HomeMy WebLinkAboutElectrical Plans, E1, E1.1, E2FEFEFEFEFEFEFEFEFEFEFEFESSLSSLSSLFEFEFEFEFEFEFEFEFEFEFEFEBBBB B BBBFEFEFEFEFEFEFEAWSFEE1.15E1.13E1.12E1.11EPH12EPH11GE12GE11E1.19E1.18ADJUST AIMING OF EMERGENCY LIGHT LAMP HEADS AS REQUIRED TO PROVIDE PROPER ILLUMINATION AT FLOOR, AVOIDING OBSTACLES AND SHADOWS AFTER STORE SET-UP IS COMPLETE, TYPC1AEFGIJDBH2345678SALESTYP16.125TYP16.12516.133E1.16E1.17SE11STORAGE16.125TYP OF 216.13316.133E1.143' - 10"7' - 3"11' - 0"11' - 0"11' - 0"11' - 0"BREEZEWAYFURNISH AND INSTALL LITETRONICS #PASSMT1 SURFACEMOUNT KIT. TYP OF 5CONTACT MICHAEL NASH FOR ORDERING INFORMATION. (479) 751-7123MICHAEL.NASH@REXELUSA.COMTYP8H1P-816.129CANOPY16.090TYP OF 2TYP50SHEET:DRAWN BY:CHECKED BY:PROTO CYCLE:DOCUMENT DATE:CONSULTANTSSTIPULATION FOR REUSEPROTO:JOB NUMBER:THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT:CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.P (407) 661-9100F (407) 661-9101c-p.comFlorida Corporate Certificate #AA C0005262600 Maitland Center ParkwaySuite #200Maitland, FL 32751EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND MAY NOT REFLECT EXACT "AS-BUILT" CONDITIONS. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR SHALL CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS.EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINT THEMSELF WITH THIS KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY OF PERFORMING THE WORK PROPERLY. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS THAT OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH THIS KNOWLEDGE.6/25/2026 2:45:31 PME1LIGHTINGPLANAJ/AS20240347BOYNTON BEACH, FL11/07/2511/07/25STORE NO: 05911 - 2769006/27/25BOYNTON BEACH, FLBV3625 S FEDERAL HWY06/16/261. EXIT SIGN MOUNTINGA. WALL FIXTURE: CENTER 12" ABOVE DOOR OPENING.B. CEILING FIXTURE: ON CEILING OR AT HEIGHT SPECIFIED ON DRAWINGS.C. PENDANT FIXTURE: MATCH HEIGHT OF EXISTING PENDANT MOUNTED EXIT SIGNS. IF STORE DOES NOT HAVE PENDANT MOUNTED EXIT SIGNS, THEN PENDANT MOUNT SIGN 24" BELOW BOTTOM OF BAR JOIST. D. VERIFY MOUNTING HEIGHT WITH AHJ.E. COORDINATE LOCATIONS OF EXIT SIGNS TO ENSURE STORE SIGNAGE DOES NOT OBSTRUCT THEIR VIEW.F. THE USE OF TRITIUM BASED RADIOACTIVE EXIT SIGNAGE IS PROHIBITED.2. EMERGENCY LIGHT FIXTURE INSTALLATION A. EXIT SIGNS, EMERGENCY LIGHTS AND NIGHT LIGHTS SHALL NOT BE SWITCHED.B. MOUNTINGa. WALL FIXTURE: 12" BELOW FINISHED CEILING OR +10'-0" IN AREAS OF EXPOSED STRUCTURE, UNLESS NOTED OTHERWISE.b. PENDANT FIXTURE: BOTTOM CHORD OF BAR JOIST OR AT HEIGHT SPECIFIED ON DRAWINGS.c. REMOTE HEAD FIXTURE: HEADS CENTERED ABOVE DOOR OPENING +9'-0", UNLESS NOTED