CORRESPONDENCE ~@~1I \'V r:" ...,,,-- , \~J ~, i - , " , i i ~ ~ \ I; 1 i) I IW BUILDING D:rv:rSION ill MEMORANDUM NO. 96 -217 June 11, 1996 PLANNING AND ZONING DEPT. TO: Technical Review Committee Members Marshall Gage Bob Eichorst Charlie Frederick John Guidry Tambri Heyden Floyd Jordan 'Police Chief Public Works Director -Recreation & Park Director Utilities Director Planning & Zoning Director Fire Chief FROM: Don Johnson, Building Compliance Administrator RE: ISSUANCE OF CERTIFICATE OF OCCUPANCY Racetrac,Petroleum 905 W. WOOLBRIGHT WAAS PHILLIPS The above referenced project is nearing completion. Prior to the Building Division issuing the Certificate of Occupancy, I would like to ensure that you do not have any outstanding or pending conditions concerning this site that must be rectified (excluding issues that are covered entirely with a city approved surety) . If any outstanding conditions are related to permits issued by the Building Division, please provide this division a memorandum containing a description of the unresolved conditions. If the unresolved conditions are not permit related, please notify the owner or the owner's agent to ensure that the matters are rectified. Please respond to me, within ten (10) days in order that we may proceed in a timely manner to issue the Certificate of Occupancy. No response is necessary if your department is satisfied with the current state of the above referenced site. Thank you for your cooperation. A:TRCMEMO ~~~ -DoN ..' . /- I~ f>fC-OPt-QTy O;.UtJt..R. ;/45 ~ f'G.5,oOMSIBlt/ty TO SJ.8/H,T___ ~ fAfAt gt:()tllu>i/lVTy Re~h.f)i.D U,{)~ df r; rI.L s:1i6-..v;Alb 7rJ:. ios to. tlJObt..8/2./t;;.# 11M S/~ Qy?18/A/60 WITf/ ~ . It 8urri,vc. ftU>fJt:~1 1b TNt 1u6t; r. 71J= AglJ iTi,v(. f}.of.E~ij , I~ ()v.JAI~ 117 RMbT/2Ac. ~AI.9 IS t,(JW:(l~ J7I6 a..v~~,"u 7klJd.-r::.fL -- /~ 4,~. 71/J: {/M'7 "J 7:* S~ /iL:./tk<!:!J fr-' '1)JC~~rfLc, ~ r/~ ,,/';J/9' // ' ~.~._-,. .,-e:--:-....~ xc: Carrie Parker Kevin Hallahan Jim DuVali 'c"I' . "\~"-'" ,......~...: y,~";::"'I':"""",~,.....- PLANNING AND ZONING DEPARTMENT MEMORANDUM NO. 93-049 March 18, 1993 TO: Robert Eichorst, Public works Director vince Finizio, Admin. Coordinator of Engineering Richard staudinger, Gee & Jenson Al Newbold, Deputy Building official Bill Cavanaugh, Fire Prevention officer Mike Kazunas, utility Engnieer Lt. Don Thrasher, Police Department John Wildner, Parks Superintendent Kevin Hallahan, Forester/Environmentalist ~>~b:'l :C' FROM: Christopher cutro, Planning & zoning Director RE: Second Review - site Plan Project Location Applicant File No. - Racetrac Gas Service station N.W. corner of S.W. 8th street Racetrac Petroleum, Inc. 724 and Woolbright Road Attached is the amended site plan for the above referenced development for your final review and recommendation. We would ask that you review this amended site plan to determine if the plans have been adjusted to satisfy comments made previously by your department. If the comments have been satisfied or if your comments can be met at time of building permit, please advise the Planning and Zoning Department in writing. If your comments have not been met or must be met by correcting the site plan again, please advise the Planning and Zoning Department in writing. Finally we would ask that you recommend to us if the plan should be forwarded to the Planning and Development Board/Community Redevelopment Advisory Board for review or held for further revisions by the applicant. All correspondence shall be received by the planning and zoning Department per the following: Please return your memo and the amended plans to the Planning and Zoning Department by 5:00 P.M. on March ~5, 1993. If you should have any questions regarding this plan, please feel free to call Dotty Moore at 260 who is coordinating the review of this development. XC: (Memo Only) Don Jaeger Ed Allen charlie Frederick Edward Hillery John Guidry Project File Chronological File A: 2REVIEW. WP5 J r, Ie..l> 'fbtlowu,," \(\ e ~ -r ~J;V J l2.lV' ------ ,- KEHORANDUX FROM: SUBJECT: Chris Cutro, Director of Planning~~ ~ James A. Cherof, city Attorney ~~- Code Interpretation, Parking Lot Driveways for Service stations TO: DATE: March 1, 1991 You have asked me to examine an apparent conflict between section 11 L 5 of Appendix A of the Zoning Regulations and Section 5- 142 (h) (3) as they relate to setback requirements for driveway entrances from intersecting right-of-ways. stated differently, you have posed the following question: Should the requirements of the Boynton Beach Parking Lot Regulation be applied to the construction of driveway entrances for service stations? The question is answered in the negative. There are several principals of statutory construction that must be applied: 1. The principals of statutory construction apply to zoning ordinances which are issued by cities. Rinker Materials Corp. v. city of Miami, 286 So.2d 552 (Fla. 1973). 2. The general, and most persuasive rule of statutory construction is that whenever possible, the Courts will, and must, attempt to construe related statutory provisions, if conflicting, in such a way as to harmonize them and give them both full effect. Palm Harbor Soecial Fire Control District v. Kellv, 516 So.2d 249 (Fla. 1987); villery v. Florida Parole and Probation Commission, 396 So.2d 1107 (Fla. 1980); District School Board of Lake County v. Talmadqe, 381 So.2d 698 (Fla. 1980). 3. Where a statute is passed with knowledge of prior existing laws, construction is favored which gives each statute a field of operation rather than a construction that would leave one statute meaningless or released by implication. State Del;)artment of Public Welfare v. Galilean Children's Home, 102 So.2d 388 (Fla.~DCA 1958). 4. law and Since zoning ordinances are in derogation of the common deprive owners of th~jf<:~r -property, any MAR 1 q \.= . ambiguities which may arise from conflicting zoning ordinances should be resolved in favor of the property owner. Thomas v. Citv of Crescent city, 503 So.2d 1299 (Fla. 5th DCA 1987). 5. Courts must also give specific, terms and provisions precedence over those terms and provisions which are more general in nature if the two provisions conflict. Lake Barrinaton citizens Commission v. Villaqe of Lake Barrington, 312 NE.2d 337 (1974). In applying the above rules of statutory construction to the question posed I conclude that the two provisions of the Code are not in conflict and can be read together. The parking lot regulations should be generally applied to all parking lot construction unless a more specific ordinance of the City exists, such as the one which applies to service stations. The Boynton Beach parking lot regulation does not apply to the construction of driveway entrances for service stations. Section 11 L 5 of Appendix A controls the distance requirements for parking lot entrances for service stations. Ilms LIB CUTROMEM cc: J. Scott Miller, City Manager Don Jaeger, Building Official Vince Finizio, Administrator Coordinator of Engineering rJ fI, . Ih.~-" O)'u..ru'-1)_ /\ a..A,~~U<.-- )VU........ ~ ~~.. TECHNICAL REVIEW COMMI'rI'EE MEMORANDUM TO: Robert Eichorst, Public Works Director Al Newbold, Deputy Building Official William Cavanaugh, Fire Prevention Officer Lt. Don Thrasher, Police Department John Wildner, Parks Superintendent Kevin Hallahan, Forester/Environmentalist Mike Kazunas, Utilities Engineer Vincent Finizio, Administrative Coordinator of Engineering Richard Staudinger, Gee & Jenson Consulting Engineers FROM: Dorothy Moore, Zoning & Site Plan Reviewer DATE: February 16, 1993 RE: Technical Review Committee Meeting Tuesday, February 23, 1993 Please be advised that the Technical Review Committee will meet on Tuesday, February 23, 1993, at 9:00 A.M. in Conference Room "c" (West Wing) to discuss the following: REVIEW OF TECHNICAL REVIEW COMMENTS: MASTER SITE PLAN MODIFICATION PROJECT NAME: Waste Management of Palm Beach, Inc. Parking Lot Expansion APPLICATION: John A. Grant, III LOCATION: 651 Industrial Way FILE NO. 720 rrfie City of :Boynton'13eac/i Planning & Zoning'lJepartTlUnt 100 'E. 