Loading...
PERMIT DOCUMENTS BQQSPWFE TUSVDUVSF HmbttI!1801203132 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 www.miamidade.gov/economy NOTICE OF ACCEPTANCE (NOA) Polyglass USA Inc. 1111 W. Newport Center Drive Deerfield Beach, FL 33442 S COPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER -Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOAshall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (in Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. D ESCRIPTION:Polyglass Polystick Underlayments L ABELING:Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. R ENEWALof this NOA shall be considered after a renewal application has been filed and there has been no change in theapplicable building code negatively affecting the performance of this product. T ERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. A DVERTISEMENT:The NOAnumber preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. I NSPECTION:A copy of this entire NOAshall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No.15-0410.04 and consists of pages 1 through 8. The submitted documentation was reviewed by Freddy Semino. NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 1of 8 BQQSPWFE TUSVDUVSF HmbttI!1801203132 R OOFING C OMPONENT A PPROVAL Roofing Category: Underlayment Sub-Category: SBS , APP Self-Adhering Modified Bitumen Material: P RODUCTS D ESCRIPTION: TestProduct ProductDimensionsSpecificationDescription 3 65'x 3'3-/"ASTM D 1970A fine granular/sand top surface self-adhering, APP Polystick IR-Xe 8 Or 65'x 3'polymer modified, fiberglass reinforced, bituminous Manufacturing 60 mils thicksheet material for useas an underlayment in sloped roof Location#1 & #2 assemblies. Designed as an ice & rain shield. 3 61'x 3'3-/"TAS 103 and A rubberized asphalt self-adhering, glass-fiber/polyester Polystick Dual Pro 8 60 mils thickASTM D 1970reinforced waterproofing membrane. Designed as a Manufacturing metal roofing and roof tile underlayment. Location#2 3 61'x 3'3-/"TAS 103 and A rubberized asphalt self-adhering, glass-fiber/polyester Polystick Tile Pro 8 60 mils thickASTM D 1970reinforced waterproofing membrane. Designed as a metal Manufacturing roofing and roof tile underlayment. Location#2 65'8"x 3'3-3/8"TAS 103 and A rubberized asphalt self-adhering, polyester reinforced Polystick TU Max 60 mils thickASTM D 1970waterproofing membrane. Designed as a a roof tile Manufacturing underlayment. Location#1 & #2 3 32'10"x 3'3-/"TAS 103 and A rubberized asphalt waterproofing membrane, glass- Polystick TU P 8 130 mils thickASTM D 1970fiber/polyester reinforced, with a granular surface Manufacturing designed for use as a tile roof underlayment. Location#2 3 65'x 3'3-/"TAS 103 and A rubberized asphalt self-adhering, glass-fiber/polyester Polystick TU Plus 8 (Surface Printing)80 mils thickASTM D 1970reinforced waterproofing membrane. Designed as a metal roofing and roof tile underlayment. Manufacturing Location#1 & #2 3 65'8"x 3'3-/"TAS 103A homogeneous, rubberized asphalt waterproofing Polystick MTS 8 60 mils thickmembrane, glass fiber reinforced with polyolefinic film Manufacturing on the upper surface for use as an underlayment for metal Location#2 roofing, roof tile, slate tiles and shingle underlayment. 3 65'8"x 3'3-/"TAS 103A homogeneous, rubberized asphalt waterproofing Polystick MTS Plus 8 60 mils thickmembrane, glass fiber reinforced with polyolefinic film Manufacturing on the upper surface for use as an underlayment for metal Location#2 roofing, roof tile, slate tiles and shingle underlayment. 32'10"x 3'3-"TAS 103 and Polyester reinforced, SBS modified bitumen membrane Elastoflex S6 G ASTM D 6164with a sanded back face and a granule top surface. For Manufacturing use in roof tile underlaymentsystems. Location#2 NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 2of 8 BQQSPWFE TUSVDUVSF HmbttI!1801203132 M ANUFACTURING P LANTS: 1. Hazelton, PA 2. Winter Haven, FL E VIDENCE S UBMITTED Test AgencyTest IdentifierTest Name/ReportDate Trinity | ERDP10870.09.08-R1TAS 10312/04/08 P10870.04.09TAS 103/ASTM D4798 & G15504/13/09 P33360.06.10ASTM D197007/01/10 P33370.03.11TAS 10303/02/11 P33370.04.11ASTM D 162304/26/11 P36900.09.11TAS 103/ASTM D4798 & G15509/01/11 P37300.10.11TAS 110/ASTM D4798 & D197010/19/11 P40390.08.12-2ASTM D 162308/07/12 P37590.07.13-1ASTM D616407/02/13 P45270.05.14TAS 103, TAS 110 & ASTM D162305/12/14 P46520.10.14ASTM D162310/03/14 P44360.10.14TAS 103 & TAS 11010/07/14 P43290.10.14ASTM D 1970 & TAS 11010/17/14 PLYG-SC10130.06.16-3TAS 