Architectural Plans-FeedbackREVISIONS
DRAWING NUMBER
JOB NUMBER
DATE
DRAWING TITLE
DRAWN BY
CONSTRUCTION
SEAL
ISSUED FOR :
BIDS
PERMIT
PROJECT TITLE
THIS DOCUMENT IS THE PROPERTY OF CURRIE SOWARDS AGUILA ARCHITECTS INC. ALL RIGHTS ARE RESERVED. ANY POSSESSION, REPRODUCTION OR OTHER USE OF THIS DOCUMENT, WITHOUT THE WRITTEN CONSENT OF CURRIE SOWARDS AGUILA ARCHITECTS INC., IS PROHIBITED.Architecture, Planning,
Interiors, &
Sustainable Design
AA26001584
185 NE 4TH AVENUE SUITE 101
DELRAY BEACH, FL 33483
THESE DRAWINGS ARE PREPARED PER
ESTABLISHED INDUSTRY STANDARDS AND
REPRESENT THE ARCHITECT AND
ENGINEERS DESIGN CONCEPT. THEY ARE
NOT INTENDED TO PROVIDE EVERY
DETAIL OR CONDITION REQUIRED TO
CONSTRUCT THE BUILDING. THE
CONTRACTOR THROUGH SUBMITTALS
AND OTHER COORDINATION EFFORTS IS
FULLY RESPONSIBLE FOR PROVIDING A
COMPLETE AND OPERATIONAL BUILDING
WHETHER INDICATED ON THE PLANS OR
NOT.
T:(561) 276-4951 F:(561) 243-8184
E-MAIL: office@csa-architects.com
SPA
TENNIS FACILITIES
RENOVATION
HUNTERS RUN
3500 CLUBHOUSE LN.
BOYNTON BEACH, FL 33436
07/03/23
FLEX SUB
07/24/2023DRC
NUM.DESCRIPTION
220501
DATE
PERMIT SETJT.
07/03/2023
ARCHITECTURAL ABBREVIATIONS
LOCATION MAP
DETAIL NUMBER
DETAILED AREA
SHEET NUMBER
SECTION NUMBER
DETAIL NUMBER
SHEET NUMBER
SHEET NUMBER
SHEET NUMBER
ELEVATION
ELEVATION
ROOM NUMBER
SHEET NUMBER
HEIGHT ABOVE
FINISHED FLOOR
ARCHITECTURAL SYMBOLS
ALIGN W/ ESTABLISHED
SURFACE
DOOR NUMBER
WINDOW TYPE
WALL TYPE
A0.00
GENERAL NOTES
AND SYMBOLS
GENERAL NOTES
1.THIS PROJECT IS TO BE CONSTRUCTED UNDER THE PROVISIONS OF THE FLORIDA BUILDING CODE SEVENTH EDITION, FLORIDA
ACCESSIBILITY CODE 2020, NFPA 1 AND NFPA 101, ADA, FLORIDA STATE STATUTES AND ALL OTHER APPLICABLE CODES.
2.THE CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE HIMSELF WITH THE EXISTING CONDITIONS AND NOTIFY THE ARCHITECT OF
ANY OBSERVED DISCREPANCIES PRIOR TO SUBMISSION OF BIDS.
3.DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALE DIMENSIONS.
4.ANY WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED.
5.THESE DRAWINGS ARE DIAGRAMMATIC AND ARE INTENDED TO SHOW THE DESIGN INTENT ONLY. THEY DO NOT SHOW EVERY MINOR
DETAIL OF CONSTRUCTION. ALL TRADES ARE RESPONSIBLE FOR FURNISHING COMPLETE BUILDING SYSTEMS AND ALL ITEMS THAT WOULD
NORMALLY BE CONSIDERED INCIDENTAL TO THEIR INSTALLATION.
6.THE CONTRACTOR SHALL REVIEW THE PROJECT CONTRACT DOCUMENTS AND NOTIFY THE ARCHITECT OF ANY OBSERVED DISCREPANCIES
PRIOR TO START OF CONSTRUCTION.
7.ALL EXPOSED STUCCO, CEMENT, PLASTER OR GYPSUM BOARD SURFACES TO BE PAINTED UNLESS OTHERWISE NOTED. COLOR TO BE
SELECTED BY ARCHITECT. REFER TO SPECIFICATION FOR APPLICATION PROCEDURE.
8.ALL FIRE RATED WALLS AND PARTITIONS AND PARTITIONS INSULATED FOR SOUND TRANSMISSION ARE TO RUN CONTINUOUS FROM FLOOR
TO UNDERSIDE OF ROOF/FLOOR DECK ABOVE. ALL JOINTS TO BE TAPED AND SPACKLED AND ANY DUCT PENETRATIONS TO BE FIRE
DAMPERED AS REQUIRED BY CODE.
9.ALL CEMENT PLASTER OR PORTLAND CEMENT BOARD ABUTTING OTHER MATERIAL TO BE FINISHED WITH METAL EDGE STRIPS.
10.ALL ELECTRICAL CABINETS, FIRE EXTINGUISHERS, CABINETS AND OTHER RECESSED EQUIPMENT IN FIRE RATED WALLS SHALL BE BACKED
WITH 5/8" TYPE X GYPSUM BOARD OR AS REQUIRED TO MAINTAIN THE RATING.
11.PROVIDE DOUBLE STUDS OR WOOD BLOCKING AS REQUIRED TO SUPPORT WALL MOUNTED EQUIPMENT. BLOCKING IN CONTACT WITH
MASONRY/CONCRETE OR MOIST/HUMID CONDITIONS SHALL BE PRESSURE TREATED.