OTHERWISE AND BATTERY PACK MOUNTED ON INTERIOR SIDE OF WALL 12" BELOW FINISHED CEILING OR AT BAR JOIST IN AREAS OF EXPOSED STRUCTURE.C. REFER TO MANUFACTURER'S WRITTEN INSTRUCTIONS. ALLOW BATTERY TO CHARGE CONTINUOUSLY FOR A MINIMUM OF 24 HOURS BEFORE INITIAL TESTING.D. AFTER EMERGENCY LIGHT HAS BEEN POWERED DO NOT TURN OFF FOR EXTENDED PERIODS OF TIME.3. IN AREAS OF OPEN STRUCTURE, MOUNT STRIP FIXTURE TO BOTTOM CHORD OF BAR JOIST, UNLESS NOTED OTHERWISE.4. FIXTURES DENOTED WITH "ABJ" ARE TO BE FASTENED ON UNISTRUT CHANNELS MOUNTED TO THE BOTTOM SIDE OF THE TOP CHORD OF BAR JOISTS. LOCATE THE FIXTURES RUNNING PERPENDICULAR TO BAR JOISTS WITHIN BAR JOISTS WEBBING SPACES. DO NOT FASTEN FIXTURE OR UNISTRUT CHANNELS TO ROOF DECK.5. CONTRACTOR SHALL PROVIDE ALL UNISTRUT AND HARDWARE NECESSARY TO SPAN BAR JOIST AS REQUIRED FOR A COMPLETE INSTALLATION OF THE LIGHTING SYSTEM.6. PROVIDE SEPARATE BOXES FOR GANGED SWITCHES ON SEPARATE BRANCH CIRCUITS.7. CONTRACTOR IS RESPONSIBLE FOR THE COMPLETE INSTALLATION OF THE LIGHTING SYSTEM AS INDICATED ON PLANS AND/OR AS MODIFIED TO ACCOMMODATE EXISTING OBSTRUCTIONS. IDENTIFY CONFLICTS PRIOR TO ROUGH-IN. WHERE CONFLICTS WITH EXISTING UTILITIES OCCUR, ADJUST FIXTURE LOCATION AS REQUIRED. FIXTURES SHALL BE INSTALLED AS NEAR AS POSSIBLE TO LOCATIONS INDICATED ON PLANS.GENERAL LIGHTING NOTES12.17.21KEYNOTES16.090 REPLACE EXISTING LIGHT FIXTURES IN THISAREA WITH TYPE AND QUANTITY INDICATED.INSTALL NEW LIGHT FIXTURE IN SAME LOCATIONAS EXISTING LIGHT FIXTURE BEING REPLACED.RECONNECT TO EXISTING CIRCUITRY ANDCONTROLS.16.125 EXISTING LIGHT FIXTURES TO REMAIN UNLESSNOTED OTHERWISE.16.129 CONNECT TO EXISTING CIRCUIT PREVIOUSLYSERVING AREA LIGHTING THAT WAS REMOVED.MAINTAIN EXISTING CIRCUIT CONTROL UNLESSNOTED OTHERWISE. PROVIDE CONSTANT HOTFOR EMERGENCY EXIT AND LOCALLYCONTROLLED LIGHT FIXTURES.16.133 EXISTING LIGHT FIXTURES TO BE RELOCATED TONEW LOCATION AS SHOWN.1" = 20'-0"1LIGHTING PLANEXISTING LIGHTING FIXTURES NOT SHOWN ARE EXISTINGTO REMAIN AND ARE NOT AFFECTED BY THE SCOPE OFWORK ON THIS PROJECT. THIS INCLUDES ALL GENERALLIGHTING, EGRESS LIGHTING AND EXIT LIGHTING.1. OCCUPANCY SENSORS IN RESTROOMS SHALL BE PROGRAMMED FOR AUTOMATIC ON AND MAXIMUM AVAILABLE TIME DELAY SETTINGS.2. OCCUPANCY SENSORS IN DELI, PRODUCE, AND BAKERY PREP AREAS SHALL BE PROGRAMMED WITH MAXIMUM AVAILABLE TIME DELAY SETTINGS.3. OCCUPANCY SENSORS IN WALK-IN COOLERS/FREEZERS SHALL BE LOW TEMPERATURE RATED AND CEILING MOUNTED WITH INCLUDED BRACKET. ADJUST AIMING FOR MAXIMUM COVERAGE, 10 MINUTE TIME DELAY.4. ALL OTHER OCCUPANCY SENSORS SHALL BE PROGRAMMED WITH THE MINIMUM