103 & TAS 11006/27/16 PLYG-10130.06.16-1ASTM D1970 & TAS 11006/27/16 PRI Asphalt TechnologiesPUSA-035-02-01TAS 10309/29/06 PUSA-055-02-02TAS 10312/10/07 PUSA-089-02-01TAS 103/ASTM D4798 & G15507/06/09 Momentum Technologies, Inc.JX20H7ATAS 103/ASTM D4798 & G15504/01/08 RX14E8ATAS 103/ASTM D4798 & G15511/09/09 DX23D8BTAS 103/ASTM D4798 & G15502/18/10 DX23D8ATAS 103/ASTM D4798 & G15502/18/10 L ABELING: 1.All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facilityand the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. B UILDING P ERMIT R EQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 3of 8 BQQSPWFE TUSVDUVSF HmbttI!1801203132 I NSTALLATION P ROCEDURES: Wood, non-insulated Deck Type 1: Min. 19/32"plywood or wood plank Deck Description: Anchor sheet mechanically fastened to deck, membrane adhered System Type E(1): One or more plies of ASTM D 226 Type II or ASTM D 2626. Anchor/Base Sheet: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for Fastening: base sheet only) Membrane:Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS or Polystick MTS Plus,self-adhered. See General Limitations Below. Surfacing: Wood, non-insulated Deck Type 1: Min. 19/32"plywood or wood plank Deck Description: Anchor sheet mechanically fastened to deck, membrane adhered System Type E(2): One or more plies of ASTM D 226 Type II or ASTM D 2626. Anchor/Base Sheet: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for Fastening: base sheet only) Membrane:Elastoflex S6 G, hot asphalt applied See General Limitations Below. Surfacing: Wood, non-insulated Deck Type 1: Min. 19/32"plywood or wood plank Deck Description: System Type E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self-adhered. One or more plies of ASTM D 226 Type II or ASTM D 2626. Anchor/Base Sheet: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for Fastening: base sheet only) Ply Sheet:Polystick MTS Plus, self-adhered with minimum 3"horizontal laps and minimum 6" vertical laps. Membrane:Polystick TU Plus, self-adhered. See General Limitations Below. Surfacing: NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 4of 8 BQQSPWFE TUSVDUVSF HmbttI!1801203132 I NSTALLATION R EQUIREMENTS: All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose deck panels, and 1. sweep the deck thoroughly to remove any dust and debris prior to application. Place the underlayment over metal drip edge in accordance with RAS 111. 2. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. 3. Remove the release film as the membrane is applied. All sidand end laps shall be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. When applying the membrane in the valley, start at the low point and work to the high point, rolling the 4. membrane from the center outward in both directions. For ridge applications, center the membrane and roll from the center outward in both directions. 5. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention 6. to lap areas. Flash vent pipes, stacks, chimneys and penetrations in compliance with RoofAssembly current Product Control 7. Notice of Acceptance. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be 8. pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. G ENERAL L IMITATIONS: Fire classification is not part of this acceptance. 1. 2.Polystick Dual Pro, Polystick Tile Pro, Polystick TU Plus, Polystick MTSandPolystick MTS Plusmay be used in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, roof tile systems and quarry slate roof assemblies. Polystick TU Pmay be used in all the previous assemblies listed except metal roofing. Polystick IR-Xemay be used in all the previous assemblies listed except metal roofing and roof tile systems. Polystick TU Maxmay be used in non-structural metal roofing and roof tile systems. Elastoflex S6 Gmay be used in roof tile systems only. Deck requirements shall be in compliance with applicable building code. 3. 4.Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTSandPolystick MTS Plusshall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5.Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTSand Polystick MTS Plusshall not be adhered directly over a pre-existing roof membrane as a recover system. 6.Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTSand Polystick MTS Plusshall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. Exposure Limitations (Days) MTSIR-XeElastoflexTU TU PTile ProDual ProTU MaxMTS Plus S6 GPlus 18090180180180180180180180 Winter Haven, FL N/A90N/A180N/AN/AN/A180N/A Hazelton, PA All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and 7. NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 5of 8 BQQSPWFE TUSVDUVSF HmbttI!1801203132 Rule 61G20-3of theFlorida Administrative Code. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile 8. Polystick Tile Pro, Polystick TU Max, Polystick TU Plusor ElastoflexS6 Gmay be used in both adhesive set and mechanically fastened roof tile applications. Polystick Dual Prois limited to mechanically fastened roof tile applications. Polystick MTSand Polystick MTS Plusare limited to mechanically fastened with the limitations outlined in Section 9. Polystick TU Pmay be used in mechanically fastened roof tile applications with the exception of mortar set tile applications. When loading roof tilesonroof tile underlayment for (direct-to-deck) tile assemblies,the maximum roof slope 9. shall be as follows: (See Table Below) Tile Polystick Elastoflex Polystick TU Plus,Polystick Polystick System (E3) ProfileMTSS6 GTUP, Tile Pro, TU MaxMTS PlusMTS Plus with Dual ProTU Plus Flat TileProhibited 4:126:126:125:126:12 without battens Profiled Prohibited 4:126:126:124:126:12 Tilewithout battens The above slope limitations can be exceeded only by using battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements.When battens are required, they shall be utilized duringloading and installation of tiles. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of 10. tile directly on the underlayment.two tiles laid perpendicular to slope followed by a maximum four tile stack parallel to the slope, for a total of 6 tiles for all underlayments except Polystick MTSwhich shall be loaded onto battens. NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 6of 8 BQQSPWFE TUSVDUVSF HmbttI!1801203132 Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with 11. specific prepared roofing products. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 Gmay be used with any approved roof covering Notice of Acceptance listingPolystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plusor Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance. If Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plusor Elastoflex S6 Gare not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami-Dade County Product Control Sectionfor approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. P OLYGLASS G ENERAL A PPLICATION G UIDELINES FOR P OLYSTICK M EMBRANES P LEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. L OCAL CODES MAY SUPERSEDE P OLYGLASS REQUIREMENTS AND RECOMMENDATIONS. 1.Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codesprior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2.All rolls, with the exception of Polystick TU Plus should be back-nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1"metal disk as required in Miami-Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back-nailed. (Please refer to applicable local building codes prior to installation.) 3.All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. 4.All fabric over fabric; and granule over granule end laps, shall have a 6"wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium ModifiedWet/Dry Cement, Polyglass PG500 MB Flashing Cement, applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5.A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #9 and #10. 6.Battens and/or Counter-battens, as required by the tile manufacturers NOA, must be used on all projects for pitch/slopes of 7"/12"or greater. It is suggested that on pitch/slopes in excess of 6 ¼"/12", precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7.Minimum cure time after membrane installation & before loading of roofing tiles is Forty-Eight (48) Hours. 8.Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9.Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 7of 8 BQQSPWFE TUSVDUVSF HmbttI!1801203132 10.All self-adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11.All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12.The Polyglass Miami-Dade Notice of Acceptance (NOA) approval for Polystick membranes can be furnished upon request by our Technical Services Department by calling 1 (800) 894-4563. 13.Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800) 894-4563. 