FIF20.73 - North Congress Ave - Elevations_v1-Feedback600
TYP.
201
TYP.
201
TYP.
202
TYP.
202 TYP.
202
204204
204204
TYP.
205
TYP.
208
TYP.
206
TYP.
208
TYP.
206
TYP.
208
TYP.
205
204 204204
ALL BOLLARDS TO RECEIVE BOLLARD
SLEEVE FROM IDEAL SHIELD. E-PT-1
FINISH TO BE APPLIED
?
E-PT-2
E-PT-2
E-PT-1
E-PT-2
E-PT-1
E-PT-2
FIFTH THIRD SIGN BY VENDOR, TO BE
SURFACE MOUNTED.
E-PT-1
E-PT-1 IS APPLIED TO TRIM
E-PT-2 IS FOR THE MAIN BUILDING
209
E-PT-5
E-PT-2
E-PT-5
E-PT-5
E-PT-2
E-PT-5
E-PT-1
E-PT-1
E-PT-1
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
E-PT-5
E-PT-1
TYP.
TYP.
201
TYP.
201
TYP.
206
TYP.
203
TYP.
203
TYP.
203
TYP.
203
TYP.
204
TYP.
204
TYP.
204
TYP.
204
TYP.
205
TYP.
206
TYP.
208
TYP.
207 TYP.
208
TYP.
208
ALL BOLLARDS TO RECEIVE BOLLARD
SLEEVE FROM IDEAL SHIELD. E-PT-1
FINISH TO BE APPLIED.
E-PT-2E-PT-2E-PT-5
E-PT-1 IS APPLIED TO TRIM
E-PT-2 IS FOR THE MAIN BUILDING
E-PT-1
E-PT-5
E-PT-2
E-PT-5
E-PT-5
E-PT-5
E-PT-2
E-PT-5
E-PT-5
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
E-PT-1 TYP.
TYP.This document is the product and property of Baxter Hodell Donnelly Preston, Inc. Neither the document nor the information it contains may be copied or used for other than the specific project for which it was prepared without the written consent of Baxter Hodell Donnelly Preston, Inc.Revit Template Version 202112345678910111213141516171819
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R 12345678910111213141516171819
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
Drawn
Project Manager
Checked
Initial Drawing Date
Project NumberCINCINNATICOLUMBUSRALEIGHCHARLOTTEwww.bhdp.comBHDP ARCHITECTURE302 WEST THIRD STREETSUITE 500CINCINNATI, OHIO 45202PHONE 513.271.1634BIM 360://FIF2073 North Congress Ave (Mattress One)/FIF20.73 - North Congress Ave - Arch - R20.rvt 5/12/2023 9:13:03 AM
M. SMITH
A. PONTING
N. McCleese
1.12.23
FIF20.73
A201EXTERIOR ELEVATIONSFIFTH THIRD BANK - BOYNTON BEACHHEAPY ENGINEERING | 1400 W. DOROTHY LANETHE KLEINGERS GROUP | 6219 CENTRE PARK DRIVEINTERIOR RENOVATION600 N CONGRESS AVE, BOYNTON BEACH, FL 334261/4" = 1'-0"A201
A19 EXTERIOR ELEVATION - SOUTH
1/4" = 1'-0"A201
J19 EXTERIOR ELEVATION - NORTH No.Issue/Revision/SubmissionDate1ISSUE FOR BID AND PERMIT01/12/20232ADDENDUM 105/03/2023SHEET KEYNOTES
201 RECAULK AND SEAL DOWNSPOUT DRAIN HOLE AT GUTTER.
202 DO NOT ENTER SIGNAGE, COORDINATE WITH BANK SIGN
VENDOR
203 SURFACE MOUNTED SIGNAL FIXTURE CENTERED OVER
DRIVE-THRU LANE. REFER TO ELECTRICAL AND SIGN
PACKAGE.
