6-10x10 WWM FRONT VIEW COLUMN 1-1/4" PENETRATION INTO UNDERLYING FOOTING OR FIBERMESH DETAIL "G" - SLOPED PURLIN REVISION 1:DATE DETAIL "F" - DOOR JAMB & HEADER CONNECTION SCALE: NTS REVISION 2:DATE DETAIL "B" - 2"x4" OR LARGER SELF MATING SHEET: CONNECTION SCALE: NTS UPRIGHT TO DECK DETAILS SCALE: NTS DRAWN BY:ST 03 SCALE:NTS 1"x5"x2" WIDTH EXTRUDED GUTTER BRACKET GIRT FASTENED INTERNALLY AT EACH END Ejhjubmmz!tjhofe! (THICKNESS OF LEG @ WOOD SCREW SHALL BE w/ #10x1.5" EACH SCREW GROOVE. FASTEN 0.125" MIN., LONG LEG SHALL BE 0.072" MIN.) TO BEAM w/ 2"x2""x1/8" ANGLE (2) #12 SMS @ EACH BEAM w/(2) #12x3/4" SMS @ 1" SPACING cz!Dsbjh!F! INTO BEAM & (2) #10x1.5 THRU ANGLE INTO INTO GUTTER LIP. FOR BEAMS ABOVE 2x8 INSTALL GUTTER WHERE NO GIRT IS PRESENT, ATTACH GUTTER BRACE AT MIDPOINT BETWEEN BEAMS & ANGLE DIRECTLY TO GUTTER Hvoefstpo! INCLUDE 2" GUTTER BRACE AT EACH BEAM LOCATION. Ebuf;! BQQSPWFE .050" GUTTER STIFFNER 3132/17/25! TUSVDUVSF 2"x2"x1/8" ANGLEFASTEN TO FASCIA w(2) #12x2" WOOD SCREW w/(2) #12 SMS TzmwftusjK!1703703132 FASTEN TO GUTTER w(2) EACH LEG 29;22;53!.15(11( GUTTER #12 SMS EXISTING HOST STRUCTURE BRACE WHEN BEAM & PURLIN (DESIGNED BY OTHERS) HIT ON CORNER - BEAM FASTEN OUTSIDE OF BEAM & PURLIN (2) #12 SMS (2) #14 WOOD SCREWS @ 1" w/ 1/8"x2"x2" ANGLE SPACING @ EACH GUTTER BRACKET & (4) #12 SMS EACH LEG & (1) @ 18" O.C. MAX. MIN. EMBEDMENT SHALL BE 2" (9) #14x3/4" SMS CLOSE BOTTOM OF 1/8" PLATE ON 45° ANGLE BEAM WHEN TRIMMED OR 1/8"x2"x2" ANGLE w/(4) FOR BEAM OVER 2x5 .044 RECEIVING CHANNEL, #12 SMS INTO EACH .044 RECEIVING CHANNEL FASTEN TO STRUCTURAL GUTTER FASTEN w/(2) #12 SMS INTERSECTING MEMBER INTERNALLY w/(2) #12 SMS FASTEN INSIDE CORNER EACH SIDE OF BEAM ALTERNATELY 2x2x1/8" ANGLE BELOW GIRT, (2) #14 SMS INTO (BEAM TO PURLIN) BEAM & (2) #12 SMS INTO STRUCTURAL GUTTER w/ 1/8"x2"x2" ANGLE w/(2) #12 SMS INTO EA. MEMBER (BEAM & PURLIN) SIDE VIEW EYEBOLT FOR CABLE TENSION OPTIONAL GIRT PERIMETER DETAIL "M" BEAM & PURLIN TO GUTTER #10 SMS WITHIN 6" 1/8" STAINLESS STEEL FRAMING & @ 24" O.C. MAX. FASTEN GUTTER TO BRAIDED CABLE CONNECTION SCALE: NTS FASCIA w/ #14x2" WOOD SCREW 18" O.C. (2) #12 SMS DETAIL "I-2" CABLE CONNECTION AT CORNER SCALE: NTS GUTTER BRACE (2) #14x2" WOOD SCREW 2x2x1/8" ANGLE @ 1" SPACING EA. SIDE OF BEAM 1/8" STAINLESS STEEL w/(2) #12 SMS BRAIDED CABLE EACH LEG EACH SIDE (2) #14 WOOD SCREWS 40° MIN. FASCIA (2"x6" MIN. EXISTING) INTO FASCIA 60° MAX. (2) #12 SMS STRUCTURAL GUTTER 2"x2"x1/8" ANGLE w/(2) GIRT TOP VIEW #12 SMS EA. LEG DETAIL "H" BEAM TO GUTTER CONNECTION SCALE: NTS 3" A.S.T.M. A-36 