REVIEW COMMENTS
MEMORANDUM
TO
Carmen Annunziato
Planning Director
DATE
January 7, 1987
FILE
FItOM
Kevin J. Hallahan
Forester/Horticulturist
5UB.JI:CT
Girtman Child Care Center
Conditional Use Modification
This memorandum is in reference to the landscape plan sub-
mitted for the above project. The applicant should address
the following:
1. There should be a notation as to the type of sod and
automatic irrigation system to be installed.
2. The landscape plan does not meet the requirements of the
revised "Boynton Beach Comprehensive Plan Addendum,
November 19, 1986~, pg. 4,5. The applicant should
make these changes in his landscape plan.
5t~-_./~. .J-I#LL~
Kevin J. allahan
KJH:ad
M E M 0 RAN DUM
January 7, 1987
TO: Mr. Jim Golden
Planning Department
FROM: Tom Clark
City Engineer
RE: Girtman Child Care Center
Comments:
I. Signs and pavement marking to be according to MOUTCD.
2. See memo from Bill Flushing dated January 2, 1987.
-y~~
Tom Clark
TAC/ck
Attach.
.....1...........~"..,..."M..........Q,",...,,,..B...."...m.f.?L...,.J~_....._.m.~~.'_""._.~"._",.M.
January b, i987 (Tuesday)
TO:
Tom Clark
FROM:
Bill Flushing
RE:
Girtman Child Care Center.
The following discrepancies should be noted:
1 .
Extruded curb must be a minimum of 6" x
1"7
~,
1/2".
"
L.
Sidewalk
egress.
to
run
through
parking lot ingress and
"7
..,:r .
A detail is
on the west
required for the swale retention area
side of the building.
J14/f1vJ~
Bill Flushing
i
CITY OF BOYNTON BEACH
MEMORANDUM
To:
CarMen Annunziat.o., Planning
Direct.or t~
Utilitie~
FroPl:
John A. Guidry, Director of
Dat.p.: January 5, 19B7
Subject: TRS Review - GirtPlan Child Care Center
We can approve this plan subject. to the following conditions:
1. Specify the PliniJ'lluPl distance of the water Plain froPl the building.
2. On the sanitary service. specify a J'IIiniPluJ'II 1% slope. VCP cleanouts
at the property line, if lacking, cleanout at five (5) feet froPl
the building. and Platerials used in construction.
3. Add a fire hydrant aS5ePlbly to be within 200 feet of the furthest
point on the building.
4. Provide a detail of the stucco buffer wall adj oining and crossing
the water Plain.
5. Provide an easeJ'llent for existing 4" water Plain.
dPlt