HomeMy WebLinkAboutNew Opening Plans and Details - S1, S2MATCH EXISTING FF EL REF ARCH TOC EL A BB EXISTING CONT WALL FTG EXISTING 8" CMU WALL 1/2" DIA x 10" SMOOTH DOWELS AT 24" OC (3 MIN) CENTERED ON JOINT WITH GREASE ONE END; LOCATE DOWEL 4" FROM FACE OF CMU EA END (1) #4 CONT #4 x 2'-0" DOWELS AT 16" OC; DRILL AND EMBED 4" INTO EXISTING GROUTED CMU WITH ADHESIVE ANCHOR (REF SPECS)10"1'-2" REF ARCH 8"SLOPE 8" CMU BEYOND REMOVE AND REPLACE CONCRETE PAVING AS REQD 1/2" DIA x 10" SMOOTH ROUND DOWELS AT 24" OC CENTERED ON JOINT; DOWELS MUST BE LEVEL AND SQUARE WITH JOINT 6"1/2" DIA x 10" SMOOTH DOWELS AT 24" OC (3 MIN); GREASE END IN NEW SLAB AND CENTER ON JOINT; DRILL AND EMBED 5" INTO EXISTING SLAB WITH ADHESIVE ANCHOR (REF SPECS) EXISTING CONC SLAB EXISTING CONCRETE PAVING 1/2" DIA x 10" SMOOTH DOWELS AT 24" OC (3 MIN); GREASE END IN NEW SLAB AND CENTER ON JOINT; DRILL AND EMBED 5" INTO EXISTING SLAB WITH ADHESIVE ANCHOR (REF SPECS) NOTE: DOWELS MUST BE LEVEL AND SQUARE WITH JOINT. NEW OPENING NEW CONCRETE SLAB (3'-4" MAX) REF PLAN (2) #6 CONT PROVIDE (1) #6 BAR EF FOR LENGTH REQUIRED, TYP GROUT ALL REINFORCED CELLS AND CONTINUE REINF TO BOTTOM OF EXISTING BOND BEAM PER ELEVATION, TYP2 3/4"2 3/4" 8" SECTION A -12" CMU WALL SECTION B -12" CMU WALL OH NOTES: 1. RE-POINT ALL AFFECTED MORTAR JOINTS. 2. ALL WORK SHOWN IN THIS DETAIL SHALL BE DONE ON INSIDE FACE OF WALL, UNLESS APPROVED BY ARCHITECT OF RECORD. 3. SHORE EXISTING STRUCTURE AS REQUIRED PRIOR TO STARTING ANY NEW WORK. 4. EXISTING BOND BEAM REINF SHALL NOT BE CUT OR DAMAGED. 5. EXTEND GROUTED LINTEL REINF 2'-0" OR 40 db (WHICHEVER IS GREATER) BEYOND FACE OF OPENING EA SIDE. INSTALL #6 DOWEL x 2'-0" IN EACH VERTICAL CELL; EMBED 4" INTO EXISTING CMU BOND BEAM WITH ADHESIVE ANCHOR (REF SPECS) IF EXISTING VERTICAL WALL REINF IN GROUTED CELL IS PRESENT, CHIP OUT GROUT AS REQUIRED TO PLACE LINTEL REINFORCING. DO NOT DAMAGE EXISTING REINFORCING REPLACE JAMB BLOCKS AND GROUT SOLID WITH FINE OR COARSE GROUT; SURFACE TREATMENT OF NEW BLOCK TO MATCH ORIGINAL (SPLIT FACE OR SMOOTH FACE) INSTALL NEW REINFORCEMENT; REF JAMB DETAIL FOR SIZE AND REINFORCING; SPLICE BARS 39" AND USE BARS WITH 6'-0" TO 8'-0" LENGTHS; IF EXISTING VERTICAL WALL REINFORCEMENT IN GROUTED CELL IS PRESENT, THIS IS NOT REQUIRED SAWCUT AND REMOVE CMU WALL AS REQUIRED TO PROVIDE OPENING AND LINTEL; CONTRACTOR SHALL PROVIDE SHORING PRIOR TO WALL DEMOLITION INSTALL #6 DOWEL x 2'-0" IN EACH VERTICAL CELL; EMBED 4" INTO EXISTING CMU WITH ADHESIVE ANCHOR (REF SPECS) CLEAN OUT ALL CELLS TO RECEIVE NEW REINF; REMOVE ALL DEBRIS, INSULATION, LOOSE MORTAR AND MORTAR WHICH OBSTRUCTS