Electrical Set - Rev1 (1)1 LIGHTING PLAN
1/4" = 1'-0"NOTE:
GENERAL NOTES:LIGHTING SCHEDULE
CEILING LEGEND
MUSIC SYSTEM NOTES:
THE MUSIC SYSTEM IS A REQUIREMENT OF THE BRAND AND
NO LONGER OPTIONAL. ARCHITECTS TO UPDATE
ARCHITECTURAL DRAWINGS PER GUIDELINES DIRECTLY
BELOW.
1.MUSIC SYSTEM IS REQUIRED IN ALL NEW AND REMODEL
STORES. MUSIC SYSTEM TO USE DBI APPROVED
PROGRAMMING
2.ALL CEILING SPEAKERS TO BE FLUSH MOUNTED WHITE.
ALL EXTERIOR SPEAKERS TO BE BLACK, WITH EXTERIOR
GRADE CONSTRUCTION.
3.ONE SPEAKER IN EACH BATHROOM TO BE FLUSH
MOUNTED WHITE.
4.A MINIMUM OF TWO SPEAKERS IN THE SEATING AREA
(NO SPEAKERS IN THE SERVICE AREA).
5.A MINIMUM OF TWO SPEAKERS AT EXTERIOR SEATING
AREAS WHERE APPLICABLE.
6.SPEAKER AT EXTERIOR OF BUILDING ADJACENT TO
ENTRY.
7.PROVIDE AND INSTALL SEPARATE VOLUME CONTROLS
FOR EACH AREA (RESTROOMS, SEATING AREA,
EXTERIOR)
8.HARDWARE TO BE INSTALLED IN THE OFFICE. FIELD
VERIFY AND COORDINATE WITH FRANCHISE FOR THE
EXACT LOCATION OF THE UNIT AND VOLUME CONTROLS.
KEYED NOTES:
1.INTERLOCK TOILET ROOM LIGHT WITH EXHAUST FAN.
2.PROVIDE SWITCHES WITH PILOT LIGHTS FOR WALK-IN REFRIGERATOR AND FREEZER.
3.CIRCUIT EXTERIOR SIGNS THROUGH TIMECLOCK. VERIFY QUANTITY AND LOCATION WITH
ARCHITECTURAL DRAWINGS.
4.SPEAKER AND SOUND SYSTEM TO BE PROVIDED AND INSTALLED BY ELECTRICAL
CONTRACTOR. LOCATE VOLUME CONTROL IN THE OFFICE. SEE ARCHITECTURAL CEILING
PLAN FOR EXACT LOCATION AND CONTROL.
5.ALL EXIT/EMERGENCY LIGHTS TO BE AHEAD OF SWITCH.
A.ALL WORK SHALL COMPLY WITH ALL LOCAL AND STATE CODES AND AUTHORITIES HAVING JURISDICTION.
B.THE CONTRACTOR SHALL SECURE AND PAY FOR ALL REQUIRED PERMITS AND ARRANGE ALL REQUIRED INSPECTIONS.
C.THE CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER CONTRACTORS AND TRADES.
D.THESE DRAWINGS, AS PREPARED, ARE DIAGRAMMATIC BUT SHALL BE FOLLOWED AS CLOSELY AS CONSTRUCTION OF
THE PROJECT AND THE WORK OF THE TRADES WILL PERMIT. EQUIPMENT LOCATIONS INDICATED ARE APPROXIMATE.
COORDINATE EXACT LOCATIONS AND REQUIRED CLEARANCES WITH EQUIPMENT SUPPLIER AND ALL TRADES PRIOR TO
INSTALLATION.
E.THE CONTRACTOR SHALL FURNISH AND INSTALL ALL THE EQUIPMENT INDICATED WITHIN THESE DRAWINGS UNLESS
OTHERWISE NOTED. VERIFY LOCATION AND DIMENSIONS IN THE FIELD PRIOR TO FABRICATION AND / OR INSTALLATION.
F.ALL ROOF PENETRATIONS SHALL BE AT THE CONTRACTOR'S EXPENSE. COORDINATE WITH OWNER'S ROOFING
CONTRACTOR SO AS NOT TO VOID ANY EXISTING ROOF WARRANTIES.
G.THE ENTIRE INSTALLATION SHALL BE GUARANTEED FREE OF DEFECTS AND CONTRACTOR SHALL REPAIR AND / OR
REPLACE ANY DEFECTIVE MATERIALS OR EQUIPMENT AT NO COST TO THE OWNER FOR A MINIMUM PERIOD OF ONE
YEAR FROM THE DATE OF ACCEPTANCE BY ARCHITECT OR ENGINEER.
