HomeMy WebLinkAboutArchitectural Plans12345678910111213
EQ EQ
36' - 0"
P215E
P215E
P215E
P215E P215EP215EP215EP215EP215E
P124E P124EP124E
36' - 0"
EQ EQ
P76U
P215EP215E
22' - 0"2' - 0"EQEQ
FENCING SHOWN WITH
DASHED LINES FOR
CLARITY
DO NOT PAINT
GLAZED
CANOPY
STRUCTURES
P215EP215E P124EP124E
NEW SIGN ........
REF 6 - A2.1
REF 4 - A2.1
P215E
P215EP215E P215E
P49E
P215E
NEW SIGNP124E
REF 3 - A2.1
P124E
P76U
P215EP215EP215E
P124E
P215EP215EP215E
NEW SIGN
REF 2 - A2.1
P76UP76UP76U
P83EP83EP124E P124EP124E
P215EP215E
NEW SIGN
REF 7 - A2.1
TYP4' - 0"DOOR
P124E
DOOR
CAP &
CORNICE
P215EP215E P215ECAP & CORNICE P215EP215E
P215E
CAP &
CORNICE
P215EP215E
CAP & CORNICE P215EP215E
CAP &
CORNICE
P215EP215E
CAP & CORNICE
P215E
CAP &
CORNICE P215E
CAP &
CORNICE
P215E P215E
P215E
CAP &
CORNICE
REPLACE EXISTING TRANSLUCENT
GLAZED WALL SYSTEM. REF SPECS
REPLACE
EXISTING
TRANSLUCENT
GLAZED WALL
SYSTEM. REF
SPECS
_____
A2
10
NEW SIGN
REF 8 - A2.1P124E
P215EP215E
P124E
NEW SIGN
REF 11 - A2.1
P215E
P124EP124E
P83E
GUTTER &
DOWNSPOUT
ROOF
ETR
ROOF ETR
P83E
GUTTER &
DOWNSPOUT TYP4' - 0"EXISTING
TENANT SIGNEQEQCLEQEQCL
100' - 0''
FF EL
132' - 8''
TOM
NEW SIGN
EQEQ
9' - 2"10' - 11"3' - 4"3' - 4"EQEQ20' - 0"
27' - 5"
8.02
8.02
P124E
_____
OPA2
2
0.80.91.7
2' - 0"EQEQ
600' - 7"
P83E
P124E
P215E
P83E
ALL ENTRY BOLLARDS TO RECEIVE
BLUE SLEEVES TO MATCH P76U
CLCL
2' - 0"2' - 0"
ABCDEFGHI
P215E
HOOD
P215E
P215E
CAP &
CORNICE CAP &
CORNICE
P215E
DOOR
P215EP215E
FENCING SHOWN WITH DASHED LINES FOR
CLARITY
P215E
P215EP215E
CAP &
CORNICE
P134EP215E
P215EP215E
P215E
CAP &
CORNICE
P215E
CAP &
CORNICE
P124E
DOOR
P124E P124E
P215E
CAP &
CORNICE
P215E P215EP215E P124E 8.02P134E
P215E
CAP &
CORNICE
P215E
P215E
P215E
P215E
CAP &
CORNICE
P134E
CAP &
CORNICE
_____
A2
9
P215EP215EP215EP124EP124EP124EP124E
P215E
ROOF
123' - 4''
TOM
100' - 0''
FF EL TYP4' - 0"P215E
P215E
A.3A.9B.5C.2
P215E P124EP135E
1 2 3 4 5 6 7 8 9 10 11 12 13
FENCING SHOWN WITH
DASHED LINES FOR
CLARITY
P215E
P215EP215E
CAP &
CORNICE
P36E
EXISTING JIB
CRANE
_____
A2
6
P215EP215E
SCUPPER (TYP)
P215E
P215EP215E
GUTTER &
DOWNSPOUT (TYP)
P215EP215E P215E
DOOR
P215EP215E
CAP &
CORNICE
P215EP215E
CAP &
CORNICE
P215EP215E
CAP &
CORNICE
P215EP215E
CAP &
CORNICE
P215EP215E
CAP &
CORNICE
P215E P215E P215E
DOOR
P215E
DOOR
P215E P215E P215E P215E
P215E
HOOD (TYP)
DOOR DOOR
P215E
P215EP215E
COMPACTOR
DOOR
P215E P215E P215E
P215E
P215EP215EP215EP215E
P5E
EXISTING ROOF
ACCESS LADDER
P215EP215E
GUTTER &
DOWNSPOUT
(TYP)
ROOF
100' - 0''
FF EL
122' - 8''
TOM
0.9 1.7
P215E P215E
HOOD, TYP
P215E P215E
A B C D E F G H I
_____
A2
8
CAP &
CORNICE
P215E
P124E
CAP &
CORNICE
P215EP215E
CAP &
CORNICE
P215EP215E
CAP &
CORNICE
P215EP215E
CAP &
CORNICE
P215E
P215E P215E
P124EP124EP215EP215E
P215E
P124EP124E
P215EP215E DOOR
COMPACTOR
DOORP215E P215E
