Loading...
Architectural Plans-FeedbackREVISIONS DRAWING NUMBER JOB NUMBER DATE DRAWING TITLE DRAWN BY CONSTRUCTION SEAL ISSUED FOR : BIDS PERMIT PROJECT TITLE THIS DOCUMENT IS THE PROPERTY OF CURRIE SOWARDS AGUILA ARCHITECTS INC. ALL RIGHTS ARE RESERVED. ANY POSSESSION, REPRODUCTION OR OTHER USE OF THIS DOCUMENT, WITHOUT THE WRITTEN CONSENT OF CURRIE SOWARDS AGUILA ARCHITECTS INC., IS PROHIBITED.Architecture, Planning, Interiors, & Sustainable Design AA26001584 185 NE 4TH AVENUE SUITE 101 DELRAY BEACH, FL 33483 THESE DRAWINGS ARE PREPARED PER ESTABLISHED INDUSTRY STANDARDS AND REPRESENT THE ARCHITECT AND ENGINEERS DESIGN CONCEPT. THEY ARE NOT INTENDED TO PROVIDE EVERY DETAIL OR CONDITION REQUIRED TO CONSTRUCT THE BUILDING. THE CONTRACTOR THROUGH SUBMITTALS AND OTHER COORDINATION EFFORTS IS FULLY RESPONSIBLE FOR PROVIDING A COMPLETE AND OPERATIONAL BUILDING WHETHER INDICATED ON THE PLANS OR NOT. T:(561) 276-4951 F:(561) 243-8184 E-MAIL: office@csa-architects.com SPA TENNIS FACILITIES RENOVATION HUNTERS RUN 3500 CLUBHOUSE LN. BOYNTON BEACH, FL 33436 07/03/23 FLEX SUB 07/24/2023DRC NUM.DESCRIPTION 220501 DATE PERMIT SETJT. 07/03/2023 ARCHITECTURAL ABBREVIATIONS LOCATION MAP DETAIL NUMBER DETAILED AREA SHEET NUMBER SECTION NUMBER DETAIL NUMBER SHEET NUMBER SHEET NUMBER SHEET NUMBER ELEVATION ELEVATION ROOM NUMBER SHEET NUMBER HEIGHT ABOVE FINISHED FLOOR ARCHITECTURAL SYMBOLS ALIGN W/ ESTABLISHED SURFACE DOOR NUMBER WINDOW TYPE WALL TYPE A0.00 GENERAL NOTES AND SYMBOLS GENERAL NOTES 1.THIS PROJECT IS TO BE CONSTRUCTED UNDER THE PROVISIONS OF THE FLORIDA BUILDING CODE SEVENTH EDITION, FLORIDA ACCESSIBILITY CODE 2020, NFPA 1 AND NFPA 101, ADA, FLORIDA STATE STATUTES AND ALL OTHER APPLICABLE CODES. 2.THE CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE HIMSELF WITH THE EXISTING CONDITIONS AND NOTIFY THE ARCHITECT OF ANY OBSERVED DISCREPANCIES PRIOR TO SUBMISSION OF BIDS. 3.DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALE DIMENSIONS. 4.ANY WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED. 5.THESE DRAWINGS ARE DIAGRAMMATIC AND ARE INTENDED TO SHOW THE DESIGN INTENT ONLY. THEY DO NOT SHOW EVERY MINOR DETAIL OF CONSTRUCTION. ALL TRADES ARE RESPONSIBLE FOR FURNISHING COMPLETE BUILDING SYSTEMS AND ALL ITEMS THAT WOULD NORMALLY BE CONSIDERED INCIDENTAL TO THEIR INSTALLATION. 6.THE CONTRACTOR SHALL REVIEW THE PROJECT CONTRACT DOCUMENTS AND NOTIFY THE ARCHITECT OF ANY OBSERVED DISCREPANCIES PRIOR TO START OF CONSTRUCTION. 7.ALL EXPOSED STUCCO, CEMENT, PLASTER OR GYPSUM BOARD SURFACES TO BE PAINTED UNLESS OTHERWISE NOTED. COLOR TO BE SELECTED BY ARCHITECT. REFER TO SPECIFICATION FOR APPLICATION PROCEDURE. 8.ALL FIRE RATED WALLS AND PARTITIONS AND PARTITIONS INSULATED FOR SOUND TRANSMISSION ARE TO RUN CONTINUOUS FROM FLOOR TO UNDERSIDE OF ROOF/FLOOR DECK ABOVE. ALL JOINTS TO BE TAPED AND SPACKLED AND ANY DUCT PENETRATIONS TO BE FIRE DAMPERED AS REQUIRED BY CODE. 9.ALL CEMENT PLASTER OR PORTLAND CEMENT BOARD ABUTTING OTHER MATERIAL TO BE FINISHED WITH METAL EDGE STRIPS. 10.ALL ELECTRICAL CABINETS, FIRE EXTINGUISHERS, CABINETS AND OTHER RECESSED EQUIPMENT IN FIRE RATED WALLS SHALL BE BACKED WITH 5/8" TYPE X GYPSUM BOARD OR AS REQUIRED TO MAINTAIN THE RATING. 