HomeMy WebLinkAboutRefrigeration Electrical Panel Schedules and Details - RE1.3SUPPORT CONDUIT FROM TOP OR BOTTOM OF STRUCTURE ONLY. DO NOT INSTALL CONDUIT BELOW STRUCTURE. ROOF OPENING MAY CONTAIN MULTIPLE CONDUIT TYPES, SEE ELECTRICAL AND BASR PLANS. MINIMUM 2" GAP BETWEEN ADJACENT CONDUITS. OWNER PROVIDED MANUFACTURED CURB, SEE ARCHITECTURAL DETAILS FOR SIZE, INSULATION, ASSEMBLY, AND SEALING REQUIREMENTS SUPPORT CONDUIT PER SPECIFICATIONS, SEE ROOF SUPPORT DETAIL. REMOVABLE HOOD PROVIDED WITH CURB. DROP CONDUIT NEAR HOOD TO ALIGN WITH ROOF SUPPORT HEIGHT IF NEEDED. SECURE CONDUIT TO UNISTRUT AT TOP OF CURB 5" CENTER OF CONDUIT TO TOP OF CURB. PAINT CONDUIT TO MATCH ADJACENT CEILING COLOR TYPICAL REFRIGERATED CASE SYSTEM 12" WIRE PIGTAILS (TYP) 5' FLEX CONDUIT (TYP) ROUTE EMT CONDUITS (UNDER CASES, ABOVE SLAB) TO POINT OF TRANSITION TO FLEX PROVIDE TRANSITION FROM EMT TO FLEX BRANCH CIRCUIT AND EMS CONDUITS TO OTHER REFRIGERATED CASE SYSTEMS (TYP) BRACKET CONDUIT TO FLOOR AS REQUIRED BY CODE (TYP) ROUTE CONDUIT FOR BRANCH CIRCUITS FROM OVERHEAD THRU CHASE, ALONG WITH REFRIGERATION PIPING (TYP) PROVIDE (2) CONDUITS AND BRANCH CIRCUITS PER REFRIGERATED CASE SYSTEM. ONE CONDUIT WILL SERVE 120V CASE FANS, LIGHTS AND ANTI-SWEAT CIRCUITS; ONE CONDUIT WILL SERVE 208V CASE ELECTRIC DEFROST CIRCUIT. ON SYSTEMS WITHOUT ELECTRIC DEFROST, ONLY PROVIDE ONE CONDUIT PROVIDE 5' LENGTH OF FLEX CONDUIT WITH 12" PIGTAIL STUBBED FROM END OF EACH FLEX CONDUIT. PVC CHASE EMS CONDUIT: PROVIDE CONDUIT (WITH PULL WIRE) ROUTED 6" ABOVE BOTTOM OF BAR JOIST IN SALES FLOOR ACCESSIBLE CEILING SPACE THROUGH PVC CHASE. CONDUIT WILL BE SIZED 1" FOR (4) OR FEWER EMS CABLES AND 1-1/4" FOR (5) OR MORE EMS CABLES.REAR HALF OF REFRIGERATED CASE DESIGNATED FOR PIPING AND VALVES FRONT HALF OF REFRIGERATED CASE DESIGNATED FOR ELECTRICAL AND BAS COMPONENTS REFRIGERATED CASE CONTROLLER REFER TO BASR PLANS FOR CASE CONTROLLER TYPE, WIRING DETAILS, AND CONTROLLER TERMINATION POINTS, TYP CONDUITS FOR REFRIGERATED CASE POWER. ONE CONDUIT WILL SERVE 120V FANS, LIGHTS, AND ANTI-SWEAT HEATERS CIRCUITS. ONE CONDUIT WILL SERVE 208V ELECTRIC DEFROST CIRCUIT. REFER TO REFRIGERATION ELECTRICAL PLANS IF ELECTRIC DEFROST IS REQUIRED AND FOR FEEDER AND CONDUIT SIZES. CONDUIT FOR DAISY CHAINED BASR CABLING. FROM PREVIOUS BASR CONTROLLER OR MASTER CONTROLLER. REFER TO BASR PLANS AND ONE-LINE DIAGRAM. TO NEXT BASR CONTROLLER IN DAISY CHAIN OR MASTER CONTROLLER. REFER TO BASR PLANS AND ONE-LINE