THE FLOW OF GROUT PRIOR TO INSTALLATION OF REINFORCEMENT SAWCUT AND REMOVE EXISTING FACE SHELLS AS NECESSARY TO INSTALL NEW REINF AND TO CLEAN OUT ALL VERTICAL CELLS INSTALL NEW LINTEL BLOCK AND REINFORCEMENT; REF LINTEL DETAIL FOR SIZE AND REINFORCING RESTORE THE FACE OF THE CMU BY INSTALLING SOAP BLOCKS AND NEW BLOCKS AS NECESSARY; SURFACE TREATMENT OF NEW BLOCK TO MATCH ORIGINAL (SPLIT FACE OR SMOOTH FACE) SAWCUT AND REMOVE FACE SHELLS IN THE COURSE ABOVE THE LINTEL AS NECESSARY TO GROUT THE NEW LINTEL GROUT SOLID ALL CELLS CONTAINING REINFORCING WITH FINE OR COARSE GROUT USING THE LOW LIFT METHOD (5'-0" MAX. GROUT LIFTS); GROUT TO BE CONSOLIDATED USING VIBRATORS BO BOND BEAM EL 112'-8" (FIELD VERIFY)(NOM) 8 " (NOM) 1'-0"3 1/2"TYP REF NOTE #5 EXISTING 12" CMU WALL EXISTING 12" CMU WALL REF ARCH TO OPNG EL MATCH EXISTING FF EL 7 B D EXISTING CONT WALL FTG EXISTING CMU WALL 2 S1 REMOVE SLAB AS REQD TO ALLOW FOR REMOVAL OF CMU TO 8" BELOW FINISHED FLOOR INTERIOR EXTERIOR NOTES: 1. SHORE EXISTING STRUCTURE AS REQUIRED PRIOR TO STARTING ANY NEW WORK. 2. IF A CMU CONTROL JOINT IS LOCATED WITHIN THE NEW OPENING OR 2'-8" EITHER SIDE OF NEW OPENING. NOTIFY ENGINEER OF RECORD PRIOR TO CUTTING OF WALL. 3 S1 3' - 4"EXISTING CMU CONTROL JOINT, TYP EXISTING OPENING 6.7 10' - 0"BUILDING KEY PLAN 1 2 7 8 A C K B D 5 F ABOVE ABOVE S1 1 S2 2 S2 3 ABOVE S1 4 STATEMENT OF SPECIAL INSPECTIONS SPECIAL INSPECTIONS ARE REQUIRED. REFER TO APPENDIX B OF THE PROJECT SPECIFICATIONS FOR THE FOLLOWING INFORMATION REGARDING THE REQUIREMENTS OF SPECIAL INSPECTIONS: 1. THE MATERIALS, SYSTEMS, COMPONENTS AND WORK REQUIRED TO HAVE SPECIAL INSPECTIONS. 2. THE TYPE AND EXTENT OF EACH SPECIAL INSPECTION. 3. THE TYPE AND EXTENT OF EACH TEST. 4. ADDITIONAL SPECIAL INSPECTION REQUIREMENTS FOR WIND OR SEISMIC RESISTANCE (WHEN APPLICABLE). 5. THE FREQUENCY OF SPECIAL INSPECTIONS AND TESTING. 1 E.32' - 0"2' - 0"ON 1-S2REF NOTE #1EXISTING CMU JOINT 1 S2 A. BUILDING CODE 2023 FBC B. WIND LOADS 1. ULTIMATE WIND SPEED 169 MPH 2. NOMINAL WIND SPEED 131 MPH 3. RISK CATEGORY II 4. EXPOSURE CATEGORY C 5. ENCLOSURE CLASSIFICATION ENCLOSED C. DOOR DESIGN WIND PRESSURE (SERVICE) 1. MAN DOOR ±46.6 PSF DOOR DESIGN LOADS P (407) 661-9100F (407) 661-9101c-p.comFlorida Corporate Certificate #AA C0005262600 Maitland Center ParkwaySuite #200Maitland, FL 32751ENGINEER OF RECORD: BENJAMIN BRYAN BAILEY, P.E. 930 CENTRAL ST. KANSAS CITY, MO 64105 FL LICENSE #88408JOHNSTONBAURKHOLDERSSOCIATESc o n s u l t i n g s t r u c t u r a l e n g i n e e r s930 C 816.421.4200 ·· K C MO ENTRAL ANSASITY,64105 WWW.JBAENGR.COMSHEET: DRAWN BY: CHECKED BY: PROTO