REVIEW COMMENTS
M E M 0 RAN DUM
January 31, 1989
TO:
FINANCE DEPT.
FROM:
JAMES J. GOLDEN, SENIOR CITY PLANNER
PROCESSING OF CHECKS
RE:
Attached please find the following checks:
Dale Construction Corp., Lake Worth Christian School, Height
Exception, in the amount of $125.00;
Jean Robert Joseph & Edna Joseph, Environmental Review Permit, in
the amount of $200.00;
Laura Leigh Martin and Lawton M. Martin, Environmental Review
Permit, in the amount of $150.00;
A&A Investments, Variance Payment, in the amount of $400.00;
Organi-Grow, Inc, Environmental Review Permit, in the amount of
$200.00;
T.B. Gietz Construction, Inc., Eastgate II at Hunters Run, Site
Plan Modification, in the ~mount of $200.00;
~ida Construction Planners Corp, Safe Keeping Self Storage,
Site Plan Modification, the amount of $200.00;
Summit Assoc., Hunters Run, Essex, Site Plan Modification, in the
amount of $200.00;
Summit Assoc., Hunters Run, Bristol, Site Plan Modification, in
the amount of $200.00;
Summit Assoc., Hunters Run, Windsor, Site Plan, in the amount of
$350.00;
Estates at Hunters Run, Site Plan Modification, in the amount of
$200.00;
Eastgate at Hunters Run, Eastgate I, Site Plan Modification, in
the amount of $200.00;
High Ridge Country Club, Inc., Site Plan Modification, in the
amount of $200.00;
Universal Medical Bldg., Bethesda Medical Office Bldg., Site Plan
Modification, in the amount of $200.00;
Account numbers for deposit are indicated on the back of the
checks.
kii-v~
J ES ;d. GOLDEN
JJG:ro
Attachments
cc Central File
M E M 0 RAN DUM
September 8, 1988
TO: CHAIRMAN AND MEMBERS
PLANNING AND ZONING BOARD
FROM: CARMEN A. ANNUNZIATO, PLANNING DIRECTOR
RE: SAFE-KEEPING SELF STORAGE-SITE PLAN
STAFF COMMENTS
Please be advised of the following Planning Department comments
in connection with the above-referenced site plan request:
1. Right-of-way for Congress Avenue to be dedicated to
Palm Beach County sixty (60) feet from centerline,
consistent with the thoroughfare Right-of-Way Protection
Map. The dedication is to occur within forty-five (45)
days of site plan approval.
2. As per Appendix A, Sec. 11-H.16.f(5), 145 parking
spaces are needed for this project based upon one
space per 800 square feet of gross floor area, but
not less than two (2) spaces per rental unit of
500 square feet of gross floor area or greater. The
applicant has provided 143 spaces. Parking space and
square footage changes should be reflected on the
application and sheet A-1.
3. A dumpster enclosure detail is needed showing a
minimum 10' by 10' concrete slab with a six 6' high
CBS masonry wall on three (3) sides to match building.
A minimum ten (10) foot opening is required.
4. Elevations do not indicate colors to be used.
5. No lighting plan has been provided showing light curves,
one footcandle per square foot minimum illumination level,
photocell activation, wattage, energy efficient light
source, manufacturer's specification, and pole mounting
detail.
6. The small parking lot along Congress Avenue does not
conform to parking lot and landscape regulations. If
parking spaces are to be 9 feet by 16 feet, the
landscape strip abutting such spaces will need to
be a minimum of 4 1/2 feet along adjacent property lines
to credit a 2 foot overhang.
7. The parking spaces on the west side of building "c" need
to be 9 feet by 18 feet with wheelstops. There is no
room for a 2 foot overhang credit.
8. The parking spaces in the rear of the site along the north
and south property lines are only 9 feet by 16 feet. The
landscape strip abutting such spaces will need to be a
minimum of 4 1/2 feet along adjacent property lines to
credit a two (2) foot overhang.
~ .,J.. d:-~1Tt.}t;.~II. Jl..
CARMEN S. ANNUNZIATO '
CSA:ro
cc Central File
MEMOR:A'N:DU^_
TO
Carmen Annunziato
Planning Director
DAT~
September 7, 1988
FILl'
F"OM
Don Jaeger
Building Department
Site Development
SU8nCT SITE PLAN APPROVAL:
SAFE KEEPING SELF STORAGE
As a condition of site plan approval, the following comments
should be addressed in the related documents by the applicant:
1. The applicant is requesting approval for a 186 sq. ft. free-
standing sign. The Sign Ordinance restricts a free-standing
sign in an M-l Industrial District to 32 sq. ft. unless
otherwise approved by the Planning and Zoning Board,
Community Appearance Board and the City Commission.
2. Parking lot striping must comply with the Parking Lot
Ordinance. Parking stalls must be a minimum of 18 feet in
length.
3. The Zoning Ordinance prohibits residences in M-l Industrial
zones.
4. Trees must be a mlnlmum of 8 feet in height at the time
of planting. Hedges along the right-of-way must be a
minimum of 36 inches in height at the time of planting.
5. Construction details on the dumpster enclosure must be
provided.
6. The structures must comply with Table 400 and Chapter 6
of the Standard Building Code.
7. Handicapped accessibility must be provided to all structures.
8. Light poles must be designed to withstand 120 m.p.h. windload
in conformance with Chapter 12 of the Standard Building Code.