11.PROVIDE DOUBLE STUDS OR WOOD BLOCKING AS REQUIRED TO SUPPORT WALL MOUNTED EQUIPMENT. BLOCKING IN CONTACT WITH MASONRY/CONCRETE OR MOIST/HUMID CONDITIONS SHALL BE PRESSURE TREATED. 12.ALL EXPOSED METAL TO BE PAINTED. COLOR AS SELECTED BY THE ARCHITECT. REFER TO SPECIFICATION FOR APPLICATION PROCEDURE. 13.NO ASBESTOS IN ANY FORM WILL BE PERMITTED IN THIS BUILDING. 14.ALL DIMENSIONS SHOWN ON THIS PLAN ARE NOMINAL. THE CONTRACTOR SHALL BE RESPONSIBLE TO ADJUST ACTUAL CONSTRUCTION DIMENSIONS SLIGHTLY TO ALLOW FOR EXACT MATERIAL THICKNESS AND REQUIRED CLEARANCE. DIMENSIONS ON PLANS ARE TO FINISH OF INTERIOR STUD PARTITIONS, CENTERLINE OF CONSTRUCTION LINES, AND FACE OF MASONRY. 15.THE STRUCTURAL DRAWINGS SHALL TAKE PRECEDENCE OVER ARCHITECTURAL DRAWINGS WITH RESPECT TO COLUMN AND STRUCTURAL ELEMENTS LOCATIONS. CONTRACTOR SHALL NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPENCIES. 16.IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND EACH OF HIS SUBCONTRACTORS TO REVIEW ALL DRAWINGS, PROJECT MANUAL ADDENDA ETC. TO ASSURE COORDINATION OF ALL WORK AFFECTING EACH TRADE. FAILURE TO REVIEW ALL CONTRACT DOCUMENTS FOR APPLICABLE ITEMS OF WORK SHALL NOT RELIEVE THE RESPONSIBLE PARTY FROM PERFORMING WORK SO REQUIRED. WORK SHOWN ON ONE DRAWING IS AS GOOD AS IF SHOWN ON EVERY DRAWING. 17.EXISTING CONDITIONS- THE EXISTING SITE DIMENSIONS AND CONDITIONS SHOWN ON THESE DRAWINGS ARE ASSUMED TO BE ACCURATE BASED ON AVAILABLE INFORMATION. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS ON THE JOB SITE AND NOTIFY THE ARCHITECT OF DEVIATIONS FROM THESE DRAWINGS. 18.N.I.C. ITEMS- ALL ITEMS MARKED N.I.C. (NOT IN CONTRACT) ARE TO BE FURNISHED BY THE OWNER. CONSULT THE ARCHITECT FOR ANY ADDITIONAL REQUIRED INFORMATION NOT SHOWN. 19.DUCTS, PIPES, CONDUIT, ETC.- ALL VERTICAL AND HORIZONTAL DUCTS, PIPES, CONDUIT, ETC. (WHETHER SHOWN OR NOT) IN FINISHED ROOMS SHALL BE LOCATED IN WALL. ITEMS THAT CANNOT BE LOCATED IN WALL SHALL BE FURRED IN AND FINISHED TO MATCH ADJACENT FINISHED SURFACES AND ANY REQUIRED WALL OR CEILING RATINGS. VERIFY ACCEPTABILITY WITH ARCHITECT PRIOR TO ENCASEMENT. 20.ACCESS PANELS: FURNISH AND INSTALL ACCESS PANELS, WHETHER SHOWN OR NOT, IN WALLS AND NON-ACCESSIBLE TYPE CEILINGS WHERE SERVICE OR ADJUSTMENT TO MECHANICAL, FIRE PROTECTION, PLUMBING, OR ELECTRICAL EQUIPMENT IS REQUIRED. 21.FIXTURES, LAVATORIES AND SINKS SHALL BE INSTALLED A MINIMUM OF 4" FROM FINISHED SIDE WALLS. WATER CLOSETS SHALL BE INSTALLED A MINIMUM OF 15" FROM FINISHED SIDE WALLS OR TOILET PARTITIONS TO CENTERLINE OF FIXTURE (18" TO CENTERLINE FOR HANDICAP FIXTURES). 22.PRECAUTIONS: DO NOT PROCEED WITH WORK IF UNFORESEEN CONDITIONS ARE DISCOVERED WHICH COULD CAUSE ADVERSE EFFECTS UPON THE STRUCTURE OR ITS OCCUPANTS. REPORT ANY SUCH CONDITION IMMEDIATELY TO THE ARCHITECT. TAKE PRECAUTIONS TO PROPERLY SUPPORT THE STRUCTURE. THE CONTRACTOR SHALL REPORT ALL TOXIC MATERIALS LOCATED TO OWNER, ARCHITECT AND AUTHORITIES HAVING JURISDICTION. REMOVAL OF MATERIAL WILL BE COMPLETED PER APPROVED MEANS BEFORE CONSTRUCTION CONTINUES. 23.SAFETY: PROVIDE, ERECT AND MAINTAIN BARRICADES, LIGHTING AND GUARDRAILS AS REQUIRED BY APPLICABLE REGULATORY AGENCIES TO PROTECT OCCUPANTS OF BUILDING AND WORKERS. 24.IF DISCREPANCIES EXIST BETWEEN SPECIFICATIONS AND DRAWINGS, THE MORE STRINGENT REQUIREMENT SHALL PREVAIL. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES TO OBTAIN CLARIFICATION. 25.EXIT ACCESS: MAINTAIN FREE, SAFE, AND APPROVED MEANS OF EGRESS IN AND OUT OF PROJECT LOCATION IN ACCORDANCE WITH REQUIREMENTS OF APPLICABLE REGULATORY AGENCIES. 26.FINISHES: ALL FINISHES AND COLORS OF FIXTURES, EQUIPMENT, LIGHTS, DIFFUSERS, SINKS, PAINT, WALLCOVERINGS, ETC. SHALL BE SELECTED BY ARCHITECT. SUBMIT FULL RANGE OF AVAILABLE FINISHES TO ARCHITECT FOR SELECTION. REFER TO FINISH SCHEDULE AND NOTES. 27.STRUCTURAL REINFORCEMENT: IN THE EVENT THAT WINDOW OR STOREFRONT SIZES DICTATE THE NEED FOR ADDITIONAL STRUCTURAL REINFORCEMENT, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE SUCH REINFORCEMENT DESIGNED BY A REGISTERED ENGINEER AS PART OF THE WINDOW SYSTEM FOR NO ADDITIONAL COST. 28.PARTITIONS THAT ABUT THE STOREFRONT OR WINDOWS SHALL HAVE PAINTED ALUMINUM END CLOSURE. 29.THE GENERAL CONTRACTOR SHALL COORDINATE OPENINGS IN SLABS AND WALLS AS REQUIRED FOR THE INSTALLATION OF MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION ITEMS. DO NOT CUT CONCRETE COLUMNS, BEAMS, OR OTHER STRUCTURAL ELEMENT WITHOUT THE PRIOR WRITTEN PERMISSION OF THE STRUCTURAL ENGINEER OF RECORD. 30.SUPPLY AND RETURN REGISTERS IN CEILINGS SHALL BE INSTALLED OFFSET FROM ONE ANOTHER TO AVOID SOUND PASSAGE FROM ONE ROOM TO ANOTHER. SOUND RATED ROOMS SHALL HAVE SOUND BOOTS INSTALLED IN THE DUCTWORK TO RESTRICT THE PASSAGE OF SOUND. 31.CONTRACTOR SHALL HOLD A MEETING OF ALL SUB-CONTRACTORS WHO HAVE WORK THAT IS TO BE INSTALLED ABOVE THE CEILING PRIOR TO THE START OF THEIR INSTALLATION FOR THE PURPOSE OF COORDINATING NECESSARY CLEARANCES AND PROPER ROUTING. CONTRACTOR TO SUBMIT A TYPICAL SECTION DRAWN TO SCALE SHOWING THE ASSIGNED LAYERING. 32.CONTRACTOR SHALL CARRY BANDING, SCORE LINES, FINISHES ETC. AROUND EXTERIOR ARCHITECTURAL ELEMENTS SUCH AS COLUMNS, ARCHES, SCREEN WALLS ETC. WHEN NO ELEVATION IS SHOWN FOR THOSE SIDE OR REAR ELEVATIONS. 33.WHERE A STUD WALL ABUTS A FURRED OUT MASONRY WALL THE CONTRACTOR SHALL HOLD THE FACE OF THE FURRING STRIP, SO THAT A SMOOTH UNINTERRUPTED LAYER OF GYPSUM BOARD MAY BE APPLIED. 34.THE CONTRACTOR SHALL SELECT APPROPRIATE MATERIALS THAT ARE BEST SUITED FOR THEIR INTENDED USE. 35.THE GENERAL CONTRACTOR SHALL REVIEW WITH THE OWNER, ALL LIGHTING FIXTURES, PLUMBING FIXTURES AND DOOR HARDWARE PRIOR TO ORDER PLACEMENT. IN THE EVENT THE OWNER IS NOT GIVEN THE OPPORTUNITY TO REVIEW AND APPROVE SAID FIXTURES, THE ARCHITECT SHALL NOT BE HELD RESPONSIBLE FOR REPLACEMENT, RETURN OR RESTOCKING FEES ASSOCIATED WITH CORRECTING THE ITEMS TO THE OWNER'S SATISFACTION. 36.ANY EXPOSED PLUMBING, ELECTRICAL OR FIRE SPRINKLER CONDUIT OR PIPING SHALL BE PAINTED TO MATCH ADJACENT SURFACES UNLESS OTHERWISE NOTED. 37.WHEN STUCCO IS APPLIED TO A VERTICAL SURFACE, THE CONTRACTOR SHALL INSTALL STUCCO CONTROL JOINTS AS INDICATED IN THE CONTRACT DOCUMENTS AND AS OTHERWISE NECESSARY ON A REGULAR GRID NOT EXCEEDING 140 SF, AS APPROVED BY THE ARCHITECT. 38.WHEN STUCCO IS APPLIED TO A HORIZONTAL SURFACE, THE CONTRACTOR SHALL INSTALL STUCCO CONTROL JOINTS AS INDICATED IN THE CONTRACT DOCUMENTS AND AS OTHERWISE NECESSARY ON A REGULAR GRID NOT EXCEEDING 100 SF, AS APPROVED BY THE ARCHITECT. 