12.ALL EXPOSED METAL TO BE PAINTED. COLOR AS SELECTED BY THE ARCHITECT. REFER TO SPECIFICATION FOR APPLICATION PROCEDURE.
13.NO ASBESTOS IN ANY FORM WILL BE PERMITTED IN THIS BUILDING.
14.ALL DIMENSIONS SHOWN ON THIS PLAN ARE NOMINAL. THE CONTRACTOR SHALL BE RESPONSIBLE TO ADJUST ACTUAL CONSTRUCTION
DIMENSIONS SLIGHTLY TO ALLOW FOR EXACT MATERIAL THICKNESS AND REQUIRED CLEARANCE. DIMENSIONS ON PLANS ARE TO FINISH
OF INTERIOR STUD PARTITIONS, CENTERLINE OF CONSTRUCTION LINES, AND FACE OF MASONRY.
15.THE STRUCTURAL DRAWINGS SHALL TAKE PRECEDENCE OVER ARCHITECTURAL DRAWINGS WITH RESPECT TO COLUMN AND STRUCTURAL
ELEMENTS LOCATIONS. CONTRACTOR SHALL NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPENCIES.
16.IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND EACH OF HIS SUBCONTRACTORS TO REVIEW ALL DRAWINGS, PROJECT
MANUAL ADDENDA ETC. TO ASSURE COORDINATION OF ALL WORK AFFECTING EACH TRADE. FAILURE TO REVIEW ALL CONTRACT
DOCUMENTS FOR APPLICABLE ITEMS OF WORK SHALL NOT RELIEVE THE RESPONSIBLE PARTY FROM PERFORMING WORK SO REQUIRED.
WORK SHOWN ON ONE DRAWING IS AS GOOD AS IF SHOWN ON EVERY DRAWING.
17.EXISTING CONDITIONS- THE EXISTING SITE DIMENSIONS AND CONDITIONS SHOWN ON THESE DRAWINGS ARE ASSUMED TO BE ACCURATE
BASED ON AVAILABLE INFORMATION. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS ON THE JOB SITE AND NOTIFY THE
ARCHITECT OF DEVIATIONS FROM THESE DRAWINGS.
18.N.I.C. ITEMS- ALL ITEMS MARKED N.I.C. (NOT IN CONTRACT) ARE TO BE FURNISHED BY THE OWNER. CONSULT THE ARCHITECT FOR ANY
ADDITIONAL REQUIRED INFORMATION NOT SHOWN.
19.DUCTS, PIPES, CONDUIT, ETC.- ALL VERTICAL AND HORIZONTAL DUCTS, PIPES, CONDUIT, ETC. (WHETHER SHOWN OR NOT) IN FINISHED
ROOMS SHALL BE LOCATED IN WALL. ITEMS THAT CANNOT BE LOCATED IN WALL SHALL BE FURRED IN AND FINISHED TO MATCH ADJACENT
FINISHED SURFACES AND ANY REQUIRED WALL OR CEILING RATINGS. VERIFY ACCEPTABILITY WITH ARCHITECT PRIOR TO ENCASEMENT.
20.ACCESS PANELS: FURNISH AND INSTALL ACCESS PANELS, WHETHER SHOWN OR NOT, IN WALLS AND NON-ACCESSIBLE TYPE CEILINGS
WHERE SERVICE OR ADJUSTMENT TO MECHANICAL, FIRE PROTECTION, PLUMBING, OR ELECTRICAL EQUIPMENT IS REQUIRED.
21.FIXTURES, LAVATORIES AND SINKS SHALL BE INSTALLED A MINIMUM OF 4" FROM FINISHED SIDE WALLS. WATER CLOSETS SHALL BE
INSTALLED A MINIMUM OF 15" FROM FINISHED SIDE WALLS OR TOILET PARTITIONS TO CENTERLINE OF FIXTURE (18" TO CENTERLINE FOR
HANDICAP FIXTURES).
22.PRECAUTIONS: DO NOT PROCEED WITH WORK IF UNFORESEEN CONDITIONS ARE DISCOVERED WHICH COULD CAUSE ADVERSE EFFECTS
UPON THE STRUCTURE OR ITS OCCUPANTS. REPORT ANY SUCH CONDITION IMMEDIATELY TO THE ARCHITECT. TAKE PRECAUTIONS TO
PROPERLY SUPPORT THE STRUCTURE. THE CONTRACTOR SHALL REPORT ALL TOXIC MATERIALS LOCATED TO OWNER, ARCHITECT AND
AUTHORITIES HAVING JURISDICTION. REMOVAL OF MATERIAL WILL BE COMPLETED PER APPROVED MEANS BEFORE CONSTRUCTION
CONTINUES.
23.SAFETY: PROVIDE, ERECT AND MAINTAIN BARRICADES, LIGHTING AND GUARDRAILS AS REQUIRED BY APPLICABLE REGULATORY AGENCIES
TO PROTECT OCCUPANTS OF BUILDING AND WORKERS.
24.IF DISCREPANCIES EXIST BETWEEN SPECIFICATIONS AND DRAWINGS, THE MORE STRINGENT REQUIREMENT SHALL PREVAIL. NOTIFY THE
ARCHITECT OF ANY DISCREPANCIES TO OBTAIN CLARIFICATION.
25.EXIT ACCESS: MAINTAIN FREE, SAFE, AND APPROVED MEANS OF EGRESS IN AND OUT OF PROJECT LOCATION IN ACCORDANCE WITH
REQUIREMENTS OF APPLICABLE REGULATORY AGENCIES.