'Boynton 'Bea&. 'Boufe.vara P.O. 'Bo;C310 'Boynton 'B~:J1oritfa 33425-0310 (407) 738-7490, ~JU: (407) 738-7459 February 12, 1993 Mr. Mike Morton Tradewinds Group Congress Corporate Plaza 902 Clint Moore Road, Suite 124 Boca Raton, FL 33487 (407) 994-3133 RE: Acceptance - Site Plan Review Application & Submittal Document~ New Site Plan - Racetrac Gas Service station File No. 724 Mr. Mc;.rton: On February 12, 1993, your submittal for Site plan Review of the above referenced project was reviewed for completeness. It has been determined that the submittal is substantially complete and acceptec for further processing. Dorothy Moore will be responsible for the review and coordination of your site plan thru the remainder of the site Plan Review process. The next step in the review process is for the Technical Review Committee to review the submittal for compliance with the review standards identified in Part III, Land Development Regulations, Chapter 4, Site Plan Review, Section 8 and all applicable sections of the Boynton Beach code of ordinances. The results of the review will be forwarded to you within twenty (20) days of the date identified in the first paragraph of this letter. If I can be of further assistance, please do not hesitate to contact me. Very truly yours, ~~'--/ ~ Christopher cutro Planning and Zoning Director xc: central File Chronological File Project File Project ~< j~ PLANNING AND ZONING DEPARTMENT MEMORANDUM NO. 93-033 TO: Robert Eichorst, Public Works Director Vince Finizio, Admin. Coordinator of Engineering Richard staudinger, Gee & Jenson Al Newbold, Deputy Building Official Bill Cavanaugh, Fire Prevention Officer Michael Kazunas, Utilities Engineer Lt. Don Thrasher, Police Department John Wildner, Parks Superintendent Kevin Hallahan, Forester/Environmentalist "j L"~ FROM: Christopher cutro, Planning & Zoning Director DATE: February 12, 1993 RE: SITE PLAN REVIEW PROCEDURES Plan - Racetrac Gas Service Station - NW corner of SW 8th Street and woolbright Road at Woolbright Place, PUD Applicant - Racetrac petroleum, Inc. File No. - 724 New Site Project Location Find attached for your review the plans and exhibits for the above referenced project. Site Plan Review approval for this project will be granted by the City Commission. To ensure that the project stays on line with the review time frame, I request that the plans and exhibits be reviewed and formal comments transmitted to the Director of the Planning and Zoning Department no later than 5:00 P.M. on February 19, 1993. Adhering to the following review gUidelines will promote a comprehensive review and enable the applicant to efficiently obtain Technical Review Committee approval: 1. Use the review standards specified in Part III, Land Development Regulations, Chapter 4, Site Plan Review, Section 8 to review and formulate comments. (See Planning & Zoning Department memo #92-020) 2. The documents submitted for the project were determined to be substantially complete based on the submittal requirements identified in Section 7 of the site Plan Review Ordinance. However, if the data provided to meet the submittal requirements is insufficient to properly evaluate and process the project based on the review standards, additional data should be requested by the reviewer through the Planning and Zoning Department. PLANNING AND ZONING DEPARTMENT MEMORANDUM NO. 93-087 TO: Don Jaeger, Building Official --<'! f ,fJrr,f fD IL FROM: Chris~her Cutro, Planning and Zoning Director DATE: April 29, 1993 RE: TRANSMITTAL OF APPROVED SITE PLAN FROM THE APRIL 20, 1993, CITY COMMISSION MEETING Accompanying this memorandum you will find the approved S1~e plan package for the project(sj listed below. The site plan package will include the following items: 1. A copy of the City issued approval letter 2. A copy of the comments made by the Technical Review Committee (TRCj 3. A set of plans reviewed by the TRC Racetrac Gas Service Station: Construction of a convenience store with gaslone sales. The Site Plan was approved with conditions by the City Commission at their regular meeting held on April 20, 1993. CC:ald Attachments XC: (Memo Only) Al Newbold Central File Project File %e City of 'Boynton 13eac/i Pfanning & Zoning 'Departnunt 100 'E. 'Boynton 'BeD.€.!i 'Bouftvara P.O. 'Bo~31O 'Boynton 'Betun. ~foritfa 33425-0310 (40i) i38-i490, ~5tX: (40i) i38.i459 ., April 28, 1993 Mr. Michael Morton Tradewinds Group 902 Clint Moore Road suite 124 Boca Raton, FL 33487 Re: Racetrac Gas Service station Dear Mr. Morton: 'rhis is to advise you that on April 20, 1993, the City Commission of Boynton Beach approved the Site Plan at the above referenced location. The approval of the Site Plan was subject to the following conditions: 1. Moving the dumpster enclosure to the Northwest corner of the site; 2. Adding landscaping to the drainage area at the northwest corner of Woolbright Road and Southwest 8th street; 3. Subject to all outstanding comments from reviewing departments and attached to the city commission back-up. The Site Plan approval entitles you to develop the property as shown on the approved plans. If you wish to modify the plan prior to submission of your building plan, please contact the Planning and Zoning Department. Modifications during the building permit process will be handled as part of that process. The approval of the Site Plan remains in effect for one year, until April 20, 1994. If an extension is needed, please forward your request to the planning and Zoning Department 30 days prior to the expiration date. We have attached a list of submittal documents from the Building Department to assist you in assembling your building permit package. We have also attached copies of the comments that must be met in the building permit submittal. ~ ....a rll c;.e> '1=0 ; low, ~ ~12 S T ~-evIeJ</ ------ /" MEMORANDUM No. 91-112 May 7, 1991 FROM: Chris Cutro, Planning Director James A. Cherof, City Attorney ~ Service Stations/Required Frontage Code Reference: Appendix A Section 11 L 2 TO: RE: You have referenced code measurement for essence is: requested clarification of the above section with respect to the points of determining frontage. Your question in When a service station is located on the corner of two intersecting streets should frontage be measured from the point of intersection of the property lines at the corner? Your question is answered in the affirmative. Section 11 L 2 of Appendix A provides that the minimum frontage for service stations is 175 feet on all abutting streets. No specific method of measurement is provided. However, the Boynton Beach Parking Lot Regulations, adopted after Section 11 of Appendix A, provides guidance for purposes of interpretation. Section 5-142(h)(3) deals with driveway set-backs and provides that the measurement is "from the intersection of the right-of-way lines along local streets". This appears to be a practicable approach to the measurement of frontage since lot configurations are variable. Accordingly, this method of measurement should be used to calculate frontage. For purposes of clarification I have attached a diagram. . If you require further clarification, please do not hesitate to contact me. cc: J. Scott Miller, City Manager --- ~~ TECHNICAL REVIEW COMMITTEE MEMORANDUM TO: Robert Eichorst, Public works Director Al Newbold, Deputy Building Official Will~am Cavanaugh, Fire Prevention Officer Lt. Don Thrasher, Police Department Jo~n Wildner, Parks Superintendent Kevin Hallahan, Forester/Environmentalist Mike Kazunas, utilities Engineer Vincent Finizio, Engineering Department Richard Staudinger, Gee & Jenson Consulting Engineers FROM: Dorothy Moore, Zoning & Site Plan Reviewer DATE: Ha::..