HomeMy WebLinkAboutLighting Plan - E1FE FE FEFE FE FE FE FE FE FE FE FE SSLSSLSSL FE FEFE FE FE FEFE FEFE FE FE FE BBB BBB BB FE FE FE FE FE FE FE AWS FE E1.15E1.1 3 E1.1 2 E1.11 EPH1 2EPH11 GE1 2 GE1 1 E1.19E1.1 8 ADJUST AIMING OF EMERGENCY LIGHT LAMP HEADS AS REQUIRED TO PROVIDE PROPER ILLUMINATION AT FLOOR, AVOIDING OBSTACLES AND SHADOWS AFTER STORE SET-UP IS COMPLETE, TYP C 1 A E F G I J D B H 2345 6 7 8 SALES TYP 16.125 TYP 16.12516.133 E1.1 6 E1.1 7 SE11 STORAGE 16.125 TYP OF 2 16.133 16.133 E1.1 4 3' - 10"7' - 3"11' - 0"11' - 0"11' - 0"11' - 0"CANOPY FURNISH AND INSTALL LITETRONICS #PASSMT1 SURFACEMOUNT KIT. TYP OF 5 CONTACT MICHAEL NASH FOR ORDERING INFORMATION. (479) 751-7123MICHAEL.NASH@REXELUSA.COMTYP8 H1P-8 16.129 CANOPY 16.090TYP OF 2 TYP50 SHEET: DRAWN BY: CHECKED BY: PROTO CYCLE: DOCUMENT DATE:CONSULTANTSSTIPULATION FOR REUSEPROTO:JOB NUMBER:THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT:CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.P (407) 661-9100F (407) 661-9101c-p.comFlorida Corporate Certificate #AA C0005262600 Maitland Center ParkwaySuite #200Maitland, FL 32751EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND MAY NOT REFLECT EXACT "AS-BUILT" CONDITIONS. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR SHALL CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINT THEMSELF WITH THIS KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY OF PERFORMING THE WORK PROPERLY. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS THAT OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH THIS KNOWLEDGE.12/8/2025 5:53:37 PME1 LIGHTINGPLAN AJ/AS20240347BOYNTON BEACH, FL11/07/2511/07/25STORE NO: 05911 - 2769006/27/25BOYNTON BEACH, FLBV3625 S FEDERAL HWY11/07/25 1.A. B. C. D.E. F. 2.A. B.a. b. c. C. D. 3. 4. 5. 6. 7. EXIT SIGN MOUNTINGWALL FIXTURE: CENTER 12" ABOVE DOOR OPENING.CEILING FIXTURE: ON CEILING OR AT HEIGHT SPECIFIED ON DRAWINGS.PENDANT FIXTURE: MATCH HEIGHT OF EXISTING PENDANT MOUNTED EXIT SIGNS. IF STORE DOES NOT HAVE PENDANT MOUNTED EXIT SIGNS, THEN PENDANT MOUNT SIGN 24" BELOW BOTTOM OF BAR JOIST. VERIFY MOUNTING HEIGHT WITH AHJ.COORDINATE LOCATIONS OF EXIT SIGNS TO ENSURE STORE SIGNAGE DOES NOT OBSTRUCT THEIR VIEW.THE USE OF TRITIUM BASED RADIOACTIVE EXIT SIGNAGE IS PROHIBITED. EMERGENCY LIGHT FIXTURE INSTALLATION EXIT SIGNS, EMERGENCY LIGHTS AND NIGHT LIGHTS SHALL NOT BE SWITCHED.MOUNTINGWALL FIXTURE: 12" BELOW FINISHED CEILING OR +10'-0" IN AREAS OF EXPOSED STRUCTURE, UNLESS NOTED OTHERWISE.PENDANT FIXTURE: BOTTOM CHORD OF BAR JOIST OR AT HEIGHT SPECIFIED ON DRAWINGS.REMOTE HEAD FIXTURE: HEADS CENTERED ABOVE DOOR OPENING +9'-0", UNLESS NOTED OTHERWISE AND BATTERY PACK MOUNTED ON INTERIOR SIDE OF WALL 12" BELOW FINISHED CEILING OR AT BAR JOIST IN AREAS OF EXPOSED STRUCTURE.REFER TO MANUFACTURER'S WRITTEN INSTRUCTIONS. ALLOW BATTERY TO CHARGE