26.FINISHES: ALL FINISHES AND COLORS OF FIXTURES, EQUIPMENT, LIGHTS, DIFFUSERS, SINKS, PAINT, WALLCOVERINGS, ETC. SHALL BE
SELECTED BY ARCHITECT. SUBMIT FULL RANGE OF AVAILABLE FINISHES TO ARCHITECT FOR SELECTION. REFER TO FINISH SCHEDULE
AND NOTES.
27.STRUCTURAL REINFORCEMENT: IN THE EVENT THAT WINDOW OR STOREFRONT SIZES DICTATE THE NEED FOR ADDITIONAL STRUCTURAL
REINFORCEMENT, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE SUCH REINFORCEMENT DESIGNED BY A
REGISTERED ENGINEER AS PART OF THE WINDOW SYSTEM FOR NO ADDITIONAL COST.
28.PARTITIONS THAT ABUT THE STOREFRONT OR WINDOWS SHALL HAVE PAINTED ALUMINUM END CLOSURE.
29.THE GENERAL CONTRACTOR SHALL COORDINATE OPENINGS IN SLABS AND WALLS AS REQUIRED FOR THE INSTALLATION OF MECHANICAL,
ELECTRICAL, PLUMBING AND FIRE PROTECTION ITEMS. DO NOT CUT CONCRETE COLUMNS, BEAMS, OR OTHER STRUCTURAL ELEMENT
WITHOUT THE PRIOR WRITTEN PERMISSION OF THE STRUCTURAL ENGINEER OF RECORD.
30.SUPPLY AND RETURN REGISTERS IN CEILINGS SHALL BE INSTALLED OFFSET FROM ONE ANOTHER TO AVOID SOUND PASSAGE FROM ONE
ROOM TO ANOTHER. SOUND RATED ROOMS SHALL HAVE SOUND BOOTS INSTALLED IN THE DUCTWORK TO RESTRICT THE PASSAGE OF
SOUND.
31.CONTRACTOR SHALL HOLD A MEETING OF ALL SUB-CONTRACTORS WHO HAVE WORK THAT IS TO BE INSTALLED ABOVE THE CEILING PRIOR
TO THE START OF THEIR INSTALLATION FOR THE PURPOSE OF COORDINATING NECESSARY CLEARANCES AND PROPER ROUTING.
CONTRACTOR TO SUBMIT A TYPICAL SECTION DRAWN TO SCALE SHOWING THE ASSIGNED LAYERING.
32.CONTRACTOR SHALL CARRY BANDING, SCORE LINES, FINISHES ETC. AROUND EXTERIOR ARCHITECTURAL ELEMENTS SUCH AS COLUMNS,
ARCHES, SCREEN WALLS ETC. WHEN NO ELEVATION IS SHOWN FOR THOSE SIDE OR REAR ELEVATIONS.
33.WHERE A STUD WALL ABUTS A FURRED OUT MASONRY WALL THE CONTRACTOR SHALL HOLD THE FACE OF THE FURRING STRIP, SO THAT A
SMOOTH UNINTERRUPTED LAYER OF GYPSUM BOARD MAY BE APPLIED.
34.THE CONTRACTOR SHALL SELECT APPROPRIATE MATERIALS THAT ARE BEST SUITED FOR THEIR INTENDED USE.
35.THE GENERAL CONTRACTOR SHALL REVIEW WITH THE OWNER, ALL LIGHTING FIXTURES, PLUMBING FIXTURES AND DOOR HARDWARE
PRIOR TO ORDER PLACEMENT. IN THE EVENT THE OWNER IS NOT GIVEN THE OPPORTUNITY TO REVIEW AND APPROVE SAID FIXTURES, THE
ARCHITECT SHALL NOT BE HELD RESPONSIBLE FOR REPLACEMENT, RETURN OR RESTOCKING FEES ASSOCIATED WITH CORRECTING THE
ITEMS TO THE OWNER'S SATISFACTION.
36.ANY EXPOSED PLUMBING, ELECTRICAL OR FIRE SPRINKLER CONDUIT OR PIPING SHALL BE PAINTED TO MATCH ADJACENT SURFACES
UNLESS OTHERWISE NOTED.
37.WHEN STUCCO IS APPLIED TO A VERTICAL SURFACE, THE CONTRACTOR SHALL INSTALL STUCCO CONTROL JOINTS AS INDICATED IN THE
CONTRACT DOCUMENTS AND AS OTHERWISE NECESSARY ON A REGULAR GRID NOT EXCEEDING 140 SF, AS APPROVED BY THE ARCHITECT.
38.WHEN STUCCO IS APPLIED TO A HORIZONTAL SURFACE, THE CONTRACTOR SHALL INSTALL STUCCO CONTROL JOINTS AS INDICATED IN
THE CONTRACT DOCUMENTS AND AS OTHERWISE NECESSARY ON A REGULAR GRID NOT EXCEEDING 100 SF, AS APPROVED BY THE
ARCHITECT.
39.THE ARCHITECTURAL DRAWINGS ARE PART OF THE CONTRACT DOCUMENTS AND DO NOT, BY THEMSELVES, PROVIDE ALL THE
INFORMATION REQUIRED TO PROPERLY CONSTRUCT THE PROJECT. THE GENERAL CONTRACTOR SHALL CONSULT THE STRUCTURAL,
MECHANICAL, ELECTRICAL, PLUMBING, FIRE PROTECTION, CIVIL, LANDSCAPING, AND SPECIALTY CONSULTANT'S DRAWINGS AND
COORDINATE THE INFORMATION CONTAINED IN THOSE DRAWINGS WITH THE ARCHITECTURAL DRAWINGS TO PROPERLY CONSTRUCT THE
PROJECT. REFER TO MECHANICAL, ELECTRICAL, PLUMBING AND STRUCTURAL FOR ADDITIONAL OPENINGS, DEPRESSIONS, PENETRATIONS,
INSERTS, DRAINS, ETC. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT, BEFORE PROCEEDING WITH ANY
WORK. THIS COORDINATION IS THE CONTRACTORS RESPONSIBILITY, AND NO EXTRA COMPENSATION WILL BE ALLOWED RESULTING FROM
THE CONTRACTORS FAILURE TO COMPLY WITH THESE REQUIREMENTS.
