23-009_Hunters Run_Pergola Plans-S1.00-FeedbackS1.00 COVER SHEET Site Location Map N.T.S. DESIGN INFORMATION 1.THE PROJECT WAS DESIGNED IN ACCORDANCE WITH THE FOLLOWING: -FLORIDA BUILDING CODE 7TH ADITION (2020) -WIND LOADS CALCUATED IN ACCORDANCE WITH ASCE 7-16 WIND SPEED: Vult = 170 MPH (ULTIMATE), Vasd = 132 MPH (NOMINAL) BUILDING RISK CATEGORY II EXPOSURE: C BUILDING DESIGNATION: OPEN MEAN ROOF HEIGHT LESS THAN 30'-0" 2. BUILDING DESIGNED FOR THE FOLLOWING SUPERIMPOSED DEAD AND LIVE RESIDENTIAL LOADS: -DEAD LOAD: 5 PSF -LIVE LOAD: 20 PSF 3. LOUVERS SHALL BE SPACES SUCH THAT THEY ALLOW A 50% SYSTEM POROSITY WHEN FULLY OPENED. SYSTEM IS NOT DESIGNED TO HANDLE CONCENTRATED LOADS FROM HUMAN ACTIVITY. 4. ALL STRUCTURAL COMPONENTS AND SYSTEMS SHALL BE DESIGNED FOR SELF WEIGHT, SUPERIMPOSED DEAD LOADS, CONCENTRATED LOADS SHOWN ON THE PLANS, AND THE LIVE LOADS SHOWN ABOVE. 5. DURING SUCH PERIODS OF TIME AS ARE DESIGNATED BY THE U.S. WEATHER BUREAU AS A HIGH WIND ADVISORY FOR THE AREA, THIS SYSTEM MUST BE LOCKED IN THE OPEN POSITION, WITH THE LOUVER BLADES VERTICAL, AND ANY FANS OR ACCESSORY COMPONENTS SHALL BE REMOVED. LOUVERS AND WINDSCREENS, IF SPECIFIED, SHALL BE RETRACTED PRIOR TO WIND SPEEDS OF 35 MPH. THE STRUCTURE SHALL ALSO NOT BE WALKED UPON AND IS NOT DESIGNED FOR HUMAN ACTIVITY OR STORAGE. THE STRUCTURE SHALL BE POSTED WITH A LEGIBLE AND READILY VISIBLE DECAL OR PAINTED INSTRUCTIONS TO THE OWNER OR TENANT STATING THAT: (1) THE SYSTEM IS NOT DESIGNED FOR HUMAN ACTIVITY (2) TO REPOSITION THE LOUVERS AND WINDSCREENS DURING WIND OR SNOW ADVISORIES. THE CANOPY OWNER SHALL BE NOTIFIED OF THESE CONDITIONS BY THE PERMIT HOLDER AT THE TIME OF SALE. SYSTEM SHALL BE EQUIPPED AND SOMFY CERTIFIED TO OPERATE PROPERLY WITH SENSORS WHICH WILL PROMPT THE LOUVER. GENERAL NOTES 1.ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD BY THE CONTRACTOR. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER BEFORE PROCEEDING WITH THE AFFECTED PART OF THE WORK. 2.ALL SPECIFICATIONS AND DOCUMENTS REFERRED TO IN THESE PLANS SHALL BE OF THE LATEST REVISION, UNLESS OTHERWISE NOTED. 3.WHENEVER A CONFLICT OCCURS BETWEEN ANY SPECIFICATION, ANY INFORMATION SHOWN ON THE PLANS AND/OR ANY REGULATORY REQUIREMENT, THE MORE STRINGENT REQUIREMENT SHALL APPLY. 4.THESE DRAWINGS SHALL NOT BE UTILIZED FOR CONSTRUCTION PRIOR TO OBTAINING REQUIRED PERMITS FROM ALL GOVERNMENTAL AGENCIES HAVING JURISDICTION OVER THE WORK. 5.ALL WORK PERFORMED SHALL COMPLY WITH THE REGULATIONS AND ORDINANCES OF THE VARIOUS GOVERNMENTAL AGENCIES HAVING JURISDICTION OVER THE WORK, INCLUDING STATE AND LOCAL BUILDING CODES. 6.CONSTRUCTION SHOWN ON THESE PLANS IS PERMITTED ONLY FOR THE WORK LOCATED WITHIN THE PRIVATE PROPERTY. ALL WORK WITHIN THE RIGHT-OF-WAY AND EASEMENTS WILL REQUIRE A SEPARATE PERMIT AND MAY REQUIRE AN ALTERATION TO THE CONSTRUCTION OR MATERIALS SHOWN ON THESE PLANS. FOUNDATION 1.FOUNDATION ARE DESIGNED FOR AN ASSUMED ALLOWABLE SOIL BEARING PRESSURE OF 2000 PSF. 2.FOOTING SHALL BE EXCAVATED TO CLEAN SOIL, FREE OF VEGETATION AND DELETERIOUS MATTER, AND CONCRETE SHALL BE PLACED ON AN UNDISTURBED BASE. 3.CONTACT ENGINEER OF RECORD (EOR) IMMEDIATELY IF ANY UNDERGROUND STRUCTURES, FOUND DURING EXCAVATION, IMPEDE THE COMPLETION OF CONSTRUCTION AS SHOWN. CONCRETE 1.CONCRETE SHALL ACHIEVE A 28-DAY STRENGTH OF 3000 PSI WITH A FIBER CONTENT OF 1.5 LBS PER CUBIC YARD. 2.CONCRETE SHALL BE PLACED AND CURED ACCORDING TO ACI STANDARDS AND SPECIFICATIONS. 