14.Polyglass recommends that applicatorsfollow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association (NRCA). P LEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. L OCAL CODES MAY SUPERSEDE P OLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 8of 8 BQQSPWFE TUSVDUVSF HmbttI!1801203132 BQQSPWFE TUSVDUVSF HmbttI!1801203132 ™ QuickSquares May24,2021 1501SW18thDr,BoyntonBeach, FL33426-6438Report:40418396 REPORTDETAILS Roof#1Area: 24Squares PredominantPitch:3 Thisreportincludesuptotwostructuresonaresidentialpropertyandonestructureonamulti-familyproperty.Thepitch hasbeenfactoredintothecalculationwithnowaste.PleaseupgradetoaPremiumReporttoreceivemeasurementsfor additionalstructuresandforanylowerroofareasthatmaybeobscuredfromviewinthetop-downimage,astheyarenot SatisfactionGuaranteed www.eagleview.com/Guarantee includedinthetotalsonthisreport. UpgradeYourReport! QuickSquaresisareportusedtoestimatetheoverallsizeoftheroof;formaterial-orderingaccuracy,contractorsshould upgradetoaPremiumReport.ThepriceofyourQuickSquaresreportwillbedeductedfromyourupgrade. APremiumReportincludes: AreaDiagram 3DRoofDiagram LengthDiagram PitchDiagram AerialImages(Top,N,S,E&W) NotesDiagram CustomizableReport WasteCalculationTable ReportSummary SquareFootagePitchTable ©2008-2021EagleViewTechnologies,Inc.andPictometryInternationalCorp.–AllRightsReserved– CoveredbyoneormoreofU.S.PatentNos.8,078,436;8,145,578;8,170,840;8,209,152;8,515,125;9,183,538;8,818,770;8,542,8 80;9,244,589; 9,329,749.OtherPatentsPending. TUSVDUVSF HmbttI!1801203132 TUSVDUVSF HmbttI!1801203132 TUSVDUVSF HmbttI!1801203132 TUSVDUVSF HmbttI!1801203132 TUSVDUVSF HmbttI!1801203132 TUSVDUVSF HmbttI!1801203132 TUSVDUVSF HmbttI!1801203132 TUSVDUVSF HmbttI!1801203132 TUSVDUVSF HmbttI!1801203132 TUSVDUVSF HmbttI!1801203132 TUSVDUVSF HmbttI!1801203132 TUSVDUVSF HmbttI!1801203132 BQQSPWFE TUSVDUVSF HmbttI!1801203132 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 www.miamidade.gov/economy NOTICE OF ACCEPTANCE (NOA) ICP Adhesives and Sealants, Inc. th 12505 NW 44 Street Coral Springs, FL. 33065 S COPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. ® D ESCRIPTION: PolysetAH-160 L ABELING:Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. R ENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. T ERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. A DVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. I NSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA 17-0322.03 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. NOA No.: 20-1124.07 Expiration Date: 05/10/22 Approval Date: 01/28/21 Page 1 of 11 BQQSPWFE TUSVDUVSF HmbttI!1801203132 R OOFING C OMPONENT A PPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane S COPE: ® This approves PolysetAH-160 as manufactured by ICP Adhesives and Sealants, Inc. as described in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS ® 127. For use with approved flat, low, and high profile roof tile systems using PolysetAH-160. P RODUCTS M ANUFACTURED BY A PPLICANT: ProductDimensionsTest Product Description Specifications ® PolysetAH-160 N/A TAS 101 Two component polyurethane foam adhesive ICP Adhesives Foam N/A Dispensing Equipment Dispenser RTF1000 ® ICP Adhesives ProPack N/A Dispensing Equipment 30 & 100 P RODUCTS M ANUFACTURED BY O THERS: Any Miami-Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment ® resistance values with the use of PolysetAH-160 roof tile adhesive. M ANUFACTURING L OCATION: 1. Tomball, TX. P HYSICAL P ROPERTIES: PropertyTestResults o Density @ 73F ASTM D1622 2.1 lbs./ft.³ Compressive Strength ASTM D1621 18 PSI Parallel to rise 14 PSI Perpendicular to rise Tensile Strength ASTM D1623 29 PSI Parallel to rise Water Absorption ASTM D2842 7% Moisture Vapor Transmission ASTM E96 2.3 Perms o Dimensional Stability ASTM D2126 +0.03% Volume Change @ -40 F., 2 weeks o -1.1% Volume Change @158F., 100% Humidity, 2 weeks Closed Cell Content ASTM D6226 94% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 20-1124.07 Expiration Date: 05/10/22 Approval Date: 01/28/21 Page 2 of 11 BQQSPWFE TUSVDUVSF HmbttI!1801203132 E VIDENCE S UBMITTED: Test AgencyTest IdentifierTest Name/ReportDate Center for Applied Engineering #94-060 TAS 101 04/08/94 257818-1PA TAS 101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 Miles Laboratories NB-589-631 ASTM D 1623 02/01/94 Polymers Division Trinity Engineering 7050.02.96-1 TAS 114 03/14/96 P36700.04.12 ASTM D 1623 04/18/12 P39740.02.12 TAS 101 02/21/12 TAS 123 Celotex Corp. Testing Services 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 520109-3 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109-2-1 NEMO ETC, LLC 4p-ICP-20-SSLAP-01.B-Physical Properties 12/4/20 R1 L IMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. ® 