SITE PLAN PROPOSAL AFTER DEMOLITION OF THE CURRENT TENNIS FACILITY AND ADJACENT PLATFORM.
PROJECT SCOPE OF WORK
CURRIE SOWARDS AGUILA ARCHITECTS
ARCHITECT :
185 NE 4th Avenue
Suite 101
Delray Beach, FL 33483
TEL: 561-276-4951
FAX: 561-243-8184
OWNER :
HUNTERS RUN PROPERTY
OWNERS ASSOC INC
COMMUNITY MGMT OFFICE (CMO)
C/O 3500 CLUBHOUSE LN3825
BOYNTON BEACH FL 33436 6002
HUNTERS RUN TENNIS
FACILITIES RENOVATION
3500 CLUBHOUSE LN,
BOYNTON BEACH, FL 33436
HUNTERS RUN COUNTRY CLUB
**THIS PROJECT WAS CONSTRUCTED UNDER THE 2004 FLORIDA BUILDING CODE, FLORIDA FIRE
PREVENTION CODE (FFPC) 2004 EDITION WITH BROWARD COUNTY AMENDMENTS WHICH INCLUDES NFPA
101, 2003 EDITION, NFPA 1, 2003, & STATE STATUTES, 2003 EDITION.
PROJECT INFORMATION
PROJECT ADDRESS:
SCOPE OF WORK:
EXISTING BUILDING AREA:
ZONING:
TYPE OF USE:
TYPE OF OCCUPANCY:
TYPE OF CONSTRUCTION:
ALTERATION TYPE:
APPLICABLE CODES
ARCHITECTURE:
ELECTRICAL/FIRE:
PLUMBING/MECHANICAL:
3500 CLUBHOUSE LN, BOYNTON BEACH, FL 33436
SITE PLAN PROPOSAL AFTER DEMOLITION OF THE CURRENT TENNIS
FACILITY AND ADJACENT PLATFORM. (6,480 S.F.)
INFILL PLANNED UNIT DEVELOPMENT ASSEMBLY
RESIDENTIAL / CLUBHOUSE
(A-2)
TYPE II-B (MASONRY NON COMBUSTIBLE)
N/A - DEMOLITION
FLORIDA BUILDING CODE EXISTING 2020, FLORIDA BUILDING CODE
2020 AND 2020 FLORIDA ACCESSIBILTY CODE
NFPA 70, NATIONAL ELECTRICAL CODE, FLORIDA FIRE PREVENTION
CODE 2020 ADDITION,NFPA 101 LIFE SAFETY CODE
FLORIDA BUILDING CODE PLUMBING 2020 EDITION
FLORIDA BUILDING CODE MECHANICAL 2020 EDITION
SCOPE OF WORK LOCATION
SITE
SPACE
LOCATION
SHEET INDEX
SHEET #SHEET TITLE LAST REVISED
ARCHITECTURAL
COVERSHEET
TENNIS BUILDING FLOOR PLAN & ELEVATIONS
08/15/23
A0.02
A0.00
REVISION #
2
BEVERAGE STATION FLOOR PLAN & ELEV. A0.04
ARCHITECTURAL SITE PLAN A0.01
SITE PLAN PHOTOMETRICSPM.01
08/15/232
09/20/233
08/15/232
TENNIS BUILDING COLOR ELEV. (New Sheet) A0.05 3 09/20/23
3
APPROVED APPROVED APPROVED APPROVED APPROVED APPROVED APPROVED APPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVED
APPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVED
Planning & Zoning Division
September 25, 2023
Project #: ___________________________MMSP-2023.07.15798
10' CLF
10' CLF
SAND
TRAP
10' CLF
10' CLF
EXISTING OAK TREES TO
REMAIN (TYP)
EXISTING
TENNIS
COURT
EXISTING
TENNIS
COURT
CONCRETE
SIDEWALK
EXISTING
CART
PARKING
119'FPLUE
EAST TRACT 21 LINESAND
TRAP
SAND
TRAP
120' FPL UE
SOUTHEASTERLY TRACT 21 LINEMAINTENANCE SHED
8'X20'
EXISTING
PARKING AREA
BEVERAGE STATION
10' x 15'
EXISTING
TENNIS
COURT
EXISTING
TENNIS
COURT
BOCCE
COURT
EXISTING
TENNIS
COURT
EXISTING
TENNIS
COURT
EXISTING
TENNIS
COURT
EXISTING
PARKING AREA TO BE
USED FOR TENNIS
FACILITIES
72'
EXISTING
TENNIS
COURT
EXISTING
TENNIS
COURT
L.A.
L.A.
L.A.
L.A.
EXISTING WATER STATION
SEE ADA RAMP
DRAWINGS BY
MANUFACTURER
RECREATION
TRACT 21
SUMMIT PLAT 1
SOUTH TRACT 21 LINE
120' FPL UE
10
10
1212
9
18
EX. FIRE HYDRANT
L.A.
L.A.
SHADE
STRUCTURE
16' x 62'
SHADE
STRUCTURE
30' x 50'
EXISTING
CART PATH
TRACT 12
SUMMIT PLAT 1
PCN: 08-42-46-01-04-000-0010
TRACT 12
SUMMIT PLAT 1
PCN: 08-42-46-01-04-000-0010
EXISTING
CART PATH
BOCCE
COURT
TURF
L.A.