DIAGRAM. CASE JUNCTION BOX FOR TRANSITION FROM EMT TO FLEX CONDUIT, TYP. FLEX CONDUITS FROM CASE JUNCTION BOX TO CASE CONTROLLER, TYP. ONE CONDUIT FOR 120V CASE FANS, LIGHTS, AND ANTI-SWEAT HEATERS CIRCUIT. ONE CONDUIT FOR 208V ELECTRIC DEFROST CIRCUIT. REFRIGERATED CASE, TYP. REFER TO PLANS FOR QUANTITY OF CASES ON CASE LINEUP. ROUTE CONDUITS WITH REFRIGERATION PIPING TO ACCESSIBLE JOIST SPACE. REFER TO REFRIGERATION PLANS FOR CHASE ROUTING DETAILS, IF REQUIRED. EMT CONDUIT BETWEEN CASE JUNCTION BOXES, TYP PROVIDE CEILING MOUNTED MANUAL SWITCH 'HUBBELL' CLASS HBLDS3 OR ‘EATON’CLASS AHDS30. IF OVER 30 AMPS PROVIDE ‘HUBBEL’CLASS HBLDS6 OR ‘EATON’AHDS60. WITH NEMA 4X WATERTIGHT NON-METALLIC ENCLOSURE FOR CONNECTION OF EVAPORATOR COIL FANS (CF) AND/OR ELECTRIC DEFROST (ED), (WHERE SHOWN ON DRAWINGS). PROVIDE PLACARD ON CEILING DETAILING PURPOSE OF EACH MANUAL SWITCH AND THE ELECTRICAL SOURCE (PANEL AND CIRCUIT NUMBER). NOTE: DO NOT LOCATE WP JUNCTION BOX DIRECTLY IN FRONT OF DISCHARGE FAN, OFFSET TO SIDE. TYPICAL COIL EMT CONDUIT AND WIRING TO NEXT COIL POWER JUNCTION BOX ON SAME SYSTEM WHEN MULTIPLE COILS ARE IN SAME COOLER/FREEZER BOX. POWER CONDUIT AND WIRING SAME SIZE AND QUANTITY AS WIRING TO PANEL. 1" EMT CONDUIT PENETRATION SEALED WITH SILICONE SEALANT. NOTE: TAP DEFROST CIRCUIT IN JUNCTION BOX WITH #10 AWG FOR CONNECTION TO UNIT. MAXIMUM LENGTH OF TAP CONDUCTOR 18" CONDULET AT CEILING PENETRATION FILLED WITH SILICONE COIL FAN/DEFROST POWER EMT CONDUIT AND WIRING TO DESIGNATED PANEL VIA WALK-IN FAN/DEFROST CONTROL DEVICE. FINAL CONNECTION BY RC. COOLER/FREEZER BOX CEILING CEILING MOUNTED WP JUNCTION BOX WITH THREADED HUBS AND GASKETED COVERPLATE. SEAL TOP OF JUNCTION BOX TO COOLER/FREEZER CEILING WITH SILICONE SEALANT. 1" LIQUID-TIGHT FLEXIBLE METAL CONDUIT TO KNOCKOUT ON UNIT. FINAL CONNECTION TO COIL BY RC. Ø Ø Ø PROVIDE 208/3Ø HOME RUN TO DESIGNATED PANEL BOARD . FINAL CONNECTION AT CASE BY R.C. CALCULATION OF 3Ø UNBALANCED LOAD B LOAD = (12.6 A + 12.6 A) x .866 = 21.8 A (HIGH LEG) A LOAD = (12.6 A + 9.9 A) x .866 = 19.5 A B LOAD = (12.6 A + 12.6 A) x .866 = 21.8 A (HIGH LEG) C LOAD = (12.6 A + 9.9 A) x .866 = 19.5 A NOTES: ON SYSTEMS WITH UNEQUAL LOADS, REC (REFRIGERATION ELECTRICAL CONTRACTOR) SHALL ARRANGE CONNECTIONS FOR MAXIMUM BALANCE A CCBBA C B A 12.6 A 9.9 A12.6 A 4 DOOR CASE5 DOOR CASE5 DOOR CASE TYPICAL REFRIGERATED CASE SYSTEM NTS1ROOF PENETRATION (CONDUIT) NTS2CASE CONNECTION WIRING (PVC CHASE) NTS3CASE CONDUIT