DRAWINGS
VERIFY ALL DIM`s., WALL & COL. HGT`s. , GIRDER ,CLG. COFFER CLG. & COL. LOCATIONS, END DETAIL , PITCH , FASCIA , O.H & CANT. DIM.`s SOME DOWN FRAMING REQ. BY BLDR. @ DROP CLG. ,
CLG. CHANGE & COFFER CLG. AREAS
INDICATES LEFT END OF TRUSS
WHEN REVIEWING ENGINEERING SHEETS
THIS WILL BE THE LEFT SIDE OF THE PAGE
CONN.FLOORTRUSS
HANGER IDROOFUPLIFTGIRDER
A 2x6 12-10dx1 1/2"
THD26
30602645226518-16d
B 2x8 16-10xd1 1/2"
THD28
44854115233028-16d
C 2x6
THD26-233552770234018-16d12-10d
D 2x6
THDH-26-2
52454375234020-16d8-16d
2x6
E
THDH26-3
52454375234020-16d8-16d
2x8
F
THD28-250054310259528-16d16-10d
G 2x8
THDH28-2
80257360333036-16d10-16d
H 2x8
THDH28-3
78357595437036-16d12-16d
2x6
I
THD4631752540228518-16d12-10d
J 2x6
HJC26
3490-----213516-16d5-10d
K 2x6
SKHH46L/R
21001680134512-16d6-16d
2x6 12-10dx1 1/2"
L
SKHH26L/R18901510219018-16d
M 2x6 4-16dx2 1/2"
SKHH26L-2/R-22100168089512-16d
N
0
2x8
O
GTWS2T
109008720834522-WS316-WS3
P 2x8
GTWS3T12470111001249028-WS324-WS3
Q 2x8
GTWS4T
12470111001249028-WS324-WS3
MSTAM24/HTWM20CONN.5-1/4"
R
----------15459-10d
OR EQUAL
BY BLDR.Tapcon
S
T
X
Y
Z
CONN. BY BLDR.
FOR APPROVAL PURPOSES ONLY. DO NOT USE TO SET TRUSSES
UNLESS STAMPED «FINAL» HERE
A1
Ejhjubmmz!
tjhofe!cz!
DBSM!H!
GPSCFT!
C a r l G . F o r b e s
Ebuf;!
3132/15/38!
P . E . # 2 0 6 9 9
25;5:;52!
.15(11(
1000 S. Dixie HWY W.
Pompano Beach Fl 33060
A5
CUSTOMER
NAME
JOB
NAME
JOB
ADDRESS
DATE
JOB
#
TRUSS PLACEMENT PLAN