2. PolysetAH-160shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. ® 4. Roof Tile manufactures acquiring acceptance for the use of PolysetAH-160roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. NOA No.: 20-1124.07 Expiration Date: 05/10/22 Approval Date: 01/28/21 Page 3 of 11 BQQSPWFE TUSVDUVSF HmbttI!1801203132 I NSTALLATION: ® 1. PolysetAH-160may be used with any roof tile assembly having a current NOA that lists attachment resistance ® values with the use of PolysetAH-160. ® 2. PolysetAH-160shall be applied in compliance with the Component Application section and the corresponding ® Placement Details noted herein. The roof tile assemblyÓs adhesive attachment with the use of PolysetAH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami-Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. ® 3. PolysetAH-160and its components shall be installed in accordance with Roofing Application Standard RAS 120, and ICP Adhesives and Sealants, Inc.ÓsOperating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by ICP Adhesives and Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the ICP Adhesives Foam Dispenser RTF1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0-1.15 (A): 1.0 (B). ®® 6. PolysetAH-160shall be applied with ICP Adhesives Foam Dispenser RTF1000 or ICP Adhesives ProPack 30 & 100 dispensing equipment only. ® 7. PolysetAH-160shall not be exposed permanently to sunlight. ® 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after PolysetAH-160 has been dispensed. ® 9. PolysetAH-160placement and minimum patty weight shall be in accordance with the 'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. NOA No.: 20-1124.07 Expiration Date: 05/10/22 Approval Date: 01/28/21 Page 4 of 11 BQQSPWFE TUSVDUVSF HmbttI!1801203132 Table 1: Adhesive Placement For Each Generic Tile Profile Minimum Paddy Contact Minimum Paddy Gram Tile Profile Placement Detail Area Weight Eave Course - Flat, Low, High All Eave Course 17-23 sq. inches 45-65 Profiles Flat, Low, High Profiles #1 17-23 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 High Profile #2 17-19 sq. inches 30 Flat, Low, High Profiles #3 Two Paddys: 8-9 sq. inches at 12 grams per paddy head of tile 9-11 sq. inches at overlap Two-Piece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudinal 17 grams per bead edge) 20-25 sq. inches each bead Two Piece Barrel (Pan Tile) Two Piece 65-70 sq. inches 34 grams under pan L ABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami-Dade County Product Control Approved" or the Miami- Dade County Product Control Seal as shown below. B UILDING P ERMIT R EQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 20-1124.07 Expiration Date: 05/10/22 Approval Date: 01/28/21 Page 5 of 11 BQQSPWFE TUSVDUVSF HmbttI!1801203132 A DHESIVE P LACEMENT D ETAIL #1 Flat/Low Profile Tile 1.Starting at the eave course, apply a minimum 2Ñ (50.8 mm) x 10Ñ (254 mm) x 1Ñ (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock of the tile being set. 2.Continue in same manner. Insure approximately 17 22 (109.7 cm) Î 23 (148.4 cm) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile 1.Starting at the eave course, apply a minimum 2Ñ (50.8 mm) x 10Ñ (254 mm) x 1Ñ (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2.Continue in same manner. Insure approximately 17 22 (109.7 cm) Î 23 (148.4 cm) square inch adhesive contact with the underside of the tile. High Profile / Single Pan Tile 1.Starting at the eave course, apply a minimum 2Ñ (50.8 mm) x 10Ñ (254 mm) x 1Ñ (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2.Continue in same manner. Insure approximately 17 22 (109.7 cm) Î 23 (148.4 cm) square inch adhesive contact with the underside of the tile. NOA No.: 20-1124.07 Expiration Date: 05/10/22 Approval Date: 01/28/21 Page 6 of 11 BQQSPWFE TUSVDUVSF HmbttI!1801203132 A DHESIVE P LACEMENT D ETAIL #2 Flat/Low Profile Tile 1.Starting at the eave course, apply a minimum 2Ñ (50.8 mm) x 10Ñ (254 mm) x 1Ñ (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the overlock of 2 the tile being set. Insure approximately 17 (109.7 cm) 2 Î 23 (148.4 cm) square inch adhesive contact with the underside of the tile. 2.At the second course, apply a minimum 2Ñ (50.8mm) x 7Ñ (177.8 mm) x 1Ñ (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib closest to the overlock of the tile being set. 3.Continue in same manner. Insure approximately 10Ñ 22 (64.5 cm) - 12 (77.4 cm) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile 1.Starting at the eave