Survey-Feedback185 NE 4TH AVE., SUITE 101
DELRAY BEACH, FL 33483
T: (561) 276-4951
F: (561) 243-8184
CURRIE SOWARDS
AGUILA ARCHITECTS
ARCHITECT
1615 FORUM PLACE, 3A
WEST PALM BEACH, FL 33401
T: (561) 622-8585
JEZERINAC GROUP
STRUCTURAL
902 CLINT MOORE ROAD, SUITE 142
BOCA RATON, FL 33487
T: (561) 900-2453
THOMPSON & YOUNGROSS
ENGINEERING CONSULTANTS
MEP
1400 CENTREPARK BOULEVARD, SUITE 905
WEST PALM BEACH, FL 33401
T: (561) 659-5760
CIVIL DESIGN, INC.
CIVIL
3604 PGA BOULEVARD, SUITE 220
PALM BEACH GARDENS, FL 33410
T: (561) 249-0940
INSITE STUDIO
LANDSCAPE / PLANNER
4201 WESTGATE AVENUE, SUITE A3
WEST PALM BEACH, FL 33409
T: (561) 625-8748
DEAN SURVEYING AND MAPPING, INC.
SURVEYOR
1425 ELLSWORTH INDUSTRIAL BOULEVARD, SUITE 10
ATLANTA, GA 30318
T: (404) 883-2474
LARSON NICHOLS, INTERIOR DESIGN
INTERIOR DESIGN
REVISIONS
DRAWING NUMBER
JOB NUMBER
DATE
DRAWING TITLE
DRAWN BY
CONSTRUCTION
SEAL
ISSUED FOR :
BIDS
PERMIT
PROJECT TITLE
THIS DOCUMENT IS THE PROPERTY OF CURRIE SOWARDS AGUILA ARCHITECTS INC. ALL RIGHTS ARE RESERVED. ANY POSSESSION, REPRODUCTION OR OTHER USE OF THIS DOCUMENT, WITHOUT THE WRITTEN CONSENT OF CURRIE SOWARDS AGUILA ARCHITECTS INC., IS PROHIBITED.Architecture, Planning,
Interiors, &
Sustainable Design
AA26001584
185 NE 4TH AVENUE SUITE 101
DELRAY BEACH, FL 33483
THESE DRAWINGS ARE PREPARED PER
ESTABLISHED INDUSTRY STANDARDS AND
REPRESENT THE ARCHITECT AND
ENGINEERS DESIGN CONCEPT. THEY ARE
NOT INTENDED TO PROVIDE EVERY
DETAIL OR CONDITION REQUIRED TO
CONSTRUCT THE BUILDING. THE
CONTRACTOR THROUGH SUBMITTALS
AND OTHER COORDINATION EFFORTS IS
FULLY RESPONSIBLE FOR PROVIDING A
COMPLETE AND OPERATIONAL BUILDING
WHETHER INDICATED ON THE PLANS OR
NOT.
T:(561) 276-4951 F:(561) 243-8184
E-MAIL: office@csa-architects.com
SPA
JESS M. SOWARDS
AR0013205
1/22/2026 1:30:16 PM1/22/2026 1:30:16 PMCOVER
KB / JF
A000
HUNTERS RUN
RACQUET SPORT
CENTER
3500 CLUBHOUSE LN.
BOYNTON BEACH, FL.
33436
220301.22
01/23/2026RESUBMITTAL #2FLEX SUB
01/23/2026DRC
HUNTERS RUN RACQUET SPORT
CENTER
BOYNTON BEACH, FL
ARCHITECTURE
Sheet Number Sheet Name
Current
Revision
A000COVER 2
A001GENERAL NOTES & PROJECT DATA
A100ARCHITECTURAL SITE PLAN 2
A201RAQUET SPORTS FLOOR PLAN 2
A202PROPOSED COMFORT STATION 2
A203TENNIS MAINTENANCE BUILDING PLANS 2
A204PICKLE BALL COVER STRUCTURE 2
A205TENNIS GRANDSTAND STRUCTURE 2
A301PRO SHOP BUILDING ELEVATIONS 2
A302PRO SHOP BUILDING ELEVATIONS 2
A305BUILDING COLOR ELEVATIONS 2
A306BUILDING COLOR ELEVATIONS 2
A307BUILDING COLOR ELEVATIONS
A308RACQUET CENTER SECTION/DETAIL 2
UPDATED COVER RENDERING
2
NUM.DESCRIPTION DATE
2 SPA REV. 2 1/21/2026
APPROVED
Planning & Zoning
sevignyr 03/06/2026
Room name
101
150 SF ROOM NAME, AREA, & NUMBER
DETAIL NUMBER
SHEET NUMBER
ELEVATION
DOOR & DOOR NUMBER
100
A101
1 Ref
1 Ref1 Ref
1 RefWALL TYPE
VIEW REFERENCE
100 DOOR NUMBER
STOREFRONT & WINDOW TYPE TAG
CENTERLINE
SECTION DETAIL NUMBER
SHEET NUMBER
CALLOUT AREA
SECTION DIRECTION OF VIEW
PROPERTYLINE
1
A
GRID BUBBLE NUMBERS HORIZONTALLY
GRID BUBBLE NUMBERS VERTICALLY
GRID LINE
REVISION CLOUD
REVISION DELTA SYMBOL
TRUE
NRECESS & RECESS DIMENSION
SLOPE DIRECTION
ELEVATION0'-0"
T.O. SLAB
PROJECT NORTH AND TRUE NORTH
01'2'16'4'8'
GRAPHIC SCALE
REFERENCE SYMBOLS
TYPE DESCRIPTIONTYPEDESCRIPTION
S1
A 1
A101
SIM
A101
1 SIM
/SEE SHEET----
1t
99'-99"CEILING TYPE AND HEIGHT TAG
1
HEIGHT:
BUILDING DATA
75' 37' - 10" (54.13' NAVD)
BUILDING SQUARE FOOTAGE
BUILDING TOTAL SQ. FT:13,765 SF
38,000 SF PER FLOOR
PER FBC TABLE 506.2
CODE MAX:PROPOSED:
OCCUPANCY CLASSIFICATIONS:
ASSEMBLY (A-2)
NUMBER OF STORIES 3 1
TYPE OF CONSTRUCTION:TYPE II-B (SPRINKLERED)
MAIN BUILDING:
11,893 SF (A-2)
MAIN BUILDING
(RAQUET SPORTS) (A-2)
COMFORT STATION:
772 SF (U)
COMFORT STATION (U)
TENNIS MAINTENANCE
BUILDING:
1,100 SF (S-1)
TENNIS MAINTENANCE
BUILDING (S-1)
34,000 SF PER FLOOR
PER FBC TABLE 506.2
70,000 SF PER FLOOR
PER FBC TABLE 506.2
ABBREVIATIONS
LEGAL DESCRIPTION
LEGAL DESCRIPTION :
TRACT 21, SUMMIT PLAT NO.1, ACCORDING TO THE PLAT THEREOF RECORDED IN PLAT
BOOK 36, AT PAGES 48 THROUGH 51, IN THE OFFICE OF THE CLERK OF THE CIRCUIT
COURT, IN AND FOR THE PALM BEACH COUNTY, FLORIDA.
APPLICABLE BUILDING CODES
FLORIDA BUILDING CODE 2023, 8TH EDITION
FLORIDA MECHANICAL CODE 2023, 8TH EDITION
FLORIDA PLUMBING CODE 2023, 8TH EDITION
FLORIDA EXISTING BUILDING CODE 2023, 8TH EDITION
FLORIDA ACCESSIBILITY CODE 2023, 8TH EDITION
NATIONAL ELECTRICAL CODE, FL EDITION 2020
FLORIDA FIRE PREVENTION CODE 2023, 8TH EDITION
GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
35.
36.
37.
38.
39.
THIS PROJECT IS TO BE CONSTRUCTED UNDER THE PROVISIONS OF THE FLORIDA BUILDING CODE FIFTH EDITION, FLORIDA
ACCESSIBILITY CODE 2014, NFPA 1 AND NFPA 101, ADA, FLORIDA STATE STATUTES AND ALL OTHER APPLICABLE CODES.
THE CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE HIMSELF WITH THE EXISTING CONDITIONS AND NOTIFY THE ARCHITECT OF
ANY OBSERVED DISCREPANCIES PRIOR TO SUBMISSION OF BIDS.
DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALE DIMENSIONS.
ANY WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED.
THESE DRAWINGS ARE DIAGRAMMATIC AND ARE INTENDED TO SHOW THE DESIGN INTENT ONLY. THEY DO NOT SHOW EVERY MINOR
DETAIL OF CONSTRUCTION. ALL TRADES ARE RESPONSIBLE FOR FURNISHING COMPLETE BUILDING SYSTEMS AND ALL ITEMS THAT
WOULD NORMALLY BE CONSIDERED INCIDENTAL TO THEIR INSTALLATION.
THE CONTRACTOR SHALL REVIEW THE PROJECT CONTRACT DOCUMENTS AND NOTIFY THE ARCHITECT OF ANY OBSERVED
DISCREPANCIES PRIOR TO START OF CONSTRUCTION.