CYCLE: DOCUMENT DATE:CONSULTANTSSTIPULATION FOR REUSEPROTO:JOB NUMBER:THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT:CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.JBA NO. 25350059114/21/2026 9:13:33 AMS1 NEW OPENING PLANS AND DETAILS POI20240347BOYNTON BEACH, FL11/07/2511/07/25STORE NO: 05911 - 2769006/27/25BOYNTON BEACH, FLJSH3625 S FEDERAL HWY3/4" = 1'-0"2 SLAB AT OPENING WITH STOOP 4.0-3 3/4" = 1'-0"3 CMU LINTEL AT OPENING IN EXISTING WALL 4.1-1 1/8" = 1'-0"1 NEW OPENING PLAN GENERAL NOTES GENERAL 1. FURNISH ALL LABOR, MATERIALS AND EQUIPMENT NECESSARY TO COMPLETE THE WORK SHOWN OR IMPLIED BY THESE DRAWINGS. SHOP DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT AND ENGINEER FOR REVIEW AND APPROVAL PRIOR TO COMMENCING WORK. 2. EXISTING CONDITIONS SHOWN MAY NOT REFLECT EXACT “AS-BUILT” CONDITIONS. BIDDERS SHALL FIELD VERIFY EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BID. WITHIN ONE WEEK FROM THE START OF CONSTRUCTION DATE GENERAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING MATERIAL, MEASUREMENTS, AND ELEVATIONS AND SHALL NOTIFY THE ARCHITECT, STRUCTURAL ENGINEER OF RECORD AND THE OWNER’S CONSTRUCTION MANAGER OF ANY DISCREPANCIES OR FORESEEN PROBLEMS. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL FIELD MEASUREMENTS, EXISTING CONDITIONS, AND KNOWN COMPLICATIONS WITH THE MATERIAL SUPPLIERS. 3. GENERAL CONTRACTOR SHALL CAREFULLY COORDINATE DEMOLITION AND NEW CONSTRUCTION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. 4. GENERAL CONTRACTOR SHALL PROTECT EXISTING STRUCTURES, UTILITIES, PROPERTY, ETC DURING CONSTRUCTION. RESTORE ALL ITEMS DAMAGED, AS REQUIRED BY OWNER'S REPRESENTATIVE, TO THE OWNER'S SATISFACTION AT NO COST TO OWNER OR WITHOUT EXTENSION OF CONTRACT TIME. 5. BUILDING COMPONENTS ABANDONED BY THE SCOPE OF WORK SHALL BE SECURED TO PREVENT FALLING, LOOSENING OR CREATING DAMAGE OF ANY KIND IN THE FUTURE. 6. GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING TEMPORARY SUPPORT AND MAINTAINING STABLITY OF EXISTING STRUCTURE DURING ALL PHASES OF CONSTRUCTION. 7. BEFORE OR CONCURRENT WITH ANY EXCAVATIONS ADJACENT TO THE EXISTING BUILDING FOUNDATION OR SLAB, GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING TEMPORARY SUPPORT FOR THE BASE AND SUBGRADE OF THE EXISTING SLAB AND FOUNDATIONS TO PREVENT UNDERMINING. 