39.THE ARCHITECTURAL DRAWINGS ARE PART OF THE CONTRACT DOCUMENTS AND DO NOT, BY THEMSELVES, PROVIDE ALL THE INFORMATION REQUIRED TO PROPERLY CONSTRUCT THE PROJECT. THE GENERAL CONTRACTOR SHALL CONSULT THE STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING, FIRE PROTECTION, CIVIL, LANDSCAPING, AND SPECIALTY CONSULTANT'S DRAWINGS AND COORDINATE THE INFORMATION CONTAINED IN THOSE DRAWINGS WITH THE ARCHITECTURAL DRAWINGS TO PROPERLY CONSTRUCT THE PROJECT. REFER TO MECHANICAL, ELECTRICAL, PLUMBING AND STRUCTURAL FOR ADDITIONAL OPENINGS, DEPRESSIONS, PENETRATIONS, INSERTS, DRAINS, ETC. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT, BEFORE PROCEEDING WITH ANY WORK. THIS COORDINATION IS THE CONTRACTORS RESPONSIBILITY, AND NO EXTRA COMPENSATION WILL BE ALLOWED RESULTING FROM THE CONTRACTORS FAILURE TO COMPLY WITH THESE REQUIREMENTS. SITE PLAN PROPOSAL AFTER DEMOLITION OF THE CURRENT TENNIS FACILITY AND ADJACENT PLATFORM. PROJECT SCOPE OF WORK CURRIE SOWARDS AGUILA ARCHITECTS ARCHITECT : 185 NE 4th Avenue Suite 101 Delray Beach, FL 33483 TEL: 561-276-4951 FAX: 561-243-8184 OWNER : HUNTERS RUN PROPERTY OWNERS ASSOC INC COMMUNITY MGMT OFFICE (CMO) C/O 3500 CLUBHOUSE LN3825 BOYNTON BEACH FL 33436 6002 HUNTERS RUN TENNIS FACILITIES RENOVATION 3500 CLUBHOUSE LN, BOYNTON BEACH, FL 33436 HUNTERS RUN COUNTRY CLUB **THIS PROJECT WAS CONSTRUCTED UNDER THE 2004 FLORIDA BUILDING CODE, FLORIDA FIRE PREVENTION CODE (FFPC) 2004 EDITION WITH BROWARD COUNTY AMENDMENTS WHICH INCLUDES NFPA 101, 2003 EDITION, NFPA 1, 2003, & STATE STATUTES, 2003 EDITION. PROJECT INFORMATION PROJECT ADDRESS: SCOPE OF WORK: EXISTING BUILDING AREA: ZONING: TYPE OF USE: TYPE OF OCCUPANCY: TYPE OF CONSTRUCTION: ALTERATION TYPE: APPLICABLE CODES ARCHITECTURE: ELECTRICAL/FIRE: PLUMBING/MECHANICAL: 3500 CLUBHOUSE LN, BOYNTON BEACH, FL 33436 SITE PLAN PROPOSAL AFTER DEMOLITION OF THE CURRENT TENNIS FACILITY AND ADJACENT PLATFORM. (6,480 S.F.) INFILL PLANNED UNIT DEVELOPMENT ASSEMBLY RESIDENTIAL / CLUBHOUSE (A-2) TYPE II-B (MASONRY NON COMBUSTIBLE) N/A - DEMOLITION FLORIDA BUILDING CODE EXISTING 2020, FLORIDA BUILDING CODE 2020 AND 2020 FLORIDA ACCESSIBILTY CODE NFPA 70, NATIONAL ELECTRICAL CODE, FLORIDA FIRE PREVENTION CODE 2020 ADDITION,NFPA 101 LIFE SAFETY CODE FLORIDA BUILDING CODE PLUMBING 2020 EDITION FLORIDA BUILDING CODE MECHANICAL 2020 EDITION SCOPE OF WORK LOCATION SITE SPACE LOCATION SHEET INDEX SHEET #SHEET TITLE LAST REVISED ARCHITECTURAL COVERSHEET TENNIS BUILDING FLOOR PLAN & ELEVATIONS 08/15/23 A0.02 A0.00 REVISION # 2 BEVERAGE STATION FLOOR PLAN & ELEV. A0.04 ARCHITECTURAL SITE PLAN A0.01 SITE PLAN PHOTOMETRICSPM.01 08/15/232 09/20/233 08/15/232 TENNIS BUILDING COLOR ELEV. (New Sheet) A0.05 3 09/20/23 3 APPROVED APPROVED APPROVED APPROVED APPROVED APPROVED APPROVED APPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVED APPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVED Planning & Zoning Division September 25, 2023 Project #: ___________________________MMSP-2023.07.15798 10' CLF 10' CLF SAND TRAP 10' CLF 10' CLF EXISTING OAK TREES TO REMAIN (TYP) EXISTING TENNIS COURT EXISTING TENNIS COURT CONCRETE SIDEWALK EXISTING CART PARKING 119'FPLUE EAST TRACT 21 LINESAND TRAP SAND TRAP 120' FPL UE SOUTHEASTERLY TRACT 21 LINEMAINTENANCE SHED 8'X20' EXISTING PARKING AREA BEVERAGE STATION 10' x 15' EXISTING TENNIS COURT EXISTING TENNIS COURT BOCCE COURT