Loading...
HomeMy WebLinkAboutComposite UtilityS N89°24'17"W 1000.61' C/P UTILITY EASEMENT (O.R.B. 11611, PG. 697, P.B.C.R.) UTILITY EASEMENT (O.R.B. 22049, PG 690 CONC. WALKUTILITY EASEMENT (P.B. 46, PG. 58, P.B.C.R.) UTILITY EASEMENT (O.R.B. 11611, PAGE 697 P.B.C.R)UTILITY EASEMENT(O.R.B. 22049, PG 690WATER & SEWER EASEMENT (O.R.B. 28453, PG. 245, P.B.C.R.) EXISTING (ELEMENTARY BLDG.) FPL EASEMENT (O.R.B. 21841, PAGE 268 P.B.C.R) RESTROOM 15' FPL EASEMENT (O.R.B. 11825, PAGE 1467 P.B.C.R) EXISTING ONE STORY C.B.S. SCHOOL BUILDING FIN. FL. EL.= 31.40 BASKETBALL COURT PLAYGROUND ONE STORY C.B.S. FIN. FL. EL.= 30.45 S89°24'09"E 1316.29' (C/M) ( IN FEET ) GRAPHIC SCALE 0 1 inch = ft.20 10 20 40 60 Know what's below. before you dig.CallR www.callsunshine.com DESCRIPTION:PROJECT:MICHAEL B. SCHORAH& ASSOCIATES, INC.1850 FOREST HILL BLVD., SUITE 206WEST PALM BEACH, FLORIDA 33406EB# 2438TEL. (561) 968-0080FAX. (561) 642-9726LB# 2438ENGINEERS SURVEYORS DEVELOPMENT CONSULTANTSDRAWN/CHECKED:DATE:REVISIONSSCALE:DATE:www.schorah.comPath\Name : P:\1938 LWC ELEMENTARY PHASE 2\CIVIL\CAD\1938 COMPOSITE UTILITY 4-23-26.dwgDate\Time : Tue, 02 Jun 2026 - 2:10pmMAM/MJL1" = 20'APRIL 20261 1 1938LAKE WORTH CHRISTIAN SCHOOLELEMENTARY EXPANSION PHASE 2COMPOSITE UTILITY PLANMICHAEL J. LACOURSIERE, P.E.FLORIDA LICENSE #41071FOR MICHAEL B. SCHORAHAND ASSOCIATES, INC.LEGEND PROPOSED VALVE PROPOSED FDC PROPOSED METER PROPOSED CLEANOUT PROPOSED DOUBLE DETECTOR CHECK VALVE ASSEMBLY EXISTING CLEAN OUT EXISTING YARD DRAIN PROPOSED B.B.U.E. EXISTING UTILITY EASEMENT EXISTING FPL EASESMENT ROOF DRAIN OVER SANITARY LATERAL CONTRACTOR TO VERIFY LOCATION, SIZE, AND DEPTH OF FPL CONDUIT. CONTRACTOR TO REPORT MEASURED CONDITION AND PROPOSE CROSSING AND CORE ENTRY ELEVATIONS TO ENGINEER FOR REVIEW ROOF DRAINAGE OVER SANITARY 12" HDPE @ 0.50% (MIN.) 12" HDPE @ 0.50% (MIN.) 8" HDPE @ 0.50% 8" HDPE @ 0.50% 12" HDPE @ 0.50% (MIN.) EXISTING 2" WATER SERVICE 83' - 4" PVC (SDR 26) @ 2.08% (MIN.) PRIVATE OIL/WATER SEPARATOR WITH INSPECTION PORTS PER CITY OF BOYNTON BEACH UTILITIES DETAIL 11A EXISTING 4" FIRE LINE EXISTING 6" PVC SDR 26 SERVICE LATERAL (TYP.) EXIST. 8" W.M. EXIST. 8" SAN. EXIST. 8" SAN. EXIST. FIRE HYDRANT EXIST. 8" W.M. EXIST. 6" SAN. (PRIVATE) EXIST. 6" SAN. EXIST. 15" HDPE EXIST. 15" HDPE EXIST. 15" HDPE EXIST. 15" HDPE EXIST. 15" HDPE EXIST. 12" PVCEXIST . 12 " PVC EXIST. 12" HDPE EXIST. 18" HDPE EXIST. DRAINAGE INLET INLINE DRAIN TOP EL. 29.10 EXTERIOR DOWNSPOUT (TYP.) 8" HDPE @ 0.50% (MIN.)UTILITY PROVIDERS: Water/Fire Supply: City of Boynton Beach Utilities Sanitary Collection: City of Boynton Beach Utilities* *connection to private lateral only for this phase Drainage:Lake Worth Christian School Power:FPL Gas:Gas service is not proposed. Telecommunications: Supplied through existing service located within adjacent bldg.. No additional lines required.EXIST. 12" HDPE EXIST. 12" HDPE EXIST. 12" HDPE EXIST. 12" HDPE EXIST. 8" W.M. EXISTING FPL TRANSFORMER ON POLE EXISTING ELECTRICAL CONDUIT FOR SUPPLY TO BUILDING EXISTING EMPTY PANEL WITH METER RECEPTACLE ON BUILDING FPL SERVICE _________________________________________ Name of Utility Provider _________________________________________ Email / Mailing Address _________________________________________ Utility Rep. Name & Title (PRINTED) _________________________________________ Utility Rep. Signature Date Florida Public Utilities _________________________________________ Name of Utility Provider _________________________________________ Email / Mailing Address _________________________________________ Utility Rep. Name & Title (PRINTED) _________________________________________ Utility Rep. Signature Date AT & T g44488@att.com Timothy Gibbs, Design OSP Engineer 06/02/26 _________________________________________ Name of Utility Provider _________________________________________ Email / Mailing Address _________________________________________ Utility Rep. Name & Title (PRINTED) _________________________________________ Utility Rep. Signature Date Comcast 04/24/26 _________________________________________ Name of Utility Provider _________________________________________ Email / Mailing Address _________________________________________ Utility Rep. Name & Title (PRINTED) _________________________________________ Utility Rep. Signature Date Florida Power & Light Company 04/24/26 _________________________________________ Name of Utility Provider _________________________________________ Email / Mailing Address _________________________________________ Utility Rep. Name & Title (PRINTED) _________________________________________ Utility Rep. Signature Date City of Boynton Beach Utilities Dept. 04/25/26 daniel_tiburcio2@comcast.com Daniel Tiburcio - Comcast PBC Construction Dept. easementconsent@bblf.us Milot Emile, P.E., Principal Engineer Engineering-wpb@fpuc.com DCP-Group.SharedMailbox@nexteraenergy.com Florian Mendesse Elowelynn Reilly Admin. Assistant, Engineering Services Florida Public Utilities 04/30/2026 FPU Milot Emile APPROVED APPROVED APPROVED APPROVED APPROVED APPROVED APPROVED APPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVED APPROVEDAPPROVEDAPPROVEDAPPROVEDAPPROVED Planning & Zoning Division August 04, 2026 Project #: ___________________________2026.03.1662