8. GENERAL CONTRACTOR SHALL PROVIDE FIRE PROTECTION FOR THE EXISTING STRUCTURE AND BUILDING CONTENTS DURING WELDING OR ANY OTHER CONSTRUCTION ACTIVITY THAT GENERATES SPARKS OR INTENSE HEAT. 9. THE STRUCTURAL ENGINEER OF RECORD, ITS EMPLOYEES, AND REPRESENTATIVES SHALL NOT BE RESPONSIBLE FOR, AND WILL NOT HAVE CONTROL OF, CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE CONSTRUCTION WORK; NOR WILL THEY BE RESPONSIBLE FOR ANY FAILURE BY THE CONTRACTOR TO PERFORM OR COMPLETE CONSTRUCTION IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. CONCRETE AND REINFORCING STEEL 1. MINIMUM COMPRESSIVE STRENGTH (f'c) AT THE END OF 28 DAYS SHALL BE AS FOLLOWS: A. INTERIOR CAST-IN-PLACE CONCRETE SLABS 4000 PSI SPECIFICATION SECTION 03314 B. EXTERIOR CAST-IN-PLACE CONCRETE SLABS REF SPECS SPECIFICATION SECTION 03310 FOR ALL OTHER CONCRETE PROPERTIES REFER TO SPECIFICATIONS. 2. CONCRETE FREEZING AND THAWING EXPOSURE CLASS SHALL BE F0 AND SULFATE EXPOSURE CLASS SHALL BE S0. 3. REINFORCING STEEL SHALL MEET ASTM SPECIFICATION A 615, DEFORMED BAR, GRADE 60 OR ASTM SPECIFICATION A 706, DEFORMED BAR, GRADE 60. 4. REFER TO ACI 315 FOR DETAILING PRACTICES AND FABRICATION, AND ACI 301 FOR STANDARD PRACTICE FOR MIXING AND PLACING CONCRETE AND CONCRETE COVER. STRUCTURAL STEEL 1. STRUCTURAL STEEL SHALL MEET THE FOLLOWING MINIMUM YIELD STRENGTH AND SPECIFICATIONS. FABRICATION AND ERECTION SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE "AISC CODE OF STANDARD PRACTICE". STRUCTURAL STEEL YIELD ASTM SPECIFICATION A. ANGLES, ANCHOR BOLTS, CHANNELS & PLATES 36 KSI A 36, UNO B. WIDE FLANGE STEEL SHAPES: 50 KSI A 992 2. ALL STRUCTURAL STEEL SHALL HAVE ONE SHOP COAT OF RUST INHIBITOR PRIMER PAINT CONFORMING TO THE SPECIFICATIONS. FIELD TOUCH UP ALL UNPAINTED, NICKED AND WELDED AREAS. PAINT ALL STEEL EXPOSED TO VIEW TO MATCH EXISTING. 3. WELDING SHALL MEET ANSI/AWS D1.1 STRUCTURAL WELDING CODE. ELECTRODES SHALL BE 70 KSI LOW HYDROGEN. STEEL JOISTS AND JOIST GIRDERS 1. EXISTING STEEL JOISTS AND JOIST GIRDERS ARE ASSUMED TO BE IN GOOD CONDITION AND IN COMPLIANCE WITH THE STEEL JOIST INSTITUTE SPECIFICATIONS. ANY DAMAGE TO EXISTING JOISTS OR GIRDERS SHALL BE REPORTED PRIOR TO ADDING LOAD TO FRAMING. 2. ALL WELDING SHALL CONFORM TO THE CURRENT AMERICAN WELDING SOCIETY SPECIFICATIONS AND BE PERFORMED BY CERTIFIED WELDERS. DO NOT OVER WELD OR BURN THRU JOIST MATERIAL. ANY DAMAGE TO EXISTING JOIST SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY. MASONRY 1. CONCRETE MASONRY UNITS SHALL MEET ASTM SPECIFICATION C 90. THE SPECIFIED DESIGN COMPRESSIVE STRENGTH OF CONCRETE MASONRY (f'm) SHALL BE 2000 PSI. THE NET AREA COMPRESSIVE STRENGTH OF THE CONCRETE MASONRY UNITS SHALL BE 2000 PSI. 2. MORTAR SHALL BE A PREBLENDED DRY MIX CONFORMING TO ASTM C 1714 AND MEETING THE PROPERY SPECIFICATIONS OF ASTM C 270 TYPE "S" MORTAR. REF SPECIFICATION 04200 FOR ADDITIONAL REQUIREMENTS. 