EXISTING TENNIS COURT EXISTING TENNIS COURT EXISTING TENNIS COURT EXISTING PARKING AREA TO BE USED FOR TENNIS FACILITIES 72' EXISTING TENNIS COURT EXISTING TENNIS COURT L.A. L.A. L.A. L.A. EXISTING WATER STATION SEE ADA RAMP DRAWINGS BY MANUFACTURER RECREATION TRACT 21 SUMMIT PLAT 1 SOUTH TRACT 21 LINE 120' FPL UE 10 10 1212 9 18 EX. FIRE HYDRANT L.A. L.A. SHADE STRUCTURE 16' x 62' SHADE STRUCTURE 30' x 50' EXISTING CART PATH TRACT 12 SUMMIT PLAT 1 PCN: 08-42-46-01-04-000-0010 TRACT 12 SUMMIT PLAT 1 PCN: 08-42-46-01-04-000-0010 EXISTING CART PATH BOCCE COURT TURF L.A. TURF TURF L.A. TENNIS BUILDING "A" 24'X56' SOFT SEATING / BBQ AREA A0.02 A A0.04 B REVISIONS DRAWING NUMBER JOB NUMBER DATE DRAWING TITLE DRAWN BY CONSTRUCTION SEAL ISSUED FOR : BIDS PERMIT PROJECT TITLE THIS DOCUMENT IS THE PROPERTY OF CURRIE SOWARDS AGUILA ARCHITECTS INC. ALL RIGHTS ARE RESERVED. ANY POSSESSION, REPRODUCTION OR OTHER USE OF THIS DOCUMENT, WITHOUT THE WRITTEN CONSENT OF CURRIE SOWARDS AGUILA ARCHITECTS INC., IS PROHIBITED.Architecture, Planning, Interiors, & Sustainable Design AA26001584 185 NE 4TH AVENUE SUITE 101 DELRAY BEACH, FL 33483 THESE DRAWINGS ARE PREPARED PER ESTABLISHED INDUSTRY STANDARDS AND REPRESENT THE ARCHITECT AND ENGINEERS DESIGN CONCEPT. THEY ARE NOT INTENDED TO PROVIDE EVERY DETAIL OR CONDITION REQUIRED TO CONSTRUCT THE BUILDING. THE CONTRACTOR THROUGH SUBMITTALS AND OTHER COORDINATION EFFORTS IS FULLY RESPONSIBLE FOR PROVIDING A COMPLETE AND OPERATIONAL BUILDING WHETHER INDICATED ON THE PLANS OR NOT. T:(561) 276-4951 F:(561) 243-8184 E-MAIL: office@csa-architects.com SPA TENNIS FACILITIES RENOVATION HUNTERS RUN 3500 CLUBHOUSE LN. BOYNTON BEACH, FL 33436 07/03/23 FLEX SUB 07/24/2023DRC NUM.DESCRIPTION 220501 DATE PERMIT SETJT. 07/03/2023 A0.01 ARCHITECTURAL SITE PLAN SCALE: SITE PLAN1 A1.01 1" = 30' N CITY COMMENTS 2 08.15.23 2 APPROVED APPROVED APPROVED APPROVED APPROVED APPROVED APPROVED APPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVED APPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVED Planning & Zoning Division September 25, 2023 Project #: ___________________________MMSP-2023.07.15798 24"x54" 56'-0"23'-4"24"x54" 24"x54" 24"x54" 24"x54" 24"x54" 24"x54" 24"x54" 24"x54" Ø5'-0"Ø5' -0 "Ø5'-0"36"x80" 36"x80" 36"x80" 36"x80"36"x80"36"x80"ADA RESTROOMS REFER TO MANUFACTURER PRODUCT APPROVAL DRAWINGS. 12'-0" RAMP 1:12 6'-0" LANDING 12'-0" RAMP 1:12 LANDING 8'-0"4'-0"4'-0"72"x80" UP.SLOPED PAVED AREA UP. A0.02 2 A0.02 1 STRUCTURE TO BE PERMANENTLY ATTACHED AND SECURE TO GROUND REFER TO MANUFACTURER AND PRODUCT APPROVAL DRAWINGS DETAILS. A0.02 3 A0.02 5 A0.02 4 8'-0"AC UNIT AC UNIT ADA COUNTER ACCESSIBLE REFER TO MANUFACTURER PRODUCT APPROVAL DRAWINGS. ADA ACCESSIBLE RAMP REFER TO MANUFACTURER PRODUCT APPROVAL DRAWINGS. FIRE EXTINGUISHER. ABC MULTIPURPOSE DRY CHEMICAL 5 LBS. UL APPROVED 2:A 10:B C HOSE DISCHARGE. OCCUPANCY DATA - OCCUPANCY: B (BUSINESS) - OCCUPANT LOAD : 9 (AS PER 7.3.1.2) SPLIT FACE CMU LOW WALL . SPLIT FACE CMU LOW WALL .2'-6"VERIFY2'-0"1'-0" SLOPED PAVED AREA ADA ACCESSIBLE RAMP REFER TO MANUFACTURER PRODUCT APPROVAL DRAWINGS.3'-0"24"x54" 24"x54" 24"x54" 24"x54" 24"x54" 24"x54" 24"x54" 72"x80"10'-4"7"VARIES10'-11"10'-4"7"VARIES10'-11"GRADE GRADE DOOR AND TRIM PAINTED COLOR DIAMOND WHITE. 