Loading...
PERMIT APPLICATIONBP200101 CITY OF BOYNTON BEACH Application Inquiry li/26/02 09:22:59 Application number ..... : 01 00004705 Application status, date : FINALED Property .......... : 2400 NE 1ST LN 308 PCN ............. : 08-43-45-16-13-006-3080 Lot Number ......... : 11/25/02 Zoning ........... : R3 MULTI FAMILY (10.80) Application type ...... : RW REPLACE WINDOWS Application date ...... : 12/03/01 Tenant nbr, name ...... : 3 WINDOWS Master plan nbr, revwd by : RA Estimated valuation .... : 1600 Total square footage .... : 0 Public building ...... : NO Work description, qty . . . : Pin number ......... : 9331 Press Enter to continue. F3=Exit F5=Land inq F10=Fees F11=Receipts F7=Appl names F12=Cancel F8=Tracking inq F13=Val calcs F9=Bond inquiry F24=More keys BUILDING DIVISION BUILDING pERMIT APPLIgATION (Please Print) -4705 Rec. # ' ' Permit. · (FOR SUB PERMITSONLY) (Paln~ Beach Coun~ Pmpe~y C~ Ow~r's'P~e ff ~5 -~ , . . S~te ~l Zip .~3~. STATE OF FLORIDA, C.O~QF.~P~L', :BEACH who, ~)~~~~~, ~ ' . ...... "'.=ti"~ti~'~"~ did (da not) lin''e~ -'~--~ ~ ~--~ ~ommission ~[r~ ~24;2~ ' Comm~ion ~ CC 7315~5 (S~) _, printed or stamped , ,[TitE. g6r rank ..... _ ....... · I~tefial Number. if any /~-..'~/.~;'~ ~ Nofary Public - State of FloricJaf I'nate Contractor's Signature The foregoing instrument was acknowledged before me Ihis //~-~/~/' ' ' (dale) by ~:>/~,~/Ir who is personally known to me or. who has produced as idenfirmafion and who did,(did not} · Sigm~mm.of per,On taking acknowledgcmcn ~. · of officer taking aeknowledgcm~t - primed or ~t~nped -. '. ' : T[tl~ ~'~nk .... . , ,, Serial lqumber~ ifany . {~difloat~ o~ Coml~tan~' Holder} . COntractors Stats Certifl'.~tion of Registration N°. . .,~..__~d _ ~i ~ q-.,-o2 ~' . .. Liability !,n, surance Expiration ~t~j. ' · Applioation Approved By ,,JK,-('-. ,! ~ ' , Permit Officer Date: Any change in building plans or specificationS' must be recorded with this office.' Any work not covered above must have a valid permit pti~ to starting. In consideration of granting this permit, the owner and builder'agree to erect this stmclure.in full compliance with the Building and Zoning Codes o! the City of Boynton Beach. ' ' ' NOTE: Thts permit VOID after 180 DAYS uNLEsS the work which it covers has commenced. All Contractors must have valld State Certification or County Competency plus County and City Occupational Licenses prior to obtaining permit. ISSUANCE OF THIS. PERMIT DOES NOT: AUTHORIZE VIOLATION OF DEED RESTRICTIONS .. FEES ARE NOT REFUNDABLE · h~,~[HRDATAtDEVELOPMENT~ORMS.DOC~PERMIT APPLICATION.DOC -ReviSed 6/18/97, 11i4/g7. 12/9B, 6/99, 8/99, 5/00, 8/00 WITH.YOUR LENDER OR AN ATTORNEY BEF..4~R~.RE~DING ·YOUR NOTICE OF COMMENCEMENT. property Owner's Or Agent's signature. ~'/: ~~~'~ ' - : Date WARNING TO OWNER: YOUR FAILURE TO RECOREi:A NOTICE OF COMMENCEMENT.MAY. RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS.TO ~'OUP, PROPE~,TY,.'.IF YOU: iNTE.'~3 ':'O OE}TA!N' F:NAt~CINGi'CON,~ULT ~e Simple TitleHolder's Name /~J~Bt- - ' (If other than owners) ~e Simple Title Holder's ~ddreSs /,J'LAc , , , (If other than owner mtractor's Company (?J~%-~{ ~ ~-g~r~c~J~jC~-c,~ Company Phone # 7.3 -qc >q A . ~ntact person and emergency phone # .~[~ ('~e.~ V_¢e~g ~ . 7,_:~,-~/O~;L~., loading Co. Add.re, ss ' ~ [ ~ , ' CitY ' . . State .......... ~ortgage Lender s Address ~INGLEFAM[LY ~ DUPLEX.g-:. ' MULl'I-FAMILY HOTEL' RETAIL OFFICE ~ [NDUSTEIAL [check one) ESTIMATED VALUE OF CONSTRUCTION $ Applic~lion is hereby required ~o obtain a ~mit to do work and installaik)ns as Indk~ated, 'I c~ify that no-~ or insta{laik)n has commencod prior to tho {ssuanc~ pi a pea'nit and l{~l al{'Work will bo peff~t~d l/) m~oi tho standards o! ~ codes, laws, ru{o.m and moulaflons governing construction in this jurisdiction. I understand ih, at a'separale pemmit must be secured {or ELECTRICAL, PLUMBINO, SIGNS, WELLS, POOLS, FURNACES, BOILERS; HEATERS, TANKS AND. AIR CONDITIONING WORK, ETC. OWNER'S AFFIDAVIT: I certify that all the foregoing Information is. aCCurate'and that all work will be done.in compliance with all applicable codes, laws, rules and regulations governing construction and zoning~ . ~PLICATION # PPLICATION DATE: SETBACKS: LEFT ZONE: · (THIS.SIDE FOR.OFFICE USE ONLY) MASTER,PLAN #; RECEIVED BYe' ' RIGHT 'FRONT. REAR TYPE OF cONSTRUCTION OCCUPANCY TYPE FENCE TYPE ROOF TYPE FLOOD ZONE BASE FLOOD ELEVATION FINISH FLOOR ELEV, (PROPOSED) NUMBER OF ONITS ... PARKING SPACES REQUIRED PARKING SPACES PROVIDED AREA SQUARE FEET (GROSS) AREA SQUARE FEET (NET) #OF STORIES # OF BEDROOMS ADDITIONAL FEE BCAIF 'PARKS FEE PENALTY FEE PUBLIC BLDG.. FEE RADON FEE ROAD IMPACT FEE SCHOOL FEE SEWER FEE WATER FEE FIRE DEPT. FEE OVERTIME FEE SUB-TOTAL REMARKS: SINGLE FEE. Building ' --..,Clearing & Grabbing . D~ainage Electrical ' :. Excavation ' Fire Sprinkler Irrigation.' Landscaping' Paving PavinglDrainag.e Plumbing Roofing Sign Site Ughting .VALUATION FEE REQUIREMENTS for CERTIRCATE OF OCCUPANCY CERTIFICATE OF COMPLEIION FINALS: SITE FIRE DRAINAGE .... PAVING OTHER SITE UGHTING - OTHER AUTHORIZATION for CERTIFICATE OF OCCUPANCY: SIGN FENCE/BUFFER WALL · Date" "' " AUTHORIZATION for CERTIFICA'i:E OF COMPLETION: ' SUB-TOTAL Date TOTAL LESS PLAN' FILING FEE "TOTAL AMOUNT DUE.. RECEIPT NUMBER DATE ISSUED INTERIM SERVICES· FEE CALCULATIONS: Residential: X = Applicable Monthly Fee :. # of Units' Commercial: '~- Divided by 1,000 ' # of Sq. Ft . (mun_ded to ... Nearest. tenth):/· Base Sq. Ft Applicable Monthly Fee Interim Services Fee Base Sq. Ft Rate Interim Services Fee oRIGINAL PERMIT # PROJECT NAME: ........ BuiLDiN~ DIVISION I BUILDING PERMIT REVISION APPLICATION PLEASE PRINT ._e. t4 ~ P /12~o MASTER PLAN ADDRESS: 01-4705 Contractor's Name d.~,.~7-t:a~ t..,W~ /~4::,t,,Oe_k TOTAL ESTIMATED VALUE OF THIS REVISION: DESCRIPTION OF WORK (Please sp~ify in detail what ia being revised from original permi0: BUILDING: ,~ zS_/~i ,t;~- c~ /w ~,~.~ Value of Work: $ ¢LEARING& GRUBBING: Value of Work: $ DRAINAGE: Value of Work: $ ELECTRICAL: Value of Work: $ EXCAVATION: Value of Work: $ FILL: Value of Work: $ FIRE SPRINKLER: Value of Work: $ IRRIGATION: Value of Work: $ LANDSCAPING:, Value of Work $ MECHANICAL: Value ofWork: $ PAVING: Value of Work: $ PAVING/DRAINAGE: Value of Work: $ Value of Work: $ ROOFING: Value of Work: $ Value ofWork: $ SITE LIGHTING: Value of Work: $ I Wish to revise the above referenced' permit to perform the work described herein. I ceftin, that all work will be constructed in conformance with all laws, codes, regulations,"H~, ~on Beach, and I certify that the above info _r?a. tio_n_ is t_ruG a~d cor-wt .... ContractoFs Signature '~' ~-------~Z)~ Date: .~2'"~. ~/'.-~Z.-- [[ .,,~,'~'_'ga~,~ BRIONEYANTALLEY - '" - . II ~;~",~r,'~ MY COMMISSION it CC 888228 8'rATE OF FLORIDA, COUNTY OF PALM BEACH il~!.~' EXPIRE_S.: March 13, 2004 Thefom$oinsim~mm~twuncknowleds~befomn~lhia ,.,~-- ~/Z"--O 2~ (ate)by ,l~s~t,~lt'/I,t~ d~. Signature or pe~on laking acknowledgement "-- ~-,--.,...,-~--- ~ '~ / Name or olil~r taking acknowledgement-typed, printed o~ ~lamped APPLICATION APPROVED BY Permit Officer Date: ISSUANCE OF THIS REVISED P~T DOES NOT AUTHOmZE VIOLATION OF CITY CODES OR D~.ED m~STRICTIO~S FEES FOR RE.VlS__!0NS ARF_.NgT Application # PCN # (Palm Beach County Property Control #) ZONE: (THIS SIDE FOR OFFICE USE ONLY) Master Plan # APPLICATION DATE: RECEIVED BY: TYPE OF CONSTRUCTION OCCUPANCY TYPE FENCE TYPE ROOF TYPE FLOOD ZONE BASE FLOOD ELEVATION FINISH FLOOR ELEV. (PROPOSED). NUMBER OF UNITS PARKING SPACES REQUIRED PARKING SPACES PROVIDED AREA SQUARE FEET (GROSS) AREA SQUARE FEET (NET) NUMBER OF STORIES # OF BEDROOMS REMARKS: ADDITIONAL FEE BCAIF PARKS FEE PENALTY FEE PUBLIC BLDG. FEE RADON FEE ROAD IMPACT FEE SCHOOL FEE SEWER FEE WATER FEE SUB-TOTAL Building. Clearing & Grubbing Drainage Electrical Excavation Fill Fir~: Sprinkler Irrigation Landscaping Mechanical Paving Paving/Drainage Plumbing Roofing Sign Site Lighting VALUE FEE SUB-TOTAL Date stamp marking on the plans Date turned over to Plan Review Cotnpleted By Date Stall' Notilied ,....-----Ia .~P&Z [Eh Plumbing ~ Utilities Police I P.W.. [Parks ForesteL Dev. Dept Date applicant called (-~ ~C~..fi-i''/ to pick-up comments 5- C'"~" ( '"3'~___ Initial I'ermit It l)ate stamp marking on the I~hms Date turned over to Plan Review Review Date ~ Elec. Utilities Completed By Dale Stalt'Notified · tech. I lqumbing Police [ 1'. W, I Date Initials l'arks ] Forester Date applicant called to pick-up comments Initials Review ;. ] Fire Dev. Dept J:~gllRDATA\l)evelol~ment\FORMS.doc\Rovision Applicalion.doo' 12198 bg TOTAL TOTAL AMOUNT DUE RECEIPT NUMBER DATE PERMIT ISSUED Permit # Date stamp marking on the plans Date turned over to Plan Review Completed By l)ate Stall' Notitied IElec' Illcch' ll'luml'inglStructural Utilities Police P.W. ] Parks IDate applicant called to pick-up comments Date Initials [I;orester Initials Review ;. I Vi,'e Dev, I)ept PREPARED 5/24/02, 13:35:12 PAYMENTS DUE RECEIPT CITY OF BOYNTON BEACH PROGRAM BP820L APPLICATION NUMBER: 01-00004705 2400 NE 1ST LN 308 FEE DESCRIPTION AMOUNT DUE ~ 0 1' 4 7 0 5 REVISION/STRUCTURAL TOTAL DUE 35.00 35.00 Please present this receipt to the cashier with full payment. Date: 5/28/82 Total tendered Total oayment Receipt no: 265430 $181.14 $181.!4 CITY OF BOYNTON BEACH DEVELOPMENT DEPARTMENT 100 East Boynton Beach Blvd. P. O. Box 310 Boynton Beach, Florida 33425-0310 ? 