3. GROUT SHALL MEET ASTM SPECIFICATION C 476 AND HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 2000 PSI. REF SPECIFICATION SECTION 04200 FOR ADDITIONAL REQUIREMENTS. 4. GROUT SHALL BE MECHANICALLY CONSOLIDATED USING A VIBRATOR WITH A MAXIMUM 3/4" DIAMETER HEAD. REF SPECIFICATION SECTION 04200. 5. CONCRETE MASONRY SHALL BE LIGHT WEIGHT OR NORMAL WEIGHT AND SHALL BE GROUTED ONLY AT REINFORCED CELLS AND BOND BEAMS, UNO. POST-INSTALLED ANCHORS 1. POST-INSTALLED ANCHORS SHALL ONLY BE USED WHERE SPECIFIED ON THE DRAWINGS. REFER TO SPECIFICATION 05090 FOR ADDITIONAL INFORMATION. SUBGRADE AND BASE 1. PRIOR TO PLACEMENT OF SLABS IN SLAB REMOVAL AREAS, EXPOSED SUBGRADE SHALL BE COMPACTED TO AT LEAST 95% OF THE STANDARD PROCTOR MAXIMUM DRY DENSITY (ASTM D698). WHERE SOILS ARE DISTURBED TO A DEPTH GREATER THAN 1'-0", COMPACTION SHALL BE PERFORMED IN A MAXIMUM 8 INCH LOOSE LIFTS. 2. IN SLAB REMOVAL AREAS WHERE SUBGRADE IS NEEDED TO RAISE PAD TO PROPER ELEVATION, PROVIDE BASE AND/OR CHOKER MATERIAL AS INDICATED IN SPECS. DESIGN LOADS 1. BUILDING CODE A. BUILDING CODE 2023 FLORIDA BUILDING CODE (2023 FBC) 2. GRAVITY LOADS A. ROOF DEAD LOAD 15 PSF (PER EXISTING DRAWINGS) B. ROOF LIVE LOADS 1. ROOF 20 PSF (MIN OR SNOW LOAD) C. SNOW LOADS 1. GROUND SNOW LOAD (Pg) N/A 3. LATERAL LOADS A. WIND LOADS 1. BASIC WIND SPEED (3-SECOND GUST) - ULTIMATE WIND SPEED 169 MPH - NOMINAL WIND SPEED 131 MPH 2. WIND EXPOSURE CATEGORY C 3. RISK CATEGORY II B. SEISMIC LOADS (SERVICE) 1. 5% DAMPED MAPPED ACCELERATION PARAMETER (Ss) 0.053 2. 1-SEC PERIOD MAPPED ACCELERATION PARAMETER (S1)0.024 3. 5% DAMPED SPECTRAL RESPONSE COEFF. (Sds) 0.047 4. 1-SEC PERIOD SPECTRAL RESPONSE COEFF. (Sd1) 0.034 5. SITE CLASS D (DEFAULT) 6. RISK CATEGORY II 7. IMPORTANCE FACTOR (Ie) 1.0 8. SEISMIC DESIGN CATEGORY A OPD-ABBREVIATIONS AB ANCHOR BOLT ACI AMERICAN CONCRETE INSTITUTE AFF ABOVE FINISHED FLOOR AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION AISI AMERICAN IRON AND STEEL INSTITUTE ARCH ARCHITECTURAL ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS AWS AMERICAN WELDING SOCIETY BFF BELOW FINISHED FLOOR BL BLOCK LINTEL BM BEAM BO BOTTOM OF BOM BOTTOM OF MASONRY BOS BOTTOM OF STEEL BRG BEARING CJ CONTRACTION JOINT CL CENTER LINE CLR CLEAR CMU CONCRETE MASONRY UNIT COL COLUMN CONC CONCRETE COND CONDENSER UNIT CONST CONSTRUCTION CONT CONTINUOUS DIA DIAMETER EDC ELECTRICAL DISTRIBUTION CENTER EF EXHAUST FAN EIFS EXTERIOR INSULATION AND FINISH SYSTEM EJ EXPANSION JOINT EL ELEVATION ELEC ELECTRICAL EQ EQUAL EW EACH WAY FDN FOUNDATION FF FINISHED FLOOR FS FAR SIDE FTG FOOTING FV FIELD VERIFY GA GAUGE GC GENERAL CONTRACTOR GYP GYPSUM BOARD H HEIGHT HORIZ HORIZONTAL