H.ALL WORK SHALL BE SUBJECT TO THE ACCEPTANCE AND APPROVAL OF THE ARCHITECT AND OWNER. THE ARCHITECT
SHALL BE NOTIFIED OF ANY AND ALL DISCREPANCIES BETWEEN FIELD CONDITIONS AND THE CONTRACT DOCUMENTS
BEFORE PROCEEDING WITH THAT PORTION OF THE WORK. FAILURE OF PROPER NOTIFICATION DOES NOT RELIEVE
THE CONTRACTOR. THE CONTRACTOR SHALL CORRECT ANY AND ALL WORK ARISING FROM SUCH FAILURE TO
COORDINATE DISCREPANCIES TO THE SATISFACTION OF THE ARCHITECT WITHOUT ADDITIONAL COST TO THE OWNER.
I.COORDINATE ALL EQUIPMENT UTILITY INFORMATION SHOWN ON THIS SHEET WITH THE DUNKIN' BRANDS EQUIPMENT
SCHEDULE AND EQUIPMENT MANUFACTURER'S CUT SHEETS.
J.ALL EXTERIOR LIGHTS TO BE TIMECLOCK CONTROLLED.
K.ALL 15 AND 20 AMP, 120 VOLT RECEPTACLES IN KITCHEN AND PREP AREAS SHALL BE GFI TYPE.
L.ALL JUNCTION BOXES SHOWN ON THIS PLAN ARE TO BE INSTALLED ABOVE THE FINISHED CEILING.
M.ALL EMERGENCY AND EXIT FIXTURES SHALL BE CONNECTED TO LOCAL LIGHTING CIRCUIT AHEAD OF ANY SWITCHING.
PROVIDE ADDITIONAL FIXTURES AS NEEDED TO MEET THE CODE REQUIREMENTS PER LOCAL REQUIREMENTS.
N.PROVIDE WOOD BLOCKING BEHIND ALL EXTERIOR LIGHTING FIXTURES COORDINATE WITH GENERAL CONTRACTOR.
O.THE CONTRACTOR IS RESPONSIBLE FOR REVIEWING THE LATEST KITCHEN PLANS AND EQUIPMENT CUTS SHEETS FOR
PROPER EQUIPMENT LOCATIONS AND CONNECTION REQUIREMENTS PRIOR TO STARTING WORK.
EGREES LIGHT NOTES
1.ALL EGREES ILLUMINATION SHALL BE A MINIMUM AVERAGE OF 1 FOOT CANDLE.
2.EMERGENCY AND EXIT LIGHTS TO BE POWERED BY 90 MINUTES BATTERY BACKUP.
3.ALL EMERGENCY AND EXIT LIGHTS TO BE POWERED BY LIGHTING CIRCUIT SERVING SAME AREA.
4.EMERGENCY AND EXIT LIGHTS TO BE CONNECTED AHEAD OF SWITCHES.
5.ALL EGREES ILLUMINATION TO COMPLYWITH FBC 1006, 1008.
LIGHTING NOTES
1.LIGHTING TO COMPLY WITH FBC SECTION 505.5.3 FOR LIGHT DENSITY
2.50% OF LIGHTING FIXTURES TO BE HIGH EFFICIENCY LIGHTS.LIGHTING PLAN
NOT USED
E-2REMODELd a t e :
r e v i s i o n s :Boynton Beach FL 33483 2728 N Federal Hwy.1 3 . 0 6 . 2 0 2 5 PC # 3 1 0 2 8 7ventura-architecture.com
phone : (954) 423-1362
davie, florida 33325
11870 w state rd 84 #C14
A R 0 0 1 6 1 5 2
michael a. ventura
VENTURA
development inc
architectureA A 0 0 0 3 1 2 3
Fabian Morales
Drawn by:
project # :
2 5 0 3 2 1
AR0016152MICHAEL VEN
T
URASTAT E O F FLOR
I
D
AREGI
S
TERED A R C H ITECTDUNKIN' - BUILDING COMMENTS
07.23.2025 - fm1
1
LED LIGHT FIXTURE DESIGN NOTE:
ALTHOUGH FLUORESCENT LIGHT FIXTURES ARE
SHOWN AS THE STANDARD DESIGN OPTION, IT IS
HIGHLY RECOMMENDED THAT LED LIGHT FIXTURES
BE CONSIDERED. ALL FLUORESCENT FIXTURES
SHOWN HAVE LED ALTERNATES AVAILABLE
THROUGH VILLA LIGHTING, AND QUOTES CAN BE
OBTAINED FOR BOTH LIGHT PACKAGE TYPES.