CONTINUOUSLY FOR A MINIMUM OF 24 HOURS BEFORE INITIAL TESTING.AFTER EMERGENCY LIGHT HAS BEEN POWERED DO NOT TURN OFF FOR EXTENDED PERIODS OF TIME. IN AREAS OF OPEN STRUCTURE, MOUNT STRIP FIXTURE TO BOTTOM CHORD OF BAR JOIST, UNLESS NOTED OTHERWISE. FIXTURES DENOTED WITH "ABJ" ARE TO BE FASTENED ON UNISTRUT CHANNELS MOUNTED TO THE BOTTOM SIDE OF THE TOP CHORD OF BAR JOISTS. LOCATE THE FIXTURES RUNNING PERPENDICULAR TO BAR JOISTS WITHIN BAR JOISTS WEBBING SPACES. DO NOT FASTEN FIXTURE OR UNISTRUT CHANNELS TO ROOF DECK. CONTRACTOR SHALL PROVIDE ALL UNISTRUT AND HARDWARE NECESSARY TO SPAN BAR JOIST AS REQUIRED FOR A COMPLETE INSTALLATION OF THE LIGHTING SYSTEM. PROVIDE SEPARATE BOXES FOR GANGED SWITCHES ON SEPARATE BRANCH CIRCUITS. CONTRACTOR IS RESPONSIBLE FOR THE COMPLETE INSTALLATION OF THE LIGHTING SYSTEM AS INDICATED ON PLANS AND/OR AS MODIFIED TO ACCOMMODATE EXISTING OBSTRUCTIONS. IDENTIFY CONFLICTS PRIOR TO ROUGH-IN. WHERE CONFLICTS WITH EXISTING UTILITIES OCCUR, ADJUST FIXTURE LOCATION AS REQUIRED. FIXTURES SHALL BE INSTALLED AS NEAR AS POSSIBLE TO LOCATIONS INDICATED ON PLANS. GENERAL LIGHTING NOTES 12.17.21 KEYNOTES 16.090 REPLACE EXISTING LIGHT FIXTURES IN THISAREA WITH TYPE AND QUANTITY INDICATED.INSTALL NEW LIGHT FIXTURE IN SAME LOCATIONAS EXISTING LIGHT FIXTURE BEING REPLACED.RECONNECT TO EXISTING CIRCUITRY ANDCONTROLS. 16.125 EXISTING LIGHT FIXTURES TO REMAIN UNLESSNOTED OTHERWISE. 16.129 CONNECT TO EXISTING CIRCUIT PREVIOUSLYSERVING AREA LIGHTING THAT WAS REMOVED.MAINTAIN EXISTING CIRCUIT CONTROL UNLESSNOTED OTHERWISE. PROVIDE CONSTANT HOTFOR EMERGENCY EXIT AND LOCALLYCONTROLLED LIGHT FIXTURES. 16.133 EXISTING LIGHT FIXTURES TO BE RELOCATED TONEW LOCATION AS SHOWN. 1" = 20'-0"1LIGHTING PLAN EXISTING LIGHTING FIXTURES NOT SHOWN ARE EXISTINGTO REMAIN AND ARE NOT AFFECTED BY THE SCOPE OFWORK ON THIS PROJECT. THIS INCLUDES ALL GENERALLIGHTING, EGRESS LIGHTING AND EXIT LIGHTING. 1. 2. 3. 4. 5. 6. 7. OCCUPANCY SENSORS IN RESTROOMS SHALL BE PROGRAMMED FOR AUTOMATIC ON AND MAXIMUM AVAILABLE TIME DELAY SETTINGS. OCCUPANCY SENSORS IN DELI, PRODUCE, AND BAKERY PREP AREAS SHALL BE PROGRAMMED WITH MAXIMUM AVAILABLE TIME DELAY SETTINGS. OCCUPANCY SENSORS IN WALK-IN COOLERS/FREEZERS SHALL BE LOW TEMPERATURE RATED AND CEILING MOUNTED WITH INCLUDED BRACKET. ADJUST AIMING FOR MAXIMUM COVERAGE, 10 MINUTE TIME DELAY. ALL OTHER OCCUPANCY SENSORS SHALL BE PROGRAMMED WITH THE MINIMUM AVAILABLE TIME DELAY SETTING UNLESS NOTED OTHERWISE. ALL SINGLE-POLE OCCUPANCY SENSORS SHALL BE PROGRAMMED FOR MANUAL ON LIGHTING CONTROL UNLESS NOTED OTHERWISE. ALL BI-LEVEL OCCUPANCY SENSORS SHALL BE PROGRAMMED FOR AUTOMATIC ON LIGHTING CONTROL FOR 50% OF FIXTURES AND WITH MANUAL ON MODE FOR REMAINING FIXTURES. WHERE TWO OCCUPANCY SENSORS ARE SHOWN IN THE SAME LOCATION WIRE FOR PARALLEL OPERATION. OCCUPANCY SENSOR NOTES12.17.21 ISSUE BLOCKVOID