P215E
HOOD
P124E
P215EP215E
100' - 0''
FF EL TYP4' - 0"_____
OPA2
3
A.3 A.8 A.9 B.5 C.2
130' - 8''
TOM
P215E
P124E
P215EP215E
P215EP215E
P215E
P124EP124E TYP4' - 0"1' - 6"1' - 6"P124E
DOOR
38' - 0"
NEW SIGN
TYP
6' - 0"
CL CL
P215E
CAP &
CORNICEP215E
CAP &
CORNICE
REF 5 - A2.1
CL
NEW SIGN
REF 10 - A2.1
NEW SIGN
REF 13 - A2.1
NEW SIGN
REF 9 - A2.1EQEQCL
TYP
1' - 3"
4' - 9"
100' - 0''
FF EL
124' - 0''
TOM
9' - 4"CLEQEQP76U 4' - 0"P215E
P215EP215E
P124EP124E
P124E
P215E
CAP &
CORNICE
P215E
CAP &
CORNICE
DOOR
P124E
TYP
6' - 0"
CL
CL
100' - 0''
FF EL
124' - 0''
TOM
P215E GUTTER &
DOWNSPOUT
(TYP)
P124E
P215E
SCUPPERS
(TYP)
1' - 3"EQEQNEW SIGN
REF 10 - A2.1
P215E
NEW SIGN
REF 13 - A2.1
P124E
CAP &
CORNICE
P76U
P83E P124EP83EP83E
DOOR
P124E
P215EP215EP215E
P83E
GUTTER &
DOWNSPOUT
TYP4' - 0"ROOF
ETR
P215EP215E
P124EP124E
P124E
P215E
CAP &
CORNICE
P215E P215EP215E
P124E P124E
DOOR
P215E
GUTTER &
DOWNSPOUT (TYP)
P215E
100'-0''
FF EL
126'-8''
TOM
TYP4' - 0"P215E P215E
SCUPPER
(TYP)
P83E
P83E
P124E
P76U
GUTTER &
DOWNSPOUT
P215EP215E
CAP &
CORNICE
P215EP215EP215E
P76U
P83E
P215E
ROOF
ETR 2' - 2"
P209
67
P83E
DOOR
P83E
P83EP83E
P83EP215E
CAP &
CORNICE
P83E P83E
CAP &
CORNICE
P76U
P83E
NEW SIGN
REF 1 - A2.1
100' - 0''
FF EL P83E
8.02
12
A2.1
_______
TOM
133' - 4"
EQEQ
68' - 0"CLEQEQP215E
CAP (TYP)
P215E
CAP (TYP)FIELD VERIFY WALL PRIOR
TO STARTING WORK
P124EP124E P124EP124E
SHEET:
DRAWN BY:
CHECKED BY:
PROTO CYCLE:
DOCUMENT DATE:CONSULTANTSSTIPULATION FOR REUSEPROTO:JOB NUMBER:THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT:CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.NOT FOR
CONSTRUCTIONP (407) 661-9100F (407) 661-9101c-p.comFlorida Corporate Certificate #AA C0005262600 Maitland Center ParkwaySuite #200Maitland, FL 327519/16/2024 8:12:45 AMA2
EXTERIOR
ELEVATION
PN/YC20230491BOYNTON BEACH, FL07/29/2407/29/24STORE NO: 02789 - 24520801/26/24BOYNTON BEACH, FLBP3200 OLD BOYNTON ROAD 1" = 20'-0"1 FRONT ELEVATION
1" = 20'-0"2 LEFT ELEVATION
1" = 20'-0"5 REAR ELEVATION
1" = 20'-0"7 RIGHT ELEVATION
1" = 20'-0"4 AUTO CARE FRONT ELEVATION
1" = 20'-0"6 AUTO CARE REAR ELEVATION
MONUMENT SIGN 1
SITE SIGNAGE: EXISTINGSITE PLAN
BM 996 ASHEN TAN
BM CUSTOM COLOR WALMART BLUE
COLOR NAME
P83E
P#
P76U
P215E
BM 1022 MAPLE SHADOWS
BM 1034 CLAYP124E
BM HC-72 BRANCHPORT BROWNP217E
SW 7004 SNOWBOUNDP140E
P5E BM SAFETY YELLOW #10
P36E BM 2118-20 TOUCAN BLACK
COLOR LEGEND DEMOLITION NOTES
1.
2.
•
NOT USED
REMOVAL OF BUILDING MOUNTED ITEMS, SHOWN OR
NOTED TO BE DEMOLISHED OR AS REQUIRED BY SCOPE
OF WORK, SHALL OCCUR PRIOR TO PAINTING BUILDING
COORDINATE DEMOLITION WORK SO EXTERIOR
PAINTING WILL OCCUR PRIOR TO INSTALLATION OF
BUILDING MOUNTED ITEMS
HATCH LEGEND
EIFS AREA TO BE RESURFACED
(REF SPEC)
EIFS AREA EXISTING TO
REMAIN
SHEET NOTES
1.
2.
3.
4.
5.
6.
7.