ROUTING NTS4EVAPORATOR COIL WIRING NTS5CASE DEFROST WIRING SHEET: DRAWN BY: CHECKED BY: PROTO CYCLE: DOCUMENT DATE:CONSULTANTSSTIPULATION FOR REUSEPROTO:JOB NUMBER:THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT:CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.P (407) 661-9100F (407) 661-9101c-p.comFlorida Corporate Certificate #AA C0005262600 Maitland Center ParkwaySuite #200Maitland, FL 32751CUSHING TERRELL306 W. RAIL ROAD SUITE 104MISSOULA, MT 59802Phone: (406)728-9522Fax: (406)728-8287EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND MAY NOT REFLECT EXACT "AS-BUILT" CONDITIONS. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR SHALL CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINT THEMSELF WITH THIS KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY OF PERFORMING THE WORK PROPERLY. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS THAT OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH THIS KNOWLEDGE. DOCUMENTS WITHOUT SIGNATURE AND REQUIRED SEAL OF AOR/EOR ARE NOT FOR CONSTRUCTION RE1.3 REFRIGERATION ELECTRICAL PANEL SCHEDULES AND DETAILS DM20240347BOYNTON BEACH, FL11/07/2511/07/25STORE NO: 5911-2769006/27/25BOYNTON BEACH, FLSP3625 S FEDERAL HWY.A. LEGEND: (N) NEW, (E ) EXISTING, (M) MODIFY, B. CONTROLLED VIA 100A-3P CONTACTOR CIRCUIT NOTES: MISCELLANEOUS 0.4 PER NEC 210.20(A) 0.5 WATER HEAT 0.0 100% 0.0 ELECTRIC HEAT 0.0 100% 0.0 DEMAND AMPS 33.9 KITCHEN EQUIPMENT 0.0 PER NEC 220.56 0.0 DEMAND LOAD (kVA):12.2 MOTORS 4.4 PER NEC 430.24 4.7 CONVENIENCE OUTLETS 1.6 PER NEC 220.44 1.6 CONNECTED AMPS:29.9 LIGHTING 4.4 PER NEC 210.20(A) 5.5 CONNECTED LOAD(kVA):10.8 LOAD CLASSIFICATION CONNECTED LOAD(kVA) FACTOR DEMAND LOAD PANEL TOTALS 30.8 31.7 27.2 TOTAL CONNECTED PHASE AMPS 3700 3800 3260 TOTAL CONNECTED PHASE VA SPARE E 1 20 41 42 20 1 E SPACE AS12 CASE LIGHTS (11) E 1 20 39 280 40 20 1 E SPACE AS12 CASE FANS E 1 20 37 150 38 20 1 E SPACE BS20 GLY CASE LIGHTS (11) M 1 20 35 60 36 20 1 E SPACE BS20 GLY CASE FANS M 1 20 33 40 34 20 1 E SPACE AS08 CASE FANS E 1 20 31 1100 32 20 1 E SPACE AS07 CASE LIGHTS (11) E 1 20 29 1260 30 20 1 E SPARE AS07 CASE FANS E 1 20 27 420 28 20 1 E SPARE BS18 GLY CASE LIGHTS (11) M 1 20 25 50 26 20 1 E SPARE BS18 GLY CASE FANS M 1 20 23 110 24 20 1 E SPARE SPARE M 1 20 21 180 22 20 1 E AS11 EMS CONTROLLER BS17 GLY CASE LIGHTS (11) M 1 20 19 90 180 20 20 1 E AS10 EMS CONTROLLER BS17 GLY CASE FANS M 1 20 17 150 180 18 20 1 E AS08 CASE RECEPTACLE AS04 CASE