01-4705 PLAN REVIEW COMMENTS PLEASE NOTE THAT THE EFFICIENCY BY WHICH YOU RECEIVE YOUR PERMIT DEPENDS ON YOUR RESPONSE TO THE CONTENTS OF THIS DOCUMENT. IT IS RECOMMENDED THAT YOU CAREFULLY READ AND CORRECTLY RESPOND TO ALL ASPECTS OF THIS DOCUMENT. COMMENTS: For permit application number / review: 01-4705 1ST REVISION Project Name or Address: CUSTOMLINE REVIEWED BY: Department and/or Division: BLDG Name of Reviewer: RICK ARMOLD Trade: STRUCT Phone # (561) 742 ext. 6354 Fax # (561) 742-6357 Review Date: 5/24/02 Type of Review: STRUCT COMMENT DISTRIBUTION: Person identified on the application to receive comments: Name VINCENT Phone fl (area code:561) 736-9022 ext. Fax # (area code:561) ~- Date(s) reviewer called: ~::~r&_ ~_"~'~ q'. Person who received the call .~...~ THE FOLLOWING AREA SHALL BE FILLED-IN IN THE PRESENCE eFtA BUlI~ING DIVISlO~'~-% STAFF MEMBER: ~/~~ C~PLANS PICKED UP: ~_men~) recd. by print name and d~t~: Plans/Comments recd. by print name and date: ,,,'"~/,¢~/ /~. '~-~y FILE COPY Page 2 of 2 Plan Review Comments for Permit Application # 014705 1 ST REVISION 01-4705 Your permit application and supporting documentation do not comply with the City of Boynton Beach Code of Ordinances. Prior to receiving a permit to construct or install the requested improvements the plans and documents shall be amended to show compliance with the below listed comments. For questions regarding my review please contact me at the number listed above. If a conference is necessary, please schedule an appointment. Phone calls and appointments are received and scheduled during work days Monday through Friday 9:30 to 10:30 AM and 1:45 to 2:45 PM. Please note that additional comments may be generated following staff review of the amended plans. Timely approval of your project is dependent upon your prompt and correct response to the information provided in this document. PLEASE BRING UPDATED PRODUCT APPROVAL FOR SERIES 7000 AWNING WINDOWS. Seasonshield, Inc. 355 Center Cou~t Venice, FL 34292 Attn: George Fisher AAMA CERTIFICATION PROGRAM NOT~CE OF PRODUCT CERTIFICATION 01-4705 The product described below is hereby approved for listing in the nexl issue of the AAMA Certified Products Directory. The approval is based on successful completion of tests, and the reporting to the Aclministmt~or of ~he ~ of tests, accompanied by related drawings, by an AAMA Accreofted Laboratory. 1, The listing below will be added to the next published AAMA Certified Products Directory. :~ ,~,¢-~A 101j[$. 2-~7 ~ECC.~D CF PRODUCT TES~D ~BEL TA.~~ O~DER NO. ~DE 8E~ES ~ & ~MUM SIZE ~D ~MPANY ~D P~ LO~ON NO. PRODU~ DESC~P~ON ~W~ ~1 ~(~~ 4~x~ 4'4'x 1~ vW~ 2. This Cerliflcation will expire Ju1~14. 2003 and mquires validatlon until then by continued listing in the current issue of the AAMA Certification Program D~eclmy. 3. Product Tesmd and Report by: National Calitled Testing_ Laboratories (A) Rep(xt No.: NCTL-210-2231-1 (B) Dae of Report: .~ (C) Date of Receipt of Repon by Administrator:. Ser~tember 9. 1999 NOTE: PLF_,~E REVIEW, AND ADVISE ALI IMMEDIATELY IF DATA. AS SHOWN, NEEDS CORRECTION. .~.~ate: __8~-~X_ embe~ 29. 1999 cc: AAMA JGS:td Approved for Ceffif'~,ation: NATIONAL CERTIFIED TESTING LABORATORIES tm-3, v 6 t464 GEMINI BOULEVARD, ORLANDO, FLORIDA 32837 PHONE (407) 240-1356 · FAX [407) 240-8882 01..t7 05 STRUC~..U.RAL PERFORMANCE TE~T REP. ORT, ~CL!E,NT.: Season.shield Incorporated 355 Center Court Ver~ice, FL 34'2.92 TEST S_PEC. I~EN: Se~:.~[~:Id [t:~.;c/,.c_~ 'J.; _ :. i~: ~. Pr]me Window. (AP-R40) (53 x 72) TI~ST SPECIFICATION: AAMA/NWWDA 1011I.S. 2-97,"Voluntar)' 5pecifica::,oas t'or Asum'r:~a, VL'~yl ~P'v':~) and Wood Windows and Glass Doors." TES.? SPEC[MEN DESCRIPTION ~:. The specimen tested was a tour (4) vent aluminum a~aming aluminum prime window measuring 4'~- 1/8" wide by ?2" high overall. The vents measured 4'4-1/8" wide by 1'~-3/8" high. The frame and vent members were no[thermally broken. One ATW crank mechanism mounted to the bonom of the fi-amc stile with tin'ce (3) screws operated a standard awning window slide bar hinge and locking system. One operator slot cover plate was fastened with t~vo (2) screws at the opposite stile employing the operator. The vent comers were of single interlocking tab coped comer constructio~. The frame comers were or'double screw (# 8 x $t8") pan head coped comer construction. I~N~TALLATIQN, EASTENERS: The frame was mounted to the test buck using sixteen (16) (# $ x 1-1/4") pan head screws. ~GL, AZIN.G: All vents were exterior glazed using !18" thick double strength annealed glass with an adhesive bedding and an aluminum glazing bead. The exterior glazing perimeter employed a silicone cap bead. WEATHERSTRI~,: A single strip of bulb vinyl weathers[tip was located at the vent's bottom rails, head, sill and each ,jamb. W..~: No weeps employed. I~TERIOR & EXTERIOR SURFACE FINISH: White painted alum~um. PROFE$SIONALS IN THE SCIENCE OF TESTING RECEIVED MAY ? 2002 ~tLE COpy RECEIVED JAN 2 2 2002 Scasonshield Incorpor. ated -2- NCTL-210-225 I-! SEALANT: lVlain frame members were sealed with a silicone sealant. 