•
•
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
•
PATCH AND REPAIR EXTERIOR WALL SURFACES,
DAMAGED OR EXPOSED DUE TO REMOVAL OF BUILDING
MOUNTED ITEMS, TO MATCH ADJACENT AS REQUIRED
REFER TO DETAILS ON SHEET A2.1 FOR SUBSTRATE AND
FINISH REQUIREMENTS AT LOCATIONS OF BUILDING
MOUNTED SIGNS
RESURFACE EXISTING EIFS WHERE SHOWN (HATCHED
AREA)
NOT USED
PRIOR TO PAINTING WALL AT LOCATION(S) OF LIT
ID/LOGO SIGN(S), COORDINATE SCOPE OF WORK WITH
WALMART CM
IF PAINTING ADJACENT WALLS PAINT HOLLOW METAL
STEEL DOORS, FRAMES, AND DOWNSPOUTS, EXPOSED
METAL FLASHING, HANDRAILS, AND EXPOSED
MISCELLANEOUS STEEL TO MATCH PRIMARY ADJACENT
BUILDING COLOR UNO
PAINT ANY ROOFTOP GAS PIPING P5E
WHERE EXTERIOR WALL IS BEING PAINTED, GAS PIPE
ALONG SIDE WALL TO GRADE SHALL MATCH
ADJACENT BUILDING
DO NOT PAINT METER OR VALVES
IF PAINTING ADJACENT WALLS PAINT CANOPY
STRUCTURAL STEEL AND FLASHING TO MATCH
ADJACENT WALL
WHERE CANOPIES ARE VISIBLE TO AND ACCESSED BY
CUSTOMERS, PAINT UNDERSIDE OF CANOPY DECK
DO NOT PAINT CANOPY DECK IF NOT PREVIOUSLY
PAINTED
PAINT ALL EXTERIOR ENTRY BOLLARDS TO MATCH
EXISTING COLOR UNLESS NOTED TO RECEIVE PLASTIC
BOLLARD SLEEVE
NOT USED
DO NOT PAINT LED WALL PACK HOUSINGS
NOT USED
NOT USED
NOT USED
NOT USED
PAINT JIB CRANE P36E ON JIB BOOM, P5E ON
HANDRAILS
PAINT SPRINKLER VALVES P21E
DO NOT PAINT OVER SIGHT GLASS OR FIRE ALARM
BELL
KEEP ALL EXISTING WHITE ROLLUP DOORS AS ETR P140E
WITH TOUCHUPS AS REQUIRED IN HIGH CUSTOMER
VISIBILTY AREA
WRAP PAINT AROUND THE BACKSIDES OF ALL PILASTERS,
CMU WALLS, ALL PROTRUDING ELEMENTS AND SOFFITS TYP
AT ALL ELEVATIONS.
P140E
1" = 20'-0"9
GM VESTIBULE
LEFT ELEVATION
1" = 20'-0"3 SEASONAL SHOP REAR ELEVATION
1" = 20'-0"8
GR VESTIBULE
RIGHT ELEVATION
1" = 10'-0"10 ENLARGED ELEVATION
OUTDOOR
<AUTO CARE
AUTO CARE,
NUMERALS,
TIRE AND OIL
CHANGE
HOME &
PHARMACY
WALMART*
PICKUP GROCERY
MONUMENT
SIGN
1" = 20'-0"11 PERIMETER WALL ELEVATION
PERIMETER
WALL
PERIMETER
WALL
EIFS RESURFACING: RESURFACE THE FULL EXTENT OF
EIFS PLANE. THE CONTRACTOR IS TO MAINTAIN REVEALS
OR JOINTS AFFECTED. REF SPECS
P33E BM 2149-70 WHITE CHOCOLATE
P21E BM SAFETY RED #20
KEYNOTE
8.02 HOLLOW METAL DOOR AND FRAME
ISSUE BLOCK
1 PR#1 09/13/24
GOLDEN CORRAL
OUTPARCEL COLOR LEGEND
ALL DETAILS WERE REVISED DUE TO COLOR
SCHEME DURING PR#1
1
•
THE FOLLOWING LEGEND HAS BEEN REVISED
DURING PR#1:
COLOR LEGEND
•
THE FOLLOWING LEGEND HAS BEEN ADDED
DURING PR#1:
GOLDEN CORRAL
11/26/24
SIGNAGE GENERAL NOTES
1.
2.
A.
B.
C.
D.
E.
3.