-ch 22, 1993 RE: Technical Review Committee Meeting Tuesday, March 30, 1993 Please be advised that the Technical Review Committee will meet on Tuesday, Mar:h 30, 1993, at 9:00 A.M. in Conference Room "Ct' (West Wing) to discuss the following: MASTER PLAN MODIFICATION PRCJECT N.Zl..ME: Shoppes of Woolbright P.C.D. AGENT: Kilday & Associates LOCATION: Home Depot/Garden Center Corr-mercial Area East of S.W. 8th Avenue FILE no. ..,..,.., .' ~....; PLEASE SEE AT~AC~ED PROJECT NO. 421.1/945.6. PLEASE SEE AT~AC3E~ PROJECT NO. 421.1/1070.1. I.1':J ':'E : Pl=~se ~e~~~~ all plans and comments for the prJject2 to the planning and Zoning Director ~hu~sday, 5:00 p.m., April 1, 1993. a:tov3 ~"'i;r ~.l TechLical Review Committee Page 2 DISC.JSSION 1. Eeview of the foll~)wing site plal:'~3 for inter-departmental conflicts: a. Shoppes of Eoy~ton - PolIo Tropical Restaurant Leased outpa~cel b. Barnett Bank of Palm Beach CJunty Ambulatory Surge~y i EndoscoP7 Center Conditional Use ., a. Shoppes of BoyntJL Pallo Tropical Restaurant Leased Outparcel DoQ:::!Ay'~ .2 DM/jrn Att. cc: J. Scott Miller, City Manager 2ity Commission (5) Don Jaeger, Building Official Ed Allen, Fire Chief Charles Frede~ick, Recreation & Parks Director Edward Hillery, Police Chief Joh~ Guidry, utilities Director Steve Campbell, Fire Department B0b Gibson, Public Works central File Christopher cutro, Planning & Zon~ng Director Tambri Heyden, Senior Planner Mike Haag, Zoning and site Development Administrator Proje::t File Chronological File A:TRCTUES.JH April 9, 1993 Mr. Chris Cutro City of Boynton Beach 100 E. Boynton Beach Blvd. P.O. Box 310 Boynton Beach, Florida 33425-0310 RE: Racetrac Petroleum Site at Woolbright Road Dear Mr. Cutro: Please accept this letter as an Agreement that the above-referenced Site will continue with the Site Plan Review. It is understood that the Building Permit will not be issued until such time as the Forced Main crossing our Site is relocated and that the Gravity Service Line is in operation and accepted by the City of Boynton Beach. According to plans approved in 1990. If you have any questions, please feel free to contact me at (404) 431-7600, ext. 1125. Sincerely, N~~ Nolan Sims Qf Project Manager enclosures cc: John Guidry, Boynton Beach Utilities Joe Kolb, CCL Consultants Mike Morton RECEIVED APR .12 . - PLANNING DEPT~ - ~ RACETRAC PETROLEUM, INC. P.O. Box 105035, Atlanta, Georgia 30348,5035 (404) 431,7600 '- ! I f tlJ~ ~, CCl CONSULTANTS, INC!~fl~,f!, " . Consulting Engineers Surveyors Planners 2200 PARK CENTRAL BLVD., N, SUITE 100, POMPANO BEACH, FL 33064, (305) 974-2200 · FAX (305) 973-2686 May 6, 1993 Mr. Christopher cutro, Planning & Zoning Director CITY OF BOYNTON BEACH 100 E. Boynton Beach Blvd. Boynton Beach, Florida 33425-0310 RE: Racetrac Gas station Engineer's Project No. 3197 Dear Mr. Cutro: On behalf of our client, Racetrac Petroleum, Inc., we are submitting a letter from Barton-Aschman addressing the traffic related issues brought forth during our recent site plan approval. By copy of this letter, I am also sUbmitting this to Richard Staudinger for his review. Please provide your response at your earliest convenience as it affects our building permit status. Should you have any questions, please do not hesitate to contact me. Very truly yours, CCL CONSULTANTS, () ]?- ~fh F. Kolb, e.?ect Manager JFK/kag Enclosure INC. Jr., P.E. cc: Richard staudinger, City of Boynton Beach c/o Gee & Jenson Nolan Sims, Racetrac Petroleum, Inc. c:.;:::a'!i" - RECEIVED MAY J. 1 PLANNING DEPt, ..r~ t~!.fl.Hr~~Jf'<,l ";.i.\:~eH ~:fl.f-\~.~ tii\fc:~S~.]~.; i l\,~fl~:rfl. I ~:~~C. 531C ~"J ":/ ,~3(c: :\\'~."';,.,~:. ~;'" :'._; ?,>:: 0 F-:.,r' i.ill,:'-'J.::"::;.::'l'~ F (:' ~J:1 :;-~'_~,::~:!' IS/:^. (ll:~i";;; ',"~~(,.j'-),,)(-',.;" j "'!: !"Y~" ..1.t:C~ May 4, 1993 Mr, Joseph F. Kolh, Jr., P.E, CCL CONSULTANTS, INC. 2200 Park Central Boulevard, N., Suite 100 Pompano Beach, FL 33064 Re: Driveway Review RACETRAC GAS STATION Dear Joe: We have reviewed the two proposed driveways for the Racctrac Gas Station located on the southwest corner of Woolbright Road and S. W. 8th Street. Our opinion, based on our review, is that both driveways conform to Palm Beach County's minimum standards as published in Guide to Parking La( and Street Access Design Criteria and Standards. A summary of our review is provided in the following table. WOOLBRIGHT RD, D/W S,W, 8th ST. D/W CRITERIA Actual (Minimum) Actual (Minimum) Driveway lype Intermediate Minor Distance from corner 111 ft. (75 ft.) 140 ft. (50 ft.) Throat distance 80 ft. (50 ft.) 17 ft. (25 ft,)I Lane width 12+ It. (J2 ft.) 12+ It. (10 ft.) Curb radii 30 it. (35 ft. r ] 5 ft, (30 frY Lefl-turn lane None required None required Right-turn lane Provided None required Noles: 1. Minor discrepancy in ilcrual versus required not critical given the land use and site circulation, 2. Driveway width is 45 reel whic,h effectively incrc<tses radius to required length, If you have questions on this, please call us. ('~-'-) i ~,~~) PARSO!\iS ..:.:_,_.. 'rHI\i\J5POI"l'~ ,~,T;OI\i GHOUl'- CCl CONSULTANTS, INC. Consulting Engineers Surv9yors Planners 2200 PARK CENTRAL BLVD" N, SUITE 100, POMPANO BEACH, FL 33064, (305) 974-2200. FAX (305) 973-2686 FACSIMILE TRANSMITTAL DATE: 5/6/93 FROM: JOSEPH F. KOLB. JR.. P.E. PLEASE DELIVER TO: COMPANY: ,/'" Christopher cutro 1// City of Bovnton Beach NAME: FAX NUMBER: (407)738-7459 FAX OPERATOR: Kathv Gerdemann CCL PROJECT NO.: 3197 Racetrac Gas station REMARKS: cc: Richard Staudinaer (407)686-7446 Nolan Sims (404)431-7612 Number of pages including this cover sheet: 3 Upon receiving this facsimile, please do not hesitate to contact the sender or receptionist at our office if there are any pages missing or not legible. Thank you in advance. RECEIVED MAR 1 8 1993 CCl CONSULTANTS, INC. Consulting Engineers m- Surveyors ,'. Planners 2200 PARK CENTRAL BLVD" N, SUITE 100, POMPANO BEACH, FL 33064, (305) 974-2200. FAX (305) 973-2686 March 18, 1993 Mr. Christopher Cutro, Planning & Zoning Director CITY OF BOYNTON BEACH 100 E. Boynton Beach Blvd. Boynton Beach, Florida 33425-0310 RE: Racetrac Gas Service Station and Convenience Store Engineer's Project No. 3197 Dear Mr. Cutro: In response to your comments dated February 18, 1993 we have modified our plans and herein submit the following: 1. 12 sets of revised Site Plans 2. 12 sets of revised Master Engineering Plans 3. 12 sets of Building Floor Plans 4. 12 sets of Landscape Plans 5. 12 sets of Elevations 6. 9 Color Photographs showing the proposed store colors and signage 7. 1 Signed Original Application 8. 12 Surveys The following is a response to your memorandum: Dorothv Moore 1. Master Plan modification is underway. We will submit this by March 19, 1993. This will include two (2) new driveways, the size of the outparcel building, the dimension from Southwest 8th Street, the location and size of peripheral green belt and the change in traffic generation. 2. Please see revised Landscape Architect's drawings. 3. A note has been added to the Site Plan. ~'88 Mr. Max Smith C. C. L. Consultants 2200 Park Central Boulevard No. Suite 100 Pompano Beach, FL 33064 Bo.td of SupervIsors c. Stanley Weaver Kennlt Dell John I. WhItworlh ill SecNlaIyIManagw WUIIam G. WInters Aulelanl Manager Rlcta'd S. Wheellhan Allomey ~ ,0") hone. P,A. , , \....~ .:., >... ~ t"....l' :-..'" V '. ""'.Ir...,~ . ~ ~;" ...,.,~-;V.... "<- .- "'-, ..... I' t- \ ~ I:~ i " · ~ -9',..., hUJL f.u~-::;. OCT 1 9 1994 ~ " LAKE WORTH DRAINAGE DISTRICT 13081 MILITARY TRAIL OELRAY BEACH, FLORIDA 33484 October 17, 1994 ... BU1!..~ms<:' i ?" ".