HSA HEADED STUD ANCHOR HSS HOLLOW STRUCTURAL SHAPE INFO INFORMATION ISO ISOLATION JBE JOIST BEARING ELEVATION JST JOIST JT JOINT KSI KIPS PER SQUARE INCH L LENGTH LB POUNDS LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL LONG LONGITUDINAL MAX MAXIMUM MECH MECHANICAL MFR MANUFACTURER MIN MINIMUM MISC MISCELLANOUS MO MASONRY OPENING MTL METAL NBPS NOT BY PRECAST SUPPLIER NIC NOT IN CONTRACT NO NUMBER NS NEAR SIDE NTS NOT TO SCALE OC ON CENTER OD OUTSIDE DIAMETER OH OPPOSITE HAND OSL OUTSTANDING LEG PAF POWER ACTUATED FASTENER PC PRECAST PCF POUNDS PER CUBIC FOOT PL PLATE PLF POUNDS PER LINEAR FOOT PLUMB PLUMBING PMEJ PREMOLDED EXPANSION JOINT PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH QTY QUANITY RACK REFRIGERATION RACK REF REFER TO REINF REINFORCING REQD REQUIRED REV REVERSE RO ROUGH OPENING RTU ROOF TOP UNIT SCHED SCHEDULE SDI STEEL DECK INSTITUTE SIM SIMILAR SJI STEEL JOIST INSTITUTE SPCS SPACES SPECS SPECIFICATIONS STRUC STRUCTURAL T&B TOP AND BOTTOM THK THICKNESS TO TOP OF TOC TOP OF CONCRETE TOF TOP OF FOOTING TOGB TOP OF GRADE BEAM TOM TOP OF MASONRY TOS TOP OF STEEL TOW TOP OF WALL TRANS TRANSVERSE TYP TYPICAL UNO UNLESS NOTED OTHERWISE VERT VERTICAL W WIDTH WP WORK POINT 1/8" = 1'-0"4 ROOF FRAMING PLAN - WALL PENETRATION ISSUE BLOCK 1 PR #2 04/20/26 1 THIS DOCUMENT HAS BEEN DIGITALLY SIGNED AND SEALED BY BENJAMIN BRYAN BAILEY, P.E. ON THE DATE ADJACENT TO THE SEAL. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. 06/26/26 A B 2 F REF PLAN NOTE #2 7 S2 EXIST ROOFSLOPE DOWNREF PLAN NOTE #1 6 S2 TYP DTB GLY (2796 LBS) REF PLAN NOTE #1 EXISTING SKYLIGHT, TYP RACK ETR (FIELD VERIFY SPACING)EXISTING STEEL JOISTS AT 5'-8" ± OC, TYP5 C D EXISTING JOIST GIRDER, TYPNEW ROOFTOP CONDENSING UNIT ON CAPPED CURB, REF ARCH & REFRIGERATION5 S2 4 S2 TYP CU5 (1400 LBS) LOCATE CL OF SUPPORT CHANNEL 3" MAX FROM CL BEAM GIRDER EXIST ROOFSLOPE DOWNEXISTING CMU WALL REF PLAN NOTE #1 EXISTING BEAM GIRDER 5' - 5" ±(FIELD VERIFY SPACING)EXISTING STEEL JOISTS AT 5'-1"± OC, TYPEXISTING ROOF DECK TO REMAIN ATTACH CURB TO CHANNEL WITH #12 TEK SCREWS AT 12" OC, TYP 2 SIDES 1/8 1 1/8 1 CHANNEL TO JST THROUGH DECK, TYP C6x8.2 CONT INSTALLED OVER EXISTING ROOF DECK FIELD ADJUSTABLE CAPPED CURB PER CURB SUPPLIER EXISTING JOIST TO REMAIN PROVIDE FIELD STRUT PER 10-S2 AS REQD CONDENSING UNIT, REF REFRIGERATION NOTE: ATTACH UNIT TO UNISTRUT WITH STAINLESS STEEL BOLTS. REF UNIT SUPPLIER FOR BOLT QUANTITY, SIZE AND LAYOUT. 