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
SIGNAGE FURNISHED BY WAL-MART AND INSTALLED BY
SIGN CONTRACTOR
ALL EXISTING WALMART EXTERIOR SIGNAGE IS TO REMAIN
IN PLACE ON THE BUILDING UNTIL THE GC SIGN COMPANY
IS ONSITE
THE EXISTING SIGNAGE WILL THEN BE REMOVED,
PATCH AND REPAIR WORK WILL BE COMPLETED AT
SIGN LOCATIONS, AND SIGNAGE WILL BE INSTALLED
PER PLANS
A TEMPORARY BANNER WILL BE INSTALLED PRIOR TO
REMOVAL OF EXISTING EXTERIOR SIGNAGE
BANNER WILL REMAIN IN PLACE UNTIL ALL
MODIFICATIONS AND/OR REPAIRS HAVE BEEN
COMPLETED AND SIGNAGE IS INSTALLED
TEMPORARY BANNER WILL BE APPROXIMATELY 125 SF
(5'X25')
EXTERIOR SIGN WORK NEEDS TO BE SCHEDULED,
COORDINATED, AND COMPLETED DURING WEEK 6 OF
THE CONSTRUCTION SCHEDULE
GENERAL CONTRACTOR RESPONSIBILITIES
BY END OF FIRST WEEK OF CONSTRUCTION, REVIEW
EXISTING CONSTRUCTION WHERE SIGN(S) WILL BE
INSTALLED
IF EXISTING CONDITIONS DO NOT MATCH SIGN
ATTACHMENT DETAILS SHOWN, REQUEST APPROVAL
FROM CONSTRUCTION MANAGER TO SUBMIT RFI IN
ACCORDANCE WITH SECTION 01255
NOTE DIFFERENCES IN CONSTRUCTION, INCLUDING
DIMENSIONS, AND INCLUDE PHOTOGRAPHS FOR
CLARIFICATION
PROVIDE SUBSTRATE SUITABLE FOR INSTALLATION OF
SIGNAGE, REFER TO SIGN DETAILS FOR LIGHTED
ID/LOGO SIGNS
PROVIDE JUNCTION BOXES AND CIRCUITRY TO
"Walmart" , "spark" and "Pickup" SIGNAGE
EXISTING (8) BOXES FROM "WALMART" SIGNAGE MAY
BE REUSED
PROVIDE JUNCTION BOXES AND CIRCUITRY TO
TENANT SIGNAGE LOCATION SHOWN, REFER TO
ELECTRICAL
INSTALL ACCESS DOORS AND FRAMES IN GYPSUM
BOARD CEILINGS IF REQUIRED BY RELOCATION OF
EXISTING TENANT SIGNAGE
VERIFY VOLTAGE AT CIRCUITS FEEDING LIGHTED
SIGNAGE, REFER TO ELECTRICAL
MAKE FINAL TERMINATIONS ON LIGHTED SIGNAGE
REMOVE ALL LIT ID/LOGO SIGNS AND UNLIT EXTERIOR
STUD MOUNTED BUILDING SIGNS, UNLESS NOTED
OTHERWISE
MAKE REQUIRED EXTERIOR WALL PENETRATIONS,
INSTALL CONDUIT, AND SEAL PENETRATIONS PER
SPECIFICATION SECTION 07900
INSTALL SIGNAGE PER DETAILS
26.27 SF
9' - 8 3/8"2' - 8 1/2"2'-0"15
A2.1
_______
60.74 SF
22' - 5 1/8"2' - 8 1/2"2' - 0"15
A2.1
_______
20.67 SF2' - 0"10' - 4"
17
A2.1
_______
16.25 SF
10' - 10"1' - 6"17
A2.1
_______PLYWD HEIGHTPER SIGN SIZE6"PLYWOOD LENGTH PER SIGN SIZE
(TO NEXT AVAILABLE STUD)6" 6"6"EXISTING METAL
STUDS (BEYOND)
REMOVE EXISTING
SHEATHING IN SIGN
MOUNTING AREA (TO
NEXT AVAILABLE STUD)
AND REPLACE WITH
5/8" EXTERIOR GRADE
FIRE-TREATED PLYWOOD
REMOVE EXISTING EIFS
6" PAST AREA OF
SHEATHING REMOVAL
PRIOR TO PERFORMING THIS WORK, VERIFY EXISTING SUBSTRATE
MATERIAL. IF EXISTING SUBSTRATE IS CMU OR PLYWOOD (5/8"
OR THICKER), SUBSTRATE REPLACEMENT IS NOT REQ'D
INSTALL EIFS WHERE
EXISTING EIFS WAS
REMOVED - ENSURE FINISH
COAT IS FLUSH WITH
ADJACENT RESURFACED
EXISTING EIFS
RESURFACE EXISTING EIFS TO EXTENTS SHOWN
ON BUILDING ELEVATIONS TO ENSURE CONSISTENT
FINISH TEXTURE, REF EIFS SPECIFICATION
24.75 SF
12' - 4 1/2"2' - 0"17
A2.1
_______
EXISTING
FRAMING
PLASTIC NON-ILLUMINATED
CHANNEL LETTER
PLASTIC MOUNT FOR
ALL-THREAD STUD, TYP
INSTALL 1/8" DIA ALL-
THREAD STUDS INTO
PLASTIC MOUNTS, TYP
3/8" DIA HOLE FILLED
WITH ADHESIVE
SEALANT, TYP
MOUNTING HOLE PATTERNS FOR NON-
ILLUMINATED SIGN INSTALLATION
PROVIDED BY WALMART
"ADHESIVE SEALANT" IS TO BE