~. ""1 Q. . I Vr ..,l"r;....M~ """ Pi- <i-'" . r//~'O.'l JE;\l:.';\.., '. ./" " / -A Vl.' Dear Mr. Smith Subject: l WOO Permit No. 93-12070.05, Woolbright Place - Racetrack Gas Station. Since permit issuance over a year ago, the above project has generated no significant activity or construction. Please be advised that the permit is considered to have expired and prior to any future activity and or construction a new permit will be required meeting current District Policies & Guidelines. Sincerely, LAKE WORTH ORA/NAG E DISTRICT Patrick A. Martin, P.E. District Engineer PAM:mk c: William G. Winters, Manager, LWDO Shaughn J. Webb, Chief Inspector, L WDO Don Johnson, City of Boynton Beach Defray Beach & Boca Raton 4~ . BoynlDn Beach & West Palm Beach 737-3835 . FAX (407) 495-9694 a: ;, )> ,n " : .. > , ~ z ~ . I :1 I I ~~a (t~~ ,:-4 1t)C\ ~~~ flt-Qj ~~ ~ Q) ~ )> . .. <n ~ () .'\ )> . )> en !;; t- 'ji ~ {) ~ tJ] ~ ....,~ ~"\) '"0 ~ ~ N, (j) :t~ ~ UI - \Il ~~(I) m '"' <J1 ti ....... ~ ~ CO ... Jl t+ 'It t+ . . . . .. ~ ~ ii . . . , ,~ U ~~~ ~ ~ ,~, J; ., ~ C) "< 8 ~() ~ i!' to .....'1 0 ~""( .., v, ~ "'VI U\ c;" (b~);! ~ :::~ ~~ ~ U> ..C1l:li. ~ J; () () lJ\ II ~ ;t o ~ t) '. 0 ~ i\) -- lJ\ ~~ = ~ ~ I ~ ~ ~ ~ o.S ~ ~ '" ~ ~ "'- PIb a! C) !:J ~ ~ ~ ~ ~ Q ~ ~ :::::: ~ 'Wb(i)" . alf\~ ~ ~~~6 !1lbti~ ::!Oh ~~~ ~~ ~o -f1>~ tllJ S:o ~~ .&. ~ ~ i\i ~ b ~~~ !\)~ ~bj <J1 () " ti ~ . Vi CJI - w'- "b'- r-1\) l>U) (')r-- ~(:) ~. ~ ofl. '\ S ~ ... ..., ...... r~ ... 0> CJ\\n .po. W ~ n, ~ () <s1 (")0 c~ ~~ :-.. \ ~ r- 7t ~ "'< t ,- I... , \ / '- ~~ ~I;;:)~ ~~ :t;i\) " . f)~ U)~ ~ " r--UI ,...~ N ... ~~~~~~~~~=~~~~i~=~~~~~~~~ge 3~Mz~~n~~H~~ ~~ ~i~~~ ~o~~~~~sz ~ ~ ~o~o~ ~ ~~~ n~~c~t;~~~o~n~~~ 6~~o ~~ ~~~ ....==a .,,~taJ ~'"d R. . _tntDOO 5~~~~a~~~~a a~a~~B~~~e~~Q ~ r--tIl...~ a. eli:l~f:! =t;"'~'" ~f:j~~~ '!;i~e ~a' ~~~=~i~~~~!~~~~a ~~~~~ R "'I~ ","''''~...~~~~ ~ >~~M~ ~ '" c",,,,~~r--oc~ l2l' Rl:le ~a ~ ~t:!"'t3=. ~~. gH~= o ~ ~ s lila=PI~~' Q li!l":~ o a~~ a~ b ~e~' 1IO~~~~~lZ!~~ a ~~'" I~ a~!~~ PIS' 5i"'a~' PI ~ :l~~ ~ tIl~ ~~ 8~a~~r--~ ~ ~ ~~~ a NO ~~ ~"'PI~~~lZ! ~ ~ z~~ ~E g~n~~ ~~J~~a~ e ~~= ~ ~S!~~ ;B:~~~~ ~ ~ M = ~ ~N ~H ~ZH'" ~z ~ ~~~ ~~ ~. ~~~ aBB5a~~~ ~ ~ ~~ tIl ~ ~~.~ ~ ~M - ~ ~p::o l'It:! b1....~ .....e U2Z ~ ~~z iM t:! SQ~ ~ 8", o~ ~ Ii;: "'OB !il !;11j~ r-- .... ~~t:l t" o~z ~ ~ M~(") '" C ';lM a ~ ~~e ~~ s ~~~ ~ a ~:~ ~ o ~~~ ~: a ~t:l~ ~ ~~~ ~ ~ !il~ ~ e; !:l!"'~ '" E~ ~ dH ~ G\ I 0\ rtl ,[ ~ ~ ,...,...: (nCll ~ti .....:..... ,... U) IE> t-~.-1 ol T \:) till ~ffifU 103: ~ =\ 011 <? .'i Q--' '< "" ~c' .,.... ~~ -1 ~ 2~ (II ~ . '"i ~~ 0\ i\i. : ~ ~ ()) ilt 5: ~ ....fli I\) ~ ~~ ~.... l):Jn, I~i 1Il mco ~e C) ~ (.) .. .. . o ~ n . , %e City of '.Bliffnton r.Beacli P{annine & Zonine 'DepartTTUnt 100 'E. '.Boynton 'BefUh 'Boulevara P.O. '.Bo~310 '.Boynton '.Beadi, 1foritfa 33425-0310 (40i) 738.7490, 1M: (407) 738.7459 April 28, 1993 Mr. Michael Morton Tradewinds Group 902 Clint Moore Road suite 124 Boca Raton, FL 33487 Re: Racetrac Gas Service Station Dear Mr. Morton: 'fhis is to advise you that on April 20, 1993, the City Commission of Boynton Beach approved the site Plan at the above referenced location. The approval of the Site Plan was subject to the following conditions: 1. Moving the dumpster enclosure to the Northwest corner of the site; 2. Adding landscaping to the drainage area at the northwest corner of Woolbright Road and Southwest 8th street; 3. Subject to all outstanding comments from reviewing departments and attached to the city commission back-up. The Site Plan approval entitles you to develop the property as shown on the approved plans. If you wish to modify the plan prior to submission of your building plan, please contact the Planning and Zoning Department. Modifications during the building permit process will be handled as part of that process. The approval of the Site Plan remains in effect for one year, until April 20, 1994. If an extension is needed, please forward your request to the planning and Zoning Department 30 days prior to the expiration date. We have attached a list of submittal documents from the Building Department to assist you in assembling your building permit package. We have also attached copies of the comments that must be met in the building permit submittal. MEMORANDUM TO: Christopher cutro, Planning and zoning Director FROM: Dorothy Moore, Zoning and site Reviewer DA'l'E : March 26, 1993 RE: site Plan Project: Review - New site Plan Racetrac Gas Service Station and Convenience Store NW corner of SW 8th Street and Woolbright Road at Shoppes of Woolbright, P.C.D. Racetrac Petroleum, Inc. 724 Location: Applicant: File No.: The amended plans for the above referenced proj ect have been submi tted and reviewed. 'rhe comments from the original set of comments have been satisfactorily corrected on the amended plans. The applicant shall submit working drawings for permit review that depict the project in compliance with the City of Boynton Beach Code of Ordinances and the following comments. This project is being reviewed as a separate owned parcel of the existing 'fract "BlI of the Shoppes of Woolbright, P.C.D. The permit plans shall depict the site as shown on the approved master plan for the shoppes of Woolbright, P.C.D. 1. On the Landscape Plan where the trees/palms symbol is shown provide a typical dimension and note showing that the required perimeter trees are spaced forty (40) feet on center. (Trunk to trunk) /' 2. 'rhe service station shall Environmental Review Permit as 4.N. Performance standards, hazardous waste. be required to obtain an per Appendix A-Zoning, Section 11. Hazardous materials and 3. This project was reviewed under the 1986 code of Ordinances, City of Boynton Beach, Appendix A-Zoning, Section 11.L, service stations with or without major repairs. The following comments individually address eight (8) sections of section 11.L. (See the attached Section 11.L of the Zoning Code) 1. The location of this proposed service station will be located within the minimum distance requirements of one- thousand (1,000) feet of the master plan approved and platted church property. This needs to be resolved by the City Attorney. 2. Consistent with code. 3 . Consistent with code. 4. Consistent with code. 5. Consistent with code. 6. N/A 7. No longer required. 8. N/A To: Christopher cutro Re: Racetrac Gas Service Station page Two 14. The following is a compilation of the deficiencies in the submittal using the submission requirements as a comparison (See attached Section 7). Section 7. Submission requirements. 7.1 Existing site characteristics map (survey): O.K. 7.2 Site Development Plan. 2.1 The dimensions and setbacks for the proposed structures as shown on the plans are not correct. Please provide no less than the following setbacks as shown on the approved master plan for Tract "BlI East side - 40 feet Note: Canopies were not addressed in the (1986) Appendix A-Zoning Code, Section 11.L. Service Stations with or without major repairs. However, canopies are addressed in the current development standards for commercial establishments engaged in the sale of gasoline, specifically: L. Commercial establishments engaged in the retail sale of gasoline or gasoline products: (e) setbacks. (4) Other: (a) No canopy shall be located less than twenty (20) feet from any property line. 2.2 Back-up distance for the proposed off-street parking spaces is not correct. The correct back-up dimension is 27 feet for 900 parking spaces. Provide and dimension on the plans the width of the on-site traffic aisles. Provide dimensioned drawings for the dumpster (inside clearance including gates to be ten feet). 2.3 O.K. 2.4 O.K. 2.5 O.K. 7.3 Landscape plan. 3.1 See comment no. 1 above (landscape comments) 3.2 O.K. 3.3. O.K. Mr. Christopher Cutro March 18, 1993 page two Dorothy Moore (continued) 4. Please see Landscape Architect's drawings. 5. Please see Landscape Architect's drawings. 6. Please see Landscape Architect's drawings. 7. Please see Landscape Architect's drawings. 8. Please see Landscape Architect's drawings. 