STEEL CLIP 3000 PSI CONC. WITH (2) 3/8"x3" SLEEVE ANCHORS SMB 6x6-10x10 FOR PAVERS (2) 1/4"x6" TAPCONS WWM OR FIBERMESH THRU PAVERS INTO FOOTING GIRT F 1/8" STAINLESS STEEL BRAIDED CABLE 40° MIN. 1/8"x2"x4" STRAP F 60° MAX. STRUCTURAL GUTTER (2) #12 SMS INTO BEAM SIDE VIEW (2) #12 SMS INTO GUTTER F F F F 3/16"-5052-H32 GUSSET F INTERNAL OR EXTERNAL GIRT 3000 PSI CONC. 2 x 10 SMB ILLUSTRATED(2) GUTTER BRACES 6x6-10x10 3/8" DIA x 3" EMBED EACH w/(2) #12 SMS F WWM OR FIBERMESH FASCIA INTO GUTTER & (2) #14CONC. SCREW ANCHOR WOOD SCREWS INTO FASCIA(TAPCON OR EQUAL) TABLE B-1 GUTTER NOTE F COL. TO BEAM BEAM TO BEAM 1/8" STAINLESS STEEL 2"x2"x1/8" ANGLE w/(2) BEAM BRACE INSTALL FASTENERS ALONG PERIMETER OF GUSSET BRAIDED CABLE QTY SMS/QTY SMS/ #12 SMS EA. LEG SIZE -BEAM JOINT 3/8" MIN, FROM EDGE. FASTENERS 40° MIN. SIDE OF COL.EA. FACE/SIDE MAY BE STAGGERED TO INSURE PROPER 60° MAX. QUANTITY PER TABLE B-1 (5) #12(9) #12 2 x 4 (2) #12 SMS FASTENER PATTERN MAY APPEAR DIFFERENT (5) #12(9) #12 2 x 5 FROM ILLUSTRATION. MAINTAIN 1/2" SEPARATION BETWEEN FASTENERS. SMB (7) #12(9) #12 2 x 6 MAINTAIN 3/8" MIN, FASTENER SEPARATION FROM BEAM JOINT OR EDGE OF BEAM LAP (10) #12(10) #12 2 x 7 FASTENERS MAY BE EVENLY SPACED AROUND EDGE OF GUSSET WITHIN 3/8" OF BEAM JOINT.(12) #12(14) #12 2 x 8 1/8"x2"x4" STRAP FASTENERS MAY BE STAGGERED TO INSURE 3000 PSI CONC. GIRT (2) #12 SMS INTO BEAM (14) #14(14) #14 STRUCTURAL GUTTER PROPER QUANTITY PER TABLE B-1 2 x 9 6x6-10x10 1.5"x5.5" ALUM. STRAP (2) #12 SMS INTO GUTTER WWM OR FIBERMESH w/(2) 3/8" DIA. x 3" (16) #14(15) #14 DESIGN DATE:06/13/2021 2 x 10 MASONRY ANCHOR TOP VIEW (TAPCON OR EQUAL) REVISION 1:DATE DETAIL "L" CORNER CONNECTION DETAIL "I-1" CABLE CONNECTION REVISION 2:DATE SHEET: DETAIL "K" GUSSET CONNECTIONSCALE: NTS AT FOUNDATION SCALE: NTS DRAWN BY:ST SCALE: NTS 04 SCALE:NTS .024 FLASHING SEALED TO Ejhjubmmz!tjhofe! WALL (TYP.) 2"x2"x.063" - DIM. TO MATCH PURLIN cz!Dsbjh!F! SIZE RECEIVING CHANNEL EXISTING RAFTER (2) #12 SMS INTERNAL TO EAVE #14x4" S.M.S. w/ 1-1/4" Ø FENDER WASHER OR TRUSS RAIL (3) #12 EACH SIDE INTO PURLIN AND NEO-PRENE GASKET @ 12" O.C. Hvoefstpo! #14x1/2" S.M.S. W/ INTEGRAL 3/4"Ø WASHER AND #14x1/2" S.M.S. W/ INTEGRAL 3/4"Ø NEOPRENE GASKET @ 12" O.C., TOP & BOTTOM. WASHER AND NEOPRENE GASKET IF CLEARANCE PROHIBITS INSTALLATION OF TOP @ 12" O.C., TOP & BOTTOM Ebuf;! FASTENERS USE #14x4" S.M.S. W/ 1-1/4" Ø FENDER WASHER AND NEOPRENE GASKET @ 12" O.C. EXTRUDED OR BRAKE-FORMED ROOF HEADER 3132/17/25! EXTRUDED OR BRAKE-FORMED ROOF HEADER OR RECEIVING CHANNEL (0.044" MIN. THICKNESS) OR