ALL EXPOSED STUCCO, CEMENT, PLASTER OR GYPSUM BOARD SURFACES TO BE PAINTED UNLESS OTHERWISE NOTED. COLOR TO BE
SELECTED BY ARCHITECT. REFER TO SPECIFICATION FOR APPLICATION PROCEDURE.
ALL FIRE RATED WALLS AND PARTITIONS AND PARTITIONS INSULATED FOR SOUND TRANSMISSION ARE TO RUN CONTINUOUS FROM
FLOOR TO UNDERSIDE OF ROOF/FLOOR DECK ABOVE. ALL JOINTS TO BE TAPED AND SPACKLED AND ANY DUCT PENETRATIONS TO BE
FIRE DAMPERED AS REQUIRED BY CODE.
ALL CEMENT PLASTER OR PORTLAND CEMENT BOARD ABUTTING OTHER MATERIAL TO BE FINISHED WITH METAL EDGE STRIPS.
ALL ELECTRICAL CABINETS, FIRE EXTINGUISHERS, CABINETS AND OTHER RECESSED EQUIPMENT IN FIRE RATED WALLS SHALL BE
BACKED WITH 5/8" TYPE X GYPSUM BOARD OR AS REQUIRED TO MAINTAIN THE RATING.
PROVIDE DOUBLE STUDS OR WOOD BLOCKING AS REQUIRED TO SUPPORT WALL MOUNTED EQUIPMENT. BLOCKING IN CONTACT WITH
MASONRY/CONCRETE OR MOIST/HUMID CONDITIONS SHALL BE PRESSURE TREATED.
ALL EXPOSED METAL TO BE PAINTED. COLOR AS SELECTED BY THE ARCHITECT. REFER TO SPECIFICATION FOR APPLICATION
PROCEDURE.
NO ASBESTOS IN ANY FORM WILL BE PERMITTED IN THIS BUILDING.
ALL DIMENSIONS SHOWN ON THIS PLAN ARE NOMINAL. THE CONTRACTOR SHALL BE RESPONSIBLE TO ADJUST ACTUAL CONSTRUCTION
DIMENSIONS SLIGHTLY TO ALLOW FOR EXACT MATERIAL THICKNESS AND REQUIRED CLEARANCE. DIMENSIONS ON PLANS ARE TO
FINISH OF INTERIOR STUD PARTITIONS, CENTERLINE OF CONSTRUCTION LINES, AND FACE OF MASONRY.
THE STRUCTURAL DRAWINGS SHALL TAKE PRECEDENCE OVER ARCHITECTURAL DRAWINGS WITH RESPECT TO COLUMN AND
STRUCTURAL ELEMENTS LOCATIONS. CONTRACTOR SHALL NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPENCIES.
IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND EACH OF HIS SUBCONTRACTORS TO REVIEW ALL DRAWINGS, PROJECT
MANUAL ADDENDA ETC. TO ASSURE COORDINATION OF ALL WORK AFFECTING EACH TRADE. FAILURE TO REVIEW ALL CONTRACT
DOCUMENTS FOR APPLICABLE ITEMS OF WORK SHALL NOT RELIEVE THE RESPONSIBLE PARTY FROM PERFORMING WORK SO
REQUIRED. WORK SHOWN ON ONE DRAWING IS AS GOOD AS IF SHOWN ON EVERY DRAWING.
EXISTING CONDITIONS- THE EXISTING SITE DIMENSIONS AND CONDITIONS SHOWN ON THESE DRAWINGS ARE ASSUMED TO BE
ACCURATE BASED ON AVAILABLE INFORMATION. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS ON THE JOB SITE AND
NOTIFY THE ARCHITECT OF DEVIATIONS FROM THESE DRAWINGS.
N.I.C. ITEMS- ALL ITEMS MARKED N.I.C. (NOT IN CONTRACT) ARE TO BE FURNISHED BY THE OWNER. CONSULT THE ARCHITECT FOR ANY
ADDITIONAL REQUIRED INFORMATION NOT SHOWN.
DUCTS, PIPES, CONDUIT, ETC.- ALL VERTICAL AND HORIZONTAL DUCTS, PIPES, CONDUIT, ETC. (WHETHER SHOWN OR NOT) IN FINISHED
ROOMS SHALL BE LOCATED IN WALL. ITEMS THAT CANNOT BE LOCATED IN WALL SHALL BE FURRED IN AND FINISHED TO MATCH
ADJACENT FINISHED SURFACES AND ANY REQUIRED WALL OR CEILING RATINGS. VERIFY ACCEPTABILITY WITH ARCHITECT PRIOR TO
ENCASEMENT.
ACCESS PANELS: FURNISH AND INSTALL ACCESS PANELS, WHETHER SHOWN OR NOT, IN WALLS AND NON-ACCESSIBLE TYPE CEILINGS
WHERE SERVICE OR ADJUSTMENT TO MECHANICAL, FIRE PROTECTION, PLUMBING, OR ELECTRICAL EQUIPMENT IS REQUIRED.
FIXTURES, LAVATORIES AND SINKS SHALL BE INSTALLED A MINIMUM OF 4" FROM FINISHED SIDE WALLS. WATER CLOSETS SHALL BE
INSTALLED A MINIMUM OF 15" FROM FINISHED SIDE WALLS OR TOILET PARTITIONS TO CENTERLINE OF FIXTURE (18" TO CENTERLINE FOR
HANDICAP FIXTURES).
PRECAUTIONS: DO NOT PROCEED WITH WORK IF UNFORESEEN CONDITIONS ARE DISCOVERED WHICH COULD CAUSE ADVERSE
EFFECTS UPON THE STRUCTURE OR ITS OCCUPANTS. REPORT ANY SUCH CONDITION IMMEDIATELY TO THE ARCHITECT. TAKE
PRECAUTIONS TO PROPERLY SUPPORT THE STRUCTURE. THE CONTRACTOR SHALL REPORT ALL TOXIC MATERIALS LOCATED TO
OWNER, ARCHITECT AND AUTHORITIES HAVING JURISDICTION. REMOVAL OF MATERIAL WILL BE COMPLETED PER APPROVED MEANS
BEFORE CONSTRUCTION CONTINUES.
SAFETY: PROVIDE, ERECT AND MAINTAIN BARRICADES, LIGHTING AND GUARDRAILS AS REQUIRED BY APPLICABLE REGULATORY
AGENCIES TO PROTECT OCCUPANTS OF BUILDING AND WORKERS.
IF DISCREPANCIES EXIST BETWEEN SPECIFICATIONS AND DRAWINGS, THE MORE STRINGENT REQUIREMENT SHALL PREVAIL. NOTIFY
THE ARCHITECT OF ANY DISCREPANCIES TO OBTAIN CLARIFICATION.
EXIT ACCESS: MAINTAIN FREE, SAFE, AND APPROVED MEANS OF EGRESS IN AND OUT OF PROJECT LOCATION IN ACCORDANCE WITH
REQUIREMENTS OF APPLICABLE REGULATORY AGENCIES.
FINISHES: ALL FINISHES AND COLORS OF FIXTURES, EQUIPMENT, LIGHTS, DIFFUSERS, SINKS, PAINT, WALLCOVERINGS, ETC. SHALL BE
SELECTED BY ARCHITECT. SUBMIT FULL RANGE OF AVAILABLE FINISHES TO ARCHITECT FOR SELECTION. REFER TO FINISH SCHEDULE
AND NOTES.
STRUCTURAL REINFORCEMENT: IN THE EVENT THAT WINDOW OR STOREFRONT SIZES DICTATE THE NEED FOR ADDITIONAL
STRUCTURAL REINFORCEMENT, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE SUCH REINFORCEMENT
DESIGNED BY A REGISTERED ENGINEER AS PART OF THE WINDOW SYSTEM FOR NO ADDITIONAL COST.
PARTITIONS THAT ABUT THE STOREFRONT OR WINDOWS SHALL HAVE PAINTED ALUMINUM END CLOSURE.
THE GENERAL CONTRACTOR SHALL COORDINATE OPENINGS IN SLABS AND WALLS AS REQUIRED FOR THE INSTALLATION OF
MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION ITEMS. DO NOT CUT CONCRETE COLUMNS, BEAMS, OR OTHER
STRUCTURAL ELEMENT WITHOUT THE PRIOR WRITTEN PERMISSION OF THE STRUCTURAL ENGINEER OF RECORD.
SUPPLY AND RETURN REGISTERS IN CEILINGS SHALL BE INSTALLED OFFSET FROM ONE ANOTHER TO AVOID SOUND PASSAGE FROM
ONE ROOM TO ANOTHER. SOUND RATED ROOMS SHALL HAVE SOUND BOOTS INSTALLED IN THE DUCTWORK TO RESTRICT THE
PASSAGE OF SOUND.
CONTRACTOR SHALL HOLD A MEETING OF ALL SUB-CONTRACTORS WHO HAVE WORK THAT IS TO BE INSTALLED ABOVE THE CEILING
PRIOR TO THE START OF THEIR INSTALLATION FOR THE PURPOSE OF COORDINATING NECESSARY CLEARANCES AND PROPER
ROUTING. CONTRACTOR TO SUBMIT A TYPICAL SECTION DRAWN TO SCALE SHOWING THE ASSIGNED LAYERING.