9. Please see Landscape Architect's drawings. to. The parking space calculations have been modified. Please see Site Plan. 11. Sheet #5 of the Site Plan Review Application has been included. 12. Acknowledged. 13 b. c. d. e. f. g. h. 14 a. b. c. a. We believe that this item is not enforceable since the church is not existing. Please notify us if additional information is required for this item. Acknowledged. Please see Landscape Architect's drawings. Acknowledged. The dimensions of the proposed driveway entrances are shown on the plans. Acknowledged. The perimeter buffer will be provided on the remaining portion of Parcel B. Acknowledged. We have included 3 sets of the Certified Topographic Survey. A Master Plan will be modified to allow setbacks shown on the Site Plan. Horizontal control dimensions for each driveway from the intersection of Southwest 8th Street and Woolbright Road have been provided. In addition, we have provided dimensions of the driveways, the back up distances for the proposed off-site parking spaces and the width of the on-site traffic isles. We have also shown all proposed pavement markings. d. The method of irrigation is shown on the Landscape Architect's plans. e. The building floor plans have been provided. The photographs show the color choices. CCl CONSULTANTS, INC. Mr. Christopher Cutro March 18, 1993 page three Dorothy Moore (continued) 14 e. f. A tabular site data is provided on the Site Plan. A Drainage Plan is provided as part of the Master Engineering Plan. FUchard Staudinger 1. Referenced in Mr. Staudinger's Memo is the current code and not the 1986 Code which is the standard for the development of this parcel. In the 1986 Code the 180 foot dimension referenced in Mr. Staudinger's Memo is not a requirement. The plan as submitted meets the 1986 Code. 2. A South Florida Water Management Permit for this area requires that one 1/2 inch pre-treatment be provided for a commercial development. The balance of the water quality treatment is provided within the lake. The comment regarding the inlet situated at Southwest 8th Street is not relevant since it's part of the overall water management system. If the City desires, we agree to a condition of the approval such that the applicable portions of the Southwest 8th Street drainage and retention system be approved by the City prior to connection of this portion of the development. 3. The Master Plan will be modified along with this Site Plan. William D. Cavanaugh A right turn lane is being provided as part of this development into the project off of Woolbright Road. We feel that this enhances the ability for emergency vehicles to enter and exit the property. Donald I. Thrasher 1. Enter/Exit signage, stop bars and turn arrows are provided for the entrance onto Southwest 8th Street. Please see the revised Site Plan. 2. A note regarding the lighting is provided on the Site Plan. John Wildner No issues were cited. CCl CONSULTANTS, INC. To: Christopher cutro ke: Racetrac Gas Service station Page Three 7.4 Architectural plan. 4.1 O.K. 4.2 O.K. 7.5 O.K. 7.6 O.K. Submit colored elevation view drawings of each side of all buildings and signage associated with the project. The applicable exterior surfaces shall be identified with the color name and associated color reference number. The type of exterior surface material shall be identified next to the associated color._ Submit color samples as an example of the proposed colors. Each" sample shall have attached a label that identifies the color by name and numerical/letter code from an established color chart. ~~ Dorothy Moore DM:ald C:RACETRAC.ALD 8ec.ll BOYNTON BEACH CODE L. SERVICE STATIONS WITH OR WITHOUT MAJOR RE- PAIRS. The following regulations shall apply to all service sta- tions constructed on or after January 1, 1983. Where an existing service station is modified in any way, the building official, tech- nical review board, planning and zoning board, and/or city coun- cil may impose any or all of the following regulations where doing so would create significant benefits to the public safety and welfare, and where the standards contained in the following reg- ulations could be reasonably accommodated on the existing site. 1. There shall be a minimum distance of one thousand (1,000) feet between the nearest property line of the lot or plot of land upon which the proposed service station is to be con- structed, and the nearest property line of a lot or plot of land upon which any other gasoline service station, church, public playground, hospital, public school or other similar public or semipublic place where large numbers of people congregate, is located. Such distance shall be by direct airline measurement. 2. The minimum size plot of land shall be seventeen thousand five hundred (17,500) feet in area with a minimum frontage of one hundred seventy-five (175) feet, on all abutting streets. Supp. No. 13 1950 APPENDIX A-ZONING See, 11 3. At least ten (10) percent of the gross plot area shall consist of landscaping equipped with adequate sprinkle systems of which at least five (5) percent shall be adjacent to the public right-of-way. All landscaping shall be maintained in a healthy growing condition. 4. There shall be a minimum distance of fifteen (15) feet be- tween the location of a gas pump island and any adjacent property line. 5. Driveway entrances shall measure no more than forty-five (45) feet across and be located no closer than forty (40) feet to any street intersection or nearer than twenty-five (25) feet to any interior property line. 6. There shall be constructed a safety island of grass or con- crete for pedestrians between two (2) driveways which shall be ten (10) feet in width and no less than twenty (20) feet in length measured along its side abutting a sidewalk or paving of said station, whichever is in the plan of construc- tion. 7. A masonry or concrete louver wall at least five (5) feet in height and meeting the provisions of the building code shall be constructed along all property lines abutting residen- tially zoned property to a distance of twenty-five (25) feet of any street right-oC.way line. The wall shall be kept in good repair and appearance at all times. Openings with gates may be allowed where deemed reasonable by the building official. 8. The entrance to the building wherein motor vehicles are washed by mechanical means as a primary function, shall be located on a lot or plat a minimum distance of seventy- five (75) feet from the street line to provide an ofT-street area for waiting vehicles. PUBLIC WORKS DEPARTMENT MEMORANDUM #93-071 TO: Christohper Cutro, Planning & Zoning Director FROM: Robert Eichorst, Public Works Director SUBJ: Second Review - Site Plan - Racetrac Gas Service Station DATE: March 22, 1993 The dumpster location at the above site is unacceptable as it is presently blocking the ingress and egress at the site. ~~~ I ,Rebert Eichorst Public Works Director RE/cr P '\-, ,r--"-,, I fr t I ., .~ o. .. ..~. . J ,. l .,'-' ~ ....".,'. . ~ " . ',),' " '.;,{ ittl/J ~';g ',I:':;~ ; . ~ .. , " J~ ......,.. "'1) i\ / \ GEE & JENSON Englneers-Archltects.Planners, Inc ,/ , '" One Harvard Circle West Palm Beach, FL 33409 Telephone (407) 683-3301 Fax (407)686-7446 \; MEMORANDUM TO: Christoper Cutro Planning & Zoning Director FROM: W. Richard Staudinger, PE City Engineer DATE: April 5, 1993 RE: Site Plan - Second Review Racetrac Gas Service Station Our review of the referenced Site Plan has resulted in the following comments: 1. Dry pretreatment of stormwater from this site is required by City Codes, which may be more stringent than the SFWM permit for this area. The original comment stands. 2. Driveway widths exceed City Standards. 3. Traffic study is required to assess impact of driveway and use on the intersection of SW 8th & Woolbright Road. ~~~)4/~ W. Richard Staudinger, PE City Engineer RECEIVED APR 0 5 1993 BUILDING DEPARTMENT MEMORANDUM NO. 93-067 March 25, 1993 To: Chris Cutro Planning Director OffiCial!)