RECEIVING CHANNEL (0.044" MIN. THICKNESS) WITH MIN. 1-1/2" BEARING LEG. SECURE FASCIA TO EACH WITH MIN. 1-1/2" BEARING LEG. 29;22;57!.15(11( RAFTER TAIL W/ (1) 1/4" Ø x 4" LONG PAN HEAD LAG SCREWS (1) 1/4" Ø x 2" LAG SCREW @ 24" O.C. CARRIER BEAM BEFORE ATTACHING REC. CHANNEL ENTIRE LENGTH OF RECEIVING CHANNEL PER PLAN HOST STRUCTURE 1/4" Ø x 2-1/2" LONG WOOD LAG SCREW OR MASONRY OR WOOD 1/4" Ø x 2-1/4" LONG MASONRY ANCHORS ROOF PANEL ATTACHMENT - WOOD FRAME @ 24" O.C. MAX. PURLIN TO CARRIER BEAM + SOLID ROOF SCALE: N.T.S. CONNECTION SCALE: N.T.S. ROOF PANEL ATTACHMENT - MASONRY SCALE: N.T.S. BQQSPWFE TUSVDUVSF TzmwftusjK!1703703132 1"x5"x2" WIDTH EXTRUDED GUTTER BRACKET (THICKNESS OF LEG @ C.B. SCREW SHALL BE #14x4" S.M.S. w/ 1-1/4" Ø FENDER WASHER 0.125" MIN., LONG LEG SHALL BE 0.072" MIN.) AND NEO-PRENE GASKET @ 12" O.C. (2) 3/8" DIA. MACHINE @ EACH BEAM w/(2) #12x3/4" SMS @ 1" SPACING BOLTS THRU CARRIER INTO GUTTER LIP. (2) #14 SMS OT TEK SCREWS @ 1" #12 X 9/16" W/ 5/8" NEO-WASHER CARRIER BEAMBEAM & POST GIRT FASTENED INTERNALLY AT EACH END SPACING @ EACH GUTTER BRACKET & (1) @ 18" O.C. (3) PER PAN FOR PANS PER PLAN w/ #10x1.5" EACH SCREW GROOVE. FASTEN MAX. (SEE NOTE) TO BEAM w/ 2"x2""x1/8" ANGLE (2) #12 SMS 1"x5"x3" WIDTH EXTRUDED GUTTER BRACKET NOTE: INTO BEAM & (2) #10x1.5 THRU ANGLE INTO (THICKNESS OF LEG @ #14 SMS OR TEK SHALL BE FOR BEAMS ABOVE 2x8 INSTALL 3X3 OR 4X4 GUTTER WHERE NO GIRT IS PRESENT, ATTACH 0.125" MIN., LONG LEG SHALL BE 0.072" MIN.) GUTTER BRACE AT MIDPOINT BETWEEN BEAMS & POST PER PLAN ANGLE DIRECTLY TO GUTTER @ 24" O.C. w/(2) #12x3/4" SMS @ 1" SPACING INCLUDE 2" GUTTER BRACE AT EACH BEAM LOCATION INTO GUTTER LIP. (2) #14 SMS OR TEK @ 1" *FOR 2X9 AND 2X10 CAGE SPACING @ EACH GUTTER BRACKET USE #14 INTO BEAM BEAM & (1) @ 18" O.C. MAX. (2) 3/8" THRU-BOLT & (3) 1/4" TAPCON BEAM TO POST CONNECTION #1 STRUC. THRU CARRIER BEAM INTO HOST 2-1/4" MIN. GUTTER*FOR 2X9 AND 2X10 & POSTS DETAIL SCALE: N.T.S. USE #14 INTO BEAM GIRT FASTENED INTERNALLY AT EACH END & (3) 1/4" TAPCON CAGE w/ #10x1.5" EACH SCREW GROOVE. FASTEN INTO HOST 2-1/4" MIN. BEAM TO BEAM w/ 2"x2""x1/8" ANGLE (2) #12 SMS INTO BEAM & (2) #10x1.5 THRU ANGLE INTO #14x4" S.M.S. w/ 1-1/4" Ø FENDER WASHER POST GUTTER WHERE NO GIRT IS PRESENT, ATTACH AND NEO-PRENE GASKET @ 12" O.C. (2) #12 SMS (2) 3/8" DIA. MACHINE ANGLE DIRECTLY TO GUTTER 3X3 OR 4X4 BOLTS THRU CARRIER SIDE VIEW 5 OR 7 IN. CARRIER BEAM POST PER PLAN BEAM & POST STRUCTURAL PER PLAN FOR BEAM OVER 2x5 FOR BEAM OVER 2x5 GUTTER .044 RECEIVING CHANNEL FASTEN .044 RECEIVING CHANNEL