CONTRACTOR SHALL CARRY BANDING, SCORE LINES, FINISHES ETC. AROUND EXTERIOR ARCHITECTURAL ELEMENTS SUCH AS
COLUMNS, ARCHES, SCREEN WALLS ETC. WHEN NO ELEVATION IS SHOWN FOR THOSE SIDE OR REAR ELEVATIONS.
WHERE A STUD WALL ABUTS A FURRED OUT MASONRY WALL THE CONTRACTOR SHALL HOLD THE FACE OF THE FURRING STRIP, SO
THAT A SMOOTH UNINTERRUPTED LAYER OF GYPSUM BOARD MAY BE APPLIED.
THE CONTRACTOR SHALL SELECT APPROPRIATE MATERIALS THAT ARE BEST SUITED FOR THEIR INTENDED USE.
THE GENERAL CONTRACTOR SHALL REVIEW WITH THE OWNER, ALL LIGHTING FIXTURES, PLUMBING FIXTURES AND DOOR HARDWARE
PRIOR TO ORDER PLACEMENT. IN THE EVENT THE OWNER IS NOT GIVEN THE OPPORTUNITY TO REVIEW AND APPROVE SAID FIXTURES,
THE ARCHITECT SHALL NOT BE HELD RESPONSIBLE FOR REPLACEMENT, RETURN OR RESTOCKING FEES ASSOCIATED WITH
CORRECTING THE ITEMS TO THE OWNER'S SATISFACTION.
ANY EXPOSED PLUMBING, ELECTRICAL OR FIRE SPRINKLER CONDUIT OR PIPING SHALL BE PAINTED TO MATCH ADJACENT SURFACES
UNLESS OTHERWISE NOTED.
WHEN STUCCO IS APPLIED TO A VERTICAL SURFACE, THE CONTRACTOR SHALL INSTALL STUCCO CONTROL JOINTS AS INDICATED IN THE
CONTRACT DOCUMENTS AND AS OTHERWISE NECESSARY ON A REGULAR GRID NOT EXCEEDING 140 SF, AS APPROVED BY THE
ARCHITECT.
WHEN STUCCO IS APPLIED TO A HORIZONTAL SURFACE, THE CONTRACTOR SHALL INSTALL STUCCO CONTROL JOINTS AS INDICATED IN
THE CONTRACT DOCUMENTS AND AS OTHERWISE NECESSARY ON A REGULAR GRID NOT EXCEEDING 100 SF, AS APPROVED BY THE
ARCHITECT.
THE ARCHITECTURAL DRAWINGS ARE PART OF THE CONTRACT DOCUMENTS AND DO NOT, BY THEMSELVES, PROVIDE ALL THE
INFORMATION REQUIRED TO PROPERLY CONSTRUCT THE PROJECT. THE GENERAL CONTRACTOR SHALL CONSULT THE STRUCTURAL,
MECHANICAL, ELECTRICAL, PLUMBING, FIRE PROTECTION, CIVIL, LANDSCAPING, AND SPECIALTY CONSULTANT'S DRAWINGS AND
COORDINATE THE INFORMATION CONTAINED IN THOSE DRAWINGS WITH THE ARCHITECTURAL DRAWINGS TO PROPERLY CONSTRUCT
THE PROJECT. REFER TO MECHANICAL, ELECTRICAL, PLUMBING AND STRUCTURAL FOR ADDITIONAL OPENINGS, DEPRESSIONS,
PENETRATIONS, INSERTS, DRAINS, ETC. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT, BEFORE
PROCEEDING WITH ANY WORK. THIS COORDINATION IS THE CONTRACTORS RESPONSIBILITY, AND NO EXTRA COMPENSATION WILL BE
ALLOWED RESULTING FROM THE CONTRACTORS FAILURE TO COMPLY WITH THESE REQUIREMENTS.
REVISIONS
DRAWING NUMBER
JOB NUMBER
DATE
DRAWING TITLE
DRAWN BY
CONSTRUCTION
SEAL
ISSUED FOR :
BIDS
PERMIT
PROJECT TITLE
THIS DOCUMENT IS THE PROPERTY OF CURRIE SOWARDS AGUILA ARCHITECTS INC. ALL RIGHTS ARE RESERVED. ANY POSSESSION, REPRODUCTION OR OTHER USE OF THIS DOCUMENT, WITHOUT THE WRITTEN CONSENT OF CURRIE SOWARDS AGUILA ARCHITECTS INC., IS PROHIBITED.Architecture, Planning,
Interiors, &
Sustainable Design
AA26001584
185 NE 4TH AVENUE SUITE 101
DELRAY BEACH, FL 33483
THESE DRAWINGS ARE PREPARED PER
ESTABLISHED INDUSTRY STANDARDS AND
REPRESENT THE ARCHITECT AND
ENGINEERS DESIGN CONCEPT. THEY ARE
NOT INTENDED TO PROVIDE EVERY
DETAIL OR CONDITION REQUIRED TO
CONSTRUCT THE BUILDING. THE
CONTRACTOR THROUGH SUBMITTALS
AND OTHER COORDINATION EFFORTS IS
FULLY RESPONSIBLE FOR PROVIDING A
COMPLETE AND OPERATIONAL BUILDING
WHETHER INDICATED ON THE PLANS OR
NOT.
T:(561) 276-4951 F:(561) 243-8184
E-MAIL: office@csa-architects.com
SPA
JESS M. SOWARDS
AR0013205
1/22/2026 1:30:17 PM1/22/2026 1:30:17 PMGENERAL NOTES
& PROJECT DATA
KB / JF
A001
HUNTERS RUN
RACQUET SPORT
CENTER
3500 CLUBHOUSE LN.
BOYNTON BEACH, FL.
33436
220301.22
01/23/2026RESUBMITTAL #2FLEX SUB
01/23/2026DRC
#NUMBER OR POUND
&AND
2:1 SL2 HORIZONTAL TO 1 VERTICAL
SLOPE
@AT
[CHANNEL
±PLUS MINUS
≤LESS THAN OR EQUAL TO
≥GREATER THAN OR EQUAL TO
ABANCHOR BOLT
ACAPSHALTIC CONCRETE
ACTACOUSTIC CEILING TILE
ADAREA DRAIN
ADJADJUSTABLE
AFFABOVE FINISH FLOOR
ALALUMINUM
ALTALTERNATE
ARCHARCHITECTURAL, ARCHITECT,
ARCHITECTURE
ASPHASPHALT
BBASELINE
BBOTTOM
BEJBRICK EXPANSION JOINT
BLDGBUILDING
BLKBLOCK
BMBEAM
BOBOARD, BOTTOM
BRGBEARING
BSMTBASEMENT
C&GCURB & GUTTER
CAPCAPACITY
CEMCEMENT
CGCORNER GUARD
CIPCAST IN PLACE, CAST IRON PIPE
CIRCIRCULATING
CJCONTROL JOINT
CLCENTERLINE
CLCENTERLINE
CLGCEILING
CLRCLEAR
CMUCONCRETE MASONRY UNITS
COLCOLUMN
CONCCONCRETE
CONNCONNECTION
CONSTCONSTRUCTION
CONTCONTINUOUS
CPTCARPET
CSKCOUNTERSUNK
CTCERAMIC TILE
CTRCENTER
DDEPTH
DETDETAIL
DFDRINKING FOUNTAIN
DIADIAMETER
DIMDIMENSION
DNDOWN
DSDOWNSPOUT
DWGDRAWING
EEAST
E/PEDGE OF PAVEMENT
EAEACH
ELELEVATION
ELECTELECTRICAL
ELEVELEVATOR
EMEREMERGENCY
EQEQUAL
EQUIPEQUIPMENT
EWEACH WAY
EWCELECTRIC WATER COOLER
EXISTEXISTING
EXPEXPANSION
EXP JTEXPANSION JOINT
EXTEXTERIOR
FD FLOOR DRAIN
FDN FOUNDATION
FE FIRE EXTINGUISHER
FFE FINISHED FLOOR ELEVATION
FH FIRE HYDRANT
FHC FIRE HOSE CABINET
FIN FINISH
FLR FLOOR
FR FRAME
FTG FOOTING
FXTR FIXTURE
G GROUND
GA GA
GALV GALVANIZED
GL GLASS
GR GRADE
GRD GROUND
GWB GYPSUM WALL BOARD
HB HOSE BIBB
HC HANDICAPPED
HDW HARDWARE
HGT HEIGHT
HORZ HORIZONTAL
HR HOUR
HW HOT WATER
ID INSIDE DIAMETER, INTERIOR
DESIGN
IE INVERT ELEVATION
INSUL INSULATION
INT INTERIOR
INTX INTERSECTION
INV INVERT
JB JUNCTION BOX
JCT JUNCTION
JST JOIST
JT JOINT
L ANGLE
L LENGTH
LC LENGTH OF CURVE
LDC LEAD COVERED
LL LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LT LIGHT
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MET METAL
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MTD MOUNTED