LED-3 LED-4
LED-6
BACKROOM OPTION
ELECTRICIAN TO VERIFY EXISTING CONDITIONS OF ELECTRIC
PANELS TO REMAIN OR REDEVELOP ELECTRIC CIRCUITS.
SUBMIT TO ARCHITECT CHANGES TO UPDATE AS BUILT.
GC TO CONFIRM IF EXISTING CONDUITS ARE
IN GOOD CONDITIONS ADEQUATELY SI=E
FOR NEW DIGITAL BOARD REQUIREMENTS.
GC TO COORDINATE WITH SIGN VENDOR FOR
REQUIRED ELECTRIC ACCESS TO EXISTING
NEW LOCATIONS FOR SIGN INSTALLATION
PROVIDE AUTOMATIC
LIGHTING CONTROLS FOR
ENERGY CONSERVATION
KIOSKKIOSKSTORAGE
ElectricalPanelBACK OF HOUSE REMAIN AS IS
R2
R2
RRR
R2
R2
R2 R2 R2
R2 R2 R2 R2 R2
R2 R2 R2 R2 R2
R2
R2 R2 R2
RRRRRR
R2 R2
A
AA
A
WSCX-2WSCX-2WSCX-2GWT-2WT-2
LROD
RRRR
R
A-7 A-7 A-7
A-7 A-7 A-7 A-7 A-7
A-7 A-7
A-7
A-7 A-7 A-7 A-7 A-7 A-7
A-7A-7A-7
A-7
A-7
A-7
A-7
A-38 A-38 A-25CLGA-25CLGA-25CLG
A-9 A-9 A-9
A-9 A-9
A-9 A-9 A-9 A-9
A-9
A-9 A-9 A-9 A-9 A-9 A-9
B-8
B-8 B-8
B-8 B-8
B-8
A-25 A-23
A-23
A-23
A-23A-23A-23A-23
A-23
A-13 EXIST.
CIRCUIT
FOR SIGN
A-13 EXIST.
CIRCUIT
FOR SIGN
A-25 A-25
A-25 A-25
A-23
PENDANT LIGHT FIXTURE (LED)
C
INTERIOR FLUSH CEILING
SPEAKER
2x2 LAY-IN LED LIGHT
FIXTURE (NO OVERLAY)
TYP.
WSC-1 EXTERIOR UP / DOWN SCONCE
LIGHT
WSCX-2
V
EXTERIOR SPEAKER
ADJUSTABLE SPEAKER
VOLUME CONTROLS
SUSP. CLNG GRID SYSTEM
W/ ACOUSTICAL OR VINYL
CLAD CEILING TILES- SEE
PLAN FOR TYPES AND
LOCATIONS
RECESSED CAN DOWN LIGHT
FIXTURE (LED)
RECESSED CAN EXTERIOR
DOWN LIGHT FIXTURE (LED)
G
LED-1
LED-2
HANGING PENDANT LIGHT
SUPPLY AIR DIFFUSER-
4 WAY
P
EXTERIOR WALL MOUNT
STEM LIGHT
TRACK HEAD & LED LAMP
FLUE
EXTERIOR WALL PACK
LIGHTPENDANT LIGHT FIXTURE
EXIT SIGN
RETURN / CEILING
EXHAUST REGISTER
GYPSUM BOARD CEILING
P3
P4
WITHIN HANGING SOFFIT
2x4 LAY-IN LED LIGHT FIXTURE
(W/ ACRYLIC LENS) TYP.
BL
BATHROOM WALL SCONCE
EXIT/EMERGENCY LIGHT
WITH BATTERY BACKUP
EMERGENCY LIGHT WITH
BATTERY BACKUP
V VAPORPROOF LINEAR FIXTURE
LED-4
LED-6
NIGHT LIGHT 2x2 LAY-IN
LED LIGHT FIXTURE (NO
OVERLAY) TYP.LED-4
NIGHT 2x4 LAY-IN LED LIGHT
FIXTURE (W/ ACRYLIC LENS)
TYP.
LED-6
S
S
OCCUPANCY SENSOR