AVAILABLE TIME DELAY SETTING UNLESS NOTED OTHERWISE.5. ALL SINGLE-POLE OCCUPANCY SENSORS SHALL BE PROGRAMMED FOR MANUAL ON LIGHTING CONTROL UNLESS NOTED OTHERWISE.6. ALL BI-LEVEL OCCUPANCY SENSORS SHALL BE PROGRAMMED FOR AUTOMATIC ON LIGHTING CONTROL FOR 50% OF FIXTURES AND WITH MANUAL ON MODE FOR REMAINING FIXTURES.7. WHERE TWO OCCUPANCY SENSORS ARE SHOWN IN THE SAME LOCATION WIRE FOR PARALLEL OPERATION.OCCUPANCY SENSOR NOTES12.17.211ISSUE BLOCK1 PR#3 06/16/26PR#106/25/26 FEFEOSFEFEFEFEFEFEFEFEFEFEFECOORDINATE RESTROOM LIGHT FIXTURE LOCATIONS WITH CEILING STRUCTURE, DUCT WORK DIFFUSERS, SPRINKLERS AND GC. LIGHTING LAYOUT ADJUSTMENTS SHALL BE KEPT TO A MINIMUM. MAINTAIN LAYOUT AS CLOSELY AS POSSIBLE.PROVIDE STAINLESS STEEL COVER PLATES TYP IN RESTROOMSD718CUSTOMERWOMENCUSTOMERMENFAMILYTOILETMOTHER'SROOMALCOVE16.125TYPOSOSOSOSNLNLNLNLNLETRTYP68RETRETRMAINTAIN EXISTING DOWNLIGHT LOCATIONS FOR ALL RESTROOML2D2 - 2916.1294' - 2"2' - 0"4' - 3"2' - 0"D7CUSTOMERWOMENCUSTOMERMENFAMILYTOILETALCOVETYP16.126TYP16.126PROGRAM FOR MANUAL ON AT 100% LIGHT LEVEL AND 15 MINUTE TIME DELAY. WIRE PER MANUFACTURER'S RECOMMENDATIONS,INCLUDING DIMMING CONTROL TO ALL FIXTURES.DB10R16.080TYP OF 61010101010101010OS/DOS COMPANIONSENSOR271316.125ETRTYP16.12518OS/DH2P - 716.129PART(1/2)BREAKROOMDBBREAKROOM16.080TYP OF 616.133TYP OF 6/REF5E1.1C1ADB234TYP16.126TYP16.126CARTSTORAGEVESTIBULEPICKUP STORAGETYP16.49216.126TYP16.126CUSTOMERSERVICEVESTIBULE16.126RETURN STORAGERETURNSTORAGEMOUNT AT STRUCTURE INCART STORAGESUSPEND TO 10'-0", . IN VESTIBULEC1ADB2344' - 0"4' - 0"4' - 4"CARTSTORAGEVESTIBULETYP68RTYP39/REF3E1.2/REF2E1.216.090TYP OF 416.12516.125ETR9' - 0"7' - 10"17' - 8"4' - 4"TYP39ADD T-BAR AND CEILING TILE TO PATCH CEILING WHERE 2X4 LIGHT FIXTURES ARE REPLACED BY 2X2 LIGHT FIXTURES. NEW 2X2 LIGHT FIXTURES SHALL MAINTAIN CONSISTENT SPACING (E.G., ALL 2X2 INSTALLED IN PLAN NORTH END WHERE 2X4'S ARE BEING REPLACED).CUSTOMERSERVICE18RETURN STORAGE16.125PROGRAM TO MAXIMUM AVAILABLE TIME DELAY. PROGRAM FOR MANUAL ONOSTYP16.12516.131PICKUP STORAGEH2P-53VESTIBULE5' - 9"5' - 11"ETR3916.12516.125H2P - 116.129MOUNT ATSTRUCTURE,/REF2E1.21916.09037' - 0"11' - 7"H2P-516.13113STORAGETYP OF 3TYP916.090CDMENWOMENTYP16.126CDMENOSWOMENOSTYP68RMAINTAIN EXISTING DOWNLIGHT LOCATIONS FOR ALL RESTROOMETRETRTYP16.125COORDINATE RESTROOM LIGHT FIXTURE LOCATIONSWITH CEILING STRUCTURE, DUCT WORK DIFFUSERS, SPRINKLERS AND GC. LIGHTING LAYOUT ADJUSTMENTS SHALL BE KEPT TO A MINIMUM. MAINTAIN LAYOUT AS CLOSELY AS POSSIBLE.PROVIDE STAINLESS STEEL COVER PLATES TYP IN RESTROOMSH2P-1616.129F8BREEZEWAYTYP16.126SHEET:DRAWN BY:CHECKED