TURF
TURF
L.A.
TENNIS
BUILDING "A"
24'X56'
SOFT SEATING /
BBQ AREA
A0.02
A
A0.04
B
REVISIONS
DRAWING NUMBER
JOB NUMBER
DATE
DRAWING TITLE
DRAWN BY
CONSTRUCTION
SEAL
ISSUED FOR :
BIDS
PERMIT
PROJECT TITLE
THIS DOCUMENT IS THE PROPERTY OF CURRIE SOWARDS AGUILA ARCHITECTS INC. ALL RIGHTS ARE RESERVED. ANY POSSESSION, REPRODUCTION OR OTHER USE OF THIS DOCUMENT, WITHOUT THE WRITTEN CONSENT OF CURRIE SOWARDS AGUILA ARCHITECTS INC., IS PROHIBITED.Architecture, Planning,
Interiors, &
Sustainable Design
AA26001584
185 NE 4TH AVENUE SUITE 101
DELRAY BEACH, FL 33483
THESE DRAWINGS ARE PREPARED PER
ESTABLISHED INDUSTRY STANDARDS AND
REPRESENT THE ARCHITECT AND
ENGINEERS DESIGN CONCEPT. THEY ARE
NOT INTENDED TO PROVIDE EVERY
DETAIL OR CONDITION REQUIRED TO
CONSTRUCT THE BUILDING. THE
CONTRACTOR THROUGH SUBMITTALS
AND OTHER COORDINATION EFFORTS IS
FULLY RESPONSIBLE FOR PROVIDING A
COMPLETE AND OPERATIONAL BUILDING
WHETHER INDICATED ON THE PLANS OR
NOT.
T:(561) 276-4951 F:(561) 243-8184
E-MAIL: office@csa-architects.com
SPA
TENNIS FACILITIES
RENOVATION
HUNTERS RUN
3500 CLUBHOUSE LN.
BOYNTON BEACH, FL 33436
07/03/23
FLEX SUB
07/24/2023DRC
NUM.DESCRIPTION
220501
DATE
PERMIT SETJT.
07/03/2023
A0.01
ARCHITECTURAL
SITE PLAN
SCALE:
SITE PLAN1
A1.01 1" = 30'
N
CITY COMMENTS 2 08.15.23
2
APPROVED APPROVED APPROVED APPROVED APPROVED APPROVED APPROVED APPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVED
APPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVED
Planning & Zoning Division
September 25, 2023
Project #: ___________________________MMSP-2023.07.15798
24"x54"
56'-0"23'-4"24"x54" 24"x54" 24"x54"
24"x54" 24"x54" 24"x54" 24"x54" 24"x54" Ø5'-0"Ø5'
-0
"Ø5'-0"36"x80"
36"x80"
36"x80"
36"x80"36"x80"36"x80"ADA RESTROOMS
REFER TO MANUFACTURER
PRODUCT APPROVAL
DRAWINGS.
12'-0" RAMP 1:12 6'-0" LANDING 12'-0" RAMP 1:12
LANDING
8'-0"4'-0"4'-0"72"x80"
UP.SLOPED
PAVED AREA
UP.
A0.02
2
A0.02
1
STRUCTURE TO BE PERMANENTLY
ATTACHED AND SECURE TO GROUND
REFER TO MANUFACTURER AND
PRODUCT APPROVAL DRAWINGS DETAILS.
A0.02
3
A0.02
5
A0.02
4
8'-0"AC UNIT AC UNIT ADA COUNTER ACCESSIBLE
REFER TO MANUFACTURER
PRODUCT APPROVAL
DRAWINGS.
ADA ACCESSIBLE RAMP
REFER TO MANUFACTURER
PRODUCT APPROVAL
DRAWINGS.
FIRE EXTINGUISHER.
ABC MULTIPURPOSE DRY CHEMICAL
5 LBS.
UL APPROVED 2:A 10:B C
HOSE DISCHARGE.
OCCUPANCY DATA
- OCCUPANCY: B (BUSINESS)
- OCCUPANT LOAD : 9 (AS PER 7.3.1.2)
SPLIT FACE
CMU LOW WALL .
SPLIT FACE
CMU LOW WALL .2'-6"VERIFY2'-0"1'-0"
SLOPED
PAVED AREA
ADA ACCESSIBLE RAMP
REFER TO MANUFACTURER
PRODUCT APPROVAL
DRAWINGS.3'-0"24"x54" 24"x54"
24"x54" 24"x54" 24"x54" 24"x54"
24"x54"
72"x80"10'-4"7"VARIES10'-11"10'-4"7"VARIES10'-11"GRADE
GRADE
DOOR AND TRIM PAINTED
COLOR DIAMOND WHITE.
0C-61 BENJAMIN MOORE
SPLIT FACE
CMU LOW WALL .
ALL TRIMS PAINTED COLOR
DIAMOND WHITE.
0C-61
BENJAMIN MOORE
SINGLE PLY ROOFING
COLOR WHITE
SYNTHETIC STUCCO WALLS
PAINTED COLOR VAPOR.
AF-35
BENJAMIN MOORE
ALL TRIMS PAINTED COLOR
DIAMOND WHITE.
0C-61
BENJAMIN MOORE
SYNTHETIC STUCCO WALLS
PAINTED COLOR VAPOR.
AF-35
BENJAMIN MOORE
SINGLE PLY ROOFING
COLOR WHITE
ALL TRIMS PAINTED COLOR
DIAMOND WHITE.
0C-61
BENJAMIN MOORE
SPLIT FACE CMU LOW WALL .