9. South Florida Water Management District approval is required.
10. A turn-out permit from the Palm Beach County Engineering
Department is required.
11. Section A-A of sheet 4 of 6 complies with code. This section
differs from the dimensions shown on sheet 3 of 6 (the
horizontal control drawing).
M E M 0 RAN DUM
September 7, 1988
TO: Mr. Jim Golden
Senior City Planner
FROM: Tom Clark
City Engineer
RE: Site Plans, Congress Avenue Mini Warehouse (Safe Keeping
Self Storage)
COMMENTS:
1. Inlet grates to be bicycle proof.
2. See Bill Flushing's memo of August 25, 1988.
~C(~
Tom Clark
TAC/ck
attach
To:
MEMORANDUM
From:
Date:
Subject:
Carmen Annunziato, Planning Directo~~
John A. Guidry, Director of Utilities~
September 7, 1988
TRB Review - Safe Keeping Self Storage - Site Plan
We can approve this project subject to the following:
1. Provide the developable parcel to the east and south of
the property with water and sewer stubs in easements.
The sewer must be extended to the northeast property
corner at maximum depth, and terminate in a manhole.
2.
3.
4.
5.
6.
7.
cmd
be:
Relocate the dumpster so as to allow access to the sewer
manhole in the rear of the building.
Extend the paved area to manholes 2 and 3, for access by
heavy maintenance vehicles. Provide access ramps as
necessary.
Sampling points are not permitted directly off of
hydrants.
Provide fire flow calculations.
Show all utilities within easements.
The water service must be of type "K" copper.
Peter Mazzella
MEMOR'A'N.'DUI\.-
TO
Mr. J. Goldon
DATE
07 September 88
"ILI:
FltOM
Lt. Dale S. Hammack
SUBJECT
Safekeeping Self Storage
As per our discussion at the Technical Review Board meeting of 06 September 1988,
I am recommending the following:
1. Need lighting details,
2. Details of directional arrow striping on travel lanes,
3. Comply with Construction Ordinance Section 7.
--hVd/ ~
~ /Dale S. Hammack
DSH/lav
r ' (6") lettering, numerals or combination, in a conspicuous
manner and of diverse coloration.
(11) Parking Identification. Assigned parking spaces
shall not be identified to coincide with room number, name
or unit address.
Section 7. Construction Sites
The provisions of this section shall apply to any sites
proposed for construction that are required to obtain
Commission approval. "
(1) Security measures at a construction site are
determined after a security survey is conducted using the
following procedures.
(a) One staging area, to store equipment and park
machinery, must be fenced.
(b) The staging area must be visible from an
aacessible roadway to allow effective pOlice patrol.
(c) Lighting must be provided to allo\>l complete
visibility to the area.
- (d) Padlock all storage trailers and park within
staging area.
~ (2) Items that must be discussed during a security
survey with the Crime Prevention Bureau.
(a) The establishment and progressive evaluation
of a sepurity budget.
. (b) The proper posting of the property.,
(c) The proper storage and marking of machinery
and tools.
(d) The methods of employee identification and
active site security methods.
Section 8: That all ordinances or parts of ordinances
in conflict herewith be and the same are hereby repealed.
Section 9: Should any section or provision of this
ordinance or portion hereof, any paragraph, sentence, or
word be declared by a court of competent jurisdiction to be
10
".mord, CT 06104.2944
CAll TOll FREE: 1.800.243.5250
REPLY MESSAGE
Fold At (.) To Fit Grayarc Window Envelope It EW10P
REORDER ITEM" F269
r ~€S GO'-OEN
TO $'rfNIOR Crrf AA"''''6'<.
-,
FROM
~~ 5~A::.../ r
/fc:r~N<;;:- .2J/"'U!!!f!f:::..~~ o,c ~uc;. ~
SUBJECT: ........J);h:~#~/~....~..~~€ .........DATE:.....i!.-r:A...............
frOLD . () ~
J>lJ,."P;;te~ ytlO Ml>...$"'T" ~E> A.. M..NIV......, /D O~6\./""~ AA/D ..PMaP~
8~ 70 ?He- I'f~ ~ r~ ~op~o-y
PLEASE REPLY TO
.
SIGNED
REPLY
DATE:
SIGNED
Item _ F269 Grayare. P,O, Box 2944. Hartford. CT 06104.2944
@ Wh<leler Group. Ine, 1982
THIS COpy FOR PERSON ADDRESSED
MEMORANDUM
TO:
Carmen Annunziato
Planning Director
FROM:
Kevin J. Hallahan
Forester/Horticulturist
DATE:
september 2, 1988
RE:
Safe Keeping Self-Storage - Site Plan
The following comments pertain to the landscape plan for the
above project:
1. The applicant must use fifty percent native species of
trees, and thirty percent native species for hedge
materials.
2. The hedge along Congress Avenue and the parking lot must be
36" height.
3. The Bottlebrush tree shown as 6'-8' must be minimum height
of 8'.
4. The type of sod used should be noted.
5. The applicant must provide a landscape plan for the Congress
Avenue median which affronts his property. (Comprehensive
Plan requirement). This would involve irrigation, and a
permit from the Palm Beach County Engineering Department.
$-=<:~l v'1-~
Kevin J. allahan
Forester/Horticulturist
KJH:ad
DOC: STORAGE
'~:JCEIVl?D
)E:P ~ ..
PLANNJNG OEPT:
......1..