01'4705 INSECT SCRi~EN: An insect screen measuring 4'0-tiS" wide by $'9" high ,.vas of mitered type comer construction with staked-ia-place aluminum corner keys. The screen employed fiberglass mesh cloth with a hollow vinyl spline and two pull tabs. P:&RAGI~spH NO; TITLE OF TEST bl ~ASURED _ALLO_WED 2.1.2 Air Infiltration ! .:57 psf(25 mph) 0.09 CFM/FT 0.30 CFM/FT 2.1.3 Water Resistance -($.0 OPH/FT:) ~ir':. FaW' NO Entry 2,l.4.2 Uniform Load Structural 22.5 psrexterior 0.03 I" 0.216" 22.~ psf interior 0.03 $" 0.216" 2.2.4.5.1 Hardware Load Test Meets as stated 4.3 4.4,2 OPTIONAL PERFORMA_N .CE Water Resistance - (5.0 (3 WTP =, 8.25 psf No Entry Uniform Load Structural 60.0 psf exterior 0.089" 60.0 psfinterior O. 103" NO Ent~ 0.216" 0.216" TEST COMPLETED: 07-14-99 This test specimen meets the performance criteria level of AP-R40 (53 x '/2) or'the AAMA/NWWDA 101/I.S. 2-97 · specification. Detailed drawings were available for laboratory records and compared to the test specimen at the time of ~his report. A copy olr this report a:ong with representative sections of the test specimen will be retained by NCTL for a period four (4) years, 'l'h.~ results obtained apply only to the specimen tested. blEL/{d ~IFIED TESTING ion Manager RECEIVED M,¥ zoo RECEIVED FILE COPY BU{L.n. ING DI¥1~$10N JAN 2 2 2002 BUILDING I 01-4705 FASTEN'ER LOCAT!ON~ t"4" TEST BUCK /. ///.- //// . //// - 13-314~ 1~-~/4" 13-3/4' i 3-314" Olqxts~e Jamb ldenlkal I 'fh~ test s4~ecinu~n wa~ mountml tn Ihe trot budt usin~ sixleen (16) (~x 14/4')~ ~ ~A 1Ol~ ~ NA~ C~D ~ ~ANY: bm~ ~~ S~: "~A~.s~ (6) v~ ~ ~T~ ~-1~ REC~[IVEORECEIVED ~k¥ ~ ~ 2002 JAN 2 ? 2002 ..... BUILDING D~VtS~ON FILE CoPy ~U[OlNG DIVISION I : ." "' ' I ! ! ; _' ! " !F_.CEIVED MAY 2 :~ 2002 jAN 2 2. 2002 {::|LE cOPY BUILDING DIVISION ~UiLOING OiVISION MIAMI-i)ADE ¢OlhNTY. FLORIDA - 4.7' 0 5,,,ET O-O^oE F,-. GLER UILO, G PRODUCT CONTROL NOTICE OF ACCEPTANCE L;nvson Industries, 8501 NW 90 St 5'!cdlcv FL 33166 BUll. DING CODE CO.M?LIANCE OFFICE METRO-DADE FLAGLER BUILDING 140 WEST FLAGLER STREET. SUITE 1603 MIAMI. FLORIDA 33 ] 30-1563 (305)'375-290[ FAX (305) 375-290S CO.'~FI~CI'OR LICENSING SECTION (JO5) 375-2527 FAX (305~ 375-255~ CONTRACTOR £NFORCEMENT SECTION (305) 375-2966 FAX {305) 375.29~S Your application Ibr Product Approval of: Series 1161 Ahtmin um Awning Window under Chapter 8 of the Code of Miami-Dade C~nty governing th~ use of Alternate Materials and Types of Construction, and completely described herein, has been recommended tbr acceptance by the Miami-Dade County Building Code Compliance Office (BCCO) under the conditions spccilied herein. product or material at anytime l~om ajobsite or manufScturer's plant ~br quality control testing. If this product or material f~ils to perfgrm in the approved manner, BCCO may revoke, moditg', or the use of such product or material immediately. BCCO .reserves the right to revoke this approval, if determined BCCO that this product or material [~ils to meet the requirements o~'the South Flor/da Building Code. Thc expense of such testing will be incurred by the manuthcturer. Acceptance No.: 00-0519.03 Expires:liS/2812003 Raul R. odriguez/d' - Chief Product Control Division Tills IS THE COVERSIll,.ET, SEE ADDITIONAL PAGES F()R SI'ECIFIC AND GENI.:IL-\I. CON I) ll"IONS BUILDING CODE & I'ROI)UCT REVIEW COM3IITTEE This application lbr Product Approval has been reviexved by the BCCO and approved by the Building Code and Product Review Committee to be used in Dade County, Florida t, nder thc conditions set lbrth above. Apl)roved: 07/20/2001) i of 3 RECZIVEO HAY 2 2002 FILE COPY BUH..DING DIVISION ~'t¢)tlleOill2t,: ~lt~D'/t'.',v*x''' ])'tliid;.n~c ¥,5. c,~{ 1'~ ' t' 11 L:m'son Industries. Inc. 01-4705 ACCEPTANCE No.: APPROVED : 00-0519.03 JUL 2 0 Z000 1 EXPIRES : Auo~ust.8. 2003 NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS approves an aluminum awning window, as described in Section 2 of this Notice of Acceptance, designed to comply with thc South Florida Building Code (SFBC), 1994 Edition for Miami-Dndc County, for the locations where the pressure rcquiremchts, as determined by SFBC Chapter '~" __,, do not exceed the Design Pressure Raling values indicated in the approved draxvings. P?.'ODI'CT DESCRIPTION ' -Ehe Series i16i Ahnninum A~vaing Window and /ts con.tponenrs shall be constructed in strict compliance with the following documents: Drawing No W96-44; titled "Series-1161 Awning Type Window," Sheets 1 thru 3 of 3, dated ll/21/96, with revision "B" dated 5/15/00, signed and sealed by Humayoun Farooq, P.E., bea"i'ing the Miami,-Dade County Product Control approval stamp with the Notice of Acceptance number and approval date by the Miami-Dade County Product Control Division. These documents shall hereinafter be referred to as the approved drawings. 