MTG MOUNTING
MULL MULLION
MWP MEMBRANE WATERPROOFING
N NORTH
NA NOT APPLICABLE
NE NORTHEAST
NEC NATIONAL ELECTRIC CODE
NEUT NEUTRAL
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
NW NIORTHWEST
OA OUTSIDE AIR
OA OUTSIDE AIR
OC ON CENTER
OFCI OWNER FURNISHED,
CONTRACTOR INSTALLED
OFOI OWNER FURNISHED, OWNER
INSTALLED
OPP OPPOSITE
OVHD OVERHEAD
PI POINT IF INTERSECTION
PL PLATE
PLAS PLASTER
PLYWD PLYWOOD
PNL PANEL
PNT PAINT
PRELIM PRELIMINARY
PRESS PRESSURE
PRIM PRIMARY
PRTN PARTITION
PT POINT, POINT OF TANGENT
QT QUARRY TILE
R RADIUS
RA RETURN AIR
RB RESILIENT VINYL BASE
RCP REINFORCED CONCRETE PIPE
RD ROOF DRAIN
RECP RECEPTACLE
REINF REINFORCEMENT
REQD REQUIRED
REV REVISION
RF ROOF
RFLCP REFLECTIVE CEILING PLAN
RM ROOM
RVT RESILIENT VINYL TILE
S SOUTH
SCH SCHEDULE
SD STORM DRAIN
SE SOUTHEAST
SECT SECTION
SHT SHEET
SIM SIMILIAR
SL SLOPE
SPEC SPECIFICATION
SQ SQUARE
STL STEEL
SUSP SUSPENDED
T TOP
T&B TOP AND BOTTOM
TEL TELEPHONE
TEMP TEMPORARY
TERM TERMINAL
THK THICK/THICKNESS
THRSLD THRESHOLD
TO TOP OF
TOS TOP OF STEEL, TOP OF SLAB
TOW TOP OF WALL
TYP TYPICAL
U.N.O UNLESS NOTED OTHERWISE
VCT VINYL COMPOSITION TILE
VENT VENTILIATING
VERT VERTICAL
VEST VESTIBULE
VWC VINYL WALL COVERING
W WIDTH, WEST
W/WITH
W/O WITHOUT
WC WATER CLOSET
WD WIDTH
WT WEIGHT
WWF WELDED WIRE FABRIC
X TRANSFORMER
NUM.DESCRIPTION DATE
APPROVED
Planning & Zoning
sevignyr 03/06/2026
F.E.(12) EXISTING PICKLEBALL COURTSTO REMAIN(3) EXISTING TENNISCOURTS TO REMAINGRANDSTANDS(3) NEW TENNISCOURTSTREE CANOPY
LINE
(14) NEW GOLF CARTS
PARKING SPACES
(30) NEW GOLF CARTS PARKING SPACES(4) BOCCE COURTS 12'x60' EA.RELOCATED
10' FPL UE 1260 SFCOVERED ARCADE(3) EXISTING TENNISCOURTS TO REMAIN(3) EXISTING TENNISCOURTS TO REMAIN(3) EXISTING TENNISCOURTS TO REMAINNEW TENNIS
TOURNAMENT
COURT
69'x120'1745 SFCOVERED PATIOREWORKED
PATHWAYSNEW ENTRY PATHWAYSNEW CANOPY, TYP.NEW CANOPY, TYP.NEW CANOPY, TYP.NEW CANOPY, TYP.740 SFSERVICE YARDNEW CART PATH
±11,893 SF
1-STORY
RAQUET SPORTS
& RESTAURANT 103 SEATSSEATING PLATFORMTEE BOXFPL.
TRANSFORMER
GRANDSTANDS97 SEATS2
2
COVERED PICKLEBALL TOURNAMENT COURTS±10,600 SF2
RELOCATED
10' FPL UE
2
2
REVISIONS
DRAWING NUMBER
JOB NUMBER
DATE
DRAWING TITLE
DRAWN BY
CONSTRUCTION
SEAL
ISSUED FOR :
BIDS
PERMIT
PROJECT TITLE
THIS DOCUMENT IS THE PROPERTY OF CURRIE SOWARDS AGUILA ARCHITECTS INC. ALL RIGHTS ARE RESERVED. ANY POSSESSION, REPRODUCTION OR OTHER USE OF THIS DOCUMENT, WITHOUT THE WRITTEN CONSENT OF CURRIE SOWARDS AGUILA ARCHITECTS INC., IS PROHIBITED.Architecture, Planning,
Interiors, &
Sustainable Design
AA26001584
185 NE 4TH AVENUE SUITE 101
DELRAY BEACH, FL 33483
THESE DRAWINGS ARE PREPARED PER
ESTABLISHED INDUSTRY STANDARDS AND
REPRESENT THE ARCHITECT AND
ENGINEERS DESIGN CONCEPT. THEY ARE
NOT INTENDED TO PROVIDE EVERY
DETAIL OR CONDITION REQUIRED TO
CONSTRUCT THE BUILDING. THE
CONTRACTOR THROUGH SUBMITTALS
AND OTHER COORDINATION EFFORTS IS
FULLY RESPONSIBLE FOR PROVIDING A
COMPLETE AND OPERATIONAL BUILDING
WHETHER INDICATED ON THE PLANS OR
NOT.
T:(561) 276-4951 F:(561) 243-8184
E-MAIL: office@csa-architects.com
SPA
JESS M. SOWARDS
AR0013205
1/22/2026 1:30:18 PM1/22/2026 1:30:18 PMARCHITECTURAL
SITE PLAN
KB / JF
A100
HUNTERS RUN
RACQUET SPORT
CENTER
3500 CLUBHOUSE LN.
BOYNTON BEACH, FL.
33436
220301.22
01/23/2026RESUBMITTAL #2FLEX SUB
01/23/2026DRC
1" = 30'-0"A100
1OVERALL SITE PLAN
NUM.DESCRIPTION DATE
2 SPA REV. 2 1/21/2026
APPROVED
Planning & Zoning
sevignyr 03/06/2026
FECFE
FE
FEC
FECFE-K
FE-K FE-K
FE
FE
10'-6" x 12-10'
15'-4" x 12'-10"
10' x 12'-10"
11' X 15'
9' X 13'
6' x 10'
15' x 11'11' x 9'10' x 9'
MAIN
KITCHEN
HOSTESS
LINE OF ROOF
OVERHANG
FPL TRANSFORMER
OFFICEOFFICE
OFFICEIT CLOSET
FOOD &
BEVERAGE
CONFERENCE
ROOMCOPY/
KITCHENETTE
STRINGING
STORAGE
DRESS
ADA DRESS
RACQUET
CENTER
PRO-SHOP
WOMENS RR.MENS RRMENSLOCKERSWOMENSLOCKERSMENS
SHOWER
WOMENS
SHOWER
BAR
LOBBY
PIZZA
PREP/COOK
BAR DININGMAIN DINING CARD ROOM
SERVICE
YARD
REVISIONS
DRAWING NUMBER
JOB NUMBER
DATE
DRAWING TITLE
DRAWN BY
CONSTRUCTION
SEAL
ISSUED FOR :
BIDS
PERMIT
PROJECT TITLE
THIS DOCUMENT IS THE PROPERTY OF CURRIE SOWARDS AGUILA ARCHITECTS INC. ALL RIGHTS ARE RESERVED. ANY POSSESSION, REPRODUCTION OR OTHER USE OF THIS DOCUMENT, WITHOUT THE WRITTEN CONSENT OF CURRIE SOWARDS AGUILA ARCHITECTS INC., IS PROHIBITED.Architecture, Planning,
Interiors, &
Sustainable Design
AA26001584
185 NE 4TH AVENUE SUITE 101
DELRAY BEACH, FL 33483
THESE DRAWINGS ARE PREPARED PER
ESTABLISHED INDUSTRY STANDARDS AND
REPRESENT THE ARCHITECT AND
ENGINEERS DESIGN CONCEPT. THEY ARE
NOT INTENDED TO PROVIDE EVERY
DETAIL OR CONDITION REQUIRED TO
CONSTRUCT THE BUILDING. THE
CONTRACTOR THROUGH SUBMITTALS
AND OTHER COORDINATION EFFORTS IS
FULLY RESPONSIBLE FOR PROVIDING A
COMPLETE AND OPERATIONAL BUILDING
WHETHER INDICATED ON THE PLANS OR
NOT.
T:(561) 276-4951 F:(561) 243-8184
E-MAIL: office@csa-architects.com
SPA
JESS M. SOWARDS
AR0013205
1/22/2026 1:30:21 PM1/22/2026 1:30:21 PMRAQUET SPORTS
FLOOR PLAN
KB / JF
A201
HUNTERS RUN
RACQUET SPORT
CENTER
3500 CLUBHOUSE LN.
BOYNTON BEACH, FL.
33436
220301.22RESUBMITTAL #2FLEX SUB
01/23/202605/20/21
DRC
1/8" = 1'-0"A201
1RACQUET SPORTS FLOOR PLAN
2
NUM.DESCRIPTION DATE
2 SPA REV. 2 1/21/2026
APPROVED
Planning & Zoning
sevignyr 03/06/2026
F.E.
