Loading...
CERT OF OCCU • . Pest Related Services Pre-Construction Termite Treatment 1-800-698-7998 • - - _ License #4439 Property Information Builder / Contractor Information Treatment Date,—\3:: I Time: K \4o V ' Name of Builder Lot __9_ Block . C()LSO b1 M„y. Shell Contractor Subdivision Name 4� 6 Wlnei 1c1 Circle Constructio ype Street Address (if Monolithic Floating/ Stemwall frl0h L Patio Entry Driveway City f State Zip Owner Name (if known) Product / Treatmen,>�Information • __ . . Treatment Type (Must check one): Initial Under-Slab-Supplemental Wood TreatmentFinal— Product applied: Bifenthrin ' Bora-Care Othe ✓l'hr44610frid . Concentration: . OSl%I Mixed Product Applied: 2 31 Gallons L 3) Square feet treated: 3 Linear feet treated: • ❑ If box is checked, then either a final perimeter liquid treatment has been completed or a wood treatment is completed and the following statement is applicable: CERTIFICATE OF COMPLIANCE: The building has received a complete treatment for the prevention of subterranean termites. Treatment is in accordance with the rules and laws established by the Florida Department of Agriculture and Consumer Services. K et iv, A \ ki - Applicator's Name (Please Print) Advantage is a Full Service pest control company offering inside pest control, termite control, and lawn & ornamental insect protection and fertilization programs. We offer discounts to our Termite renewal customers! Call 1-800-698-7998 for more information. 2800 NW 22"" Terrace, Pompano Beach, FL 33069 (954) 968-7717 fax(954) 968-2922 www.advantagepest.com 9,0- 4206 SPECIALTY ENGINEERING CONSULTANTS, INC. 1699 SW 30TH AVENUE,SUITE 620 BOYNTON BEACH,FL 33426 TEL:561.7626440 FAX:661-7524642 PALM BEACH,BROWARD AND DADE COUNTIES FIELD DENSITY TEST LABORATORY NUMBER: 33975 CLIENT: K Hovnanian PROJECT: Casa Del Mar CONTRACTOR: SOIL DESCRIPTION: Gray CGS with rock LOCATION: Lot 29-slab on grade PERFORMED BY: JF DATE: Wednesday,December t6,2020 PROCTOR VALUE(pct): 119.8 OPTIMUM MOISTURE: (T) 11.8 LAB 0: 4200 RESULTS OF TESTS: TEST LIFT No. TEST LOCATIONS PROBE DRY MOIST. %FIELD SPEC PASS I No. (ELEV.) DEPTH DEN. (%) COMP. REO. FAIL (Pei) 1 FG Northwest corner 12" 117.9 11.9% 98.4% 98% PASS 2 FG Center 12" 117.5 12.4% 98.1% 98% PASS 3 FG Southeast corner 12" 118.2 11.2% 98.7% 98% PASS 4 5 B 7 8 9 10 11 ' 12 13 14 15 FIELD REPORT GIVEN TO: John CONCLUSION:THE ABOVE TEST RESULTS DO COMPLY WITH PROJECT SPECIFICATIONS UNLESS NOTED' BF:BACKFILL 5:SUBGRADE BC:BASE COURSE NG:NATURAL GROUND PF:PAD FILL F:FOOTING CP:COLUMN PAD BG:BELOW GRADE FG:FINAL GRADE OTHER: NOTE.STANDARDS FOR METHOD OF TEST:ASTM 02922 '..„I”„„,,,TEST RESULTS INDICATE THE TOTAL DEPTH BELOW EXISTING GRADE AT PROBE DEPTH ONLY AND DOES NOT REFLECT �”Rn1E$OI A$4RWO CAPACITY FOR FOUNDA HON DESIGIKERTIFICA•• AS STANDARD PENETRA HON TEST BORINGS WOULD DETERMINE. ?SPIT-( t h. - 1N t. ULTANTS,INC. • No, 15683 DISTRIBUTION: r.,� O ,ARK = T : ' 1/1321 S 474 E ern -4'4',5583W 4-cro NQ i.e.W is SS S,, /o, j EN00 • Z:10uatTOVtPROJECTS\Case Del Mar\Densilies\121620133975-lot 29 SOG.xls