BY:PROTO CYCLE:DOCUMENT DATE:CONSULTANTSSTIPULATION FOR REUSEPROTO:JOB NUMBER:THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT:CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.P (407) 661-9100F (407) 661-9101c-p.comFlorida Corporate Certificate #AA C0005262600 Maitland Center ParkwaySuite #200Maitland, FL 32751EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND MAY NOT REFLECT EXACT "AS-BUILT" CONDITIONS. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR SHALL CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS.EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINT THEMSELF WITH THIS KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY OF PERFORMING THE WORK PROPERLY. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS THAT OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH THIS KNOWLEDGE.6/25/2026 2:45:35 PME1.1ENLARGEDLIGHTINGPLANSAJ/AS20240347BOYNTON BEACH, FL11/07/2511/07/25STORE NO: 05911 - 2769006/27/25BOYNTON BEACH, FLBV3625 S FEDERAL HWY06/16/26KEYNOTES16.080 REMOVE EXISTING FIXTURE INTERNALCOMPONENTS INCLUDING LOUVER, LAMPS, ANDBALLAST. INSTALL LED RETROFIT INTO EXISTINGFIXTURE HOUSING AND CONNECT TO EXISTINGCIRCUITRY AND CONTROLS.16.090 REPLACE EXISTING LIGHT FIXTURES IN THISAREA WITH TYPE AND QUANTITY INDICATED.INSTALL NEW LIGHT FIXTURE IN SAME LOCATIONAS EXISTING LIGHT FIXTURE BEING REPLACED.RECONNECT TO EXISTING CIRCUITRY ANDCONTROLS.16.125 EXISTING LIGHT FIXTURES TO REMAIN UNLESSNOTED OTHERWISE.16.126 EXISTING LIGHT FIXTURE TO BE DEMOLISHED.16.129 CONNECT TO EXISTING CIRCUIT PREVIOUSLYSERVING AREA LIGHTING THAT WAS REMOVED.MAINTAIN EXISTING CIRCUIT CONTROL UNLESSNOTED OTHERWISE. PROVIDE CONSTANT HOTFOR EMERGENCY EXIT AND LOCALLYCONTROLLED LIGHT FIXTURES.16.131 CONNECT TO EXISTING CIRCUIT.16.133 EXISTING LIGHT FIXTURES TO BE RELOCATED TONEW LOCATION AS SHOWN.16.492 E.C. SHALL COORDINATE WITH GENERALCONTRACTOR AND ARCHITECTURALDEMOLITION PLANS THE EXTENT OF ELECTRICALDEMOLITION. REMOVE UNUSED DEVICES,BOXES, CONDUITS, AND WIRING BACK TOORIGINATING JUNCTION BOXES ORPANELBOARDS. REFERENCE POWER PLANS FORCIRCUITRY TO BE REUSED. DEMOLITION SHALLNOT AFFECT ACTIVE CIRCUITS. IF CIRCUIT ISDEMOLISHED ALL THE WAY TO PANELBOARD,REMOVE CIRCUIT BREAKER AND REPLACE WITHFILLER PLATE. UPDATE TYPEWRITTEN CIRCUITDIRECTORY IDENTIFYING CIRCUIT AS "SPACE".COORDINATE EXACT REQUIREMENTS WITHEXISTING CONDITIONS PRIOR TO BID.1/4" = 1'-0"2FRONT RESTROOM LIGHTING PLAN1/8" = 1'-0"1FRONT RESTROOM LIGHTING DEMO PLAN1/4" = 1'-0"5BREAKROOM LIGHTING PLAN1/8" = 1'-0"3BREAKROOM LIGHTING DEMO PLAN1/16" = 1'-0"8VESTIBULE/CUSTOMER SERVICE/PICKUP STORAGE