3. LIMITATIONS 3.1 This approval applies to single unit applications, as shown approved draxvings. 3.2 For Design Pressure Rating vs. Window Size, see Comparative Analysis Tables in approved drawings. 4. INSTALLATION ' 4.1 The aluminum awning window and its components shall be installed in strict compliance with thc approved drawings. 4.2 Hurricane protection system (shutters): the installation of this unit will require a hurricane protection system. 5. LABELING 5.1 Each unit shall bear a permanent label ,.vith the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved". o BUILDING PERMIT REQUIREMENTS Application for building permit shall be accompanied by copies of thc folloxving: 6.1.I This Notice of Acceptance 6.1.2 Duplicate copies &the approved drawings, as identified in Scction 2 of this Notice of AcccptanccT'clearly markcd to show thc components selected for thc proposed installation. 6.1.3 Any other documents required by the Building Official or thc So_u~.F_,,Lorida Building Code (S~BC) in order to properly evaluate thc _ ,'vlanuc/ellc~2~ l~roducLL>0ntrol Exami::c: ~, [r l,---~- ' Industries. Inc. 01.-47 05 ACCEPTANCE No.: APPROVED : JUL 2 0 2000 EXPIRES : Auo~nst 28. 2003 NOTICE OF ACCEPTANCE: STANDARD CONDITIONS 1. Rer:e,.val of this Acceptance (approval) shall be considered after a renewal application has been filed no older than eight (8) years. 2. Any and all approved products shall be pe~anendy labele8 with the manufacturer's name, city, state, and the following statement: "Miami-Dade County Product ~ontrol Approved", or as specifically stated in the specific conditions of this Acceptance. " - : ........ "no~ be considered a) There has been a change in the South Florida Building Code affecting the evaluation of this produc~ and the product is not in compliance with the code changes; b) The product is no longer the same product (identical) as the one originally approved; e) If the Acceptance holder has not complied with all the requirements of this acceptance, including the cogect installation of the producq d) The engineer who originally prepared, signed and sealed the required documentation initially submi=ed is no longer practicing the engineering profession. 4. Any revision or change in the materials, use, angor manufacture of the product or process shall automatically be cause for te~ination of this Acceptance, unless prior wriaen approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5. Any of the following shall also be grounds for removal of this Acceptance: a) Unsatisfacto~ perfo~ance of this produci or process. b) Misuse of this Acceptance as an endorsement of any product, for sales, adve~ising or any other pu~ose. o The Notice of Acceptance number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the.job site at all time. The engineer need not reseal the copies. Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance. - This Notice of .A. cceptancc consists of pages I, 2 and this last pa,: . I A¥ 2. 2002 END OF THIS ACCEPTANCE - ~ - ManueJ~ere~, P.E. Product C~t Exam Product ~r~l Division ~ METRO-DADE FLAGLE'R BUILD[N --- 01-4705 PRODUCT CONTROL NOTICE OF ACCEPTANCE Lawson Industries, Inc. 8501 N3,V 90 Street Medley ,FL 33166 You- ' ~tion for Notice. of Acc~..ptance CNO.'k). f',fi_. eming BUILDING CODE COMPLIANCE OFFIC METRO-DADE FLAGLER BUILDI%' 140 WEST FLAGLER STREET. SUITE 16C MIAMI. FLORIDA 33130-156 (305) 375-2901 FAX (305) 375-2913 CONq'RACTOR LICENSING SECTIO (305) 375-2527 FAX (305) 375-2!5 CONTRACTOR ENFORCEMENT DIViSIO (305) 375-2966 FAX (305) 375-29(~ PRODUCT CONTROL DIViSIO; (305) 375-2902 FAX (305) 372-633 the use of Alternate Materials and Types of Construction, and completely described herein, has been recommended for acceptance by the Miami-Dade County Building Code Compliance Office (BCCO) under the conditions specified herein. Th~s NOA shall not be vaI~d alter the expiration date stated below. BCCO reserves the right to secure thi., product or material at ~-:y time from ~ jobsite, or m.~u£acr'~er's pi~:: ~cr qua!ky con~r,ol testing. If thi.~ product or material fails to perform in the approved manner, BCCO may revoke, modify, or suspend the use of such product or material immediately. BCCO reserves the right to revoke tkis approval, if it L, determined by BCCO that this produc{ or material fails t° meet the requirements of the South Florida 'Building Code. The expense of such testing will be incurred by the manufacturer. ACCEPTANCE NO.: 01-1106.03 EXPIRES: 12/10/2006 Ra'.,i Rodriguez Chief Product Control Divi§ion THIS IS THE COVERS1TEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE & PRODUCT REVIEW COMMITTEE This application for Product Approval has been reviewed by the BCCO and approved by the Building Code and Product Review Committee to be used in Miami-Dade County, Florida under the conditions set forth above. Francisco J. Quintana, R.A. Director Miam i-Dade County. APPROVED: 11/29/200I Building Code Compliance Office. Mnmo~',~- I-t~n'//www.buJldJri~q'n(lcoll|iltc.co rtl Lawson Industries. Inc. 01- 'f ACCEPTANCE No.: 01-1106. NOTICE OF ACCEPTANCE: APPROVED: November 29, 2~___0_0 EXPIRES: December I0, 20____d STANDARD CONDITIONS 1. Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the original submitted documentation, including test supporting data, engineering documents, are no older than eight (8) years. 2. Any and all approved products shall be permanently labeled with the manufacturer's name, city, state, and the following statement: 'Miami-Dade County Product Control Approved", or as specifically stated in the specific conditions of this Acceptance. 3. Renewals of Acceptance will not be considered if: a) Tr'~er~ h:..~ been a change in the South Florida Building Code affecting the evaluation of this product and the product is not in compliance with the code changes; b) The product is no longer the s,,ame product (identical) as the one originally approved; c) If the Acceptance holder has not complied with all the requirements of this acceptance, including the correct installation of the product; d) The engineer who originally prepared, signed and sealed the required documentation initially submitted is no longer practicing the engineering profession. 4. Any revision or change.in the materials, use, and/or manufactm-e of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5. Any of the following shall also be grounds for removal of this Acceptance: a) Unsatisfactory performance of this product or process. b) Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any other purpose. 6. The Notice of Acceptance number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 7. A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at all time. The engineer need not reseal the copies. 8. Failure to comply with any section of this Acceptance shall he cause for termination and removal of Acceptance. 9. This Notice of Acceptance consists of pages I, 2 and this last page 3. Raul Rodriguez. CSief Product Control Division 3 PREPARED 12/03/01, 15:48:2~ 0 1 ' 47 0~PAYMENTS DUE RECEIPT CITY OF BOYNTON BEACH · PROGRAM BP820L APPLICATION NUMBER: 01-00004705 2400 NE 1ST LN 308 FEE DESCRIPTION AMOUNT DUE BUILDING PERMIT 35.00 .TOTAL DUE 35.00 Please present this receipt to the cashier with full payment. ope_ r: floHc~YOG ~ate: 12/64/01 B1 Receipt no: 66659 Total tendered $35.66 Total payaent $35.66 01-4705 MIAMI-DAD£ COUNTY, Ft. ORIDA IViETRO.DADIZ FL^GLER BUILDING BUILDING CODE COMPLIANCE OFFICE PROI)UCT CONTROL NOTICE OF ACCEPTANCE Security Windows ii Doors 5100 NW 72 Ave. Miami FL 33166 Your application for Producl Approval of: Series' 7000 Aluminum Awning Window (2 Wide) METRO-I)AD£ FLAGLER ~JUILDING 140 WEST PLAGLER STRE£T. SUITE 1603 MIAMi. FLORIDA 33130-1563 (305) 375-2901 FAX (305) 3'/~-2906 CONTRACTOR LICENSING SECTION (30~) 375-'2'.527 lAX (305) 375-2558 CONTRACTOR £NIrORCEMENT SECTION (305) 375-296d FAX (:!05) 375.2908 PRODUCT CONTROL DI¥1SION (305) 375.3902 FAX (305) 372-6339 under Cliapter 8 of the Code of Miami-Dade County governing the use of Altcmat¢ Materials and Types of Con.~truction, and completely described herein, has been rccormncnded for acceptance by thc Miami-Dare County Building Code Compliance Office (BCCO) under the condilions specified herein. Thi,~ approval shall not be valid after the expiration date stated below. BCCO reserves the right to secure this product or material at nqyljme from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, BCCO may revoke, modify, or suspend the use of such product or material immediately. BCCO reserves thc right to revoke this approval, if it is deternfined BCCO that this product or malcrial fails to meet the requiremcms of thc South Florida Building Cod~. The expense of such testing will be incurred by the manufacturer. Act.¢ptance No.: 99-0301.03 Expires:03/01/2002 Chief Product Control Division THIS IS THE COVERSItEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE & PRODUCT REVIEW COMMITTEE This application for Product Approval has becn reviewed by thc BCCO attd approved by the Building Code and Product Review Committee to be used in Dude County, Florida under the conditions set forth above. Approved: 05/06/1999 1 .of 3 L~.ra-n~i~¢o 1~ Quintana, R.A. Director Miami-Dare County Building Code Compliance Office SHEET OF PERMIT SEI' DO NOT REMOVE tnternet mail address: poslma.~ter~huildingcodeonliee.¢om ~ Home page :ih ~ t p :~twww. buildiag~adeonlifle;com S._ccuri/¥ _A.].u.t__njnum Window.