LIGHTS (11) E 1 20 15 590 180 16 20 1 E AS08 CASE RECEPTACLE AS04 CASE FANS E 1 20 13 770 180 14 20 1 M BS17 GLY CASE RECEPTACLE AS03 CASE LIGHTS (11) E 1 20 11 590 180 12 20 1 E AS04 CASE RECEPTACLE AS03 CASE FANS E 1 20 9 770 180 10 20 1 E AS04 CASE RECEPTACLE AS02 CASE LIGHTS (11) E 1 20 7 460 180 8 20 1 E AS03 CASE RECEPTACLE AS02 CASE FANS E 1 20 5 550 180 6 20 1 E AS03 CASE RECEPTACLE AS01 CASE LIGHTS (11) E 1 20 3 980 180 4 20 1 E AS02 CASE RECEPTACLE AS01 CASE FANS E 1 20 1 360 180 2 20 1 E AS02 CASE RECEPTACLE NOTES POLE AMP NO NO AMP POLE NOTESLOAD NAME CKT BRK CKT PHASE A LOAD (VA) PHASE B LOAD (VA) PHASE C LOAD (VA) CKT BRK CKT LOAD NAME MODEL TYPE:EXISTING WIRES:4 MANUFACTURER:EXISTING PHASE:3 NOTES:YES TYPE OF MAIN:100A MLO VOLTAGE:208Y/120 MOUNTING TYPE:EXISTING LOCATION:HYBRID HOUSE DTA AMPS:100 MINIMUM AIC RATING:10,000 EXISTING PANEL: (E)CHA2 A. LEGEND: (N) NEW, (E ) EXISTING, (M) MODIFY, B. CONTROLLED VIA 100A-3P CONTACTOR CIRCUIT NOTES: MISCELLANEOUS 0.2 PER NEC 210.20(A) 0.2 WATER HEAT 0.0 100% 0.0 ELECTRIC HEAT 10.4 100% 10.4 DEMAND AMPS 47.6 KITCHEN EQUIPMENT 0.0 PER NEC 220.56 0.0 DEMAND LOAD (kVA):17.1 MOTORS 2.0 PER NEC 430.24 2.1 CONVENIENCE OUTLETS 0.7 PER NEC 220.44 0.7 CONNECTED AMPS:45.2 LIGHTING 3.0 PER NEC 210.20(A) 3.7 CONNECTED LOAD(kVA):16.3 LOAD CLASSIFICATION CONNECTED LOAD(kVA) FACTOR DEMAND LOAD PANEL TOTALS 44.2 41.6 49.8 TOTAL CONNECTED PHASE AMPS 5300 4990 5970 TOTAL CONNECTED PHASE VA SPARE E 1 20 41 42 20 1 E SPACE B06 CASE LIGHTS (11) E 1 20 39 460 40 20 1 E SPACE B06 CASE A/S HTRS E 1 20 37 1670 38 20 1 E SPACE B06 CASE FANS E 1 20 35 300 36 20 1 E SPACE B05 CASE LIGHTS (11) E 1 20 33 550 34 20 1 E SPACE B05 CASE A/S HTRS E 1 20 31 930 32 20 1 E SPACE B05 CASE A/S HTRS E 1 20 29 1040 30 20 1 E SPACE B05 CASE FANS E 1 20 27 350 28 20 1 E SPACE B04 CASE LIGHTS (11) E 1 20 25 430 26 20 1 E SPACE B04 CASE A/S HTRS (6) E 1 20 23 1560 24 20 1 E SPACE B04 CASE FANS E 1 20 21 280 22 20 1 E SPACE B03 CASE LIGHTS (11) E 1 20 19 430 20 20 1 E SPACE B03 CASE A/S HTRS E 1 20 17 1560 18 20 1 E SPACE B03 CASE FANS E 1 20 15 280 16 20 1 E SPACE B02 CASE LIGHTS (11) E 1 20 13 460 120 14 20 1 M BS19 GLY CASE FANS B02 CASE FANS E 1 20 11 300 100 12 20 1 M BS19 GLY CASE LIGHTS B02 CASE A/S HTRS E 1 20 9 1670 180 10 20 1 E B07 EMS CONTROLLER B01 CASE LIGHTS (11) E 1 20 7 550 180 8 20 1 E B06 CASE RECEPTACLE B01 CASE A/S HTRS E 1 20 5 930 180 6 20 1 E B04 CASE RECEPTACLE B01 CASE A/S HTRS E 1 20 3 1040 180 4 20 