PRODUCT LN-950 BY LIQUID NAILS OR
SIMILAR POLYURETHANE
CONSTRUCTION ADHESIVE, MEETING
ASTM D3498 AND C557 STANDARDS,
EXTERIOR APPLICATION, WEATHER
RESISTANT, LOW VOC, WITH A
MINIMUM SHEAR STRENGTH OF 250
PSI
PRIOR TO PERFORMING THIS WORK,
VERIFY EXISTING SUBSTRATE
MATERIAL
IF EXISTING SUBSTRATE IS CMU OR
PLYWOOD (5/8" OR THICKER),
SUBSTRATE REPLACEMENT IS NOT
REQUIRED
VARIESREFER TO SIGNAGE
GENERAL NOTES FOR
ADDITIONAL REQUIREMENTS
1/4" SPACER BETWEEN
FACE OF BUILDING
FINISH AND CHANNEL
LETTER
THROUGH WALL
PROTECTION TUBE
FURNISHED BY WALMART
INSTALLED BY GC PER
MFR RECOMMENDATIONS
FULL BED OF MULTI-
COMPONENT SEALANT AT
PERIMETER OF CONDUIT
INSTALL LETTER BACK
PRIOR TO INSTALLATION
INDIVIDUAL PLASTIC
ILLUMINATED CHANNEL
LETTERS
INSTALL LETTER FACES
WITH SET SCREWS,
TYP LOCATE ANCHORS AND
WIRING/CONDUIT PENETRATIONS
PER SIGN ATTACHMENT TEMPLATE
PROVIDED BY WALMART
LOCATE CONDUIT PENETRATION
4'-0" MAX FROM UNISTRUT
PROVIDE ONLY ONE ROOF
PENETRATION FOR ALL WHIPS
EXISTING ROOFING SYSTEM
PENETRATIONS AND SEALANT
AT LOW VOLTAGE WIRE
3/4" LIQUID TIGHT FLEXIBLE METAL
CONDUIT
SIGNAGE CONDUIT FLASHING AT LOW VOLTAGE
WIRE PENETRATIONS FURNISHED BY WALMART
INSTALLED BY GC PER MFR RECOMMENDATIONS
SEALANT AT PERIMETER AND ANCHORS OF
REMOTE POWER SUPPLY ENCLOSURE
REMOTE POWER SUPPLY ENCLOSURE
EXISTING
WATERPROOFING MEMBRANE
HILTI HPS 1/4" X 2 5/8"
SLEEVE ANCHOR
PROVIDED BY WALMART
AT EACH SIGN
CONNECTION POINT
INSTALLED BY GC
PRE MOLDED PIPE FLASHING ATTACHED
PER ROOFING MFR RECOMMENDATIONS
CONT SEALANT
LOW VOLTAGE WIRE
CONDUIT TO PANEL
BOARD REF ELECTRICAL
8" MINEXISTING CMU
PLASTIC NON-ILLUMINATED
CHANNEL LETTER BY
WALMART
INSTALL 1/8" DIA ALL-THREAD
STUDS INTO PLASTIC
MOUNTS PRIOR TO SIGN
INSTALLATION
3/8" DIA HOLE FILLED WITH
ADHESIVE SEALANT. COAT
ALL-THREAD STUD WITH
ADHESIVE SEALANT PRIOR
TO WALL ATTACHMENT
MOUNTING HOLE PATTERNS FOR
NON-ILLUMINATED SIGN INSTALLATION
PROVIDED BY WALMART
PLASTIC MOUNT FOR ALL-
THREAD STUD TYP BY WALMART
"ADHESIVE SEALANT" IS TO
BE PRODUCT LN-950 BY
LIQUID NAILS OR SIMILAR
POLYURETHANE
CONSTRUCTION ADHESIVE,
MEETING ASTM D3498 AND
C557 STANDARDS,
EXTERIOR APPLICATION,
WEATHER RESISTANT,
LOW VOC, WITH A MINIMUM
SHEAR STRENGTH OF 250
PSI VARIES11.35 SF
8' - 6 1/8"1' - 4"1' - 0"17
A2.1
_______1' - 0"2' - 4"
2.33 SF
17
A2.1
_______1' - 0"6' - 11"
9.33 SF
17
A2.1
_______1' - 4"ADDRESS SIGNAGE
NOTE:
SQUARE FOOTAGE NOT
INCLUDED IN BUILDING
SIGNAGE SCHEDULE1' - 0"3' - 8"
15
A2.1
_______2' - 6"6.25 SF
2' - 6"
TYP
17
A2.1
_______
REF CIVIL PLANS
FOR SIGN
LOCATION
EXISTING LIGHT
POLE
2' - 0"5' - 0"18' - 0"EXISTING ROOFING SYSTEM
1 1/2" WATER DRAINAGE EIFS ON
5/8" EXTERIOR PLYWOOD
SHEATHING
STEEL JOIST
REF STRUCTURAL
TO JUNCTION BOX
REF ELECTRICAL
PRE MOLDED PIPE FLASHING BY
ROOFING INSTALLER
SNAPTOGGLE BB ANCHOR (1/4 - 20)
PROVIDED BY WALMART AT EACH
SIGN CONNECTION POINT
INSTALLED BY GC
WATERPROOFING MEMBRANE
SEALANT AT LOW VOLTAGE WIRE
PENETRATIONS
3/4" CONDUIT TO PANEL
BOARD
REF ELECTRICAL
NOTE:
PIPE FLASHING IS REQUIRED
FOR INSTALLATION ABOVE
ROOF ONLY
REF ELECTRICAL FOR JUNCTION
BOX AND CONDUIT
INSTALLATION REQUIREMENTS
THROUGH WALL PROTECTION TUBE
FURNISHED BY WALMART
INSTALLED BY GC.