-- Thru: Don Jaeger, Building From: Al Newbold Deputy Building Official RE: TRC COMMENTS - RACETRAC GAS SERVICE STATION The Building Department has reviewed the above referenced resubmitted plans. We have found that the response to #1 of our first review is in compliance with Appendix A, section II, E. 4(A) setback of a 20' minimum for the canopy; however, not with the required setback for PCD zoning of the 30' side yard, and the 40' front and rear yard requirements. Please see #2 of memorandum #93-042. Please note that the setback for the canopy is from the edge of the canopy, and no structure can be permitted within an easement. We still require a response to #3, #5, and #6, with relocation of the 12' easement, prior to our recommendation for forwarding this project to the Planning Development Board, etc. AN:fs RACETRAC RECE\\IEO MAR 'i. b \993 BUILDING DEPARTMENT MEMORANDUM NO. 93-042 February 19, 1993 FROM: Chris Cutro Planning D~'r cto,r Don Jaeger Building 0 cial Al Newbold Deputy Building Official TO: THRU: RE: TRC COMMENTS - RACETRAC GAS SERVICE STATION The Building Department has the following comments which need to be addressed before a permit can be issued for the above referenced project: 1. All setback dimensions must be shown on the site plan. 2. Setbacks from both S.W. 8th Street and Woolbright Road are required to be a minimum of 40' and a peripheral greenbelt is required on all sides in order to comply with Appendix A, Section 6.F.7. (Design Criteria for PCD District). 3. A sign program, per Chapter 21 of the Code of Ordinances, is required, showing all signs in compliance with the same, including the number of signs, height, type and size. 4. Submit a floor plan of the building and show the elevation of the canopy and its height above fire lanes. 5. Please state on the plans how you will finish the remaining portions of Tract B. 6. Show on the plans a detail of the handicap curb cut or ramp from the handicap space to the store and from the public street to the store, per the State Handicap Code. Please note that all building code requirements must comply with the code in effect at the time of permitting, per a legal opinion from our City Attorney. iJ~ A New old AN: bh RECEIVED FEB 2 2 1993 RACETRAC MEMORANDUM Utilities #93-130 FROM: Chris Cutro, Planning & Zoning Director John A. Guidry, ~ ~~ Director of Utilities ~~~ - r-cv- o/~ TO: DATE: March 25, 1993 SUBJECT: RaceTrac Gas Service Station New Site Plan - Second Review File 724 Staff has reviewed the plan and are unable to recommend it moving forw~rd due to the following: 1. Previous note #1, Utility memorandum 93-073, has not been rectified. Staff has contacted Mr. Kolb with CCL, as requested in his March 18, 1993 letter, and explained that the gravity sewer under the proposed service road has not been constructed nor is it presently permitted. 2. Previous note #5, Utility memorandum 93-073, has not been rectified. Staff has contacted Mr. Kolb with CeL, as requested in his March 18, 1993 letter, and explained that the Lift Station 608 and 609 reroute, dated January 1990, although permitted, has never been constructed. Until this reroute is complete, the force main across RaceTrac is active. Since the reroute was a condition of the overall D.C.D. approval, we will not entertain the suggestion of rerouting this active force main around the site. The remaining comments, No.s 2 through 4, 6 and 7, have been addressed sufficiently by the consultant's letter of March 18, 1993, and can be monitored at time of building permit issuance once the site plan is approved. 19b xc: Mike Kazunas Mark Law Peter Mazzella Skip Milor File Utility Engineer - 2 hours Admin. Assistant - .5 hour RECEIVED MAR 2 6 1993 ~ MEMORANDUM Utilities #93-073 TO: Chris Cutro, Planning and FROM: John Guidry, Director of Utilities DATE: February 23, 1993 SUBJECT: Racetrac Gas Service Station New Site Plan - First Review File 724 Staff has reviewed the plan and offer the following comments: 1. The sanitary sewer shown is a dry line sewer which is not connected into our system. 2. All utilities must be within right of way or easement Section 23-33(a). Replat may be requi~ed. 3. A survey shall be submitted showing existing utility easements. Site plan review, Ch.4, Section 7.1.3. 4. Potable water shall not be used for irrigation. Irrigation meter shall be deleted (City of Boynton Beach Comprehensive Plan Policy - 3C.3.4). 5. An active force main runs across the site. As a condition of master plan approval, this force main was to be abandoned. A letter of credit to perform this relocation off site was secured. This work must be performed concurrent with this project. 6. A tee, a restrained gate valve, and a plug must be provided for future service of the remainder of tract "B" Section 26-16(a). 7. Reduced pressure backflow prevention is required on building uses of this type (Ord. 90-11) 19b xc: Mike Kazunas Mark Law Peter Mazzella Skip Milor File Utility Engineer - 2 hours Admin. Assistant - .5 hour RECEIVED FE B 2 :l 1993 Mr. Christopher Cutro March 18, 1993 page four Kevin J. Hallahan No comments pending. John Guidry 1. We believe that the Sanitary Sewer System that this project will connect to is not a dry line. Please contact us regarding this. 2. Our Client proposes to submit Utility Easements for the proposed utilities which are outside existing easements. These will be prepared after the completion, but prior to the acceptance by the City. This can be done by a separate instrument and will not require replatting. 3. A existing Topographic Plan has been provided. 4. We have deleted the irrigation meter from the plans. 5. I believe that the force main that used to run through the site has been abandoned. This was done as part of the Home Depot development. Please notify us if this is inaccurate. 6. A Tee, a restraint gate valve and a plug will be provided for future service to the remaining Tract B. 7. A reduced pressure back flow preventer will be provided for this building. I believe that this adequately addresses all of your comments. Should you have any further questions, please do not hesitate to contact me. Very truly yours, CCL CONSULTANTS, INC. JFK:kk enclosures CCl CONSULTANTS, INC. PLANNING AND ZONING DEPARTMENT MEMORANDUM NO. 93-072 TO: J. Scott Miller, City Manager ~b~ FROM: Christopher Cutro, Planning and Zoning Director DATE: April 16, 1993 SUBJECT: Racetrac Convenience Store/Gasoline Sales CCL Consultants, representing Racetrac Gasoline, has filed for a site plan review for a convenience store with 12 gas pumps at the northwest corner of Woolbright Road and southwest 8th Street. This site is an outparcel of Parcel B in the Shoppes of Woolbright PCD. The site would contain a 3040 square foot convenience store with 12 gas pumps. The proposed development meets the overlay zoning for gasoline sales that was applicable in 1986 and some sections of the ordinance adopted in 1992. The Planning and Development Board reviewed this site plan and forwarded it to the City Commission with a recommendation for approval. This request has been scheduled for review and consideration by the City Commission at its meeting of April 20th, 1993. CC/cmc C:Racetrac r~ .n GEE & JENSON Englneers-Architects-Planners, Inc, One Harvard Circle West Palm Beach, FL 33409 Telephone (407) 683-3301 Fax (407) 686-7446 May 12, 1993 Mr. J. Scott Miller City of Boynton Beach 100 E. Boynton Beach Blvd. PO Box 310 Boynton Beach, FL 33425-0310 Re: Tradewinds Lake Excavation Racetrac Gas Station Dear Scott, As a result of our on-site meeting with Mr. Morton yesterday, he will level out and seed and mulch the large sand stockpile on the north side of the pond. Once this action is completed, he is requesting we review the permit plans for the Racetrac Gas Station at SW 8th and Woolbright Road. At the City Commission and Planning and Development Board meetings I was directed not to approve the permit plans for this project, which utilizes the lake for retention, until the lake problem with blowing sand was fixed. This letter is my request that this matter be placed on the agenda of the May 18, 1993 City Commission meeting for discussion. I believe it is appropriate that the Commission concur with staffs/action in this matter. WRSfjer 92025/200 ~ RECEIVED cc: . James Cherof Don Jaeger Chris Cutro Mike Sewell MAY 1 4 PLANNING DEPT. I ., ::...... - . \',- .. .