LIGHTING DEMO PLAN1/8" = 1'-0"9VESTIBULE/CUSTOMER SERVICE/PICKUP STORAGE LIGHTING PLAN1/8" = 1'-0"6LIQUOR RESTROOM LIGHTING DEMO PLAN1/4" = 1'-0"7LIQUOR RESTROOM LIGHTING PLAN1/8" = 1'-0"4BREEZEWAY LIGHTING DEMO PLAN11ISSUE BLOCK1 PR#3 06/16/26PR#106/25/26 FE FE FEFE FE FE FE FE FE FE FE FE SSLSSLSSL FE FEFE FE FE FEFE FEFE FE FE FE BBB BBB BB FE FE FE FE FE FE FE AWS FE J J J E2.2 4 E2.2 3 EPH14 EPH1 3 GE21 GE2 2 E2.2 2 CONTRACTOR TO FURNISH AND INSTALL NEW STARLINE BUSWAY CIRCUIT BREAKER PLUG-IN UNITS AS REQUIRED: CONTACT MEGREPS,JON MATTHEWS OR RANDY MATTHEWS(501) 821-6200 EX: 301WALMART@MEGREPS.COM E2.2 1 CONTROL BOX PROVIDED BY SIGN INSTALLER WITH FACTORY INSTALLED DISCONNECT SWITCH. VERIFY LOCATION WITH SIGN INSTALLER PRIOR TO INSTALLATION,TYP OF 2. REUSE EXISTING SIGNAGE CIRCUIT L2D1-10.EXTEND CIRCUITRY AS REQUIRED TO NEW CONNECTIONS. REUSE ALL CONTROLS ASSOCIATED WITH THE CIRCUIT. C 1 A E F G I J D B H 2345 6 7 8 E2.27 EXISTING BUSWAY BL2D. EXISTING BUSWAY BL2C. EXISTING BUSWAY BL2A. EXISTING BUSWAY BL2B. EXISTING MAIN SWITCHBOARD MSB AND PANELBOARDS H1A, H1P, L1D (2-SEC), L1U AND C1 IN EDC1. EXISTING PANELBOARD LLQ IN LIQUOR STOCKROOM. EXISTING PANELBOARDS H2A, H2B, H2P, L2D1 (2-SEC), L2B AND L2U IN EDC2. SALES EXISTING PANELBOARD L2D2 IN ALCOVE. C1-19 16.482EAS E2.26 EXISTNG PANELBOARDL2D3 (2-SEC) IN DELI PREP. PROVIDE LEGRAND PLUGMOLD MODEL#AL20GB618TR (ALUMINUM) WITH MATCHINGPOWER FEED AND END FITTING. MOUNT AT +3'-5" ,TYP OF 3. L2D1-26CART STORAGE REUSE EXISTINGCIRCUIT FORRELOCATING KIOSK. REUSE EXISTING CIRCUIT FORRELOCATING ATM. +9'-0" 16.650 3/4"C ENVIRONMENTALCAGE E2.2 5 PROVIDE UNISTRUT MOUNTED 4'-0" ABOVE FLOOR ACROSS BACK OF RACK SECTION FOR MOUNTING OF ELECTRICAL AND DATA DEVICES. 16.489 WATERDISPENSER /REF1E2.1 LIQUORSALES 16.507 TYP OF 3DISPLAYS BL2C-21 TYP 16.201 16.492 CARD READER,MONITOR,CAMERAAND AIR CURTAIN 16.492 CARD READERAND CAMERA L2D2-19 L2D2-17 16.145 16.145 RELOCATED LOTTERY PLAYAND LOTTERY VENDING MACHINE L2D1 - 2 NEW KIOSK WP TYP 16.201 CONTROL BOX PROVIDED BY SIGN INSTALLER WITH FACTORY INSTALLED DISCONNECT SWITCH. VERIFY LOCATION WITH SIGN INSTALLER PRIOR TO INSTALLATION. TYP OF 2. L2D2 - 34 WALMART SPARK WALMART SPARK L2D1-12 NEW KIOSK L2D3-39 NEW LOTTERYVENDING MACHINE 16.489 KEY BOX SHEET: DRAWN BY: CHECKED BY: PROTO CYCLE: DOCUMENT DATE:CONSULTANTSSTIPULATION FOR REUSEPROTO:JOB NUMBER:THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT:CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.P (407) 661-9100F (407) 661-9101c-p.comFlorida Corporate Certificate #AA C0005262600 Maitland Center ParkwaySuite #200Maitland, FL 32751EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND MAY NOT REFLECT EXACT "AS-BUILT" CONDITIONS. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR SHALL CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINT THEMSELF WITH THIS KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY OF PERFORMING THE WORK PROPERLY. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS THAT OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH THIS KNOWLEDGE.12/8/2025 5:53:56 PME2 POWER PLAN AJ/AS20240347BOYNTON BEACH, FL11/07/2511/07/25STORE NO: 05911 - 2769006/27/25BOYNTON BEACH, FLBV3625 S FEDERAL HWY11/07/25 1" = 20'-0"1POWER PLAN REPLACE ALL DAMAGED AND NON-WHITE RECEPTACLES (EXCEPT ORANGE RECEPTACLES) WITH WHITE RECEPTACLES AND ALL NON-STAINLESS STEEL COVERPLATES WITH STAINLESS STEEL, INCLUDING BLANKS. KEYNOTES 16.145 CONNECT CIRCUIT(S) TO EXISTING BRANCHCIRCUITRY. MINIMUM WIRE SIZE ANDPANELBOARD CIRCUIT ARE NOTED. VERIFY SIZE,RATING AND CONDITION OF EXISTING BRANCHCIRCUIT CONDUIT AND WIRE PRIOR TO USE TOENSURE THAT THEY MEET REQUIRED SIZE, ANDALL U.L. RATINGS AND REPLACE AS REQUIRED. 16.201 EXTERIOR SIGN POWER: WHERE ELECTRICALCONNECTIONS FOR SIGNAGE OCCUR BELOWROOF LINE, ROUTE POWER TO WALL AT SIGNCONTROL BOX(ES). WHERE ELECTRICALCONNECTIONS FOR SIGNAGE OCCUR ABOVEROOF LINE, PROVIDE UNISTRUT TO MOUNTCONTROL BOX(ES) TO BACK SIDE OF PARAPET.LOW VOLTAGE WIRING FROM CONTROL BOX(ES)TO SIGN PROVIDED AND INSTALLED BY OTHERS.REFER TO ARCHITECTURAL DRAWINGS FOREXACT SIGN LOCATION(S) PRIOR TOINSTALLATION. PROVIDE ONLY ONEPENETRATION THROUGH THE ROOF. REFARCHITECTURAL EXTERIOR WALL SECTIONSAND SIGN ATTACHMENT FOR ROOF ANDPARAPET PENETRATION REQUIREMENTS. 16.482 ELECTRONIC ARTICLE SURVEILLANCE SYSTEM:E.C. SHALL DISCONNECT, EXTEND, ANDRECONNECT ALL ELECTRICAL CIRCUITRY FORNEW OR RELOCATED EQUIPMENT. VERIFYCONDITION OF BRANCH CIRCUIT, CONDUIT, ANDWIRE PRIOR TO USE TO ENSURE THAT THEYMEET ALL U.L. RATINGS. CONDUITS SHOULD BEAT LEAST ¾”. IF IN POOR CONDITION ORUNDERSIZED REPLACE AS REQUIRED PERSENSORMATIC INSTRUCTIONS. COORDINATECONDUIT REPLACEMENT WITH WAL-MARTCONSTRUCTION MANAGER. 16.489 RELOCATE, EXTEND, AND RECONNECTCIRCUITRY AND ELECTRICAL DEVICES FORRELOCATED AND/OR NEW EQUIPMENT. VERIFYCONDITION OF BRANCH CIRCUITRY, CONDUITAND WIRE TO ENSURE THEY MEET ALL U.L.RATINGS AND REPLACE AS REQUIRED. VERIFYFINAL LOCATION OF RELOCATED/NEWEQUIPMENT WITH WALMART CONSTRUCTIONMANAGER PRIOR TO ROUGH-IN. 16.492 E.C. SHALL COORDINATE WITH GENERALCONTRACTOR AND ARCHITECTURALDEMOLITION PLANS THE EXTENT OF ELECTRICALDEMOLITION. REMOVE UNUSED DEVICES,BOXES, CONDUITS, AND WIRING BACK TOORIGINATING