AC UNIT AC UNIT
GRADE
ADA ACCESSIBLE RAMP
REFER TO MANUFACTURER
PRODUCT APPROVAL
DRAWINGS.3'-0"VARIESVARIES10'-11"ALL TRIMS PAINTED COLOR
DIAMOND WHITE.
0C-61
BENJAMIN MOORE
SYNTHETIC STUCCO WALLS
PAINTED COLOR VAPOR.
AF-35
BENJAMIN MOORE
SINGLE PLY ROOFING
COLOR WHITE
24"x54" 24"x54"
GRADE
ADA ACCESSIBLE RAMP
REFER TO MANUFACTURER
PRODUCT APPROVAL
DRAWINGS.3'-0"VARIESVARIES10'-11"ALL TRIMS PAINTED COLOR
DIAMOND WHITE.
0C-61
BENJAMIN MOORE
ALUMINUM RAILING
AS PART OF RAMP
ASSEMBLY.
SYNTHETIC STUCCO WALLS
PAINTED COLOR VAPOR.
AF-35
BENJAMIN MOORE
SPLIT FACE CMU LOW WALL .
SINGLE PLY ROOFING
COLOR WHITE
REVISIONS
DRAWING NUMBER
JOB NUMBER
DATE
DRAWING TITLE
DRAWN BY
CONSTRUCTION
SEAL
ISSUED FOR :
BIDS
PERMIT
PROJECT TITLE
THIS DOCUMENT IS THE PROPERTY OF CURRIE SOWARDS AGUILA ARCHITECTS INC. ALL RIGHTS ARE RESERVED. ANY POSSESSION, REPRODUCTION OR OTHER USE OF THIS DOCUMENT, WITHOUT THE WRITTEN CONSENT OF CURRIE SOWARDS AGUILA ARCHITECTS INC., IS PROHIBITED.Architecture, Planning,
Interiors, &
Sustainable Design
AA26001584
185 NE 4TH AVENUE SUITE 101
DELRAY BEACH, FL 33483
THESE DRAWINGS ARE PREPARED PER
ESTABLISHED INDUSTRY STANDARDS AND
REPRESENT THE ARCHITECT AND
ENGINEERS DESIGN CONCEPT. THEY ARE
NOT INTENDED TO PROVIDE EVERY
DETAIL OR CONDITION REQUIRED TO
CONSTRUCT THE BUILDING. THE
CONTRACTOR THROUGH SUBMITTALS
AND OTHER COORDINATION EFFORTS IS
FULLY RESPONSIBLE FOR PROVIDING A
COMPLETE AND OPERATIONAL BUILDING
WHETHER INDICATED ON THE PLANS OR
NOT.
T:(561) 276-4951 F:(561) 243-8184
E-MAIL: office@csa-architects.com
SPA
TENNIS FACILITIES
RENOVATION
HUNTERS RUN
3500 CLUBHOUSE LN.
BOYNTON BEACH, FL 33436
07/03/23
FLEX SUB
07/24/2023DRC
NUM.DESCRIPTION
220501
DATE
PERMIT SETJT.
07/03/2023
A0.02
TENNIS BUILDING
FLOOR PLAN &
ELEVATIONS
SCALE:
TENNIS BUILDING AND RAMP FLOOR PLAN A
A0.02 1/4" = 1'-0"
SCALE:
TENNIS BUILDING RAMP ELEVATION1
A0.02 1/4" = 1'-0"
SCALE:
TENNIS BUILDING ELEVATION2
A0.02 1/4" = 1'-0"
SCALE:
TENNIS BUILDING ELEVATION3
A0.02 1/4" = 1'-0"
SCALE:
TENNIS BUILDING ELEVATION4
A0.02 1/4" = 1'-0"
SCALE:
TENNIS BUILDING ELEVATION5
A0.02 1/4" = 1'-0"
N
CITY COMMENTS 2 08.15.23
2
2
3
3
3
3
3
3 P&Z COMMENTS 3 09.14.23
APPROVED APPROVED APPROVED APPROVED APPROVED APPROVED APPROVED APPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVED
APPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVED
Planning & Zoning Division
September 25, 2023
Project #: ___________________________MMSP-2023.07.15798
REINFORCED CMU WALL
SMOOTH STUCCO FINISH
PAINTED COLOR VAPOR.
AF-35
BENJAMIN MOORE 7'-0"CANOPY COLOR BLUE
TO MATCH EXISTING
9'-378"GRADE
GRADE GRADE
CANOPY COLOR BLUE
TO MATCH EXISTING
CANOPY COLOR BLUE
TO MATCH EXISTING
CANOPY COLOR BLUE
TO MATCH EXISTING
7'-0"3'-0"7'-0"3'-0"34" COUNTER H.BUILDING WALLS
PAINTED COLOR VAPOR.
AF-35
BENJAMIN MOORE
REINFORCED CMU WALL
SMOOTH STUCCO FINISH
PAINTED COLOR VAPOR.
AF-35
BENJAMIN MOORE
GRADE
BUILDING WALLS
PAINTED COLOR VAPOR.
AF-35
BENJAMIN MOORE
BAND PAINTED COLOR
DIAMOND WHITE.
0C-61
BENJAMIN MOORE
SCORE LINESCORE LINEBAND PAINTED COLOR
DIAMOND WHITE.
0C-61
BENJAMIN MOORE
SCORE LINE BAND PAINTED COLOR
DIAMOND WHITE.
0C-61
BENJAMIN MOORE
BAND PAINTED COLOR
DIAMOND WHITE.
0C-61
BENJAMIN MOORE
SCORE LINE
REINFORCED CMU WALL
SMOOTH STUCCO FINISH
PAINTED COLOR VAPOR.