3.FORMWORK SHALL COMPLY WITH ACI 347, 'RECOMMENDED PRACTICE FOR CONCRETE WORK.' CONCRETE ANCHORS: 1.EPOXY SHALL BE HILTITM HIT HY 150 MAX. 2.CONCRETE SCREWS SHALL BE HILTITM KWIK-CON II. 3.EXPANSION BOLTS SHALL HAVE A LENGTH IDENTIFYING LABEL AND BE HILTITM KWIK-BOLT 3 OR EQUAL. FASTENERS: 1.ALL FASTENERS TO BE A MIN. #12 X 1-1/2" OR GREATER 18-8 SERIES 300 NON-MAGNETIC ALLOY, STAINLESS STEEL, OR CADMIUM PLATED OR OTHERWISE CORROSION RESISTANT MATERIAL AND SHALL COMPLY WITH APPLICABLE CODES. REINFORCING 1.REINFORCING BAR SHALL HAVE A MINIMUM YIELD STRENGTH OF 60 KSI AND CONFORM TO ASTM 615. SPLICES SHALL BE IN ACCORDANCE WITH ACI 318-08 FOR "STRENGTH DESIGN." FABRICATION AND PLACING OF STEEL SHALL BE IN ACCORDANCE WITH ACI CODE STANDARDS AND PRACTICE PROCEDURES. 2.MINIMUM CONCRETE COVER FOR REINFORCEMENT: A.CONCRETE CAST AGAINST EARTH AND PERMANENTLY EXPOSED TO EARTH - 3" B. CONCRETE EXPOSED TO EARTH OR WEATHER #5 BAR AND SMALLER - 1 1/2" ALUMINUM 1.ALUMINUM MATERIAL: SHEET METAL IS 5052-H32 UNDER ASTM B209. EXTRUSIONS ARE 6063-T5 UNDER ASTM B221, STRUCTURAL IS 6061-T6 UNDER ASTM B211 WITH FTY=35 KSI AND FTU = 38 KSI, UNLESS OTHERWISE STATED. ALUMINUM WELDS SHALL USE 5356 ALLOY WITH MINIMUM SHEAR STRENGTH OF 17 KSI. ALL WELDING TO CONFORM TO AWS STANDARDS. ALL BOLTS AND SCREWS IN CONTACT WITH ALUMINUM ARE STAINLESS STEEL A304/A316. 2.ALUMINIUM WELDING: SHALL BE PERFORMED IN ACCORDANCE WITH 2020 FBC SECTION 2003.8.1.4 WITH WELD FILLER ALLOYS MEETING ANSI/AWA A5.10 STANDARDS TO ACHIEVE ULTIMATE DESIGN STRENGTH IN ACCORDANCE WITH THE ALUMINUM DESIGN MANUAL PART I-A, TABLE 7.3.1. SUGGESTED WELD FILLER: 5356 ELECTRODES. ALL ALUMINUM CONSTRUCTION SHALL BE IN CONFORMANCE WITH THE TOLERANCES, QUALITY AND METHODS OF CONSTRUCTION AS SET FORTH IN FBC SECTION 2003.2 AND THE AMERICAN WELDING SOCIETY'S STRUCTURAL WELDING CODE-ALUMINUM (D1.2). MINIMUM WELD IS 1 8" THROAT FULL PERIMETER FILLET WELD UNLESS OTHERWISE NOTED. 3.CONTRACTOR SHALL INSULATE DISSIMILAR MATERIALS TO PREVENT ELECTROLYSIS PER FBC. 4.CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO FABRICATION AND INSTALLATION. ABBREVIATIONS (NOT ALL ARE USED) AB ANCHOR BOLT ACI AMERICAN CONCRETE INSTITUTE BLDG BUILDING BRG BEARING CONC CONCRETE DIA DIAMETER DL DEAD LOAD DWG DRAWING EA EACH EOR ENGINEER OF RECORD EL ELEVATION EW EACH WAY EXT EXTERIOR FBC FLORIDA BUILDING CODE FTG FOTTING LL LIVE LOAD MPH MILES PER HOUR MIN.MINIMUM OC ON CENTER PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH REQD REQUIRED TYP TYPICAL VIF VERIFY IN FIELD W/ WITH ALUMINUM PERGOLA CONSTRUCTION PLANS SHEET INDEX SHEET NUMBER SHEET TITLE S1.00 COVER SHEET S2.00 ISOMETRIC PERGOLA PLAN S3.00 PERGOLA PLAN S4.00 PERGOLA DETAILS S4.01 PERGOLA DETAILS S5.00 HORIZONTAL LOUVER DETAILS S5.01 HORIZONTAL LOUVER DETAILS Drawn by DateRevisionNo. AD Checked by JD DATE: SHEET NUMBER SHEET TITLE ISSUED FOR DATE CONSTRUCTION PROJECT DeYoung Design & Engineering, LLC 8112 Dean Street Riverview, FL 33578 813.767.7070 August 13, 2023ALEXANDRA L . DE Y OUNGALORISTATE OF F D NS SEFORP LANOI E NIG REENo. 82327 L I C E NSE I CERTIFY TO THE BEST OF MY KNOWLEDGE THAT THESE DRAWINGS & SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES This item has been digitally signed and sealed by Alexandra L. DeYoung, PE on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. 8/13/2023 HUNTERS RUN COUNTRY CLUB 3500 CLUBHOUSE LANE BOYNTON BEACH, FL 33436 PARCEL NO: 08424601040000010 APPROVED APPROVED APPROVED APPROVED APPROVED APPROVED APPROVED APPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVED APPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVED Planning & Zoning Division November 30, 2023 Project #: ___________________________MMSP 2023.11.87601