course, apply a minimum 2Ñ (50.8 mm) x 10Ñ (254 mm) x 1Ñ (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the 2 tile being set. Insure approximately 17 (109.7 cm) Î 2 23 (148.4 cm) square inch adhesive contact with the underside of the tile. 2.At the second course, apply a minimum 2Ñ (50.8mm) x 7Ñ (177.8 mm) x 1Ñ (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3.Continue in same manner. Insure approximately 12Ñ 2 (77.4 cm2) - 14 (90.3 cm) square inch adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 20-1124.07 Expiration Date: 05/10/22 Approval Date: 01/28/21 Page 7 of 11 BQQSPWFE TUSVDUVSF HmbttI!1801203132 A DHESIVE P LACEMENT D ETAIL #2(C ONTINUED) High Profile / Single Pan Tile 1.Starting at the eave course, apply a minimum 2Ñ (50.8 mm) x 10Ñ (254 mm) x 1Ñ (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the 2 tile being set. Insure approximately 17 (109.7 cm) Î 2 23 (148.4 cm) square inch adhesive contact with the underside of the tile. 2.At the second course, apply a minimum 2Ñ (50.8mm) x 7Ñ (177.8 mm) x 1Ñ (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3.Continue in same manner. Insure approximately 17Ñ 22 (109.7 cm) - 19 (122.6 cm) square inch adhesive contact with the underside of the tile. NOA No.: 20-1124.07 Expiration Date: 05/10/22 Approval Date: 01/28/21 Page 8 of 11 BQQSPWFE TUSVDUVSF HmbttI!1801203132 A DHESIVE P LACEMENT D ETAIL #3 1.On the eave course only, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat tile or under the pan portion of the tile for low or high profile tile closest to the overlock of the tile being set. Leave approximately 4" (101.6 mm) up from the eave edge free of foam to prevent the expanded adhesive from blocking the weep holes. Insure 22 approximately 17-23 in (109.7-148.4 cm) of adhesive contact with the underside of the tile 2.Apply a 4" (101.6 mm) x 4" (101.6 mm) x 1" (25.4 mm) foam paddy onto the underlayment just below the second course line positioned foam paddy under the strengthening rib for flat tile, or under the pan portion of the tile, closest to the underlock for the second course tile to be installed. Insure 22 approximately 8-9 in (51.6-58.1 cm) of adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 20-1124.07 Expiration Date: 05/10/22 Approval Date: 01/28/21 Page 9 of 11 BQQSPWFE TUSVDUVSF HmbttI!1801203132 A DHESIVE P LACEMENT D ETAIL #3(C ONTINUED) 3.Also apply a 2" (50.8 mm) x 4" (101.6 mm) x đÑ (19 mm) paddy on top of the eave course tile surface as shown, on top of the strengthening rib for flat tile or on top of the pan portion of the tile, closest to the underlock of the first course of tile. Install second course of tile. Insure approximately 22 9 (58.1 cm) - 11 (71cm) square inch adhesive contact with the underside of the tile at the overlap 22 and 7 (45.2 cm) - 9 (58.1 cm) square inch adhesive contact with the underside of the tile at the head of the tile. Continue in same manner. NOA No.: 20-1124.07 Expiration Date: 05/10/22 Approval Date: 01/28/21 Page 10 of 11 BQQSPWFE TUSVDUVSF HmbttI!1801203132 A DHESIVE P LACEMENT D ETAIL T WO P IECE B ARREL Two Piece Barrel (Cap and Pan) Tile 1.Starting at the eave course, apply a minimum 2Ñ (50.8 mm) x 10Ñ (254 mm) x 1Ñ (25.4 mm) foam paddy onto the underlayment positioned as shown under two adjacent pan tiles. Support eave tiles from rocking until adhesive has a chance to cure. 2.Continue in same manner bringing two pan courses up toward the ridge. Insure 22 approximately 65 (419.4 cm) Î 70 (451.6 cm) square inch adhesive contact with the underside of the pan tile. 3.Turn covers upside down exposing the underside of the tile. Apply a minimum 1Ñ (25.4 mm) x 10Ñ (254 mm) bead of adhesive directly on the inner edge of each side of the cover tile. Leave approximately 3/4Ñ (19 mm) to 1Ñ (25.4 mm) from the outside edge of the tile, inward, free of foam to allow for expansion. 4.Turn cover tile over after foam is applied and place onto pan tile course. Insure a minimum of 22 20 (129 cm) - 25 (161.3 cm) square inch contact area on each side of the cover tile to the pan tile. Continue in same manner. Trim away any cured exposed foam adhesive. Pointing of longitudinal edges of the cover tiles are considered optional. 5.When additional nailing is required, 2Ñ (50.8 mm) x 4Ñ (101.6 mm) nailers or the tie wire system using galvanized, stainless steel, or copper wire and compatible nails may be used. END OF THIS ACCEPTANCE NOA No.: 20-1124.07 Expiration Date: 05/10/22 Approval Date: 01/28/21 Page 11 of 11