DRINK
STATION
WOMENS
RESTROOM
MENS
RESTROOM
18 SF
STORAGE
225 SF
247 SF250 SF38'-8"22'-8"
5" / 12"
5" / 12"5" / 12"5" / 12"O.H.
3'-0"
O.H.
3'-0"O.H.3'-0"O.H.3'-0"5"
12"5"
12"
STANDING SEAM METAL
ROOFING SYSTEM
L.G. MISSILE IMPACT
RESISTANT STOREFRONT
SMOOTH STUCCO
WATER TABLE TRIM
6'-0"0' - 0"
13' - 0"
18' - 8"
ROOF RIDGE
T.O. TIE BEAM
LEVEL 1
A/C CONDENSING UNIT
5"
12"
5"
12"8'-2"2'-2"STANDING SEAM METAL
ROOFING SYSTEM
L.G. MISSILE IMPACT
RESISTANT STOREFRONT
SMOOTH STUCCO
WATER TABLE TRIM
0' - 0"
13' - 0"
18' - 8"
ROOF RIDGE
T.O. TIE BEAM
LEVEL 1
STANDING SEAM METAL
ROOFING SYSTEM
SMOOTH STUCCO ON
CMU WALL
SMOOTH STUCCO
WATER TABLE TRIM
0' - 0"
ROOF RIDGE
T.O. TIE BEAM
LEVEL 1
13' - 0"
18' - 8"
ELECTRICAL SERVICES
STANDING SEAM METAL
ROOFING SYSTEM
L.G. MISSILE IMPACT
RESISTANT STOREFRONT
SMOOTH STUCCO
WATER TABLE TRIM
SMOOTH STUCCO ON
CMU WALL
ROOF RIDGE
T.O. TIE BEAM
LEVEL 1
0' - 0"
13' - 0"
18' - 8"8'-0"DECORATIVE WALL SCONCE
LIGHT FIXTURE
REVISIONS
DRAWING NUMBER
JOB NUMBER
DATE
DRAWING TITLE
DRAWN BY
CONSTRUCTION
SEAL
ISSUED FOR :
BIDS
PERMIT
PROJECT TITLE
THIS DOCUMENT IS THE PROPERTY OF CURRIE SOWARDS AGUILA ARCHITECTS INC. ALL RIGHTS ARE RESERVED. ANY POSSESSION, REPRODUCTION OR OTHER USE OF THIS DOCUMENT, WITHOUT THE WRITTEN CONSENT OF CURRIE SOWARDS AGUILA ARCHITECTS INC., IS PROHIBITED.Architecture, Planning,
Interiors, &
Sustainable Design
AA26001584
185 NE 4TH AVENUE SUITE 101
DELRAY BEACH, FL 33483
THESE DRAWINGS ARE PREPARED PER
ESTABLISHED INDUSTRY STANDARDS AND
REPRESENT THE ARCHITECT AND
ENGINEERS DESIGN CONCEPT. THEY ARE
NOT INTENDED TO PROVIDE EVERY
DETAIL OR CONDITION REQUIRED TO
CONSTRUCT THE BUILDING. THE
CONTRACTOR THROUGH SUBMITTALS
AND OTHER COORDINATION EFFORTS IS
FULLY RESPONSIBLE FOR PROVIDING A
COMPLETE AND OPERATIONAL BUILDING
WHETHER INDICATED ON THE PLANS OR
NOT.
T:(561) 276-4951 F:(561) 243-8184
E-MAIL: office@csa-architects.com
SPA
JESS M. SOWARDS
AR0013205
1/22/2026 1:30:22 PM1/22/2026 1:30:22 PMPROPOSED
COMFORT
STATION
KB / JF
A202
HUNTERS RUN
RACQUET SPORT
CENTER
3500 CLUBHOUSE LN.
BOYNTON BEACH, FL.
33436
220301.22RESUBMITTAL #2FLEX SUB
01/23/202606/09/25
DRC
3/16" = 1'-0"A202
1 COMFORT STATION FLOOR PLAN
3/16" = 1'-0"A202
2 COMFORT STATION ROOF PLAN
772 S.F.
3/16" = 1'-0"A202
3COMFORT STATION - NORTH ELEVATION - (RIGH SIDE)
3/16" = 1'-0"A202
4COMFORT STATION - SOUTH ELEVATION (LEFT SIDE)
3/16" = 1'-0"A202
5COMFORT STATION - WEST ELEVATION (REAR)
3/16" = 1'-0"A202
6COMFORT STATION - EAST ELEVATION
2
2
2
2
22
NUM.DESCRIPTION DATE
2 SPA REV. 2 1/21/2026
APPROVED
Planning & Zoning
sevignyr 03/06/2026
REF.FEFEFENEW
MAINTENANCE
BUILDING
50'-0"22'-0"
KITCHENETTE
JANITOR
ADA
RESTROOM
835 SF
103 SF
18 SF
46 SF
4" / 12"4" / 12"COVERED AREA12' - 8"FENCE AROUND
EXTERIOR PAD
STANDING SEAM METAL
ROOFING SYSTEM
LEVEL 1
T.O. TIE BEAM
IMPACT RESISTANT
COILING OVERHEAD DOOR
8' - 6"
W-SHAPE COLUMN
FOR ROOF
-1' - 6"
12' - 11"
ROOF RIDGE
4"
12"
4"
12"
STANDING SEAM METAL
ROOFING SYSTEM
LEVEL 1
T.O. TIE BEAM
0' - 0"
W-SHAPE COLUMN
FOR ROOF
ROOF RIDGE
14' - 5"
10' - 0"
FENCE AROUND
EXTERIOR PAD
METAL WALL PANEL
STANDING SEAM METAL
ROOFING SYSTEM
LEVEL 1
T.O. TIE BEAM
L.G. MISSILE IMPACT
RESISTANT STOREFRONT
10' - 0"
0' - 0"
14' - 5"
ROOF RIDGE
4"
12"
4"
12"
METAL WALL PANEL
8'-0"IMPACT RESISTANT
COILING OVERHEAD DOOR
IMPACT RESISTANT
METAL DOOR
STANDING SEAM METAL
ROOFING SYSTEM
10' - 0"
0' - 0"
LEVEL 1
T.O. TIE BEAM
ROOF RIDGE
14' - 5"7'-0"FENCE AROUND
EXTERIOR PAD
METAL WALL PANEL
REVISIONS
DRAWING NUMBER
JOB NUMBER
DATE
DRAWING TITLE
DRAWN BY
CONSTRUCTION
SEAL
ISSUED FOR :
BIDS
PERMIT
PROJECT TITLE
THIS DOCUMENT IS THE PROPERTY OF CURRIE SOWARDS AGUILA ARCHITECTS INC. ALL RIGHTS ARE RESERVED. ANY POSSESSION, REPRODUCTION OR OTHER USE OF THIS DOCUMENT, WITHOUT THE WRITTEN CONSENT OF CURRIE SOWARDS AGUILA ARCHITECTS INC., IS PROHIBITED.Architecture, Planning,
Interiors, &
Sustainable Design
AA26001584
185 NE 4TH AVENUE SUITE 101
DELRAY BEACH, FL 33483
THESE DRAWINGS ARE PREPARED PER
ESTABLISHED INDUSTRY STANDARDS AND
REPRESENT THE ARCHITECT AND
ENGINEERS DESIGN CONCEPT. THEY ARE
NOT INTENDED TO PROVIDE EVERY
DETAIL OR CONDITION REQUIRED TO
CONSTRUCT THE BUILDING. THE
CONTRACTOR THROUGH SUBMITTALS
AND OTHER COORDINATION EFFORTS IS
FULLY RESPONSIBLE FOR PROVIDING A
COMPLETE AND OPERATIONAL BUILDING
WHETHER INDICATED ON THE PLANS OR
NOT.
T:(561) 276-4951 F:(561) 243-8184
E-MAIL: office@csa-architects.com
SPA
JESS M. SOWARDS
AR0013205
1/22/2026 1:30:27 PM1/22/2026 1:30:27 PMTENNIS
MAINTENANCE
BUILDING PLANS
KB / JF
A203
HUNTERS RUN
RACQUET SPORT
CENTER
3500 CLUBHOUSE LN.
BOYNTON BEACH, FL.