1 E B03 CASE RECEPTACLE B01 CASE FANS E 1 20 1 350 180 2 20 1 E B02 CASE RECEPTACLE NOTES POLE AMP NO NO AMP POLE NOTESLOAD NAME CKT BRK CKT PHASE A LOAD (VA) PHASE B LOAD (VA) PHASE C LOAD (VA) CKT BRK CKT LOAD NAME MODEL TYPE:EXISTING WIRES:4 MANUFACTURER:EXISTING PHASE:3 NOTES:YES TYPE OF MAIN:100A MLO VOLTAGE:208Y/120 MOUNTING TYPE:EXISTING LOCATION:HYBRID HOUSE DTB AMPS:100 MINIMUM AIC RATING:10,000 EXISTING PANEL: (E)CHB1 A. LEGEND: (N) NEW, (E ) EXISTING, (M) MODIFY CIRCUIT NOTES: MISCELLANEOUS 1.1 PER NEC 210.20(A) 1.4 WATER HEAT 0.0 100% 0.0 ELECTRIC HEAT 1.1 100% 1.1 DEMAND AMPS 29.4 KITCHEN EQUIPMENT 0.0 PER NEC 220.56 0.0 DEMAND LOAD (kVA):10.6 MOTORS 5.0 PER NEC 430.24 5.2 CONVENIENCE OUTLETS 0.0 PER NEC 220.44 0.0 CONNECTED AMPS:26.3 LIGHTING 2.3 PER NEC 210.20(A) 2.9 CONNECTED LOAD(kVA):9.5 LOAD CLASSIFICATION CONNECTED LOAD(kVA) FACTOR DEMAND LOAD PANEL TOTALS 24.4 29.2 25.1 TOTAL CONNECTED PHASE AMPS 2930 3505 3015 TOTAL CONNECTED PHASE VA SPARE E 1 20 41 42 20 1 E SPACE SPARE E 1 20 39 40 20 1 E SPACE SPARE E 1 20 37 38 20 1 E SPACE SPARE E 1 20 35 36 20 1 E SPACE CU5 CASE FANS & LTS N 1 20 33 1110 34 20 1 E SPACE BS09 GLY COIL FANS M 1 20 31 220 32 20 1 E SPACE BS08 GLY COIL FANS M 1 20 29 305 30 20 1 E SPACE BS07 GLY CASE LIGHTS (11) M 1 20 27 140 28 20 1 E SPACE BS07 GLY CASE FANS M 1 20 25 145 26 20 1 E SPACE BS06 GLY CASE LIGHTS (11) M 1 20 23 190 24 20 1 E SPACE BS06 GLY CASE FANS M 1 20 21 325 22 20 1 E SPACE BS05 GLY CASE LIGHTS (11) M 1 20 19 250 20 20 1 E SPACE BS05 GLY CASE FANS M 1 20 17 410 18 20 1 E SPACE BS04 GLY CASE LIGHTS (11) M 1 20 15 195 245 16 20 1 M BS14 GLY CASE LIGHTS (11) BS04 GLY CASE FANS M 1 20 13 135 205 14 20 1 M BS14 GLY CASE FANS BS03 GLY CASE LIGHTS (11) M 1 20 11 245 650 12 20 1 E BS13 COIL FANS BS03 GLY CASE FANS M 1 20 9 210 430 10 20 1 E BS12 COIL FANS BS02 GLY CASE LIGHTS (11) M 1 20 7 165 540 8 20 1 E BS11 COIL FANS BS02 GLY CASE FANS M 1 20 5 135 1080 6 20 1 E BS10 COIL FANS BS01 GLY CASE LIGHTS (11) M 1 20 3 220 630 4 20 1 E DAIRY COOLER DOOR LTS (11) BS01 GLY CASE FANS M 1 20 1 170 1100 2 20 1 E DAIRY COOLER DOOR HTRS NOTES POLE AMP NO NO AMP POLE NOTESLOAD NAME CKT BRK CKT PHASE A LOAD (VA) PHASE B LOAD (VA) PHASE C LOAD (VA) CKT BRK CKT LOAD NAME MODEL TYPE:EXISTING WIRES:4 MANUFACTURER:EXISTING PHASE:3 NOTES:YES TYPE OF MAIN:100A MLO VOLTAGE:208Y/120 MOUNTING TYPE:EXISTING LOCATION:HYBRID HOUSE DTB AMPS:100 MINIMUM AIC RATING:10,000 EXISTING PANEL: (E)CHB2 ISSUE BLOCKVOID