4" TYP EXISTING JOIST TO REMAIN, TYP C6x8.2 CONT INSTALLED OVER EXISTING ROOF DECK EXISTING ROOF DECK TO REMAIN PROVIDE FIELD STRUT PER 10-S2 AS REQD NOTE: REF 4-S2 FOR INFORMATION SHOWN BUT NOT NOTED. EXISTING ROOF DECK TO REMAIN ATTACH CURB TO CHANNEL WITH #14 TEK SCREWS AT 12" OC, TYP 2 SIDES 1/8 1 1/8 1 CHANNEL TO JST THROUGH DECK, TYP C6x13 CONT INSTALLED OVER EXISTING ROOF DECK CAPPED CURB BY CURB SUPPLIER EXISTING JOIST TO REMAIN PROVIDE FIELD STRUT PER 8-S2 OR 10-S2 AS REQD REFRIGERATION EQUIP, REF REFRIGERATION FASTEN EA SIDE OF SKID TO EA CURB SUPPORT RAIL WITH 5/8" DIA ASTM F593 TYPE 304 BOLTS AT 3/4" MOUNTING HOLES AND 1/2" DIA BOLTS AT 5/8" MOUNTING HOLES CAPPED CURB SUPPORT RAIL 4" TYP EXISTING JOIST TO REMAIN, TYP NEW STL CHANNEL INSTALLED OVER EXISTING ROOF DECK; REF 2-S2 EXISTING ROOF DECK TO REMAIN PROVIDE FIELD STRUT PER 8-S2 OR 10-S2 AS REQD NOTE: REF 6-S2 FOR INFORMATION SHOWN BUT NOT NOTED. CAPPED CURB SUPPORT RAIL REF 6-S2 FOR EQUIPMENT TO CURB SUPPORT RAIL CONNECTION ATTACH CURB TO DECKING WITH #12 TEK SCREWS AT 6" OC EXISTING ROOF DECK L3x3x3/16, TYP ATTACH ROOF DECK TO ANGLE WITH #12 TEK SCREWS AT 6" OC NON-STRUCTURAL ROOF CURB ATTACH CURB TO DECKING WITH #12 TEK SCREWS AT 6" OC ATTACH ROOF DECK TO ANGLE WITH #12 TEK SCREWS AT 6" OC L3x3x3/16, TYP EXISTING ROOF DECK CL OF JOIST 3/16 2 3/16 2 1/8 1 1/8 1 TYP SECTION A SECTION B NON-STRUCTURAL ROOF CURB EXISTING JOIST TOP CHORD 3/16 2 3/16 2 CL OF EXISTING JOIST VERIFYFIELDVERIFY FIELDVERIFYFIELD CL OF EXISTING JOIST PLAN VIEW CONCENTRATED LOAD, REF NOTE GREATER 3" OR CONCENTRATED LOAD, REF NOTE GREATER 3" OR GENERAL CONTRACTOR TO PROVIDE AND INSTALL FIELD STRUT (L2x2x3/16) EACH SIDE OF JOIST AT ALL LOCATIONS WHERE CONCENTRATED LOAD DOES NOT OCCUR WITHIN 3" OF A PANEL POINT. INSTALL ANGLE WITH ONE END AT LOCATION OF LOAD AND OTHER END AT A PANEL POINT ON THE OPPOSITE CHORD, TYP. ANGLES SHALL BE INSTALLED PRIOR TO NEW LOAD BEING APPLIED TO THE JOIST TYP EACH END EACH ANGLE1/8 1 1/8 1 TOP CHORD PANEL BOTTOM CHORD PANELNOTE: PROVIDE JOIST REINF IN ACCORDANCE WITH THIS DETAIL FOR ALL CONCENTRATED LOADS IN EXCESS OF 100 LBS. WHERE MORE THAN ONE CONCENTRATED LOAD EXISTS WITHIN A CHORD PANEL AND THE SUM OF THOSE LOADS EXCEEDS 100 LBS, PROVIDE JOIST REINFORCEMENT AS DETAILED SUCH THAT THE SUM OF THE LOADS WITHIN THE REMAINING UNSUPPORTED CHORD LENGTH DOES NOT EXCEED 100 LBS. JOIST TOP CHORD JOIST BOTTOM CHORD CONCENTRATED LOAD PROVIDE AND INSTALL VERTICAL WEB REINFORCEMENT PER 6-S2 AT ANY LOCATIONS WHERE A NEW CONCENTRATED LOAD OCCURS WITHIN 3" OF THE VERTICAL WEB JOIST TOP CHORD JOIST BOTTOM CHORD NOTE: VERTICAL WEB REINF IS ONLY REQUIRED IF EXISTING JOIST HAS VERTICAL WEB MEMBERS. 3" OR LESS 1. REF 9-S2 FOR SUPPORT FRAMING AT PIPE PENETRATION; FRAMING NOT REQUIRED FOR OPENINGS LESS THAN 10"x10"; FIELD VERIFY LOCATION ONCE UNIT HAS BEEN INSTALLED. REF REFRIG FOR EXACT SIZE AND LOCATION OF PENETRATION. 