AF-35
BENJAMIN MOORE
15'-0"10"PAVED AREA
CONCRETE SLAB
ON GRADE
WATER AND COFFEE
DISPENSERS ON ADA
ACCESSIBLE COUNTER.
A0.04
2
A0.04
3
A0.04
13'-9"5'-5"10'-0"A0.04
4
HIDDEN NOTE DENOTES
CANOPY. COLOR BLUE
TO MATCH EXISTING
REINFORCED CMU WALLS
SMOOTH STUCCO FINISH
PAINTED COLOR VAPOR.
AF-35
BENJAMIN MOORE
REVISIONS
DRAWING NUMBER
JOB NUMBER
DATE
DRAWING TITLE
DRAWN BY
CONSTRUCTION
SEAL
ISSUED FOR :
BIDS
PERMIT
PROJECT TITLE
THIS DOCUMENT IS THE PROPERTY OF CURRIE SOWARDS AGUILA ARCHITECTS INC. ALL RIGHTS ARE RESERVED. ANY POSSESSION, REPRODUCTION OR OTHER USE OF THIS DOCUMENT, WITHOUT THE WRITTEN CONSENT OF CURRIE SOWARDS AGUILA ARCHITECTS INC., IS PROHIBITED.Architecture, Planning,
Interiors, &
Sustainable Design
AA26001584
185 NE 4TH AVENUE SUITE 101
DELRAY BEACH, FL 33483
THESE DRAWINGS ARE PREPARED PER
ESTABLISHED INDUSTRY STANDARDS AND
REPRESENT THE ARCHITECT AND
ENGINEERS DESIGN CONCEPT. THEY ARE
NOT INTENDED TO PROVIDE EVERY
DETAIL OR CONDITION REQUIRED TO
CONSTRUCT THE BUILDING. THE
CONTRACTOR THROUGH SUBMITTALS
AND OTHER COORDINATION EFFORTS IS
FULLY RESPONSIBLE FOR PROVIDING A
COMPLETE AND OPERATIONAL BUILDING
WHETHER INDICATED ON THE PLANS OR
NOT.
T:(561) 276-4951 F:(561) 243-8184
E-MAIL: office@csa-architects.com
SPA
TENNIS FACILITIES
RENOVATION
HUNTERS RUN
3500 CLUBHOUSE LN.
BOYNTON BEACH, FL 33436
07/03/23
FLEX SUB
07/24/2023DRC
NUM.DESCRIPTION
220501
DATE
PERMIT SETJT.
07/03/2023
A0.04
RESTROOM &
BEVERAGE STATION
FLOOR PLAN &
ELEV.
SCALE:
BEVERAGE STATION ELEVATION2
A0.04 1/4" = 1'-0"
SCALE:
BEVERAGE STATION ELEVATION3
A0.04 1/4" = 1'-0"
SCALE:
BEVERAGE STATION FLOOR PLAN B
A0.04 1/4" = 1'-0"
N
SCALE:
BEVERAGE STATION ELEVATION2
A0.04 1/4" = 1'-0"
SCALE:
BEVERAGE STATION ELEVATION4
A0.04 1/4" = 1'-0"
CITY COMMENTS 2 08.15.23
2
2
3
P&Z COMMENTS 3 09.20.23
3
3
3
3
3 3
3
APPROVED APPROVED APPROVED APPROVED APPROVED APPROVED APPROVED APPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVED
APPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVED
Planning & Zoning Division
September 25, 2023
Project #: ___________________________MMSP-2023.07.15798
APPROVED APPROVED APPROVED APPROVED APPROVED APPROVED APPROVED APPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVED
APPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVED
Planning & Zoning Division
September 25, 2023
Project #: ___________________________MMSP-2023.07.15798
Luminaire Schedule
Symbol Qty Label Description LLF Lum. Watts Lum. Lumens
4 SA GARDCO#: ECF-S-32L-700-NW-G2-3 / MTD AT 12' AFG 0.900 72.9 9509
55 P HE WILLIAMS#: OSA6S-L10-835-AC / 38 INCH BOLLARD 0.900 11 956
161 T TOKISTAR #: UB-EX_IW_G19-C / MTD AT 10' AFG 0.900 1.8 49
Calculation Summary
Label CalcType Units Avg Max Min Avg/Min Max/Min
BOCCE COURT AREA Illuminance Fc 5.71 9.4 3.6 1.59 2.61
PATH AREAS Illuminance Fc 2.72 5.1 0.5 5.44 10.20
SEATING AREAS Illuminance Fc 1.29 4.2 0.7 1.84 6.00
P
P
P
P
P
P
P
P
P
P
P
P P
P
P
P
P
P
P
P
P P
P
P
P
P P
P
P
P
P
P
P
P
P
P
P P
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T T
T T T T T T T T T T T T T
T T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
TTTTTTTTTTTTTTTT
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T T T T T T T T