INSTALL PER MFR
RECOMMENDATIONS
THROUGH WALL PROTECTION
TUBE FURNISHED BY WALMART
INSTALLED BY GC INSTALL PER
MFR RECOMMENDATIONS
FULL BED OF MULTI-
COMPONENT SEALANT AT
PERIMETER OF CONDUIT
SIGN CAN WITH .080 ALUMINUM
BACKING BY WALMART
PILL CABINET WITH .080 ALUMINUM
BACKING BY WALMART
DRILL HOLE AND FEED WHIP
THROUGH PARAPET, TYP
FULL BED OF
MULTI-COMPONENT SEALANT
AT PERIMETER OF CONDUIT
SNAPTOGGLE BB ANCHOR
(1/4 - 20)
PROVIDED BY WALMART AT
EACH SIGN CONNECTION
POINT INSTALLED BY GC
NOTE:
LOCATE ALL-THREADS PER
SIGN ATTACHMENT TEMPLATE
PROVIDED BY WALMART
NOTE:
LOCATE CONDUIT PENETRATION
4'-0" MAX FROM POWER SUPPLY
ENCLOSURE. PROVIDE ONLY ONE
ROOF PENETRATION FOR ALL
WHIPS.
3/4" LIQUID TIGHT FLEXIBLE METAL
CONDUIT ℄REMOTE POWER
SUPPLY ENCLOSURE
THROUGH WALL
PROTECTION TUBE
FURNISHED BY WALMART
INSTALLED BY GC. INSTALL
PER MFR
RECOMMENDATIONS
LOW VOLTAGE WIRE
SEALANT ALL AROUND
LOW VOLTAGE WIRE
SIGNAGE CONDUIT FLASHING AT LOW
VOLTAGE WIRE PENETRATIONS. PROVIDED
BY WALMART INSTALLED BY GC.
REF INSTALLATION INSTRUCTIONS.
REMOTE POWER SUPPLY
ENCLOSURE
SEALANT AT PERIMETER AND
ANCHORS OF REMOTE POWER
SUPPLY ENCLOSURE
PREFERED MOUNTING HEIGHT 3' TO 4' ABOVE ROOF SURFACE12" MIN 12" MINTOP OF PARAPET8" MINMETAL STUDS
INSTALL LETTER BACK PRIOR
TO INSTALLATION
REMOVE EXISTING EIFS AT NEW
BADGE LOCATION
WHITE LETTERS
FLEX FACE
COLOR PMS
285C BLUE
YELLOW SPARK,
COLOR PMS 1235C
P215E
P124E
CAP & CORNICE
P124E
P124E
REPLACE FACE ON
EXISTING SIGN CABINET
REPAIR
EXISTING SIGN
STRUCTURE
32.22 SF3' - 4"2' - 6"9' - 8"
INTERNALLY
ILLUMINATED
A.
B.
C.
NOTE TO SIGN INSTALLER:
ALL PRIMARY MOUNTING HOLES MUST BE UTILIZED
IF MOUNTING THROUGH PRIMARY HOLE IS OBSTRUCTED BY
REBAR, METAL STUDS, CHANNELS, OR OTHER MISC METAL,
SEAL PRIMARY HOLE IN SIGN CAN AND MOUNT THROUGH THE
NEAREST ALTERNATE MOUNTING HOLE
PRIMARY HOLES ARE INDICATED WITH PREDRILLED HOLES
NOTE :
ALL SIGN PENETRATIONS ABOVE
ROOF LEVEL MUST BE A CLEAR
MINIMUM OF 8" ABOVE DECK
14
A2.1
_______
298.00 SF1' - 3"5' - 6"8' - 0"28' - 7 1/2"1' - 6"7' - 1 1/2"
37' - 3"
INTERNALLY ILLUMINATED
T Y P
6 0 °
T Y P2' - 7 3 /8 "12
A2.1
_______
SHEET:
DRAWN BY:
CHECKED BY:
PROTO CYCLE:
DOCUMENT DATE:CONSULTANTSSTIPULATION FOR REUSEPROTO:JOB NUMBER:THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT:CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.NOT FOR
CONSTRUCTIONP (407) 661-9100F (407) 661-9101c-p.comFlorida Corporate Certificate #AA C0005262600 Maitland Center ParkwaySuite #200Maitland, FL 327519/16/2024 8:13:04 AMA2.1
EXTERIOR
SIGNAGE
YC/PN20230491BOYNTON BEACH, FL07/29/2407/29/24STORE NO: 02789 - 24520801/26/24BOYNTON BEACH, FLBP3200 OLD BOYNTON ROADEXISTING SIGNAGE SCHEDULE
SIGN QTY TYPE LIGHTED COLOR SIZE
INDIVIDUAL
AREA TOTAL AREA
FRONT ELEVATION
WALMART* 1 EXISTING LED WHITE/YELLOW 5'-6" / 8'-0" 299.04 SF 299.04 SF
HOME & PHARMACY 1 EXISTING NO WHITE 2'-0'' 61.85 SF 61.85 SF