~. ACCEPTANCE No.: Al'PROVED : 99-0301.03 EXPIRES NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS SCOPE This renews Notice of Acceptance No. 95-0929.25, which was issued on March 1, 1996. This approves an aluminum awning window, as dcscrlbcd in Section 2 of this Notice of Acceptance, designed to comply with the South Florida Building Code (SFBC), 1994 Edition for Miami-Dade County, lbr the locations where the pressure requirements, as determined by SFBC Chapter 23, do not exceed the Design Pressure Rating values indicated in the approved drawings. PRODUCT DESCRIPTION Thc Series 7000 Aluminum Awning Window (2 wide) and its components shall be conslructed in strict complim~¢e with the following documents: Drawing No W99-11, titled" Series-7000 Aluminum Awning Window," Sheets I through 4 0£4, dated February 24, I999, signed and sealed by 1.1umayoun Farooq, P.E., bearing the Miami-Dade County Product Control approval stamp with the Notice of Acceptance number and approval date by the Miami-Dade County Product Control Division. These documents shall hereinafter be referred to as the approved drawings, 3, LIMITATIONS 3.1 This approval applies to single trait applications, as shown approved drawings. 4. INSTALI,ATION 4.1 The alunfinum awning window and its components shall bt: instalted in strict compliance with the approved drawings. 4.2 Hurricane protection system (shutters): the installation of this unit wi!! req,glr_e~ a hurricane protection system. 5. LABELING S.l Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved". I~UILDING'PERMIT REQUIREMENTS Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance 6.1.2 Duplicate copies of the approved drawings, as identified in Section 2 of this Notice of Acceptance, clearly marked to show the components selected for the proposed installation. 6.1.3 Any other documents required by the Building Official or the South Florida Building Code (SFBC) in order to properly evaluate the installation of this system. SHEET OF PERfv4IT SET DO NOT REn n /r 2 of 3 Manug~ Perez, P.E. Product Co,roi)Examiner Prodt~.9.Btrol Division 01-4705 ~_(?..c..~,i.,r_i,t~y A I u nm i n u nm. ACCEPTANCE No.: 99-0301.03 APPROVED : MAY 0 6 1999 EXPIRES : Marclt 1, 2002 ~OTICI~i OF ACCEPTANCE: STANDARD CONDITIONS 1, Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the original submitted documentation, including test supporting dala, engineering documents, arc no older than eight (8) years. 2. Any and all approved products shall bc permanently labeled witli tile manufacturer's name, city, state, and the following statement: "Miami-Dude County Product Comrol Approved", or as specifically staled in the specific conditions of this Acceptance, 3, Renewals of Acceptance will not be considered if: a) There has bee0 a change in the South Florida Building Code affecting the evaluation of this product and th~ product is not in compliance with the code changes; b) Thc product is'no longer the same product (identical) as the one originally approved; e) If the Acceptance holder has not complied with all the requirements of tiffs acceptance, including the correct installation of the product; d) Thc engineer who originally prepared, signed and sealed the required documentation initially submitted is no longer practicing thc engineering profession. 4. Any revision or change in thc materials, use, and/or manufacture of thc product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing ora revision application with appropriate fee) and granted by this office. $. Any of the following shall also be grounds for removal of this Acceptance: a) Unsatlsfaetory performm~ce of this product or process. b) Misuse of this Acceptance as an endorsement of any product, for sales, advcrlising or any other purpose. 6. The Noliee of Acceptance number preceded by the words Miami-Dare County, Florida, and followed by thc expiration date may be displayed in advertising literature. If m~y portion of tile Notice of Acceptance is displayed, then it shall be done in its entirety. 7. A ~opy of this Acceptance as well as approved drawings and other documents, where it applies, shall be provided to the user by the manufacturer or it~ distributors and shall be available for inspection at thc job site at all time. The engineer need not rcseal thc copies. g. l:ailur¢ to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance. This Notice of Acceptance consists of pages 1,2 and this last page 3. END OF THIS ACCEPTANCE Manue~'Pcrez, P.E. Product C~i'tro.~'Examiner Produc~7.on6o} Division SHEET OF PERMIT SET DO NOT REMOVE 01'470~ SHEET OF PERMIT SET DO NOT REMOVE ? <.. ,~§. 01"4705 SHEET OF PERMIT SET DO NOT REMOVE ® LC'× ) ,.~(~ ............. $ I ~ tg) ~ I ~' ' - ............... £NGINCCIt$, Pt..MiNERS ~ PROD~I Il A =/L::~;.~2,.,~N-I .-~1, ~A~, FL ~3 66 ilL ~ (~) '"-' ~ '~ 01-~705 $'"-iEET OF PERNilT SET DO NOT REMOVE SHEET OF Pi~!Rii,,.