33436
220301.22
01/23/2026RESUBMITTAL #2FLEX SUB
01/23/2026DRC
3/16" = 1'-0"A203
1 TENNIS MAINTENANCE FLOOR PLAN
1,100 S.F. 3/16" = 1'-0"A203
2 TENNIS MAINTENANCE ROOF PLAN
3/16" = 1'-0"A203
3MAINTENANCE BUILDING - EAST ELEVATION (RIGHT SIDE)
3/16" = 1'-0"A203
4MAINTENANCE BUILDING - NORTH ELEVATION (REAR)
3/16" = 1'-0"A203
5MAINTENANCE BUILDING - WEST ELEVATION (LEFT SIDE)
3/16" = 1'-0"A203
6MAINTENANCE BUILDING - SOUTH ELEVATION (FRONT)
FLIPPED BUILDING LAYOUT
1
NUM.DESCRIPTION DATE
1 ADA / FPL 9/3/2025
2 SPA REV. 2 1/21/2026
2
2
2
APPROVED
Planning & Zoning
sevignyr 03/06/2026
6
A204
RAMP UPRAMP UP1
2
3
4
5
6
7
8
9
10
11
AB
RAMP
UP
RAMP
UP18' - 0"ROOF HIGH POINT
28' - 7"27'-2"Level 10' - 0"
REVISIONS
DRAWING NUMBER
JOB NUMBER
DATE
DRAWING TITLE
DRAWN BY
CONSTRUCTION
SEAL
ISSUED FOR :
BIDS
PERMIT
PROJECT TITLE
THIS DOCUMENT IS THE PROPERTY OF CURRIE SOWARDS AGUILA ARCHITECTS INC. ALL RIGHTS ARE RESERVED. ANY POSSESSION, REPRODUCTION OR OTHER USE OF THIS DOCUMENT, WITHOUT THE WRITTEN CONSENT OF CURRIE SOWARDS AGUILA ARCHITECTS INC., IS PROHIBITED.Architecture, Planning,
Interiors, &
Sustainable Design
AA26001584
185 NE 4TH AVENUE SUITE 101
DELRAY BEACH, FL 33483
THESE DRAWINGS ARE PREPARED PER
ESTABLISHED INDUSTRY STANDARDS AND
REPRESENT THE ARCHITECT AND
ENGINEERS DESIGN CONCEPT. THEY ARE
NOT INTENDED TO PROVIDE EVERY
DETAIL OR CONDITION REQUIRED TO
CONSTRUCT THE BUILDING. THE
CONTRACTOR THROUGH SUBMITTALS
AND OTHER COORDINATION EFFORTS IS
FULLY RESPONSIBLE FOR PROVIDING A
COMPLETE AND OPERATIONAL BUILDING
WHETHER INDICATED ON THE PLANS OR
NOT.
T:(561) 276-4951 F:(561) 243-8184
E-MAIL: office@csa-architects.com
SPA
JESS M. SOWARDS
AR0013205
1/22/2026 1:30:39 PM1/22/2026 1:30:39 PMPICKLE BALL
COVER
STRUCTURE
KB / JF
A204
HUNTERS RUN
RACQUET SPORT
CENTER
3500 CLUBHOUSE LN.
BOYNTON BEACH, FL.
33436
220301.22
01/23/2026RESUBMITTAL #2FLEX SUB
01/23/2026DRC
1" = 10'-0"A204
1COVERED PICKLEBALL STRUCTURE
1/8" = 1'-0"A204
6PICKLEBALL STRUCTURE SECTION PICKLEBALL COVER STRUCTURE 3D VIEW
1" = 10'-0"A204
2COVERED PICKLEBALL - SOUTH ELEVATION
1" = 10'-0"A204
3COVERED PICKLEBALL - WEST ELEVATION
1" = 10'-0"A204
4 COVERED PICKLEBALL - EAST ELEVATION
1" = 10'-0"A204
5COVERED PICKLEBALL - NORTH ELEVATION
2
REVISED LAYOUT OF PICKLEBALL COURTS
REMOVED SIDE WALLS & CANOPIES
2
2
2
NUM.DESCRIPTION DATE
2 SPA REV. 2 1/21/2026
APPROVED
Planning & Zoning
sevignyr 03/06/2026
7
A205
RAMP UPRAMP UP7
A205
PRE-ENGINEER MTL
ROOF SYSTEM
5'-0 1/2"1'-4"13' - 5 1/2"PRE-ENGINEER MTL
ROOF SYSTEM
ACCORDION STYLE DOORS
FOR STORAGE SPACE, TYP.
REVISIONS
DRAWING NUMBER
JOB NUMBER
DATE
DRAWING TITLE
DRAWN BY
CONSTRUCTION
SEAL
ISSUED FOR :
BIDS
PERMIT
PROJECT TITLE
THIS DOCUMENT IS THE PROPERTY OF CURRIE SOWARDS AGUILA ARCHITECTS INC. ALL RIGHTS ARE RESERVED. ANY POSSESSION, REPRODUCTION OR OTHER USE OF THIS DOCUMENT, WITHOUT THE WRITTEN CONSENT OF CURRIE SOWARDS AGUILA ARCHITECTS INC., IS PROHIBITED.Architecture, Planning,
Interiors, &
Sustainable Design
AA26001584
185 NE 4TH AVENUE SUITE 101
DELRAY BEACH, FL 33483
THESE DRAWINGS ARE PREPARED PER
ESTABLISHED INDUSTRY STANDARDS AND
REPRESENT THE ARCHITECT AND
ENGINEERS DESIGN CONCEPT. THEY ARE
NOT INTENDED TO PROVIDE EVERY
DETAIL OR CONDITION REQUIRED TO
CONSTRUCT THE BUILDING. THE
CONTRACTOR THROUGH SUBMITTALS
AND OTHER COORDINATION EFFORTS IS
FULLY RESPONSIBLE FOR PROVIDING A
COMPLETE AND OPERATIONAL BUILDING
WHETHER INDICATED ON THE PLANS OR
NOT.
T:(561) 276-4951 F:(561) 243-8184
E-MAIL: office@csa-architects.com
SPA
JESS M. SOWARDS
AR0013205
1/22/2026 1:30:45 PM1/22/2026 1:30:45 PMTENNIS
GRANDSTAND
STRUCTURE
KB / JF
A205
HUNTERS RUN
RACQUET SPORT
CENTER
3500 CLUBHOUSE LN.
BOYNTON BEACH, FL.
33436
220301.22
01/23/2026RESUBMITTAL #2FLEX SUB
01/23/2026DRC
1/8" = 1'-0"A205
1 GRAND STANDS - SEATING PLAN
1/8" = 1'-0"A205
2 GRAND STANDS - ROOF PLAN
1/8" = 1'-0"A205
7GRANDSTAND SECTION
1/8" = 1'-0"A205
3GRANDSTAND - SOUTH ELEVATION 1/8" = 1'-0"A205
4GRANDSTAND - NORTH ELEVATION
1/8" = 1'-0"A205
5 GRANDSTAND - EAST ELEVATION
1/8" = 1'-0"A205
6 GRANDSTAND - WEST ELEVATION
2
2
2
NUM.DESCRIPTION DATE
2 SPA REV. 2 1/21/2026
APPROVED
Planning & Zoning
sevignyr 03/06/2026
H.P. OF ROOF
Level 1
0' - 0"
14' - 0"
T.O. TIE BEAM
38' - 10 21/32"
4"
12"
4"
12"
T.O. MECH. WELL
29' - 0"
38' - 10 21/32"
14' - 0"
0' - 0"
H.P. OF ROOF
T.O. MECH. WELL
T.O. TIE BEAM
LEVEL 1
29' - 0"
REVISIONS
DRAWING NUMBER
JOB NUMBER
DATE
DRAWING TITLE
DRAWN BY
CONSTRUCTION
SEAL
ISSUED FOR :
BIDS
PERMIT
PROJECT TITLE
THIS DOCUMENT IS THE PROPERTY OF CURRIE SOWARDS AGUILA ARCHITECTS INC. ALL RIGHTS ARE RESERVED. ANY POSSESSION, REPRODUCTION OR OTHER USE OF THIS DOCUMENT, WITHOUT THE WRITTEN CONSENT OF CURRIE SOWARDS AGUILA ARCHITECTS INC., IS PROHIBITED.Architecture, Planning,
Interiors, &
Sustainable Design
AA26001584
185 NE 4TH AVENUE SUITE 101
DELRAY BEACH, FL 33483
THESE DRAWINGS ARE PREPARED PER
ESTABLISHED INDUSTRY STANDARDS AND
REPRESENT THE ARCHITECT AND
ENGINEERS DESIGN CONCEPT. THEY ARE
NOT INTENDED TO PROVIDE EVERY
DETAIL OR CONDITION REQUIRED TO
CONSTRUCT THE BUILDING. THE
CONTRACTOR THROUGH SUBMITTALS
AND OTHER COORDINATION EFFORTS IS
FULLY RESPONSIBLE FOR PROVIDING A
COMPLETE AND OPERATIONAL BUILDING
WHETHER INDICATED ON THE PLANS OR
NOT.
T:(561) 276-4951 F:(561) 243-8184
E-MAIL: office@csa-architects.com
SPA
JESS M. SOWARDS
AR0013205
1/22/2026 1:30:52 PM1/22/2026 1:30:52 PMPRO SHOP
BUILDING
ELEVATIONS
KB / JF
A301
HUNTERS RUN
RACQUET SPORT
CENTER
3500 CLUBHOUSE LN.
BOYNTON BEACH, FL.