2. NEW DTA GLY ON CAPPED CURB, REF REFRIG; ALIGN ONE SIDE OF CURB WITH EXISTING JOIST GIRDER BELOW. ROOF FRAMING PLAN NOTES NOTE: 1. CONTRACTOR SHALL FIELD LOCATE ALL VERTICAL WALL REINFORCEMENT PRIOR TO CUTTING WALL. PER ORIGINAL CONSTRUCTION DOCUMENTS EXISTING REINFORCEMENT SHOULD BE (2) #6 BAR AT 24" OC AT SIM. IF FIELD CONDITIONS PROHIBIT INSTALLATION AS SHOWN, CONTACT WALMART CONSTRUCTION MANAGER IMMEDIATELY. NOTE: DO NOT CUT OPENING WITHIN 2'-0" OF EXISTING CONTROL JOINT REF ARCH (FIELD VERIFY TO OPENING EL) EXISTING VERT REINF REF NOTE #1 TYP EXISTING VERT REINF REF NOTE #1 PRE-DRILL ANGLES FOR 1/4" x 1" TAPCON SCEWS AT 16" OC, TYP FOR OPENING REF ARCH8" EXISTING REINF CELL LOCATE EXISTING WALL REINF (REF NOTE #1) AND LOCATE EDGE OF OPENING SHOWNSECTIONNOTE: CAULK ALL ANGLE EDGES AND PAINT TO MATCH. NOTE: NO REINFORCEMENT SHALL BE CUT SECTION A -12" CMU AT SIM8"EXISTING 12" CMU WALL GRIND CORNERS OF CMU WALL AS REQUIRED TO ALLOW BOTH LEGS OF ANGLE TO BE TIGHT AGAINST CMU, TYP L4x4x1/4; MITER CORNERS P (407) 661-9100F (407) 661-9101c-p.comFlorida Corporate Certificate #AA C0005262600 Maitland Center ParkwaySuite #200Maitland, FL 32751ENGINEER OF RECORD: BENJAMIN BRYAN BAILEY, P.E. 930 CENTRAL ST. KANSAS CITY, MO 64105 FL LICENSE #88408JOHNSTONBAURKHOLDERSSOCIATESc o n s u l t i n g s t r u c t u r a l e n g i n e e r s930 C 816.421.4200 ·· K C MO ENTRAL ANSASITY,64105 WWW.JBAENGR.COMSHEET: DRAWN BY: CHECKED BY: PROTO CYCLE: DOCUMENT DATE:CONSULTANTSSTIPULATION FOR REUSEPROTO:JOB NUMBER:THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT:CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.JBA NO. 25350059111/6/2026 2:34:12 PMS2 ROOFTOP EQUIPMENT PLANS AND DETAILS POI20240347BOYNTON BEACH, FL11/07/2511/07/25STORE NO: 05911 - 2769006/27/25BOYNTON BEACH, FLJSH3625 S FEDERAL HWY1/8" = 1'-0"2 ROOF FRAMING PLAN - PUMP SKID SUPPORT FRAMING 1/8" = 1'-0"3 ROOF FRAMING PLAN - RCU SUPPORT FRAMING 3/4" = 1'-0"4 REMOTE CONDENSER ROOF CURB SUPPORT 3/4" = 1'-0"5 REMOTE CONDENSER ROOF CURB SUPPORT 3/4" = 1'-0"6 REFRIGERATION EQUIPMENT SUPPORT 3/4" = 1'-0"7 REFRIGERATION EQUIPMENT SUPPORT NTS9PIPE PENETRATION SUPPORT FRAMING 6.0-23/4" = 1'-0"10 JOIST REINFORCING AT CONCENTRATED LOAD 5.0-2 3/4" = 1'-0"8 JOIST VERTICAL WEB REINFORCING AT REFRIG EQUIP 1/2" = 1'-0"1 NEW OPENING IN EXISTING WALL S3-X1 ISSUE BLOCK THIS DOCUMENT HAS BEEN DIGITALLY SIGNED AND SEALED BY BENJAMIN BRYAN BAILEY, P.E. ON THE DATE ADJACENT TO THE SEAL. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. 06/26/26