0C-61 BENJAMIN MOORE SPLIT FACE CMU LOW WALL . ALL TRIMS PAINTED COLOR DIAMOND WHITE. 0C-61 BENJAMIN MOORE SINGLE PLY ROOFING COLOR WHITE SYNTHETIC STUCCO WALLS PAINTED COLOR VAPOR. AF-35 BENJAMIN MOORE ALL TRIMS PAINTED COLOR DIAMOND WHITE. 0C-61 BENJAMIN MOORE SYNTHETIC STUCCO WALLS PAINTED COLOR VAPOR. AF-35 BENJAMIN MOORE SINGLE PLY ROOFING COLOR WHITE ALL TRIMS PAINTED COLOR DIAMOND WHITE. 0C-61 BENJAMIN MOORE SPLIT FACE CMU LOW WALL . AC UNIT AC UNIT GRADE ADA ACCESSIBLE RAMP REFER TO MANUFACTURER PRODUCT APPROVAL DRAWINGS.3'-0"VARIESVARIES10'-11"ALL TRIMS PAINTED COLOR DIAMOND WHITE. 0C-61 BENJAMIN MOORE SYNTHETIC STUCCO WALLS PAINTED COLOR VAPOR. AF-35 BENJAMIN MOORE SINGLE PLY ROOFING COLOR WHITE 24"x54" 24"x54" GRADE ADA ACCESSIBLE RAMP REFER TO MANUFACTURER PRODUCT APPROVAL DRAWINGS.3'-0"VARIESVARIES10'-11"ALL TRIMS PAINTED COLOR DIAMOND WHITE. 0C-61 BENJAMIN MOORE ALUMINUM RAILING AS PART OF RAMP ASSEMBLY. SYNTHETIC STUCCO WALLS PAINTED COLOR VAPOR. AF-35 BENJAMIN MOORE SPLIT FACE CMU LOW WALL . SINGLE PLY ROOFING COLOR WHITE REVISIONS DRAWING NUMBER JOB NUMBER DATE DRAWING TITLE DRAWN BY CONSTRUCTION SEAL ISSUED FOR : BIDS PERMIT PROJECT TITLE THIS DOCUMENT IS THE PROPERTY OF CURRIE SOWARDS AGUILA ARCHITECTS INC. ALL RIGHTS ARE RESERVED. ANY POSSESSION, REPRODUCTION OR OTHER USE OF THIS DOCUMENT, WITHOUT THE WRITTEN CONSENT OF CURRIE SOWARDS AGUILA ARCHITECTS INC., IS PROHIBITED.Architecture, Planning, Interiors, & Sustainable Design AA26001584 185 NE 4TH AVENUE SUITE 101 DELRAY BEACH, FL 33483 THESE DRAWINGS ARE PREPARED PER ESTABLISHED INDUSTRY STANDARDS AND REPRESENT THE ARCHITECT AND ENGINEERS DESIGN CONCEPT. THEY ARE NOT INTENDED TO PROVIDE EVERY DETAIL OR CONDITION REQUIRED TO CONSTRUCT THE BUILDING. THE CONTRACTOR THROUGH SUBMITTALS AND OTHER COORDINATION EFFORTS IS FULLY RESPONSIBLE FOR PROVIDING A COMPLETE AND OPERATIONAL BUILDING WHETHER INDICATED ON THE PLANS OR NOT. T:(561) 276-4951 F:(561) 243-8184 E-MAIL: office@csa-architects.com SPA TENNIS FACILITIES RENOVATION HUNTERS RUN 3500 CLUBHOUSE LN. BOYNTON BEACH, FL 33436 07/03/23 FLEX SUB 07/24/2023DRC NUM.DESCRIPTION 220501 DATE PERMIT SETJT. 07/03/2023 A0.02 TENNIS BUILDING FLOOR PLAN & ELEVATIONS SCALE: TENNIS BUILDING AND RAMP FLOOR PLAN A A0.02 1/4" = 1'-0" SCALE: TENNIS BUILDING RAMP ELEVATION1 A0.02 1/4" = 1'-0" SCALE: TENNIS BUILDING ELEVATION2 A0.02 1/4" = 1'-0" SCALE: TENNIS BUILDING ELEVATION3 A0.02 1/4" = 1'-0" SCALE: TENNIS BUILDING ELEVATION4 A0.02 1/4" = 1'-0" SCALE: TENNIS BUILDING ELEVATION5 A0.02 1/4" = 1'-0" N CITY COMMENTS 2 08.15.23 2 2 3 3 3 3 3 3 P&Z COMMENTS 3 09.14.23 APPROVED APPROVED APPROVED APPROVED APPROVED APPROVED APPROVED APPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVED APPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVED Planning & Zoning Division September 25, 2023 Project #: ___________________________MMSP-2023.07.15798 REINFORCED CMU WALL SMOOTH STUCCO FINISH PAINTED COLOR VAPOR. AF-35 BENJAMIN MOORE 7'-0"CANOPY COLOR BLUE TO MATCH EXISTING 9'-378"GRADE GRADE GRADE CANOPY COLOR BLUE TO MATCH EXISTING CANOPY COLOR BLUE TO MATCH EXISTING CANOPY COLOR BLUE TO MATCH EXISTING 7'-0"3'-0"7'-0"3'-0"34" COUNTER H.BUILDING WALLS PAINTED COLOR VAPOR. AF-35 BENJAMIN MOORE REINFORCED CMU WALL SMOOTH STUCCO FINISH PAINTED COLOR VAPOR. AF-35 BENJAMIN MOORE GRADE BUILDING WALLS PAINTED COLOR VAPOR. AF-35 BENJAMIN MOORE BAND PAINTED COLOR DIAMOND WHITE. 