Loading...
REVIEW COMMENTS M E M 0 RAN DUM Octobe:J; 5, 1988 TO: Mr. Jim Golden Senior City Planner FROM: Tom Clark City Engineer RE: Preliminary Plat and Site Plans for Quail Run, Phase II COMMENTS: l. The tracts that are re-platted should be identified on the plat plan with their former identification also. 2. A construction permit will be required from the Water Management District and the Lake Worth Drainage District. 3. A cost estimate for the bonded improvements is required. 4. The existing and/or proposed bank slopes, dimensions and elevations should be shown on the lake outfall section including the elevation of the lake bottom and the width of the seed and mulch area. 5. Complete street lighting plans are required including structural and electrical details unless done by F.P. & L. Co. If done by F.P. & L. Co. a note will be required so stating, subject to approval of plans by the City. 6. Unless an easement is provided for street light poles, the sidewalks for sections A-A and B-B should be moved a foot from the R.O.W. 7. Current bond includes $30,400 for street lights for Golf Road, S.W. 26th Avenue and Woolbright Road. This cost should be checked with F.P. & L. Co. and additional costs included as a line item in the cost estimate. 8. The width of the private ingress/egress rights-of-way tracts should be shown on the plat plan. 9. A cross-section is required thru the private streets to show the swale construction. 10. The depth of the swale for the 60 ft. R.O.W. should comply with City standards, ie., 0.70 ft. instead of 0.52. con' t. . . . . . To: Mr. Jim Golden October 5, 1988 Re: Preliminary Plat & Site Plans for Quail Run, Phase II (con't.) Page #2 11. The Tract R-3 is out of scale at dog leg curve when compared with curve data. l2. Refer to Bill Flushing's memo of September 30, 1988. ~v~ aJ Tom Clark TAC/ck attachment - TRB MEMORANDUM September 30, 1988 To: Tom Clark From: Bill Flushing Re: Quail Run - Phase II Plat 1. Tract "D" is missing a PCC on the easterly boundary. 2. The correct area is 12.0508 Acres, not 12.2751 as shown. The units per acre will then equal 9.63 instead of 9.45 Tract "CIf :: 4.80606 acres Tract IfD" :: 3.6.6552 acres Tract "E" :: 3.57923 acres 3. A statement is required absolving the city from any responsibility for the control of aquatic weeds (City code Appendix C Art. VIII Sec. 6 D. 11). 4. The proposed private streets must be named. 5. Pcp's are required for the private streets. 6. Boundary bearings should be consistent in a CW or CCW direction (see Tract "c" N 530 30' 00" E should be S 530 30' 00" W). 7. In providing the legal description in the dedication, the surveyor is using the most extreme interpretation of Chapter 177.0" (11). In my opinion, although it is technically acceptable, it does not comply with the intent of Chapter 177. Over 95% of the surveyors who prepare Plats in Boynton Beach would have used a metes and bounds for Tracts ,IfC", IfD", and liE". ~ 8. If the finished lake shore line is to encroach or be close to the plat boundary line, the shore line must be shown on the plat. .,..... - - Construction Plans 9. Handicap parking striping to be shown as being blue. 10. Sign detail should include the mounting post with embedment. 11. Section C-C parking detail should clearly show that the grade (for drainage) is going toward the center planting area. Bill Flushing ",' - MEMORANDUM October 5, 1988 TO: CHAIRMAN AND MEMBERS PLANNING AND ZONING BOARD FROM: CARMEN S. ANNUNZIATO, PLANNING DIRECTOR RE: QUAIL RUN, PHASE II - STAFF COMMENTS Please be advised of the following Planning Department comments with respect to the above-referenced site plan request: 1. Revise setback data on site plan sheet 2 of 9 as follows: A. Side (from S.W. 26th Street). . . 25' B. Building Separation.. ... 20' C. Rear. . . . . . . . . . . . . . . 20' 2. Dimension a typical driveway at a minimum of 9 feet by 18 feet consistent with previously approved parking lot variances. 3. No lighting plan has been provided for the visitor parking lots or lights attached to the unit exterior lighting the driveways. The lighting plan should include location, manufacturer's specification, energy source, pole detail, illumination level, photocell activation and wattage. The previously approved lighting variance did not exclude lighting these areas. 4. Include C.A.B. approved landscape plan, and previously approved building elevations and signage program with final sign-off drawings. 5. A back up of twenty-seven (27) feet is required for visitor parking lots. (Appendix B of Article X, Parking Lots.) CA~~..~N~ CSA:ro cc Central File