<AUTO CENTER 1 EXISTING NO WHITE 1'-6'' 19.43 SF 19.43 SF
LAWN & GARDEN 1 EXISTING' NO WHITE 2'-0'' 41.02 SF 41.02 SF
PICKUP 1 EXISTING NO WHITE 2'-0'' 20.61 SF 25.69 SF
GROCERY 1 EXISTING NO WHITE 2'-0' 25.63 SF 25.63 SF
BEER WINE SPIRITS 1 EXISTING NO WHITE 1'-0'' 15.89 SF 35.33 SF
FRONT ELEVATION 7 507.99 SF
AUTO CENTER FRONT ELEVATION
AUTO CENTER 1 EXISTING NO WHITE 1'-6'' 17.75 SF 17.75 SF
TIRE 2 EXISTING NO WHITE 1'-0'' 2.38 SF 4.76 SF
LUBE 1 EXISTING NO WHITE 1'-0'' 3.13 SF 3.13 SF
AUTO CENTER FRONT
ELEVATION 4 25.64 SF
TOTAL BUILDING SIGNAGE 11 533.63 SF
NEW SIGNAGE SCHEDULE
SIGN QTY TYPE LIGHTED COLOR SIZE
INDIVIDUAL
AREA TOTAL AREA
FRONT ELEVATION
WALMART* 1 NEW LED WHITE/YELLOW 5'-6" / 8'-0" 298.00 SF 298.00 SF
GROCERY 1 NEW NO WHITE 2'-0' 26.27 SF 26.27 SF
PICKUP 1 NEW LED WHITE 2'-6'' 32.22 SF 32.22 SF
HOME & PHARMACY 1 NEW NO WHITE 2'-0'' 60.74 SF 60.74 SF
OUTDOOR 1 NEW NO WHITE 2'-0'' 20.67 SF 20.67 SF
<AUTO CARE 1 NEW NO WHITE 1'-6'' 16.25 SF 16.25 SF
WINE & SPIRITS 1 NEW NO WHITE 1'-0'' 11.35 SF 11.35 SF
ADDRESS NUMERALS 3200 4 NEW NO BLACK 1'-0" 0.00 SF 0.00 SF
FRONT ELEVATION 11 465.50 SF
AUTO CARE SIGNAGE
AUTO CARE 1 NEW NO WHITE 2'-0'' 24.75 SF 24.75 SF
TIRE 4 NEW NO BLACK 1'-0" 2.33 SF 9.32 SF
OIL CHANGE 2 NEW NO BLACK 1'-0" 9.33 SF 18.66 SF
AUTO NUMERALS 6 NEW NO BLACK 2'-6'' 6.25 SF 37.50 SF
AUTO CARE SIGNAGE 13 90.23 SF
TOTAL BUILDING SIGNAGE 24 555.73 SF
1/4" = 1'-0"2 2'-0" GROCERY
1/4" = 1'-0"3 2'-0" HOME & PHARMACY
1/4" = 1'-0"4 2'-0" OUTDOOR
1/4" = 1'-0"6 1'-6" < AUTO CARE
3/8" = 1'-0"18 SUBSTRATE AT NEW SIGNAGE
1/4" = 1'-0"5 2'-0'' AUTO CARE
1 1/2" = 1'-0"15
SIGN ATTACHMENT AT EIFS AND
METAL STUD WALL
1 1/2" = 1'-0"14 PICKUP SIGN ATTACHMENT ABOVE LINE
1 1/2" = 1'-0"17 SIGN ATTACHMENT AT CMU WALL
SIGNAGE FOR REFERENCE ONLY
SIGNAGE WILL BE SUBMITTED UNDER SEPERATE PERMIT
1/4" = 1'-0"8 1'-0" WINE SPIRITS
1/4" = 1'-0"10 1'-0" TIRE
1/4" = 1'-0"9 1'-0" OIL CHANGE
1/4" = 1'-0"11 1'-0" BLACK ADDRESS NUMERAL
1/4" = 1'-0"13 2'-6" AUTO NUMERALS
3/16" = 1'-0"16
PICKUP BANNER AT
EXISTING LIGHT POLE
1" = 1'-0"12 MAIN ID SIGN ATTACHMENT
3/16" = 1'-0"19 MONUMENT SIGN
1/4" = 1'-0"7 2'-6" PICKUP
20.61
15.89
483.47
509.11
ISSUE BLOCK
1 PR#1 09/13/24
1/4" = 1'-0"1 5'-6" WALMART SIGN
1
1 1
1
1
1
1
NEW SIGN SCHEDULE HAS
BEEN REVISED DURING PR#1
1
11/26/24
12
TYP4' - 0"4.08
P215E
4.08CANOPY PREFINISHED BY
VENDOR TO MATCH P162EP217E
ROOF LINE
100' - 0"
FF EL
EXT'G BLDG NEW ADDITION
P215E
2
OPA3
_______3
OPA3
_______
COLUMNSP124E P215E
4.09
P215E
4.08
7.50
0.80.91.7
4.04
TYP
P215E
P124E
P215E
P215E
4.08
4.08
P124E
4.08
P215E
P215E
7.22
TOM
122' - 8"
P215E
TOM
120' - 8"
7.04
7.22
P215E
P217E
7.50
7.50
B C
9' - 0"4.08 4.08
ROOF LINE P215E
7.22
P134EP124E 4' - 0"100' - 0"
FF EL
EXT'G BLDG NEW ADDITION EXT'G BLDGNEW ADDITION
7.19
1
OPA3.1
_______2
OPA3.1
_______3
OPA3.1
_______
_____
OPA4