~ ! i . {", : '- J, ;. . ' : },!' '; , . '" \1\" n l-'! r, .' j'l~1 ' h.l i..:,> ',i j ~ ,.' i~ "'~",.t.~. J ,I...:' ~.~.\ '\ , GEE & JENSON f-uJ,l ""I Englneers-Architects-Planners. Inc 1\ ' '1/',.; r ....:....-;:;. One Harvard Circle West Palm Beach, FL 33409 Telephone (407) 683-3301 Fax (407)686-7446 May 10, 1993 Mr. Joseph F. Kolb, Jr., PE CCI Consultants, Inc. 2200 Park Central Blvd. North Suite 100 Pompano Beach, FL 33064 Re: Racetrac Petroleum Entrance Drive Widths Dear Mr. Kolb: I am in receipt of your letter dated March 31, 1993 requesting two (2) 45 foot wide entrance drives for the referenced project: No supporting data, such as truck routing, tank fill locations, etc. was supplied. I certainly concur that the entrance drive off Woolbright Road will be used for gasoline deliveries to the station and is therefore justified to be 45 feet in width. However, the entrance drive off SW 8th does not appear to be readily accessible to trucks as SW 8th is a divided roadway that dead-ends just north of the proposed station site in a manner which would not allow a U-turn by a gasoline tanker. I suggest you reduce the entrance drive on SW 8th to the 32 foot maximum in the parking lot code or provide backup material to justify a wider entrance drive. (e v W. Ricliard taudinger, P.E. City Engineer 92025 WRS/jer cc: Chris Cutro Vince Finizio J. Scott Miller CCl CONSULTANTS, INC. Consulting Engineers Surveyors Planners 2200 PARK CENTRAL BLVD.. N, SUITE 100, POMPANO BEACH. Fl33064, (305) 974-22~. FAX (305) 973-2686 March 31, 1993 Mr. Richard staudinger, P.E. City Engineer City of Boynton Beach 100 E. Boynton Bch. Blvd. P. o. Box 310 Boynton Beach, Florida 33425-0310 RE: Racetrac Petroleum Engineer's Project No. 3197 Dear Mr. Staudinger: On behalf of our client, Racetrac Petroleum, Inc., we request that the entrance drives to the project from Woolbright Road and from S.W. 8th street be 45' in width each. This is to accommodate the delivery trucks in and out of the site. Proper signing and striping will be provided with the final engineering drawings. Should you have any questions, please do not hesitate to contact me. Very truly yours, CCL Consultants, Inc. '7~ h F. Kolb, Jr., P.E. ect Manager JFKjkag cc: Nolan Sims, Racetrac Petroleum, Inc. U4/UlII:IJ UI:I:17 '0"305 In J ~b1ib eeL eONSULTAi\TS ~001 *****....**..............s. *** ACTIVITY REPORT .~:* ******..................sss TRANSMISSION OK TXlRX NO. CONNECTION TEL CONNECTION ID START TIME USAGE TIME 9849 14076867446 0410109:17 00'37 PAGES RESULT 1 OK Post-It'" brand fax transmittal memo 7671 # of pages . To . From Co. Dept. ~ "- n GEE & JENSON MEMORANDUM TO: FROM: RE: DATE: May 11, 1993 **************************************************************************************************** The analysis by Barton - Aschman attached to the May 06, 1993 letter for CCl does not meet the requirements of the intersection analysis requested during site plan approval. In addition I have questioned the need for a 45 foot wide driveway on SW 8th Street. That may affect Mr. Fernandez's note number 2 pertaining to substandard radii. I specifically need an intersection analysis detailing turn and through traffic before and after the siting of the gas station. :jer 92025/21 0 O-t,t 1/(_ ~J~ ~t~ Al4r t /') CCl CONSULTANTS, INC/./99J Consulting Engineers Surveyors Planners 2200 PARK CENTRAL BLVD., N, SUITE 100, POMPANO BEACH, FL 33064, (305) 974-2200. FAX (305) 973-2686 May 6, 1993 Mr. Christopher Cutro, Planning & Zoning Director CITY OF BOYNTON BEACH lOO E. Boynton Beach Blvd. Boynton Beach, Florida 33425-0310 RE: Racetrac Gas station Engineer's Project No. 3197 Dear Mr. Cutro: On behalf of our client, Racetrac Petroleum, Inc., we are SUbmitting a letter from Barton-Aschman addressing the traffic related issues brought forth during our recent site plan - approval. By copy of this letter, I am also SUbmitting this to Richard Staudinger for his review. Please provide your response at your earliest convenience as it affects our building permit status. Should you have any questions, please do not hesitate to contact me. Very truly yours, CCL CONSUL~ANTS, U7? ~fh F. Kolb, ~ect Manager JFK/kag Enclosure INC. Jr., P.E. cc: Richard Staudinger, City of ;Boynton Beach c/o Gee & Jenson Nolan S~ms, Racetrac Petroleum, Inc. ~lI'U~' ,"~~)~\~ ~li.\dt.~:'-S ~~:f.ch\~.' i\~~~~,jj~~i i\T"":~El, ;f"'f.~. -;a._._-_._--~"-"-'--- .,. _.. .-.--.--,.....- -.. .......- .-". :jj 1 C ~~J ~: / . ~ 3r (: :~,\':-"''''' .,~.' ";'_ ~,_:'; ;let C) f" ;Y' :.;1I.':~C~I:::: ;t\ F ~'," ~j.:1 :;"J .<:~.' l. I~; ~. 0 I ::I';'-~; ... .":'0', - j .'~, "." . . ~. 5.' ~ t <. May 4, 1993 Mr. Joseph F. Kolh, Jr., r.E, CCL CONSULTANTS, INC. . 2200 Park Central Boulevard, N., Suite 100 Pompano Beach. FL 33064 Re: Driveway Review RACETRAC GAS STATION Dear Joe: We have reviewed the two proposed driveways for the Racctrac Gas Station lot<:lted on the southwest corner of Woolbright Road and S.W. 81h Street Our opinion, based on our review, is that both driveways conform to Palm Beach County's minimum standards as published in Guide CO Porking Lac and Street Access Design Cn',cria and Stalldards. A summary of our review is provided in the following table, WOOLBRIGHT RD. D/W S. W, 8th ST. D/W CRITERIA Actual (Minimum) Actual (Minimum) Driveway lype Intermediate Minor Distance fwm corner 111 it. (75 ft.) 140 ft. (50 ft.) Throat distance 80 f1. (50 ft.) 17 ft. (25 ft.) 1 Lane width 12+ ft. (12 ft) 12+ CL (10 [1.) Curb radii 30 ft. (35 f1.)2 ] 5 ft. (30 flY Left-turn lane None required None required Righl-turn lane Provided None required Noles: 1. Minor discrepam:y in actual versus required nOl critical given the land use and Slle circuliition. 2. Driveway width is 4S feel which effectively incrc<<ses radius LO required length. ~ If you have questions on this, please call us. (;:;:-;-) ;;~-':JJ PAnSONS '. "___" '..HAf\JSJ.1C.jr=--.: 1~.TH~)r~ Of.l0!JJ.=' 04/12/93 14:12 f!'305 973 2686 CCl CONSULTANTS IaJ 0021003 Barton-Aschman Associates, Inc. 5310 N.W. 33rd Avenue, SUite 2OC5 Fort Lauderdale. Florida 33:308 USA March 29, 1993 Phone: (305) ~-4220 Fax: (30S) ~3-4B6S Dads; (305) 881..0552 Mr. Joseph F. Kolb, Jr., P.E. CCL CONSULTANTS, INC 2200 Park Cenual Boulevard, N.. Suite 100 Pompano Beach, F1.. 33064 JJ"'jIJ1t" ".-.- . '...:'.'. i'q~'u, .--" ".~ ~,.~.....~ .,...J ....,....-... Re: Proposed Raoetl'ac Gas Station WOOLBRIGHT PLACE PCD !~: ~ ~ 'to.- ---,' ....--.......---..--.. Dear Joe: We have completed OUT trip generation a~is for the above-referenced development. The purpose of this study wa5 to determine the amount of retaiJ/cOnunerdal square footage that will have to be reduced from the approved pen \0 accommodate the proposed gas station and convenience store. CONCLUSION Tbe gas 8tatioJ:l/convenience store will generate 121.5 net daily trips. To aca>mmodate these trips, the commercial/retail development program (or the peD will have to be reduced by 32,000 squalC feet. Our conclusion was based on the following analysis. ANALYSIS Out conclusion wag b~ed on dividing the trips generated by the proposed gas station/convenience store by the QOQ.'lmeraallret2i1 trip seneration rate documented in the JanuaIY 1990 traffic impact report for the Woolbright Place PUD,iPCO. The analysis steps were as follows. 