0C-61 BENJAMIN MOORE SCORE LINESCORE LINEBAND PAINTED COLOR DIAMOND WHITE. 0C-61 BENJAMIN MOORE SCORE LINE BAND PAINTED COLOR DIAMOND WHITE. 0C-61 BENJAMIN MOORE BAND PAINTED COLOR DIAMOND WHITE. 0C-61 BENJAMIN MOORE SCORE LINE REINFORCED CMU WALL SMOOTH STUCCO FINISH PAINTED COLOR VAPOR. AF-35 BENJAMIN MOORE 15'-0"10"PAVED AREA CONCRETE SLAB ON GRADE WATER AND COFFEE DISPENSERS ON ADA ACCESSIBLE COUNTER. A0.04 2 A0.04 3 A0.04 13'-9"5'-5"10'-0"A0.04 4 HIDDEN NOTE DENOTES CANOPY. COLOR BLUE TO MATCH EXISTING REINFORCED CMU WALLS SMOOTH STUCCO FINISH PAINTED COLOR VAPOR. AF-35 BENJAMIN MOORE REVISIONS DRAWING NUMBER JOB NUMBER DATE DRAWING TITLE DRAWN BY CONSTRUCTION SEAL ISSUED FOR : BIDS PERMIT PROJECT TITLE THIS DOCUMENT IS THE PROPERTY OF CURRIE SOWARDS AGUILA ARCHITECTS INC. ALL RIGHTS ARE RESERVED. ANY POSSESSION, REPRODUCTION OR OTHER USE OF THIS DOCUMENT, WITHOUT THE WRITTEN CONSENT OF CURRIE SOWARDS AGUILA ARCHITECTS INC., IS PROHIBITED.Architecture, Planning, Interiors, & Sustainable Design AA26001584 185 NE 4TH AVENUE SUITE 101 DELRAY BEACH, FL 33483 THESE DRAWINGS ARE PREPARED PER ESTABLISHED INDUSTRY STANDARDS AND REPRESENT THE ARCHITECT AND ENGINEERS DESIGN CONCEPT. THEY ARE NOT INTENDED TO PROVIDE EVERY DETAIL OR CONDITION REQUIRED TO CONSTRUCT THE BUILDING. THE CONTRACTOR THROUGH SUBMITTALS AND OTHER COORDINATION EFFORTS IS FULLY RESPONSIBLE FOR PROVIDING A COMPLETE AND OPERATIONAL BUILDING WHETHER INDICATED ON THE PLANS OR NOT. T:(561) 276-4951 F:(561) 243-8184 E-MAIL: office@csa-architects.com SPA TENNIS FACILITIES RENOVATION HUNTERS RUN 3500 CLUBHOUSE LN. BOYNTON BEACH, FL 33436 07/03/23 FLEX SUB 07/24/2023DRC NUM.DESCRIPTION 220501 DATE PERMIT SETJT. 07/03/2023 A0.04 RESTROOM & BEVERAGE STATION FLOOR PLAN & ELEV. SCALE: BEVERAGE STATION ELEVATION2 A0.04 1/4" = 1'-0" SCALE: BEVERAGE STATION ELEVATION3 A0.04 1/4" = 1'-0" SCALE: BEVERAGE STATION FLOOR PLAN B A0.04 1/4" = 1'-0" N SCALE: BEVERAGE STATION ELEVATION2 A0.04 1/4" = 1'-0" SCALE: BEVERAGE STATION ELEVATION4 A0.04 1/4" = 1'-0" CITY COMMENTS 2 08.15.23 2 2 3 P&Z COMMENTS 3 09.20.23 3 3 3 3 3 3 3 APPROVED APPROVED APPROVED APPROVED APPROVED APPROVED APPROVED APPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVED APPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVED Planning & Zoning Division September 25, 2023 Project #: ___________________________MMSP-2023.07.15798 APPROVED APPROVED APPROVED APPROVED APPROVED APPROVED APPROVED APPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVED APPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVED Planning & Zoning Division September 25, 2023 Project #: ___________________________MMSP-2023.07.15798 Luminaire Schedule Symbol Qty Label Description LLF Lum. Watts Lum. Lumens 4 SA GARDCO#: ECF-S-32L-700-NW-G2-3 / MTD AT 12' AFG 0.900 72.9 9509 55 P HE WILLIAMS#: OSA6S-L10-835-AC / 38 INCH BOLLARD 0.900 11 956 161 T TOKISTAR #: UB-EX_IW_G19-C / MTD AT 10' AFG 0.900 1.8 49 Calculation Summary Label CalcType Units Avg Max Min Avg/Min Max/Min BOCCE COURT AREA Illuminance Fc 5.71 9.4 3.6 1.59 2.61 PATH AREAS Illuminance Fc 2.72 5.1 0.5 5.44 10.20 SEATING AREAS Illuminance Fc 1.29 4.2 0.7 