HomeMy WebLinkAboutEnlarged Lighting Plan - E1.1FEFE FE FE FE FEFE FE FE FE FE FEFE FE FE FE FE OS FE FEFE FE FE FE FE FE FE FE FE FE FE FE FEFE FE FE FE FE FE FE FEFEFE FE FE FE FE FE FE FE FE FE FE COORDINATE RESTROOM LIGHT FIXTURE LOCATIONS WITH CEILING STRUCTURE, DUCT WORK DIFFUSERS, SPRINKLERS AND GC. LIGHTING LAYOUT ADJUSTMENTS SHALL BE KEPT TO A MINIMUM. MAINTAIN LAYOUT AS CLOSELY AS POSSIBLE. PROVIDE STAINLESS STEEL COVER PLATES TYP IN RESTROOMS D 7 18 CUSTOMERWOMEN CUSTOMERMEN FAMILYTOILET MOTHER'SROOM ALCOVE 16.125 TYP OS OS OS OS NL NL NL NL NL ETR TYP68R ETR ETR MAINTAIN EXISTING DOWNLIGHT LOCATIONS FOR ALL RESTROOM L2D2 - 2916.1294' - 2"2' - 0"4' - 3"2' - 0" D 7 CUSTOMERWOMEN CUSTOMERMENFAMILYTOILET ALCOVE TYP 16.126 TYP 16.126 PROGRAM FOR MANUAL ON AT 100% LIGHT LEVEL AND 15 MINUTE TIME DELAY. WIRE PER MANUFACTURER'S RECOMMENDATIONS,INCLUDING DIMMING CONTROL TO ALL FIXTURES. D B 10R 16.080 TYP OF 6 10 10 1010 10 10 10 10 OS/D OS COMPANIONSENSOR 27 13 16.125 ETR TYP 16.125 18 OS/D H2P - 716.129 PART(1/2) BREAKROOM D B BREAKROOM16.080 TYP OF 6 16.133 TYP OF 6 /REF5E1.1 C 1 A D B 23 4 TYP16.126 TYP16.126 CARTSTORAGE VESTIBULE PICKUP STORAGE TYP 16.492 16.126 TYP16.126 CUSTOMERSERVICE VESTIBULE 16.126 RETURN STORAGE RETURNSTORAGE MOUNT AT STRUCTURE INCART STORAGE SUSPEND TO 10'-0", . IN VESTIBULE C 1 A D B 23 4 4' - 0"4' - 0"4' - 4"CARTSTORAGE VESTIBULE TYP68R TYP39 /REF 3 E1.2 /REF2E1.2 16.090 TYP OF 4 16.125 16.125 ETR 9' - 0"7' - 10"17' - 8"4' - 4" TYP39 ADD T-BAR AND CEILING TILE TO PATCH CEILING WHERE 2X4 LIGHT FIXTURES ARE REPLACED BY 2X2 LIGHT FIXTURES. NEW 2X2 LIGHT FIXTURES SHALL MAINTAIN CONSISTENT SPACING (E.G., ALL 2X2 INSTALLED IN PLAN NORTH END WHERE 2X4'S ARE BEING REPLACED). CUSTOMERSERVICE 18 RETURN STORAGE 16.125 PROGRAM TO MAXIMUM AVAILABLE TIME DELAY. PROGRAM FOR MANUAL ON OS TYP16.12516.131 PICKUP STORAGE H2P-5 3 VESTIBULE 5' - 9"5' - 11" ETR 39 16.125 16.125 H2P - 1 16.129 MOUNT ATSTRUCTURE,/REF2E1.2 1 9 16.0903 7' - 0"11' - 7"H2P-5 16.131 13 STORAGE TYP OF 3 TYP9 16.090 C D MEN WOMEN TYP 16.126 C DMEN OS WOMEN OS TYP68R MAINTAIN EXISTING DOWNLIGHT LOCATIONS FOR ALL RESTROOM ETR ETRTYP 16.125 COORDINATE RESTROOM LIGHT FIXTURE LOCATIONSWITH CEILING STRUCTURE, DUCT WORK DIFFUSERS, SPRINKLERS AND GC. LIGHTING LAYOUT ADJUSTMENTS SHALL BE KEPT TO A MINIMUM. MAINTAIN LAYOUT AS CLOSELY AS POSSIBLE. PROVIDE STAINLESS STEEL COVER PLATES TYP IN RESTROOMS H2P-1616.129 F 8 CANOPY TYP 16.126 SHEET: DRAWN BY: CHECKED BY: PROTO CYCLE: DOCUMENT DATE:CONSULTANTSSTIPULATION FOR REUSEPROTO:JOB NUMBER:THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT:CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.P (407) 661-9100F (407) 661-9101c-p.comFlorida Corporate Certificate #AA C0005262600 Maitland Center ParkwaySuite #200Maitland, FL 32751EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND MAY NOT REFLECT EXACT "AS-BUILT" CONDITIONS. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR SHALL CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINT THEMSELF WITH THIS KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY OF PERFORMING THE WORK PROPERLY. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS THAT OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH THIS KNOWLEDGE.12/8/2025 5:53:45 PME1.1 ENLARGEDLIGHTINGPLANS AJ/AS20240347BOYNTON BEACH, FL11/07/2511/07/25STORE NO: 05911 - 2769006/27/25BOYNTON BEACH, FLBV3625 S FEDERAL HWY11/07/25 KEYNOTES 16.080 REMOVE EXISTING FIXTURE INTERNALCOMPONENTS INCLUDING LOUVER, LAMPS, ANDBALLAST. INSTALL LED RETROFIT INTO EXISTINGFIXTURE HOUSING AND CONNECT TO EXISTINGCIRCUITRY AND CONTROLS. 16.090 REPLACE EXISTING LIGHT FIXTURES IN THISAREA WITH TYPE AND QUANTITY INDICATED.INSTALL NEW LIGHT FIXTURE IN SAME LOCATIONAS EXISTING LIGHT FIXTURE BEING REPLACED.RECONNECT TO EXISTING CIRCUITRY ANDCONTROLS. 16.125 EXISTING LIGHT FIXTURES TO REMAIN UNLESSNOTED OTHERWISE. 16.126 EXISTING LIGHT FIXTURE TO BE DEMOLISHED. 16.129 CONNECT TO EXISTING CIRCUIT PREVIOUSLYSERVING AREA LIGHTING THAT WAS REMOVED.MAINTAIN EXISTING CIRCUIT CONTROL UNLESSNOTED OTHERWISE. PROVIDE CONSTANT HOTFOR EMERGENCY EXIT AND LOCALLYCONTROLLED LIGHT FIXTURES. 16.131 CONNECT TO EXISTING CIRCUIT. 16.133 EXISTING LIGHT FIXTURES TO BE RELOCATED TONEW LOCATION AS SHOWN. 16.492 E.C. SHALL COORDINATE WITH GENERALCONTRACTOR AND ARCHITECTURALDEMOLITION PLANS THE EXTENT OF ELECTRICALDEMOLITION. REMOVE UNUSED DEVICES,BOXES, CONDUITS, AND WIRING BACK TOORIGINATING JUNCTION BOXES ORPANELBOARDS. REFERENCE POWER PLANS FORCIRCUITRY TO BE REUSED. DEMOLITION SHALLNOT AFFECT ACTIVE CIRCUITS. IF CIRCUIT ISDEMOLISHED ALL THE WAY TO PANELBOARD,REMOVE CIRCUIT BREAKER AND REPLACE WITHFILLER PLATE. UPDATE TYPEWRITTEN CIRCUITDIRECTORY IDENTIFYING CIRCUIT AS "SPACE".COORDINATE EXACT REQUIREMENTS WITHEXISTING CONDITIONS PRIOR TO BID. 1/4" = 1'-0"2 FRONT RESTROOM LIGHTING PLAN 1/8" = 1'-0"1 FRONT RESTROOM LIGHTING DEMO PLAN 1/4" = 1'-0"5 BREAKROOM LIGHTING PLAN 1/8" = 1'-0"3BREAKROOM LIGHTING DEMO PLAN 1/16" = 1'-0"8VESTIBULE/CUSTOMER SERVICE/PICKUP STORAGE LIGHTING DEMO PLAN 1/8" = 1'-0"9VESTIBULE/CUSTOMER SERVICE/PICKUP STORAGE LIGHTING PLAN 1/8" = 1'-0"6 LIQUOR RESTROOM LIGHTING DEMO PLAN 1/4" = 1'-0"7LIQUOR RESTROOM LIGHTING PLAN 1/8" = 1'-0"4CANOPY LIGHTING DEMO PLAN ISSUE BLOCKVOID