33436
220301.22
01/23/2026RESUBMITTAL #2FLEX SUB
01/23/2026DRC
1" = 10'-0"A301
2EXTERIOR ELEVATION - WEST (FRONT)
2
2
1" = 10'-0"A301
1EXTERIOR ELEVATION - EAST (BACK)
2
22
2
NUM.DESCRIPTION DATE
1 ADA / FPL 9/3/2025
2 SPA REV. 2 1/21/2026
APPROVED
Planning & Zoning
sevignyr 03/06/2026
H.P. OF ROOF
14' - 0"
38' - 10 21/32"
T.O. TIE BEAM
T.O. MECH. WELL
0' - 0"
LEVEL 1
29' - 0"
H.P. OF ROOF
38' - 10 21/32"
14' - 0"
T.O. TIE BEAM
0' - 0"
LEVEL 1
T.O. MECH. WELL
29' - 0"
REVISIONS
DRAWING NUMBER
JOB NUMBER
DATE
DRAWING TITLE
DRAWN BY
CONSTRUCTION
SEAL
ISSUED FOR :
BIDS
PERMIT
PROJECT TITLE
THIS DOCUMENT IS THE PROPERTY OF CURRIE SOWARDS AGUILA ARCHITECTS INC. ALL RIGHTS ARE RESERVED. ANY POSSESSION, REPRODUCTION OR OTHER USE OF THIS DOCUMENT, WITHOUT THE WRITTEN CONSENT OF CURRIE SOWARDS AGUILA ARCHITECTS INC., IS PROHIBITED.Architecture, Planning,
Interiors, &
Sustainable Design
AA26001584
185 NE 4TH AVENUE SUITE 101
DELRAY BEACH, FL 33483
THESE DRAWINGS ARE PREPARED PER
ESTABLISHED INDUSTRY STANDARDS AND
REPRESENT THE ARCHITECT AND
ENGINEERS DESIGN CONCEPT. THEY ARE
NOT INTENDED TO PROVIDE EVERY
DETAIL OR CONDITION REQUIRED TO
CONSTRUCT THE BUILDING. THE
CONTRACTOR THROUGH SUBMITTALS
AND OTHER COORDINATION EFFORTS IS
FULLY RESPONSIBLE FOR PROVIDING A
COMPLETE AND OPERATIONAL BUILDING
WHETHER INDICATED ON THE PLANS OR
NOT.
T:(561) 276-4951 F:(561) 243-8184
E-MAIL: office@csa-architects.com
SPA
JESS M. SOWARDS
AR0013205
1/22/2026 1:30:59 PM1/22/2026 1:30:59 PMPRO SHOP
BUILDING
ELEVATIONS
KB / JF
A302
HUNTERS RUN
RACQUET SPORT
CENTER
3500 CLUBHOUSE LN.
BOYNTON BEACH, FL.
33436
220301.22
01/23/2026RESUBMITTAL #2FLEX SUB
01/23/2026DRC
1/8" = 1'-0"A302
1EXTERIOR ELEVATION - NORTH
1/8" = 1'-0"A302
2EXTERIOR ELEVATION - SOUTH
2
2
2
2
2 2
NUM.DESCRIPTION DATE
2 SPA REV. 2 1/21/2026
APPROVED
Planning & Zoning
sevignyr 03/06/2026
STOREFRONT NOTES
1. ALL EXTERIOR GLAZING SHALL BE LARGE MISSILE IMPACT RATED LAMINATED
GLASS BY VIRACON OR APPROVED EQUAL.
2. STOREFRONT FRAMES SHALL BE DARK BRONZE BY YKK OR APPROVED EQUAL.
3. GLASS SHALL BE 9/16" GRAY LAMINATED GLASS (1/4"/PVB/1/4"). VALUES AS
FOLLOWS:
U-VALUE: 0.93 WINTER NIGHT / 0.85 SUMMER DAY
SHGC: 0.50
VLT: 42 / REFLECTANCE 5%
MATERIAL LEGEND
COLOR MARK DESCRIPTION
PT-1
PT-2
MT-1
SMOOTH STUCCO PAINTED
SW 7006 - EXTRA WHITE
SMOOTH STUCCO PAINTED
SW 7659 - GRIS
STOREFRONTS, DOORS & GUTTERS
DARK BRONZE
MT-2 DREXEL METALS - ALUMINUM STANDING
SEAM ROOF - CHARCOAL FINISH
MT-3 STEEL PAINTED
SW 7659 - GRIS
MT-4 METAL DOOR & WALL PANEL PAINTED
SW 7006 - EXTRA WHITE
MT-2MT-2
PT-1PT-2PT-1 PT-2PT-2 PT-2PT-2PT-2PT-1PT-1 MT-1 PT-2 PT-1
PT-1
MT-1
PT-2
MT-2MT-2
PT-2PT-2PT-2PT-1PT-1 MT-1
PT-1 PT-2
PT-2
MT-2MT-2
PT-2
PT-1
MT-1 MT-2
PT-1PT-1PT-1PT-2PT-2 PT-1MT-1PT-2PT-2PT-2PT-1PT-1PT-1PT-1PT-1PT-1PT-2PT-2PT-2
PT-1PT-2
PT-2
MT-1
REVISIONS
DRAWING NUMBER
JOB NUMBER
DATE
DRAWING TITLE
DRAWN BY
CONSTRUCTION
SEAL
ISSUED FOR :
BIDS
PERMIT
PROJECT TITLE
THIS DOCUMENT IS THE PROPERTY OF CURRIE SOWARDS AGUILA ARCHITECTS INC. ALL RIGHTS ARE RESERVED. ANY POSSESSION, REPRODUCTION OR OTHER USE OF THIS DOCUMENT, WITHOUT THE WRITTEN CONSENT OF CURRIE SOWARDS AGUILA ARCHITECTS INC., IS PROHIBITED.Architecture, Planning,
Interiors, &
Sustainable Design
AA26001584
185 NE 4TH AVENUE SUITE 101
DELRAY BEACH, FL 33483
THESE DRAWINGS ARE PREPARED PER
ESTABLISHED INDUSTRY STANDARDS AND
REPRESENT THE ARCHITECT AND
ENGINEERS DESIGN CONCEPT. THEY ARE
NOT INTENDED TO PROVIDE EVERY
DETAIL OR CONDITION REQUIRED TO
CONSTRUCT THE BUILDING. THE
CONTRACTOR THROUGH SUBMITTALS
AND OTHER COORDINATION EFFORTS IS
FULLY RESPONSIBLE FOR PROVIDING A
COMPLETE AND OPERATIONAL BUILDING
WHETHER INDICATED ON THE PLANS OR
NOT.
T:(561) 276-4951 F:(561) 243-8184
E-MAIL: office@csa-architects.com
SPA
JESS M. SOWARDS
AR0013205
1/22/2026 1:31:08 PM1/22/2026 1:31:08 PMBUILDING COLOR
ELEVATIONS
KB / JF
A305
HUNTERS RUN
RACQUET SPORT
CENTER
3500 CLUBHOUSE LN.
BOYNTON BEACH, FL.
33436
220301.22
01/23/2026RESUBMITTAL #2FLEX SUB
01/23/2026DRC
1" = 10'-0"A305
1COLOR EXTERIOR ELEVATION - WEST (FRONT)
1" = 10'-0"A305
2COLOR EXTERIOR ELEVATION - EAST (BACK)
2
2
NUM.DESCRIPTION DATE
2 SPA REV. 2 1/21/2026
APPROVED
Planning & Zoning
sevignyr 03/06/2026
STOREFRONT NOTES
1. ALL EXTERIOR GLAZING SHALL BE LARGE MISSILE IMPACT RATED LAMINATED
GLASS BY VIRACON OR APPROVED EQUAL.
2. STOREFRONT FRAMES SHALL BE DARK BRONZE BY YKK OR APPROVED EQUAL.
3. GLASS SHALL BE 9/16" GRAY LAMINATED GLASS (1/4"/PVB/1/4"). VALUES AS
FOLLOWS:
U-VALUE: 0.93 WINTER NIGHT / 0.85 SUMMER DAY
SHGC: 0.50
VLT: 42 / REFLECTANCE 5%
MATERIAL LEGEND
COLOR MARK DESCRIPTION
PT-1
PT-2
MT-1
SMOOTH STUCCO PAINTED
SW 7006 - EXTRA WHITE
SMOOTH STUCCO PAINTED
SW 7659 - GRIS
STOREFRONTS, DOORS & GUTTERS
DARK BRONZE
MT-2 DREXEL METALS - ALUMINUM STANDING
SEAM ROOF - CHARCOAL FINISH
MT-3 STEEL PAINTED
SW 7659 - GRIS
MT-4 METAL DOOR & WALL PANEL PAINTED
SW 7006 - EXTRA WHITE
MT-2MT-2
PT-2
MT-1
PT-1
MT-2
PT-2PT-2PT-2PT-2
PT-1PT-1MT-1PT-2PT-2PT-1PT-1PT-1 PT-1 PT-2
PT-1
PT-2
MT-2
PT-1
MT-1
PT-2
MT-2MT-2
PT-1PT-1PT-1PT-2PT-2PT-2PT-2MT-1PT-1
PT-1
PT-2
REVISIONS
DRAWING NUMBER
JOB NUMBER
DATE
DRAWING TITLE
DRAWN BY
CONSTRUCTION
SEAL
ISSUED FOR :
BIDS
PERMIT
PROJECT TITLE
THIS DOCUMENT IS THE PROPERTY OF CURRIE SOWARDS AGUILA ARCHITECTS INC. ALL RIGHTS ARE RESERVED. ANY POSSESSION, REPRODUCTION OR OTHER USE OF THIS DOCUMENT, WITHOUT THE WRITTEN CONSENT OF CURRIE SOWARDS AGUILA ARCHITECTS INC., IS PROHIBITED.Architecture, Planning,
Interiors, &
Sustainable Design
AA26001584
185 NE 4TH AVENUE SUITE 101
DELRAY BEACH, FL 33483
THESE DRAWINGS ARE PREPARED PER
ESTABLISHED INDUSTRY STANDARDS AND
REPRESENT THE ARCHITECT AND
ENGINEERS DESIGN CONCEPT. THEY ARE
NOT INTENDED TO PROVIDE EVERY
DETAIL OR CONDITION REQUIRED TO
CONSTRUCT THE BUILDING. THE
CONTRACTOR THROUGH SUBMITTALS
AND OTHER COORDINATION EFFORTS IS
FULLY RESPONSIBLE FOR PROVIDING A
COMPLETE AND OPERATIONAL BUILDING
WHETHER INDICATED ON THE PLANS OR
NOT.