204 EXISTING EXTERIOR CONSTRUCTION TO REMAIN. PRESSURE
WASH/CLEAN, PATCH & REPAIR CRACKS, AND RECAULK AS
NEEDED. PAINT AS INDICATED.
205 G.C. TO INSPECT ROOF AND REPAIR BROKEN TILES- MATCH
EXISTING. APPROX. 30-50 BROKEN TILES. MATCH EXISTING
EXISTING MATERIAL STYLE AND COLOR.
206 INSPECT GUTTERS AND FASCIA- PATCH AND REPAIR AS
NEEDED. ALL DRAINS FROM GUTTERS INTO INTERIOR
DOWNSPOUTS TO BE INSPECTED, CLEANED, AND
RECAULKED/SEALED.
207 ROOF VALLEY AT DRIVE-THRU TO BE INSPECTED AND
REPAIRED. RE-FINISH/SEAL AND REPLACE BROKEN TILES AS
REQUIRED.
208 EXISTING ROOF VENTS (O'HAGEN) TO BE INSPECTED AND
REPLACED AS NEEDED. APPROX. TWO DAMAGED VENTS
NEED REPLACED.
209 BUILDING SHALL HAVE ADDRESS NUMBERS FACING THE
STREET A MINIMUM OF 6" HIGH IN COMPLIANCE WITH NFPA 1 -
10.11.1.1. CONFIRM EXISTING ADDRESS SIGN SATISFIES
THESE REQUIREMENTS AND REMOVE/ REPLACE AS
REQUIRED. COORDINATE FINAL SIZE/ LOCATION WITH FIRE
DEPARTMENT.
EXTERIOR FINISH MANUFACTURER COLOR COMMENTS
E-PT-1 BENJAMIN MOORE HC-175
BRIAR-WOOD
USED ON TRIM
E-PT-2 BENJAMIN MOORE AC-40 GLACIER
WHITE
FOR MAIN BUILDING
E-PT-5 BENJAMIN MOORE 1535 SEATTLE
MIST
TRIM ACCENTS
2
2
E-PT-1
E-PT-2
E-PT-5
BHDP Authorization Number: AA0002664
05/15/2023
APPROVED APPROVED APPROVED APPROVED APPROVED APPROVED APPROVED APPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVED
APPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVED
Planning & Zoning Division
June 15, 2023
Project #: ___________________________MMRP-2023.06.4432
TYP.
201
TYP.
201
TYP.
205
TYP.
208
TYP.
207
TYP.
204
TYP.
204
TYP.
208
TYP.
205
TYP.
204
TYP.
204
TYP.
204
204
ALL BOLLARDS TO RECEIVE BOLLARD
SLEEVE FROM IDEAL SHIELD. COLOR
TO BE DETERMINED, NO SUBSTITUTION
E-PT-1 E-PT-2
E-PT-2
E-PT-1 IS APPLIED TO TRIM
E-PT-2 IS FOR THE MAIN BUILDING
E-PT-1
E-PT-1
E-PT-2
E-PT-5
E-PT-2
E-PT-5
E-PT-5
E-PT-2
E-PT-5
E-PT-1
E-PT-1
E-PT-1
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
E-PT-1
TYP.
TYP.
600
TYP.
204
TYP.
204
206
208 205
206
208
FIFTH THIRD SIGN BY VENDOR, TO BE
SURFACE MOUNTED.