JUNCTION BOXES ORPANELBOARDS. REFERENCE POWER PLANS FORCIRCUITRY TO BE REUSED. DEMOLITION SHALLNOT AFFECT ACTIVE CIRCUITS. IF CIRCUIT ISDEMOLISHED ALL THE WAY TO PANELBOARD,REMOVE CIRCUIT BREAKER AND REPLACE WITHFILLER PLATE. UPDATE TYPEWRITTEN CIRCUITDIRECTORY IDENTIFYING CIRCUIT AS "SPACE".COORDINATE EXACT REQUIREMENTS WITHEXISTING CONDITIONS PRIOR TO BID. 16.507 DIGITAL DISPLAYS: MOUNT JUNCTION BOX ATSTRUCTURE. AFTER INSTALLATION OF DROPPOLE AND DISPLAY MOUNTING BRACKET,EXTEND CONDUCTORS IN ½” FLEXIBLE METALCONDUIT, ROUTED INSIDE DROP POLE, TO EACHDISPLAY MOUNTING BRACKET. PROVIDE 120V,20A DUPLEX RECEPTACLE ON REAR OF EACHDISPLAY MOUNTING BRACKET AND MAKE FINALTERMINATIONS. COORDINATE DISPLAYLOCATIONS WITH STORE SETUP SUPERVISOR. 16.650 CONDUIT SLEEVE: PROVIDE 1-1/2" CONDUITSLEEVE WITH BUSHINGS ABOVE BAR JOIST(UNLESS NOTED OTHERWISE). GENERAL POWER NOTES 01.26.24 1. 2. 3. 4. A. B. C. 5. A. B.C. 6. 7. TELEPOWER POLE(S): MOUNT JUNCTION BOX(ES) TO TOP SIDE OF BOTTOM CHORD OF BAR JOIST. INSTALL FURNISHED POWER POLE AND TERMINATE WIRING TO JUNCTION BOX. PROVIDE UNISTRUT SUPPORTS AND HARDWARE TO SECURE TELEPOWER POLE PLUMB TO BUILDING STRUCTURE. REF POWER POLE CONNECTION DETAIL. PROVIDE LIQUID-TIGHT FLEXIBLE METAL CONDUIT AND WIRING FROM DISCONNECT SWITCH OR JUNCTION BOX TO EQUIPMENT KNOCKOUT OR ELECTRICAL CONNECTION POINT. WHERE EQUIPMENT NAMEPLATE PROTECTIVE DEVICE RATING DIFFERS FROM SIZE PROVIDED, NOTIFY WALMART CONSTRUCTION MANAGER IMMEDIATELY TO COORDINATE RESOLUTION. ELECTRONIC FIRE PROTECTION/SECURITY ALARM BOXES AND CONDUITS SHOWN ON POWER PLANS SHALL BE PROVIDED UNDER THIS CONTRACT. IN ADDITION, UNLESS NOTED OTHERWISE, THE FOLLOWING GENERAL NOTES APPLY:ALL ALARM JUNCTION BOXES SHALL BE 4"X4"X2-1/8" MINIMUM.ALARM RACEWAYS SHALL BE 3/4" MINIMUM WITH PULL WIRE AND INSULATING BUSHINGS AT END OF VERTICAL RACEWAY RUN.VERTICAL RACEWAYS FROM ALARM BOXES SHALL BE EITHER CONCEALED INSIDE WALL OR SURFACE MOUNTED (TO MATCH JUNCTION BOX MOUNTING). ALL VERTICAL RUNS SHALL BE TURNED 90-DEGREES AT TOP SIDE OF BOTTOM CHORD OF BAR JOIST AND EXTENDED HORIZONTALLY TO A LOCATION ACCESSIBLE BY VERTICAL FLOOR TYPE LIFT. UPON COMPLETION OF ELECTRICAL INSTALLATION AND PRIOR TO ENERGIZING CIRCUIT:INSPECT WIRE AND CABLE FOR PHYSICAL DAMAGE.PERFORM CONTINUITY TEST.VERIFY PROPER PHASING CONNECTION TO ALL THREE PHASE MOTOR LOADS.CONDUIT AND WIRING TO RTU'S AND AHU'S SHALL BE THROUGH EQUIPMENT CURB. NO ROOF PENETRATIONS OR CONDUITS ROUTED ACROSS ROOF ARE PERMITTED. REFERENCE PROTECTIVE DEVICE SETTINGS REPORT FOR PROTECTIVE DEVICE MANUFACTURER, TYPE, AND SETTING REQUIREMENTS. ISSUE BLOCK