1. The gu statianlmRvenience store trip generation analysis was based on the procedures listed in the Palm Beach County und Development Code (See. 10.8), and was calculated as follows: LANO.USE Gas Station TRIP QUANTITY RATE 1 lNTERNAL NET TRIPS TRIPS 314 901 1215 Convenlc.nc;.c Sto-ro 3.040 s.f. \ ",- -..... 0~ d; r ::~~ /1 (j , i \ d. ,', \'1.'/ --.'.. ~,~/ ~. '-;7 o (6J ) J I - /7.-- ~- ~~. .' ~","" hzr; - ,/ 04112/93 14: 12 'fS'305 973 2686 eeL CONSULTANTS 14l003/003 '.' .arton-AlIChman Associates, Inc. Mr. Joseph F. KOIb, Jr., r.B. Marcn 29,1993 Page 2 2. The VC8ted daily Uips fOJ the approved d~lopment program arc 11,$94 (Home Depot (102.,2S0 d.): 3.404; CommerctaJ.l'Rctail (Z15.7S0 5.f.): 8,189). ThCiICI WCIC'; buc.d OQ TtrIf!ic Impact Analym: Woolbl1gtu rtace PUD/PCD. Banoll-A5Qu:Dan AModa1C5. Inc.. January 23,1990 (Table Z. p.2). The trip rate tor the CDmmerda~laD. based OD the dted uaffk; impaet analysi! is 37.95 trips/kSf. 3. The most recent proposed development program alI:i for the development of 2IY7.750 square teet of CQmmcrdaVrctail. providing for II ~ trip a-c:dit (215.750 .207.750 = 8.000 ksf lC 37.95 tripslk3f = 304 trip). 3. Thc diffc.IaI.CI:: between the trip:s generated by the &as ~tadoD/ronvcnicnce :store and the cr<:dit trip& (1t215 _ 304 = 911). rcpn:scDm the trips gcncrat(;(l by the amount of oolllMCrdatlreuil that mu:sl be made up by further dc:t;ICaliing the: tnmmel"Cial/retail dC1'elopmcnL The quantity of thi:i development is the qUOtiCDt of these trips and the commercial/retail trip ,gerlcratiot:l (911 trips / 37.95 lripB/ksf = 24.000 ~ uarc feet). Plcll.!iC let us knoW' if you hil~ any qUC3tiOn.l or comments on this. ~1... ~ APPENDIX A-ZONING See, 11 3. At least ten (10) percent of the gross plot area shall consist of landscaping equipped with adequate sprinkle systems of which at least five (5) percent shall be adjacent to the public right.of-way. All landscaping shall be maintained in a healthy growing condition. 4. There shall be a minimum distance of fifteen (15) feet be- tween the location of a gas pump island and any adjacent property line. 5. Driveway entrances shall measure no more than forty-five (45) feet across and be located no closer than forty (40) feet to any street intersection or nearer than twenty-five (25) feet to any interior property line. 6. There shall be constructed a safety island of grass or con. crete for pedestrians between two (2) driveways which shall be ten (10) feet in width and no less than twenty (20) feet in length measured along its side abutting a sidewalk or paving of said station, whichever is in the plan of construc- tion. 7. A masonry or concrete louver wall at least five (5) feet in height and meeting the provisions of the building code shall be constructed along all property lines abutting residen- tially zoned property to a distance of twenty-five (25) feet of any street right-of-way line. The wall shall be kept in good repair and appearance at all times. Openings with gates may be allowed where deemed reasonable by the building official. 8. The entrance to the building wherein motor vehicles are washed by mechanical means as a primary function, shall be located on a lot or plat a minimum distance of seventy- five (75) feet from the street line to provide an off-street area for waiting vehicles. BUILDING DEPARTMENT MEMORANDUM NO. 93-042 February 19, 1993 FROM: Chris Cutro Planning D~'r ctor Don Jaeger ' Building 0 cial Al Newbold Deputy Building Official TO: THRU: RE: TRC COMMENTS - RACETRAC GAS SERVICE STATION The Building Department has the following comments which need to be addressed before a permit can be issued for the above referenced project: 1. All setback dimensions must be shown on the site plan. 2. Setbacks from both S.W. 8th Street and Woolbright Road are required to be a minimum of 40' and a peripheral greenbelt is required on all sides in order to comply with Appendix A, Section 6.F.7. (Design Criteria for PCD District). 3. A sign program, per Chapter 21 of the Code of Ordinances, is required, showing all signs in compliance with the same, including the number of signs, height, type and size. 4. Submit a floor plan of the building and show the elevation of the canopy and its height above fire lanes. 5. Please state on the plans how you will finish the remaining portions of Tract B. 6. Show on the plans a detail of the handicap curb cut or ramp from the handicap space to the store and from the public street to the store, per the State Handicap Code. Please note that all building code requirements must comply with the code in effect at the time of permitting, per a legal opinion from our City Attorney. ~(~ A New old AN: bh RECEIVED FEB 2 2 1993 RACETRAC --------- ' MEMORANDUM Utilities #93-158 TO: Chris Cutro, Planning and DATE: Apr i I 13, 1993 FROM: John A. Guidry, Director of Utilities SUBJECT: RaceTrac Gas Service Station New Site Plan - Second Review File 724 Supplemental Comments to Utility Memo 93-130 The applicant has provided this utility a letter acknowledging the need for the relocation of the force main and completion of the gravity sewer prior to the issuance of any building permits (see attached). With this understanding, the Utility Department is willing to recommend this project move forward through the plan review process. 19b Attachment xc: Mike Kazunas Mark Law Peter Mazzella Skip Milar File RECEt~,T~D APR 1 3 1993 : :, ~ :00 tECH =~ , - ,__ 1--.>.....,.>--'- -'__'__":::'" April 9, 1993 Mr. Chris Cutro City of Boynton Beach 100 E. Boynton Beach Blvd. P.O. Box 310 Boynton Beach, Florida 33425-0310 RE: Racetrac Petroleum Site at Woolbright Road Dear Mr. Cutto: PIC;;1!e accept th.l! letter as an Agreement that the above-referenced Site will continue with the Site Plan Review. It is understood that the Building Permit will no~ be issued until such time as the Forced Main crossing our Site is relocated and that the Gravity Service Line is in operation and accepted by th~ City of Boynton Beach. According to plans approved in 1990. If you have any questions, please feel free to contact me at (404) 431-7600, ext. 1125. Sincerely, N~~ Nolan Sims Qf Project Manager enclosures cc: I]ohn Guidty. Boynton B=lch Utilities Joe Kolb, CCL Consultants Mike Morton RACETRAC,PETROLEUM. INC. P.O. Box 105035, Atlanta, Georgia 30348..5035 (404) 431.7600 - ~.-.. , I I thJL P",<;: -\ l'i ('~,. ~.l. ~ f rs: .i- f~~ (.....,1,-_..10_1 n GEE & JENSON GEE & JENSON MEMORANDUM Engineers-Architects-Planners, Inc, RE: One Harvard Circle West Palm Beach, FL 33409 Telephone (407) 683-3301 Fax (407) 686-7446 TO: FROM: DATE: April 23, 1993 I have reviewed the March 29, 1993 Trip Generation Analysis submitted by the applicant addressing the reduction in commercial square footage resulting from the modification of PCD uses to include a gas station and convenience store at SW 8th & Woolbright Road within The Woolbright Place PCD. My review included coordination with Mr. Dan Weisberg of Palm Beach County concerning the appropriate trip generation rates, pass by trips & internal trip credits for the gas station/convenience store. I do concur that the addition of the Gas Station and 3040 SF Convenience Store and the reduction of commercial square footage to 28,000 SF will not result in a net increase in trip generation for Parcel B of the PCD. ~ .... However, to date I have received no study or analysis of the impact of the Gas Station/Convenience Store on the intersection of SW 8th & Woolbright Road. This study is requested in my TRC comments. It is necessary to determine the effect of the proposed driveway and related turn movements on the subject intersection, and remains and outstanding comment on the Master Plan Modification and on the Site Plan. 92025/210 WRSfJer cc: Vince Finizio J. s.cott Miller Mike Hang '.-.. RECEIVED APR 2 3 1993