TT
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
TTTTTTTTTT
P
P
P
P
P
P
P
P
P
P
P
P
P SA SA
SA SA
P
P
P
P
4.1 6.5 8.5 9.0 7.8 5.6 4.1 3.6 4.1 5.6 7.7 9.0 8.5 6.5 4.0
3.9 5.4 6.5 6.8 6.5 5.4 4.5 4.2 4.5 5.4 6.4 6.8 6.4 5.3 3.8
4.2 4.9 5.2 5.4 5.8 5.8 5.6 5.6 5.6 5.8 5.8 5.4 5.2 4.9 4.2
4.6 5.1 5.3 5.5 6.0 6.3 6.3 6.1 6.3 6.3 6.0 5.5 5.3 5.0 4.5
4.2 4.9 5.3 5.5 5.8 5.7 5.3 5.3 5.3 5.7 5.8 5.5 5.3 4.8 4.1
4.0 5.6 6.9 7.2 6.7 5.4 4.5 4.1 4.4 5.4 6.7 7.2 6.8 5.6 3.8
4.6 6.7 8.8 9.4 8.0 5.7 4.1 3.7 4.1 5.6 7.8 9.2 8.7 6.5 4.0
0.9 1.0 2.4
0.9 1.9
1.1 1.6 3.3 3.9 1.4 0.5
2.9 2.7 1.4 2.0 3.1 2.0 0.8 1.0 1.1 0.7 0.8
2.6 1.2 1.0 1.4 1.6 2.9 4.9 1.8 2.2
1.9 1.2 3.9
1.9 2.1 4.2 3.2 1.4 2.2 2.9 1.4 1.1 3.1
3.6 2.1 5.0 3.6 2.0 3.1 1.3 1.0 1.0 1.2 1.9
4.2 3.0 3.4 4.0 4.7 4.1 1.4 0.9 1.1 1.4 2.0
2.0 4.1 4.0 3.2 1.3 1.1 1.3 1.7 2.3
2.5 4.6 2.0 1.6 1.8 2.2 2.9
3.0 5.1 3.0 2.8 3.2
2.7 2.2 3.0 3.1 3.8
5.0 3.6 4.9 2.0 2.3 4.7
1.6 2.5 2.4 3.3 2.2 4.1 3.4
1.9 2.4 2.1 2.9 3.9 2.5 5.1 4.2
4.6 1.9 4.5 2.0 5.0 3.0 3.2 4.2 1.5 2.1 1.9 2.4 4.2 2.3 4.5 3.0 1.2 1.2 2.6 4.6 3.4 3.3 2.8 1.9
1.8 2.3 3.1 3.0 2.7 4.4 1.9 3.2 4.0 1.3 3.2 3.1 5.0 1.7 1.7 4.2 3.6 3.5 4.4 3.0 5.0 5.1 4.2
3.4 3.9 2.8 1.7 1.2
2.0 2.5 4.6
4.9 3.7 4.7 2.1 2.2
2.3 3.0 1.5 1.0 1.2 3.4 4.1 3.2 2.1 3.4 3.2 1.9
3.2 4.1 3.9 2.1 3.4
4.6
1.1 1.3 1.5 1.3 1.2 1.5 1.2 1.1 1.2
1.1 1.1 1.3 1.2 1.0 1.2 0.9 0.8 1.0 1.1
1.1 1.2 1.3 1.1 1.0 1.1 0.8 0.7 1.0 1.1
1.1 1.2 1.2 1.0 0.9 1.1 0.8 0.7 1.1
1.1 1.3 1.2 1.0 0.9 1.1 0.9 0.8 1.2 1.4
1.1 1.2 1.2 1.0 1.0 1.2 1.0 0.9 1.4 2.9
1.1 1.2 1.3 1.1 1.3 1.5 1.3 1.2 1.6 3.5
1.1 1.2 1.4 1.3 1.6 2.1 2.1 1.6 1.5 2.1
1.2 1.4 2.4
1.1 1.7 4.2
HUNTER'S RUN
TENNIS FACILITY
EXTERIOR LIGHTING
REVISIONS
DRAWING NUMBER
JOB NUMBER
DATE
DRAWING TITLE
DRAWN BY
CONSTRUCTION
SEAL
ISSUED FOR :
BIDS
PERMIT
PROJECT TITLE
THIS DOCUMENT IS THE PROPERTY OF CURRIE SOWARDS AGUILA ARCHITECTS INC. ALL RIGHTS ARE RESERVED. ANY POSSESSION, REPRODUCTION OR OTHER USE OF THIS DOCUMENT, WITHOUT THE WRITTEN CONSENT OF CURRIE SOWARDS AGUILA ARCHITECTS INC., IS PROHIBITED.Architecture, Planning,
Interiors, &
Sustainable Design
AA26001584
185 NE 4TH AVENUE SUITE 101
DELRAY BEACH, FL 33483
THESE DRAWINGS ARE PREPARED PER
ESTABLISHED INDUSTRY STANDARDS AND
REPRESENT THE ARCHITECT AND
ENGINEERS DESIGN CONCEPT. THEY ARE
NOT INTENDED TO PROVIDE EVERY
DETAIL OR CONDITION REQUIRED TO
CONSTRUCT THE BUILDING. THE
CONTRACTOR THROUGH SUBMITTALS
AND OTHER COORDINATION EFFORTS IS
FULLY RESPONSIBLE FOR PROVIDING A
COMPLETE AND OPERATIONAL BUILDING
WHETHER INDICATED ON THE PLANS OR
NOT.
T:(561) 276-4951 F:(561) 243-8184
E-MAIL: office@csa-architects.com
SPA
TENNIS FACILITIES
RENOVATION
HUNTERS RUN
3500 CLUBHOUSE LN.
BOYNTON BEACH, FL 33436
07/03/23
FLEX SUB
07/24/2023DRC
NUM.DESCRIPTION
220501
DATE
PERMIT SETJT.
07/03/2023
PM.01
PHOTOMETRICS
SCALE:
SITE PLAN PHOTOMETRIC1
PM.01 N.T.S.
N
TYPE "P"TYPE "T"TYPE "SA"TYPE "SA" POLE
APPROVED APPROVED APPROVED APPROVED APPROVED APPROVED APPROVED APPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVED
APPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVED
Planning & Zoning Division
September 25, 2023
Project #: ___________________________MMSP-2023.07.15798