T:(561) 276-4951 F:(561) 243-8184
E-MAIL: office@csa-architects.com
SPA
JESS M. SOWARDS
AR0013205
1/22/2026 1:31:16 PM1/22/2026 1:31:16 PMBUILDING COLOR
ELEVATIONS
KB / JF
A306
HUNTERS RUN
RACQUET SPORT
CENTER
3500 CLUBHOUSE LN.
BOYNTON BEACH, FL.
33436
220301.22
01/23/2026RESUBMITTAL #2FLEX SUB
01/23/2026DRC
1/8" = 1'-0"A306
1COLOR EXTERIOR ELEVATION - NORTH
1/8" = 1'-0"A306
2COLOR EXTERIOR ELEVATION - SOUTH
2
2
NUM.DESCRIPTION DATE
2 SPA REV. 2 1/21/2026
APPROVED
Planning & Zoning
sevignyr 03/06/2026
PT-2PT-2
PT-1
PT-2
PT-1
PT-2
MT-2
PT-2PT-2 MT-1 PT-1PT-1
PT-2PT-2
PT-1
PT-2
PT-1
PT-2
MT-2
PT-2PT-2
PT-1
MT-1
MT-2
PT-1
PT-2
PT-1
PT-2
PT-2PT-2
PT-1
MT-1
PT-2
MT-2
PT-2PT-2 MT-1 PT-1PT-1
STOREFRONT NOTES
1. ALL EXTERIOR GLAZING SHALL BE LARGE MISSILE IMPACT RATED LAMINATED
GLASS BY VIRACON OR APPROVED EQUAL.
2. STOREFRONT FRAMES SHALL BE DARK BRONZE BY YKK OR APPROVED EQUAL.
3. GLASS SHALL BE 9/16" GRAY LAMINATED GLASS (1/4"/PVB/1/4"). VALUES AS
FOLLOWS:
U-VALUE: 0.93 WINTER NIGHT / 0.85 SUMMER DAY
SHGC: 0.50
VLT: 42 / REFLECTANCE 5%
MATERIAL LEGEND
COLOR MARK DESCRIPTION
PT-1
PT-2
MT-1
SMOOTH STUCCO PAINTED
SW 7006 - EXTRA WHITE
SMOOTH STUCCO PAINTED
SW 7659 - GRIS
STOREFRONTS, DOORS & GUTTERS
DARK BRONZE
MT-2 DREXEL METALS - ALUMINUM STANDING
SEAM ROOF - CHARCOAL FINISH
MT-3 STEEL PAINTED
SW 7659 - GRIS
MT-4 METAL DOOR & WALL PANEL PAINTED
SW 7006 - EXTRA WHITE
MT-4
MT-1
MT-2
MT-4
MT-4
MT-2
MT-4
REVISIONS
DRAWING NUMBER
JOB NUMBER
DATE
DRAWING TITLE
DRAWN BY
CONSTRUCTION
SEAL
ISSUED FOR :
BIDS
PERMIT
PROJECT TITLE
THIS DOCUMENT IS THE PROPERTY OF CURRIE SOWARDS AGUILA ARCHITECTS INC. ALL RIGHTS ARE RESERVED. ANY POSSESSION, REPRODUCTION OR OTHER USE OF THIS DOCUMENT, WITHOUT THE WRITTEN CONSENT OF CURRIE SOWARDS AGUILA ARCHITECTS INC., IS PROHIBITED.Architecture, Planning,
Interiors, &
Sustainable Design
AA26001584
185 NE 4TH AVENUE SUITE 101
DELRAY BEACH, FL 33483
THESE DRAWINGS ARE PREPARED PER
ESTABLISHED INDUSTRY STANDARDS AND
REPRESENT THE ARCHITECT AND
ENGINEERS DESIGN CONCEPT. THEY ARE
NOT INTENDED TO PROVIDE EVERY
DETAIL OR CONDITION REQUIRED TO
CONSTRUCT THE BUILDING. THE
CONTRACTOR THROUGH SUBMITTALS
AND OTHER COORDINATION EFFORTS IS
FULLY RESPONSIBLE FOR PROVIDING A
COMPLETE AND OPERATIONAL BUILDING
WHETHER INDICATED ON THE PLANS OR
NOT.
T:(561) 276-4951 F:(561) 243-8184
E-MAIL: office@csa-architects.com
SPA
JESS M. SOWARDS
AR0013205
1/22/2026 1:31:22 PM1/22/2026 1:31:22 PMBUILDING COLOR
ELEVATIONS
KB / JF
A307
HUNTERS RUN
RACQUET SPORT
CENTER
3500 CLUBHOUSE LN.
BOYNTON BEACH, FL.
33436
220301.22
01/23/2026RESUBMITTAL #2FLEX SUB
01/23/2026DRC
3/16" = 1'-0"A307
1 COMFORT STATION - COLOR FRONT ELEVATION
3/16" = 1'-0"A307
2COMFORT STATION - COLOR REAR ELEVATION
3/16" = 1'-0"A307
3COMFORT STATION - COLOR RIGHT SIDE ELEVATION
3/16" = 1'-0"A307
4COMFORT STATION - COLOR LEFT SIDE ELEVATION
3/16" = 1'-0"A307
5TENNIS MAINTENANCE - COLOR LEFT SIDE ELEVATION
3/16" = 1'-0"A307
6TENNIS MAINTENANCE - COLOR FRONT ELEVATION
3/16" = 1'-0"A307
7TENNIS MAINTENANCE - COLOR REAR ELEVATION
NUM.DESCRIPTION DATE
APPROVED
Planning & Zoning
sevignyr 03/06/2026
REVISIONS
DRAWING NUMBER
JOB NUMBER
DATE
DRAWING TITLE
DRAWN BY
CONSTRUCTION
SEAL
ISSUED FOR :
BIDS
PERMIT
PROJECT TITLE
THIS DOCUMENT IS THE PROPERTY OF CURRIE SOWARDS AGUILA ARCHITECTS INC. ALL RIGHTS ARE RESERVED. ANY POSSESSION, REPRODUCTION OR OTHER USE OF THIS DOCUMENT, WITHOUT THE WRITTEN CONSENT OF CURRIE SOWARDS AGUILA ARCHITECTS INC., IS PROHIBITED.Architecture, Planning,
Interiors, &
Sustainable Design
AA26001584
185 NE 4TH AVENUE SUITE 101
DELRAY BEACH, FL 33483
THESE DRAWINGS ARE PREPARED PER
ESTABLISHED INDUSTRY STANDARDS AND
REPRESENT THE ARCHITECT AND
ENGINEERS DESIGN CONCEPT. THEY ARE
NOT INTENDED TO PROVIDE EVERY
DETAIL OR CONDITION REQUIRED TO
CONSTRUCT THE BUILDING. THE
CONTRACTOR THROUGH SUBMITTALS
AND OTHER COORDINATION EFFORTS IS
FULLY RESPONSIBLE FOR PROVIDING A
COMPLETE AND OPERATIONAL BUILDING
WHETHER INDICATED ON THE PLANS OR
NOT.
T:(561) 276-4951 F:(561) 243-8184
E-MAIL: office@csa-architects.com
SPA
JESS M. SOWARDS
AR0013205
1/22/2026 1:31:24 PM1/22/2026 1:31:24 PMRACQUET CENTER
SECTION/DETAIL
KB / JF
A308
HUNTERS RUN
RACQUET SPORT
CENTER
3500 CLUBHOUSE LN.
BOYNTON BEACH, FL.
33436
220301.22
01/23/2026RESUBMITTAL #2FLEX SUB
01/23/2026DRC
2
NUM.DESCRIPTION DATE
2 SPA REV. 2 1/21/2026
APPROVED
Planning & Zoning
sevignyr 03/06/2026