E-PT-2
E-PT-1
E-PT-2
E-PT-1
E-PT-1
E-PT-2
E-PT-1 IS APPLIED TO TRIM
E-PT-2 IS FOR THE MAIN BUILDING
E-PT-1
E-PT-2
E-PT-2
209
2
E-PT-5
E-PT-2
E-PT-5
E-PT-2
E-PT-5
E-PT-1
E-PT-1
E-PT-1
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.This document is the product and property of Baxter Hodell Donnelly Preston, Inc. Neither the document nor the information it contains may be copied or used for other than the specific project for which it was prepared without the written consent of Baxter Hodell Donnelly Preston, Inc.Revit Template Version 202112345678910111213141516171819
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R 12345678910111213141516171819
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
Drawn
Project Manager
Checked
Initial Drawing Date
Project NumberCINCINNATICOLUMBUSRALEIGHCHARLOTTEwww.bhdp.comBHDP ARCHITECTURE302 WEST THIRD STREETSUITE 500CINCINNATI, OHIO 45202PHONE 513.271.1634BIM 360://FIF2073 North Congress Ave (Mattress One)/FIF20.73 - North Congress Ave - Arch - R20.rvt 5/12/2023 9:13:19 AM
M. SMITH
A. PONTING
N. McCleese
1.12.23
FIF20.73
A202EXTERIOR ELEVATIONSFIFTH THIRD BANK - BOYNTON BEACHHEAPY ENGINEERING | 1400 W. DOROTHY LANETHE KLEINGERS GROUP | 6219 CENTRE PARK DRIVEINTERIOR RENOVATION600 N CONGRESS AVE, BOYNTON BEACH, FL 33426No.Issue/Revision/SubmissionDate1ISSUE FOR BID AND PERMIT01/12/20232ADDENDUM 105/03/20231/4" = 1'-0"A202
J19 EXTERIOR ELEVATION - WEST
1/4" = 1'-0"A202
A19 EXTERIOR ELEVATION- EAST
SHEET KEYNOTES
201 RECAULK AND SEAL DOWNSPOUT DRAIN HOLE AT GUTTER.
204 EXISTING EXTERIOR CONSTRUCTION TO REMAIN.
PRESSURE WASH/CLEAN, PATCH & REPAIR CRACKS, AND
RECAULK AS NEEDED. PAINT AS INDICATED.
205 G.C. TO INSPECT ROOF AND REPAIR BROKEN TILES- MATCH
EXISTING. APPROX. 30-50 BROKEN TILES. MATCH EXISTING
EXISTING MATERIAL STYLE AND COLOR.
206 INSPECT GUTTERS AND FASCIA- PATCH AND REPAIR AS
NEEDED. ALL DRAINS FROM GUTTERS INTO INTERIOR
DOWNSPOUTS TO BE INSPECTED, CLEANED, AND
RECAULKED/SEALED.
207 ROOF VALLEY AT DRIVE-THRU TO BE INSPECTED AND
REPAIRED. RE-FINISH/SEAL AND REPLACE BROKEN TILES
AS REQUIRED.
208 EXISTING ROOF VENTS (O'HAGEN) TO BE INSPECTED AND
REPLACED AS NEEDED. APPROX. TWO DAMAGED VENTS
NEED REPLACED.
209 BUILDING SHALL HAVE ADDRESS NUMBERS FACING THE
STREET A MINIMUM OF 6" HIGH IN COMPLIANCE WITH NFPA
1 - 10.11.1.1. CONFIRM EXISTING ADDRESS SIGN SATISFIES
THESE REQUIREMENTS AND REMOVE/ REPLACE AS
REQUIRED. COORDINATE FINAL SIZE/ LOCATION WITH FIRE
DEPARTMENT.
EXTERIOR FINISH MANUFACTURER COLOR COMMENTS
E-PT-1 BENJAMIN MOORE HC-175
BRIAR-WOOD
USED ON TRIM
E-PT-2 BENJAMIN MOORE AC-40 GLACIER
WHITE
FOR MAIN BUILDING
E-PT-5 BENJAMIN MOORE 1535 SEATTLE
MIST
TRIM ACCENTS
2
2
E-PT-1
E-PT-2
E-PT-5
BHDP Authorization Number: AA0002664
05/15/2023
APPROVED APPROVED APPROVED APPROVED APPROVED APPROVED APPROVED APPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVED
APPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVED
Planning & Zoning Division
June 15, 2023
Project #: ___________________________MMRP-2023.06.4432