~IT SET DO NOT REMOVE 0l..4705 (Vdldalor I Op~lflOfl~ Ad~ifll$~rllof). AAiVlA -- 0 1 - 4 7 0 5 CEFITIFICATION PROGRAM NOTICE OF PRODUCT CERTIFICATION Seasonshield, Inc. 355 Center Court Venice, FL 34292 Attn: George Fisher The product described below is hereby approved ~of listing in the nexl Issue of the AAMA Certified Products Directory. The approval is based on successful completion Of tests, arKI the reporting to the Administrator of the ~ o~ t~Ms. accompanied by related drawings, by an AA. MA Accreclitecl Labor;amy. 1, The listing below will I~ added to the hex1 published Aa, UA Ce~dfied Products Director/. SPEC;FICATION RECORD OF PRODUCT TESTED ~ 101/[,6. 2-97 LABEL TA-R4OO3X72 ORDER NO. CODE SERIES MODEL & MAXIMUM SIZE TESTED COMPANY AND PLANT LOC^~ON NO. ~RODUCT DESCR~PT~)N , 3~ C~ C4)ud GSD-1 (AL)(4-VENT)(OG) 4~J' x ~ 4'4' v 11;' By Req~ 2. ~ C~liticatio~ will expire July 14. 2003 and requires validation until ~ by continued listing in the current b~_~e of the AAMA Certification Program Directmy. 3. Product Temed and Report by: National Certified Testing Latxwatorles (A) Repro1 No.: NOTL.210-2231-1 Date ol Report: (C) Date Of ReceiiX o~ Report by Administrator: NOTE: PLEASE REVIEW, AND ADVISE ALI IMMEDIATELY IF DATA, AS SHOWN, NEEDS CORRECTION. .~._~ate: _8_e_~mber 29. 1999 cc:. AAMA JGS:td ~eptember 9. 1999_ Approved for Certification: RECEIVE CORRECTED FILE COPY BUILDING 01-47 05 -NATIONAL CERTIFIED TESTING LABORATORIES 1484 GEMINI BOULEVARD · ORLANDO, FLORIDA 32837 PHONE (407) 240-1356 · FAX (407) 240-8882 STRUCTURAL_. PERFORMANCI~ TEST_ REPORT REPORT NO.: NCTL-210-223 i-! TEST DATE: 07-14-99 REPORT DATE: 05-13-99 EXPIRATION DATE: 05-I $-03 .C~_IENT: Seasonshield Incorporated 355 Center Court Venice, FL 34292 TEST SPECIMEN: Seasonshield [ncorporated's Series "300 ATW" Four (4) Vent Narrow Awning Aluminum Prime Window. (AP-R40) (53 x 72) TI[/;ST .S.PECIFICATION: AAMA/NWWDA 10 I/i.S. 2-g7, "Voluntacy Specifications for Aluminum, Vinyl (PVC) and Wood Windows and Glass Doors." TEST SPECIMEN DESCRIPTION ~EN_ ERAS:. The specimen tested was a t'our (4) vent aluminum awning aluminum prime window measuring 4'5- 118" wide by '/2" high overall The vents measured 4'4-1/$" wide by 1':5-3/8" high. The fr4me and vent members were not thermally broken. One ^TW crank mechanism mounted to the botlom of'the flame stile with three {3) screws operated a standard awning window slide bar hinge and locking system. One operator slot cover plate was fastened with t~vo (2) screws at the opposite stile employing the operator. The vent comers were of single interlocking tab coped comer construction. The frame comers were of double screw (~ 8 x $/8') pan head coped comer construction. INgTALLATIQN FASTENERS,: The frame was mounted to the test buck using sixteen (16) (# 8 x i-I/4") pan head screws. ~GLAZ!NG: All vents were exterior glazed using 1/8" thick double strength annealed glass with an adhesive bedding and an aluminum glazing bead. The exterior glazing perimeter employed a silicone cap bead. WE.ATH_ ERSTRIP: A single strip of bulb vinyl weatherstfip was located at the vent's bottom rails, head, sill and each jamb. WEEPS: No weeps employed. INTI~RIOR & EXTERIOR SURFACE FINISH: White painted alum~um. CORRECTED JAN FILE COp BUILDIN~ Seasonshield Ineorpor. ated -2- NCTL-210-223 I-I ~;EALANT: Main frame members were sealed with a silicone sealant. INSECT SCREEN: An insect screen measuring 4'0-1/8" wide by 5'9" high was of mitered t~pe comer construction with staked-in-place aluminum corner keys. The screen employed fiberglass mesh cloth with a ho{low vinyl spline and two pull tabs. TEST RESULTS PARAGRAPH NO. TITLE OF ]'EST ]M[ASURED ALLOWED 2.1.2 Air Infiltration 1.57 psf(25 mph) 0.09 CFM/FT 0.30 CFNOTT 2. i.3 Water Resistance - (5.0 GPH/FT") WTP -- 2.86 psf No Entry No Entry 2. !.4.2 UnifOrm Load Structural 22.5 psfexterior 0.031" 0.216" 22.5 psf interior 0.035" 0.216" 2.2.4.5.1 Hardware Load Test Meets as stated 4.3 OPTIONAL PERFORMANCE Water Resistance - (5.0 GPH/FT:) WTP- 8.25 psf No Entry NO Entry 4.4.2 Uniform Load Structural 60.0 psf exterior 0.089" 0.216" 60.0 psf interior 0.103" 0.216" TEST COMPLETED: 07-14-99 This test specimen meets the performance criteria level of AP-R40 (53 x 72) of the AAMA/NWWDA 101/I.S. 2-97 · specification. Detailed drawings were available for laboratory records and compared to the test specimen at the time of this report.. A copy of this report a:ong with representative sections of the test specimen will be retained by NCTL for a period of four (4) yeats. 'frn~ results obtained apply only to the specimen tested. MEL/Id ~IFIED /~ion Manager TESTING RECEIVED FILE COPy ~UILDIN(~ DIVI.RION Oct-O6-gg 02:Z7P P.04 6'4-314" FASTENER LOCATIONS ............ 13-3~ ' 13-31, / /// --t- ...... 13-3/, //// ----[-- 13-~/, //// -~- .... /// / --4-- 0/-4705 TEST BUCK Opposite Jmb ldenmt RECEIVED JAN 2 ;: 2002 FILE COPY I =! I ~ I : : ! : FILE COP'~ :EIVED