FASTEN TO STRUCTURAL GUTTER TO STRUCTURAL GUTTER CARRIER BEAM INTERNALLY w/(2) #12 SMS 3X3 OR 4X4 PER PLANINTERNALLY w/(2) #12 SMS SIDE VIEW ALTERNATELY 2x2x1/8" ANGLE POST PER PLAN ALTERNATELY 2x2x1/8" ANGLE BELOW GIRT, (2) #14 SMS INTO BELOW GIRT, (2) #14 SMS INTO BEAM & (2) #12 SMS INTO GUTTER BEAM & (2) #12 SMS INTO GUTTER BEAM TO POST CONNECTION #2 ROOF PANEL TO CARRIER BEAM W/ GUTTER + ROOF BEAMBEAM TO CARRIER BEAM W/ GUTTER + SOLID ROOF DETAIL SCALE: N.T.S.CONNECTION SCALE: N.T.S.CONNECTION SCALE: N.T.S. MAY USE: (4) 3/8"x5" TAPCON (4) 3/8"x4" TAPCON THRU IN LIEU OF 1/2" DIA. ANCHORS BOTTOM LEG OF ANGLE (4) 1/4"x3-1/4" TAPCON 1" INTO CONC. MAY USE: (2) 3/8"x4" TAPCON (2) 1/2" DIA. EXPANSION BOLTS THRU BOTTOM LEG OF (3) 1/4" DIA. MACHINE SEE NOTE #2 THIS PAGE ANGLE INTO CONC. IN LIEU OF 3/8" DIA. ANCHORS BOLTS w/ WASHERS (3) 1/4" DIA. MACHINE FOR BOLT PLACEMENT (2) 3/8" DIA. MACHINE (2) 3/8" DIA. EXPANSION BOLTS 2" BOLTS w/ WASHERS BOLTS w/ WASHERS SEE NOTE #1 THIS PAGE (2) 3/8" DIA. MACHINE FOR BOLT PLACEMENT BOLTS w/ WASHERS 2" FROM EDGE 1"3-3/4" FROM EDGE 3-3/4" FROM EDGE OF SLAB/ FTG. 2" FROM EDGE 3-3/4" FROM EDGE OF SLAB/ FTG. OF SLAB/ FTG. OF SLAB/ FTG. OF SLAB/ FTG. 3-3/4" FROM EDGE OF SLAB/ FTG. TOP VIEWMAY USE (4) #14x1" TEK (3) 1/4" DIA. MACHINE TOP VIEW TOP VIEW MAY USE (3) #14x1" TEK TOP VIEW BOLTS w/ WASHERS IN LIEU OF THRUBOLTS (2) 3/8" DIA. MACHINE IN LIEU OF THRUBOLTS 3"x3" POST 3"x3" POST4"x4" POST COLUMN PER PLAN BOLTS w/ WASHERS PER PLAN(SEE PAGE-2(SEE PAGE-2 (3) 1/4" DIA. MACHINE (2) 1/2" DIA. EXPANSION (2) 3/8" DIA. EXPANSION BOLTSFOR SIZE)FOR SIZE) (2) 3/8" DIA. MACHINE BOLTS w/ WASHERS BOLTS SEE NOTE #2 SEE NOTE #1 THIS PAGE BOLTS w/ WASHERS 1/8"x2"x2"x3-3/4"THIS PAGE FOR BOLT 1/8"x2"x3" FOR BOLT PLACEMENT MAY USE (4) #14x1" TEK MAY USE (3) #14x1" TEK (LENGTH) ANGLEPLACEMENT (LENGTH) ANGLE IN LIEU OF THRUBOLTS (INTERNAL) IN LIEU OF THRUBOLTS(4) 3/8"x4" TAPCON (4) 1/4"x3-1/4" TAPCON (INTERNAL) THRU BOTTOM LEG THRU BOTTOM LEG OF 2"x4"x0.125 ANGLE 3"x3"x0.125 ANGLEOF ANGLE INTO CONC. ANGLE INTO CONC. 3000 PSI CONC. 3000 PSI CONC. 3000 PSI CONC. 3000 PSI CONC. SLAB/ FTG.SLAB/ FTG.SLAB/ FTG.SLAB/ FTG. DESIGN DATE:06/13/2021 6x6-10x10 WWM 6x6-10x10 WWM 6x6-10x10 WWM 6x6-10x10 WWM OR FIBERMESHOR FIBERMESHOR FIBERMESHOR FIBERMESH REVISION 1:DATE FRONT VIEWFRONT VIEWFRONT VIEW REVISION 2:DATE SHEET: 3"x3" POST CONNECTION DETAIL3"x3" POST CONNECTION DETAIL4X4 COLUMN ALT. BASE ATTACHMENT4"x4" POST CONNECTION DETAIL DRAWN BY:ST (INTERNAL BASE) SCALE: N.T.S. SCALE: NTSDETAIL SCALE: NTS SCALE: NTS 05 SCALE:NTS