6
P215E
7.09
TYP
P215EP215E
P215E P215E
4.09
P215E
4.08
A.3 A.8 A.9 B.5 C.2
P124E
P215E P215E
19' - 4"TOM
120' - 8"
TOM
122' - 8"
4.08
P124E
7.04
P215EP215E
7.22
P215E
3
OPA3.2
_______
4.084.08
P215E
7.21
TYP
7.22 7.227.22
P215E
4.08 NEW ROOF
ACCESS LADDERP215E
8.02
100' - 0"
FF EL
122' - 8"
TOM
ROOF LINE
EXT'G BLDG NEW ADDITION
2' - 8"
4
OPA3.1
_______1
OPA3.2
_______
0.9
4.08
P215E
P215E
P215E
TOM
120' - 8"
P215E
P215E P215E
P215EP215E
7.22
7.04 7.22
P5E
7.22
P124E P215E
4.084.08
100' - 0"
FF EL
ROOF LINE
P215E
7.22
1
OPA3
_______4' - 0"P215E
A.3A.8A.9
4.09
P215E
4.08
P124E
P215E
P215E
P215E
P215E
TOM
122' - 8"
TOM
120' - 8"
7.04
4.08
7.50
7.22
SHEET:
DRAWN BY:
CHECKED BY:
PROTO CYCLE:
DOCUMENT DATE:CONSULTANTSSTIPULATION FOR REUSEPROTO:JOB NUMBER:THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT:CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.NOT FOR
CONSTRUCTIONP (407) 661-9100F (407) 661-9101c-p.comFlorida Corporate Certificate #AA C0005262600 Maitland Center ParkwaySuite #200Maitland, FL 327519/16/2024 8:13:41 AMOPA2
OP
EXTERIOR
ELEVATIONS
OB20230491BOYNTON BEACH, FL07/29/2407/29/24STORE NO: 02789 - 24520801/26/24BOYNTON BEACH, FLBP3200 OLD BOYNTON ROAD 3/16" = 1'-0"2 OP FRONT ELEVATION
3/16" = 1'-0"3 OP RIGHT ELEVATION
3/16" = 1'-0"4 OP REAR ELEVATION
3/16" = 1'-0"1 OP LEFT ELEVATION
COLOR NAMEP#
P5E SAFETY YELLOW
COLOR LEGEND DEMOLITION NOTES
•
1. NOT USED
2. REMOVAL OF BUILDING MOUNTED ITEMS, SHOWN OR
NOTED TO BE DEMOLISHED OR AS REQUIRED BY SCOPE OF
WORK, SHALL OCCUR PRIOR TO PAINTING BUILDING
COORDINATE DEMOLITION WORK SO EXTERIOR
PAINTING WILL OCCUR PRIOR TO INSTALLATION OF
BUILDING MOUNTED ITEMS
KEYNOTES
4.04 CONTROL JOINT, TYP, REF STRUCTURAL
4.08 SPLIT FACE CMU
4.09 SMOOTH FACE CMU
7.04 METAL FASCIA COVER
7.09 METAL DOWNSPOUT, PREFINISHED, UNLESS NOTED
OTHERWISE
7.19
7.21
7.22 EXTERIOR INSULATION FINISH SYSTEM
7.50
8.02 HOLLOW METAL DOOR AND FRAME
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
PATCH AND REPAIR EXTERIOR WALL SURFACES,
DAMAGED OR EXPOSED DUE TO REMOVAL OF BUILDING
MOUNTED ITEMS, TO MATCH ADJACENT AS REQUIRED
NOT USED
NOT USED
NOT USED
NOT USED
IF PAINTING ADJACENT WALLS PAINT HOLLOW METAL
STEEL DOORS, FRAMES, AND DOWNSPOUTS, EXPOSED
METAL FLASHING, HANDRAILS, AND EXPOSED
MISCELLANEOUS STEEL TO MATCH PRIMARY ADJACENT
BUILDING COLOR UNO
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
SHEET NOTES
OVERFLOW SCUPPER
WRAP PAINT AROUND THE BACKSIDE OF ALL CMU
COLUMNS & WALLS, ALL PORTRUDING ELEMENTS,
PILASTERS SIDES AND SOFFITS TYP AT ALL
ELEVATION UNO.
METAL FASCIA COVER
ISSUE BLOCK
1 PR#1 09/13/24
BM 996 ASHEN TAN
P83E
P215E
BM 1022 MAPLE SHADOWS
BM 1034 CLAYP124E
BM HC-72 BRANCHPORT BROWNP217E
ALL DETAILS WERE REVISED DUE TO
COLOR SCHEME DURING PR#1
•
THE FOLLOWING LEGEND HAS BEEN
REVISED DURING PR#1:
COLOR LEGEND
1
SCUPPER
(4" X 4")
EIFS CORNICE
11/26/24