1.84 6.00 P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T TTTTTTTTTTTTTTTT T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T T T T T T T T T T T T T T T T TTTTTTTTTT P P P P P P P P P P P P P SA SA SA SA P P P P 4.1 6.5 8.5 9.0 7.8 5.6 4.1 3.6 4.1 5.6 7.7 9.0 8.5 6.5 4.0 3.9 5.4 6.5 6.8 6.5 5.4 4.5 4.2 4.5 5.4 6.4 6.8 6.4 5.3 3.8 4.2 4.9 5.2 5.4 5.8 5.8 5.6 5.6 5.6 5.8 5.8 5.4 5.2 4.9 4.2 4.6 5.1 5.3 5.5 6.0 6.3 6.3 6.1 6.3 6.3 6.0 5.5 5.3 5.0 4.5 4.2 4.9 5.3 5.5 5.8 5.7 5.3 5.3 5.3 5.7 5.8 5.5 5.3 4.8 4.1 4.0 5.6 6.9 7.2 6.7 5.4 4.5 4.1 4.4 5.4 6.7 7.2 6.8 5.6 3.8 4.6 6.7 8.8 9.4 8.0 5.7 4.1 3.7 4.1 5.6 7.8 9.2 8.7 6.5 4.0 0.9 1.0 2.4 0.9 1.9 1.1 1.6 3.3 3.9 1.4 0.5 2.9 2.7 1.4 2.0 3.1 2.0 0.8 1.0 1.1 0.7 0.8 2.6 1.2 1.0 1.4 1.6 2.9 4.9 1.8 2.2 1.9 1.2 3.9 1.9 2.1 4.2 3.2 1.4 2.2 2.9 1.4 1.1 3.1 3.6 2.1 5.0 3.6 2.0 3.1 1.3 1.0 1.0 1.2 1.9 4.2 3.0 3.4 4.0 4.7 4.1 1.4 0.9 1.1 1.4 2.0 2.0 4.1 4.0 3.2 1.3 1.1 1.3 1.7 2.3 2.5 4.6 2.0 1.6 1.8 2.2 2.9 3.0 5.1 3.0 2.8 3.2 2.7 2.2 3.0 3.1 3.8 5.0 3.6 4.9 2.0 2.3 4.7 1.6 2.5 2.4 3.3 2.2 4.1 3.4 1.9 2.4 2.1 2.9 3.9 2.5 5.1 4.2 4.6 1.9 4.5 2.0 5.0 3.0 3.2 4.2 1.5 2.1 1.9 2.4 4.2 2.3 4.5 3.0 1.2 1.2 2.6 4.6 3.4 3.3 2.8 1.9 1.8 2.3 3.1 3.0 2.7 4.4 1.9 3.2 4.0 1.3 3.2 3.1 5.0 1.7 1.7 4.2 3.6 3.5 4.4 3.0 5.0 5.1 4.2 3.4 3.9 2.8 1.7 1.2 2.0 2.5 4.6 4.9 3.7 4.7 2.1 2.2 2.3 3.0 1.5 1.0 1.2 3.4 4.1 3.2 2.1 3.4 3.2 1.9 3.2 4.1 3.9 2.1 3.4 4.6 1.1 1.3 1.5 1.3 1.2 1.5 1.2 1.1 1.2 1.1 1.1 1.3 1.2 1.0 1.2 0.9 0.8 1.0 1.1 1.1 1.2 1.3 1.1 1.0 1.1 0.8 0.7 1.0 1.1 1.1 1.2 1.2 1.0 0.9 1.1 0.8 0.7 1.1 1.1 1.3 1.2 1.0 0.9 1.1 0.9 0.8 1.2 1.4 1.1 1.2 1.2 1.0 1.0 1.2 1.0 0.9 1.4 2.9 1.1 1.2 1.3 1.1 1.3 1.5 1.3 1.2 1.6 3.5 1.1 1.2 1.4 1.3 1.6 2.1 2.1 1.6 1.5 2.1 1.2 1.4 2.4 1.1 1.7 4.2 HUNTER'S RUN TENNIS FACILITY EXTERIOR LIGHTING REVISIONS DRAWING NUMBER JOB NUMBER DATE DRAWING TITLE DRAWN BY CONSTRUCTION SEAL ISSUED FOR : BIDS PERMIT PROJECT TITLE THIS DOCUMENT IS THE PROPERTY OF CURRIE SOWARDS AGUILA ARCHITECTS INC. ALL RIGHTS ARE RESERVED. ANY POSSESSION, REPRODUCTION OR OTHER USE OF THIS DOCUMENT, WITHOUT THE WRITTEN CONSENT OF CURRIE SOWARDS AGUILA ARCHITECTS INC., IS PROHIBITED.Architecture, Planning, Interiors, & Sustainable Design AA26001584 185 NE 4TH AVENUE SUITE 101 DELRAY BEACH, FL 33483 THESE DRAWINGS ARE PREPARED PER ESTABLISHED INDUSTRY STANDARDS AND REPRESENT THE ARCHITECT AND ENGINEERS DESIGN CONCEPT. THEY ARE NOT INTENDED TO PROVIDE EVERY DETAIL OR CONDITION REQUIRED TO CONSTRUCT THE BUILDING. THE CONTRACTOR THROUGH SUBMITTALS AND OTHER COORDINATION EFFORTS IS FULLY RESPONSIBLE FOR PROVIDING A COMPLETE AND OPERATIONAL BUILDING WHETHER INDICATED ON THE PLANS OR NOT. T:(561) 276-4951 F:(561) 243-8184 E-MAIL: office@csa-architects.com SPA TENNIS FACILITIES RENOVATION HUNTERS RUN 3500 CLUBHOUSE LN. BOYNTON BEACH, FL 33436 07/03/23 FLEX SUB 07/24/2023DRC NUM.DESCRIPTION 220501 DATE PERMIT SETJT. 07/03/2023 PM.01 PHOTOMETRICS SCALE: SITE PLAN PHOTOMETRIC1 PM.01 N.T.S. N TYPE "P"TYPE "T"TYPE "SA"TYPE "SA" POLE APPROVED APPROVED APPROVED APPROVED APPROVED APPROVED APPROVED APPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVED APPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVED Planning & Zoning Division September 25, 2023 Project #: ___________________________MMSP-2023.07.15798